Extron XPA 2004 Manual

XTRA

Full Rack Series:

XPA 2002-70V XPA 2002-100V XPA 2003C-70V XPA 2003C-100V XPA 2004 XPA 4002 XPA 4002-70V

Full-Rack 2-, 3-, and 4-Channel Mono and Stereo Audio Power Amplifiers

User Guide

Audio Products

68-783-01 Rev. E 0 1 1 9

Safety Instructions

Safety Instructions • English

WARNING: intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.

This symbol, ,when used on the product, is ATTENTION: This symbol, , when used on the product, is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.

For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide, part number 68-290-01, on the Extron website,

www.extron.com

.

Sicherheitsanweisungen • Deutsch

WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer darauf aufmerksam machen, dass im Inneren des Gehäuses dieses Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und die einen elektrischen Schlag verursachen können.

VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung (Instandhaltung) geben.

Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung, EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer 68-290-01) auf der Extron-Website,

www.extron.com

.

Instrucciones de seguridad • Español

ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto, avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del producto, lo que puede representar un riesgo de descarga eléctrica.

ATENCIÓN: al usuario de la presencia de importantes instrucciones de uso y mantenimiento recogidas en la documentación proporcionada con el equipo.

Este símbolo, , cuando se utiliza en el producto, avisa Para obtener información sobre directrices de seguridad, cumplimiento de normativas, compatibilidad electromagnética, accesibilidad y temas relacionados, consulte la Guía de cumplimiento de normativas y seguridad de Extron, referencia 68-290-01, en el sitio Web de Extron,

www.extron.com

.

Instructions de sécurité • Français

AVERTISSEMENT : un choc électrique.

Ce pictogramme, , lorsqu’il est utilisé sur le produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit d’une tension électrique dangereuse susceptible de provoquer ATTENTION : matériel.

Ce pictogramme, , lorsqu’il est utilisé sur le produit, signale à l’utilisateur des instructions d’utilisation ou de maintenance importantes qui se trouvent dans la documentation fournie avec le Pour en savoir plus sur les règles de sécurité, la conformité à la réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets connexes, lisez les informations de sécurité et de conformité Extron, réf. 68-290-01, sur le site Extron,

www.extron.com

.

Istruzioni di sicurezza • Italiano

AVVERTENZA: scosse elettriche.

Il simbolo, , se usato sul prodotto, serve ad avvertire l’utente della presenza di tensione non isolata pericolosa all’interno del contenitore del prodotto che può costituire un rischio di ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad avvertire l’utente della presenza di importanti istruzioni di funzionamento e manutenzione nella documentazione fornita con l’apparecchio.

Per informazioni su parametri di sicurezza, conformità alle normative, compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento alla Guida alla conformità normativa e di sicurezza di Extron, cod. articolo 68-290-01, sul sito web di Extron,

www.extron.com

.

Instrukcje bezpieczeństwa • Polska OSTRZEŻENIE :

Ten symbol, , gdy używany na produkt, ma na celu poinformować użytkownika o obecności izolowanego i niebezpiecznego napięcia wewnątrz obudowy produktu, który może stanowić zagrożenie porażenia prądem elektrycznym.

UWAGI:

Ten symbol, , gdy używany na produkt, jest przeznaczony do ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji (obsługi) w literaturze, wyposażone w sprzęt.

Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne, zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część numer 68-290-01, na stronie internetowej Extron,

www.extron.com

.

Инструкция по технике безопасности • Русский ПРЕДУПРЕЖДЕНИЕ:

на продукте, предупреждает пользователя о наличии неизолированного опасного напряжения внутри корпуса продукта, которое может привести к поражению электрическим током.

Данный символ, , если указан

ВНИМАНИЕ:

Данный символ, , если указан на продукте, предупреждает пользователя о наличии важных инструкций по эксплуатации и обслуживанию в руководстве, прилагаемом к данному оборудованию.

Для получения информации о правилах техники безопасности, соблюдении нормативных требований, электромагнитной совместимости (ЭМП/ЭДС), возможности доступа и других вопросах см. руководство по безопасности и соблюдению нормативных требований Extron на сайте Extron: ,

www.extron.com

, номер по каталогу - 68-290-01.

安全说明 • 简体中文 警告 : 产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压, 有触电危险。

注 意

: 产 品 上 的 这个 标 志 意 在 提 示 用 户 设 备 随 附 的 用 户 手 册 中 有 重要的操作和维护(维修)说明。 关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍 使用的特性等相关内容,敬请访问 Extron 网站 ,

www.extron.com

,参见 Extron 安全规范指南,产品编号 68-290-01 。

安全記事 • 繁體中文

警 告

: 若產品 上使 用此 符 號 ,是 為了提 醒 使 用者,產品 機 殼內 存 在 著 可能會導致觸電之風險的未絕緣危險電壓。 注意 若產品上使用此符號,是為了提醒使用者,設備隨附的用戶手冊中有 重要的操作和維護(維修)説明 。 有關安全性指導方針、法規遵守、EMI/EMF 相容性、存取範圍和相關主題的詳細資 訊,請瀏覽 Extron 網站:

www.extron.com

,然後參閱《Extron 安全性與法規 遵守手冊》,準則編號 68-290-01。 安全上のご注意

日本語

警告:

この記号 が製品上に表示されている場合は、筐体内に絶縁されて いない高電圧が流れ、感電の危険があることを示しています。

注意:

この記号 が製品上に表示されている場合は、本機の取扱説明書に 記載されている重要な操作と保守(整備)の指示についてユーザーの注意 を喚起するものです。 安全上のご注意、法規厳守、EMI/EMF適合性、その他の関連項目に ついては、エクストロンのウェブサイト

www.extron.com

より 『 Extron Safety and Regulatory Compliance Guide 』 ( P/N 68-290-01 ) をご覧ください。

안전 지침 • 한국어 경고:

이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는 접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을 경고합니다.

주의:

이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와 있는 주요 운영 및 유지보수(정비) 지침을 경고합 니다.

안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에 대한 자세한 내용은 Extron 웹 사이트(

www.extron.com

)의 Extron 안전 및 규제 준수 안내서, 68-290-01 조항을 참조하십시오.

Copyright

© 2009-201 9 Extron Electronics. All rights reserved.

www.extron.com

Trademarks

All trademarks mentioned in this guide are the properties of their respective owners.

The following registered trademarks ( ® ), registered service marks ( SM ), and trademarks ( TM ) are the property of RGB Systems, Inc. or Extron Electronics (see the current list of trademarks on the

Terms of Use

page at

www.extron.com

):

Registered Trademarks

(

®

) Extron, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Flat Field, FlexOS, Glitch Free. Global Configurator, Global Scripter, GlobalViewer, Hideaway, HyperLane, IP Intercom, IP Link, Key Minder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA, PlenumVault, PoleVault, PowerCage, PURE3, Quantum, Show Me, SoundField, SpeedMount, SpeedSwitch, StudioStation, System 

INTEGRATOR

, TeamWork, TouchLink, V-Lock, VideoLounge, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, XTP Systems, and ZipClip

Registered Service Mark (SM) :

S3 Service Support Solutions

Trademarks ( ™ )

AAP, AFL (Accu-Rate Frame Lock), ADSP (Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS (Class D Ripple Suppression), Codec Connect, DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), Driver Configurator, DSP Configurator, DSVP (Digital Sync Validation Processing), eLink, EQIP, Everlast, FastBite, FOX, FOXBOX, IP Intercom HelpDesk, MAAP, MicroDigital, Opti-Torque, PendantConnect, ProDSP, QS-FPC (QuickSwitch Front Panel Controller), Room Agent, Scope-Trigger, ShareLink, SIS, Simple Instruction Set, Skew-Free, SpeedNav, Triple-Action Switching, True4K, Vector™ 4K , WebShare, XTRA, and ZipCaddy

FCC Class B Notice

NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, you are encouraged to try to correct the interference by one or more of the following measures: • • Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

• • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of the manufacturer could void the user’s authority to operate this equipment.

NOTE: For more information on safety guidelines, regulatory compliances, EMI/ EMF compatibility, accessibility, and related topics see the “

Extron Safety and Regulatory Compliance Guide

” on the Extron website.

Conventions Used in this Guide

Notifications

The following notifications are used in this guide: WARNING: Potential risk of severe injury or death. AVERTISSEMENT : Risque potentiel de blessure grave ou de mort.

CAUTION: Risk of minor personal injury.

ATTENTION : Risque de blessure mineure.

ATTENTION:

Risk of property damage.

Risque de dommages matériels.

NOTE: A note draws attention to important information.

Specifications Availability

Product specifications are available on the Extron website,

www.extron.com

.

Extron Glossary of Terms

A glossary of terms is available at

http://www.extron.com/technology/glossary.aspx

.

Contents

Introduction

.................................................... 1 About this User Guide ........................................ 1 Terms Used in this User Guide ........................ 1

Features ............................................................. 2

Installation

...................................................... 3 Application Examples ......................................... 3

Installing the XPA Amplifier .................................. 6

Operation

........................................................ 9 Front Panel Features and Operation ................... 9

Rear Panel Features and Operation .................. 11

Bridged Mode Output ................................... 17

Troubleshooting ................................................ 20 Amplifier Fails to Exit Standby Mode Promptly ...................................................... 20

Amplifier Enters Standby Mode Too Early ..... 21 Limiter/Protect LED Warning Indicators......... 21 Over Temp Indicator LED .............................. 21

Reference Information

................................. 22 Mounting the XTRA Series of Power Amplifiers ........................................................ 22 Tabletop Use ................................................ 22 UL Rack Mounting Guidelines ....................... 22

Rack Mounting ............................................. 23

XTRA Full Rack Power Amplifier Series • Contents v

Introduction About this User Guide

This user guide contains information about the Extron series of full rack width audio power amplifiers. The Extron XTRA™ Series is a family of 1U convection cooled power amplifiers with mono, stereo, and multi-channel outputs. These professional grade amplifiers deliver from 200 to 800 watts of continuous output power and are available for low and high impedance applications. Each model offers professional grade signal-to-noise ratio and THD+N performance. XTRA Series amplifiers are ENERGY STAR® qualified amplifiers with an Extron exclusive, highly efficient, advanced Class D amplifier design. They also feature patented CDRS™ - Class D Ripple Suppression technology that provides a smooth, clean audio waveform and an improvement in signal fidelity over conventional Class D amplifiers. XTRA Series amplifiers are one quarter to one half the size of comparable amplifiers, conserving rack space. The Extron exclusive, high efficiency design generates very little heat and allows the amplifiers to be convection cooled.

The XPA series of amplifiers are full-rack width models with different power outputs: • The XPA 2002-70V two channel amplifier delivers 200 watts rms per channel for 70 volt high impedance speaker systems.

• • The XPA 2002-100V two channel amplifier delivers 200 watts rms per channel for 100 volt high impedance speaker systems.

The XPA 2003C-70V three channel amplifier delivers two channels of 200 watts rms into 4 ohms or 100 watts rms into 8 ohms. It delivers a third channel with 200 watts rms into a 70 volt line for high impedance speaker systems.

• • • • The XPA 2003C-100V three channel amplifier delivers two channels of 200 watts rms into 4 ohms or 100 watts rms into 8 ohms. It delivers a third channel with 200 watts rms into a 100 volt line for high impedance speaker systems.

The XPA 2004 four channel amplifier delivers 200 watts rms per channel into 4 ohms or 100 watts rms per channel into 8 ohms. It features a bridged mode that provides two channels of 400 watts rms output into 8 ohms.

The XPA 4002 two channel low impedance amplifier delivers 400 watts rms per channel into 4 ohms or 200 watts rms per channel into 8 ohms. It features a bridged mode that provides a single 800 watt output into 8 ohms.

The XPA 4002-70V two channel amplifier delivers 400 watts rms per channel for 70 volt high impedance speaker systems.

Terms Used in this User Guide

The terms “amplifier” and “power amplifier” are used interchangeably in this guide to refer to each model.

XTRA Full Rack Power Amplifier Series • Introduction 1

Features

Extron Patented Class D Ripple Steering (CDRS microphones.

™) technology — CDRS is an Extron patented technology that provides a smooth, clean audio waveform and an improvement in signal fidelity over conventional Class D amplifier designs. CDRS eliminates the high frequency switching ripple characteristic of Class D amplifiers, a source of RF emissions, which can interfere with sensitive A/V equipment such as wireless Professional grade signal-to-noise and THD performance — Delivers professional grade performance with 100 dB signal-to-noise ratio and THD of less than 0.1%.

Front and rear panel LED indicators — • Display limiter/protect status when audio limiting or amplifier malfunction occurs.

• Indicate the presence of input signals.

Audio level adjustment — Potentiometers to adjust the audio level from = (full attenuation) to 0 dB (no attenuation).

IEC power switch — Rear panel IEC rocker power switch.

1U full rack enclosure — The capability to deliver full-sized amplifier power in one half the size of many comparable power amplifiers.

High pass filtering — A high pass filter (XPA 2002-70V, XPA 2002-100V, XPA 4002-70V, XPA 2003C-70V, and XPA 2003C-100V only) toggle switch prevents saturation of speaker input transformers by low frequency signals. Saturation can result in severe distortion of the speaker output signal.

Bridged output mode — The XPA 2004 has a toggle switch to input channels 1 and 3 and output each input as a single bridged output channel at twice the power of a single channel. Input 1 is output over the positive terminals of output channels 1 and 2. Input 3 is output over the positive terminals of output channels 3 and 4.

The XPA 4002 has a toggle switch to input channel 1 and output a single bridged output channel at twice the power using the positive terminals of channels 1 and 2. Convection cooled, fanless operation — Ensuring quiet reliable operation. All models generate substantially less heat than similar power amplifer designs.

Automatic clip limiter — Detects actual onset of clipping by comparing input and output waveforms. Gain is automatically reduced with a slow attack and fast release to eliminate clipping. This advanced limiter design protects the speakers from clipping distortion and offers superior sonic characteristics compared to limiters that use signal compression. Rear panel recessed, detented attenuation controls — Provide attenuation of input signals for adjusting audio system gain staging as well as multi-zone applications. They are located on the rear panel to prevent users from tampering with level adjustments.

Remote standby — Standby control that remotely shuts off all amplifier output while power remains active at the amplifier. Power factor correction — Features power factor correction technology that smoothes out the high peak currents of the current draw of the amplifier, thus minimizing the presence of high frequency harmonics on the AC power line, and therefore preventing audible artifacts from being transmitted to other audio equipment in the system. Class 2 wiring — The outputs from the amplifiers support Class 2 wiring that meets UL requirements.

ENERGY STAR ® qualified — All models are ENERGY STAR qualified amplifiers that conserve energy and reduce costs.

XTRA Full Rack Power Amplifier Series • Introduction 2

Installation

This section discusses how to install the XTRA Series of full rack power amplifiers.

WARNING: Installation and service must be performed by authorized personnel only (see

UL Rack Mounting Guidelines

).

AVERTISSEMENT : L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement (voir

UL Rack Mounting Guidelines

).

Application Examples

The following application examples for the XPA 2002-70V, XPA 2002-100V, XPA 2003C-70V, XPA 2003C-100V, XPA 2004, XPA 4002, and XPA 4002-70V.

Extron XPA 2002-70V

or

XPA 2002-100V

Power Amplifier

-24 0V .5A

, 50 Hz -60 XP A 2 002 70V EEN BE - A R CT ST IVE DB REM OTE LIM PR ITE OTE R/ 12 10 14 26∞ ATT EN TION UA 12 10 14 26∞ SIG NA INPUT HP OF 70 V O UT PUT NG IRI CL AS S 2 W Extron SF 26CT

Two-Way Ceiling Speakers

Extron SF 26CT

Two-Way Ceiling Speakers

Equipment Room Rack

GREEN - ACTIVE AMBER - STANDBY OVER TEMP 1 2 LIMITER / PROTECT SIGNAL XPA 2002

INPUTS

1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8

OUTPUTS LOGO SELECT ENTER CONTROL PRESET VIEW ESC VIDEO I/O AUDIO CONFIG MIC VOLUME VOLUME DTP CROSSPOINT 4K SERIES DIGITAL PRESENTATION MATRIX Extron XPA 2002-70V

or

XPA 2002-100V

Power Amplifier Blu-ray Player

Extron DTP CrossPoint 86 4K

Scaling Presentation Matrix Switcher PC

Figure 1. XPA 2002-70V and XPA 2002-100V Application Example XTRA Full Rack Power Amplifier Series • Installation 3

Extron XPA 2003C-70V

or

XPA 2003C-100V

Combo Power Amplifier

Extron XPA 2003C-70V

or

XPA 2003C-100V

Combo Power Amplifier

Extron SM 28

Surface-Mount Speakers

-24 100 0V 1 , 50 -60 Hz XP A 2 003 C-7 0V GR EEN AM BE - A R CT RE MO TE LIM OT ITE R/ TE NU AT ION 12 10 14 12 10 14 18 26∞ 10 12 14 ∞ ∞ SIG NA INP UT HPF Hz 80 OF OU TPU TS 70 8Ω / 4 Ω CL AS S 2 W IRI NG Extron SF 26CT

Two-Way Ceiling Speakers Wireless Microphone Receiver Blu-ray Player

Extron DTP CrossPoint 86 4K

Scaling Presentation Matrix Switcher PC

GREEN- ACTIVE AMBER - STANDBY OVER TEMP LIMITER / PROTECT SIGNAL XPA 2003C INPUTS

1 2 3 4 5 6 7 8 9 10

LOGO SELECT

1 2 3 4 5 6 7 8

OUTPUTS ENTER CONTROL PRESET VIEW ESC VIDEO I/O AUDIO CONFIG MIC VOLUME VOLUME DTP CROSSPOINT 4K SERIES DIGITAL PRESENTATION MATRIX Figure 2. XPA 2003C-70V and XPA 2003C-100V Application Example Extron SSP 7.1

Surround Sound Processor GREEN - ACTIVE AMBER - STANDBY OVER TEMP LIMITER / PROTECT SIGNAL GREEN - ACTIVE AMBER - STANDBY OVER TEMP

CONFIG SOURCE DTS D PCM 2-CH MODE OVERRIDE DOWNMIX PL II/IIx DTS NEO:6 TO ALL INPUTS

LIMITER / PROTECT SIGNAL

CLIP VOLUME SSP 7.1

SURROUND SOUND PROCESSOR Extron XPA 2004

Four Channel Power Amplifiers XPA 2004 XPA 2004 DBS RECEIVER

Extron SM 28

Surface-mount Speaker Left Front

Extron SM 28

Surface-mount Speaker Center

Extron SM 28

Surface-mount Speaker Right Front

tron tron

Subwoofer

tron

DBS Receiver

INPUTS

1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8

OUTPUTS LOGO SELECT ENTER CONTROL PRESET VIEW ESC VIDEO I/O AUDIO CONFIG MIC VOLUME VOLUME DTP CROSSPOINT 4K SERIES DIGITAL PRESENTATION MATRIX Extron SM 26

Surface-mount Speaker Left Side PC

Extron DTP CrossPoint 86 4K

Scaling Presentation Matrix Switcher Blu-ray Player Laptop

Extron SM 26

Surface-mount Speaker Left Back

Extro Extron SM 26

Surface-mount Speaker Right Back

Extron SM 26

Surface-mount Speaker Right Back

Extron Figure 3. XPA 2004 Application Example XTRA Full Rack Power Amplifier Series • Installation 4

Extron XPA 2004

Power Amplifier

Extron XPA 4002

Power Amplifiers Two-way Bi-Amplified Speakers

100 -24 1 .5A, -60 Hz XP A 200 EEN AM - A IVE MO RE TE ITE PR ECT NA SIG 26∞ AT TE TIO (BR IDG E A INPUT IDG E B IDG BR DE ON OF 8Ω / 4 IDG E A UT Ω O PU IDG E B BRI W AS S 2 IRI 100 -24 1 .5A

, 50 -60 Hz A 4 002 EEN - A - S TAN AM BER IVE MO RE TE ITE PR EC AT NU AT INP UT (BR IDG BR IDG E M OD ON OF / 4 Ω O BR PU TS IDG S 2 CL AS IRI NG INP UT (BR IDG BR IDG E M OD ON OF / 4 Ω O PU UT TS IDG IRI NG CL AS W 100 -24 , 50 1 .5A

-60 Hz A 4 XP 002 AM BER - S TAN EEN - A IVE MO TE ITE OT PR EC NA SIG AT NU ION AT

Bi-Amplified System: High Frequency Low Frequency Two-way Bi-Amplified Speakers

Extron XPA 2004

Power Amplifier

Extron XPA 4002

Power Amplifiers

Extron DMP 128 Plus AT

Digital Matrix Processor

Equipment Room Rack

GREEN - ACTIVE AMBER - STANDBY OVER TEMP GREEN - ACTIVE AMBER - STANDBY OVER TEMP LIMITER / PROTECT SIGNAL LIMITER / PROTECT SIGNAL GREEN - ACTIVE AMBER - STANDBY OVER TEMP LIMITER / PROTECT SIGNAL XPA 2004 XPA 4002 XPA 4002

100-240V 0.7A MAX 50 - 60 Hz 10 IN O1 O2 CLIP SIGNAL IN EXP INPUTS O1O2 IN O1 O2 IN ACTIVITY LAN USB O1 O2 IN O1 O2 OUTPUTS O1 O2 CLIP SIGNAL IN CLIP IN SIGNAL O1O2 IN 11 12 10 DMP 64 DIGITAL MATRIX PROCESSOR 11 12 CLIP SIGNAL OUTPUTS DMP 128 Plus AT +V +S -S G RS-232 Tx Rx (SEC) LAN (PRI) USB AUDIO RESET DMP 128 Plus DIGITAL MATRIX PROCESSOR Figure 4. XPA 4002 Application Example 100 -24 1 0V , 50 -60 Hz XP A 4 002 -70 GR EEN IVE AN DB TE RE MO LIM ITE PR OTE R/ CT SIG NA ATT EN INPU TS HP 80 Hz OF CL AS WI S 2 UT V O 70 UTP RIN Extron XPA 4002-70V

Power Amplifiers

100 -24 1 0V , 50 -60 Hz XP A 4 002 -7 0V GR AM EEN IVE AN DB RE TE LIM ITE R/ PR OTE CT SIG NA ATTE NU AT ION INPU TS HP 80 Hz OF V O CL AS WI S 2 UT RIN Equipment Room Rack

OVER TEMP 1 2 LIMITER / PROTECT SIGNAL GREEN - ACTIVE AMBER - STANDBY OVER TEMP 1 2 LIMITER / PROTECT SIGNAL XPA 4002 XPA 4002 Paging Floor 4 Paging Floor 3 Paging Floor 2 Paging Floor 1

Extron XPA 4002-70V

Power Amplifiers Paging System

Extron SF 3CT LP

Full-Range Ceiling Speakers

Figure 5. XPA 4002-70V Application Example XTRA Full Rack Power Amplifier Series • Installation 5

Installing the XPA Amplifier

1. 2.

Power off — Turn off all equipment including the XPA amplifier by toggling the power switch off and disconnecting the power cord. Verify that the amplifier is disconnected from the power source before proceeding.

Mount the amplifier — For diagrams of typical application examples, see the

Application Examples

section. For further mounting instructions, see the

Mounting the XTRA Series of Power Amplifiers

section.

3.

Wire the source(s) — Wire the input to the 3.5 mm input connectors of the amplifier,

as shown in the following illustration (see the

Rear Panel Features and Operation

section for bridging information). NOTE: Control signal ground pins may be labeled as or G. Audio ground pins may be labeled as or . The wiring and function are the same, whichever way your product is labeled.

" (5 mm) MAX.

Tip Sleeve

Unbalanced Input

Tip Ring Sleeve

Balanced Input 1 (BRIDGE) 2 Figure 6. Wiring 3-pole Connectors

NOTE: The wires must not be tinned: tinned wire does not hold tight in the captive screws and can break easily after several bends.

4.

Wire the outputs connector. — Wire speakers to the output connectors of the amplifier using the included 2-pole (70 V or 100 V) or 4-pole (8 ohm or 4 ohm) captive screw 2-pole (70 V or 100 V) output connector wiring:

Do not tin the wires!

1 Figure 7. Wiring 2-pole Connectors

ATTENTION:

Do not short out the + and - connectors with each other or to ground. Doing so will short the outputs and may damage the amplifier.

Ne créez pas de court-circuit entre les connecteurs «+» et «-» ou entre eux et la mise à la terre : cela pourrait créer un court-circuit aux sorties et endommager l’amplificateur.

XTRA Full Rack Power Amplifier Series • Installation 6

4-pole (8 ohm or 4 ohm) output connector wiring:

Do not tin the wires!

1 OUTPUT 2 1 2 Figure 8. Wiring 4-pole Connectors

ATTENTION:

Do not short the + and outputs to each other. Doing so may damage the amplifier.

Ne pas créer un court circuit entre les sorties + et au risque d’endommager l’amplificateur.

5.

For complete wiring details, see the

Rear Panel Features and Operation

section.

Bridge outputs (XPA 2004, and XPA 4002)

(see the

Bridged Mode Output

— Bridging the output of input 1 (XPA 4002) or inputs 1 and 3 (XPA 2004) doubles the output of each respective input

section for further details). The bridge output mode

toggle switch is shown at right. ON Bridge mode — XPA 4002 Bridging takes the signal from input 1 and outputs the combined output of 800 watts from the + terminals of output channels 1 and 2 (see the diagram at right). Toggle the bridged output mode switch up (bridged) or down (unbridged). Bridge mode — XPA 2004 Bridging takes the signal from input 1, input 3 or both and outputs the combined output of 400 watts from the + terminals of output channels 1 and 2 (Bridge A), or output channels 3 and 4 (Bridge B), or both (see the diagram at right). Toggle the bridged output mode switch up (bridged) or down (unbridged) for the appropriate input channel.

8Ω / 4Ω OUTPUTS 8 Ohm 1 BRIDGE 2

OFF

BRIDGE 8Ω ONLY CLASS 2 WIRING

NOTE: When you are bridging outputs, the minimum load impedance is 8 ohms.

NOTE: Adjust the attenuation level to = before powering the amplifier back up

in step 8 (see the

Rear Panel Features and Operation

section for further details). On some models, this adjustment is referred to as “level,” but the function is the same, whichever way your product is labeled.

XTRA Full Rack Power Amplifier Series • Installation 7

6. 7. 8. 9.

Set the high pass filter — Use a small screwdriver to toggle this switch between off (no filtering) and 80 Hz (default).

• • • The XPA 2002-70V, XPA 2002-100V, and XPA 4002-70V have two switches, one for each output channel.

1 HPF 2 HPF 3

The XPA 2003C-70V and the XPA 2003C-100V have one switch for the 70 V (XPA 2003C-70V) or 100 V (XPA 2003C-100V) line distribution output channel (channel 3). Setting the switch to 80 Hz prevents the saturation of speaker input transformers output signal.

80 Hz OFF

XPA 2002-70V XPA 2002-100V XPA 4002-70V

80 Hz OFF

XPA 2003C-70V XPA 2003C-100V

by low frequency signals. Saturation can result in severe distortion of the speaker If desired, wire a contact closure device to the remote standby connector. Connecting pin 2 to ground (pin 1) places the amplifier in standby mode. Standby mode turns off all outputs, although the amplifier is still receiving power. To Contact Closure Port on Control Device Use the included 2-pin, 3.5 mm captive screw connector to jumper the pins.

G STANDBY

Turn on the amplifier — Reconnect all power cords and switch on all other equipment before powering up the power amplifier. ATTENTION:

The amplifier must be powered up last. The front panel LED of the amplifier should light green.

L’amplificateur doit être allumé en dernier. Le LED situé sur le panneau de l’amplificateur devrait s’allumer en vert.

Adjust the attenuation level using the rear panel adjustment potentiometers (shown below). To adjust the input level of the XPA amplifier, do the following:

a.

If connecting to a source device with a volume control (variable output), ensure that the volume on the source device is 14 18 26 12 1 10 8 0 6 2 14 12 4 2 10 LEVEL 8 0 6 2 4 14 12 3 10 8 0 6 2 4 14 12 4 10 set to its lowest point, then adjust the level of the XPA fully counterclockwise.

8 0 6 2 4

b.

Set the source device’s volume to its maximum volume level. No sound should come out.

c.

Return to the XPA amplifier and raise the level until sound distortion occurs, then lower the level slightly until any distortion disappears. This setting ensures that, whatever the source device volume setting may be, no clipping occurs. NOTE: When setting volume control through a source device, ensure that the volume of the device is set to variable out. Consult the user manual of the device for detailed instructions on its calibration.

XTRA Full Rack Power Amplifier Series • Installation 8

Operation

This section discusses how to operate the XPA power amplifiers. Topics that are covered, include: •

Front Panel Features and Operation

• •

Rear Panel Features and Operation

Bridged Mode Output

Troubleshooting

Front Panel Features and Operation

The XPA power amplifier front panels are shown below.

D

GREEN - ACTIVE AMBER - STANDBY OVER TEMP 1 2 LIMITER / PROTECT SIGNAL XPA 2002-70V, Front Panel

A B C

and XPA 2002-100V

D

XPA 2002 GREEN - ACTIVE AMBER - STANDBY OVER TEMP 1 2 3 LIMITER / PROTECT SIGNAL XPA 2003C-70V Front Panel

A B

and XPA 2003C-100V

C D

XPA 2004 Front Panel GREEN - ACTIVE AMBER - STANDBY OVER TEMP 1 2 3 4 LIMITER / PROTECT SIGNAL

A B C

XPA 2003C XPA 2004 XTRA Full Rack Power Amplifier Series • Operation 9

D

GREEN - ACTIVE AMBER - STANDBY OVER TEMP 1 2 LIMITER / PROTECT SIGNAL XPA 4002 XPA 4002 and XPA 4002-70V Front Panel

A B C

Figure 9. XPA Power Amplifier Front Panels

A Power indicator LED B Over temp indicator LED C D Signal indicator LEDs Limiter/Protect indicator LEDs A Power indicator LED — This LED lights: • Green when the amplifier is receiving full power. • Amber when the amplifier is in Standby mode. Standby mode turns off all

outputs from the amplifier, although the amplifier is still receiving power (see

C

of

Rear Panel Features and Operation

)

.

B Over Temp indicator LED — This LED lights red when the amplifier exceeds the recommended operating temperature for optimal lifetime. The LED turns off after the amplifier has cooled down sufficiently. Should the LED light, check the following: • Verify that the placement of the amplifier allows for adequate ventilation and airflow. • Avoid placing other equipment on top of the amplifier.

• Verify that the operating temperature is within the specified range.

C Signal indicator LEDs (channels 1, 2, 3, and 4) corresponding channel.

— These LEDs (representing input channels 1, 2, 3, and 4) light green only when an input signal is detected on the NOTE: These LEDs are also located on the rear panel.

D Limiter/Protect indicator LEDs (channels 1, 2, 3, and 4) — These LEDs (representing output channels 1, 2, 3, and 4) light red in the following circumstances: • When audio clipping occurs, the corresponding LED turns on while the amplifier is limiting. • When the amplifier overheats, both Over Temp and Limiter/Protect indicator LEDs are lit. The LEDs are not lit after the amplifier recovers from the overheated condition.

XPA 4002 • When the output leads are shorted, the LED of the corresponding channel is lit until the short is removed.

NOTE: These LEDs are also located on the rear panel.

XTRA Full Rack Power Amplifier Series • Operation 10

Rear Panel Features and Operation

The XPA power amplifier rear panels are shown below.

XPA 2002-70V Rear Panel XPA 2002-70V Rear Panel XPA 2003C-70V Rear Panel XPA 2003C-100V Rear Panel XPA 2004 Rear Panel XPA 4002 Rear Panel 100-240V 1.5A, 50-60 Hz

A B E

XPA 2002-70V GREEN - ACTIVE AMBER - STANDBY REMOTE G LIMITER/ PROTECT 1 2 ATTENUATION 1 12 10 14 18 26 ∞ 8 6 4 0 2 14 18 26 ∞ 2 12 10 8 6 4 0 2 SIGNAL

C D F G

100-240V 1.5A, 50-60 Hz

A B

100-240V 1.5A, 50-60 Hz

A B E

XPA 2002-70V GREEN - ACTIVE AMBER - STANDBY REMOTE G LIMITER/ PROTECT 1 2 ATTENUATION 1 12 10 14 18 26 ∞ 8 6 4 0 2 14 18 26 ∞ 2 12 10 8 6 4 0 2 SIGNAL

C D F C D F G E

XPA 2003C-70V GREEN - ACTIVE AMBER - STANDBY REMOTE G LIMITER/ PROTECT 1 2 3 ATTENUATION 1 14 18 12 10 8 26 ∞ 0 2 6 12 14 10 4 2 ∞ 8 4 0 2 3 12 10 ∞ 8 6 4 0 2 SIGNAL

G

1 INPUTS 2

H

1 INPUTS 2

H

1 INPUTS 2 3

H

1 HPF 2 80 Hz OFF

I

1 HPF 2 80 Hz OFF

I

1 70 V OUTPUTS CLASS 2 WIRING 2

J

1 70 V OUTPUTS CLASS 2 WIRING 2

J

HPF 3 80 Hz OFF 1 8Ω / 4Ω 2 OUTPUTS 70 V 3 CLASS 2 WIRING

I K J

100-240V 1.5A, 50-60 Hz

A B

100-240V 1.5A, 50-60 Hz

A B

100-240V 1.5A, 50-60 Hz

A B

XPA 2003C-100V

C E

REMOTE G LIMITER/ PROTECT 1 2 3 ATTENUATION 14 18 12 10 26 ∞ 1 8 6 12 14 10 4 0 2 ∞ 2 8 6 12 4 0 2 ∞ 3 10 8 6 4 0 2 SIGNAL

D F G

XPA 2004 GREEN - ACTIVE AMBER - STANDBY

E

REMOTE G ATTENUATION LIMITER/ PROTECT 1 2 3 4 1 2 3 4 18 26 ∞ 10 8 6 14 4 0 2 12 10 ∞ 8 6 0 2 4 12 10 ∞ 8 6 14 4 0 2 12 10 ∞ 8 6 4 0 2 SIGNAL 1 (BRIDGE A) 2 INPUTS 3 (BRIDGE B) 4 BRIDGE MODE A B ON OFF 8Ω / 4Ω OUTPUTS BRIDGE A BRIDGE B 1 2 3 4 CLASS 2 WIRING

H L K C D F E G

XPA 4002 GREEN - ACTIVE AMBER - STANDBY REMOTE G LIMITER/ PROTECT 1 2 ATTENUATION 1 2 14 12 10 18 26 8 0 6 14 12 2 4 10 8 0 6 2 4 SIGNAL INPUTS 1 (BRIDGE) 2 BRIDGE MODE 8Ω / 4Ω OUTPUTS BRIDGE 1 2 ON OFF CLASS 2 WIRING

C D F G

1 INPUTS 2 3

H H

HPF 3 80 Hz OFF 1 8Ω / 4Ω 2 OUTPUTS 100 V 3 CLASS 2 WIRING

I K J L K

XTRA Full Rack Power Amplifier Series • Operation 11

E

100-240V 1.5A, 50-60 Hz XPA 4002 -70V REMOTE G LIMITER/ PROTECT 1 2 1 14 12 10 18 26 8 6 2 4 0 ATTENUATION 2 14 12 10 8 18 26 0 6 2 4 SIGNAL 1 INPUTS 2 XPA 4002-70V Rear Panel

A B C D F G H

Figure 10. XPA Power Amplifier Rear Panels 1 HPF 2 80 Hz OFF 1 70 V OUTPUTS CLASS 2 WIRING 2

I J A B F

AC power connector Power switch

C

Power indicator LED

D

Remote standby connector

E

Limiter/Protect indicator LEDs Signal indicator LEDs

G

Attenuation adjustment

H

Balanced or unbalanced stereo/mono audio input connector

I

High pass filter toggle switch

J

Mono audio output connector

K

Stereo audio output connector

L

Bridged output mode

A AC power connector — Connect a standard IEC AC power cord here for power input (100 VAC to 240 VAC, 50/60 Hz) to the internal, autoswitching power supply.

B Power switch — This rocker switch turns power to the amplifier on or off.

C Power indicator LED — This LED lights: • Green when the amplifier is receiving full power. • Amber when the amplifier is in standby mode. Standby mode turns off all outputs from the amplifier, although the amplifier is still receiving power.

D Remote standby connector amplifier in standby mode. Use the included 2-pin, 3.5 mm captive — Connecting pin 2 to ground (pin 1) places the screw connector to jumper the pins.

To Contact Closure Port on Control Device

G STANDBY

NOTE: Control signal ground pins may be labeled as or G. Audio ground pins may be labeled as or . The wiring and function are the same, whichever way your product is labeled.

E Limiter/Protect indicator LEDs (channels 1, 2, 3, and 4) — These LEDs (representing output channels 1, 2, 3, and 4) light red in the following circumstances: • When audio clipping occurs, the corresponding LED turns on while the amplifier is limiting. • When the amplifier overheats, both over temp and limiter/protect indicator LEDs are lit. The LEDs are not lit after the amplifier recovers from the overheated condition.

• When the output leads are shorted, the LED of the corresponding channel is lit until the short is removed. F Signal indicator LEDs (channels 1, 2, 3 and 4) corresponding channel.

— These LEDs (representing input channels 1, 2, 3 and 4) light green only when an input signal is detected on the

XTRA Full Rack Power Amplifier Series • Operation 12

G

Attenuation adjustment (channels 1, 2, 3 and 4) — Use an Extron Tweeker or small screwdriver to adjust the audio input level for the corresponding channel. The analog potentiometers control the level from = (full attenuation) to 0 dB (no attenuation). 14 18 26 12 1 10 8 6 14 12 2 4 2 10 8 6 2 4 14 12 3 10 8 6 2 4 14 12 4 10 8 6 2 4 0 0 0 0

H

Balanced or unbalanced stereo/mono audio input connector — Wire the 3.5 mm 3-pin captive screw connectors for balanced or unbalanced input.

Tip Sleeve

Unbalanced Input " (5 mm) MAX.

Tip Ring Sleeve

Balanced Input

Left or Right

Figure 11. Wiring 3-pole Connectors

ATTENTION:

Do not tin the wire leads before installing into the connector. Tinned wires are not as secure in the connector and could be pulled out. They may also break after being bent several times.

Ne pas étamer les conducteurs avant de les insérer dans le connecteur. Les câbles étamés ne sont pas aussi bien fixés dans le connecteur et pourraient être tirés. Ils peuvent aussi se casser après avoir été pliés plusieurs fois.

NOTE: The XPA 2004 allows for bridged output of inputs 1 (Bridge A) and 3 (Bridge B) only. Bridging effectively doubles the output power of those inputs. Inputs 1 and 3 are the active inputs when in bridged mode while inputs 2 and 4 are ignored.

1 (BRIDGE A) 2 3 (BRIDGE B) 4

NOTE: The XPA 4002 allows for bridged output of input 1. Bridging effectively doubles the output power of input 1 while input 2 is ignored.

1 (BRIDGE) 2 XTRA Full Rack Power Amplifier Series • Operation 13

I

High pass filter toggle switch — Use a small screwdriver to toggle this recessed two-position toggle switch that alternates between Off (no filtering) and 80 Hz. The XPA 2002-70V, XPA 2002-100V, and XPA 4002-70V have two switches, one for each output channel. The XPA 2003C-70V and XPA 2003C-100V have one switch for the line distribution output channel (channel 3). Setting the switch to 80 Hz prevents the saturation of the speaker input transformers by low frequency signals. Saturation can result in severe distortion of the speaker output signal.

1 HPF

80 Hz OFF

2 XPA 2002-70V XPA 2002-100V XPA 4002-70V HPF

80 Hz OFF

3 XPA 2003C-70V XPA 2003C-100V

NOTE: It is recommended that the high pass filter be left in the On position unless filtering is applied to the signal upstream of the amplifier.

J

Mono audio output connector (see steps 1 4002-70V). and 2 — Wire the included 2-pole, 5 mm screw lock captive screw connector, marked “+” and “-,” for mono audio on the following page). Output is designed to power 70 V (XPA 2002-70V, XPA 4002-70V and XPA 2003C-70V) or 100 V (XPA 2002-100V and XPA 2003C-100V) line distribution systems and is rated at 200 watts (400 watts, XPA ATTENTION:

You must use Class 2 wiring for this output to comply with UL requirements.

Vous devez utiliser un câblage de classe 2 pour cette sortie afin de respecter les exigences de l’UL.

NOTE: You must use Class 2 wiring for this output to comply with UL requirements.

70 V OUTPUTS CLASS 2 WIRING 1 2 OUTPUTS 70 V 3 CLASS 2 WIRING XPA 2003C-70V XPA 2002-70V XPA 4002-70V 1 100 V OUTPUTS CLASS 2 WIRING 2 OUTPUTS 100 V 3 XPA 2002-100V Figure 12. Mono Audio Output Connectors CLASS 2 WIRING XPA 2003C-100V XTRA Full Rack Power Amplifier Series • Operation 14

ATTENTION:

Do not short out the + and - connectors with each other or to ground; doing so will short the outputs and may damage the amplifier.

Ne créez pas de court-circuit entre les connecteurs «+» et «-» ou entre eux et la mise à la terre : cela pourrait créer un court-circuit aux sorties et endommager l’amplificateur.

Step 1:

Strip and insert the speaker wires into the connector and tighten the captive screws. Be sure to observe correct polarity.

Do not tin the wires!

Step 2:

Insert the wired connector into the amplifier output and secure the locking screws on either side.

K

Stereo audio output connector each channel. See steps channel.

1 and 2 — Wire the included 4-pole, 5 mm screw lock captive screw connector to output 2-channel (XPA 4002, XPA 2003C-70V, and XPA 2003C-100V) or 4-channel (XPA 2004) audio. Observe the correct polarities for on the following page. Output is designed to power 4 or 8 ohm speakers and is rated at 200 watts (400 watts, XPA 4002) with a 4-ohm speaker load, or 100 watts (200 watts, XPA 4002) with an 8-ohm speaker load, per NOTE: You must use Class 2 wiring for this output to comply with UL requirements.

8Ω / 4Ω OUTPUTS BRIDGE 1 2 BRIDGE 8Ω ONLY 8Ω / 4Ω 1 2 OUTPUTS 8Ω / 4Ω OUTPUTS BRIDGE A BRIDGE 8Ω ONLY BRIDGE B 1 2 3 4 CLASS 2 WIRING XPA 4002 CLASS 2 WIRING XPA 2003C-70V XPA 2003C-100V Figure 13. Stereo Audio Output Connectors CLASS 2 WIRING XPA 2004 XTRA Full Rack Power Amplifier Series • Operation 15

ATTENTION:

Do not short the + and outputs to each other. Doing so may damage the amplifier.

Ne pas créer un court circuit entre les sorties + et au risque d’endommager l’amplificateur.

Step 1:

Strip and insert the speaker wires into the connector and tighten the captive screws. Be sure to observe the correct polarity.

Do not tin the wires!

Step 2:

Insert the wired connector into the amplifier output and secure the locking screws on either side.

1 OUTPUT 2

L

Bridged output mode (XPA 4002 and XPA 2004) channel 1 and bridging the outputs. — The output power of the XPA 4002 can be effectively doubled by using input The output power of the XPA 2004 can be effectively doubled by using input channels 1 or 3 or both and bridging their respective outputs.

• XPA 4002: Bridged output mode toggle switch (input channel 1) — Use a small screwdriver to toggle the recessed two-position toggle switch to either bridged (up) or unbridged (down) for input channel 1. Bridging takes the signal from Input 1 and outputs the signal from the + terminals of output channels 1 and 2.

BRIDGE MODE ON OFF

• XPA 2004: Bridged output mode toggle switch (input channels 1 and 3) — Use a small screwdriver to toggle the recessed two-position toggle switch to either bridged (up) or unbridged (down) for the appropriate input channels. Bridging takes the signal from Input 1 (A) or Input 3 (B) or both and outputs the signal from the + terminals of output channels 1 and 2 (Bridge A) or channels 3 and 4 (Bridge B) or both.

BRIDGE MODE A ON OFF B XTRA Full Rack Power Amplifier Series • Operation 16

Bridged Mode Output

XPA 4002 bridged mono output speaker wiring In bridged mode, the output mode toggle switch for Input 1 must be set to the bridged (up) position (see figure 8 below). For Input 1: The channel 1 + output terminal becomes the bridged + output terminal and the channel 2 + output terminal becomes the bridged “-” output terminal (see figure below).

BRIDGE MODE 8Ω / 4Ω OUTPUTS BRIDGE BRIDGE 8Ω ONLY 1 2 ON OFF CLASS 2 WIRING 8 Ohm Figure 14. XPA 4002 Bridged Mono Output Wiring

On the input end, only Input 1 is used in bridged mode.

INPUTS 1 (BRIDGE) 2

XPA 4002 bridged mono output using parallel speaker wiring In bridged mode, the output mode toggle switch for input 1 must be set to the bridged (up) position (see figure 7 below). The channel 1 + output terminal becomes the bridged + output terminal and the channel 2 + output terminal becomes the bridged - output terminal (see figure 15 below).

Mono + BRIDGE MODE 8Ω / 4Ω OUTPUTS BRIDGE BRIDGE 8Ω ONLY 1 2 8 Ohm Total Load 16 ohms 16 ohms ON OFF CLASS 2 WIRING Mono –

Two 16-ohm speakers wired in parallel equal an 8-ohm load.

Figure 15. XPA 4002 Bridged Mono Output Parallel Wiring XTRA Full Rack Power Amplifier Series • Operation 17

On the input end, only Input 1 is used in bridged mode.

INPUTS 1 (BRIDGE) 2

XPA 2004 bridged mono output speaker wiring In bridged mode, the output mode toggle switches for Input 1 (A) or Input 3 (B) or both must be set to the bridged (up) position (see figure 8 below). For Input 1: The channel 1 + output terminal becomes the bridged + output terminal and the channel 2 + output terminal becomes the bridged - output terminal (see figure 16 below). For Input 3: The channel 3 + output terminal becomes the bridged + output terminal and the channel 4 + output terminal becomes the bridged - output terminal (see figure 16 below).

Mono + Mono + BRIDGE MODE A B 8Ω / 4Ω OUTPUTS BRIDGE A BRIDGE 8Ω ONLY BRIDGE B 1 2 3 4 8 Ohm Load ON OFF 8 Ohm Load CLASS 2 WIRING Mono – Figure 16. XPA 2004 Bridged Mono Output Wiring

On the input end, only Input 1 or Input 3 or both Input 1 and Input 3 are used in bridged mode.

Mono – 1 (BRIDGE A) 2 INPUTS 3 (BRIDGE B) 4 XTRA Full Rack Power Amplifier Series • Operation 18

8 Ohm Total Load 16 ohms

XPA 2004 bridged mono output using parallel speaker wiring In bridged mode, the output mode toggle switches for Input 1 (A) or Input 3 (B) or both must be set to the bridged (Up) position (see figure 17 below). For Input 1: The channel 1 + output terminal becomes the bridged + output terminal and the channel 2 + output terminal becomes the bridged - output terminal (see figure 17 below). For Input 3: The channel 3 + output terminal becomes the bridged + output terminal and the channel 4 + output terminal becomes the bridged - output terminal (see figure 17 below).

Mono + 16 ohms Mono + BRIDGE MODE A B ON OFF 8Ω / 4Ω OUTPUTS BRIDGE A BRIDGE 8Ω ONLY BRIDGE B 1 2 3 4 CLASS 2 WIRING 16 ohms 16 ohms 8 Ohm Total Load Mono – Mono

Two 16 ohm speakers wired in parallel equal an 8 ohm load.

– Figure 17. XPA 2004 Bridged Mono Output Parallel Wiring

On the input end, only Input 1 or Input 3 or both Input 1 and Input 3 are used in bridged mode.

1 (BRIDGE A) 2 INPUTS 3 (BRIDGE B) 4 XTRA Full Rack Power Amplifier Series • Operation 19

Troubleshooting

The front and rear panels have LED warning indicators, as described in the following diagnostic information.

Amplifier Fails to Exit Standby Mode Promptly

The input channel (channels 1, 2, 3, and 4) Signal LED lights green per indicated input channel when an input signal is detected.

Power LED Color

Amber Green or Amber Amber Amber

Signal LED State

Not lit Lit intermittently Lit Lit

Problem Description

No output signal Slow to promptly exit standby mode with signal present.

No output signal DC fault is detected on either channel. Unit does not exit standby.

Problem Solution

No was input detected. Verify the input signal. If input is present, raise the input level until the signal LED lights.

The output signal level of the source may be too low to cross the signal detection threshold of the amplifier (see amplifier specifications for details). Increase the signal level of the source until the signal LED lights consistently.

The amplifier has been placed in standby mode and output has been turned off. Check the remoteport. A DC fault may have been detected (see below).

Disconnect power, then disconnect the remote port (if connected). Next, reconnect power to the unit to determine if the unit continues to go into immediate standby upon power up. In such a case, the unit should be serviced.

XTRA Full Rack Power Amplifier Series • Operation 20

Amplifier Enters Standby Mode Too Early

The input channel (channels 1, 2, 3, and 4) Signal LED lights green per indicated input channel when an input signal is detected.

Power LED Color

Green or Amber

Signal LED State

Lit intermittently

Problem Description

Enters standby mode early.

Problem Solution

The output signal level of the source may be too low to cross the signal detection threshold of the amplifier (see the amplifier specifications for details). Increase the signal level of the source until the signal LED lights consistently.

Limiter/Protect LED Warning Indicators

The output channel ( channels 1, 2, 3, and 4) Limiter/Protect LED lights red per indicated output channel as shown in the following diagnostic information.

LED State

Blinks Lights steady

Problem Description Problem Solution

Audio clipping is occurring and the Limiter/Protect LED is blinking.

Reduce the power output to avoid overdriving the amplifier and causing clipping.

The amplifier may be overheating. Determine the reason for the overheated state and allow the amplifier to cool. The LED is not lit after the amplifier recovers from the overheated state.

Output channel leads are shorted.

Check the speakers and speaker wiring for shorts.

Over Temp Indicator LED

This indicator does not represent a hard failure of the unit. It is meant as a warning that the amplifier has exceeded the recommended operating temperature for optional lifetime.

LED State Problem Description Problem Solution

Lights steady Amplifier has exceeded the recommended operating temperature. The LED turns off after the amplifier cools down sufficiently.

• • • Verify that the placement of the amplifier allows for adequate ventilation and airflow.

Avoid placing equipment on top of the amplifier.

Verify that the operating temperature is within the specified range.

XTRA Full Rack Power Amplifier Series • Operation 21

Reference Information

This section discusses the mounting instructions for the XPA seires of power amplifiers.

Mounting the XTRA Series of Power Amplifiers

The XPA power amplifiers can be set on a table or mounted on a rack shelf.

Tabletop Use

Four self-adhesive rubber feet are included with the audio amplifier. For tabletop use, attach one foot at each corner of the bottom side of the unit and place the unit in the desired location.

UL Rack Mounting Guidelines

The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the equipment in a rack.

1.

Elevated operating ambient temperature — If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the equipment in an environment compatible with the maximum ambient temperature (Tma = +122 °F/+50 °C) specified by Extron.

2. 3.

Reduced air flow — Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised. Mechanical loading — Mount the equipment in the rack so that a hazardous condition is not achieved due to uneven mechanical loading.

4. 5.

Circuit overloading — Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (for example, use of power strips).

XTRA Full Rack Power Amplifier Series • Reference Information 22

Rack Mounting

The XTRA series of audio amplifiers are housed in rack-mountable metal enclosures with pre-attached mounting ears for standard 19-inch racks. Mount the amplifier as follows:

1.

Disconnect all cables and power sources from the amplifier.

2.

Position the amplifier in the mounting rack so that the four slots in the mounting ears are aligned with the rack mounting holes. Use the included mounting screws to fasten the amplifier to the rack (see figure 18 below). ATTENTION:

Never place a load exceeding 40 pounds in weight on top of the rack mounted amplifier.

Ne placez jamais une charge de plus de 18 kg sur le dessus de l’amplificateur monté en rack.

Mounting Screws

100 240V 1 .5A, 50-60 Hz XP A 2004 IVE Y AMBER - S TANDB REMOTE G LIMITER/ 3 1 4 14 18 26 AT ION ATTENU 12 10 1 8 6 14 4 0 2 12 10 ∞ ∞ 2 8 6 0 14 4 2 12 ∞ 3 10 8 14 4 0 2 12 ∞ 4 10 8 6 0 2 1 (BRIDGE A) SIGNA L 2 INPUTS 3 (BRID GE B) 4 A ON OF B S B A 8Ω / 4 Ω OUTPUT ON LY BRIDGE 3 4 BRIDGE 1 2 CLASS 2 WIRING

Mounting Ear uses 5 screws (ea side).

Figure 18. Rack Mounting the Amplifier XTRA Full Rack Power Amplifier Series • Reference Information 23

Rack Mounting Ventilation Excessive heat can decrease the optimal lifetime of the power amplifier. An

operating temperature has been exceeded (see

over temp indicator LED on the front panel of the amplifier lights red whenever the recommended

Front Panel Features and Operation

).

To reduce the chances for an over temp condition, the XPA should be arranged in a rack environment with up to a maximum of four XPAs stacked together with a minimum of one vent space provided both above and below a stack (see figure 19 below).

100-240V 1.5A

, 50-60 Hz 240V 1.5A, 100 50-60 H z 100-240V 1.5A

, 50-60 Hz V 1.5A, 50 100-240 -60 H z 100-2 40V 1.5A, 50-60 H z 100-240V 1.5A

, 50-60 Hz 100-240V 1.5

A, 50-60 Hz V 1.5A, 50 100-240 -60 Hz ANDB Y GREEN - ACTIVE AMBER - ST ANDB Y GREEN - ACTIVE AMBER - ST ANDB Y GREEN - ACTIVE AMBER - ST ANDB GREEN - ACTIVE Y ANDB Y ANDB Y GREEN - ACTIVE AMBER - ST ANDB Y GREEN - ACTIVE AMBER - ST ANDB Y GREEN - ACTIVE AMBER - ST Ve nt 1 Sp TION ATTENUA 12 10 ∞ 2 8 6 0 2 12 10 3 8 6 ∞ 0 14 4 2 12 ∞ 10 4 8 6 4 0 2 1 (BRIDGE A) ac 2 2 INPUTS 3 (BRIDGE B) (BRIDGE B) e 4 4 E REMOT LIM ITE R/ T PROTEC 1 2 3 4 18 14 12 26 ∞ 10 8 14 0 2 INPUTS 3 1 G REMOTE SIGNAL LIM ITE 3 4 1 1 18 14 12 26 ∞ 10 8 14 0 2 TION ATTENUA 12 10 ∞ 2 8 0 6 2 12 10 ∞ 3 8 6 14 4 2 12 0 ∞ 10 4 8 6 4 0 2 (BRIDGE A) 2 INPUTS 3 (BRIDGE B) G E REMOT SIGNAL LIM ITE 3 4 1 1 18 14 12 26 ∞ 10 8 14 4 0 2 TION ATTENUA 12 10 ∞ 2 8 14 4 0 2 12 10 ∞ 3 8 6 0 14 4 2 12 ∞ 10 4 8 6 4 0 2 1 (BRIDGE A) 2 INPUTS 3 (BRIDGE B) 1 G REMOTE G Ve E REMOT SIG NAL LIM ITE R/ T 3 1 LIM ITE R/ T 1 2 3 4 18 14 26 ∞ 12 18 14 26 ∞ 1 10 8 14 4 0 2 nt 8 14 4 0 2 TION ATTENUA 12 10 ∞ 2 8 14 4 0 2 12 10 ∞ 3 8 6 0 14 4 2 12 ∞ 10 4 8 6 4 0 2 Sp TION ATTENUA 12 10 ∞ 2 8 14 4 0 2 12 10 3 8 6 0 14 4 2 12 ∞ ∞ 10 4 8 6 4 0 2 (BRIDGE A) 1 ac 2 INPUTS 3 INPUTS 3 (BRIDGE B) e 4 4 4 4 G REMOTE SIGNAL 1 LIM ITE PROTEC 1 2 3 4 18 14 12 26 ∞ 10 8 6 2 0 TION ATTENUA 12 10 ∞ 2 8 6 0 2 12 10 ∞ 3 8 6 14 4 2 0 12 ∞ 10 4 8 6 4 0 2 (BRIDGE A) 1 2 INPUTS 3 (BRIDGE B) G REMOTE SIGNA L LIM ITE 3 4 1 1 18 14 12 26 ∞ 10 8 14 0 2 TION ATTENUA 12 10 ∞ 2 8 0 14 2 12 10 ∞ 3 8 6 14 4 2 12 0 ∞ 10 4 8 6 4 0 2 (BRIDGE A) 2 INPUTS 3 (BRIDGE B) 1 TION (BRIDGE A) ATTENUA 12 10 ∞ 2 8 14 4 0 2 12 10 ∞ 3 8 6 0 14 4 2 12 ∞ 10 4 G REMOT G E SIGNAL LIM ITE 1 SIGNAL Ve 3 4 1 18 14 12 26 ∞ 10 8 14 4 0 2 nt 8 6 4 0 2 Sp ac e 4 4 A ON OF F B BRIDGE MODE B A ON OF F A ON OF F B A ON OF F B A ON OF F B A ON OF F B BRIDGE MODE B A ON OF F A ON OF F B S B A 8Ω / 4 Ω OUTPUT BR IDG E 8Ω ONLY BRIDGE 3 4 BRIDGE 2 1 WIRING CLASS 2 BRIDGE 2 1 S B 8Ω / 4 A Ω OUTPUT BR IDG E 8Ω ONLY BRIDGE 3 4 WIRING CLASS 2 S B A 8Ω / 4 Ω OUTPUT BR IDG E 8Ω ONLY BRIDGE 3 4 BRIDGE 2 1 WIRING CLASS 2 BRIDGE 2 1 S B Ω OUTPUT BRIDGE 8Ω / 4 A BR IDG 3 4 WIRING CLASS 2 S B A 8Ω / 4 Ω OUTPUT BR IDG E 8Ω ONLY BRIDGE 3 4 BRIDGE 2 1 WIRING CLASS 2 S B A 8Ω / 4 Ω OUTPUT BR IDG E 8Ω ONLY BRIDGE 3 4 BRIDGE 2 1 WIRING CLASS 2 BRIDGE 2 1 S B 8Ω / 4 A Ω OUTPUT BR IDG E 8Ω ONLY BRIDGE 3 4 WIRING CLASS 2 S B 8Ω / 4 A Ω OUTPUT BR IDG E 8Ω ONLY BRIDGE 3 4 BRIDGE 2 1 CLASS 2 WIRING Figure 19. Allow Sufficient Spacing for Adequate Ventilation XTRA Full Rack Power Amplifier Series • Reference Information 24

Extron Warranty

Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:

USA, Canada, South America, and Central America:

Extron U.S.A.

Electronics 1230 South Lewis Street Anaheim, CA 92805

Japan:

Extron Electronics, Japan Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan

Europe and Africa:

Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands

China:

Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China

Asia:

Extron Asia Pte Ltd 135 Joo Seng Road, #04-01 PM Industrial Bldg. Singapore 368363 Singapore

Middle East:

Extron Middle East Dubai Airport Free Zone F13, PO Box 293666 United Arab Emirates, Dubai This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not authorized by Extron.

NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return Authorization) number. This will begin the repair process.

USA

:

Asia

714.491.1500 or 800.633.9876 : 65.6383.4400

Europe

: 31.33.453.4040

Japan

: 81.3.3511.7655 Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions. E xtron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.

Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.

Contact Information

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF