Broadcom Emulex Poll Mode Driver for OneConnect Adapters User Guide

Broadcom Emulex Poll Mode Driver for OneConnect Adapters User Guide

Emulex® Poll Mode Driver for OneConnect® Adapters User Guide

Version 11.2

December 30, 2016 DRVPMD-OCA-UG112

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016 Corporate Headquarters San Jose, CA Website www.broadcom.com

Broadcom, the pulse logo, Connecting everything, Avago Technologies, Avago, the A logo, Emulex, and OneConnect are among the trademarks of Broadcom in the United States, certain other countries and/or the EU.

Copyright © 2015–2017 Broadcom. All Rights Reserved.

The term "Broadcom" refers to Broadcom Limited and/or its subsidiaries. For more information, please visit www.broadcom.com

.

Broadcom reserves the right to make changes without further notice to any products or data herein to improve reliability, function, or design.

Information furnished by Broadcom is believed to be accurate and reliable. However, Broadcom does not assume any liability arising out of the application or use of this information, nor the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Table of Contents Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016

Table of Contents

Chapter 1: Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.1 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.3 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.4 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Chapter 2: Configuring the Emulex PMD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2.1 Basic Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.1.1 Download the Required Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.1.2 Flash the Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.1.3 Install Linux Ethernet (be2net) Source Driver Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2.2 Build and Copy the Binaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2.1 Build the DPDK Binaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2.2 Build the Emulex SURF and PMD Binaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2.3 Copy the Binaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2.3 Parameters for the dpdk_surf.ko Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.3.1 dpdk_oce_trace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.3.2 lldp_mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.3.3 max_dpdk_oce_port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.3.4 max_rxq_per_port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.4 Creating the load_drivers and run_testpmd Scripts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.4.1 Creating the load_drivers Script . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

2.4.2 Creating the run_testpmd Script . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.5 Running a Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Chapter 3: Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3.1 Multichannel Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3.2 SR-IOV Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3.3 RHEL 7.2 with DPDK 2.0 Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Chapter 4: Tuning and Operational Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

4.1 Tunable Parameters Using DPDK Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.2 Recommended RX/TX Queues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.3 Receive and Transmit Tunings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.3.1 Tuning the Receive Function of the Emulex PMD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.3.2 Tuning the Transmit Function of the Emulex PMD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

4.3.2.1 Transmit Completion Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 4.3.2.2 Transmit Free Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 4.3.2.3 Transmit Write-Back Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

4.4 Disabling VLAN Tag Stripping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 4.5 Disabling LLDP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Broadcom - 3 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016

Chapter 1: Overview 1.1

1.2

Chapter 1: Overview Purpose

Purpose

Broadcom has partnered with 6WIND to provide an Emulex® poll mode driver (PMD) for the OCe14000-series 10Gb and 40Gb Ethernet network adapters and converged network adapters. The Emulex PMD delivers the power of the data plane development kit (DPDK) to next generation network functions virtualization (NFV) workloads, and enables customers to choose the best networking connectivity for their server deployments.

The Emulex PMD enables Ethernet (oce) adapters to interface with the DPDK, giving customers the flexibility to choose their Ethernet connectivity for standard Intel x86 platforms.

This document provides instructions for installing and configuring the DPDK, the Emulex PMD, and the Emulex SLI User Ready Framework (SURF) application programming interface (API). It also lists limitations and provides operational considerations for the Emulex PMD.

Features

The Emulex PMD includes the following features:    Concurrent Internet Small Computer Systems Interface (iSCSI) support Universal Multichannel (UMC) configuration support

PMD installation is available on all four channels per port provided that the PMD is installed on three or four channels.

Four physical functions (PFs) exist per port.

Single root input/output virtualization (SR-IOV) configuration support

On Emulex OCe14000B-series adapters, DPDK SR-IOV is not supported on the last port of the adapter.

 With receive side scaling (RSS) enabled, up to nine virtual functions (VFs) are supported with one PF in an SR-IOV configuration. In this configuration, the PMD running on the VFs has access to two RSS rings each.     With RSS disabled, up to 14 VFs are supported with one PF in an SR-IOV configuration. For more information on specifying command line parameters on the dpdk_surf.ko

module, see

Section 2.3.4, max_rxq_per_port

.

In a 4-port adapter, up to nine VFs are supported on each of the first three ports. The fourth port does not support any VFs because of limited resources.

SR-IOV-enabled systems support up to 14 VFs on each port (does not apply to HP Flex-10 systems).

HP Flex-10 systems with SR-IOV-enabled support up to eight VFs on each port.

Broadcom - 4 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016

1.3

References

  

Emulex Drivers for Linux for OneConnect Adapters User Guide.

This manual includes SR-IOV configuration information and is available on the Broadcom website.

Emulex PMD for DPDK program information. Refer to the Broadcom website.

Open source DPDK project information: http://www.dpdk.org/ Chapter 1: Overview References

1.4

Abbreviations

RSS RX SR-IOV SURF TX UMC VF VLAN VM API ARI CPU DPDK LLDP NFV NIC NPAR oce OS PF PMD RHEL application programming Interface alternative requester ID interpretation central processing unit data plane development kit Link Layer Discovery Protocol network functions virtualization network interface card NIC partitioning OneConnect Ethernet operating system physical function poll mode driver Red Hat Enterprise Linux receive side scaling receive single root I/O virtualization SLI User Ready Framework transmit universal multichannel virtual function virtual local area network virtual machine Broadcom - 5 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016

Chapter 2: Configuring the Emulex PMD

Chapter 2: Configuring the Emulex PMD Basic Setup

2.1

2.1.1

2.1.2

2.1.3

Basic Setup

NOTE

The Emulex file names in the following table and instructions are examples and may not correspond to the latest file names that may be in your OEM package or on the Broadcom website. For the latest Emulex product numbers, versions, and files, please contact your Broadcom systems engineer.

Download the Required Files

Download the following files:    dpdk-1.7.1.tar.gz

, dpdk-1.8.0.tar.gz, or dpdk-2.0

You can download these files directly from the dpdk.org website, for example: http://www.dpdk.org/browse/dpdk/snapshot/dpdk-1.8.0.tar.gz

Alternatively, you can access the files by going to http://www.dpdk.org/download and clicking

Other Versions

to see additional available files and formats from the browsing interface.

Emulex Linux Ethernet ( be2net ) source driver files ( be2net-<

build version

>.src.rpm

) These files are available in your OEM package or at the Broadcom website.

Emulex firmware ( OneConnect-Flash-11.x.xxx.x-x64.iso

)

Flash the Firmware

To flash the firmware, perform these steps: 1.

2.

3.

4.

5.

Flash the Emulex firmware to your OCe14000-series adapter using the Emulex OneConnect® Flash Utility.

Configure the OCe14000-series adapter to use the “NIC-Only” profile by using the PXE Boot BIOS.

Install Red Hat Enterprise Linux (RHEL) 6.5 64-bit, RHEL 7.0, or RHEL 7.1 64-bit with the

Software Development Workstation

option.

Log in as root, and remove the in-box be2net.ko

driver: rm /lib/modules/2.6.32-431.el6.x86_64/kernel/drivers/net/benet/be2net.ko

Reboot, log in as root, and verify that be2net.ko

is not loaded: lsmod | grep be2net

Install Linux Ethernet (be2net) Source Driver Files

To install the Linux Ethernet ( be2net ) source driver files, perform this step: On the system under test, with the appropriate file ( be2net-<

build version

>.src.rpm

) downloaded as described in

Section 2.1, Basic Setup

, install the source driver files using the rpm command to a directory of your choice. This directory corresponds to the < be2net driver directory > variable in the export command line in Section

Section 2.2.2, Build the Emulex SURF and PMD Binaries , and the

cp

command line in Section 2.2.3, Copy the Binaries

. Broadcom - 6 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016

2.2

2.2.1

2.2.2

2.2.3

Build and Copy the Binaries

Chapter 2: Configuring the Emulex PMD Build and Copy the Binaries

Build the DPDK Binaries

To build the DPDK binaries, perform this step: On the system under test, with the dpdk-<

version

>.tar.gz

file downloaded as described in

Section 2.1.1, Download the Required Files

, build the DPDK binaries. For example: cd / cp dpdk-1.8.0.tar.gz .

gunzip dpdk-1.8.0.tar.gz

tar –xvf dpdk-1.8.0.tar

cd dpdk-1.8.0

make config T=x86_64-native-linuxapp-gcc export RTE_SDK=`pwd` export RTE_TARGET=build make

Build the Emulex SURF and PMD Binaries

To build the Emulex SURF and PMD Binaries, perform this step: Use the Palau_11.x.xxx.x_DPDK_PMD_Internal.zip

file downloaded as described in

Section 2.1.1, Download the Required Files

, to build the SURF and PMD binaries. For example: cd / mkdir 11.x.xxx.0

cd 11.x.xxx.0

cp Palau_11.x.xxx.x_DPDK_PMD_Internal.zip .

unzip Palau_11.x.xxx.x_DPDK_PMD_Internal.zip

cd packages cd DPDK_PMD cd surf_linux export ELX_SURF_HUB=`pwd`/surf_hub export BE2NET= chmod 777 compile_elx_pmd_dpdk ./compile_elx_pmd_dpdk

Copy the Binaries

cd / mkdir DPDK_RH65.218.0

cd /11.x.xxx.0

cd packages cd DPDK_PMD cp surf_linux/surf_hub/surf_hub.ko /DPDK_RH65.218.0

cp surf_linux/surf_provider/surf_provider.ko /DPDK_RH65.218.0

cp surf_linux/PMD_DRIVER/librte_pmd_oce.so /DPDK_RH65.218.0

cp surf_linux/PMD_DRIVER/dpdk_oce_surf/dpdk_surf.ko /DPDK_RH65.218.0

cp //be2net.ko /DPDK_RH65.218.0 cp /dpdk-1.8.0/build/app/testpmd /DPDK_RH65.218.0

Broadcom - 7 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016

2.3

2.3.1

2.3.2

2.3.3

2.3.4

Parameters for the dpdk_surf.ko Module

Chapter 2: Configuring the Emulex PMD Parameters for the dpdk_surf.ko Module When loading the dpdk_surf.ko

module, the following command line parameters may be specified.

dpdk_oce_trace

    The dpdk_oce_trace parameter specifies the display of debug traces by the dpdk_surf.ko

module: 0x0 – Module tracing disabled (default value).

0x1 – Displays debug messages.

0x2 – Displays error messages.

0x3 – Displays all messages.

lldp_mode

   The lldp_mode parameter specifies the behavior of the Link Layer Discovery protocol (LLDP) on the OCe14000-series adapter ports: 0x0 – LLDP disabled (default value).

0x1 – Enables periodic transmission of LLDP frames.

0x2 – Enables processing of input LLDP frames.

max_dpdk_oce_port

The max_dpdk_oce_port parameter is the maximum number of OCe14000-series adapter ports to support. The default is 8. The maximum value is 32.

NOTE

This parameter must be increased to a number greater than 8 when the total number of be2net network interface card (NIC) functions in a system exceed 8. The total number of be2net NIC functions present in a system must not exceed 32 to use DPDK.

max_rxq_per_port

The max_rxq_per_port parameter specifies the maximum number of receive (RX) queues per port provided to the Emulex PMD. The default value is 0.

NOTE

Because of the limited resources on an OCe14000-series adapter, creating a single RSS-enabled RX queue might fail in SR-IOV with more than nine VFs enabled per port. To support 10 to 14 VFs per port, you must request a single non-RSS RX queue by setting max_rxq_per_port to 1. This action forces the Emulex PMD to create only one non-RSS RX queue per OCe14000-series adapter port.

Broadcom - 8 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016

2.4

2.4.1

Creating the load_drivers and run_testpmd Scripts

Chapter 2: Configuring the Emulex PMD Creating the load_drivers and run_testpmd Scripts Create the following load_drivers and run_testpmd scripts to simplify the loading and execution processes.

Creating the load_drivers Script

To create the load_drivers script, perform these steps: 1.

2.

Gather the Linux Ethernet interface names for the adapter ports: cd /DPDK_RH65.218.0

insmod be2net.ko

ifconfig | grep Ethernet rmmod be2net.ko

Create the /DPDK_RH65.218.0/load_drivers script, and modify the Linux Ethernet interface names (such as $INTERFACE_1 and $INTERFACE_2 ) for your environment: #!/bin/bash # Linux SkyHawk interface names INTERFACE_1=em1 ## Modify this to match your environment!

INTERFACE_2=em2 ## Modify this to match your environment!

# Directory containing the files BINARIES=/DPDK_RH65.218.0

# Huge page allocation mkdir -p /mnt/huge mount -t hugetlbfs nodev /mnt/huge echo 128 > /sys/devices/system/node/node0/hugepages/hugepages-2048kB/nr_hugepages echo 128 > /sys/devices/system/node/node1/hugepages/hugepages-2048kB/nr_hugepages echo 128 > /sys/devices/system/node/node2/hugepages/hugepages-2048kB/nr_hugepages echo 128 > /sys/devices/system/node/node3/hugepages/hugepages-2048kB/nr_hugepages # Load the be2net driver: insmod $BINARIES/be2net.ko

# for NPAR configurations add the following delay after loading the be2net driver: sleep 2 /* For SR-IOV configurations, install the be2net driver with the required number of VFs. For RSS support, is 6 or less. If RSS is disabled, is 12 or less. */ /* Check for the file to set sriov_numvfs. */ # find /sys -name sriov_numvfs /sys/devices/pci0000:00/0000:00:02.2/0000:04:00.0/sriov_numvfs /sys/devices/pci0000:00/0000:00:02.2/0000:04:00.1/sriov_numvfs Broadcom - 9 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016 Chapter 2: Configuring the Emulex PMD Creating the load_drivers and run_testpmd Scripts /* Set the VF number for each PF interface. */ # echo > /sys/devices/pci0000:00/0000:00:02.2/0000:04:00.0/sriov_numvfs # echo >/sys/devices/pci0000:00/0000:00:02.2/0000:04:00.1/sriov_numvfs # Load the SURF hub and provider modules: insmod $BINARIES/surf_hub.ko

insmod $BINARIES/surf_provider.ko

ip link set $INTERFACE_1 up ethtool -s $INTERFACE_1 speed 10000 duplex full ip link set $INTERFACE_2 up ethtool -s $INTERFACE_2 speed 10000 duplex full /* Reduce the number of RX & TX queues that the be2net driver uses. This frees up the queues and allows the PMD to use them */ ethtool -L $INTERFACE_1 combined 1 ethtool -L $INTERFACE_2 combined 1 /*Since all traffic will be handled by the PMD, bring down the NIC driver interface */ ifconfig $INTERFACE_1 down ifconfig $INTERFACE_2 down /* Assign a trivial and unique address to the NIC interfaces to prevent a MAC address collision in the adapter’s tables */ ifconfig $INTERFACE_1 hw ether 00:00:00:00:01 ifconfig $INTERFACE_2 hw ether 00:00:00:00:02 3.

# start the DPDK SURF kernel module with RSS capability enabled by default # Up to 6 VFs are supported with RSS enabled insmod $BINARIES/dpdk_surf.ko

# Up to 12 VFs are supported with RSS disabled using the following command: # insmod $BINARIES/dpdk_surf.ko max_rxq_per_port=1 Mark the load_drivers script executable: chmod 777 /DPDK_RH65.218.0/load_drivers Broadcom - 10 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016

2.4.2

Creating the run_testpmd Script

Chapter 2: Configuring the Emulex PMD Running a Test To create the run_testpmd script, perform these steps: 1.

2.

Determine the PCI device IDs for your two adapter ports: lspci | grep Emulex Create the /DPDK_RH65.218.0/run_testpmd script: #!/bin/bash BINARIES=/DPDK_RH65.218.0

P0=0000:01:00.00

P1=0000:01:00.01

## Modify this to match your environment!

## Modify this to match your environment!

3.

./testpmd -c ff -n 3 -d /$BINARIES/librte_pmd_oce.so -w $P0 -w $P1 -- -i --nb-cores=2 --nb-ports=2 Mark the run_testpmd script executable: chmod 777 /DPDK_RH65.218.0/run_testpmd

2.5

Running a Test

To run a test with the scripts, perform these steps: 1.

2.

Verify the correct cabling: a.

b.

Connect port 0 directly to port 1 on your adapter.

If possible, verify that both link LEDs are on.

Generate the DPDK-PMD traffic: cd /DPDK_RH65.218.0

./load_drivers ./run_testpmd start tx_first <<< NOTE: Wait for about 10-15 seconds >>> stop quit

Sample Output

EAL: Detected lcore 0 as core 0 on socket 0 EAL: Detected lcore 1 as core 0 on socket 1 EAL: Detected lcore 2 as core 1 on socket 0 EAL: Detected lcore 3 as core 1 on socket 1 EAL: Detected lcore 4 as core 2 on socket 0 EAL: Detected lcore 5 as core 2 on socket 1 EAL: Detected lcore 6 as core 3 on socket 0 EAL: Detected lcore 7 as core 3 on socket 1 EAL: Detected lcore 8 as core 4 on socket 0 EAL: Detected lcore 9 as core 4 on socket 1 EAL: Detected lcore 10 as core 5 on socket 0 EAL: Detected lcore 11 as core 5 on socket 1 EAL: Detected lcore 12 as core 8 on socket 0 EAL: Detected lcore 13 as core 8 on socket 1 Broadcom - 11 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016 EAL: Detected lcore 14 as core 9 on socket 0 EAL: Detected lcore 15 as core 9 on socket 1 EAL: Detected lcore 16 as core 10 on socket 0 EAL: Detected lcore 17 as core 10 on socket 1 EAL: Detected lcore 18 as core 11 on socket 0 EAL: Detected lcore 19 as core 11 on socket 1 EAL: Detected lcore 20 as core 12 on socket 0 EAL: Detected lcore 21 as core 12 on socket 1 EAL: Detected lcore 22 as core 13 on socket 0 EAL: Detected lcore 23 as core 13 on socket 1 EAL: Support maximum 64 logical core(s) by configuration.

EAL: Detected 24 lcore(s) EAL: Setting up memory...

EAL: Ask a virtual area of 0xc800000 bytes EAL: Virtual area found at 0x7f9d18c00000 (size = 0xc800000) EAL: Ask a virtual area of 0x1000000 bytes EAL: Virtual area found at 0x7f9d17a00000 (size = 0x1000000) EAL: Ask a virtual area of 0x2000000 bytes EAL: Virtual area found at 0x7f9d15800000 (size = 0x2000000) EAL: Ask a virtual area of 0x400000 bytes EAL: Virtual area found at 0x7f9d15200000 (size = 0x400000) EAL: Ask a virtual area of 0x400000 bytes EAL: Virtual area found at 0x7f9d14c00000 (size = 0x400000) EAL: Ask a virtual area of 0x1800000 bytes EAL: Virtual area found at 0x7f9d13200000 (size = 0x1800000) EAL: Ask a virtual area of 0x400000 bytes EAL: Virtual area found at 0x7f9d12c00000 (size = 0x400000) EAL: Ask a virtual area of 0x400000 bytes EAL: Virtual area found at 0x7f9d12600000 (size = 0x400000) EAL: Ask a virtual area of 0x400000 bytes EAL: Virtual area found at 0x7f9d12000000 (size = 0x400000) EAL: Ask a virtual area of 0x400000 bytes EAL: Virtual area found at 0x7f9d11a00000 (size = 0x400000) EAL: Ask a virtual area of 0xe00000 bytes EAL: Virtual area found at 0x7f9d10a00000 (size = 0xe00000) EAL: Ask a virtual area of 0x1000000 bytes EAL: Virtual area found at 0x7f9d0f800000 (size = 0x1000000) EAL: Ask a virtual area of 0x1c00000 bytes EAL: Virtual area found at 0x7f9d0da00000 (size = 0x1c00000) EAL: Ask a virtual area of 0x4800000 bytes EAL: Virtual area found at 0x7f9d09000000 (size = 0x4800000) EAL: Ask a virtual area of 0x800000 bytes EAL: Virtual area found at 0x7f9d08600000 (size = 0x800000) EAL: Ask a virtual area of 0xc00000 bytes EAL: Virtual area found at 0x7f9d07800000 (size = 0xc00000) EAL: Ask a virtual area of 0x400000 bytes EAL: Virtual area found at 0x7f9d07200000 (size = 0x400000) EAL: Ask a virtual area of 0x1000000 bytes EAL: Virtual area found at 0x7f9d06000000 (size = 0x1000000) EAL: Ask a virtual area of 0x2000000 bytes EAL: Virtual area found at 0x7f9d03e00000 (size = 0x2000000) EAL: Ask a virtual area of 0x800000 bytes EAL: Virtual area found at 0x7f9d03400000 (size = 0x800000) EAL: Ask a virtual area of 0x400000 bytes Broadcom - 12 Chapter 2: Configuring the Emulex PMD Running a Test

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016 Chapter 2: Configuring the Emulex PMD Running a Test EAL: Virtual area found at 0x7f9d02e00000 (size = 0x400000) EAL: Ask a virtual area of 0x200000 bytes EAL: Virtual area found at 0x7f9d02a00000 (size = 0x200000) EAL: Requesting 128 pages of size 2MB from socket 0 EAL: Requesting 128 pages of size 2MB from socket 1 EAL: TSC frequency is ~2300000 KHz EAL: open shared lib //DPDK_RH65.218.0/librte_pmd_oce.so

PMD: librte_pmd_oce by 6WIND registered EAL: Master core 0 is ready (tid=26419800) EAL: Core 4 is ready (tid=fffec700) EAL: Core 5 is ready (tid=ff5eb700) EAL: Core 6 is ready (tid=febea700) EAL: Core 7 is ready (tid=fe1e9700) EAL: Core 3 is ready (tid=9ed700) EAL: Core 2 is ready (tid=13ee700) EAL: Core 1 is ready (tid=1def700) EAL: PCI device 0000:01:00.0 on NUMA socket 0 EAL: probe driver: 10df:720 librte_pmd_oce EAL: PCI device 0000:01:00.1 on NUMA socket 0 EAL: probe driver: 10df:720 librte_pmd_oce Interactive-mode selected Configuring Port 0 (socket 0) Port 0: 00:90:FA:30:97:D6 Configuring Port 1 (socket 0) Port 1: 00:90:FA:30:97:DA Checking link statuses...

Port 0 Link Up - speed 10000 Mbps - full-duplex Port 1 Link Up - speed 10000 Mbps - full-duplex Done testpmd> start tx_first io packet forwarding - CRC stripping disabled - packets/burst=32 nb forwarding cores=2 - nb forwarding ports=2 RX queues=1 - RX desc=128 - RX free threshold=0 RX threshold registers: pthresh=8 hthresh=8 wthresh=0 TX queues=1 - TX desc=512 - TX free threshold=0 TX threshold registers: pthresh=32 hthresh=0 wthresh=0 TX RS bit threshold=0 - TXQ flags=0x0 <<< NOTE: Wait for about 10-15 seconds >>> testpmd> stop Telling cores to stop...

Waiting for lcores to finish...

---------------------- Forward statistics for port 0 --------------------- RX-packets: 24013794 RX-dropped: 0 RX-total: 24013794 TX-packets: 24004546 TX-dropped: 0 TX-total: 24004546 --------------------------------------------------------------------------- ---------------------- Forward statistics for port 1 --------------------- RX-packets: 24004514 RX-dropped: 0 RX-total: 24004514 TX-packets: 24013826 TX-dropped: 0 TX-total: 24013826 --------------------------------------------------------------------------- Broadcom - 13 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016 Chapter 2: Configuring the Emulex PMD Running a Test +++++++++++++++ Accumulated forward statistics for all ports+++++++++++++++ RX-packets: 48018308 RX-dropped: 0 RX-total: 48018308 TX-packets: 48018372 TX-dropped: 0 TX-total: 48018372 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Done.

testpmd> quit Stopping port 0...done

Stopping port 1...done

bye...

Broadcom - 14 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016

Chapter 3: Limitations

The following limitations apply when installing and using the Emulex PMD.

3.1

3.2

3.3

Chapter 3: Limitations Multichannel Limitations

Multichannel Limitations

If you install the Emulex PMD on only one or two channels on the port, it must be installed on the third channel, fourth channel, or both. This installation is necessary because freeing up the resources for the first or second channel does not release the required RSS resources.

SR-IOV Limitations

The Emulex PMD has the following limitations when using SR-IOV:     With RSS enabled, up to nine VFs are supported with one PF in an SR-IOV configuration. In this configuration, the PMD running on the VFs has access to two RSS rings each. RSS is enabled by default, and the following command is typically used in the load_drivers script: # insmod $BINARIES/dpdk_surf.ko.

For additional information, see Section 2.4.1, Creating the load_drivers Script .

With RSS disabled, up to 14 VFS are supported with one PF. To disable RSS, use the following command in the load_drivers script: # insmod $BINARIES/dpdk_surf.ko max_rxq_per_port=1.

For additional information, see Section 2.4.1, Creating the load_drivers Script .

In a 4-port adapter, up to four VFs are supported on each of the first three ports. The fourth port does not support any VFs because of limited resources.

Alternative requester ID interpretation (ARI) has not been fully qualified. For SR-IOV configuration information, refer to the

Emulex Drivers for Linux for OneConnect Adapters User Guide

.

RHEL 7.2 with DPDK 2.0 Limitations

RHEL 7.2 does not compile with DPDK 2.0.

Broadcom - 15 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016 Chapter 4: Tuning and Operational Considerations Tunable Parameters Using DPDK Applications

Chapter 4: Tuning and Operational Considerations 4.1

4.2

Tunable Parameters Using DPDK Applications

DPDK applications include multiple tunable parameters. For details about these parameters, refer to the documentation at the DPDK project site: http://www.dpdk.org/

Recommended RX/TX Queues

For best performance, the Emulex PMD requires at least three pairs of receive/transmit (RX/TX) queues.

4.3

4.3.1

4.3.2

Receive and Transmit Tunings

The DPDK API includes a set of RX/TX configuration thresholds that tune the Emulex PMD receive and transmit functions.

Tuning the Receive Function of the Emulex PMD

The Emulex PMD manages the RX free threshold that is supplied in the RX queue configuration data structure at RX queue creation.

The RX Free Threshold parameter drives the notification of the replenished RX queue descriptors to the adapter by the receive function of the PMD that manages the adapter.

The receive function of the PMD notifies only accumulated RX queue entries after their total number is greater than or equal to the RX free threshold, and notifies a number of RX entries that is equal to this threshold when this situation occurs.

The value of the RX free threshold must be a multiple of the number of queue entries per central processing unit (CPU) cache line (eight RX queue entries on Intel CPUs with a 64-byte cache line).

This method minimizes the number of expensive notification operations that perform a 32-bit write access to an adapter doorbell register.

Tuning the Transmit Function of the Emulex PMD

   The Emulex PMD manages the following TX configuration parameters supplied in the DPDK API to tune the behavior of the transmit function:

TX Completion Threshold

– Can be set with the --txrst=N parameter of the testpmd application.

TX Free Threshold

– Can be set with the --txfreet=N parameter of the testpmd application.

TX Write-Back Threshold

– Can be set with the --txwt=N parameter of the testpmd application.

Broadcom - 16 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016 Chapter 4: Tuning and Operational Considerations Receive and Transmit Tunings

4.3.2.1

4.3.2.2

4.3.2.3

Transmit Completion Threshold

The TX completion threshold drives the rate at which completed TX queue entries are notified by the adapter.

The transmit function of the Emulex PMD does not systematically set the Completion bit in the TX Queue Header entry (that precedes Queue data entries) of each output packet in the TX Queue. Instead, it only sets the Completion bit when the total number of TX Queue entries supplied to the adapter with their Completion bit unset reaches the value of the TX completion threshold.

The TX completion threshold must meet the following requirements:   Be less than the number of TQ Queue entries Be a multiple of the number of TX Queue entries per CPU cache line (four TX queue entries on Intel CPUs with a 64-byte cache line).

These settings minimize the number of write-back memory accesses performed by the adapter in the TX Completion Queue, and the actual number of Completion Queue entries exchanged for a given output packet rate.

  

Transmit Free Threshold

The configuration of TX queues includes a TX Free Threshold parameter that is the number of used TX queue entries that must be reached before the transmit function of the PMD first checks for so-called “free” TX queue entries whose completion has been notified by the adapter.

The transmit function of the PMD only looks for valid entries in a TX Completion Queue associated with a TX queue when the number of used TX queue entries reaches the value of the TX free threshold.

The value of the TX Free threshold must satisfy the following requirements: Be less than the number of TX Queue entries.

Be a multiple of the number of TX Completion Queue entries per CPU cache line.

Be a multiple of the TX Completion Threshold times the number of TX Completion Queue entries per CPU cache line.

Transmit Write-Back Threshold

The TX write-back threshold drives the rate at which processed TX completion queues entries are notified to the adapter by the transmit function.

The transmit function of the PMD accumulates processed TX Completion Queue entries and notifies them only when their total number is greater than or equal to the TX Write-Back Threshold parameter. The notification includes the threshold value (minimum) when this situation occurs.

The value of the TX Write-Back Threshold parameter must be a multiple of the number of TX Completion Queue entries per CPU cache line (four 16-byte TX Completion entries on Intel CPUs with a 64-byte cache line).

This method minimizes the number of expensive notification operations that perform a 32-bit write access to an adapter doorbell register.

Broadcom - 17 -

Emulex Poll Mode Driver for OneConnect Adapters User Guide December 30, 2016

4.4

Disabling VLAN Tag Stripping

Chapter 4: Tuning and Operational Considerations Disabling VLAN Tag Stripping OCe14000-series adapters enable the VLAN tag stripping option by default. This option might cause some DPDK applications that expect virtual LAN (VLAN) tags to be included in received packets to not work properly, such as the 6WINDGate application.

This option is a port-wide setting, and disabling it requires the PMD driver to issue a command by a PF on the port. If an application requires VLAN tag stripping to be disabled on a VF, load the PMD on a PF on the port (which will issue the command).

NOTE

The Windows operating system expects VLAN tags to be stripped, so disabling the VLAN tag stripping option on a port that is running Windows virtual machines (VMs) causes issues in the Windows VM.

4.5

Disabling LLDP

Some DPDK applications may require Link Layer Discovery Protocol (LLDP) to be disabled. LLDP can only be disabled by a PF, because it is a port-wide setting. The hbacmd utility can be invoked on the host with a PF to disable LLDP on the port if it is required by a VM.