Broadcom Emulex Drivers for VMware ESXi User Guide

Broadcom Emulex Drivers for VMware ESXi User Guide
Emulex® Drivers for VMware ESXi
User Guide
Release 12.6
Broadcom
DRVVM-UG126-100
February 4, 2020
Broadcom, the pulse logo, Connecting everything, Avago Technologies, Avago, the A logo, Brocade, Emulex, ExpressLane,
and OneCommand are among the trademarks of Broadcom and/or its affiliates in the United States, certain other countries,
and/or the EU.
Copyright © 2003–2020 Broadcom. All Rights Reserved.
The term “Broadcom” refers to Broadcom Inc. and/or its subsidiaries. For more information, please visit www.broadcom.com.
Broadcom reserves the right to make changes without further notice to any products or data herein to improve reliability,
function, or design. Information furnished by Broadcom is believed to be accurate and reliable. However, Broadcom does
not assume any liability arising out of the application or use of this information, nor the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
Emulex Drivers for VMware ESXi User Guide
Table of Contents
Chapter 1: Introduction ...................................................................................................................... 5
1.1 ESXi Compatibility ....................................................................................................................................................5
1.2 Supported Guest Operating Systems .....................................................................................................................5
1.3 Abbreviations ............................................................................................................................................................6
Chapter 2: Installation ........................................................................................................................ 8
2.1 Installing the FC Driver .............................................................................................................................................8
2.1.1 Installing the FC Driver and Management Software .........................................................................................8
2.1.2 Uninstalling the FC Driver .................................................................................................................................8
2.1.3 Installing the Native Mode FC Driver esxcli Plug-In .........................................................................................8
2.2 Supported Commands..............................................................................................................................................9
2.3 Updating Drivers Using VMware Offline Bundle Media.......................................................................................10
2.4 Installing the esxcli Management Tool .................................................................................................................10
Chapter 3: Configuration ................................................................................................................. 11
3.1 ESXi Command Line Tool Transition ....................................................................................................................11
3.1.1 ESXi 6.5 and 6.7 Implementation ...................................................................................................................11
3.2 FC Driver Configuration .........................................................................................................................................11
3.2.1 Configuration Methods for FC Driver Parameters...........................................................................................12
3.2.2 Emulex ExpressLane Support ........................................................................................................................13
3.2.3 FC-SP-2 Authentication (DH-CHAP) Support .................................................................................................14
3.2.4 Trunking Support ............................................................................................................................................15
3.2.5 Dynamically Adding LUNs ..............................................................................................................................16
3.2.6 Dynamically Adding Targets ...........................................................................................................................16
3.2.7 FC Driver Module Parameters ........................................................................................................................17
3.2.8 Creating an FC Remote Boot Disk..................................................................................................................27
3.2.9 Managing Devices through the CIM Interface.................................................................................................27
3.2.10 Installing the Emulex CIM Provider ...............................................................................................................28
3.2.11 Creating, Deleting, and Displaying vPorts ....................................................................................................28
3.2.12 Configuring VVols in ESXi 6.5 and 6.7 .........................................................................................................29
Chapter 4: Troubleshooting ............................................................................................................. 30
4.1 Troubleshooting the FC Driver ..............................................................................................................................30
4.1.1 FC Driver Log Messages ................................................................................................................................33
4.1.2 FC Error Log Messages and Their Descriptions .............................................................................................34
Appendix A: esxcli Management Tool ............................................................................................ 77
A.1 Usage ......................................................................................................................................................................77
A.2 esxcli Management Commands ...........................................................................................................................78
Broadcom
DRVVM-UG126-100
3
Emulex Drivers for VMware ESXi User Guide
Appendix B: lpfc Driver BlockGuard Functionality ....................................................................... 85
B.1 Overview .................................................................................................................................................................85
B.2 Enabling BlockGuard ............................................................................................................................................86
B.3 SCSI Command Support – SCSI Operation Codes ............................................................................................86
B.4 lpfc Driver Module Parameters .............................................................................................................................87
B.4.1 lpfc_prot_mask ..............................................................................................................................................87
B.4.2 lpfc_prot_guard ..............................................................................................................................................88
Appendix C: Using the VMID Feature on a Brocade Switch......................................................... 89
Appendix D: Using the VMID Feature on a Cisco Switch ............................................................. 91
Appendix E: License Notices .......................................................................................................... 93
E.1 OpenSSL Notice .....................................................................................................................................................93
Broadcom
DRVVM-UG126-100
4
Emulex Drivers for VMware ESXi User Guide
Chapter 1: Introduction
This product supports the following Emulex® HBAs:





LPe12000-series adapters
LPe16000-series adapters
LPe31000-series adapters
LPe32000-series adapters
LPe35000-series adapters
The VMware ESXi drivers support the FC protocol.
This document explains how to install the VMware ESXi drivers on your system and how to configure the drivers’ capabilities.
The following is a partial list of configurable VMware ESXi features:







Adding LUNs and targets
Configuring driver parameters
Creating an FC remote boot disk
Managing devices through the CIM interface
Working with vPorts
Configuring VVols
Troubleshooting FC issues
NOTE:
The Emulex OneCommand® Manager application has been renamed as the Emulex HBA Manager application.
Refer to the Emulex HBA Manager User Guide and the Emulex HBA Manager for VMware vCenter User Guide for a
complete list of supported technology.
1.1 ESXi Compatibility
For information on compatible firmware versions, go to www.broadcom.com.
1.2 Supported Guest Operating Systems
The Emulex drivers support the following guest operating systems:












CentOS 6.x
CentOS 7.x
CentOS 8.x
Oracle Linux 7.x and Oracle Linux 8.x
Oracle UEKR4 and R5
OVM 3.3.3
OVM 3.4.1
RHEL 6.7 and subsequent releases
RHEL 7.1 and subsequent releases
RHEL 8.0 and subsequent releases
SLES 11 and updates, SLES 12, and updates, and SLES 15 and updates
Windows Server 2012 and R2
Broadcom
DRVVM-UG126-100
5
Emulex Drivers for VMware ESXi User Guide



Windows Server 2016
Windows Server 2019
XenServer Citrix 7.0
1.3 Abbreviations
The following table lists the acronyms and abbreviations used in this document.
Table 1: Acronyms and Abbreviations
Acronym/Abbreviation
Description
CDB
Command Descriptor Block
CS_CTL
Class-Specific Control
CT
common transport
DA_ID
destination address identifier
DH-CHAP
Diffie-Hellman Challenge Handshake Authentication Protocol
DID
Device ID
DIF
data integrity field
ELS
Extended Link Service
FA-PWWN
Fabric Assigned Port WWN
FC-GS
Fiber Channel Generic Services
FC-SP
Fibre Channel Security Protocol
FCF
Fibre Channel Forwarder
FCID
Fiber Channel Identifier
FCP
Fibre Channel Protocol
FDMI
Fabric-Device Management Interface
FLOGI
fabric login
I/O
input/output
IOCB
input/output control block
IOCTL
input/output control
IODM
I/O Device Management
IP CSUM
IP checksum
KV
key value
LBA
logical block address
LPFC
Light Pulse Fibre Channel
MB
megabyte
MSI
message signaled interrupt
N_Port
Node port
NFA
Network Flow Analysis
NPIV
N_Port ID virtualization
OB
Open Boot
OXID
Fibre Channel originator exchange
PE
protocol endpoint
PLOGI
port login
RSCN
registered state change notification
RSP
route/switch processor
Broadcom
DRVVM-UG126-100
6
Emulex Drivers for VMware ESXi User Guide
Table 1: Acronyms and Abbreviations (Continued)
Acronym/Abbreviation
Description
VASA
vSphere APIs for Storage Awareness
VIB
vSphere Installation Bundle
VMID
Virtual Machine Identifier
VPD
vital product data
vPort
virtual port
VVols
virtual volumes
XRI
Extensible Resource Indicator
Broadcom
DRVVM-UG126-100
7
Emulex Drivers for VMware ESXi User Guide
Chapter 2: Installation
This section provides information for installing the ESXi driver for the FC protocol.
2.1 Installing the FC Driver
This section provides installation information for the driver and the Emulex CIM Provider using the FC interface on ESXi
systems. Before using this product, you need a working knowledge of FC storage devices.
2.1.1 Installing the FC Driver and Management Software
The Emulex driver is available through the VMware support website. Go to the VMware support website for further details.
For VMware ESXi 6.5 and subsequent operating systems releases, you can manage adapters using the Emulex HBA
Manager application on Windows or the Emulex HBA Manager application for VMware vCenter, but you must install and use
the appropriate Emulex CIM Provider. Refer to the Emulex HBA Manager User Guide and the Emulex HBA Manager for
VMware vCenter User Guide for instructions on installing the respective applications. The installation requires that the CIM
Provider be installed. For more information on installing the CIM Provider, refer to the Emulex CIM Provider Installation
Guide.
NOTE:
Before installing the management application, you must install the FC driver from the VMware website and then
reboot the server.
Before installing the FC driver and CIM Provider, verify that the firmware version is correct. If it is, proceed with the
installation. If it is not, update the firmware using the Emulex HBA Manager application from a Windows server or
the Emulex HBA Manager application for VMware vCenter, and reboot the system before proceeding with the
installation.
2.1.2 Uninstalling the FC Driver
Go to the VMware Patch Download page on the VMware website for instructions.
2.1.3 Installing the Native Mode FC Driver esxcli Plug-In
This section describes the installation and usage of the esxcli plug-in for the native mode FC (lpfc) driver on ESXi 6.5 and
ESXi 6.7 systems. This diagnostic tool is for the FC driver module.
NOTE:
You can download the esxcli plug-in from the Broadcom® website.
To install the esxcli elxfc plug-in for ESXi 6.5 and ESXi 6.7, perform the following steps:
1. Unzip and copy the following file to /var/log/vmware/ on the ESXi host:
EMU-esx-6.x.x-elxlpfccli-<VIB_version>-offline_bundle-<OS_version>.zip
2. On the ESXi host, install the VIB as follows:
esxcli software vib install -d /<pathname>/EMU-esx-6.x.x-elxlpfccli-<VIB_version>
-offline_bundle-<OS_version>.zip
Broadcom
DRVVM-UG126-100
8
Emulex Drivers for VMware ESXi User Guide
3. Restart the hostd using the following command:
/etc/init.d/hostd restart
After the hostd has restarted, the elxfc namespace appears under esxcli.
2.2 Supported Commands
The following command is supported on elxfc:
esxcli elxfc
Usage:
esxcli elxfc <cmd> <cmd options>
Table 2: Available Namespaces
Namespace
Description
adapter
Adapter information of an Emulex FC HBA
bginjerr
Blockguard error injection page information of an Emulex FC HBA
dhchap
Authentication information of an Emulex FC adapter
event
Events information of an Emulex FC HBA
eventsnap
Events information with snap after display of an Emulex FC HBA
fcf
FCF table information of an Emulex FC HBA
heap
Heap usage statistics and information of an Emulex FC HBA
iostat
I/O statistics information of an Emulex FC HBA
kv
KV page information of an Emulex FC HBA
logmessage
Log message of an Emulex FC HBA in vmkernel.log
lun
SAN LUN information of an Emulex FC HBA
memlog
Memlog information of an Emulex FC HBA
memory
Memory statistics and information of an Emulex FC HBA
mgmt
Management statistics and information of an Emulex FC HBA
modinfo
Module information of an Emulex FC/FCoE HBA
node
Nodes in SAN information of an Emulex FC HBA
param
Dynamic configuration parameter information of an Emulex FC HBA
port
Port information and statistics of an Emulex FC HBA
rsnn
Symbolic node name information of an Emulex FC HBA
sli4q
sli4q information of an Emulex FC HBA
target
SAN targets information of an Emulex FC HBA
vmid
VMID page information of an Emulex FC HBA
Table 3: Available Commands
Command
Description
list
Lists Emulex FC adapter instance names.
xlane
Emulex FC HBA instances ExpressLane™ information
Broadcom
DRVVM-UG126-100
9
Emulex Drivers for VMware ESXi User Guide
2.3 Updating Drivers Using VMware Offline Bundle Media
VMware recommends using the offline bundle to update software on VMware ESXi 6.5 and ESXi 6.7 platforms.
NOTE:
For more information about the ESXi patch management activities, go to the VMware website.
To update a driver using the offline bundle media, perform the following steps:
1. Run the following command to update the FC driver.
esxcli software vib install --maintenance-mode -d <pathname>/VMW-ESX-6.x.x-lpfc
-<driver_version>-offline-bundle-<OS_version>.zip
where <driver_version> represents the FC driver.
2. Reboot the VMware ESXi server to activate the drivers.
2.4 Installing the esxcli Management Tool
The esxcli management tool is delivered as an offline bundle for the esxcli plug-in.
To install the esxcli management tool in ESXi 6.5 and ESXi 6.7, perform the following steps:
1. Copy the offline bundle to the ESXi host.
2. On the ESXi host, install the offline bundle as follows:
esxcli software vib install -d /<pathname>/EMU-esx-6.x.x-elxmgmt-<VIB_version>
-offline_bundle-<OS_version>.zip
3. Restart the hostd using the following command:
/etc/init.d/hostd restart
Broadcom
DRVVM-UG126-100
10
Emulex Drivers for VMware ESXi User Guide
Chapter 3: Configuration
This chapter provides configuration information for the ESXi driver.
3.1 ESXi Command Line Tool Transition
For the ESXi 6.5 release and all subsequent ESXi operating system releases, VMware is transitioning from esxcfg
commands to esxcli commands. This section describes the transition to the esxcli commands.
NOTE:
Both sets of commands are supported in the ESXi 6.5 and ESXi 6.7 releases.
3.1.1 ESXi 6.5 and 6.7 Implementation
For ESXi 6.5 and subsequent ESXi operating system releases, Broadcom uses the esxcli version of the command
sequence, which has a different command syntax than the earlier releases. Some examples follow.
The command syntax to list the supported parameters by a driver:
~ # esxcli system module parameters list -m <driver binary name>
The command syntax for setting a parameter to a driver module:
~ # esxcli system module parameters set -p <parameter_string> -m <driver binary name>
3.1.1.1 FC Driver Example
To set extended logging for the Emulex FC driver:
~ # esxcli system module parameters set -p lpfc_log_verbose=0x10c3 -m lpfc
To list the parameter values assigned to a driver module:
~ # esxcli system module parameters list -m lpfc
This command is the same as listing parameters. The parameter set has the value column completed if applicable. This
command lists all instance and global parameters, which makes it necessary to watch for any altered driver parameters.
3.2 FC Driver Configuration
You can configure driver parameters using native ESXi tools, the Emulex HBA Manager application (for use in non-lockdown
mode only), or the Emulex HBA Manager for VMware vCenter Server application (for use in both lockdown and
non-lockdown modes).
This section describes how to configure parameters using native ESXi tools. For a more comprehensive description of ESXi
tools, go to the VMware public website. If you have further questions, contact a VMware technical support representative.
Refer to the Emulex HBA Manager User Guide and the Emulex HBA Manager Command Line Interface User Guide for
information about the Emulex HBA Manager application.
Refer to the Emulex HBA Manager for VMware vCenter User Guide for information about the Emulex HBA Manager for
VMware vCenter Server application.
Broadcom
DRVVM-UG126-100
11
Emulex Drivers for VMware ESXi User Guide
3.2.1 Configuration Methods for FC Driver Parameters
Configure the driver parameters using any of the following methods:




Permanent (global)
Permanent (per adapter)
Temporary (global)
Temporary (per adapter)
The Emulex HBA Manager application supports all four methods to configure driver parameters. Refer to the Emulex HBA
Manager User Guide or the Emulex HBA Manager for VMware vCenter User Guide for more information.
The native ESXi tools support only permanent configuration methods for the driver parameters. The following section
provides further information on permanent configuration methods.
3.2.1.1 Permanent FC Configuration Methods Using Native ESXi Tools
Permanent configuration requires that the new values be saved in the ESXi environment. These changes are considered
permanent because they persist across system reboots.
See Section 3.2.7, FC Driver Module Parameters, for parameter names and values. Parameter values are in both
hexadecimal and decimal.
NOTE:
For ESXi systems, the following steps must be executed from the Troubleshooting Administrative Shell
environment. If your configuration does not provide access to this shell, refer to VMware’s vSphere or VMware’s
vCenter server manual for enabling driver logging. Alternatively, refer to the Emulex CIM Provider Installation
Guide for driver logging.
To make changes that impact all adapters in the system (global changes):
1. From the Troubleshooting Administrative Shell environment’s terminal window, type:
esxcli system module parameters set -p "param1=value param2=value ..." -m lpfc
NOTE:
Use quotation marks around the parameter values only when listing two or more.
2. Reboot the server, type:
reboot
NOTE:
VMware does not officially support unloading the driver using vmkload_mod -u. If you must unload the driver,
contact a VMware technical support representative.
The NPIV port creation and deletion are performed by the VMware vSphere client or Virtual Center service. Refer
to the VMware documentation for more information.
3.2.1.1.1 Example of Permanent Global Configuration
The following example sets lun_queue_depth (the maximum number of commands that can be sent to a single LUN) to
20 (the default is 30) for all adapters in your system.
1. Locate the parameter lpfc_lun_queue_depth in Table 4.
2. Set the permanent value by typing:
esxcli system module parameters set -p lpfc_lun_queue_depth=20 -m lpfc
Broadcom
DRVVM-UG126-100
12
Emulex Drivers for VMware ESXi User Guide
3. To reboot the server, type:
reboot
The new setting is used when the driver reloads.
To verify the setting, type:
esxcli system module parameters list -m lpfc
3.2.1.1.2 Examples of Permanent Per-Adapter Configuration
The following example sets lun_queue_depth to 20 (the default is 30) for adapter 1.
1. Set the adapter-specific value by typing:
esxcli system module parameters set -p lpfc1_lun_queue_depth=20 -m lpfc
2. To reboot the server, type:
reboot
The new setting is used when the driver is reloaded.
To verify the setting, type:
esxcli system module parameters list -m lpfc
The following example sets lun_queue_depth to 20 (the default is 30) for adapter 1 and lun_queue_depth to 10 (the
default is 30) for adapter 2.
1. Set the adapter-specific value by typing:
esxcli system module parameters set -p "lpfc1_lun_queue_depth=20, lpfc2_lun_queue_depth=10" -m lpfc
NOTE:
Type the command all on one line without a carriage return.
2. To reboot the server, type:
reboot
The new settings are used when the driver is reloaded.
To verify the settings, type:
esxcli system module parameters list -m lpfc
3.2.2 Emulex ExpressLane Support
The host servers do not distinguish between lower and higher priority workloads being sent to LUNs. For flash storage
deployed in mixed storage environments, the combination of data from rotating media and flash devices can cause
congestion on the network and reduced performance for the flash storage devices.
The ExpressLane feature enables special priority queuing for selected LUNs (ExpressLane LUNs). ExpressLane LUN
performance is superior to that of regular LUNs. Mixed storage environments can use ExpressLane to alleviate congestion,
reduce latency, and improve throughput, ensuring that key applications receive highest priority. Switches can provide up to
three priority levels; Low, Medium, and High.
Broadcom
DRVVM-UG126-100
13
Emulex Drivers for VMware ESXi User Guide
The following requirements must be met to use ExpressLane:



ExpressLane is not supported on the LPe12000-series adapters.
An ExpressLane LUN must be enabled in the driver before it can be used by OneCommand Manager. Additionally, the
priority value to mark each of the ExpressLane frames must be specified to the FC driver through the appropriate driver
parameters.
ExpressLane is not supported for LUNs attached to virtual ports.
For additional information, refer to the Emulex HBA Manager for VMware vCenter User Guide.
3.2.3 FC-SP-2 Authentication (DH-CHAP) Support
NOTE:

DH-CHAP is available only for physical ports, not for virtual ports.

The authentication driver parameters are only available on local hosts and not for any remote hosts.

Boot from SAN is not supported when DH-CHAP authentication is enabled.

DH-CHAP is not supported on FA-PWWN ports.

DH-CHAP is not supported if Dynamic D_Port is enabled.
Fibre Channel Security Protocol (FC-SP-2) DH-CHAP is a secret-based authentication and key management protocol that
uses the CHAP algorithm augmented with an optional Diffie-Hellmann algorithm with hash priority (MD5 and SHA1).
You can configure FC-SP-2 DH-CHAP authentication between an adapter and a switch.
FC-SP-2 DH-CHAP authentication is disabled by default. To enable FC-SP-2 DH-CHAP authentication, you must pass the
lpfc_enable_auth parameter to the driver by typing the following command:
# esxcli system module parameters set -p lpfc_enable_auth=1 -m lpfc
You must reboot the system to activate the parameter.
After DH-CHAP has been activated and configured, you can manually initiate authentication per adapter. For more
information on manually initiating authentication, refer to the Emulex HBA Manager User Guide.
You can get, set, update, or delete a password using the Emulex HBA Manager application. For details on how to perform
these operations, refer to the Emulex HBA Manager User Guide.
You can also display authentication configuration using the keyval page and esxcli.
For example, in the keyval page, type:
/usr/lib/vmware/vmkmgmt_keyval/vmkmgmt_keyval
-i vmhba4/Emulex
-g -k
auth
An output similar to the following is shown:
Key 'auth':
Authentication info: Authentication enabled
local WWPN 10:00:00:90:fa:c7:c2:a8
remote WWPN ff:ff:ff:ff:ff:ff:ff:ff
ff:ff:ff:ff:ff:ff:ff:ff is the switch port name.
Broadcom
DRVVM-UG126-100
14
Emulex Drivers for VMware ESXi User Guide
3.2.4 Trunking Support
NOTE:

Before you enable or disable trunking on the Emulex adapter, follow the instructions from Brocade to enable or
disable trunking on the switch.

Dynamic D_Port cannot co-exist with the trunking feature (also called FC port aggregation) on
LPe35000-series adapters. If trunking is enabled, the firmware automatically disables Dynamic D_Port.

FA-PWWN and Dynamic D_Port cannot co-exist with the trunking feature on LPe35000-series adapters. If
trunking is enabled, the firmware automatically disables FA-PWWN and Dynamic D_Port.

Trunking is only supported on LPe35000-series adapters.

Trunking is not supported at 8 Gb/s speeds, and the link will not come up at this speed.
Trunking enables you to combine multiple physical FC links to form a single logical link (aggregated port). The aggregated
port’s maximum link speed is the sum of the maximum link speeds of the individual physical links comprising the aggregated
port. For example, an aggregated port comprised of two physical links running at 32 Gb/s each will have a potential logical
(aggregate) link speed of 64 Gb/s. The actual link speed of the aggregated port depends on the states (active or non-active)
of the individual physical links comprising the aggregated port.
The physical links comprising an aggregated port are referred to as lanes. Only 2-lane and 4-lane aggregated ports are
supported. For LPe35002 adapters, only 2-lane port aggregation is possible. If 2-lane port aggregation is configured on an
LPe35002 adapter, the two physical links are combined to form a single 2-lane aggregated port whose aggregate speed is
potentially 64 Gb/s, assuming both physical links are active.
LPe35004 adapters support both 2-lane port aggregation and 4-lane port aggregation. If 2-lane port aggregation is
configured on an LPe35004 adapter, the four physical links on the adapter will be divided among two separate aggregated
ports. The two lowest numbered physical links will form the first aggregated port, and the two highest number physical links
will form the second aggregated port. If 4-lane port aggregation is configured on an LPe35004 adapter, all four physical links
will be combined to form a single 4-lane trunk whose aggregate speed is potentially 128 Gb/s, assuming all 4 links are active.
There are no driver parameters to enable trunking. Trunking is a one-time configuration, and the configuration is performed
through the Emulex HBA Manager application. For more information on configuring trunking, refer to the Emulex HBA
Manager User Guide.
When trunking is configured for an adapter, Internal loopback and External loopback tests are supported. For more
information on running loopback tests, refer to the Emulex HBA Manager User Guide.
You can view the existing trunk links using esxcli elxmgmt.
An example of an LPe35002 adapter, showing 2-lane port aggregation with a single SCSI host follows:
# esxcli elxmgmt trunkinfo get -w 10:00:00:10:9b:41:73:8c
Trunking Mode: 2-lane trunking
Trunk Port 0: Logical Link Speed: 64 Gbs
Physical Link 0: Active
Physical Link 1: Active
An example of an LPe35004 adapter, showing 2-lane port aggregation with a single SCSI host follows.
# esxcli elxmgmt trunkinfo get -w 10:00:00:10:9b:65:dd:24
Trunking Mode: 2-lane trunking
Trunk Port 0: Logical Link Speed: 64 Gbs
Broadcom
DRVVM-UG126-100
15
Emulex Drivers for VMware ESXi User Guide
Physical Link 0: Active
Physical Link 1: Active
Trunk Port 2: Logical Link Speed: 64 Gbs
Physical Link 2: Active
Physical Link 3: Active
An example of an LPe35004 adapter, showing 4-lane port aggregation with a single SCSI host follows.
# esxcli elxmgmt trunkinfo get -w 10:00:00:10:9b:65:dd:24
Trunking Mode: 4-lane trunking
Trunk Port
Physical
Physical
Physical
Physical
0: Logical Link Speed: 128 Gbs
Link 0: Active
Link 1: Active
Link 2: Active
Link 3: Active
3.2.5 Dynamically Adding LUNs
For instructions on dynamically adding LUNs, refer to the Using Rescan section of the VMware SAN Configuration
documentation.
3.2.6 Dynamically Adding Targets
VMware does not provide a native mechanism for dynamically adding targets. After all target and LUN configuration steps
have been successfully completed, add the target to the intended fabric zone.
To get the driver to log into the target, either the target or initiator link must be bounced. If the target is configured with security
ACLs, the same link bounce requirement applies after the security ACLs are corrected.
To force the ESXi server to rescan all devices, perform one of these actions:

Run the following command:
esxcli storage core adapter rescan -A vmhbaX

From the vSphere Client, select Configuration Tab > Storage Adapters, and then click Rescan All.
Broadcom
DRVVM-UG126-100
16
Emulex Drivers for VMware ESXi User Guide
3.2.7 FC Driver Module Parameters
Table 4 lists the FC driver module parameters, their descriptions, and their corresponding values in ESXi native mode.
Dynamic parameters do not require a system reboot for changes to take effect.
NOTE:
Refer to the VMware periodicals for quick boot instructions.
Table 4: FC Driver Parameters
ESXi 6.5 and
ESXi 6.7 Native
Mode Driver
Model Values
Module Parameter
Description
lpfc_compression_log
Defines how often the
Default = 300
compression logs are written Min. = 5
(in seconds).
Max.= 86,400
This parameter is
dynamically updated.
The driver uses this parameter to
periodically write status messages to the
vmkernel log. The messages provide state
analysis on the paths, targets, and adapter.
It differs from throttle in that the throttle stops
the driver from spamming the logs on a very
high frequency failure.
lpfc_delay_discovery
Delays N_Port discovery
Default = 0
when the Clean Address bit Min. = 0
is cleared.
Max. = 1
This parameter requires a
system reboot or quick boot.
When the parameter is set to 0, no delay is
added to the initial discovery.
When this parameter is set to 1, initial Nport
discovery is delayed by RA_TOV seconds
when the Clean Address bit is cleared in
FLOGI/FDISC accept and the FCID/Fabric
name/Fabric port name is changed.
lpfc_devloss_tmo
The number of seconds the Default = 10
driver holds I/O waiting for a Min. = 1
lost device to return.
Max. = 255
This parameter is
dynamically updated.
—
lpfc_discovery_threads
The maximum number of
Default = 32
ELS commands that can be Min. = 1
outstanding during
Max. = 64
discovery.
This parameter requires a
system reboot or quick boot.
—
lpfc_enable_auth
Enables or disables
DH-CHAP authentication.
The possible values are:
 0 = Authentication is
disabled (default).
 1 = Authentication is
enabled.
This parameter is
dynamically updated.
Default 0 =
Disable
Min. 0 = Disable
Max. 1 = Enable
lpfc_enable_bb_credit_recovery Toggles the Buffer-to-Buffer Default = 1
Credit Recovery feature.
Min. = 0
This parameter requires a
Max. = 1
system reboot or quick boot.
Broadcom
Comments
NOTE: DH-CHAP and Dynamic D_Port are
mutually exclusive. If both features are
enabled simultaneously, warning messages
will result. You must either disable
DH-CHAP using the lpfc_enable_auth
parameter, or disable Dynamic D_Port using
the Emulex HBA Manager application.
Applicable to SLI-4 adapters only.
DRVVM-UG126-100
17
Emulex Drivers for VMware ESXi User Guide
Table 4: FC Driver Parameters (Continued)
Module Parameter
Description
ESXi 6.5 and
ESXi 6.7 Native
Mode Driver
Model Values
lpfc_enable_da_id
Controls the DA_ID CT
command. Unregisters
objects with the fabric
nameserver.
Default 1 =
Enable
Min. 0 = Disable
Max. 1 = Enable
lpfc_enable_fc4_type
Default = 0
Enables the FC4 type
supported. Valid values are: Min. = 0
 0 = Register FCP only
Max. = 3
(for LPe32000-series
adapters); Register both
FCP and NVMe (for
LPe35000-series
adapters)
 1 = Register FCP only
 3 = Register both FCP
and NVMe
This parameter requires a
system reboot or quick boot.
This parameter must be explicitly enabled
for LPe32000-series adapters, and is
enabled by default on LPe35000-series
adapters.
lpfc_xri_split
When enabled, this
Default = 50%
parameter defines the
Min. = 10%
division of XRI resources
Max. = 90%
between SCSI and NVMe.
This parameter is only used if
the value of the
lpfc_enable_fc4_type
parameter is 3—register both
FCP and NVMe and the port
is not configured for NVMeT.
The supported values are in
percentages. The
lpfc_xri_split value is
the percentage of XRI
resources allocated to the
SCSI port. The remaining
percentage of XRI resources
is allocated to NVMe.
The supported range is 10%
to 90%, The default value is
50%.
This parameter requires a
system reboot or quick boot.
This parameter is supported on
LPe32000-series and LPe35000-series
adapters.
lpfc_enable_fcp_priority
Enables or disables FCP
Default = 0
priority.
Min. = 0
This parameter requires a
Max. = 1
system reboot or quick boot.

Enables MDS diagnostics.
This parameter is
dynamically updated.
Enables or disables the Cisco Fibre
Channel Link Diagnostics feature.
NOTE: The parameter should be disabled
(set to 0) after diagnostics are complete.
lpfc_enable_mds_diags
Broadcom
0 = Disabled
(default)
1 = Enabled
Comments
—

0 = Do not use the nodelist priority table
(default).
1 = Use the nodelist priority table.
DRVVM-UG126-100
18
Emulex Drivers for VMware ESXi User Guide
Table 4: FC Driver Parameters (Continued)
ESXi 6.5 and
ESXi 6.7 Native
Mode Driver
Model Values
Module Parameter
Description
lpfc_enable_qfull
Enable the driver's
Default = 1
lun_queue_depth ramp
Min. = 0
down and ramp up
Max. = 1
functionality when the SCSI
device status is Task Set Full
(x28).
 When enabled (value =
1), the Emulex driver
gradually reduces the
LUN queue depth with
each Task Set Full status
completion, and then
ramps back up as the I/O
successfully completes.
 When disabled (value =
0), the driver takes no
action when an I/O
completes with a Task
Set Full status.
This parameter is
dynamically updated.
Disabling this parameter has a potential
impact on the overall VM performance.
Consult your target vendor for guidance.
lpfc_enable_rrq
Enables Reinstate Recovery Default = 2
Qualifier functionality.
Min. = 0
 0x0 = Disabled,
Max. = 2
XRI/OXID use not
tracked.
 0x1 = XRI/OXID reuse is
timed with the resource
allocation timeout
(R_A_TOV), Reinstate
Recovery Qualifier sent.
 0x2 = XRI/OXID reuse is
timed with R_A_TOV;
no reinstate recovery
qualifier is sent.
This parameter requires a
system reboot or quick boot.
—
lpfc_EnableXLane
Enable ExpressLane.
Def = 0
This parameter requires a
Min = 0
system reboot or quick boot. Max = 1
1 = Enable ExpressLane
0 = Disable ExpressLane
NOTE: If the
lpfc_vmid_priority_tagging
parameter is enabled, EnableXLane is
disabled as both the features conflict in
using CS_CTL field in FC header.
Broadcom
Comments
DRVVM-UG126-100
19
Emulex Drivers for VMware ESXi User Guide
Table 4: FC Driver Parameters (Continued)
ESXi 6.5 and
ESXi 6.7 Native
Mode Driver
Model Values
Module Parameter
Description
lpfc_XLanePriority
ExpressLane CS_CTL
Def = 0x0
Priority.
Min = 0x0
Sets the CS_CTL field in the Max = 0x7F
FC header.
Refer to the switch vendor
administration guide for
additional information.
This parameter requires a
system reboot or quick boot.
—
lpfc_enable_SmartSAN
Enables SmartSAN
functionality. The function
works with FDMI-2 to provide
enhanced fabric diagnostics.
This parameter requires a
system reboot or quick boot.
—
lpfc_external_dif
Enables external DIF support 0 = Disabled
on select devices.
1 = Enabled
(default)
This parameter requires a
system reboot or quick boot.
External DIF is not available for
LPe12000-series adapters.
lpfc_fcp_class
Selects the FC class of
Default = 3
service for FCP sequences. Min. = 2
This parameter requires a
Max. = 3
system reboot or quick boot.
—
lpfc_fdmi_on
Default = 1
Controls FDMI support.
 0 = FDMI support off.
Min. = 0
 1 = FDMI support on.
Max. = 1
This parameter requires a
system reboot or quick boot.
If enable_SmartSAN is set 1, the driver
automatically supports FDMI-2. If
enable_SmartSAN is set 0, the driver uses
the current value of fdmi_on to provide
FDMI support – 0 meaning no support or 1
meaning FDMI-1 support.
If FDMI-2 fails, the driver falls back to
FDMI-1. If enable_SmartSAN is set to 1,
the driver ignores the fdmi_on value and
goes directly to FDMI-2 support.
Traditional FDMI support means the driver
will assume FDMI-2 support; however, if that
fails, it falls back to FDMI-1.
lpfc_first_burst_size
First burst size for targets
that support first burst.
This parameter is
dynamically updated.
—
Broadcom
Default = 0
disable
Min. = 0 disable
Max. =1 enable
Default = 0
Min. = 0
Max. = 65,536
Comments
DRVVM-UG126-100
20
Emulex Drivers for VMware ESXi User Guide
Table 4: FC Driver Parameters (Continued)
ESXi 6.5 and
ESXi 6.7 Native
Mode Driver
Model Values
Module Parameter
Description
lpfc_hba_queue_depth
The maximum number of
Default = 8,192
FCP commands queued to Min. = 32
an FC adapter.
Max. = 8,192
The driver automatically
adjusts the
hba_queue_depth to
match adapter capabilities.
This setting may be
overridden.
This parameter requires a
system reboot or quick boot.
—
lpfc_iocb_cnt
IOCBs allocated for ELS, CT, Default = 1
and abort sequence in 1024 Min. = 1
increments.
Max. = 5
This parameter requires a
system reboot or quick boot.
—
lpfc_link_speed
Selects link speed. Valid
values are:
 0 = Auto select
 2 = 2 Gigabaud
 4 = 4 Gigabaud
 8 = 8 Gigabaud
 16 = 16 Gigabaud
 32 = 32 Gigabaud
This parameter is
dynamically updated.
Default = 0
Min. = 0
Max. = 32
For ESXi 6.5 and above, link_speed can
only be changed using the driver parameter
on LPe12000-series adapters.
NOTE: Setting this option incorrectly can
cause the adapter to fail to initialize.
lpfc_log_verbose
Verbose logging bit-mask.
This parameter is
dynamically updated.
Default = 0
Min. = 0
Max. = 0x7fffffff
—
lpfc_lun_queue_depth
The maximum number of
Default = 30
FCP commands that can
Min. = 1
queue to a specific LUN.
Max. = 254
NOTE: The driver
dynamically limits the
runtime lun_queue_depth
setting to 1/8th of the
hba_queue_depth to
prevent I/O starvation. An
attempt to set the
lun_queue_depth higher
than the 1/8th setting results
in a failure. The console logs
and the adapter KeyVal page
reflects the failure.
This parameter is
dynamically updated.
Broadcom
Comments
—
DRVVM-UG126-100
21
Emulex Drivers for VMware ESXi User Guide
Table 4: FC Driver Parameters (Continued)
ESXi 6.5 and
ESXi 6.7 Native
Mode Driver
Model Values
Module Parameter
Description
lpfc_max_heap_size
Maximum allowable memory Default = 128 MB —
consumption per server for Min. = 64 MB
the LPFC module.
Max. = 512 MB
This parameter requires a
system reboot or quick boot.
lpfc_max_luns
The maximum number of
Default = 65,535 Setting in ESXi 6.5 and 6.7 allows for sparse
LUNs allowed.
LUN IDs above 256.
Min. = 1
This parameter requires a
Max. = 65,535
system reboot or quick boot.
lpfc_max_multiq
Sets how many completion Default = 4
queues the driver is
Min. = 0
requesting from ESXi for
Max. = 8
each HBA instance.
Each completion queue uses
an MSI-X vector.
0 indicates disabled
Multi-Queue.
This parameter requires a
system reboot or quick boot.
Sets the number of MultiQ FCP I/O
channels. The driver sets this parameter to
determine how many completion queues to
use per HBA port. Each completion queue
consumes an MSI-X vector and defaults to a
low number to ensure systems with large
amount of HBAs do not run out of vectors.
lpfc_max_scsicmpl_time
Default = 0
Uses the SCSI command
completion time to control
Min. = 0
queue depth to the device. Max. = 60,000
 0 = SCSI command
completion time is not
used for controlling I/O
queue depth.
 N = I/O queue depth is
controlled to limit the I/O
completion time to N ms.
This parameter is
dynamically updated.
—
lpfc_max_targets
The maximum number of
Default = 256
discovered targets allowed. Min. = 0
This parameter requires a
Max. = 4096
system reboot or quick boot.
A driver parameter to adjust the supported
target count.
lpfc_max_vmid
Maximum number of VMs to Default = 8
be tagged. The range is 4 to Min. = 4
255.
Max. = 255
This parameter requires a
system reboot or quick boot.
This value indicates the number of VMIDs
supported.
lpfc_mem_tracker
Turns memory tracking on or 0 = Disabled
(default)
off. Valid values are:
 1 = On
1 = Enabled
 0 = Off
This parameter requires a
system reboot or quick boot.
Keeps track of driver heap and slab
allocation/free. It is used only when
debugging driver memory issues.
Broadcom
Comments
DRVVM-UG126-100
22
Emulex Drivers for VMware ESXi User Guide
Table 4: FC Driver Parameters (Continued)
ESXi 6.5 and
ESXi 6.7 Native
Mode Driver
Model Values
Module Parameter
Description
lpfc_nlp_slab_cnt
NLP slab entries.
Default = 128
This parameter requires a
Min. = 32
system reboot or quick boot. Max. = 256
lpfc_ras_fwlog_buffsize
Buffer size to be allocated in
host memory for firmware
logging.
This parameter requires a
system reboot or quick boot.
lpfc_ras_fwlog_level
Firmware logging level. Valid Default = 0
only if firmware logging is
Min. = 0
enabled.
Max. = 4
This parameter requires a
system reboot or quick boot.
This parameter is supported only on
LPe31000-series, LPe32000-series, and
LPe35000-series adapters.
lpfc_rb_slab_cnt
Receives buffer slab entries. Default = 256
This parameter requires a
Min. = 32
system reboot or quick boot. Max. = 256
Controls the maximum number of receive
buffers that will be posted to the adapter.
lpfc_scan_down
Start scanning for devices
Default = 1
from the highest AL_PA to
Min. = 0
the lowest.
Max. = 1
This parameter requires a
system reboot or quick boot.
—
Broadcom
Comments
Controls the size of the driver’s node table.
This table in turn limits the driver’s ability to
discover remote ports, fabrics, initiators, and
targets in a zone.
This parameter is supported only on
Default = 0
LPe31000-series, LPe32000-series, and
Min. = 0
LPe35000-series adapters.
Max. = 4
The possible
values are:
 0 = Disable
firmware log
written to the
host memory
(default)
 1 = ¼ MB
(256K) host
memory to be
allocated for
the firmware
log
 2 = ½ MB
(512K) host
memory to be
allocated for
the firmware
log
 3 = ¾ MB
(768K) host
memory to be
allocated for
the firmware
log
 4 = 1 MB host
memory to be
allocated for
the firmware
log
DRVVM-UG126-100
23
Emulex Drivers for VMware ESXi User Guide
Table 4: FC Driver Parameters (Continued)
ESXi 6.5 and
ESXi 6.7 Native
Mode Driver
Model Values
Module Parameter
Description
lpfc_sg_seg_cnt
The maximum scatter gather Default = 64
segment count for DMA.
Min. = 64
The maximum data allowed Max. = 4096
in one SG element is
0x80000000.
This parameter requires a
system reboot or quick boot.
—
lpfc_suppress_link_up
Default = 0
Suppresses link up at
initialization:
Min. = 0
 0x0 = Bring up link
Max. = 2
 0x1 = Do not bring up link
 0x2 = Never bring up link
This parameter requires a
system reboot or quick boot.
Enable this parameter to assist with SAN
issues during ESXi boot.
lpfc_suppress_rsp
Negotiates whether to
suppress the RSP
from a target during a
PLOGI.
This parameter is
dynamically updated.
Default = 1
Min. = 0
Max. = 1
Applicable to SLI-4 adapters only.
lpfc_task_mgmt_tmo
The maximum time to wait
for task management
commands to complete.
This parameter is
dynamically updated.
Default = 60
Min. = 5
Max. = 180
—
lpfc_tgt_queue_depth
The maximum number of
Default = 65,535 The upper threshold is determined by the
FCP commands queued to a Min. = 10
adapter's capability.
specific target port.
Max. = 65,535
This parameter is
dynamically updated.
lpfc_throttle_log_cnt
Do not exceed this number of Default = 10
Logging mechanism intended to speed up
messages logged within
issue diagnosis by reducing the need to
Minimum = 1
throttle_log_time.
Maximum = 1000 enable driver logging.
This parameter is
dynamically updated.
lpfc_throttle_log_time
Do not exceed
throttle_log_cnt
number of logs within this
time limit (seconds).
This parameter is
dynamically updated.
Broadcom
Default = 1
Min. = 1
Max. = 60
Comments
Works with throttle_log_cnt.
DRVVM-UG126-100
24
Emulex Drivers for VMware ESXi User Guide
Table 4: FC Driver Parameters (Continued)
ESXi 6.5 and
ESXi 6.7 Native
Mode Driver
Model Values
Module Parameter
Description
lpfc_topology
Selects FC topology. Valid
Default = 0
values are:
Min. = 0
 0x0 = Attempt loop mode Max. = 6
then point-to-point
 0x01 = Internal loopback
mode
 0x02 = Attempt
point-to-point mode only
 0x04 = Attempt loop
mode only
 0x06 = Attempt
point-to-point mode then
loop
This parameter is
dynamically updated.
This parameter is supported only on
LPe12000-series and LPe16000-series
adapters.
lpfc_use_adisc
Use address discovery on
Default = 0
rediscovery, initiated by
Min. = 0
RSCN, to authenticate FCP Max. = 1
devices instead of port login.
This parameter is
dynamically updated.
—
lpfc_use_msi
Default = 2
Uses preferred MSI-X
interrupt mode, if possible. Min. = 0
 0 = MSI disabled (INTx
Max. = 2
mode)
 1 = MSI enabled
 2 = MSI-X enabled
This parameter requires a
system reboot or quick boot.
—
lpfc_vmid_app_header
VMID Application ID tagging. 0 = Disabled
(default)
This parameter requires a
system reboot or quick boot. 1 = Enabled
Brocade® VMID uses the application
service header field to communicate the
capability.
lpfc_vmid_inactivity_timeout
Inactivity timeout duration in Default = 4
hours. The range is 0 to 24. Min. = 0
This parameter is
Max. = 24
dynamically updated.
VMID is an ID assigned per VM. The VMID
is removed when a VM is inactive for
lpfc_vmid_inactivity_timeout
duration.
The lpfc_vmid_inactivity_timeout
value is in hexadecimal.
Broadcom
Comments
DRVVM-UG126-100
25
Emulex Drivers for VMware ESXi User Guide
Table 4: FC Driver Parameters (Continued)
ESXi 6.5 and
ESXi 6.7 Native
Mode Driver
Model Values
Module Parameter
Description
lpfc_vmid_priority_tagging
VMID CS_CTL tagging.
Default = 0
This parameter requires a
Min. = 0
system reboot or quick boot. Max. = 2
NOTE:
Comments
Cisco VMID uses the priority tagging field to
communicate the capability.
 0 = Disables priority tagging. Priority
tagging is also disabled when the
parameter is set to anything other than
1 or 2.
 1 = Enables priority tagging only for
targets that support it in their PLOGI
LS_ACC response.
 2 = Enables priority tagging for all
targets, whether they support it in their
PLOGI LS_ACC response.
The values in Table 5 and Table 6 are taken from the FC-GS FC Standard documents and are passed to the switch
through FC-CT commands. Adapter port attributes are provided for each adapter port. Adapter attributes are
provided once for each adapter, no matter the number of ports.
Table 5: Adapter Port Attributes for fdmi_on Parameter
Hexadecimal Value
Information Type
0x001
Supported FC-4 Types
0x002
Supported Speed
0x003
Current Port Speed
0x004
Maximum Frame Size
0x005
Operating System Device Name
0x006
Host Name
0x007
Node Name
0x008
Port Name
0x009
Port Symbolic Name
0x00A
Port Type
0x00B
Supported Classes of Service
0x00C
Port Fabric Name
0x00D
Port Active FC-4 Types
0x101
Port State
0x102
Number of Discovered Ports
0x103
Port Identifier
Table 6: Adapter Attributes for fdmi_on Parameter
Hexadecimal Value
Information Type
0x001
Node Name
0x002
Manufacturer
0x003
Serial Number
Broadcom
DRVVM-UG126-100
26
Emulex Drivers for VMware ESXi User Guide
Table 6: Adapter Attributes for fdmi_on Parameter (Continued)
Hexadecimal Value
Information Type
0x004
Model
0x005
Model Description
0x006
Hardware Version
0x007
Driver Version
0x008
Option ROM Version (boot code)
0x009
Firmware Version
0x00A
Operating System Name and Version
0x00B
Maximum CT Payload Length
0x00C
Node Symbolic Name
3.2.8 Creating an FC Remote Boot Disk
For instructions on creating an FC remote boot disk, refer to the VMware SAN configuration documentation.
3.2.9 Managing Devices through the CIM Interface
VMware on the Visor-based ESXi platforms uses the CIM interface as the only standard management mechanism for device
management.
3.2.9.1 Using the Emulex HBA Manager GUI
For VMware ESXi 6.5 and 6.7 hosts, you can manage adapters using the Emulex HBA Manager application on Windows,
but you must install and use the appropriate Emulex CIM Provider.
NOTE:
If advanced adapter management capabilities are required (for example, disabling a port), use the Emulex HBA
Manager application for VMware vCenter.
When Windows Emulex HBA Manager is used to manage HBAs installed on ESXi 6.7 Update 1, most of the features are
unavailable. This is due to recent changes made by VMware to its SFCB daemon.
The following table lists the features that are functional and nonfunctional when Windows Emulex HBA Manager is used to
manage HBAs discovered on ESXi 6.7 Update 1.
Functional
Nonfunctional
Discovery
SetPortSpeed
Port Attributes
SetPortEnabled
Hba Attributes
EnableBootCode
Port Statistics
Diagnostics
Server Attributes
WWN Management
DriverParams
Dump
GetXCVRdata
Get IPL File Name
Pcidata
Firmware Download
VPD
Firmware Parameters
Trunking
Broadcom
DRVVM-UG126-100
27
Emulex Drivers for VMware ESXi User Guide
Instead of Emulex HBA Manager for Windows, use the Emulex HBA Manager for VMware CLI (elxvcpcmd) or the esxcli
elxmgmt utilities to manage HBAs installed on ESXi 6.7 Update 1.
3.2.9.2 Using the Emulex HBA Manager for VMware vCenter
The Emulex HBA Manager for VMware vCenter Server application uses the standard CIM interface to manage the adapters
and supports CIM-based device and adapter management. The Emulex HBA Manager for VMware vCenter Server
application also supports existing adapter management functionality based on its proprietary management stack and the
standard HBA API interface. To manage adapters (including updating the firmware) on an ESXi 6.5 or 6.7 host using the
Emulex HBA Manager for VMware vCenter Server application, you must install the out-of-box Emulex CIM Provider on the
host.
For more information on installing the Emulex HBA Manager for VMware vCenter Server application and enabling the CIM
Provider, refer to the Emulex HBA Manager for VMware vCenter User Guide.
NOTE:

For the ESXi 6.7 vSphere Web client, flex is not supported, so you must use the vSphere client, HTML.
Currently the vSphere client, HTML supports only limited functionality.

For LPe35000-series adapters only:
In some cases, a firmware update requires either a firmware reset or a basic PCIe reset, depending on the
features available in the new firmware. A firmware reset is performed automatically if it is needed, regardless
of the operating system. In some cases, a full reboot is required to activate new firmware or to enable a new
feature. In that case, a message similar to one of the following messages appears after the firmware download
is complete:
Download successfully completed. Please reboot the system to activate new
firmware.
Download completed. Some features require an optional reboot. Refer to the
Adapter's Firmware and Boot Code Release Notes for details.
For a list of features that require a reboot to be enabled, refer to the Emulex LPe35000-Series HBA Firmware
and Boot Code Release Notes.
3.2.10 Installing the Emulex CIM Provider
Refer to the Emulex CIM Provider Installation Guide for instructions on installing the Emulex CIM Provider.
3.2.11 Creating, Deleting, and Displaying vPorts
The Emulex driver for VMware supports NPIV by default. ESXi provides the only management API for creating and deleting
a vPort and creating an NPIV-enabled VM. vPorts in the driver discover the fabric just like physical ports do, and are subject
to the same SAN delays. As the number of vPorts increases, the amount of time it takes to complete remote port discovery
increases because the vPorts are created sequentially and each vPort executes discovery synchronously. If your
NPIV-enabled virtual machines power-on automatically, powering on could take longer than usual. This behavior is normal
for NPIV virtual machines.
Broadcom
DRVVM-UG126-100
28
Emulex Drivers for VMware ESXi User Guide
The following note applies to vPorts.
NOTE:

Ensure you are using the latest recommended firmware for vPort functionality. Check the Broadcom website
for the latest firmware.

Loop devices and NPIV are not supported on the same port at the same time. If you are running a loop topology
and you create a vPort, the vPorts link state is offline. VMware ESXi supports fabric mode only.

You can create vPorts only on 8, 16, and 32 GFC adapters.

The Emulex HBA Manager application sees all vPorts created by the driver, but the application has read-only
access to them.
3.2.12 Configuring VVols in ESXi 6.5 and 6.7
The Emulex native mode FC driver supports the VVols feature released with ESXi 6.5 and 6.7. VMware’s VVols feature
allows for dynamic provisioning of storage, based upon the needs of a VM. VM disks, also called VVols, allow VMware
administrators to manage storage arrays through the API. Arrays are logically partitioned into storage containers. VVols are
stored natively in the storage containers. I/O from ESXi to the array is managed through an access point or PE and the
storage provider.
3.2.12.1 Storage Containers
Storage containers are a logical abstraction and hold groups of VVols that are physically provisioned in the storage array.
Storage containers are an alternative to traditional storage based upon LUNs or NFA shares. Storage containers are set up
by a storage administrator. Storage container capacity is based on physical storage capacity. The minimum is one storage
container per array, and the maximum number depends upon the array. One storage container can be simultaneously
accessed through multiple PEs. When the storage provider and PEs are in place, the storage container is visible to ESXi
hosts.
3.2.12.2 Protocol Endpoints
A PE is an access point that enables communication between an ESXi host and a storage array system. A PE is not a
datastore; it is the I/O transport mechanism to access the storage container. A PE is part of the physical storage fabric. A
PE is created by a storage administrator.
3.2.12.3 Storage Providers
Storage providers are also referred to as VASA providers. Out-of-band communication between vCenter and the storage
array is achieved through the storage provider. The storage provider creates the VVols.
For more information about VVols and instructions on configuring VVols, refer to the VMware and target vendor-supplied
documentation.
Broadcom
DRVVM-UG126-100
29
Emulex Drivers for VMware ESXi User Guide
Chapter 4: Troubleshooting
Your system may operate in an unexpected manner in certain circumstances. This chapter explains many of these
circumstances and offers one or more workarounds for each situation.
4.1 Troubleshooting the FC Driver
This section provides troubleshooting information for the FC driver.
Table 7 identifies some of the common situations and their potential resolutions.
Table 7: Troubleshooting the FC Driver
Situation
Resolution
The port link fails to come up.
If an FC link fails to come up, verify that the adapter is connected to a supported device.
The supported 8GFC adapters are:
 2GFC
 4GFC
 8GFC
The supported 16GFC adapters are:
 4GFC
 8GFC
 16GFC
The supported 32GFC adapters are:
 8GFC
 16GFC
 32GFC
The Emulex driver is not loaded, and all
paths are down.
Use the lspci utility to determine whether the Emulex ports are being properly identified. If
they are not being properly identified, determine if the driver ISO was correctly installed. You
must have the correct driver for the installed adapter because the device PCI IDs are
installed with the driver package.
Examine the /var/log/vmkernel.log file for lpfc log messages indicating an error. If you
specified driver logging (see Section 3.2, FC Driver Configuration), make sure that you
spelled the driver parameters correctly. The ESXi module subsystem does not load the driver
on reboot if the parameters are not spelled correctly. In this case, contact Broadcom Technical
Support.
All paths are down.
Use the driver's KV pages to get critical information.
First check the link state. The KV command shown in the footnote shows the driver's current
link, and whether it has found a fabric and the link speed.a
If the data shows Link Up Ready and Mode Online, check the discovered nodes. Fabric,
initiator, and target types show the SAN as it was presented and discovered by the driver.
Additionally, if you are experiencing a periodic path outage, the command shown in the
second footnote in a script loop shows if the node status is changing or if the node is going
offline.b
If your target or initiator is not in the driver's discovered list, check your zone membership and
the state of all zone members.
Contact Broadcom Technical Support if you are unable to resolve missing zone members.
Broadcom
DRVVM-UG126-100
30
Emulex Drivers for VMware ESXi User Guide
Table 7: Troubleshooting the FC Driver (Continued)
Situation
Resolution
The FC driver fails to recognize an adapter Download and install the adapter firmware that complies with the minimum supported version
and logs unknown IOCB messages in the (or later) listed on the Broadcom website at www.broadcom.com.
system log during driver load. The adapter
is running outdated firmware.
The system panics when booted with a
failed adapter installed.
Remove the failed adapter and reboot.
The FC driver does not discover all remote
ports in the configuration switch zone.
Some initiators or targets may appear to be
missing.
Evaluate your switch zone. Count how many entries are there and add at least seven more
(to account for fabric logins). If the sum exceeds 128, you must increase the driver's node
table size. The following commands increase it to 200 entries. See Section 3.2, FC Driver
Configuration, for more information on this driver parameter.
Globally:
esxcli system module parameters set -p lpfc_nlp_slab_cnt=200 -m lpfc
Per instance:
esxcli system module parameters set -p lpfc0_nlp_slab_cnt=200 -m lpfc
A reboot is required.
Broadcom
DRVVM-UG126-100
31
Emulex Drivers for VMware ESXi User Guide
a.
Data from KV command 1:
[root@chara:~] /usr/lib/vmware/vmkmgmt_keyval/vmkmgmt_keyval -i vmhba3/Emulex -k adapter -g
Key 'adapter':
lpfc Adapter Page
Emulex LightPulse FC SCSI 11.0.206.6000
Emulex LPe12002-M8 8Gb 2-port PCIe Fibre Channel Adapter on PCI bus 0000:04 device 00 fn 1 port 1 Link
Speed: 8 Gb
BoardNum:
3
FW Version:
2.02X11
HW Version:
31004549
ROM Version:
5.12a5
SerialNum:
VM21932214
Vendor Id:
f10010df
SLI Rev: 3
MQ: Unavailable
NPIV Supported: VPIs max 255 VPIs used 0
RPIs max 4096 RPIs used 18
IOCBs inuse 0
XRIs max 4096 FCP 320
FCP BDEs max 66 DMA buf size 1008
Queue Depth
LUN
HBA FCP
IOCB max 16
txq cnt 0
txq max 0
txcmplq 0
30
2048
PCI read error: 0 retry attempts: 0
Link Up - Ready:
EDTOV 2000 ms RATOV 10 sec
PortID 0x20700
Fabric
Current speed 8G
WWPN 10:00:00:00:c9:f4:48:af
WWNN 20:00:00:00:c9:f4:48:af
Mode: Online
Broadcom
DRVVM-UG126-100
32
Emulex Drivers for VMware ESXi User Guide
b. Data from KV command 2:
[root@chara:~] /usr/lib/vmware/vmkmgmt_keyval/vmkmgmt_keyval -i vmhba11/Emulex -k node -g
Key 'node':
lpfc Node page:
WWNN
10:00:00:05:33:a6:a8:bb
10:00:00:05:33:a6:a8:bb
00:00:00:00:00:00:00:00
20:00:00:00:c9:f3:f9:b6
20:00:00:00:c9:f4:48:af
20:00:00:90:fa:02:19:16
20:00:00:90:fa:02:19:17
20:00:00:90:fa:5d:2f:29
20:00:00:90:fa:5d:2f:31
20:00:00:90:fa:5d:92:2f
20:00:00:11:0d:e0:54:00
20:06:00:11:0d:19:9a:00
20:07:00:11:0d:19:9b:00
WWPN
ScsiID DID
20:06:00:05:33:a6:a8:bb
xfffffe
21:fc:00:05:33:a6:a8:bb
xfffffc
00:00:00:00:00:00:00:00
xfffffd
10:00:00:00:c9:f3:f9:b6
x021600
10:00:00:00:c9:f4:48:af
x020700
10:00:00:90:fa:02:19:16
x021500
10:00:00:90:fa:02:19:17
x020e00
10:00:00:90:fa:5d:2f:29
x020902
10:00:00:90:fa:5d:2f:31
x020903
10:00:00:90:fa:5d:92:2f
x02094a
20:00:00:11:0d:e0:54:00
0 x02090e
20:06:00:11:0d:19:9a:00
1 x021000
20:07:00:11:0d:19:9b:00
2 x021100
Type
Status
Fabric
Node ok
Fabric
Node ok
Fabric
Node logged out
Initiator
Node ok
Initiator
Node ok
Initiator
Node ok
Initiator
Node ok
Initiator
Node ok
Initiator
Node ok
Initiator
Node ok
Target
Node ok
Target
Node ok
Target
Node ok
4.1.1 FC Driver Log Messages
Log messages have traditionally been organized into logical groups based on code functionality in the FC driver. With the
introduction of the latest Emulex adapters, that grouping is modified to account for additional behaviors. The traditional
grouping is maintained, but recently added messages are no longer grouped together.
The messages provided in this section are unmaskable error conditions. They are automatically added to the system console
log.
You can examine the /var/log/vmkernel.log file to view any of these messages. If you have concerns, the best policy
is to run a vm-support dump and contact VMware or Broadcom Technical Support.
Log messages are organized into logical groups based on code functionality within the driver. Each group consists of a block
of 100 log message numbers. Most groups require a single block of 100 message numbers; however, some groups (INIT,
FCP) require two blocks.
Table 8 lists the groups and defines the associated number ranges.
Table 8: Message Log Table
LOG Message Verbose Mask Definition
Verbose Bit
Verbose Description
LOG_ELS
0x00000001
ELS events
LOG_DISCOVERY
0x00000002
Link discovery events
LOG_MBOX
0x00000004
Mailbox events
LOG_INIT
0x00000008
Initialization events
LOG_LINK_EVENT
0x00000010
Link events
LOG_MGMT_ERROR
0x00000020
IODM management error logging
LOG_FCP
0x00000040
FCP traffic history
LOG_NODE
0x00000080
Node table events
LOG_BG
0x00000200
BlockGuard events
LOG_MEM_HEAP
0x00000400
Memory tracker heap logging
LOG_SLI
0x00000800
SLI events
Broadcom
DRVVM-UG126-100
33
Emulex Drivers for VMware ESXi User Guide
Table 8: Message Log Table (Continued)
LOG Message Verbose Mask Definition
Verbose Bit
Verbose Description
LOG_FCP_ERROR
0x00001000
Log errors, not underruns
LOG_LIBDFC
0x00002000
Libdfc events
LOG_VPORT
0x00004000
NPIV events
LOG_MEM_SLAB
0x00008000
Memory tracker slab logging
LOG_EVENT
0x00010000
CT,TEMP,DUMP, logging
LOG_AUTH
0x00020000
DH CHAP logging
LOG_FCP_UNDER
0x00040000
FCP underruns errors
LOG_TASKMGMT
0x00100000
Task management events
LOG_MGMT
0x00200000
IODM management trace logging
LOG_SCSI_CMD
0x00400000
ALL SCSI commands
LOG_EDIF
0x00800000
External DIF events
LOG_ESXCLI
0x04000000
Log esxcli messages
LOG_ALL_MSG
0x7fffffff
LOG all messages
The following is an example of a LOG message:
lpfc_sli4_read_config:8989: 0:2003 cfg params Extents
In the preceding LOG message:




lpfc – Identifies the driver binary
sli4_read_config – Identifies the function generating the log
0 – Identifies the Emulex port number
2003 – Identifies the LOG message number
NOTE:
If the word Data: is present in a LOG message, any information to the right of Data: is intended for Broadcom
Technical Support or Engineering use only.
Unless otherwise noted in the ACTION: attribute, report these errors to Broadcom Technical Support. Broadcom
requests that when reporting occurrences of these error messages, you provide a tarball of all vmkernel files in
/var/log.
4.1.2 FC Error Log Messages and Their Descriptions
3031 Delay authentication for <seconds>
Authentication is delayed because there is a fabric change.
ACTION: No action required.
3642 Read Object mailbox cmd failed with <status> <add_status> <mbx status> <shdr_status>
<shdr_add_status> <mb_sts>
Authentication read from the flash memory failed.
ACTION: Upgrade the firmware or report the error to Broadcom Technical Support.
3088 Read Object abnormal exit <rc>
No authentication configured.
ACTION: Need to configure authentication. Refer to the Emulex Drivers for VMware ESXi User Guide for instructions.
Broadcom
DRVVM-UG126-100
34
Emulex Drivers for VMware ESXi User Guide
3042 No Authentication configuration found for request
No authentication configured.
ACTION: Need to configure authentication, Refer to the Emulex Drivers for VMware ESXi User Guide for instructions.
0264 FDMI cmdcode <cmdcode> not supported
Driver sends an invalid FDMI command.
ACTION: Report the error to Broadcom Technical Support.
0257 GID_FT Query error <ulpStatus> <Reason code> retries
GID_FT to the NameServer is failing and this can cause target discovery.
ACTION: Check the port connection and the switch configuration.
0267 NameServer GFF Rsp <DID> Error <Status> <Reason code>
GFF to the NameServer is failing and this can cause target discovery.
ACTION: Check the port connection and the switch configuration.
<fc_ns_retry>
Data <fc_flag> <fc_rscn_id_cnt>"
6435 E2E FDMI RPA failure
FDMI command to the management server is failing for end-to-end to End management feature.
ACTION: Switch may not support End to End management support. Upgrade the switch or report the error to Broadcom Technical Support.
4927 Failed Mbuf Alloc cnt <size> <index>
Failed to allocate DMA buffer.
ACTION: Check the ESX host configuration and memory usage to free up some resources.
5941 Failed Heap Alloc of DMABuf , cnt <count> i <index>
Failed to allocate DMA buffer.
ACTION: Check the ESX host configuration and memory usage to free up some resources.
4673 UNSOL CT Rsp err <rc> Data: <fc_flag>
Uable to send reject for unhandled end-to-end management commands.
ACTION: No action required.
0241 NameServer Rsp Error Data .<CmdRsp> <ReasonCode> <Explanation> <fc_flag>
GID_FT to the NameServer is failing.
ACTION: Check the port connection and the switch configuration.
0268 NS cmd <cmdcode> Error <ulpStatus> <Reason code>
CT command is failing with error status.
ACTION: Check the port connection and the switch configuration.
0266 Issue NameServer Req <cmdcode> err <rc> Data: <fc_flag> <fc_rscn_id_cnt>
Failed to issue command to NameServer.
ACTION: Check the port connection and the switch configuration.
7902 Failed to alloc CT RSP for DID <DID> size <rsp_size> cmd <cmdcode>
Failed to allocate memory for the CT command.
ACTION: Check the ESX host configuration and memory usage to free up some resources.
Broadcom
DRVVM-UG126-100
35
Emulex Drivers for VMware ESXi User Guide
9021 Failed to issue IOCB
Failed to issue IOCB command to the firmware.
ACTION: Report the error to Broadcom Technical Support.
7062 VMID cmdcode <cmdcode> not supported
Invalid VMID CT command.
ACTION: Report the error to Broadcom Technical Support.
7157 Failed Gen_Req status <status>
Failed to send CT command.
ACTION: Check the port connection and the switch configuration.
3056 set not supported - Persistent topology settings in place.
Cannot change topology, persistent topology is enabled.
ACTION: No action required.
2699 Misconfigured FA-WWN - Attached device does not support FA-WWN
The HBA port is configured to use FA-WWN, but the attached device does not support it.
ACTION: Report the error to Broadcom Technical Support.
3177 EEPROM failure - Event Data1: <event_data1> Event Data2: <event_data2>
EEPROM failure occurred on the HBA.
ACTION: No action required.
2019 FW does not support persistent topology Using driver parameter defined value <topology>
The firmware does not support persistent topology, using driver parameter defined value.
ACTION: No action required.
2021 Invalid topology values from FW Using driver parameter defined value <>
Invalid topology values from firmware, using driver parameter defined value <topology>.
ACTION: No action required.
4202 EDC rsp error - sending RDF for FPIN only.
Exchange Diagnostic Capabilities (EDC) response error, using RDF for FPIN.
ACTION: No action required.
4919 Unknown Desc Tag <tag>
Unknown Exchange Diagnostic Capabilities (EDC) descriptor tag.
ACTION: Report the error to Broadcom Technical Support.
4657 FPIN CONGESTION <Notification> type <FPIN_TYPE> (<type>) Event Duration <evt_period> mSecs
Lost Credit and Credit Stall and driver recovering.
ACTION: Check the port connection and the switch configuration.
2516 CGN SET_FEATURE mbox failed with status <shdr_status> add_status <shdr_add_status>, mbx status
<mbxStatus> Reset Congestion to FPINs only
Enable Congestion SIGNAL feature in firmware is failing.
ACTION: Report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
36
Emulex Drivers for VMware ESXi User Guide
0136: PLOGI completes to NPort <DID> completion
PLOGI completes to NPort completion.
ACTION: No action required.
0137: No retry ELS command <ELS_CMD> to remote
No retry ELS command that is sent to remote node
ACTION: No action required.
0237: Pending Link Event during Discovery: State <hba_state>
Received link event during discovery. Causes discovery restart.
ACTION: No action required, unless this issue persists. If persistent, check cabling.
4678: Unknown FPIN <descriptor tag> - Reject
Unknown FPIN descriptor tag.
ACTION: No action required.
0034 Unable to send mailbox
Either the driver could not allocate resources or it could not send sparam_mbox or cfglink_mbox.
ACTION: Attempt to unload and reload the driver when it is convenient.
0127: ELS timeout
An ELS IOCB command was posted to a ring and did not complete within ULP timeout period.
ACTION: If no ELS command is going through the adapter, reboot the system. If this issue persists, contact Broadcom Technical Support.
2858 FLOGI failure
The fabric rejected an FLOGI.
ACTION: Reconfigure the switch and check connection. If this issue persists, contact Broadcom Technical Support.
0125: FDISC Failed <Reject Error>. Fabric out of resources
The fabric rejected an FDISC because the switch cannot support additional virtual ports.
ACTION: Reconfigure the switch to support more NPIV logins. If this issue persists, contact Broadcom Technical Support.
0125: FDISC Failed <Reject Error>. Fabric Detected Bad WWN
The fabric rejected an FDISC because the switch detected a bad WWN.
ACTION: No action required.
2851 Attempt link reset
A link reset is being attempted.
ACTION: No action required.
0138: ELS rsp: Cannot issue reg_login for <DID>
REG_LOGIN mailbox command failed.
ACTION: Ensure the adapter firmware is current. Reload the driver.
2853 Failed to issue INIT_LINK mbox command
The mailbox command to enable an asynchronous event notification failed.
ACTION: Ensure the adapter firmware is current. Reload the driver.
Broadcom
DRVVM-UG126-100
37
Emulex Drivers for VMware ESXi User Guide
2852 Failed to allocate mbox memory
Mailbox allocation error.
ACTION: No action required
3334 Delay fc port discovery for <n> seconds
Delay the node port discovery since fabric parameters changed.
ACTION: No action required.
2556: UNREG_VFI mbox allocation failed HBA state <port_state>
Could not allocate memory for UNREG_VFI mailbox command.
ACTION: No action required.
2557: UNREG_VFI issue mbox failed rc <rc> HBA state <port_state>
Could not issue the UNREG_VFI mailbox command.
ACTION: No action required.
0113: An FLOGI ELS command <elsCmd> was received from DID <did> in Loop Mode
While in Loop Mode, an unknown or unsupported ELS command was received.
ACTION: Check device DID.
0111 Dropping received ELS cmd
The driver decided to drop an ELS response ring entry.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
0115: Unknown ELS command <elsCmd> received from NPORT <did>
Received an unsupported ELS command from a remote N_Port.
ACTION: Check the remote N_Port for a potential issue.
0289: Issue Register VFI failed <ret_val>
The driver could not register the virtual fabric index for the Fibre Channel Forwarder Indicator (FCFI).
ACTION: Check the switch and port configurations.
0915 Register VPI failed : Status: <stauts> upd bit <upd_bit value>
Could not register the VPI.
ACTION: No action required.
2881: RRQ failure DID:<did> Status:<status_value>
A driver Reinstate Recovery Qualifier request failed.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
4110 Issue PLOGI <deferred_did> deferred on NPort <d_id> rpi <rpi> Data: <ndlp_ptr>
Defer the processing of issue PLOGI until outstanding UNREG_RPI mailbox completes.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
38
Emulex Drivers for VMware ESXi User Guide
2831 FLOGI response with cleared Fabric bit fcf_index <fcf_index> Switch Name <switch_name> Fabric
Name <fabric_name>
When the driver completed a FLOGI, the common service parameters did not indicate an FPort or N_Port remote node. The driver treats
this issue as an error.
ACTION: Validate the external cable connection and FPort/Nport configuration. If this issue persists, report the error to Broadcom
Technical Support.
3094 Start rport recovery on sadapter id <sdapter_hostnum> fc_id <d_id> vpi <vpi> rpi <rpi> xri <xri>
state <node_state> flags <node_flags>
Recover a port that failed a BLS ABTS request.
ACTION: Check the remote N_Port. Driver would issue LOGOUT to the remote N_Port as part of recovery process.
2882: RRQ completes to N_Port <value> with no ndlp. Data: <status> <reason> <iotag>
The driver completes a Reinstate Recovery Qualifier, but no node association exists.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
0348: NameServer login: node freed
The enable mode failed to free up the nameserver login.
ACTION: No action required.
4532 UVEM LS_RJT <data 0> <data1>
VMID UVEM got an LS reject.
ACTION: Check switch configration.
4533 UVEM error status <ulpStatus>
VMID UVEM got an error.
ACTION: Check switch configuration.
<ulpWord>
0249: Cannot issue Register Fabric login: Err <err>
The firmware could not issue the fabric REG_LOGIN command; the error value is unique for each possible failure.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
6529 QFPA failed with status %x
VMID QFPA got an LS reject.
ACTION: Check switch configuration.
%x , irsp->ulpStatus, irsp->un.ulpWord[4]);
6528 QFPA LS_RJT %x %x , data[0], data[1]);
VMID QFPA got an error.
ACTION: Check switch configuration.
0649 Cannot issue Register Fabric login: Err <err>
The firmware could not issue the fabric REG_LOGIN command for SLI4 adapter. The error value is unique for each possible failure.
ACTION: This is a software driver error. Report the error to Broadcom Technical Support.
2756: LOGO failure DID:<DID> Status:<Status>/<Extended Status>.
An N_Port logout to <DID> failed either by the driver, the firmware, or the target. The <status> and <extended status> indicate why the
N_Port logout failed.
ACTION: Check the remote N_Port functionality. If the issue persists, report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
39
Emulex Drivers for VMware ESXi User Guide
2754: PRLI failure DID:<DID> Status:<Status>/<Extended Status>.
A process login to <DID> failed either by the driver, the firmware, or the target. The <status> and <extended status> indicate why the
process login failed.
ACTION: Check the remote N_Port functionality. If the issue persists, report the error to Broadcom Technical Support.
2755: ADISC failure DID:<DID> Status:<Status>/<Extended Status>.
An address discovery to <DID> failed either by the driver, the firmware, or the target. The <status> and <extended status> indicate why
the address discovery failed.
ACTION: If the issue persists, report the error to Broadcom Technical Support.
2753: PLOGI failure DID:<DID> Status:<Status>/<Extended Status>.
A port login to <DID> was failed either by the driver, the firmware, or the target. The <status> and <extended status> indicate why the port
login failed.
ACTION: Check the remote N_Port functionality. If the issue persists, report the error to Broadcom Technical Support.
2732: Failed to issue INIT_VPI mailbox command.
The driver wanted to send a INIT_VPI mailbox command to initialize a vPort, but it failed to send the mailbox command due to the state
of the adapter.
ACTION: No action required.
0126: FDISC failed (ulpStatus/ulpWord[4])
The extended link service (ELS) F_Port discovery command has failed.
ACTION: Check the port and switch configuration.
0255: Issue FDISC: no IOCB
All of the pre-allocated IOCBs are in use.
ACTION: No action required.
0254 Register VPI: no memory);
Out of memory while registering vPort.
ACTION: No action required.
0256 Issue FDISC: Cannot send IOCB);
Unable to issue a fabric IOCB command.
ACTION: No action required.
0251 NameServer login: no memory);
Memory allocation failed during PLOGI.
ACTION: No action required.
0253 Register VPI: Can't send mbox);
Unable to send mailbox command while registering a new VPort with the HBA.
ACTION: No action required.
0252 Cannot issue NameServer login);
Memory allocation failed during PLOGI.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
40
Emulex Drivers for VMware ESXi User Guide
7105 failed to allocate mailbox memory);
Memory allocation for mailbox failed.
ACTION: No action required.
0820 FLOGI Failed <lsRejErr> BBCredit Not Supported
FLOGI failed as the other endpoint was not ready/busy.
ACTION: No action required.
1305 Link Down Event <Event_Tag> received Data: <fc_event_tag> <port_state> <flags>
Link down event was received.
ACTION: Check the connectivity between the fabric nodes.
1306 Link Up Event in loop back mode <event_tag> received Data: <fc_event_tag> <flags>
Link up event in the loopback mode was received.
ACTION: No action required.
1303 Link Up Event <event_tag> received Data: <fc_event_tag> <flags>
Link up event was received.
ACTION: No action required.
0231 RSCN timeout Data: <fc_ns_retry> <LPFC_MAX_NS_RETRY>
RSCN timeout occurred during discovery.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
0230 Unexpected timeout, hba link state <link_state>
Unexpected timeout occurred during discovery.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
0545 lpfc_create_static_vport bad information header <signature> <rev>
Invalid header fields while creating vPort.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
2524 Failed to get the non-embedded SGE virtual address
Unable to obtain correct non-embedded SGE virtual address.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
0546 lpfc_create_static_vport failed to create vport <status> <wwpn> < wwnn>
Failed to create vport.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
1836 Could not issue unreg_login(all_rpis) <status>
Could not issue unreg login.
ACTION: No action required.
0543 lpfc_create_static_vport failed to allocate vport_info);
Out of memory while allocating vPort information.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
41
Emulex Drivers for VMware ESXi User Guide
0542 lpfc_create_static_vport failed to allocate mailbox memory);
Out of memory while allocating mailbox command for vPort information.
ACTION: No action required.
2018 REG_VFI mbxStatus error x<status> HBA state x<Portstate>
Mailbox command returned error.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
0306 CONFIG_LINK mbxStatus error x<Status> HBA state x<Portstate>
Mailbox command returned error.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
2017 REG_FCFI mbxStatus error x<Status> HBA state x<Portstate>
Mailbox command for registering FCF returned error.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
2013 Could not manually add FCF record 0, status <Status>
1313 Link Down UNEXP WWPN Event x<EventTag> received Data: x<FC EventTag> x<Portstate> x<Flags>
Unexpected WWPN during Read Topology. Link down.
ACTION: Check the connectivity between the fabric nodes.
1308 Link Down Event in loop back mode <eventTag> received Data: <fc_eventTag> <port_state> <fc_flag>
Link down event occurred in loopback mode.
ACTION: No action required.
1309 Link Up Event npiv not supported in loop topology
NPIV is not supported in loop topology.
ACTION: No action required.
3403 Created Static Vport <vport> with port type <port_type> and vport_flag <vport_flag>
The vPort creation for static port failed.
ACTION: No action required.
2553 lpfc_unregister_unused_fcf failed to read FCF record HBA state <port_state>
Failed to read FCF records.
ACTION: No action required.
2550 UNREG_FCFI mbxStatus error <mbxStatus> HBA state <port_state>
The UNREG_FCFI mailbox command failed.
ACTION: No action required.
2551 UNREG_FCFI mbox allocation failed HBA state <port_state>
The allocation for the UNREG_FCFI mailbox command failed.
ACTION: No action required.
2552 Unregister FCFI command failed rc <rc> HBA state <port_state>
The UNREG_FCFI mailbox command failed.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
42
Emulex Drivers for VMware ESXi User Guide
2554 Could not allocate memory for fcf record
The memory allocation to store fcf_record failed.
ACTION: No action required.
2555 UNREG_VFI mbxStatus error <mbxStatus> HBA state <port_state>
The UNREG_VFI mailbox command failed.
ACTION: No action required.
2798 Unreg_vpi failed vpi <vpi> mb status <mbxStatus>
The UNREG_VPI mailbox command failed.
ACTION: No action required.
3274 ScsiNotifyPathStateChangeAsync SAdapter Num <hostNum> TID <nlp_sid>, DID <nlp_DID>.
Notified the VMkernel about the path state change successfully.
ACTION: No action required.
3275 ScsiNotifyPathStateChangeAsync Failed: <rc> SAdapter Num <hostNum> TID <nlp_sid>, DID <nlp_DID>.
Failure in notifying the VMkernel about the path state change.
ACTION: No action required.
3303 Failed to obtain vport vpi
Failed to get a VPI resource for the vPort.
ACTION: No action required.
3278 No SID assigned for port type <port_type> vpi <vpi>
SCSI ID is not assigned for node belongs to this type of vPort.
ACTION: No action required.
0320 CLEAR_LA mbxStatus error <mbxStatus> hba state <port_state>
The driver issued a CLEAR_LA mailbox command to the HBA that failed.
ACTION: This error could indicate a firmware or hardware issue. Report the error to Broadcom Technical Support.
0206 Device Discovery completion error
This indicates that an uncorrectable error was encountered during device discovery after a link-up. FC devices will not be accessible if this
message is displayed.
ACTION: Reboot the system. If this issue persists, report the error to Broadcom Technical Support. Run with verbose mode enabled for
more information.
0203 Devloss timeout on WWPN <wwpn> NPort <nlp_DID> Data: <nlp_flag> <nlp_state> <nlp_rpi>
A remote N_Port that was discovered by the driver disappeared for more than lpfc_devloss_tmo seconds.
ACTION: If the device generating this message is not a target to which the HBA is connected, this error will not affect the data integrity of
the I/O between the HBA and the attached storage and can be ignored.
0200 CONFIG_LINK bad hba state <port_state>
A CONFIG_LINK mailbox command completed and the driver was not in the right state.
ACTION: Software driver error. If this issue persists, report the error to Broadcom Technical Support.
Reboot the system. If this issue persists, report the error to Broadcom Technical Support. Run with verbose mode enabled for more
information.
Broadcom
DRVVM-UG126-100
43
Emulex Drivers for VMware ESXi User Guide
2606 No NPIV Fabric support
The fabric does not support NPIV port.
ACTION: No action required.
2607 Failed to allocate init_vpi mailbox
The adapter failed to allocate the init_vpi mailbox command.
ACTION: No action required.
0260 Register NameServer error: <mbxStatus>
The REG_LOGIN mailbox command has failed for the NameServer.
ACTION: If the issue persists, report the error to Broadcom Technical Support.
0263 Discovery Mailbox error: state: <port_state> : <sparam_mbox> <cfglink_mbox>
Either the driver could not allocate resources or it could not send the sparam_mbox or cfglink_mbox command.
ACTION: Attempt to unload and reload the driver when it is convenient.
2936 Could not find Vport mapped to vpi <vpi>
The VPI to vPort mapping is not found.
ACTION: No action required.
2608 Failed to issue init_vpi mailbox
The driver was unable to send an INIT_VPI mailbox command.
ACTION: No action required.
2609 Init VPI mailbox failed <mbxStatus>
The INIT_VPI mailbox command sent to firmware failed.
ACTION: No action required.
2765 Mailbox command READ_FCF_RECORD failed to retrieve a FCF record
The READ_FCF_RECORD mailbox command failed to provide any FCF record.
ACTION: No action required.
2521 READ_FCF_RECORD mailbox failed with status <shdr_status> add_status <shdr_add_status>
The READ_FCF_RECORD mailbox command sent to firmware is failed.
ACTION: No action required.
3314 Toplogy changed was <fc_topolgy> is <la>
The FC topology of the port changed.
ACTION: No action required.
9733 CT Request to NS failed
Cannot issue NameServer query.
ACTION: Report the error to Broadcom Technical Support.
0273 Unexpected discovery timeout, vport State <port_state>
The discovery process has timed out.
ACTION: Verify that all targets are still visible. If not, report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
44
Emulex Drivers for VMware ESXi User Guide
3298 ScsiNotifyPathStateChangeAsync SAdapter Num <sadapter number> TID <scsi id> DID <fc did>
Path change notification is successful.
ACTION: No action required.
3299 ScsiNotifyPathStateChangeAsync Failed: <return code> SAdapter Num <sadapter number> TID<scsi id>,
DID <fc did>
Path change notification has failed.
ACTION: Report the error to Broadcom Technical Support.
0258 Register Fabric login error: <mailbox status>
The REG_LOGIN for the fabric failed.
ACTION: Check the port connection and the switch configuration.
2568 Config region 23 has bad version
Failure to read Config Region 23 - invalid version.
ACTION: No action required.
2884 Vport array allocation failed
vPort array memory allocation failure.
ACTION: Reload driver or reboot. If issue persists, report the error to Broadcom Technical Support.
3365 Aborting static vport creation link state <link state> port state <port state>
Failure during static vPort creation.
ACTION: Report the error to Broadcom Technical Support.
3517 fail to rescan
Rescan through keyval page failed.
ACTION: Verify that all targets are still visible. If not, report the error to Broadcom Technical Support.
2567 Config region 23 has bad signature
Failure to read configuration region 23 - invalid signature.
ACTION: No action required.
2566 Failed to allocate connection table entry.
Failed to allocate connection table entry.
ACTION: No action required.
2891 Init VFI mailbox failed <mailbox status>
INIT_VFI mailbox failure.
ACTION: Report the error to Broadcom Technical Support.
2893 Failed to issue init_vfi mailbox
Failed to issue INIT_VFI mailbox command.
ACTION: Report the error to Broadcom Technical Support.
2892 Failed to allocate init_vfi mailbox
Failed to allocate INIT_VFI mailbox command.
ACTION: Report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
45
Emulex Drivers for VMware ESXi User Guide
0259 No NPIV Fabric support
Switch does not support NPIV.
ACTION: Check the switch configuration.
2731 Cannot find fabric controller node
Fabric controller ndlp is not present.
ACTION: Report the error to Broadcom Technical Support.
1815 Could not issue unreg_did (default rpis) status <return code>;
UNREG_DID command failure.
ACTION: Report the error to Broadcom Technical Support.
2749 Failed to prepare for unregistering HBA's FCF record: rc=<return code>
Unregister FCF failure.
ACTION: Report the error to Broadcom Technical Support.
2748 Failed to prepare for unregistering HBA's FCF record: rc=<return code>
Unregister FCF failure.
ACTION: Report the error to Broadcom Technical Support.
0228 CLEAR LA timeout
The driver issued a CLEAR_LA that never completed.
ACTION: None
2726 READ_FCF_RECORD Indicates empty FCF table
The driver requested the firmware provide a list of FCF entries to connect to and the firmware responded that the FCF table is empty.
ACTION: Report the error to Broadcom Technical Support.
0222 Initial <FDISC/FLOGI> timeout
The driver sent the initial FLOGI or FDISK to the fabric and never received a response.
ACTION: Check fabric configuration. The driver recovers from this situation and continues with device discovery.
0223 Timeout while waiting for NameServer login
Login request to the NameServer was not acknowledged within R_A_TOV.
ACTION: Check the fabric configuration. The driver recovers from this and continues with device discovery.
0224 NameServer Query timeout Data: <retry count> <max retry count>
Node authentication timeout, node Discovery timeout. A NameServer Query to the fabric or discovery of reported remote N_Ports is not
acknowledged within R_A_TOV.
ACTION: Check the fabric configuration. The driver recovers from this and continues with device discovery.
0227 Node Authentication timeout
The driver has lost track of what N_Ports are being authenticated.
ACTION: No action required.
1800 Could not issue unreg_vpi
Driver attempt to unregister VPI failed.
ACTION: Software driver error. If this issue persists, report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
46
Emulex Drivers for VMware ESXi User Guide
0319 READ_SPARAM mbxStatus error <mailbox status> hba state <hba state>
The driver issued a READ_SPARAM mailbox command to the HBA that failed.
ACTION: This error could indicate a firmware or hardware issue. Report the error to Broadcom Technical Support.
3233 Error while allocating MSIX interrupts fallback to MSI
MSIX interrupt registration fails. Falling back to MSI.
ACTION: No action required.
0528 Mailbox CQ not allocated
The mailbox CQ is not allocated.
ACTION: No action required.
1302 Invalid speed for this board> <cfg link speed>
The driver is reinitializing the link speed to autodetect.
ACTION: No action required.
0233 Nodelist not empty - Pending nodes are...
Driver unloaded or hot plug detected a node still in use.
ACTION: No action required.
2718 Clear Virtual Link Received for VPI <vpi> tag <event_tag>"
A clear virtual link was received from the fabric for this VPI.
ACTION: No action required.
3228 <function> stopped : state <do_work_state>
Worker thread stopped.
ACTION: No action required.
0454 INTX Interrupt Name Properties failed (<status string>)
INTX interrupt name properties set failed.
ACTION: Check the ESX host configuration and memory usage to free up some resources.
0421 MSI-X SP Interrupt register failed (<status string>)
MSI-X interrupt registration failed.
ACTION: Report the error to Broadcom Technical Support.
0465 MSI Interrupt Name Properties failed (<status string>)
Error in MSI interrupt registration path.
ACTION: Report the error to Broadcom Technical Support.
0478 MSIX Interrupt Enable for FCP failed (<status string>)
MSI-X interrupt registration failed.
ACTION: Report the error to Broadcom Technical Support.
0052 FATAL - unsupported SLI4 interface type - <sli interface type>
Unsupported interface type for SLI4 adapter.
ACTION: Report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
47
Emulex Drivers for VMware ESXi User Guide
0499 Failed allocate fast-path FCP CQ (<cqid>)
The completion queue event for the fast path could not be allocated.
ACTION: Check the ESX host configuration and memory usage to free up some resources.
3258 PathClaim thread death pending....
LPFC worker thread is going down.
ACTION: No action required.
3259 PathClaim Thread create in state <pathclaim_state>
LPFC thread create state.
ACTION: No action required.
0432 INTX Interrupt Register failed (<status string>)
INTX interrupt registration failed.
ACTION: Report the error to Broadcom Technical Support.
0541 Failed setup of Receive Queue: rc = <return code>
RQ_CREATE mailbox failure.
ACTION: Report the error to Broadcom Technical Support.
0540 Receive Queue not allocated
Failed to allocate RQ.
ACTION: No action required.
3276 Failed to create scsidone world.
Failed to create scsidone world.
ACTION: Report the error to Broadcom Technical Support.
3277 Failed to create scsidone world
Failed to create scsidone world.
ACTION: Report the error to Broadcom Technical Support.
1262 Failed to allocate dfc host.
Failed to allocate dfc host.
ACTION: Report the error to Broadcom Technical Support.
3143 Port Down: Firmware Update Detected
Firmware update detected.
ACTION: No action required.
3147 Fast-path EQs not allocated
Fast-path EQs not allocated.
ACTION: Check the system configuration and memory usage.
3148 Fast-path FCP CQ array not allocated
Fast-path FCP CQ array not allocated.
ACTION: Check the system configuration and memory usage.
Broadcom
DRVVM-UG126-100
48
Emulex Drivers for VMware ESXi User Guide
3149 Fast-path FCP WQ array not allocated
Fast-path FCP WQ array not allocated.
ACTION: Check the system configuration and memory usage.
2562 Failure to allocate an ELS sgl entry:<index>
Failure to allocate an ELS sgl entry.
ACTION: Report the error to Broadcom Technical Support.
0505 Failed allocate slow-path MQ
Failed allocate slow-path Multi-Queue
ACTION: Check the system configuration and memory usage.
7623 Checking UE recoverable
Checking for unrecoverable error recoverable.
ACTION: No action required.
0395 The mboxq allocation failed
Failed to allocate mailbox.
ACTION: Check the system configuration and memory usage.
3254 ERROR: invalid type <type>
Invalid type EPROM.
ACTION: Report the error to Broadcom Technical Support.
2598 Adapter Link is disabled
Adapter link 2598 is disabled.
ACTION: Report the error to Broadcom Technical Support.
2599 Adapter failed to issue DOWN_LINK mbox command rc <return>
Adapter failed to issue DOWN_LINK mailbox command.
ACTION: Report the error to Broadcom Technical Support.
4673 CGN Event empty object
Congestion management event empty object
ACTION:
9032 Destroying vport <vport> refcnt <refcount>
Destroying virtual port (NPIV).
ACTION: No action required.
0397 The mbuf allocation failed
The mbuf allocation failed.
ACTION: Check the system configuration and memory usage.
9036 Free vport with non-zero refcount <count>
Freeing vPort with non-zero refcount.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
49
Emulex Drivers for VMware ESXi User Guide
0420 MSI-X alloc cookie <status>
MSI-X allocation failed for LPe12000-series adapter.
ACTION: Check the ESX configuration, if issue is still seen contact VMware or Broadcom support team.
9035 Destroying Physical port <vport> refcnt <refcount>
Destroying physical port.
ACTION: No action required.
3296 LPFC_SLI_EVENT_TYPE_MISCONFIGURED event: Invalid link <port no>
Invalid link number for LPFC_SLI_EVENT_TYPE_MISCONFIGURED event.
ACTION: Report the error to Broadcom Technical Support.
4670 CGN RD OBJ returns no data
Congestion management read object returns no data.
ACTION: Report the error to Broadcom Technical Support.
3163 ELS xri-sgl count unchanged: <els_xri_cnt>
ELS xri-sgl count unchanged.
ACTION: No action required.
1421 Failed to set up hba
Failed to set up HBA.
ACTION: Report the error to Broadcom Technical Support.
4672 CgnParms write err (<ret>). Disable E2E mgmt
Congestion management write objecterror, disable E2E mgmt.
ACTION: Report the error to Broadcom Technical Support.
1422 Unrecoverable Error Detected during POST uerr_lo_reg=<uerrlo_reg> uerr_hi_reg=<uerrhi_reg>,
ue_mask_lo_reg=<ue_mask_lo>, ue_mask_hi_reg=<ue_mask_hi>
Unrecoverable error detected during POST.
ACTION: Report the error to Broadcom Technical Support.
0321 Interrupt cfg mode set to <cfg_mode>
Interrupt cfg mode set to given mode in the cfg_mode
ACTION: No action required.
2887 Reset Needed: Attempting Port Recovery...
Driver trying to reset by attempting port recovery.
ACTION: No action required.
0358 Interrupt cfg mode set to (<cfg_mode>) vectors (<vector_count>)
Interrupt cfg mode set with number of vectors.
ACTION: No action required.
0501 Failed allocate slow-path ELS CQ
Failed to allocate slow-path for ELS CQ.
ACTION: Check the ESX configuration, if issue is still seen contact VMware or Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
50
Emulex Drivers for VMware ESXi User Guide
2563 Failure to allocate an ELS mbuf <index>
Failed to allocate an ELS mbuf.
ACTION: Check the system configuration and memory usage.
2889 Port Overtemperature event, taking port offline Data: <err1> <err2>"
Temperature of the adapter is very high.
ACTION: Check the cooling mechanism of server. Ensure that the server fans are not blocked. Shut down the server if the airflow is
restricted. Contact Broadcom Technical Support.
3360 LUN queue depth changed from <prev> to <new>
The LUN queue depth has changed.
ACTION: No action required.
3361 HBA queue detph changed from <prev> to <new>
The HBA queue depth has changed.
ACTION: No action required.
0507: Failed allocate receive DRQ
Failed to allocate receive DRQ.
ACTION: No action required.
0506 Failed allocate receive HRQ
The driver failed to allocate receive HRQ
ACTION: No action required.
0468 MSI Interrupt Enable failed
The driver failed to start the interrupt.
ACTION: Unload and reload the driver.
<fail code>
0463 MSI-X wanted <n> vectors, got <m>
The driver failed to get required MSI-X interrupt vectors.
ACTION: No action required.
0503: Failed allocate fast-path FCP WQ <wq_idx>
Failed to allocate fast-path FCP.
ACTION: No action required.
0467 MSI Interrupt Register failed
The driver failed to register the interrupt.
ACTION: Unload and reload the driver.
<fail code>
0464 MSI alloc cookie failed <fail code>
The driver failed to allocate interrupt cookie.
ACTION: Unload and reload the driver.
0426 Failed to enable interrupt
The driver failed to enable the interrupt.
ACTION: Unload and reload the driver
Broadcom
DRVVM-UG126-100
51
Emulex Drivers for VMware ESXi User Guide
2813 Mgmt I/O is Blocked <value> - mbox cmd <value> still active.
The HBA management interface is marked as blocked in preparation for an online or offline state transition. All user space access to the
HBA through the libdfc interface will be blocked.
ACTION: No action required. Notification of a run-state change only.
0351: Config MSI mailbox command failed, mbxCmd <cmd>, mbxStatus <Status>
The mailbox command sent to the firmware to configure the adapter to use MSI-X has failed.
ACTION: Ensure that the hardware platform supports MSI-X.
4671 CgnParms read err (<return code>) Disable E2E mgmt
Unable to read congestion firmware parameters from the adapter.
ACTION: Report the error to Broadcom Technical Support.
0484 MSI-X Interrupt Enable failed <err_code>
The driver failed to start the interrupt.
ACTION: Unload and reload the driver.
0522 Fast-path EQ <eq_idx> not allocated
The fast-path EQ is not allocated.
ACTION: No action required.
3176: Misconfigured Physical Port - Port Name <value>
The driver has detected an unknown firmware name.
ACTION: Contact Broadcom Technical Support.
0474 Unable to allocate memory for issuing MBOX_CONFIG_MSI command
Mailbox memory pool allocation error.
ACTION: No action required.
2899 The mbuf allocation failed
The mbuf allocation failed.
ACTION: No action required.
2898 The lpfc_dmabuf allocation failed);
The lpfc_dmabuf allocation failed.
ACTION: No action required.
0473 MSI Interrupt Enable failed
The driver failed to start the interrupt.
ACTION: Unload and reload the driver.
<fail code>
0472 MSI Interrupt Register failed
The driver failed to register the interrupt.
ACTION: Unload and reload the driver.
<fail code>
2895 Non FC link Event detected.<value>
Non FC link event detected.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
52
Emulex Drivers for VMware ESXi User Guide
2894 SLI_INTF reg contents invalid sli_intf reg <value>
SLI_INTF reg contents invalid sli_intf reg <value>
ACTION: No action required.
2897 The mboxq allocation failed
The driver could not allocate mbox queue.
ACTION: No action required.
0479 Deferred Adapter Hardware Error Data: <host_status> <status1> <status2>
An adapter hardware error was sent to the driver.
ACTION: Perform a dump using hbacmd.
2890 Port not ready, port status reg <value> error 1=<val>
Port error detected during port reset.
ACTION: Reboot the server. Contact Broadcom Technical Support.
error 2=<val>
2576 Failed allocate memory for fast-path EQ record array
Failed to allocate memory for the fast-path EQ record array.
ACTION: No action required.
0290 The SLI4 DCBX asynchronous event is not handled yet
The SLI-4 DCBX asynchronous event is not handled yet.
ACTION: No action required.
3144 Port Down: Debug Dump
Port Down: Debug Dump
ACTION: Reboot the server. Contact Broadcom Technical Support.
2012: Mailbox failed , mbxCmd <mbx_cmd> READ_CONFIG, mbxStatus <mbx status>
The READ_CONFIG mailbox command failed.
ACTION: No action required.
0408 Failed to create path claim world.
The driver failed to create new thread.
ACTION: Unload and reload the driver.
2560 Failed to allocate xri for scsi buffer
Initialization could not allocate memory to hold the XRIs.
ACTION: No action required.
3145 Port Down: Provisioning
The driver failed to create new thread.
ACTION: Unload and reload the driver.
0396 The lpfc_dmabuf allocation failed);
The asynchronous link event handler could not allocate a mailbox command to issue the READ_LA mailbox command.
ACTION: Unload and reload the driver.
Broadcom
DRVVM-UG126-100
53
Emulex Drivers for VMware ESXi User Guide
0498 Adapter failed to init, mbxCmd <mbx_cmd> INIT_LINK, mbxStatus <mbx_status>
The adapter failed to initialize. The INIT_LINK command failed.
ACTION: Ensure that the adapter firmware is current. Unload and reload the driver.
0391 Error during rpi post operation
The driver while trying to post pages to the firmware to keep target login information encountered a failure.
ACTION: Unload and reload the driver.
0493: SLI_CONFIG_SPECIAL mailbox failed with status<rc>
Mailbox command failed.
ACTION: Ensure that the adapter firmware is current. Unload and reload the driver.
0492 Unable to allocate memory for issuing SLI_CONFIG_SPECIAL mailbox command
Mailbox memory pool allocation error.
ACTION: No action required.
0491 Adapter Link is disabled.
Adapter link is disabled by administrator
ACTION: Check the cables and enable the link using application.
0398 Unknown link fault code: <code>
The attempt to read the link attention register returned an unknown value.
ACTION: Check the cables and reload the driver.
0399 Invalid link attention type: <evt_type>
The READ_LA mailbox command returned an invalid link type.
ACTION: Check the cables and reload the driver. Reset the HBA.
0495: SLI_FUNCTION_RESET mailbox failed with status <shdr_status> add_status <shdr_add_status>, mbx
status <rc>.
Mailbox command failed.
ACTION: Reset the HBA.
0494 Unable to allocate memory for issuing SLI_FUNCTION_RESET mailbox command
Mailbox memory pool allocation error.
ACTION: No action required.
2578 Failed allocate memory for fast-path WQ record array
Failed to allocate memory for the fast-path EQ record array.
ACTION: No action required.
9182 DMA Buffer size check failed: Used <idx> Allocated <size>
The DMA buffer size is not as per expected value.
ACTION: Reload the driver. Reset the HBA.
0504 Failed allocate slow-path ELS WQ
Failed to allocate memory for the slow-path ELS EQ record array.
ACTION: Reload the driver.
Broadcom
DRVVM-UG126-100
54
Emulex Drivers for VMware ESXi User Guide
0796 LUN Reset on Target <FCID> <LUN> <State> <status>
A LUN reset was issued by SCSI stack to the specified target.
ACTION: No action required.
0525: Failed to setup FOF EQ lock <error code>
The driver failed to setup the FOF event queue lock.
ACTION: Unload and reload the driver.
0401 Link fault code: <value>
The link went into fault mode.
ACTION: Check the cables and reload the driver.
3231 Error while allocating MSI interrupt fallback to INTx
The driver failed to allocate MSI interrupts, so falling back to INTx.
ACTION: No action required.
0406: Adapter maximum temperature exceeded <temperature>, taking this port offline
The driver has received an error for the HBA indicating that the maximum allowable temperature has been exceeded.
ACTION: Ensure that the server fans are not blocked. Shut down the server if the airflow is restricted.
0407 Target Reset on Target <FCID> <LUN> <State> <status>
A target reset was issued by SCSI stack to the specified target.
ACTION: No action required.
4000 Failed to query PCI IO resources <status> - Disable DPP.
The driver fails to query PCI IO resources.
ACTION: Disable DPP feature and reload the driver.
4001 Failed to reserve DPP resource <status> - Disable DPP
The driver fails to reserver DPP resources.
ACTION: Disable DPP feature and reload the driver.
4002 Failed to map DPP regsiters <status> - Disable DPP
The driver fails to map DPP registers.
ACTION: Disable the DPP feature and reload the driver.
3344 HBA queue detph changed from <prev> to <new>
The HBA queue depth has changed.
ACTION: No action required.
2747 Issue FCF scan read FCF mailbox command failed <error code>
The firmware failed the FCF mailbox command.
ACTION: Unload and reload the driver.
0461 INTX Interrupt Enable failed <fail code>
The driver failed to enable the interrupt.
ACTION: Unload and reload the driver.
Broadcom
DRVVM-UG126-100
55
Emulex Drivers for VMware ESXi User Guide
0714 SCSI layer issued Bus Reset Data <status>
The SCSI layer is requesting the driver to abort all I/Os to all targets on this HBA.
ACTION: Check the state of the targets in question.
0524: Failed to setup EQ lock <error code>
The driver failed to setup the event queue lock.
ACTION: Unload and reload the driver.
0022 FATAL - unsupported SLI4 interface type - <if_value>
The adapter is not supported by the driver.
ACTION: Update to latest firmware or replace the adapter.
2877: FCP XRI exchange busy wait time: <value> seconds
An FCP exchange cannot be released -- no port completion. The driver is waiting.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3234 Error while allocating MSIX interrupts fallback to MSI
The driver failed to allocate MSI-X interrupts, so falling back to MSI.
ACTION: No action required.
0431 Failed to enable interrupt.
The driver failed to start the interrupt.
ACTION: Unload and reload the driver.
2644 Failed to alloc memory for RX Monitor Buffer
Failure to allocate memory for RX monitor table.
ACTION: No action required.
2645 Failed to alloc memory for RX Monitor Buffer
Failure to allocate memory for RX monitor table.
ACTION: No action required.
0485 MSI alloc cookie failed <fail code>
The driver failed to allocate interrupt cookie.
ACTION: Unload and reload the driver.
1430 Failed to initialize sgl list.
Failed to initialize SQL list.
ACTION: No action required.
0403 Failed to create path claim world.
The driver failed to create new thread.
ACTION: Unload and reload the driver.
0486 MSI-X Interrupt Register failed <fail code>
The driver failed to register the interrupt.
ACTION: Report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
56
Emulex Drivers for VMware ESXi User Guide
0427: Cannot re-enable interrupt after slot reset
The driver was not able to enable the interrupt after an adapter reset.
ACTION: Unload and reload the driver.
0434 MIS-X Interrupt Name Properties failed <vmkStat>
MSIx initialization failed.
ACTION: Unload and reload the driver. If the issue persists, report the error to Broadcom Technical Support.
0527: Failed setup of fast-path FCP NVMe WQ/CQ <cqidx>, rc = <ret_val>
The fast-path FCP completion queue setup failed.
ACTION: The driver fails to load. Contact Broadcom Technical Support.
0487 PCI enable MSI-X failed <vmkStat>
Enabling MSIx failed.
ACTION: Unload and reload the driver. If the issue persists, report the error to Broadcom Technical Support.
3359 HBA queue depth changed from <value> to <value>
Updated HBA queue depth value.
ACTION: No action required.
0526: Fast-path FCP CQ <fcp_cqidx> not allocated
The fast-path FCP is not allocated.
ACTION: The driver fails to load. Contact Broadcom Technical Support.
0411 Failed to alloc memory for Congestion Info
Failed to allocate congestion data buffer.
ACTION: The driver fails to load. Contact Broadcom Technical Support.
1804: Invalid asynchronous event code: <evt code>
The asynchronous event code that the firmware passed to the driver is invalid.
ACTION: No action required.
4669 FW cgn parm buf wrong magic <magic_num> version <version>
Invalid congestion buffer signature from firmware.
ACTION: No action required. If the issue persists, report the error to Broadcom Technical Support.
3119 Failed to get SystemVer <vmkStat>
Failed to get the operating system version information.
ACTION: No action required.
3118 Failed to close CfgParm Handle <vmkStat>
Failed to close config param handle.
ACTION: No action required.
3117 Failed to open CfgParm Handle. <vmkStat>
Failed to open config param handle.
ACTION: No action required
Broadcom
DRVVM-UG126-100
57
Emulex Drivers for VMware ESXi User Guide
1201: Failed to allocate dfc_host
The driver failed to allocate a DFC host and bind it to the management stack.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
4667 Error reading Cgn Params
Unable to read congestion firmware parameters from adapter.
ACTION: No action required. If the issue persists, report the error to Broadcom Technical Support.
1431: Invalid HBA PCI-device group: <dev_grp>
An invalid adapter PCI-device group was detected.
ACTION: No action required.
8912 Async FC Trunking Event - Speed Logical speed: port0 <Link_status> port1 <link_status> port2
<link_status> port3 <link_status>
Trunked port link status update.
ACTION: No action required
8913 trunk error:<trunk_error> seen on port0: <Link_Status> port1:<Link_Status> port2:<Link_Status>
port3:<Link_Status> UNDEFINED. update driver
Trunk port setting error.
ACTION: If the issue persists, report the error to Broadcom Technical Support.
0150 Attempting reset to recover from UE
Driver in recovery phase from UE.
ACTION: No action required.
3190 Over Temperature: <Value> Celsius- Port Name <Value>
Display temperature above the threshold value.
ACTION: No action required. If the issue persists, report the error to Broadcom Technical Support.
0314 Failed to start lpfc_do_work World
Failed to create the world.
ACTION: The driver fails to load. Contact Broadcom Technical Support..
0529: Failed setup of slow-path mailbox CQ: rc = <value>
The driver failed to set up the completion queue. A failure code is reported.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
0475 Not configured for supporting MSI-X cfg_use_msi: <cfg_use_msi>.
The lpfc_use_msi module parameter should have been set to 2.
ACTION: Set module parameter lpfc_use_msi=2.
1814 Mbox <u.mb.mbxCommand> failed, no vport
The vPort field of this mailbox command was not completed.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
2527: Failed to allocate non-embedded SGE array.
The driver failed to allocate the non-embedded scatter/gather entry array.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
58
Emulex Drivers for VMware ESXi User Guide
2929: Resource Extent Opcode <value> is unsupported
Unsupported event code.
ACTION: No action required.
2605: lpfc_dump_static_vport: memory allocation failed
Memory allocation failed.
ACTION: Try closing other applications to free some memory. If this issue persists, report the error to Broadcom Technical Support.
0291: Allocated DMA memory size <alloc_len> is less than the requested DMA memorysize <req_len>
The asynchronous DCBX events are not handled in the driver.
ACTION: Check the switch configuration.
3569 dump type 3 page 0xA0 allocation failed
Memory allocation failure.
ACTION: Try closing other applications to free some memory. If this issue persists, report the error to Broadcom Technical Support.
0301 READ_SPARAM: no buffers
The driver attempted to issue a READ_SPARAM mailbox command to the adapter, but there were no buffers available.
ACTION: Try closing other applications to free some memory.If this issue persists, report the error to Broadcom Technical Support.
3371 Alloc failure from Slab <Slab_ID> Caller <func:line> cur cnt <Curr_Slab_Cnt> Max <Max_Slab_Cnt>
Slab allocation failure.
ACTION: Try closing other applications to free some memory. If this issue persists, report the error to Broadcom Technical Support.
3309 Alloc failure. Caller <func> <line>
Heap allocation failure.
ACTION: Try closing other applications to free some memory. If this issue persists, report the error to Broadcom Technical Support.
3480 Failed to Create Slab Status <vmkStat> <func> <line>
Slab creation failed. The driver fails to load
ACTION: Contact Broadcom Technical Support.
3310 Alloc failure. Caller <func> <line>
Aligned Heap allocation failure.
ACTION: Try closing other applications to free some memory. If this issue persists, report the error to Broadcom Technical Support.
3207 <func_name> DMAMapSg failed addr <virt_addr> size <size> rc <ret_val> string <err_msg>
DMA mapping of SG array to I/O address failed.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3206 <func_name> DMAMapSg failed addr <virt_addr> size <size> rc <ret_val> string <err_msg>
DMA mapping of SG array to I/O address for SCSI buffer failed.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3204 <func_name> DMAMapSg failed addr <virt_addr> size <size> rc <ret_val> string <err_msg>
DMA mapping of SG array to I/O address for ELS buffer failed.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
59
Emulex Drivers for VMware ESXi User Guide
3202 <func_name> DMAMapSg failed addr <virt_addr> size <size> rc <ret_val> string <err_msg>
DMA mapping of SG array to I/O address for MBUF buffer failed.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3201 No extended DMAMapSg err data
DMA map SG error.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3200 No IO Space Err. MaxMappable <error_info>
Not enough I/O address space available to map elements.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3374 Slab Obj for ID <slab_id> Alloc <func:line> Free <func:line>
Slab memory to be freed not found.
ACTION: No action required.
3209 <func_name> DMAMapSg failed addr <virt_addr> size <size> rc <ret_val> string <err_msg>
DMA mapping of SG array to I/O address for data receive buffer failed.
ACTION: No action required.
3208 <func_name> DMAMapSg failed addr <virt_addr> size <size> rc <ret_val> string <err_msg>
DMA mapping of SG array to I/O address for header receive buffer failed.
ACTION: No action required.
3197 AddrStraddle Err. Bdry <error_info> ElemNum <bad_element>
Could not map SG array to fit within the sgMaxEntries constraint with the sgElemStraddle constraint.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3196 ElemSizeMulti Err. Size <error_info> ElemNum <bad_element>
Could not map SG array to fit within the sgMaxEntries constraint with the sgElemMult constraint.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3195 Max Size Err-> Max %d ElemNum %d, err->info.elemMaxSize.sgElemMaxSize, err>info.elemMaxSize.badElem
Could not map SG array to fit within sgMaxEntries constraint with the sgElemMaxSize constraint.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3194 Too Many Entries count <sg_entry_count>
There were too many SG array elements in the SG array and the mapping code was unable to coalesce the array to fit.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3199 Address Alignment Err. Align <alignment> ElemNum <element>
One or more SG array elements are not aligned properly.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3198 Address Err. Mask <addr_mask> ElemNum <element>
One or more SG array elements do not meet the address mask of the DMA engine.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
60
Emulex Drivers for VMware ESXi User Guide
3271 OAS slab empty
OAS slab allocation failed.
ACTION: If this issue persists, report the error to Broadcom Technical Support.
2946: SLI_CONFIG(hbd) rd, ext_buf_cnt(<value>) out of range(<max_value>)
Host buffer descriptor count out of range.
ACTION: If this issue persists, report the error to Broadcom Technical Support.
2945: SLI_CONFIG(mse) rd, ext_buf_cnt(<value>) out of range(<value>)
SLI_CONFIG read mailbox failed.
ACTION: No action required.
3383 OAS detected unsupported string version <version>
Unsupported OAS version.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3381 No OAS version pointer from caller
No OAS version passed.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
1944: ENOMEM kernel memory resource unavailable
The driver failed to allocate a kernel buffer for a timed-out I/O request.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3389 OAS parser error - <rules> rules found with a partial rule length of <len>
Error is parsing OAS rule.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3070: lpc_clr_ndlps_pri: fcp_priority sz = <value>
Clear FCP priority for the target.
ACTION: No action required.
3150: No privilege to perform the requested access: <requested_action>
The driver lacks the necessary privileges for the requested action.
ACTION: Contact Broadcom Technical Support.
2954: SLI_CONFIG(hbd) wr to interface type:<value>
Write to interface type.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3382 OAS parser error - <rules> rules found with a partial rule length of <len>
Error is parsing OAS rule.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
2950: Failed SLI_CONFIG(hbd) rd (<value>)
Mailbox issue failed.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
61
Emulex Drivers for VMware ESXi User Guide
3050 SLI_CONFIG(hbd) wr,ext_buf_cnt <value> out of range <value>
Host buffer descriptor count out of range.
ACTION: If this issue persists, report the error to Broadcom Technical Support.
3153: Fail to perform the requested access: <value>
The driver failed to execute the requested management action.
ACTION: Contact Broadcom Technical Support.
3377 OAS slab empty
OAS slab memory allocation failure.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3444 Failed SLI_CONFIG(hbd) wr <value>
Write to interface type.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
3032 SLI_CONFIG(hbd) rd to interface type: <value>
Read to interface type.
ACTION: This is a software error. If this issue persists, report the error to Broadcom Technical Support.
1209: C_CT Request error Data: <resp_buff_flag> <data_size>
IOCTL common transport response error -- the driver is failing the IOCTL request.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
1208: C_CT Request error Data: <resp_buff_flag> <data_size>
IOCTL common transport response error -- the driver is failing the IOCTL request.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
1952: ENOMEM DMA resource not available
The driver failed to get the DMA buffers needed for a loopback test.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
1928: Exec format error
There was no dfchba instance available.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3142: Failed loopback test issue iocb: iocb_stat: <ret_val>
Loopback test failed.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3412: Restart FW Logging
RAS buffer memory not allocated.
ACTION: Restart RAS firmware-logging support.
1927 VMK_NO_MEMORY kernel memory resource unavailable
The driver failed to allocate a kernel memory.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
62
Emulex Drivers for VMware ESXi User Guide
1929 Exec format error
There was no dfchba instance available for an IOCTL loopback XRI read -- dropping.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3069: Clearing FCP rules
Clear the FCP priority rules.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3172 Attempted to add already registered entry <uuid> with vmid: <cs_ctl>
Attempted to re-register a VMID entry.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3125: Not receiving unsolicited event <ret_val>
Mgmt Loopback Test. IOCB timed out.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3071: no memory for priority rules
Memory allocation for FCP priority rules setting failed.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
1957 VMK_NO_PERMISSION Illegal BDE count <rcv_buf_cnt>
The driver received too many receive buffers for a loopback operation.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
1949 VMK_NOT_EXEC NULL param passed to function
The driver tried to post a receive buffer, but no receive buffers are available.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
1951 VMK_NO_MEMORY MBUF resources
The driver failed to get the memory buffer needed for a loopback test.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
1950 VMK_NO_MEMORY IOCB resource not available
The driver could not allocate the IOCBs needed to post loopback receive buffers.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
1935 Loopback did not receive data
The driver ran a loopback test but did not receive a response.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
1934 VMK_NO_MEMORY DMA coherent resource unavailale
The driver failed to allocate a DMA buffer for an IOCTL request.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3171 Attempted to delete unregistered entry <uuid> with vmid: <vmid>
Unregistered VMID entry tried to be deleted.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
63
Emulex Drivers for VMware ESXi User Guide
3141 Loopback mode:<link_flags> not supported
Loopback mode passed by user not supported.
ACTION: Check the loopback mode passed. If this issue persists, report the error to Broadcom Technical Support.
3010: Run link diag test mailbox failed with mbx_status <value> status <value>, add_status <value>
Link diagnostics test failed.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
3170 Update process failed for entry[<entry>] with status: <status>
VMID update process failed for entry.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
1936 VMK_NO_MEMORY Kernel resource unavailale);
The driver failed to allocate a DMA buffer during a loopback test.
ACTION: This is a software driver error. If this issue persists, report the error to Broadcom Technical Support.
0362 Unsupported MQ count. (<entry count>)
Unsupported MQ entry count.
ACTION: No action required.
3023 Allocated DMA memory size (<alloclen>) is less than requested (<reqlen>)
Allocated mailbox command memory size is less than the requested size.
ACTION: Report the error to Broadcom Technical Support.
(<vpi>):0311 Mailbox command <mailbox command code> cannot issue Data: <sli flag> <flag>
Cannot issue mailbox command because link is in error state.
ACTION: Report the error to Broadcom Technical Support.
3321 Recovered mailbox <mailbox command code>
Mailbox command recovered.
ACTION: No action required.
2365 Failed to get SG alloc address status <status string>
Memory allocation failure during MDS diagnostics.
ACTION: Report the error to Broadcom Technical Support.
0366 Not a valid fast-path completion event: majorcode=<event type>, minorcode=<additional info>
Not a CQ completion.
ACTION: No action required.
2620 Config region 23 has bad version
Failure to read Config Region 23 - invalid version.
ACTION: No action required.
1832 No pending MBOX command to handle
No outstanding mailbox command to process.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
64
Emulex Drivers for VMware ESXi User Guide
2746 Requesting for FCF rediscovery failed status <status> add_status <additional status>
Rediscover FCF mailbox command failed.
ACTION: Report the error to Broadcom Technical Support.
2523 Allocated DMA memory size (<alloclen>) is less than the requested DMA memory size (<reqlen>)
Allocated mailbox command memory size is less than the requested size.
ACTION: Report the error to Broadcom Technical Support.
3252 WQ[<workqueue id>] doorbell offset not supported: <offset>
Unsupported WQ doorbell offset.
ACTION: Report the error to Broadcom Technical Support.
(<vpi>):2529 Mailbox command <mailbox command code> cannot issue Data: <sli flag> <flag>
Cannot issue mailbox because another mailbox command is already active.
ACTION: Report these errors to Broadcom Technical Support.
(<vpi>):2528 Mailbox command <mailbox command code> cannot issue Data: <sli flag> <flag>"
Cannot issue mailbox because mailbox interrupt is disabled.
ACTION: Report the error to Broadcom Technical Support.
2009 Failed to allocate mbox for ADD_FCF cmd
Cannot allocate memory mailbox command.
ACTION: Report the error to Broadcom Technical Support.
2536 Unsupported RQ count. (<entry_count>)
Unsupported RQ entry count.
ACTION: No action required.
0144 Not a valid WCQE code: <wcqe code>
Invalid WCQE code.
ACTION: Report the error to Broadcom Technical Support.
2014 Invalid command <iocb command code>
Invalid IOCB.
ACTION: Report these errors to Broadcom Technical Support.
(<vpi>):0304 Stray Mailbox Interrupt mbxCommand <mailbox command code> mbxStatus <mailbox status>
Stray mailbox interrupt.
ACTION: Report the error to Broadcom Technical Support.
0303 Ring <ring numbber> handler: portRspPut <put index> is bigger than rsp ring <max index>
Ring put index is greater than size.
ACTION: Report these errors to Broadcom Technical Support.
2010 Resume RPI Mailbox failed status <return code>, mbxStatus <mailbox status>
RESUME_RPI mailbox command failure.
ACTION: Report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
65
Emulex Drivers for VMware ESXi User Guide
2509 RQ_DESTROY mailbox failed with status <mailbox status> add_status <additional status>, mbx status
<return code>
RQ_DESTROY mailbox command failure.
ACTION: Report the error to Broadcom Technical Support.
2919 Failed to release resource extents for type <extent type> - Status <mailbox status> Add'l Status
<additional status>. Resource memory not released.
Deallocation resource extent mailbox command failure.
ACTION: Report the error to Broadcom Technical Support.
2707 Ring <els ring number> handler: Failed to allocate iocb Rctl <fc header rctl> Type <fc header
type> received
IOCB is not available to process unsolicited requests.
ACTION: Report these errors to Broadcom Technical Support.
2508 WQ_DESTROY mailbox failed with status <mailbox status> add_status <additional status>, mbx status
<return code>
WQ_DESTROY mailbox command failure.
ACTION: Report the error to Broadcom Technical Support.
2856 Config Port Security Crypto Error: <error code>
Configuration port security crypto error.
ACTION: Report the error to Broadcom Technical Support.
8029 PCIe Read from <address> failed after <retry count> attempts.
PCIe read failure.
ACTION: Report these errors to Broadcom Technical Support.
2619 Config region 23 has bad signature
Failure to read Config Region 23 -- invalid signature.
ACTION: Report these errors to Broadcom Technical Support.
0438 Adapter failed to init, chipset, status reg <status register value>, FW Data: A8 <UERR_MASK_LO>
AC <UERR_MASK_HI>
Adapter initialization failed.
ACTION: Report the error to Broadcom Technical Support.
2558 ADD_FCF_RECORD mailbox failed with status <mailbox status> add_status <additional status>
ADD_FCF_RECORD mailbox failed.
ACTION: Report the error to Broadcom Technical Support.
3037 Allocated DMA memory size (<alloclen>) is less than requested (<reqlen>)
Allocated mailbox command memory size is less than requested size.
ACTION: Report the error to Broadcom Technical Support.
3030 Delete Object mailbox failed with status <mailbox status> add_status <additional status>, mbx
status <return code>
DELETE_OBJECT mailbox command failed.
ACTION: Report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
66
Emulex Drivers for VMware ESXi User Guide
1820 Unable to select SLI-3. Not supported by adapter
Adapter initialization failed.
ACTION: Report the error to Broadcom Technical Support.
0437 Adapter failed to init, chipset, status reg <status register value>, FW Data: A8 <UERR_MASK_LO>
AC <UERR_MASK_HI>
Adapter initialization failed.
ACTION: Report the error to Broadcom Technical Support.
0436 Adapter failed to init, timeout, status reg <status register value>, FW Data: A8 <UERR_MASK_LO>
AC <UERR_MASK_HI>
Adapter initialization failed.
ACTION: Report the error to Broadcom Technical Support.
0602 Failed to allocate CQ_EVENT entry
CQE event pool is empty.
ACTION: Report the error to Broadcom Technical Support.
1419 Invalid HBA PCI-device group: <pci device group id>
Invalid PCI device group.
ACTION: Report the error to Broadcom Technical Support.
0338 IOCB wait timeout error - no wake response Data <timeout value>
IOCB timed out waiting for a response.
ACTION: Report the error to Broadcom Technical Support.
2000 Failed to allocate mbox for READ_FCF cmd
Memory allocation failure.
ACTION: Report the error to Broadcom Technical Support.
0334 Unknown IOCB command Data: <type> <command> <status> <iotag> <ulpcontext>
Unknown IOCB command.
ACTION: Report the error to Broadcom Technical Support.
0335 Unknown IOCB command Data: <command> <status> <iotag> <context>
Unknown IOCB command.
ACTION: Report the error to Broadcom Technical Support.
9148 OAS completion queue does not exist
OAS completion queue does not exist.
ACTION: Report the error to Broadcom Technical Support.
9149 Miss-matched fast-path compl queue id: eqcqid=%d, fcpcqid=%d
CQ ID mismatch in FOF EQE handler.
ACTION: Report the error to Broadcom Technical Support.
3164 Abort failed: No iocbqs: Data: <xri> <iotag> <ulpcontext> <command>
IOCB is not available to send abort.
ACTION: Report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
67
Emulex Drivers for VMware ESXi User Guide
3300 Ring <ring number> issue: portCmdGet <get index> is bigger than cmd ring <end of ring>
Ring get index is greater than size.
ACTION: Report the error to Broadcom Technical Support.
0326 Not a valid fast-path completion event: majorcode=<event type>, minorcode=<additional info>
Not a CQ completion.
ACTION: Report the error to Broadcom Technical Support.
3471 : RAS FW-Logging Enable Failed :<status string>
RAS FW logging is not enabled.
ACTION: No action required.
(<vpi>) 0323 Unknown Mailbox command <command> (<subsystem>/<opcode>) Cmpl
Unknown mailbox command.
ACTION: Report the error to Broadcom Technical Support.
2983 Allocated DMA memory size (<alloclen>) is less than the requested DMA memory size (<reqlen>)
Allocated mailbox command memory size is less than requested size.
ACTION: Report the error to Broadcom Technical Support.
2982 Allocated DMA memory size (<alloclen>) is less than the requested DMA memory size (<reqlen>)
Allocated mailbox command memory size is less than the requested size.
ACTION: Report the error to Broadcom Technical Support.
0285 Allocated DMA memory size (<alloclen>) is less than the requested DMA memory size (<reqlen>)
Allocated mailbox command memory size is less than requested size.
ACTION: Report the error to Broadcom Technical Support.
3479 Invalid provisioning of rpi:<max_rpi>
Maximum RPI count is zero or negative.
ACTION: Report the error to Broadcom Technical Support.
3573 RAS Mailbox failed. status <rc> mbxStatus : x<lpfc_mqe_status>
The mailbox to initialize firmware logging in host has failed.
ACTION: No action required.
2984 Failed to read allocated resources for type <response> - Status 0x<status>
The mailbox to get allocated extent resource has failed.
ACTION: No action required.
3025 Write Object mailbox failed with status x<shdr_status> add_status x<shdr_add_status>, mbx status
x<rc>
The write object mailbox command has failed.
ACTION: No action required.
0445 Firmware initialization failed
The SLI3 HBA initialization has failed.
ACTION: Check if port reset brings back to normal state. If issue persists, contact Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
68
Emulex Drivers for VMware ESXi User Guide
0446 Adapter failed to init <rc>, mbxCmd x<mbxCommand> CFG_RING, mbxStatus x<mbxStatus>, ring <i>
The configuration ring mailbox has failed.
ACTION: Check if port reset brings back to normal state. If issue persists, contact Broadcom Technical Support.
1400 Failed to update xri-sgl size and mapping: <rc>
Failed to initialize SGL list during initialization.
ACTION: No action required.
0442 Adapter failed to init, mbxCmd x<mbxCommand> CONFIG_PORT, mbxStatus x<mbxStatus>
Adapter initialization failed when issuing a CONFIG_PORT mailbox command.
ACTION: This error could indicate a hardware or firmware issue. If this issue persists, report the error to Broadcom Technical Support.
0443 Adapter did not grant BlockGuard
Adapter does not support the BlockGuard feature.
ACTION: No action required.
2600 failed to allocate mailbox memory
Failed to allocate memory for configure region 23 mailbox command.
ACTION: No action required.
2763 Failed to allocate mbox for READ_FCF cmd
Memory for the READ_FCF command is not allocated.
ACTION: Report the error to Broadcom Technical Support..
2762 FCF <fcf_index> reached driver's book keeping dimension: <LPFC_SLI4_FCF_TBL_INDX_MAX>
The FCF index is beyond the driver allocated FCF table.
ACTION: Report the error to Broadcom Technical Support.
2537 Receive Frame Truncated
Asynchronous frame received, but exceeded buffer length. Frame payload truncated.
ACTION: Report the error to Broadcom Technical Support.
3669 DMA buffer allocation failed for FW logging
DMA memory for storing the RAS firmware log is unavailable.
ACTION: Report the error to Broadcom Technical Support.
1423 HBA Unrecoverable error: uerr_lo_reg=<uerr_sta_lo>, uerr_hi_reg=<uerr_sta_hi>,
ue_mask_lo_reg=<ue_mask_lo>, ue_mask_hi_reg=<ue_mask_hi>
An unrecoverable HBA error is reported.
ACTION: Report the error to Broadcom Technical Support.
2930 Failed to get resource extents Status <lpfc_mbox_hdr_status> Add'l Status
<lpfc_mbox_hdr_add_status>
The mailbox command to get the resource extent from firmware has failed.
ACTION: Report the error to Broadcom Technical Support.
Broadcom
DRVVM-UG126-100
69
Emulex Drivers for VMware ESXi User Guide
2514 POST_RPI_HDR mailbox failed with status <shdr_status> add_status <shdr_add_status>, mbx status
<rc>
The POST_RPI_HDR mailbox is failed by the firmware.
ACTION: Report the error to Broadcom Technical Support.
0394 Failed to allocate CQ_EVENT entry
There is not enough driver resource to handle the completion queue event.
ACTION: Report the error to Broadcom Technical Support.
3262 RQ <queue_id> doorbell format not supported: <db_format>
The doorbell format is not supported for this receive queue.
ACTION: Report the error to Broadcom Technical Support.
4111 UNREG cmpl deferred clr <nlp_rpi> on NPort <nlp_DID> Data: <nlp_defer_did> <ndlp>
There is some deferred event to be processed after UNREG_LOGIN mailbox completion.
ACTION: No action required.
2886 HBA Error Attention on unsupported if type <if_type>
HBA error attention event is reported for the unsupported interface type.
ACTION: Report the error to Broadcom Technical Support.
0388 Not a valid WCQE code: <lpfc_cqe_code>
Received an invalid work queue completion queue entry from the firmware.
ACTION: Report the error to Broadcom Technical Support.
0299 Invalid SLI revision <sli_rev>
Driver identified an invalid SLI revision while executing.
ACTION: Report the error to Broadcom Technical Support.
3465 WQ<queue_id> doorbell format not supported: <db_format>
The doorbell format is not supported for this work queue.
ACTION: Report the error to Broadcom Technical Support.
0359 No entry from fast-path completion queue fcpcqid=<queue_id>
There is no entry in the completion queue.
ACTION: No action required.
2885 Port Status Event: port status reg <portstat_reg.word0>, port smphr reg <portsmphr>, error
1=<work_status[0]>, error 2=<work_status[1]>
Firmware has reported port status event.
ACTION: Report the error to Broadcom Technical Support.
0350 rc should have been MBX_BUSY
The driver is unable to post the UNREG_LOGIN mailbox to the firmware.
ACTION: Report the error to Broadcom Technical Support.
1438 UNREG cmpl deferred mbox <nlp_rpi> on NPort <nlp_DID> Data: <nlp_flag> <nlp_defer_did> <ndlp>
Check for any deferred event after UNREG_LOGIN mailbox completion.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
70
Emulex Drivers for VMware ESXi User Guide
0593 Error <rc> during rpi post operation
Error is encountered while posting the RPI header region into the firmware.
ACTION: Report the error to Broadcom Technical Support.
2758 Failed to allocate mbox for READ_FCF cmd
Memory for the READ_FCF command is not allocated.
ACTION: Report the error to Broadcom Technical Support.
0451 Adapter did not grant BlockGuard
The adapter firmware did not allow the driver to enable BlockGuard support. It is not a fatal error.
ACTION: No action required.
0599 Firmware Dump Image Present on Adapter
"Driver identified that a firmware dump image is present.
ACTION: No action required.
2616 txcmplq not empty<cnt> after <maxwait>
The completion queue is not yet drained after a particular time.
ACTION: No action required.
3468 Memory Allocated failed for FW logging
The memory is unavailable to store the firmware log buffer
ACTION: Report the error to Broadcom Technical Support.
2610 FCF <fcf_index> reached driver's book keeping dimension:< LPFC_SLI4_FCF_TBL_INDX_MAX>
The FCF index is beyond the driver allocated FCF table.
ACTION: Report the error to Broadcom Technical Support.
2920 Failed to alloc Resource IDs rc = <rc>
The port resources allocation itself has failed.
ACTION: Report the error to Broadcom Technical Support.
2925 Failed to issue CT ABTS RSP <Rctl> on xri <oxid>, Data <link_state>
The driver has failed to issue a CT ABTS response command.
ACTION: Report the error to Broadcom Technical Support.
3154 BLS ABORT RSP failed, data: <ulpStatus><iocb.un.ulpWord[4]>
The BLS ABORT response command has failed.
ACTION: Report the error to Broadcom Technical Support.
0283 Failed to allocate mbox cmd memory
The memory allocation from the mailbox slab has failed.
ACTION: Report the error to Broadcom Technical Support.
3169 Abort failed: Abort INP: Data: <sli4_xritag> <ulpIoTag> <ulpContext> <ulpCommand>
An abort is issued to the command for which an abort has already been issued.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
71
Emulex Drivers for VMware ESXi User Guide
3167 Abort failed: issue_iocb: Data: <sli4_xritag> <ulpIoTag> <ulpContext> <ulpCommand>
The driver has failed to post the abort request for a command.
ACTION: Report the error to Broadcom Technical Support.
2800 Ring <ringno> full - portCmdGet <local_getidx>, ring max <port_max_cmd>
The ring to post the pending commands is full.
ACTION: No action required.
3161 Failure to post els sgl to port.
The driver has failed to post the ELS SGL to the firmware.
ACTION: Report the error to Broadcom Technical Support.
0343 Ring <ringno> Cannot find buffer for an unsolicited iocb. tag <ulpWord[3]>
The driver does not have a buffer for processing an unsolicited command.
ACTION: No action required.
0342 Ring <ringno> Cannot find buffer for an unsolicited iocb. tag <sli3Words[7]>
The driver does not have a buffer for processing an unsolicited command.
ACTION: No action required.
0341 Ring <ringno> Cannot find buffer for an unsolicited iocb. tag <ulpWord[3]>
The driver does not have a buffer for processing an unsolicited command.
ACTION: No action required.
0340 Adapter temperature is OK now. temperature : <temperature> Celsius
The adapter has reported the temperature through an asynchronous event.
ACTION: No action required.
0347 Adapter is very hot, please take corrective action. temperature : %d Celsius, temperature
Adapter temperature is above normal range.
ACTION: Shutdown and remove the HBA. Contact Broadcom Technical Support.
0346 Ring <ringno> handler: unexpected ASYNC_STATUS evt_code <evt_code> W0 <iocb_w[0]> W1 <iocb_w[1]>
W2 <iocb_w[2]> W3 <iocb_w[3]> W4 <iocb_w[4]> W5 <iocb_w[5]> W6 <iocb_w[6]> W7 <iocb_w[7]> W8
<iocb_w[8]> W9 <iocb_w[9]> W10 <iocb_w[10]> W11 <iocb_w[11]> W12 <iocb_w[12]> W13 <iocb_w[13]> W14
<iocb_w[14]> W15 <iocb_w[15]>
The HBA received an asynchronous event that was not a temperature event.
ACTION: No action required.
0345 Resetting board, <event>
A mailbox command failed to complete. The driver is resetting the port.
ACTION: Report the error to Broadcom Technical Support.
0344 Ring <ringno> Cannot find buffer for an unsolicited iocb. tag <sli3Words[7]>
There are no more pre-allocated buffers available to handle unsolicited buffers.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
72
Emulex Drivers for VMware ESXi User Guide
2561 Allocated DMA memory size <alloclen> is less than the requested DMA memory size <reqlen>
Could not get the memory required for the number of XRIs that are attempting to be posted.
ACTION: No action required.
3033 Allocated DMA memory size <alloclen> is less than requested <reqlen>
Could not get the memory required for posting a read object mailbox command.
ACTION: No action required.
0349 rc should be MBX_SUCCESS
The next mailbox command on the mailbox queue has failed.
ACTION: No action required.
3367 LWPD Memory Allocation Failed for FW Logging
The DMA memory allocation for getting firmware logging has failed.
ACTION: No action required.
2564 POST_SGL_BLOCK mailbox command failed status <shdr_status> add_status <shdr_add_status> mbx
status <rc>
The list of XRI SGEs failed to be registered with the firmware.
ACTION: No action required.
3362 LUN queue depth changed from <cfg_lun_queue_depth> to <rc>
The user configured LUN queue depth is beyond the allowable value. Reset the value to the maximum allowable value.
ACTION: No action required.
0582 Error <Status string> during els sgl post operation
The driver has failed to post the ELS SGL to the firmware.
ACTION: Report the error to Broadcom Technical Support.
3089 Failed to allocate queues
The driver has failed to allocate the queue required for posting the command requests.
ACTION: Report the error to Broadcom Technical Support.
3084 Allocated DMA memory size <alloclen> is less than the requested DMA memory size <reqlen>
Could not get enough memory to read the port attributes.
ACTION: No action required.
2001 Unable to allocate memory for issuing SLI_CONFIG_SPECIAL mailbox command
The memory allocation for the SLI_CONFIG_SPECIAL mailbox command has failed.
ACTION: Report the error to Broadcom Technical Support.
2512 MODIFY_EQ_DELAY mailbox failed with status <shdr_status> add_status <shdr_add_status>, mbx status
<rc>
The mailbox command to modify the interrupt coalescing status has failed.
ACTION: No action required.
1806 Mbox <mbxCommand> failed. No vport
The mailbox command posting failed as it does not have the vPort information.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
73
Emulex Drivers for VMware ESXi User Guide
3024 Read Object mailbox failed with status <shdr_status> add_status <shdr_add_status>, mbx status <rc>
The read object mailbox is failed by the firmware.
ACTION: No action required.
2015 Invalid CT <ulpCt> command <ulpCommand>
Invalid command-type in the IOCB is not supported.
ACTION: No action required.
0410 Cannot find virtual addr for mapped buf on ring <ringno> Data <phys_addr> <postbufq_next>
<postbufq_prev> <postbufq_cnt>
The driver cannot find the specified buffer in its mapping table. Therefore, it cannot find the virtual address needed to access the data.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists report these errors to Broadcom Technical
Support.
7646 HA Read Err: HA: <HAregaddr>
Failed to read the host attention register.
ACTION: No action required.
7645 Read failure HS: %p MB: %p\n, (void *)phba->HSregaddr, (void *)phba->MBslimaddr)
Failed to read the host status register.
ACTION: No action required.
3175 Abort IGNORED: Data: <sli4_xritag> <ulpIoTag> <ulpContext> <ulpCommand>
As the driver is being unloaded, the request to abort the outstanding commands are ignored.
ACTION: No action required.
3282 Invalid provisioning of vfi: <count>
The firmware reported an invalid value for the port resource VFI.
ACTION: This error could indicate a firmware issue. If this issue persists report these errors to Broadcom Technical Support.
3281 Invalid provisioning of xri: <count>
The firmware reported an invalid value for the port resource XRI.
ACTION: This error could indicate a firmware issue. If this issue persists report these errors to Broadcom Technical Support.
3280 Invalid provisioning of vpi: <count>
The firmware reported an invalid value for the port resource VPI.
ACTION: This error could indicate a firmware issue. If this issue persists report these errors to Broadcom Technical Support.
0809 <function_name>: out of buffers! Failing completion.
The driver has failed to get the IOCB buffer.
ACTION: No action required.
0376 READ_REV Error. SLI Level <sli_rev> FCoE enabled <hba_flag & HBA_FCOE_MODE>
The SLI revision reported by the firmware for this port is invalid.
ACTION: This error could indicate a software driver or firmware issue. If this issue persists report these errors to Broadcom Technical
Support.
Broadcom
DRVVM-UG126-100
74
Emulex Drivers for VMware ESXi User Guide
0377 Error <rc> parsing vpd. Using defaults.
Could not parse the VPD data, so the driver is using the default values.
ACTION: No action required.
2823 txq empty and txq_cnt is <txq_cnt>
No more pending commands in the transaction wait queue.
ACTION: No action required.
0370 Invalid completion queue type <type>
The event queue entry is not for a mailbox or a work queue entry.
ACTION: No action required.
3370 FW LOG mailbox completed with status <shdr_status> add_status <shdr_add_status>, mbx status
<mbxStatus>
Enabling firmware logging in host memory failed.
ACTION: No action required.
2752 KILL_BOARD command failed retval <retval>
The KILL_BOARD mailbox command is failed by the firmware.
ACTION: report the error to Broadcom Technical Support.
2022 INIT VPI Mailbox failed status <rc>, mbxStatus <lpfc_mqe_status>
The INIT VPI mailbox command has failed.
ACTION: No action required.
2751 Adapter failed to restart, status reg <status>, FW Data: A8 <offset_A8> AC <offset_AC>
The adapter initialization has failed.
ACTION: Try to reset the port. If this issue persists report the error to Broadcom Technical Support.
2515 ADD_FCF_RECORD mailbox failed with status <rc>
The mailbox command to add the FCF record has failed.
ACTION: No action required.
2510 RQ_DESTROY mailbox failed with status <shdr_status> add_status <shdr_add_status>, mbx status <rc>
The mailbox command sent to delete the work queue has failed.
ACTION: No action required.
2511 POST_SGL mailbox failed with status <shdr_status> add_status <shdr_add_status>, mbx status <rc>
The mailbox command sent to post the SGL pages to the firmware has failed.
ACTION: No action required.
0572 iotag <iotag> out of range, Max is <last_iotag>
The I/O tag in the completed IOCB is out of range.
ACTION: This error could indicate a software driver, firmware, or a hardware issue. Report the error to Broadcom Technical Support.
2513 POST_SGL_BLOCK mailbox command failed status <shdr_status> add_status <shdr_add_status> mbx
status <rc>
The mailbox command sent to post the SGL pages to the firmware has failed.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
75
Emulex Drivers for VMware ESXi User Guide
2860 SLI authentication is required for INIT_LINK but has not done yet
The INIT_LINK mailbox command has failed and the link may not be up.
ACTION: Report the error to Broadcom Technical Support.
0390 iotag <iotag> does not map to outstanding IO. last cmd <ulpCommand>, XRI <sli4_xritag>, wqidx
<fcp_wqidx>, flag <iocb_flag>
The I/O tag does not map to the outstanding I/O list of the driver.
ACTION: This error could indicate a software driver, firmware, or a hardware issue. Report the error to Broadcom Technical Support.
1807 IOCB <> failed. No vport
The IOCB does not have the vPort reference in it.
ACTION: This is a software issue. Report the error to Broadcom Technical Support.
6771 PCIe Read from <addr> succeeded after <retry_cnt> attempts
The PCIe read of an address succeeded after certain number of attempts.
ACTION: No action required.
Broadcom
DRVVM-UG126-100
76
Emulex Drivers for VMware ESXi User Guide
Appendix A: esxcli Management Tool
A.1 Usage
The esxcli management tool supports both local and remote management.

Local management
esxcli elxmgmt <command> <parameters>

Remote management
To manage the ESXi system directly, use the following command:
esxcli -s <server> -u <username> -p <password> -d <thumbprint> elxmgmt <command>
<parameters>
To manage the ESXi system using a vCenter server, use the following command:
esxcli -s <vCenter_server> -u <username> -p <password> -h <VI_HOST> -d <thumbprint>
elxmgmt <command> <parameters>
Table 9: Available Namespaces
Namespace
Description
authconfig
Authentication features of an Emulex FC HBA.
driverparams
Driver parameters of an Emulex FC HBA.
hba
HBA associated features of an Emulex FC HBA.
hbaport
Port associated features of an Emulex FC HBA.
beacon
Beacon state of an Emulex FC HBA.
bootparams
Boot parameters for a given port and given boot type for an Emulex FC HBA.
dumpdirectory
Dump file directory for an Emulex FC HBA in the host.
fwlog
Firmware logging for a particular port of an Emulex FC HBA.
fwparams
Firmware parameters of an Emulex FC HBA.
trunkinfo
Trunking operations for an LPe35000-series adapter.
version
Returns the version of the tool and dependent libraries.
xcvrdata
Transceiver data of an Emulex FC HBA.
Broadcom
DRVVM-UG126-100
77
Emulex Drivers for VMware ESXi User Guide
A.2 esxcli Management Commands
The commands listed are for local management only. You can add the remote management parameters to the local
commands for remote management.
The following table contains a list of esxcli management commands and their descriptions.
Table 10: esxcli Management Commands
Command
Description
authconfig delete -w <initiator wwpn>
Sets delete authentication for a specified HBA port.
authconfig get -w <initiator wwpn>
-d <target wwpn>
Shows the authentication configuration details.
 d specifies the destination WWPN. It must be ff:ff:ff:ff:ff:ff:ff:ff
for a switch or the actual WWPN for a target.
authconfig initiate -w <initiator wwpn> Initiates authentication for a specified HBA port.
-d <target wwpn>
 d specifies the destination WWPN. It must be ff:ff:ff:ff:ff:ff:ff:ff
for a switch or the actual WWPN for a target.
authconfig lst -w <wwpn>
Shows the authentication configuration list.
authconfig remove -w <wwpn>
-e <entity pair>
Sets delete authentication from an entity pair for a specified HBA port.
 e specifies the entity pair: (localEntity, remoteEntity)
– localEntity: Source WWPN.
– remoteEntity: Destination WWPN or all.
– all deletes the entire authentication configuration.
NOTE: This command is not supported on LPe12000-series adapters.
authconfig secret set -w <initiator
wwpn> -d <target wwpn> -f <flag>
-t <new secret type>
-v <new secret value>
Sets the authentication configuration password for a specified HBA port.
 d specifies the destination WWPN. It must be ff:ff:ff:ff:ff:ff:ff:ff
for a switch or the actual WWPN for a target.
 f specifies the flag. Valid values are (1, 2).
– 1 = Local; the password is used when the HBA initiates authentication to
the switch and when using bidirectional authentication.
– 2 = Remote; the password is used when the switch initiates authentication
to the HBA and when using bidirectional authentication (required).
 t specifies the new secret type. Valid values are (1, 2).
– 1 = ASCII.
– 2 = Hexadecimal (binary).
v specifies the new secret value.
Broadcom
DRVVM-UG126-100
78
Emulex Drivers for VMware ESXi User Guide
Table 10: esxcli Management Commands (Continued)
Command
Description
authconfig set -w <initiator wwpn> -d
<target wwpn> -b <bi-directional>
-p <dh-priority> -s <hash-priority>
-m <mode> -r <re-authentication>
-a <re-authentication-interval>
-t <timeout>
Sets the authentication configuration parameters for a specified HBA port.
 d specifies the destination WWPN. It must be ff:ff:ff:ff:ff:ff:ff:ff
for a switch or the actual WWPN for a target.
 b specifies bidirectional. Valid values are (disabled, enabled).
 p specifies dh-priority: (1, 2, 3, 4, 5), any combinations up to five digits.
(4321 specifies a priority of 1536:1280:1024:Null)
1 = Null
2 = 1024
3 = 1280
4 = 1536
5 = 2048
 s specifies the hash-priority. Valid values are (md5, sha1).
md5 = First md5, then sha1.
sha1 = First sha1, then md5.
 m specifies the mode. Valid values are (disabled, enabled, passive).
 r specifies the re-authentication mode. Valid values are (disabled, enabled).
 a specifies the re-authentication time interval in minutes. Valid values are (0,
10 to 3,600).
0 = Disables re-authentication.
t specifies the timeout value in seconds.
authconfig status get -w <initiator
wwpn> -d <target wwpn>
Shows the authentication configuration status details.
 d specifies the destination WWPN. It must be ff:ff:ff:ff:ff:ff:ff:ff
for a switch or the actual WWPN for a target.
beacon get -w <wwpn>
Shows the beacon state of an Emulex FC HBA.
beacon set -w <wwpn> -s <state> [-d
<duration>]
Sets the beacon state of an Emulex FC HBA.
 s specifies the state of the beacon. The default is 1. Valid values are:
– 1 = Beacon on (mandatory).
– 0 = Beacon off.
 d specifies the duration of beaconing. The maximum duration is 65,535
seconds. The default is 0 for infinite beaconing. This is an optional parameter.
bootparams get -w <wwpn> -t <boot type> Shows the boot parameters for a given port and given boot type.
 t specifies the boot type: {X86, EFI, OB}.
Broadcom
DRVVM-UG126-100
79
Emulex Drivers for VMware ESXi User Guide
Table 10: esxcli Management Commands (Continued)
Command
Description
bootparams set -w <wwpn> -p <parameter> Sets the boot parameter and boot type for the specified HBA port.
-t <type> -v <value> - b <boot_device>  p specifies the parameter name.
 t specifies the boot type: {X86, EFI, OB}.
 v specifies the value to be set for the parameter.
Parameter name, supported boot type, and valid values are as follows:
– DefaultAlpa
X86/OB
{ Value }
– EnableAdapterBoot
All
{ State } (0=Disable, 1=Enable)
– EnableBootFromSan
All
{ State } (0=Disable, 1=Enable)
– LinkSpeed
All
{ 0, 1, 2, 4, 8 }
– PlogiRetryTimer
All
{ 0, 1, 2, 3 }
– Topology
All
{ 0, 1, 2, 3 }
NOTE:
The Topology parameter is supported only on LPe12000-series
adapters.
– AutoScan
X86
{ 0, 1, 2, 3 }
– AutoBootSectorEnable
X86
{ State } (0=Disable, 1=Enable)
– EDD30Enable
X86
{ State } (0=Disable, 1=Enable)
– EnvVarEnable
X86
{ State } (0=Disable, 1=Enable)
– SpinupDelayEnable
X86
{ State } (0=Disable, 1=Enable)
– StartUnitCommandEnable
X86
{ State } (0=Disable, 1=Enable)
– BootTargetScan
EFI
{ 0, 1, 2, 3, 4 }
Broadcom
DRVVM-UG126-100
80
Emulex Drivers for VMware ESXi User Guide
Table 10: esxcli Management Commands (Continued)
Command
Description
– EnableFABL
EFI
{ State } (0=Disable, 1=Enable)
– MaxLunsPerTarget
EFI
{ Value }
– DelayDeviceDiscovery
EFI
{ Value }
– SfsFlag
OB
– { State } (0=Disable, 1=Enable)
Boot Device Parameters
– D_ID
All
{Value [BootDev Value2]}
– LUN
All
{Value [BootDev Value2]}
– TargetWWPN
All
{Value [BootDev Value2]}
– TargetID
OB
{Value }
 b specifies the boot device entry number { 0 -7 } as shown in the output of the
bootparams get command.
driverparams defaults set -w <wwpn>
-s [L,G] -t [P,T]
Restores the driver parameter to the default value at the port or global level, either
permanently or temporarily for the specified port.
 s specifies the scope.
– L for local (specified adapter).
– G for global (all adapters on the host).
 t specifies the nature of the setting.
– P for permanent (persists across reboot).
– T for temporary.
driverparams get -w <wwpn>
Shows the name and values of each parameter.
driverparams global get -w <wwpn>
Shows the name and global values of each parameter.
driverparams set -w <wwpn> -s [L,G] -t
[P,T]-p <parameter name> -v <value>
Changes a driver parameter and designates the scope of the change.
 s specifies the scope.
– L for local (specified adapter).
– G for global (all adapters on the host).
 t specifies the nature of setting.
– P for permanent (persists across reboot).
– T for temporary.
 p specifies the parameter name.
 v specifies the value to be set for the parameter. Input must be a decimal
value; otherwise, to input a hexadecimal value, add a prefix of 0x to the input.
dumpdirectory get
Displays the dump directory for the adapters in the host.
Broadcom
DRVVM-UG126-100
81
Emulex Drivers for VMware ESXi User Guide
Table 10: esxcli Management Commands (Continued)
Command
Description
dumpdirectory set -d <dump_directory>
Sets the dump directory.
A dump directory must be set before a dump can be taken.
NOTE: The dump directory must have a subdirectory under the /vmfs/volumes
directory to store Emulex HBA Manager dumps and the directory must exist at the
time of setting. The directory path must not contain spaces.
firmware dump -w <wwpn>
Creates a diagnostic dump for a selected adapter. Dump files contain information
such as the firmware version, driver version, and operating system information.
This information is useful when troubleshooting an adapter. Text (.txt extension)
and binary files (.bin extension) files are created with the dump command.
NOTE: The dump directory must be explicitly set before a dump operation can
succeed. If a dump operation is performed without setting a dump directory, an
error message is displayed. For information on setting a dump directory, see the
dumpdirectory set command.
NOTE: If there are multiple dumps in the flash memory of an adapter, the
command generates multiple .txt and .bin files.
NOTE: This command replaces the dump command.
fwlog get -w <wwpn>
Stops the firmware log capture, retrieves the log to the dump directory, and restarts
firmware log capture for a specified HBA port.
fwlog set -w <wwpn> -l <log_level>
-s <state>
Starts or stops the firmware logging with the specified log level for a specified HBA
port.
 l specifies the logging level of the firmware log. Valid values are 0 to 4. The
log level determines the verbosity of the logs. 0 is the least verbose.
 s specifies firmware logging. Valid values are:
– 1 = Start firmware logging.
– 0 = Stop firmware logging.
fwparams get -w <wwpn>
Shows the firmware parameters that can be set from the management layer.
fwparams set -w <wwpn> -p <parameter
name> -v <parameter value>
Sets the firmware parameters. The only firmware parameter that is currently
supported is FA-PWWN.
 p specifies the name of firmware parameter whose value is to be set. Valid
values are:
– FA-PWWN = {0=Disable, 1=Enable}.
– FEC = {0=Disable, 1=Enable}.
– DYNAMIC-DPORT = {0=Disable, 1=Enable}
 v specifies the new value for the specified firmware parameter.
NOTE: D_Port and FA-PWWN cannot be enabled simultaneously. If D_Port is
enabled and you want to enable FA-PWWN, you must first disable D_Port. If
FA-PWWN is enabled and you want to enable D_Port, you must first disable
FA-PWWN.
hba attributes get -w <wwpn>
Lists HBA attributes of an Emulex FC HBA.
NOTE: This command replaces the hbaattributes command.
hba firmware download -w <wwpn> -f
<firmware pathname>
Performs firmware download on to the adapter.
 f specifies the fully qualified path to the firmware file.
NOTE: This command replaces the download command.
hba list
Lists the Emulex FC HBAs.
NOTE: This command replaces the listhbas command.
hbaport allnodeinfo list -w <wwpn>
Shows the target node information for each target accessible by the adapter.
NOTE: This command replaces the allnodeinfo command.
hbaport attributes -w <wwpn>
Lists port attributes of an Emulex FC HBA.
Broadcom
DRVVM-UG126-100
82
Emulex Drivers for VMware ESXi User Guide
Table 10: esxcli Management Commands (Continued)
Command
Description
hbaport bootcode -w <wwpn> -s <state>
Enables or disables boot code on the adapter port.
 s specifies the state of the boot code. Possible values are E and D.
– E = Enable.
– D = Disable.
NOTE: This command replaces the enablebootcode command.
hbaport disable -w <wwpn> -p <portstate> Disables the adapter port for a specified HBA port.
 p specifies the port state as Disable 0.
NOTE: Ensure that all I/O on the port is stopped before disabling the port.
NOTE: A port reset may be required to activate the new setting.
hbaport dporttest start -w <wwpn>
Sets of diagnostic tests that allows detection of physical cabling issues.
NOTE: This command replaces the dporttest command.
hbaport echotest start -w <initiator
wwpn>
-d <target wwpn> -c <number of cycles>
-s <stop on error flag> [-p pattern]
Runs the echo test on FC functions. The hbaport echotest start command
fails if the target WWPN does not support the ECHO ELS command.
 d specifies the destination WWPN. It must be ff:ff:ff:ff:ff:ff:ff:ff
for a switch or the actual WWPN for a target.
 c specifies the count or number of cycles {1....99999}.
 s specifies StopOnError: {0, 1}.
– 0 = Do not stop test on error.
– 1 = Stop test on error.
 p specifies pattern with up to 8 hexadecimal characters (for example,
1a2b3c4d). This is an optional parameter. The number of cycles must be
between 1 and 99,999.
NOTE: The <target wwpn> is the WWPN of the target port and can be obtained
by running the hbaport targetmapping list command.
NOTE: This command replaces the echotest command.
hbaport enable -w <wwpn> -p <portstate> Enables the adapter port for a specified HBA port.
 p specifies the port state as Enable 1.
NOTE: Ensure that all I/O on the port is stopped before enabling the port.
NOTE: A port reset may be required to activate the new setting.
hbaport fctraceroute get -w <initiator
wwpn> -d <target wwpn>
Broadcom
Shows the FC trace route details between the adapter port and the specified target
port.
 d specifies the destination WWPN. It must be ff:ff:ff:ff:ff:ff:ff:ff
for a switch or the actual WWPN for a target.
NOTE: This command replaces the fctraceroute command.
DRVVM-UG126-100
83
Emulex Drivers for VMware ESXi User Guide
Table 10: esxcli Management Commands (Continued)
Command
Description
hbaport loopbacktest start
Runs loopback tests on FC functions.
-w <initiator wwpn> -d <target wwpn>
 d specifies the destination WWPN. It must be ff:ff:ff:ff:ff:ff:ff:ff
-c <number of cycles> -s <stop on error
for a switch or the actual WWPN for a target.
flag> [-p pattern]-o <statistics
 c specifies the count or number of cycles {1....99999}. Infinite loop is not
option> -t <type>
supported.
 s specifies StopOnError: {0, 1}.
– 0 = Do not stop test on error.
– 1 = Stop test on error.
 p specifies pattern with up to 8 hexadecimal characters (for example,
1a2b3c4d). This is an optional parameter. The number of cycles must be
between 1 and 99,999.
 o specifies the link statistics option (optional, advanced). Contact Broadcom
Technical Support before you use this option.
 t specifies the HBA test: {0, 1, 2}
– 0 = PCI LoopBack test.
– 1 = Internal LoopBack test.
– 2 = External LoopBack test (requires loopback plug)
NOTE: The <target wwpn> is the WWPN of the target port and can be obtained
by running the hbaport targetmapping list command.
NOTE: This command replaces the loopbacktest command.
hbaport reset -w <wwpn>
Resets the FC function.
NOTE: This command replaces the reset command.
hbaport speed set -w <wwpn> -s<speed>
Sets port speed of an Emulex FC HBA.
 s specifies the supported link speed.
Use the hbaport attributes command to get accurate list of supported
speed values. Specify a value of 0 to configure Auto Detect mode.
NOTE: A port reset is required to activate the new setting.
hbaport statistics -w <wwpn>
NOTE: Lists port statistics of an Emulex FC HBA.
hbaport statistics reset -w <wwpn>
Resets the FC port statistics.
NOTE: This command replaces the resetportstatistics command.
hbaport targetmapping list -w <wwpn>
Shows a list of mapped targets and the LUNs for the port.
NOTE: This command replaces the targetmapping command.
resetportstatistics -w <wwpn>
Resets the FC port statistics.
trunkinfo get -w <wwpn>
Shows the complete trunking configuration of a physical port or trunked port
specified by the WWPN on an LPe35000 adapter.
trunkinfo set -w <wwpn> -m <mode>
Specifies the type of trunking to use for a specified HBA port on an LPe35000
adapter.
 m specifies the trunking mode: (0, 1, 2)
– 0 = Disables trunking on the adapter.
– 1 = Enables two-lane trunking.
– 2 = Enables four-lane trunking (only valid for quad-port adapters)
version
Displays the version of different components.
version get
Shows the version of the tool and dependent libraries.
xcvrdata get -w <wwpn> [-t <type>]
Shows the transceiver data in raw or formatted output.
Broadcom
DRVVM-UG126-100
84
Emulex Drivers for VMware ESXi User Guide
Appendix B: lpfc Driver BlockGuard Functionality
This appendix describes how to enable BlockGuard and set lpfc driver module parameters.
B.1 Overview
The BlockGuard feature checks the integrity of data read from and written to the host to the disk and back through the SAN.
This check is implemented through the DIF defined in the ANSI T10 standard.
The Emulex lpfc driver supports T10 DIF Type 1. In the Type 1 implementation, the 8-byte DIF consists of a Ref tag or LBA,
an App tag, and a Guard tag (or CRC). A Type 1 DIF is defined as having a 2-byte Guard tag, a 2-byte App tag, and a
4-byte Ref tag, which consist of the lower 32 bits of the LBA.
The following figure shows a data block (with a 512-byte sector) with the 8-byte footer attached to the end. The contents of
the 8-byte footer are shown with the fields that make up the Type 1 DIF; the Guard tag, the App tag, and the Ref tag. The
App tag is not used by the lpfc driver.
Figure 1: Data Block Showing Type 1 DIF
When data is written, the DIF is generated by the host, or by the adapter, based on the block data and the LBA. The DIF
field is added to the end of each data block, and the data is sent through the SAN to the storage target. The storage target
validates the CRC and Ref tag and, if correct, stores both the data block and DIF on the physical media. If the CRC does
not match the data, the data was corrupted during the write. A Check Condition is returned to the host with the appropriate
error code. The host records the error and retransmits the data to the target. In this way, data corruption is detected
immediately on a write and is never committed to the physical media. On a read, the DIF is returned along with the data
block to the host, which validates the CRC and Ref tags. Because this validation is done by the hardware, it adds a very
small amount of latency to the I/O.
The format of the Guard tag can optionally be an IP checksum instead of the CRC mandated by the T10 DIF. This can be
beneficial because the initiator host uses less CPU overhead to generate an IP checksum than it does with a CRC. The IP
checksum is typically passed as the Guard tag between the initiator host and the adapter. The adapter hardware will translate
the IP checksum into a CRC, or vice versa, on data being sent to or received from on the wire. The CRC is called a DIF
protection type, and the IP checksum is referred to as a DIX protection type.
Broadcom
DRVVM-UG126-100
85
Emulex Drivers for VMware ESXi User Guide
B.2 Enabling BlockGuard
BlockGuard is disabled by default. To enable it, the parameter lpfc_enable_bg must be passed to the driver as follows:
esxcli system module parameters set -m lpfc -p "lpfc_enable_bg=1"
Additional module parameters can be added to this line, separated by spaces.
B.3 SCSI Command Support – SCSI Operation Codes
When there are both READ and WRITE requests, the CDB passed to the adapter from the initiator host has a read protect/
write protect (RDPROTECT/WRPROTECT) field that indicates to the target whether to perform data integrity verification. It also
indicates whether to transfer protection data between initiator and target. The adapter does not know if a target supports
protection information or the type of protection it has been formatted. The initiator host, which has this knowledge, will always
prepare a CDB with the appropriate RDPROTECT/WRPROTECT information, depending on target format and capabilities. The
request also includes information about the protection type that the target has been formatted.
In addition, the initiator host will also provide the adapter with an operation code that tells the controller how to place the
protection data for the type of I/O to perform. Each I/O is logically a two-step process. The data is transferred between the
initiator host and the adapter (over the PCI bus) and between the adapter and the target (over the SAN) as shown in the
following figure. The type of operation defines whether the data transfer has protection data.
Figure 2: Data Transfer between the Initiator Host and the Adapter
The initiator operations are listed in the following table.
Table 11: Initiator Operations
Initiator Operation
Initiator Host <-> Adapter Adapter <-> Target
NORMAL
Unprotected
Unprotected
Used for unprotected I/O.
READ_INSERT
Protected
Unprotected
Reads the data from the target. The adapter then
generates the protection data and transfers both data
and protection data to the initiator host. No protection
data is sent on the SAN. The adapter can insert the
protection data Guard tag as CRC or IP CSUM.
READ_PASS
Protected
Protected
Reads the data and the protection data from the target
on the SAN. The adapter verifies data integrity and
transfers both data and the protection data to the initiator
host. The adapter can convert the protection data Guard
tag from CRC to IP CSUM.
Broadcom
Comment
DRVVM-UG126-100
86
Emulex Drivers for VMware ESXi User Guide
Table 11: Initiator Operations (Continued)
Initiator Operation
Initiator Host <-> Adapter Adapter <-> Target
Comment
READ_STRIP
Unprotected
Protected
Reads the data and protection data from the target. The
adapter verifies data integrity, discards protection data,
and transfers only the data to the initiator host. It does
not send the protection data to the initiator host.
Protection data is sent only on the SAN.
WRITE_INSERT
Unprotected
Protected
Transfers the data from the initiator host. The adapter
then generates protection data and writes both the data
and protection data to the target. Protection data is sent
only on the SAN.
WRITE_PASS
Protected
Protected
Transfers the data and protection data from the initiator
host to the adapter. The adapter verifies protection data
and writes both data and protection data to the target on
the SAN. The adapter can convert the protection data
Guard tag from IP CSUM to CRC.
WRITE_STRIP
Protected
Unprotected
Transfers data and protection data from the initiator host.
The adapter verifies data integrity, discards protection
data, and writes only the data to the target. No protection
data is sent on the SAN.
B.4 lpfc Driver Module Parameters
The lpfc driver has two module parameters: lpfc_prot_mask and lpfc_prot_guard. Using these parameters, you
can control which DIF capabilities the lpfc driver registers with the ESXi SCSI subsystem. This, in turn, controls which
initiator operations (BlockGuard profiles) are used during I/O operations. These parameters are set up when the driver loads
and cannot be changed while the driver is running.
B.4.1 lpfc_prot_mask
This parameter controls the DIF operations that the driver registers with the hypervisor. The hypervisor selects an operation
to use for each I/O command that matches the adapter DIF capability. The driver indicates its capabilities by the operations
that it registers with the hypervisor.
If the parameter is not passed to the driver, the default results in registering capabilities for all profiles.
The SCSI layer will typically use the bit masks listed in the following table to determine how to place the protection data
associated with I/Os to the SCSI host.
Table 12: lpfc_prot_mask Protection Types
Flag
Value
Indicates
VMK_SCSI_TYPE1_PROT
1
Adapter supports T10 DIF Type 1
Adapter-to-target Type 1 protection
VMK_SCSI_DIX_TYPE0_PROT
8
Adapter supports DIX Type 0
Host-to-adapter protection only
VMK_SCSI_DIX_TYPE1_PROT
16
Adapter supports DIX Type 1
Host-to-adapter Type 1 protection
Broadcom
Description
DRVVM-UG126-100
87
Emulex Drivers for VMware ESXi User Guide
The following table shows how protection data gets placed for each supported profile.
Table 13: Protection Data Placement for Supported Profiles
Flag
Value
BlockGuard Profile
Operation
VMK_SCSI_TYPE1_PROT
1
A1
READ_STRIP/WRITE_INSERT
VMK_SCSI_DIX_TYPE0_PROT
8
AST2
READ_INSERT/WRITE_STRIP
VMK_SCSI_DIX_TYPE1_PROT
VMK_SCSI_TYPE1_PROT
17
AST1 / C1
READ_PASS/WRITE_PASS
B.4.2 lpfc_prot_guard
This parameter specifies the type of CRC that the ESXi hypervisor passes to the lpfc driver. The following table shows the
three guard types: CRC, IP CSUM, and TYPE_ALL with values of 0x1, 0x2, and 0x3 respectively.
Table 14: lpfc_prot_guard Guard Types
Flag
Value
Indicates
VMK_SCSI_GUARD_CRC
1
Adapter supports T10 DIF CRC
VMK_SCSI_GUARD_IP
2
Adapter supports both T10 DIF CRC and IP CSUM
VMK_SCSI_GUARD_TYPE_ALL_VALID
3
Adapter supports both T10 DIF CRC and IP CSUM
The default value for lpfc_prot_guard is VMK_SCSI_GUARD_TYPE_ALL_VALID, which results in registering capabilities
for all guard types. This value defines the format for the Guard tag when the data is transferred between the host and the
adapter. When data is transferred on the wire, the protection data Guard tag is always translated into a T10 DIF CRC.
The SCSI layer typically uses an IP CSUM as the method for computing the protection data Guard tag because it uses less
CPU overhead.
Broadcom
DRVVM-UG126-100
88
Emulex Drivers for VMware ESXi User Guide
Appendix C: Using the VMID Feature on a Brocade Switch
This appendix describes the setup required for the Broadcom ECD VMID feature to work on a Brocade switch.
NOTE:
The Broadcom ECD VMID feature is not supported on the LPe12000-series adapters.
1. Set up the Brocade switch.
a. You must install firmware version 8.0.1 or later.
b. The Broadcom ECD VMID feature is enabled by default on Brocade switches.
2. Set up the target.
Use an FC target that supports the VMID feature. VMID requires a VMID-supported target and initiator to work.
3. Set up the initiator.
Set up the driver parameters to enable VMID on your ESXi host. For example:
# esxcli system module parameters set -p "lpfc_max_vmid=8 lpfc_vmid_app_header=1" -m lpfc
lpfc_max_vmid is the driver parameter that indicates the number of VMID VMs supported.
– The minimum value is 4.
– The maximum value is 255.
– The default value is 8.
lpfc_vmid_app_header is the driver parameter that enables Brocade VMID support on ESXi.
– The minimum value is 0 (default).
– The maximum value is 1.
4. After you have set the parameters, reboot the system for the changes to take effect.
5. Map a LUN from the FC target to a VM.
6. You can view the VMID of the VM whose LUN you have mapped in the earlier step using the following command:
# esxcli elxfc vmid get -n vmhba<X>
Output similar to the following is shown:
Key 'vmid':
lpfc VMID page: on
ID00 READs:000000000001c611 WRITEs:0000000000000000
UUID:
35322065312062302036662038632035662036362036612d3739206333206139206636203332203464203139203230
String (52 e1 b0 6f 8c 5f 66 6a-79 c3 a9 f6 32 4d 19 20)
Application id: 209
Last access time: 2016-10-25T10:58:05
Compressed: 52e1b06f8c5f666a79c3a9f6324d1920
7. On the Brocade switch, you can run the following command to verify the list of VMIDs:
> /fabos/cliexec/appserver --show -all
Broadcom
DRVVM-UG126-100
89
Emulex Drivers for VMware ESXi User Guide
Output similar to the following is shown:
-----------------------------------------------------------Displaying results for Fabric
-----------------------------------------------------------N_Port ID : 7e1200
Entity Name :
Entity ID (ASCII) : 52 e1 b0 6f 8c 5f 66 6a-79 c3 a9 f6 32 4d 19 20
Entity ID (Hex) :
0x35322065312062302036662038632035662036362036612d37392063332061392066362033322034642031392032300
0
Application ID : 0x00000209h (521)
------------------------------------------------------------Application Server displays 1 entries
Broadcom
DRVVM-UG126-100
90
Emulex Drivers for VMware ESXi User Guide
Appendix D: Using the VMID Feature on a Cisco Switch
This appendix describes the setup required for the Broadcom ECD VMID feature to work on a Cisco switch.
NOTE:
The Broadcom ECD VMID feature is not supported on the LPe12000-series adapters.
1. Set up the Cisco switch.
a. You must install firmware version 8.2 or later.
b. The Broadcom ECD VMID feature is not enabled by default on Cisco switches. Run the following command once to
configure VMIS globally on your switch:
switch(config)# feature vmis
2. Set up the target.
Use an FC target that supports the VMID feature. VMID requires a VMID-supported target and initiator to work.
3. Set up the initiator.
Set up the driver parameters to enable VMID on your ESXi host.
For example:
# esxcli system module parameters set -p "lpfc_max_vmid=8, lpfc_vmid_priority_tagging=1" -m lpfc
lpfc_max_vmid is the driver parameter that indicates the number of VMID VMs supported.
– The minimum value is 4.
– The maximum value is 255.
– The default value is 8.
lpfc_vmid_priority_tagging is the driver parameter that enables Cisco VMID support on ESXi. The possible
values are:
– 0 = Disabled (default).
– 1 = Priority tagging for targets that support it in their PLOGI LS_ACC response.
– 2 = Priority tagging for all targets, whether they support PLOGI LS_ACC.
4. After you have set the parameters, reboot the system for the changes to take effect.
5. Map a LUN from the FC target to a VM.
6. You can view the VMID of the VM whose LUN you have mapped in the earlier step using the following command:
# esxcli elxfc vmid get -n vmhba<X>
Output similar to the following is shown:
lpfc VMID page: on
VMID priority ranges:
[x1 - xff], qos: x0
VEM ID: 10:00:00:90:fa:c7:aa:b8:20:00:00:90:fa:c7:aa:b8
ID00 READs:000000000005e853 WRITEs:000000000005e879
UUID:
35302030372032352037332033382036652032392036612d3063203237203466203361203463203363203838206561
String (50 07 25 73 38 6e 29 6a-0c 27 4f 3a 4c 3c 88 ea)
CS_CTL VMID: x1
Last access time: 2018-05-14T09:49:42
Compressed: 50072573386e296a0c274f3a4c3c88ea
7. On the Cisco switch, you can run the following command to get the mapping between, the FCID and the WWPN:
(config-if)# show flogi database details
Broadcom
DRVVM-UG126-100
91
Emulex Drivers for VMware ESXi User Guide
Output similar to the following is shown:
-------------------------------------------------------------------------------------------INTERFACE
VSAN
FCID
PORT NAME
NODE NAME
FLAGS
-------------------------------------------------------------------------------------------fc3/4
102
0x010025 10:00:00:00:c9:d1:a4:ec 20:00:00:00:c9:d1:a4:ec PM
fc3/9
102
0x010045 10:00:e0:07:1b:ce:58:62 20:00:e0:07:1b:ce:58:62 P
Total number of flogi = 2.
FLAGS:
A area FCID allocation
L loop device
V FDISC
D the wwn matches the default OUI list
O the wwn matches the configured OUI list
P allocation was done based on the persistency table
M indicates a VMID capable FCID
On the Cisco switch, you can run the following command to get the mapping between, the FCID and the VMID:
(config-if)# show vmis database
An output similar to the following is shown:
Total 1 entries
----------------------------------------------------------------------------INTERFACE
VSAN FCID
LOCAL VEID
GLOBAL VEID
----------------------------------------------------------------------------fc3/4
102
0x010025 0x01
50072573-386e-296a-0c27-4f3a4c3c88ea
Broadcom
DRVVM-UG126-100
92
Emulex Drivers for VMware ESXi User Guide
Appendix E: License Notices
E.1 OpenSSL Notice
This is a copy of the current LICENSE file inside the CVS repository.
LICENSE ISSUES
==============
The OpenSSL toolkit stays under a dual license, i.e. both the conditions of the OpenSSL License and the original SSLeay license
apply to the toolkit. See below for the actual license texts. Actually both licenses are BSD-style Open Source licenses. In case
of any license issues related to OpenSSL please contact openssl-core@openssl.org.
OpenSSL License
--------------/*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
====================================================================
Copyright (c) 1998-2011 The OpenSSL Project. All rights reserved.
Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions
are met:
1. Redistributions of source code must retain the above copyright
notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright
notice, this list of conditions and the following disclaimer in
the documentation and/or other materials provided with the
distribution.
3. All advertising materials mentioning features or use of this
software must display the following acknowledgment:
"This product includes software developed by the OpenSSL Project
for use in the OpenSSL Toolkit. (http://www.openssl.org/)"
4. The names "OpenSSL Toolkit" and "OpenSSL Project" must not be used to
endorse or promote products derived from this software without
prior written permission. For written permission, please contact
openssl-core@openssl.org.
5. Products derived from this software may not be called "OpenSSL"
nor may "OpenSSL" appear in their names without prior written
permission of the OpenSSL Project.
6. Redistributions of any form whatsoever must retain the following
acknowledgment:
"This product includes software developed by the OpenSSL Project
for use in the OpenSSL Toolkit (http://www.openssl.org/)"
THIS SOFTWARE IS PROVIDED BY THE OpenSSL PROJECT ``AS IS'' AND ANY
EXPRESSED OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE OpenSSL PROJECT OR
ITS CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED
OF THE POSSIBILITY OF SUCH DAMAGE.
====================================================================
This product includes cryptographic software written by Eric Young
(eay@cryptsoft.com). This product includes software written by Tim
Hudson (tjh@cryptsoft.com).
Broadcom
DRVVM-UG126-100
93
Emulex Drivers for VMware ESXi User Guide
*/
Original SSLeay License
----------------------/* Copyright (C) 1995-1998 Eric Young (eay@cryptsoft.com)
* All rights reserved.
*
* This package is an SSL implementation written
* by Eric Young (eay@cryptsoft.com).
* The implementation was written so as to conform with Netscapes SSL.
*
* This library is free for commercial and non-commercial use as long as
* the following conditions are aheared to. The following conditions
* apply to all code found in this distribution, be it the RC4, RSA,
* lhash, DES, etc., code; not just the SSL code. The SSL documentation
* included with this distribution is covered by the same copyright terms
* except that the holder is Tim Hudson (tjh@cryptsoft.com).
*
* Copyright remains Eric Young's, and as such any Copyright notices in
* the code are not to be removed.
* If this package is used in a product, Eric Young should be given attribution
* as the author of the parts of the library used.
* This can be in the form of a textual message at program startup or
* in documentation (online or textual) provided with the package.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the copyright
*
notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
*
notice, this list of conditions and the following disclaimer in the
*
documentation and/or other materials provided with the distribution.
* 3. All advertising materials mentioning features or use of this software
*
must display the following acknowledgement:
*
"This product includes cryptographic software written by
*
Eric Young (eay@cryptsoft.com)"
*
The word 'cryptographic' can be left out if the rouines from the library
*
being used are not cryptographic related :-).
* 4. If you include any Windows specific code (or a derivative thereof) from
*
the apps directory (application code) you must include an acknowledgement:
*
"This product includes software written by Tim Hudson (tjh@cryptsoft.com)"
*
* THIS SOFTWARE IS PROVIDED BY ERIC YOUNG ``AS IS'' AND
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
* SUCH DAMAGE.
*
* The licence and distribution terms for any publically available version or
* derivative of this code cannot be changed. i.e. this code cannot simply be
* copied and put under another distribution licence
* [including the GNU Public Licence.]
*/
Broadcom
DRVVM-UG126-100
94
Was this manual useful for you? yes no
Thank you for your participation!