AMX MXT-1901-PAN is a powerful and versatile touch panel that offers a wide range of features and capabilities. With its sleek design and intuitive interface, the MXT-1901-PAN is perfect for controlling a variety of devices and systems in your home or office. Some of the features that make the MXT-1901-PAN stand out from other similar devices include its large 19-inch display, its built-in camera and microphone, and its support for a variety of wired and wireless connectivity options. Whether you're looking to control your home theater system, your lighting, or your security system, the MXT-1901-PAN is a great choice.
advertisement
CONF IGURATION & PROGRAMMING MANUAL
MODERO X
®
SERIES G5 TOUCH PANELS
MODERO X
MXR-1001
® SERIES G5 RETRACTABLE TOUCH PANEL:
MODERO X ® SERIES G5 TOUCH PANELS:
MXT/D-2001-PAN
MXT/D-1901-PAN
MXT/D-1001
MXT/D-701
IMPORTANT SAFETY INSTRUCTIONS
1.
READ these instructions.
2.
KEEP these instructions.
3.
HEED all warnings.
4.
FOLLOW all instructions.
5.
DO NOT use this apparatus near water.
6.
CLEAN ONLY with dry cloth.
7.
DO NOT block any ventilation openings. Install in accordance with the manufacturer's instructions.
8.
DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9.
DO NOT defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. ONLY USE attachments/accessories specified by the manufacturer.
12. USE ONLY with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. UNPLUG this apparatus during lightning storms or when unused for long periods of time.
14. REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. DO NOT expose this apparatus to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the apparatus.
16. To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle.
17. Where the mains plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
18. DO NOT overload wall outlets or extension cords beyond their rated capacity as this can cause electric shock or fire.
The exclamation point, within an equilateral triangle, is intended to alert the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the product.
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electrical shock to persons.
ESD Warning: The icon to the left indicates text regarding potential danger associated with the discharge of static electricity from an outside source (such as human hands) into an integrated circuit, often resulting in damage to the circuit.
WARNING: To reduce the risk of fire or electrical shock, do not expose this apparatus to rain or moisture.
WARNING: No naked flame sources - such as candles - should be placed on the product.
WARNING: Equipment shall be connected to a MAINS socket outlet with a protective earthing connection.
WARNING: To reduce the risk of electric shock, grounding of the center pin of this plug must be maintained.
COPYRIGHT NOTICE
AMX© 2017, all rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of AMX. Copyright protection claimed extends to AMX hardware and software and includes all forms and matters copyrightable material and information now allowed by statutory or judicial law or herein after granted, including without limitation, material generated from the software programs which are displayed on the screen such as icons, screen display looks, etc. Reproduction or disassembly of embodied computer programs or algorithms is expressly prohibited.
LIABILITY NOTICE
No patent liability is assumed with respect to the use of information contained herein. While every precaution has been taken in the preparation of this publication, AMX assumes no responsibility for error or omissions. No liability is assumed for damages resulting from the use of the information contained herein. Further, this publication and features described herein are subject to change without notice.
AMX WARRANTY AND RETURN POLICY
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
Table of Contents
Table of Contents
Modero X Series G5 Configuration & Programming .......................................14
MXR-1001 Retractable Touch Panels .............................................................16
Settings Menu .................................................................................................20
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 3
Table of Contents
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 4
Table of Contents
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 5
Table of Contents
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 6
Table of Contents
Using Content Sharing ....................................................................................78
Gestures ..........................................................................................................82
MXA-MP and MXA-MPL Programming .............................................................84
Programming - Send Commands ....................................................................87
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 7
Table of Contents
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 8
Table of Contents
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 9
Table of Contents
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 10
Table of Contents
Streaming Video, MXA-MP, and MXA-MPL Commands ................................................ 156
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 11
Table of Contents
SSH Commands ............................................................................................ 170
Appendix A: Upgrading Firmware via NetLinx Studio .................................. 179
Overview ....................................................................................................................... 179
NetLinx Studio 4 ........................................................................................................... 179
Upgrading Firmware via NetLinx Studio (v4 or Higher)............................................... 179
HTTP Server Transfer Error ................................................................................................................ 181
Appendix B: Using NetLinx to Define a Data Source (Listview Buttons) .......182
Example Listview Workflow - NetLinx Data Source ...................................................... 182
1) Create the Listview Button and Set Button Properties .................................................................. 182
List View Components ......................................................................................................................................................... 183
Item Height.......................................................................................................................................................................... 184
List View Columns................................................................................................................................................................ 184
List View Item Layout .......................................................................................................................................................... 184
Primary Partition (%).......................................................................................................................................................... 184
Secondary Partition (%) ..................................................................................................................................................... 184
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 12
Table of Contents
2) Create the Data Source .................................................................................................................. 185
Filter Enabled....................................................................................................................................................................... 185
Filter Height ......................................................................................................................................................................... 185
Alphabet Scrollbar............................................................................................................................................................... 185
Dynamic Data Source .......................................................................................................................................................... 185
NetLinx Usage Example - ASCII ....................................................................................................................... 186
3) Configure the Response to a User Selection.................................................................................. 188
Appendix C: Text Formatting ........................................................................189
Appendix D: Bargraph Functions ..................................................................193
Appendix E: Video Streaming ....................................................................... 194
Streaming a Video File Saved on the Panel via Custom URL Scheme.......................... 194
NMX-ENC H.264 Encoder - Encoder Settings for G5 Panels ........................................ 197
Appendix F: DragDrop.axi .............................................................................198
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 13
Modero X Series G5 Configuration & Programming
Modero X Series G5 Configuration & Programming
Overview
The Modero X ® Series G5 line of touch panels is the next generation in touch panel design, control and functionality. Each Modero
X Series G5 touch panel shares basic programming functionality with the other G5 products, whether a tabletop, portrait, or landscape panel. In order to assist programmers and developers with designing the perfect project, each Modero X Series G5 touch panel shares the following features:
A common arrangement of Settings pages that allow easy configuration of new panels into a new or existing network (see the
Settings Menu section on page 20).
Mutual NetLinx programming commands for the panel gestures supported by the Modero X Series G5 product line
Mutual NetLinx programming commands for other touch panel functions (see the
Programming - Send Commands section on page 87).
Ability to support applications (apps), such as a web browser or Skype, to enhance the functionality of the control surface
For more information on designing touch panel pages that optimize the Modero X Series G5 experience, please refer to the
TPDesign5 Instruction Manual and the G5 Considerations Guide , both available at www.amx.com
.
The Modero X Series G5 touch panels covered in this document are listed below:
Modero X Series G5 Touch Panels
MXT-2001-PAN
MXD-2001-PAN-P/L
FG5968-35 20.3" Modero X Series G5 Panoramic Tabletop Touch Panel
FG5968-36/37 20.3" Modero X Series G5 Panoramic Wall Mount Touch Panel - Portrait/Landscape
MXT-1901-PAN
MXD-1901-PAN-P/L
MXT-1001
MXD-1001-P/L
FG5968-41 19.4" Modero X Series G5 Panoramic Tabletop Touch Panel
FG5968-42/43 19.4" Modero X Series G5 Wall Touch Panel - Portrait/Landscape
FG5968-47 10.1" Modero X Series G5 Tabletop Touch Panel
FG5968-48/49 10.1" Modero X Series G5 Wall Panel - Portrait/Landscape
MXT-701
MXD-701-P/L
FG5968-53 7" Modero X Series G5 Tabletop Touch Panel
FG5968-54/55 7" Modero X Series G5 Wall Touch Panel - Portrait/Landscape
Also covered in this document is the MXR-1001 10.1" Modero X Series G5 Retractable Touch Panel. The MXR-1001 / 10.1" Modero X Series
G5 Retractable Touch Panel can be mounted within the table such that it is flush with the table when not in use. The motorized mount raises and retracts the panel with the press of a button or via NetLinx control:
MXR-1001-BL/SL FG5968-56/57 10.1" Modero X Series G5 Retractable Touch Panel - Black/Silver
NOTE: The MXR-1001 Modero X Series G5 Retractable Touch Panels have several features that are specific to raising and lowering
the panel. Refer to the MXR-1001 Retractable Touch Panels section on page 16 for details.
Transitioning from G4 to G5
The G5 platform is a new operating system for Modero X Series touch panels. Existing TPDesign4 files are not compatible with G5 touch panels. TPDesign5 is required to design touch panel files for G5 systems, and is available for download at www.amx.com
.
NOTE: For information on Configuring and Programming X Series G4 touch panels, refer to the Modero G4 Configuration and
Programming Guide (available at www.amx.com).
TPDesign5 is similar in look and feel to TPDesign4 and can be installed concurrently with TPDesign4 to enable the developer to design for both G4 and G5 systems at the same time. TPDesign5 also contains a utility called G4Utility , that converts existing TPD4 files to TPD5-formatted files.
While G4Utility converts the bulk of a TPD4 file to a format usable in TPD5. Some tweaking of the converted TPD5 file may still be necessary afterwards.
NOTE: For more information on transitioning from the G4 platform to G5, please refer to the AMX G5 Considerations white paper, available at www.amx.com.
Using the "Pipe" ( | ) Character
Previously, in G4, the pipe character ( |) was used to create a new line.
G5 uses carriage return / line feed ($0d,$0a) instead.
The examples below illustrate indicating a new line (between the words "Hello" and "World") in G4 and in G5 programming:
G4 : "'^TXT-200,0,Hello | World'"
G5 : "'^TXT-200,0,Hello', $0d,$0a ,'World'"
Touch Panel Aspect Ratio
While the touch panel screen physical dimensions fall between 16:9 and 16:10, any incoming video stream can be scaled to 16:9 if needed. This may lead to some letter boxing around the video in some cases.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 14
Modero X Series G5 Configuration & Programming
Active Video Windows - Limitations
The term "Active Video Windows" refers to any "window" on the touch panel (which could be a Page, Popup, Sub-Page or Button) that is displaying active video content.
Maximum supported number of active video windows displayed simultaneously on the panel: 2
While this limitation is not enforced (i.e the TPDesign5 application will allow you include any number of video windows in the panel design), attempting to display more than two active video windows at one time may have a negative impact on the panel’s overall performance.
Maximum supported resolution for video windows: 720dpi
Maximum supported frame rate for video windows: 30fps
Additional Documentation
For instructions on using NetLinx Studio, refer to NetLinx Studio online help, or the NetLinx Studio v4 Instruction Manual .
For instructions on using TPDesign5, refer to TPDesign5 online help, or the TPDesign5 Instruction Manual .
For installation instructions for Modero X Series panels, refer to the Modero X
Hardware Reference Guide .
For MXR-1001 installation instructions, refer to the MXR-1001 Modero X and Hardware Reference Guide .
® Series G5 Touch Panels Installation and
® Series G5 Retractable Touch Panel Installation
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 15
MXR-1001 Retractable Touch Panels
MXR-1001 Retractable Touch Panels
Overview
The MXR-1001 10.1" Modero X ® of a button or via NetLinx control.
Series G5 Retractable Touch Panel is a 10.1" Modero X G5 Touch Panel that can be mounted within the table such that it is flush with the table when not in use. A motorized mount raises and retracts the panel with the press
Sleep/Settings pushbutton
Up/Down
Pushbutton/LED
FIG. 1 MXR-1001 (Lowered and Raised)
MXR-1001 Motor Controller
The MXR-1001features the same hardware components and provides all of the functionality of the standard MXD-1001 10.1"
Modero X G5 Touch Panel. The primary distinguishing feature of the MXR-1001 is the ability to raise and retract the touch panel.
Therefore, there are electrical and firmware features specific to the MXR-1001 that provide control of the motorized mount. The
MXR-1001 Motor Controller reports the physical state of the motor and panel to the NetLinx Master.
Powering On/Off the MXR-1001 Touch Panel
MXR-1001 touch panels may be powered on by touching the Sleep/Settings pushbutton (just like other G5 touch panels). The
Sleep/Settings pushbutton is located in the in the center of the top panel of the touch panel (FIG. 2):
Sleep/Settings pushbutton
FIG. 2 MXR-1001-BL Sleep/Settings Pushbutton
The MXR-1001 also supports power-up via PoE signaling, but note that PoE is not a power supply option for the MXR-1001.
To power off the panel, press and hold the button to invoke the on-screen menu, and select Power Off (FIG. 3):
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 16
MXR-1001 Retractable Touch Panels
Press to power off the panel
Press to access the Settings menu
FIG. 3 On-screen menu Power Off/Settings options
If the device has gone into its Sleep mode, touching the touchscreen or pressing the Sleep button will reactivate it.
Press and hold the Sleep button to access the Settings menu.
NOTE: Powering off the touch panel does not remove power to the motor. To completely remove power from the motor and touch panel, unplug the power cable (located on the Motor Mount).
Raising and Lowering the MXR-1001 Touch Panel
Press the external pushbutton (with LED) to raise and lower the touch panel on the MXR-1001.
When the MXR-1001 is closed, press the
pushbutton to raise the panel
When the MXR-1001 is open, press the
pushbutton to lower the panel
FIG. 4 Up/Down pushbutton
The brightness of the pushbutton LED can be adjusted via the ^MCC Send Command (LEDBRIGHTNESS subcommand). The panel can be raised and lowered via the (MOTOR subcommand). Refer to the Modero X® Series G5 Touch Panels
Configuration & Programming Manual for details
Warning Screen
When the touch panel is in motion (raising or lowering), a warning screen is displayed on the panel (FIG. 5):
FIG. 5 MXR-1001 Warning: Panel In motion. Keep clear of opening.
NOTE: If the Up/Down pushbutton is pressed while the panel is in motion, the panel will reverse direction.
Some touch panel components are automatically disabled when the panel is in the Lowered position - see the Modero X®
Series G5 Touch Panels Configuration & Programming Manual for details.
Application windows that are open when the panel is in motion are automatically closed. Popup windows will stay opened after the panel is completely raised and the warning message (FIG. 5) is closed.
The pushbutton can be used to raise/lower the panel even if the MXR-1001 is not connected to a Master (for example during installation), as long as the MXR-1001 is powered.
Audio Alert
The Audio Alert feature allows the MXR-1001 to play a sound when the panel is raised, and/or a separate sound when the panel is lowered. The Panel Lower Sound and Panel Raise Sound settings can be configured under the "Sound" Settings menu (see
page 28). Note that by default, the
Panel Raise sound is set to "None".
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 17
MXR-1001 Retractable Touch Panels
Locking and Unlocking the MXR-1001
By default, the panel is unlocked. When the panel is locked, the Pushbutton (see FIG. 1) is disabled.
When the MXR-1001 is unlocked, press the pushbutton to raise or lower the panel.
When the MXR-1001 is locked, the pushbutton is disabled until authentication credentials are verified. When locked, button presses are sent to the Master for potential action via NetLinx code. If the panel drops offline while locked, the panel can only be raised or lowered via the Motor SSH command. Note that if High Security Mode is enabled, SSH functionality will not
be available. See the SYSTEM - Security section on page 60 for details on security mode settings.
MXR-1001 Send Commands
"'^MCC-<MOTOR|LOCK|AUTHENTICATION|LED>’" Motor Controller Control/Configure . This command uses multiple
sub-commands to configure Motor, Lock, Authentication and LED settings. See page 161 for details.
"'?POS-<id>'" - Panel Position Query . Requests the current position of the panel. A new custom event (custom event type
1602) reports the status of the Motor Controller, including its state and whether or not the lock feature is on. This event is sent either in reply to the “?POS” query, or unsolicited to report a status change. It is also sent when the panel first comes
online to report initial status. See page 162 for details.
Motor Controller State Reporting
The Motor Controller reports the following potential states of the motor/panel:
Motor Controller State Reports
State
ERROR
RAISED
LOWERED
Criteria
An error has occurred and the panel’s position may be indeterminate.
Panel is fully up in its raised position
Panel is fully retracted in its lowered position
RAISING
LOWERING
Panel is ascending from the table.
Panel is lowering back into the table.
STALLED-RAISING Panel has stalled while raising, and is somewhere between its lowest and highest position.
STALLED-LOWERING Panel has stalled while lowering, and is somewhere between its lowest and highest position.
STALLED-UNKNOWN Panel has stalled, and it is unknown whether it was in the process of raising or lowering (it is somewhere between its lowest and highest position).
RAISE-PENDING A request to raise the panel has been received via a press on the external pushbutton, but the panel is locked (authentication is required prior to acting on the request).
LOWER-PENDING A request to lower the panel has been received via a press on the external pushbutton, but the panel is locked (and authentication is required prior to acting on the request).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 18
MXR-1001 Retractable Touch Panels
MXR-1001 Motor Controller State Table
Depending on the current State (as reported by the Motor Controller), certain panel components are either enabled (ON) or disabled (OFF), as described in the following table:
Panel Component Behavior For Each Panel State
Motor
State
ERROR
RAISED
LOWERED
RAISING
LOWERING
Panel Components
No action taken on state change (let NetLinx code determine handling)
Backlight Touch
HID Input
(mouse, keyboard)
VNC Mic
Proximity/
Light
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON ON ON OFF ON OFF*
On
(Warning message appears)
On
(Warning message appears)
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
STALLED -
RAISING
STALLED -
LOWERING
STALLED -
UNKNOWN
RAISE
PENDING
LOWER
PENDING
ON
ON
ON
OFF*
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
* except when VNC active
Speaker
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Bluetooth
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
SIP
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
MXR-1001 Motor Controller LED Behavior
The Up/Down pushbutton on the MXR-1001 features a blue LED that provides feedback on the Motor Controller (FIG. 1). The table below describes the feedback for various scenarios.
Motor Controller LED Behavior
Condition or Fault LED Pattern
Panel in Motion (either raising or lowering), regardless of how it was initiated Slow blink
Authorization failure (either timeout or denial)
Any fault reported by the motor controller
Communication failure between panel and Motor Controller
Button press
When Cleared
When motion stops
Fast blink - 3 seconds After 3 seconds
Fast blink Until fault clears
Fast blink When communication is restored
Momentary feedback Upon button release
NOTE: If the LED On brightness is set to 0, no feedback will be visible. LED On/Off brightness settings are configured via the ^MCC
Send Command (see page 161 for details).
Configuration and Programming
MXR-1001 touch panels are equipped with a Settings menu that provides the ability to configure various features on the panels. To access the Settings menu, press and hold the Sleep button, and select Settings. This opens the main Settings menu.
The MXR-1001 Settings menu is similar to the Settings menu on other X Series G5 touch panels. The main differences are:
Removal of NFC functionality and related options in the Settings menu.
Removal of Camera functionality and related options in the Settings menu.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 19
Settings Menu
Settings Menu
Overview
G5 panels present all configuration information via the on-board Settings menu. The DEVICE , CONNECTIONS , ACCOUNTS , and
SYSTEM sections are password-protected. The default password is 1988 .
Accessing the Settings Menu
To access the Settings menu, press and hold the Sleep/Settings button on the panel for 3 seconds.
Sleep button
FIG. 6 Accessing the Setting menu
If the Sleep/Settings Button Has Been Disabled
Access to the Settings menu via the Sleep/Settings button can be disabled via the Front Button Access option in the Security page
(see the
SYSTEM - Security section on page 60 for details). Note that the
Front Button Access option is disabled automatically if the panel is in High Security Mode. When the Sleep/Settings button is disabled, there are other ways to access the Settings Menu:
Press and Hold the Sleep/Settings Button During Bootup
When the panel is booting up (for example, after a reboot or power cycle), wait for the Modero X Series logo to be displayed on the panel, then press and hold the Sleep/Settings button to open the Settings menu.
Note that if the panel was in High Security mode when it was rebooted, then it remains in High Security mode when it boots back up. In High Security Mode, access to the Settings menu is limited to non-protected pages only. In this case, the current High
Complexity password is requiconnector bayred to access protected setup pages.
See the
Via the "G5:setup" SSH Command (Standard Security mode only)
Use the "G5:setup" SSH command to launch the Settings menu.
Syntax:
G5:setup [options]
Options
--help
Display this help message
Refer to the SSH Commands section on page 170 for details on all SSH commands.
NOTE:
for details on security mode settings.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 20
Settings Menu
Using AMX System Recovery
During a normal firmware upgrade, if a G5 panel is unable to boot all the way, AMX System Recovery can be used to try to reset system data or re-install firmware. To initiate system recovery:
1.
Power up the panel while holding the Sleep/Settings button.
2.
Release the button 3 seconds after seeing the AMX boot logo, and wait a few seconds for recovery mode to begin.
3.
A text screen titled "AMX System Recovery" is displayed, presenting the following options:
Reboot Device
Factory Data Reset
Revert to Factory Firmware
Install Firmware from USB
4.
Navigate the menu options by pressing the Sleep/Settings button.
To select an item, press and hold the Sleep/Settings button for 2 or more seconds. Alternatively, if the panel has a USB keyboard plugged in at bootup, use the Up/Down arrows and Enter keys to navigate the menus.
Select Reboot Device to reboot the panel.
Select Factory Data Reset and then select Yes on the confirmation window to erase all of the user data (settings, application data, user pages) on the panel.
Select Revert to Factory Firmware and then select Yes on the confirmation window for the system to extract the factory firmware (this can take a minute) and then automatically initiate a firmware upgrade as usual.
Select Install Firmware from USB for a new menu to come up, where the user can navigate the files on the USB drive.
Selecting the "../" entry will take the user back to the previous directory. Entries with a trailing "/" on the name are directories, and selecting a directory will bring up a new menu with the contents of that directory shown. All other entries will be ".kit" files. Selecting a KIT file and selecting Yes on the confirmation screen will extract the firmware (this can take a minute) and then automatically initiate a firmware upgrade as usual.
Using the Settings Menu
When opened, the Settings menu appears in the center of the panel display. Please note that many of the pages in the menu may be longer than they initially appear. To reach additional functions on a given page, the page itself may be scrolled up and down to reveal those functions.
NOTE: The Settings menu uses scrolling lists. Not all items on a Settings page are visible on screen at one time, and scrolling up and down to see them may be necessary. In the case of long Settings pages, a scroll bar appears momentarily when a new menu appears, and allows you to gauge current position and length of the menu.
Many of the entries in the Settings menu are read-only. Information on the Device Info page (the initial view) will update when modified on subsequent pages.
The current information on a page appears in white under the main category title; press the text to open the category’s page
connectivity (connecting a USB stick to the panel, for instance) or changes to other pages within the menu.
FIG. 7 Settings Menu - Default View (INFO > Device Info)
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 21
Settings Menu
Settings Pages - G5 Menu Bar Options
The following functions are available in the G5 Menu Bar displayed at the bottom of all pages in the Settings window:
Settings Pages - G5 Menu Bar Options
Encryption:
Connection:
Maximize/Minimize:
The Encryption (Key) icon in the upper-right corner of the Settings application window indicates whether the panel is currently using an Encrypted ICSP connection to communicate with the NetLinx Master:
• Red = no encryption
• Green = Encrypted ICSP Connection detected
The Connection icon in the upper-right corner of the Settings application window indicates the current connection status of the panel:
• Red = no connection
• Green = connected to the Master
Select this to maximize or minimize the size of the Settings menu window on the display.
Volume: Press to open the Volume window and adjust the output volume on the panel:
Return to Previous Menu: Press the arrow to return to the previous menu.
Close Settings App: Press the “X” button to shut the Settings menu and return to the main display.
Adjust Window Size: Hold and drag the corner to adjust the size of the Settings menu window.
Settings Pages - Application Specific Options
Several of the applications available on G5 panels have application-specific options that are not controlled by the panel. For example, the Image View
features of the application, but since they are not G5-specific features (and therefore not controlled by the panel), they are not described in this document.
FIG. 8 G5 Settings Page Controls vs Application-Specific Features
Settings Menu - Page Categories
The main Settings
categories: INFO , DEVICE , CONNECTIONS , ACCOUNTS , and SYSTEM. The menu options available via the Settings window are summarized below:
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 22
Settings Menu
Settings Menu options
Page Name
INFO (initial view)
Device Info
Maintenance
DEVICE
Storage
Description
Displays basic panel information, such as available memory and screen resolution dimensions.
Provides control of basic panel functions, including rebooting or shutting down the panel.
Sound
Display
G5 Settings
Camera
Sensors
VNC
Content Sharing
SIP
CONNECTIONS
Ethernet
NetLinx
Browser
Multi Preview
Bluetooth
NFC
Smart Card
Provides access to data stored on the panel, as well as files accessible via connected USB storage devices.
Allows adjustment of volume levels and panel sounds settings.
Note: For MXR-1001 retractable panels, these include Panel Raise and Panel Lower sounds.
Provides controls for basic functions of the panel display, including brightness.
Provides controls for page flip tracking and configuring Sleep mode.
Provides control of the panel’s built-in camera.
Allows activation and optimization of the panel’s motion and light sensors.
Enables/disables and configures VNC server functionality on the panel.
Allows G5 touch panels to share content on Enzo meeting room presentation systems.
Allows configuration of SIP communication settings for the panel.
Allows configuration of Ethernet communication settings with the panel.
Controls the method of connecting to a NetLinx Master.
Sets the default view mode for URLs opened in a Browser window.
Configures the panel to receive signals from MXA-MP or MXA-MPL devices for video stream display.
Provides the ability to pair one or more Bluetooth devices to the panel. Bluetooth functionality is only available if an (optional) MXA-BT Bluetooth USB Adapter (FG5968-19) is connected to the panel.
Controls the panel’s Near Field Communications™ access, and displays the last NFC tag read by the panel.
Note: This option is not available on MXR-1001 retractable panels.
Enables Smart Card functionality on the panel, and provides access to the PIV Authentication
Certificate and CHUID associated with the Smart Card reader.
ACCOUNTS
Add Account Provides the ability to configure outside accounts (such as Email and Dropbox) so that they can be used on the panel.
SYSTEM
Date & Time
Security
Allows setting and adjusting of time and date information on the panel.
Language & Input Controls the language used by the Settings menu, as well as the keyboard input used for Settings menu field entries.
Controls panel security, including setting the security profile to either Standard or High Security, password settings, enabling/disabling device functionality on the panel, enabling/disabling system services, and front button access.
Reset and Update Allows resetting and updating of panel settings and firmware, including installation of new firmware from an external drive.
Diagnostics Displays the current processor temperature, provides access to panel logs, and toggles SSH functionality.
Page #
All of the pages and menus in the Device , Connections , Accounts , and System categories are password-protected.
Opening Settings pages
1.
Select the appropriate page from the Settings menu.
2.
In the Password keypad, enter the password and select OK . The default password is 1988 .
Closing the Settings menu
To close the Settings menu and return to the panel’s user pages, select the Close Settings App icon at the bottom of the Settings window.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 23
Settings Menu
INFO - Device Info
The INFO - Device Info
(read-only).
Scroll down to see all menu items
FIG. 9 INFO - Device Info page
Device Info page options
DEVICE
Device IP
Device Number
Device Name
Device Type
Serial Number
Version
MAC Address
Bluetooth Address
Resolution
NETLINX MASTER
Master IP
Master Port
Master System Number
Connection
MEMORY AND FILES
Memory
File System
File Information
MISC
Up Time
Legal Information
Displays the panel’s IP address.
Displays the panel’s device number.
Displays the panel’s device name.
Displays the panel model.
Displays the specific serial number value assigned to the panel.
Displays the current version of the panel’s firmware.
Displays the panel’s MAC address.
Displays the panel’s Bluetooth address.
Displays the panel’s screen height and width in pixels.
Displays the IP address for the panel’s Master.
Displays the port used by the panel’s Master.
Displays the Master’s system number.
Displays the panel’s connection status.
Displays the amount of memory available on the panel.
Displays the amount of MicroSD card memory available on the panel.
Displays information on the current main panel page.
Displays the time elapsed since the panel was last started.
Select this entry to open the Legal Information window, which displays information on intellectual property notices and information on copyright concerns.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 24
Settings Menu
INFO - Maintenance
The INFO - Maintenance
FIG. 10 Maintenance page
INFO - Maintenance page options
Reboot:
Shutdown:
Select this entry to open the Reboot window.
Select this entry to open the Shutdown window.
Rebooting the Panel
1.
In the Maintenance page, select Reboot . This opens the Reboot
FIG. 11 Reboot window
2.
Press OK to reboot.
Shutting Down the Panel
1.
In the Maintenance page. select Shutdown . This opens the Shutdown
FIG. 12 Shutdown window
2.
Press OK to shut down the panel.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 25
Settings Menu
DEVICE - Storage
NOTE: The DEVICE pages are all password-protected. The default password is 1988.
The Storage
This page also displays files accessible via connected USB storage devices, such as from hard drives or thumb drives.
Scroll down to see all menu items
FIG. 13 Storage page
Storage page options
INTERNAL STORAGE
Internal Storage
Total Space
Available
Apps (app data & media content)
Pictures, Videos
Audio (music, ringtones, podcasts, etc.)
Downloads
Cached Data
This graph displays how much internal storage is being used compared to what is available, and which file categories are using that storage. Note that this graph is color-coded to indicate how much storage is being used by each storage type (described below).
The total amount of storage space on the panel.
The total amount of storage that may be used for apps and other files on the panel.
The total amount of storage currently being used for apps and related files on the panel. Note that Apps are installed via TPDesign5, and cannot be added or removed via the panel.
The total amount of storage currently being used for picture and video files on the panel.
The total amount of storage currently being used for audio files (such as music, ring tones, and podcasts) on the panel. Select this entry to open the Choose Music Track window. See the
Audio section on page 27 for details.
The total amount of storage currently being used for downloaded files (such as text files or spreadsheets) on the panel. Select this entry to open the Downloads window. See the
Internal Storage: Downloads section on page 27 for details.
The total amount of storage currently being used for cached data on the panel. Select this entry to clear the cache. See the
Internal Storage: Cached Data section on page 27 for details.
USB STORAGE
Mount USB Storage
USB Storage Graph
Total Space
Available
Unmount Shared
Storage
This option only appears if no USB data storage is connected to the panel.
This graph displays the total used storage in a connected USB storage device versus the total amount available. This graph only appears if a USB storage device is connected to the panel.
The total amount of used storage on the connected USB storage device.
The total amount of available storage on the connected USB storage device.
Select this option to allow safe removal of any USB data storage device connected to the panel.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 26
Settings Menu
Internal Storage: Audio
To access all audio files stored on the panel or stored in an individual Dropbox account, select Audio on the Storage page to open the Audio Access Options
FIG. 14 Audio Access Options
Choose the location of the file: Select Choose Music Track if the file is accessible via internal storage or USB; select Dropbox if the file is accessible via a Dropbox account.
NOTE: Before attempting to access a file on a Dropbox account, you must first open the Dropbox application on the panel and log in.
After selecting the option, either select Always to access files in this way every time the Audio option is selected, or select Just once to give both options every time.
Internal Storage: Downloads
From the Storage page, select Downloads to display all files downloaded to the panel. This opens the Downloads window. Select a downloaded file in the window to open it.
To close the Downloads window, touch the display screen anywhere outside of the window.
Internal Storage: Cached Data
Under Internal Storage , the Cached Data option indicates the amount of data currently in the panel’s memory cache for all applications.
To clear the cache, press Cached Data
. The panel will prompt you to verify this action before clearing the cache (FIG. 15):
FIG. 15 Clear Cached Data prompt
Select Cancel to return to the Storage page, or select OK to clear the cached data for all applications on the panel.
USB Storage
In addition to its internal storage capabilities, G5 panels also have the ability to access files in USB-enabled external storage options, such as thumb drives and external hard drives. The status of USB storage is indicated in the USB STORAGE section of the
Storage page.
If no USB storage option is connected to the panel, this section will read " Insert USB storage for mounting ".
If a USB storage option is connected to the panel, the USB Storage section will display the panel’s total used space and
total available space, as well as give the option to unmount the storage device (FIG. 16).
FIG. 16 USB Storage
Unmounting a USB Storage Device
1.
On the Storage page, select the Unmount Shared Storage option .
2.
This opens the Unmount USB storage?
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 27
Settings Menu
FIG. 17 Unmount USB Storage prompt
3.
Select OK to unmount the storage device (or Cancel to return to the Storage page).
If the storage device has been unmounted from the panel but is still physically connected, the only option in the USB Storage section will be Mount USB storage . Press this option to remount the storage device to the panel.
DEVICE - Sound
The Sound
page (FIG. 18) allows adjustment of volume levels and panel sounds settings.
Scroll down to see all menu items
FIG. 18 DEVICE - Sound page
Sound page options
Volumes Press to open the Volumes window, which provides options to adjust volume for Music, video, games and
DEVICE SOUNDS
Button Hit Sound
Button Miss Sound
Panel Lower Sound Select
(MXR-1001 only)
Displays the information on the sound file associated with the Button Hit Sound function. See the
Device Sounds section on page 30 for details.
Displays the information on the sound file associated with the Button Miss Sound function. See the
Selecting Device Sounds section on page 30 for details.
Play Test
NFC Sound Select
Select this entry to test the audio output by playing a preselected sound.
Sounds section on page 30 for details. Also see the
CONNECTIONS - NFC section on page 53.
Note : This option is not available on MXR-1001 retractable panels.
Smart Card Sound Select Select to choose a sound to associated with the smart card action from the menu provided (default = none ).
See Selecting a Default Notification Sound section on page 31.
Panel Raise Sound Select
(MXR-1001 only)
Displays the information on the sound file associated with the Panel Raise function.
The available sounds include all Button Hit and Button Miss sounds.
Note: By default, the Raise sound is set to "None" (the sound is disabled).
See the Selecting a Panel Raise and Lower Sound (MXR-1001 only) section on page 29 for details.
Displays the information on the sound file associated with the Panel Lower function.
The available sounds include all Button Hit, Button Miss and NFC Notifications Sounds.
Note: By default, the Lower sound is set to "None" (the sound is disabled).
See the Selecting a Panel Raise and Lower Sound (MXR-1001 only) section on page 29 for details.
SYSTEM SOUNDS
Touch Sounds
Default Notification
Sound:
Audio:
Select this entry to enable a notification sound every time the panel display is touched.
Select this entry to choose a default notification sound from the menu provided. See
Notification Sound section on page 31.
Displays the current audio options. The current and only option is "Internal Audio".
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 28
Settings Menu
Selecting a Panel Raise and Lower Sound (MXR-1001 only)
The MXR-1001 10.1" Modero X Series G5 Retractable Touch Panel provides two additional Sound options that allow you to specify the sound played to indicate that the panel is raised and lowered.
1.
In the Sound page:
Select Panel Raise Sound Select to select a sound to coincide with the retractable panel being raised via the Panel Raise
Sound Select
Select Panel Lower Sound Select to select a sound to coincide with the retractable panel being lowered via the Panel Lower
Sound Select
FIG. 19 Panel Raise Sound Select and Panel Lower Sound Select windows
2.
Choose a sound from the presented list: selecting a new sound will play it once. The sound will only be audible if the Media slide bar in Volumes is not muted.
3.
Once you select the preferred sound, press OK to save it. The sound’s name will now appear under the category in the Sound page.
4.
If you wish to return to the Sound page without making any changes, press Cancel .
NOTE: The sound will play regardless of the state that the panel was in prior to transitioning to the Lowering or Raising states.
For example, if the panel is in a Stalled state and the user attempts to lower the panel, the "Panel Lower Sound" will play. If the Master does not authorize the requested operation, the panel will not transition and so the alert sound will not be played.
Adjusting Volumes
1.
In the Sound page, select the Volume
Music Volumes
control window (FIG. 21 on page 30):
FIG. 20 DEVICE - Sound page - Volume Control icon
2.
This opens the Music Volume control. Use this slider to adjust the volume for music tracks. To mute music playback, move the slider all the way to the left. In this case, the volume icon on the Music Volume control will indicate Muted .
3.
Press the icon on the right side of the Music Volume control to open the System Volumes control. Use these volume controls to
adjust all of the available volume controls on the panel (FIG. 21):
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 29
Settings Menu
Music Volume control
System Volume controls
Music/media volume
Call volume (during a call)
Notifications volume (including Skype ringtone)
Alarm volume
FIG. 21 Music Volume control and System Volumes control
To adjust the panel’s media volume, slide the Music/media slide bar pointer to your preferred level. To mute the panel, move the slidebar pointer all the way to the left. The speaker icon on the left of the slidebar will indicate that the panel is muted.
To adjust the volume of notifications, slide the Notifications slide bar pointer to your preferred level. If the Music/media slide bar is set to mute, the Notifications slide bar will also be muted.
To adjust the volume of alarms, slide the Alarms slide bar pointer to your preferred level. The Alarms volume will NOT be muted if the other slide bars are set to mute.
Selecting Device Sounds
Use the options under DEVICE SOUNDS in the Sound Settings page to select a particular sound to coincide with a button being
pressed in a panel page (FIG. 22):
FIG. 22 Device Sounds - Button Hit Sound / Button Miss Sound Selection
1.
In the Sound page,
Select Button Hit Sound to select a sound to coincide with a button being pressed via the Button Hit Sound window.
Select Button Miss Sound to select a sound to coincide with a button being missed via the Button Miss Sound window.
Press Play Test to play a sample sound file to test the volume setting.
Select NFC Sound Select to select a sound to coincide with an NFC device being detected by the panel via the NFC Sound
Select window.
NOTE: NFC functionality is not available on MXR-1001 retractable panels.
Select Smart Card Sound Select to select a sound to coincide with a Smart Card being detected by the panel via the Smart
Card Sound Select window.
FIG. 23 Device Sounds - NFC Sound Select / Smart Card Sound Select
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 30
Settings Menu
Select Panel Raise/Lower Sound Select to select sounds to coincide with raising or lowering the retractable touch panel
(MXR-1001 only).
2.
Choose a sound from the presented list: selecting a new sound will play it once. The sound will only be audible if the Media slide bar in Volumes is not muted.
3.
Once you select the preferred sound, press OK to save it. The sound’s name will now appear under the category in the Sound page.
4.
To the Sound page without making any changes, press Cancel .
Selecting a Default Notification Sound
To select a particular sound to be the default notification sound for all panel functions:
1.
In the Sound page, under SYSTEM SOUNDS, enable the Touch Sounds option.
2.
Select Default notification sound . This opens the Default notification sound window.
3.
Choose a sound from the presented list: selecting a new sound will play it once. The sound will only be audible if the
Notifications slide bar in Volumes is not muted.
4.
Once you select the preferred sound, press OK to save it. If you wish to return to the Sound page without making any changes, press Cancel .
DEVICE - Display
The Display
page (FIG. 24) controls the basic functions of the panel display, including the panel brightness.
FIG. 24 DEVICE - Display page
Display page options
Brightness:
Display Timeout: Indicates the length of time that the panel can remain idle before the display automatically powers down. Select the
Display Timeout setting. Range = 15, 30 seconds, 1, 5, 10, 30 minutes, 1, 2 hours. Set the timeout value to None to
disable Display Timeout mode. See the Adjusting Display Timeout on page 32 for details.
Font Size: Sets the size of the font used in the Settings menu. See
Selecting the Font Size on page 32 for details.
Calibration Test: Select this to open the Calibration Test page. See
Calibration Test on page 32 for details.
Adjusting Panel Brightness
In the Display page, select Brightness to open the Brightness window (FIG. 25).
FIG. 25 Brightness window
Use the slidebar for manual adjustment of the panel’s display brightness. Select Automatic brightness to make automatic adjustments to brightness based on ambient light in the vicinity. Press OK to save changes and close this window (or select Cancel to return to the Display page without saving any changes).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 31
Adjusting Display Timeout
In the Display page, select Display Timeout to open the Display Timeout
Settings Menu
FIG. 26 Display Timeout menu
Select the time period that will pass before the panel enters sleep mode, or select None to keep the panel from shutting down its display. The default settings is 30 Minutes .
Press OK to save changes and close this window (or select Cancel to return to the Display page without saving any changes).
Selecting the Font Size
In the Display page, select Font size to open the Font Size
FIG. 27 Font Size menu
Select the desired size for the font used in the Settings menu via this window. The default setting is Normal .
Changing this setting requires re-entry of the password in order to confirm your changes. If you wish to return to the Display page without saving any changes, select Cancel at the bottom of the window.
Calibration Test
Select Calibration Test to open the Calibration Test page (FIG. 28):
FIG. 28 Calibration Test menu
G5 panels are self-calibrated on startup. The Calibration Test page may be used to verify the accuracy of that calibration.
NOTE: In order to ensure a correct calibration upon starting, the panel display should not be touched while the panel is booting.
To run a calibration test on the touch panel:
1.
In the Settings menu, select Display .
2.
In the Display page, select Calibration Test .
3.
Touch the screen to test the calibration.
4.
For options when testing the calibration of the touch panel, select Options to open the Calibration Test Options window
Press Fade to cause the cursor to fade away after touching, or press it again to retain all touches on the display screen.
Press Clear to clear the memory of previous touches. When finished, select Exit to return to the Calibration Test page.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 32
Settings Menu
FIG. 29 Calibration Test Options window
5.
When finished with the calibration test, select Exit to return to the Display page.
DEVICE - G5 Settings
The G5 Settings
duration before going into Sleep mode.
Scroll down to see all menu items
FIG. 30 G5 Settings page
G5 Settings page options
Page Tracking
Function Show
Press to enable or disable the panel sending page flip tracking to the Master. Default = disabled.
Press to display the address, channel, and level information associated with each button on the panel.
Default = disabled.
Verbose File Diagnostics Press to display file error dialogs any time the panel encounters a problematic file. Default = disabled.
REMOTE PROFILE
Remote Profile Press On to enable Remote Profiles. Note that turning Remote Profiles On enables the Remote URL option (see note below).
Remote URL Enter the URL of the desired remote profile: press this field to access an on-screen keyboard. Refer to
Setting a Remote Profile section on page 33 for details.
INACTIVITY
Inactivity:
Inactivity Page:
Select this to open the Inactivity window and control the maximum time the panel will remain inactive before going into Sleep mode. Refer to
Setting an Inactivity Time Period and Page Flip section on page 34 for details.
Lists the TPDesign5 page displayed when the panel goes to sleep. Refer to
Setting an Inactivity Time Period and
Page Flip section on page 34 for details.
PASSWORD PROTECTION
Password 1-4
These options provide the option of assigning passwords to the secured Settings pages. Refer to
Password Protection section on page 34 for details.
HTTPS CLIENT
Validate HTTPS Server
Certificate
Verify HTTPS Server
Hostname
Press to enable or disable the validation of HTTPS server certificate while negotiating the connection.
Default = disabled.
Press to enable or disable the verification of the HTTPS Server hostname. Note that this option is available only if the Validate HTTPS Server Certificate option is selected. Default = disabled.
Setting a Remote Profile
NOTE: Enabling a Remote Profile will cause the panel to ignore and TP5 file that has been transferred to the panel. It will only open the TP5 file set in the Remote URL.
1.
In the G5 Settings page, press Remote Profile to toggle the option ON .
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 33
2.
Press Remote URL
to enter the URL of the remote profile to use via the on-screen keyboard (FIG. 31):
Settings Menu
FIG. 31 Remote URL window
3.
Press OK to save changes and close this window.
Setting an Inactivity Time Period and Page Flip
1.
In the G5 Settings page, press Inactivity to open the Inactivity
FIG. 32 Inactivity window
2.
Select the amount time that will be allowed to pass before the panel enters into sleep mode. Select Off to disable the inactivity timer. The default setting is 1 hour .
Setting Password Protection
FIG. 33 G5 Settings page - PASSWORD PROTECTION options (Password 1-4)
1.
In the G5 Settings page, under PASSWORD PROTECTION , press Password 1 to open the Password 1 window to enter a new
alphanumeric password via the on-screen keyboard (FIG. 34):
FIG. 34 Password 1 window
2.
Press OK to save changes (or press Cancel to close this window without saving changes).
3.
Press Password 2 , Password 3 and Password 4 to set Passwords 2-4 (press OK to save each).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 34
DEVICE - Camera
The Camera
page (FIG. 35) controls the output from the panel’s built-in camera.
Settings Menu
FIG. 35 Camera page
Camera page options
Streaming Video Opens the Streaming Video window.
NOTE: When the camera is enabled, an LED next to the camera lights (on the front panel) to indicate that it is on.
Streaming Video
The Streaming Video window (FIG. 36) is used to preview video sources, as well as preview input from the panel’s camera.
FIG. 36 Streaming Video window
The Streaming Video page may also be used to preview other video sources, (i.e. MXA-MP or MXA-MPL)
Streaming Video Page options
Enter URL: Select this to enter the URL for the video stream to be displayed.
The default is the panel’s camera, if applicable.
Clear URL: Select this to clear the current streaming video URL being displayed.
Entering a Streaming Video URL
To enter a URL for a remote video stream source:
1.
From the Streaming Video page, select Enter URL to open the Enter URL window
FIG. 37 Enter URL window
2.
Enter the URL for the video feed and press OK .
3.
If the feed format is supported and visible, the video feed will now appear in the Streaming Video page window.
Clearing the Current Streaming Video URL
Press Clear URL in the Streaming Video window to clear the current URL for a remote streaming video source.
To close the Streaming Video window, touch anywhere outside of the window.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 35
DEVICE - Sensors
The Sensors
page (FIG. 38) allows activation and optimization of the panel’s motion and light sensors.
Settings Menu
Scroll down to see all menu items
FIG. 38 Sensors page
Sensors page options
Motion Detection
Wake on Motion Sense:
Wake on Motion Test:
Light Sensor Level Value
Light Sensor Calibration:
Light Sensor Level Port:
Light Sensor Level Number:
Light Sensor Channel Port:
Light Sensor Channel Number:
Motion Sensor Channel Port:
Motion Sensor Channel Number:
Sensor Version:
• The blue bar within the slide bar shows the current motion sensor reading.
• The slide bar sets the motion sensor threshold.The threshold controls when a motion sensor channel is on.
• The “walk” icon shows bars on either side when the threshold is crossed (FIG. 38).
Press this checkbox to wake up the panel if any motion detected crosses the threshold set by the
Motion Detection slide bar.
This selection only be enabled if Wake Panel On Motion Sense is enabled.
Pressing the test button will initiate a test mode where the display will go to sleep and wait for motion to turn it on. It can be used to test your current Motion Detection threshold value.
• The blue bar within the slide bar displays the current light sensor reading.
• The slide bar indicates the light sensor threshold.
• The threshold controls when a Light Sensor Channel Code press will be generated.
Displays the current level port being used by the light sensor (read-only). Default = 1.
Displays the current level being used by the light sensor (read-only). Default = 0.
Displays the current channel port being used by the light sensor (read-only). Default = 1.
Displays the current channel being used by the light sensor (read-only). Default = 0.
Displays the current channel port being used by the motion sensor (read-only). Default = 1.
Displays the current channel being used by the motion sensor (read-only). Default = 0.
Displays the current sensor version (read-only).
NOTE: Light and motion sensor ports, levels, and channels are configured in TPDesign 5. For more information on configuring light and motion sensors, please refer to the TPDesign 5 Operation/Reference Guide , available at www.amx.com.
Calibrating the Light Sensor
When the panel is installed for the first time, the light sensor should be calibrated to the room’s maximum ambient light condition.
This calibration setting will be saved until the panel’s system settings are reset.
To calibrate the light sensor from the Settings pages:
1.
From the Sensor Settings page, press Light Sensor Calibration .
2.
Allow the panel 10 seconds to calibrate the room's ambient light level. The indicator next to the button will show a rotating circle while calibration is in progress.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 36
Settings Menu
DEVICE - VNC
An on-board VNC (Virtual Network Computing) server allows the panel to connect to any remote PC running a VNC client. Once connected, the client can view and control the panel remotely. The options on the VNC
page (FIG. 39) allow you to enable or disable
VNC server functionality on the panel.
FIG. 39 VNC page
VNC page options
Enable/Disable: The Enable/Disable button toggles between the two VNC settings:
• Disable - deactivates the VNC server on the panel.
• Enable - activates the VNC server on the panel (default setting).
Timeout:
Password:
Port:
Sets the length of time (in minutes) that the panel can remain idle, detecting no cursor movements, before the
VNC session is terminated. (default = 15 minutes ).
Enter the VNC Authentication session password required for VNC access to the panel.
Use this field to enter the number of the port used by the VNC Web Server. Note that this field is enabled only while VNC is disabled (default = 5900 ).
Current Connections: Displays the number of users currently connected to this panel via VNC (read-only).
Maximum
Connections:
Displays the maximum number of users that can be simultaneously connected to this panel via VNC. Press this field to increase the number allowed to connect to this panel. (default = 2 ).
NOTE: The VNC server takes snapshots of the display buffer and sends them via VNC at a low frame rate.
Enabling VNC
In the VNC page, press Enable/Disable to toggle VNC to ON (the default setting is OFF).
Configuring VNC Access
In the VNC page, use the options under VNC SERVER to configure various aspects of VNC access on the panel:
Press Timeout to specify a timeout period for VNC connections, in the Timeout window. Press OK to save changes.
Press Password to assign the password to be required to establish a VNC connection, in the Password window. By default, no VNC password is set. Press OK to save changes.
Press Port to specify the port to be used by the VNC Web Server, in the Port window. This option is not available if VNC is currently enabled. Press OK to save changes.
Press Maximum Connections to set the maximum number of users that can be simultaneously connected to this panel via
VNC. Press OK to save changes.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 37
Settings Menu
DEVICE - Content Sharing
The Content Sharing application allows G5 touch panels to share (display) content on Enzo meeting room presentation systems.
With Content Sharing enabled, G5 touch panel users can connect to an Enzo unit to share content from USB, Dropbox, or other downloads.
NOTE: Content Sharing considers the G5 touch panel to be the "Sender" of content, and Enzo units are considered to be "Receivers" of the shared content.
The options on the Content Sharing
page (FIG. 40) allow you to enable Content Sharing functionality on the panel, as well as
configure one or more Enzo units as receivers of shared content.
FIG. 40 Content Sharing page
Enabling Content Sharing on the Panel
In the Content Sharing page, press Enable/Disable to toggle Content Sharing to ON (the default setting is OFF).
Note that when Enable is set to ON , the Configure Receivers option is activated.
Configuring the Receivers List
In the Content Sharing page, press Configure Receivers to invoke the Configure Receivers Options
FIG. 41 Content Sharing page - Configure Receivers Options window
This window presents two options for adding Enzo receivers to the Receiver List for the panel:
Add Receiver : Use this option to add an Enzo receiver by manually entering the target Enzo’s device Name, IP/Hostname,
Port and Username/Password (if the target Enzo has security enabled). See page 39 for details.
Scan For Receivers: Use this option to scan the local network for Enzo receivers. Use this option when you know that there is at least one Enzo present on the network. You don’t have to know the target Enzo’s IP information, but if security is enabled on the Enzo, you will need to enter the Username and Password required to connect.
Scanning the Network for Enzo Units
Use the Scan for Receivers option to automatically detect Enzo units that are on the same subnet as the panel.
NOTE: In order to use the Scan for Receivers option, the target Enzo unit(s) must have Auto Discovery enabled (which is the default setting). Refer to the Enzo Instruction Manual for details on configuring Enzo units for use with Content Sharing.
1.
In the Content Sharing page - Configure Receivers Options
window (see FIG. 41 on page 38), press
Scan for Receivers . This initiates a scan of the local network for Enzo units.
2.
As Enzo units are discovered, they are added to the DISCOVERED RECEIVERS
FIG. 42 Configure Receiver window - DISCOVERED RECEIVERS list indicating one Enzo receiver
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 38
Settings Menu
NOTE: As Enzo units are discovered. they are listed in order in which they are discovered. Each Enzo unit is represented in this list by it’s current device name (as set on the Enzo unit). If the device name has not been edited, then the default device name is used, as
shown in FIG. 42. The default device name is based on the unit’s serial number.
3.
Press to select an Enzo unit to use as the receiver for Content Sharing functions on this panel. This invokes the Configure
Receiver
FIG. 43 Configure Receiver window - indicating connection information for the selected Enzo Receiver
4.
Review the connection information presented n this window, and edit if necessary. Also, enter the Username and Password required to connect to the selected Enzo receiver (if applicable).
5.
Press OK to save changes and close the Configure Receiver window and on-screen keyboard.
6.
Press the back button in the G5 Menu Bar to return to the main Content Sharing page. The Enzo receiver should now appear in the RECEIVER LIST
FIG. 44 RECEIVER LIST - Send Message icon
7.
To test the connection, press the Share Content icon in the RECEIVER LIST to send a test message to the Enzo unit. If the Enzo
FIG. 45 Enzo - Successful Test Message
Manually Adding an Enzo to the Receivers List
Use this method if the Enzo unit is on a different subnet than the G5 panel. This method requires that you know the IP Address of the Enzo unit.
1.
In the Content Sharing page - Configure Receivers Options
Add Receiver . This invokes the Configure
Receiver window and on-screen keyboard.
2.
Use the on-screen keyboard to enter all required information for the target Enzo receiver. The information entered must match the connection information on the target Enzo unit (as it appears on the Enzo’s Settings > About page):
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 39
Settings Menu
Receiver Name (required)
IP/Hostname (required)
Port (required)
Username/Password (if required by the Enzo unit)
FIG. 46 Configure Receiver window with sample entries for an Enzo receiver
3.
Press OK to save changes and close the Configure Receiver window and on-screen keyboard. The Enzo receiver should now appear in the RECEIVER LIST
FIG. 47 RECEIVER LIST - Send Message icon
4.
The Enzo receiver should now appear in the RECEIVER LIST .
5.
To test the connection, press the Send Message icon in the RECEIVER LIST to send a test message to the Enzo unit. If the Enzo
FIG. 48 Enzo - Successful Test Message
Using Content Sharing
Enzo units.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 40
Settings Menu
DEVICE - SIP
G5 panels are available to participate in G4 intercom operations. This includes point to point, and point to multi-point sessions
using the standard ^ICS , ^ICM, and ^ICE commands (page 142).
Videocom is not available at this time. Skype should be used for video communications.
No configuration is necessary for intercom operation. All configuration is done via Send Commands.
The SIP
page (FIG. 49) controls the configuration of settings for SIP communication with the panel.
FIG. 49 SIP page
SIP page options
Enable/Disable Controls connection to the SIP server: When enabled, the panel will attempt to connect to the provide IP address.
SIP will automatically be disabled if the panel is unable to connect to the gateway.
SIP Server Address Enter the IP address of the SIP gateway in this text field.
Domain
Name
Password
Port
Codec
DTMF Duration
Enter the domain name of the SIP Server.
Enter the Username/extension for this panel.
Enter the User defined password for this user/extension.
Enter the IP port to communicate over (default = 5060 ).
Specify the codec to use for SIP communication: u-law or A-law (default = u-law ).
Specify the duration of DTMF
Configuring the Panel for use with a SIP Server
Use the options on the SIP page to configure the panel to communicate with a SIP server (FIG. 50):
FIG. 50 SIP page - SIP configuration options
NOTE: The SIP configuration options described below are only enabled for editing if SIP is disabled (via the Enable/Disable option at the top of the SIP page).
1.
In the SIP Options
SIP Server Address to enter the IP address of the SIP Server in the SIP Server Address window. Press OK to save changes and close the SIP Server Address window.
2.
Press Domain to enter the domain name of the SIP Server in the Domain window. Press OK to save changes and close this window.
3.
Press Name to enter the name of the SIP Server in the Name window. Press OK to save changes and close this window.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 41
Settings Menu
4.
Press Password to enter the password required to connect to the SIP Server in the Password window. Press OK to save changes and close this window.
The default port number for SIP communications is 5060 . If it is necessary to change the SIP port number assignment, press Port to open the Port window. Enter the desired port number and press OK to save changes and close this window.
G5 panels support both u-law and A-law codecs. The default codec used by the panel for SIP communications is u-law . If it is necessary to switch codecs, press Codec and select A-law in the Codec window. Press OK to save changes and close this window.
The default DTMF duration setting (the length of time in milliseconds to play each digit) is 100 . If it is necessary to adjust this value, press DTMF Duration and enter the desired duration (in msecs) in the DTMF Duration window. Press OK to save changes and close this window.
Enabling SIP Functionality on the Panel
One the panel has been configured to communicate with the SIP Server, SIP functionality must be enabled on the panel. Press
Enable Disable to toggle SIP functionality to enabled . The Enable/Disable switch indicates ON
FIG. 51 SIP page - SIP Enabled
Custom Ringtones & Ringback Tones
G5 supports custom ringtones and ringback tones:
Customizing the Ringtone
The default incoming call ringtone can be overridden by including a wave file named " ringtone.wav
" in the TP5 project file.
If a " ringtone.wav
" file is found in the TP5 file, it is used instead of the default ringtone. If no such file exists, then the default ringtone is used.
Customizing the Ringtone For Particular Caller Numbers
A custom ringtone can be configured for calls from a specific extension by including a wave file named " ringer_xxxx.wav
" file in the TP5 project file. For example, a file named " ringer_6001.wav
" would be used as a custom ringtone for incoming calls from extension 6001 .
This will override the custom ringtone.wav
for any extension that has a custom ringer_xxxx.wav sound defined.
Customize Ringback Tone
Te default ringback tone (for an outgoing call) can be overridden by placing a " ringback.wav
" file in the TP5 project file.
NOTE: Ringtones set in the contacts app are not used by G5 at this time.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 42
CONNECTIONS - Ethernet
The Ethernet
page (FIG. 52) controls the configuration of settings for Ethernet communication with the panel.
Settings Menu
Scroll down to see all menu items
FIG. 52 Ethernet page
Ethernet page - IPV4 tab options
DHCP/Static:
IP Address:
Subnet Mask:
Sets the panel to either DHCP or Static communication modes.
• DHCP is an IP Address assigned to the panel by a DHCP server. If DHCP is selected, the other Network Connection fields are disabled (see below).
• Static IP is a permanent IP Address assigned to the panel. If Static IP is selected, the other Network Connection fields are enabled.
Displays the IP address for this panel. If DHCP is enabled, this field will be disabled.
Displays the subnetwork for this panel. If DHCP is enabled, this field will be disabled
Gateway:
Hostname:
Domain:
Primary DNS:
Displays the gateway address for this panel. If DHCP is enabled, this field will be disabled.
Displays the hostname for this panel.
Displays a name to the panel for DNS look-up. If DHCP is enabled, this field will be disabled.
Displays the address of the primary DNS server used by this panel for host name lookups. If DHCP is enabled, this field will be disabled.
Secondary DNS: Displays the secondary DNS address for this panel. If DHCP is enabled, this field will be disabled.
MAC Address: This unique address identifies the Ethernet connection in the panel (read-only).
802.1x Security Displays the current state (disabled or enabled) of 8021.x security (default = disabled ). Press to set enable and configure 802.1x security on the panel via the 802.x1 Security
Ethernet page - IPV6 tab options
IPv6 Support When enabled, the panel will attempt to connect via IPv6 (default = OFF ). To enable IPv6 support on this panel, press to toggle this setting to ON. Note that when IPv6 Support is On, the following fields are enabled for editing:
Specifies the static IPv6 address for this panel.
Static IPv6
Address
Static IPv6
Subnet Prefix
Length
Static IPv6
Gateway
Specifies the Static IPv6 Subnet Prefix Length for this panel.
Specifies the Static IPv6 Gateway address for this panel.
Displays the Link Local IP address for this panel, if one exists (read-only).
Link Local IP
Address:
Neighbor
Discovery IP
Address:
Discovered IPv6
Gateway:
Hostname:
Domain:
Primary DNS:
Displays the Neighbor Discovery IP address for this panel (read-only).
Displays the Discovered IPv6 gateway for this panel (read-only).
Displays the hostname for this panel.
Displays a name to the panel for DNS look-up.
Displays the address of the primary DNS server used by this panel for host name lookups.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 43
Settings Menu
Ethernet page - IPV6 tab options (Cont.)
Secondary DNS: Displays the secondary DNS address for this panel.
MAC Address: This unique address identifies the Ethernet connection in the panel (read-only).
802.1x Security Displays the current state (disabled or enabled) of 802.1x security (default = disabled ). Press to set enable and configure 802.1x security on the panel via the 802.x1 Security
Setting Static IP Information (IPv4)
When using DHCP settings for a panel, the DHCP server will automatically populate almost all of the Ethernet page fields, with the exception of Hostname . When setting the panel for Static , however, all IP address information must be entered manually:
1.
Press DHCP/Static to access the DHCP/Static options window (FIG. 53):
FIG. 53 DHCP/Static window
2.
Press Static to open the Static IP (IPv4)
FIG. 54 Static IP (IPv4) window
3.
Press any field in this window to open the on-screen keypad or keyboard.
4.
Enter IP address information for each field presented, via the Static IP window.
5.
When complete, press OK to save changes and return to the Ethernet page - IPV4
FIG. 55 Ethernet page (IPV4 tab) - indicating Static IP connection information
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 44
Settings Menu
Entering a New Hostname (IPv4/DHCP only)
In order to facilitate DNS lookup of the panel, you should set a new hostname for the panel. To add a new hostname, or to change an existing one:
1.
From the Ethernet page (IPv4 tab), select Hostname to open the Hostname window (FIG. 56).
FIG. 56 Hostname window
2.
Enter the new hostname and press OK .
The new hostname will now appear in the Hostname field.
Setting IPv6 Information
When using IPv6 network addressing for a panel, IPv6 support must be enabled on the panel, and all IP address information must be entered manually:
1.
In the Ethernet page, open the IPV6
FIG. 57 Ethernet page - IPV6 tab
2.
Toggle the IPv6 Support option ON
. Note that this enables the other fields for editing (FIG. 58): :
FIG. 58 Ethernet page - IPV6 tab (IPv6 support enabled)
3.
Press the Static IPv6 Address field to set the static IP address for this panel, via the Static IP
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 45
Settings Menu
FIG. 59 Static IP (IPv6) window
4.
Press Static IPv6 Address to enter this information via the on-screen keypad or keyboard. Press OK to save changes and return to the Ethernet page (IPV6 tab).
5.
Repeat for the Static IPv6 Subnet Prefix Length, Static IPv6 Gateway, Hostname, Domain, Primary and Secondary DNS fields.
6.
When complete, press OK to save changes and return to the Ethernet page - IPV6
FIG. 60 Ethernet page (IPV6 tab)
Working With 802.1x Security
Use the 802.1x Security option in the Ethernet page (both tabs) to enable and configure 802.1x security settings on this panel:
1.
From the Ethernet page (either tab), select 802.1x Security to open the 802.1x Security
FIG. 61 802.1x Security window (OFF)
2.
Toggle this feature ON
to enable the editable fields in this window (FIG. 62):
3.
Press User certificate to select a user certificate to use for 802.1x access.
4.
Press User certificate to select a user certificate to use for 802.1x access
5.
Press the Identity and Password fields to enter the appropriate Identity and Password for 802.1x access via the on-screen keyboard.
6.
Press OK to save changes and return to the Ethernet page.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 46
Settings Menu
FIG. 62 802.1x Security window (ON)
CONNECTIONS - NetLinx
The NetLinx
page (FIG. 63) controls the method of connecting to a NetLinx Master.
Scroll down to see all menu items
FIG. 63 NetLinx page
NetLinx page options
Scan for Masters
Mode
Press to scan for NetLinx masters on the network, via the Master Connection
window. See Scanning for Masters on page 48 for details.
Cycles between the connection modes: URL , Listen , and Auto .
• URL - Enter the IP/URL, Master Port Number, and username/password (if used) on the Master. The System
Number field is read-only - the panel obtains this information from the Master.
• Listen - Add the panel address into the URL List in NetLinx Studio and set the connection mode to Listen. This mode allows the panel to “listen” for the Master’s communication signals. The System Number and Master IP/
URL fields are read-only.
• Auto - Enter the System Number and a username/password (if applicable). Use this mode when both the panel and the NetLinx Master are on the same Subnet.
The Master IP/URL field is read-only.
System Number
Master IP/URL
Allows entry of a system number. Default value is 0 (zero).
Note: Available in Auto Mode Only - disabled when URL or Listen is selected.
Sets the Master IP or URL of the NetLinx Master.
Note: Available in URL Only - disabled when Listen or Auto is selected .
Master/Port Number Allows entry of the port number used with the NetLinx Master. Default = 1319.
Username If the target Master has been previously secured, enter the alpha-numeric string (into each field) assigned to a preconfigured user profile on the Master.
This profile should have the predefined level of access/configuration rights.
Password
Device Number
Device Name
If the target Master has been previously secured, enter the alpha-numeric string (into each field) assigned to a preconfigured user profile on the Master.
This profile should have the predefined level of access/configuration rights.
Displays the panel’s device number and allows entry of a new one.
Displays the panel’s device name and allows entry of a new one.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 47
Settings Menu
NetLinx page options (Cont.)
Secure Master
Connection
Press to enable and configure a connection a secured NetLinx Master, via options in the NetLinx window (see
Note: The secure connection is a TLS connection to a NetLinx Master on port 1320.
Note: This option is only available if the Secure Master Connection option is enabled.
Connection Status Displays the panel’s connection status to the Master.
Scanning for Masters
Use the Scan For Masters feature to quickly and easily identify all of the available NetLinx Masters on the network.
The site survey on this page passively listens to network traffic and presents all the compatible Masters for easy selection.
Selecting the desired Master automatically updates the NetLinx Master section and establishes a connection.
1.
In the NetLinx page, press Scan For Masters to begin listening for NetLinx masters and open the Master Connection window
Scroll down to see all menu items
FIG. 64 Master Connection window
2.
Select the NetLinx Master for this panel.
3.
The NetLinx page will automatically display the connection information on the selected Master.
Changing the Master Connection Mode
To select the Master Connection mode ( URL , Listen , or Auto ):
1.
In the NetLinx page, press Mode
to open NetLinx Options window (FIG. 65):
FIG. 65 NetLinx Options window - Mode menu
2.
Select the desired option from the Mode menu - URL (default setting), Listen or Auto .
3.
When finished, press OK to return to the NetLinx page.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 48
Changing the Master IP/URL
To change the IP address or URL for the chosen Master:
1.
In the NetLinx page, press Master IP/URL to open the NetLinx Options window and on-screen keyboard.
2.
Enter the IP address or the URL.
3.
Press the double-down arrow key at the bottom right of the on-screen keyboard to close the keyboard.
4.
The new IP address/URL is now displayed in the Master IP/URL field.
5.
Press OK to save the changes and return to the NetLinx page.
Changing the Master Port Number
To change the Master Port Number from its default:
1.
In the NetLinx page, press Master Port Number to open the NetLinx Options window and on-screen keyboard.
2.
Enter the new Master Port Number.
3.
Press the double-down arrow key at the bottom right of the on-screen keyboard to close the keyboard.
4.
The new Port Number is now displayed in the Master Port Number field.
5.
Press OK to save the changes and return to the NetLinx page.
Changing the Master Username
1.
In the NetLinx page, press the Username field to open the NetLinx Options window and on-screen keyboard.
2.
Enter the new username.
3.
Press the double-down arrow key at the bottom right of the on-screen keyboard to close the keyboard.
4.
The new Username is now displayed in the Username field.
5.
Press OK to save the changes and return to the NetLinx page.
Changing the Master Password
1.
In the NetLinx page, press Password to open the NetLinx Options window and on-screen keyboard.
2.
Enter the new password.
3.
Press the double-down arrow key at the bottom right of the on-screen keyboard to close the keyboard.
4.
The new Password is now displayed in the Password field.
5.
Press OK to close the NetLinx window and return to the NetLinx page.
Changing the Device Number and Device Name
1.
In the NetLinx page, press the Device Number field to open the NetLinx Options window and on-screen keypad.
2.
Enter a new Device Number.
3.
Press Next , to select Device Name in the NetLinx page and open the n-screen keyboard.
4.
Enter a new Device Name.
5.
Press Done to close the keypad and keyboard.
6.
The new Device Number and Device Name are now displayed in the Device Number and Device Name fields.
7.
Press OK to save changes and close the NetLinx window and return to the NetLinx page.
Enabling a Secure Master Connection
1.
In the NetLinx page, press the Secure Master Connection field to open the NetLinx Options window.
2.
Scroll to the bottom of the options list and toggle the Secure Master Connection option ON
Settings Menu
FIG. 66 NetLinx Options window - Secure Master Connections and Hostname Verification options enabled
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 49
Enabling Hostname Verification
1.
In the NetLinx page, press the Hostname Verification field to open the NetLinx Options window.
2.
Scroll to the bottom of the options list and toggle the Hostname Verification option ON
Settings Menu
FIG. 67 NetLinx Options window - Secure Master Connections and Hostname Verification options enabled
Note that this option is available only if the Secure Master Connection option is ON.
CONNECTIONS - Browser
Use TPDesign5 to add "application windows" to the panel. There are many different types of application windows that can be added to the panel file. One of them is "Browser", which opens a web browser window on the panel.
NOTE: Refer to the TPDesign5 online help for details on adding Application Windows to your touch panel project.
The options in the Browser
page of the Settings menu (FIG. 68) allow you to specify the
default view mode for specific URLs, when they are opened in a "Browser" application window. The view mode options are "desktop" and "mobile", and the default mode is
"mobile".
FIG. 68 Browser page
Browser page options
Add a URL Select to add a URL to the URL list. This selection opens the Enter URL
window (FIG. 69). Enter the URL and de-select the
Use desktop version option to request 'mobile' content for the URL. By default, this option is selected.
URLs This list provides the ability to request either 'desktop' or 'mobile' content for each URL in the list This selection is made when a URL is added to the list (see below).
Adding a URL to the URLs List
1.
From the Browser page, press Add a URL
to open the Enter URL
2.
Enter the URL in the text field.
3.
By default, the Use desktop content option is selected; de-select this option to request 'mobile' content for the URL.
4.
Press OK to close the Enter URL window and return to the Browser page. The new URL is indicated in the URLs list.
Once a URL has been added to the URLs list, the view mode setting ( desktop or mobile ) for that website can be specified:
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 50
Settings Menu
FIG. 69 Enter URL window
Switching Between Desktop and Mobile Content
content setting is indicated beneath each URL in the list (FIG. 70):
FIG. 70 URL list - desktop / mobile content
Deleting a URL from the URL’s List
Press the X icon to delete any URL from the list. Note that if a website that is not represented in the URLs list is opened on the panel, it will always open in the Mobile (default) view mode.
NOTE: Refer to the TPDesign5 online help for details on adding Application Windows (including Browser windows) to your touch panel project.
CONNECTIONS - Multi Preview
To use the MXA-MP Multi Preview or MXA-MPL Multi Preview Live devices for video stream display, the panel to which it is connected must be configured to receive its signals. If a Multi Preview device is not connected to the panel’s network, all fields but the Enable button will be empty.
Scroll down to see all menu items
FIG. 71 Multi Preview page
Multi Preview page options
Enable:
Version:
Press to enable the panel to receive information from the Multi Preview device.
Displays the current firmware version on the Multi Preview device.
Serial Number:
MAC Address:
Displays the serial number of the Multi Preview.
Displays the MAC address of the Multi Preview
Input Information: Displays the video format and resolution coming from the video input port.
Stream Information: This feature is currently disabled.
NOTE: For more information on operation and configuration of an MXA-MP or MXA-MPL, refer to the MXA-MP/MPL Instruction
Manual, available at www.amx.com.
Configuring the Panel To Accept Multi Preview Signals
1.
In the Multi Preview page, press the Enable button to enable the panel to receive information from the Multi Preview device.
2.
If a Multi Preview device is connected, the remaining information on the Multi Preview page will self-populate as the panel receives that information from the Multi Preview device.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 51
Settings Menu
NOTE: If the Multi Preview device is not connected to the panel, any attempts at enabling the device will fail, and the Multi Preview page will be blank other than the Enable button. If an MXA-MP or MPL is not connected to the panel, the Enable button MUST be disabled to prevent network conflicts.
CONNECTIONS - Bluetooth
The Bluetooth
page provides the ability to pair one or more Bluetooth devices to the panel (FIG. 72):
FIG. 72 Bluetooth page
NOTE: Bluetooth functionality is only available if an (optional) MXA-BT Bluetooth USB Adapter (FG5968-19) is connected to the panel.
To listen for Bluetooth devices:
1.
Press the Bluetooth
menu item to toggle the function ON (FIG. 73):
FIG. 73 Bluetooth page - Bluetooth Enabled
All Bluetooth devices detected are listed in the Bluetooth window.
2.
Press a device in the list to pair it with the panel.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 52
Settings Menu
CONNECTIONS - NFC
The NFC page controls the panel’s Near Field Communications™ (NFC) access, as well as displaying the last NFC tag read by the
FIG. 74 NFC page
NFC page options
Enable/Disable:
Last Tag Read:
Press to enable or disable NFC functionality.
Displays the last-read NFC tag ID.
NOTE: For more information on the NFC capabilities of your panel, please refer to the product documentation for the panel in question. All product documentation is available at www.amx.com.
NFC Commands
Custom Events for NFC
NFC Read tag custom event Reported to the master when the panel reads an NFC Tag.
Custom event type - 700
ID - 1
Flag - 0
Value1 - Tag Type
Value2 - Data Type
Value3 - Length of data in the Text field
Text - NFC Data (of type specified by Value2)
Where Tag Type is:
1 = ISO 15693
2 = ISO 14443A
3 = ISO 14443B
4 = FeliCa (currently not supported)
Data Type is:
0 = custom.text field contains the NFC UID (as a text string)
1 = custom.text contains NFC data (currently not supported)
Streaming video custom event Indicates streaming video status changes. Start and stop stream based events are sent to the master in the form of custom events.
The eventID 768 is sent to port 1 on the master.
The fields are:
CUSTOM.TYPE = EVENTID = 768
CUSTOM.ID = ADDRESS = 0
CUSTOM.FLAG = Start(1), Stop(2), Error(8)
CUSTOM.VALUE1 = Number of starts (or stops or errors)
CUSTOM.VALUE2 = Address of button/stream
CUSTOM.VALUE3 = Port of button/stream
CUSTOM.TEXT = stream URL
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 53
Settings Menu
CONNECTIONS - Smart Card
The Smart Card page enables Smart Card functionality on the panel, and provides access to the PIV Authentication Certificate and
CHUID associated with the Smart Card reader (FIG. 75).
FIG. 75 Smart Card page
Smart Card page options
Enable/Disable:
Reader Name
Press to toggle the smart card service on this panel (default = OFF).
This read-only field displays the name of the attached smart card reader, if a reader is attached and enabled.
Read PIV Authenticate Certificate Press to read and display the PIV Authentication Certificate of the smart card.
Read CHUID
Verify PIN
Press to read and display the CHUID from the smart card.
Press to require the entry of a valid PIN for the smart card.
ACCOUNTS - Add an Account
G5 panels allow access to outside accounts, such as corporate and personal Email, Skype and Dropbox. These must be configured through the Add an Account
section (FIG. 76) before they can be used with the panel.
FIG. 76 Add an account page
Adding an Account
1.
In the Settings menu, select Add an Account .
2.
In the Add an Account
window, select the type of account you wish to add to the panel (see FIG. 76).
3.
Follow the instructions in each window for each account (FIG. 77).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 54
Settings Menu
FIG. 77 Example account windows
NOTE: Entering an incorrect password on the panel for an Email account could result in locking that User’s account.
SYSTEM - Date & Time
The Date & Time
page (FIG. 78) allows setting and adjusting the time and date information on the panel.
Scroll down to see all menu items
FIG. 78 Date & Time page
Date & Time page options
Automatic Date & Time: When checked, the panel retrieves time/date information from a network time server (NTP). Default = Enabled .
Set network time server: Press this option to specify the IP address/name of a custom NTP if desired.
Set Date:
Set Time:
Use the
Use the
Set Date
Set Time
window (FIG. 79) to set the current day, month, and year.
window (FIG. 79) to select the current time.
Select Time Zone:
Use 24-Hour Format:
Choose Date Format:
Use the
Use the
Select Time Zone
When checked, this option always displays the time in 24-hour format.
Choose Date
window (FIG. 82) to select the current time zone.
Format window (FIG. 83) to select the desired date format.
The current date and time may be retrieved from NTP or it may be updated manually.
Retrieving the Date and Time From NTP
1.
In the Date & Time page, press Automatic Date & Time . Note that this option is selected by default.
2.
Make sure that the checkbox is selected.
3.
The date and time will be updated automatically by NTP.
Manually Setting the Date and Time
1.
If Automatic Date & Time is enabled, de-select the field to disable it.
2.
Press Set Date to open the Set Date window (FIG. 79).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 55
Settings Menu
FIG. 79 Set Date and Set Time windows
3.
Select the date, either by pressing and dragging on the fields on the left or by pressing the date in the calendar.
4.
Press Set Time to open the Set Time window
5.
Select the time by pressing and dragging on the fields in the center.
6.
Press Done to save changes and close this window.
Specifying a Network Time Server
If Automatic Date & Time is enabled, the network time server used can be specified via the Set network time server option:
1.
Press Set network time server to open the Set network time server window
FIG. 80 Set network time server window
2.
Press Custom to open the NTP Server
FIG. 81 NTP Server window
3.
Enter the IP address/name of the time server to use.
4.
Press OK to save changes and close this window.
Manually Setting the Time Zone
1.
Press Select Time Zone to open the Select Time Zone
Scroll down to see all menu items
FIG. 82 Select Time Zone window
2.
Select the time zone desired. The window will automatically close and return to the Date & Time page.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 56
Settings Menu
Specifying a Date Format
1.
Press Choose Date Format to open the Choose date format
FIG. 83 Choose Date Format window
2.
Select the desired date format. The window will automatically close and return to the Date & Time page.
SYSTEM - Language & Input
The Language & Input
page (FIG. 84) controls the language used by the
Settings menu, as well as the keyboard input used for
Settings menu field entries.
Scroll down to see all menu items
FIG. 84 Language & Input page
Language & Input page options
Language: Select a language for the Settings menu. See
Selecting the Panel’s Language on page 57 for details.
Spell Checker:
Personal Dictionary:
Enable this option to include an automatic spell checker in all Settings menu fields.
Lists all words saved in the panel’s personal dictionary file. See
Personal Dictionary on page 58 for details.
KEYBOARD & INPUT METHODS
Default: Specify the default system keyboard. Refer to
Changing Input Methods on page 58 for details.
System Keyboard: Choose the keyboard matching the selected panel language, or another language-format keyboard. Refer to
Changing Input Methods on page 58 for details.
PHYSICAL KEYBOARD
Generic: Selects the format for a physical keyboard connected to the panel.
Auto-Replace: Select this for automatic correction of commonly mistyped words.
Auto-Capitalization: Select this for automatic capitalization of the first word in a sentence.
Auto-Punctuate:
MOUSE/TRACKPAD
Select this for automatic addition of a period when the space key is pressed twice.
Pointer Speed:
Selecting the Panel’s Language
The default language for G5 panels is English , but this may be changed at any time through the Language & Input page:
1.
In the Language & Input page, press Language to open the Language
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 57
Settings Menu
Scroll down to see all menu items
FIG. 85 Language Selection window
2.
Choose a language from the list shown. To return to the default language without making any changes, select Language & input at the top of the window to close the window.
Personal Dictionary
Modero X Series G5 panels have automatic spell-checking capabilities, but additional regularly used words may be added to the panel’s personal dictionary. To add new words or phrases to the personal dictionary:
1.
In the Language & Input page, press Personal dictionary to open the Personal Dictionary
FIG. 86 Personal Dictionary window
2.
Press the Add button in the upper right hand corner of the page to open the Personal dictionary entry window.
3.
Press in the field beneath PHRASE to open the Personal Dictionary keyboard, and enter the word or phrase.
To add a shortcut for long or complex words, enter it in the Shortcut field.
If the word you add is in a language other than English, select the arrow in the lower right corner of the window to open the
Language menu. This gives you the option of adding the word to the English dictionary, a dictionary for a language other than English, or for use across all languages. The Language page will automatically close after the language is selected.
To delete a word or phrase, select it in the Personal dictionary window and then press Delete in the upper right hand corner of the Settings menu.
Changing Input Methods
While a standard English keyboard is the default input language, you may also change the input method, such as choosing a Dvorak keyboard. To change the keyboard layout:
1.
In the Language & Input page, under KEYBOARD & INPUT METHODS , press Default to open the Choose Input Method window
FIG. 87 Choose Input Method window
2.
Press Set up input methods to open the Keyboard Options
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 58
FIG. 88 Keyboard Options window
3.
Press the Settings icon next to System keyboard to access the System Keyboard Settings
Settings Menu
FIG. 89 System Keyboard Settings page
4.
Edit these settings as desired, and press the return icon to close this page and return to the Keyboard Options window.
5.
Under PHYSICAL KEYBOARD, press Generic to open the Choose Keyboard Layout
FIG. 90 Choose Keyboard Layout window
6.
Press Set up keyboard layouts to open the Keyboard Layout
FIG. 91 Keyboard Layout window
7.
Select the keyboard layouts that should be available for selection.
8.
Press the return icon to close the Keyboard Layouts window and open the Choose Keyboard Layout
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 59
Settings Menu
FIG. 92 Keyboard Layout window
9.
Select the desired layout.
Changing the Pointer Speed
1.
Under MOUSE/TRACKPAD, press Pointer Speed
to open the Pointer Speed window (FIG. 93):
FIG. 93 Pointer Speed window
2.
Use the slide bar to choose the preferred speed.
3.
Press OK to save changes and close this window.
SYSTEM - Security
G5 Panels support two security modes: Standard and High Security :
Standard is wide open and lets the administrator decide what is enabled/disabled.
High Security is targeted at max security installations. In High Security mode, everything that could be a remote threat is disabled and cannot be turned on.
The Security
Scroll down to see all menu items
FIG. 94 Security page
Security page options
SECURITY PROFILE
Enforce High Security
Profile:
Click to enable the high security profile on this panel. The panel will alert you if the current password does not meet the requirements for the currently selected Password Complexity setting (see Password Complexity below).
Note: If this option is switched from High Security back to standard security mode, all of the security values are set to default EXCEPT the password. The password remains unchanged from the complex password.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 60
Settings Menu
Security page options (Cont.)
PROTECTED ACCESS
Configuration
Protected:
Front Button Access:
Select this checkbox to protect the pages within the Settings menu from access without a password. By default, this option is selected.
• If the setting is selected, then a password will be required to access the Settings pages except Device Info and Maintenance .
• If this option is not selected, then there is no password protection on the panel, and all Settings pages are accessible to users.
Select this checkbox to enable or disable the ability to access the pages within the Settings menu from the
Sleep/Settings
Note: If Sleep/Settings button access is disabled, the Settings menu can be accessed through the splash page,
send command or a preconfigured setup button on panel pages.
PASSWORDS
Make Passwords Visible: Select this option to allow you to see the number of characters in a password, and to see, briefly, the character just typed in clear text for verification. If this option is not selected, then characters are not displayed in the password text input field.
Password Complexity: Select this option to set the level of Password Complexity to either STANDARD or HIGH (via the Password
Complexity dialog:
• STANDARD - There are no complexity rules for a STANDARD complexity password. In this case, the password can be any length, including empty, and there are no minimum requirements for characters in the password.
• HIGH - HIGH complexity passwords must contain at least 15 characters such that:
The password must contain at least one uppercase alphabetic character.
The password must contain at least one lowercase alphabetic character.
The password must contain at least one numeric character.
The password must contain at least one special character.
The password must not contain more than three consecutive repeating characters.
Note: If the current password does not meet the high complexity password requirements, when this option is selected the panel will prompt you to change the current password to one that does meet the high complexity requirements.
Set Password: Select this option to open the Enter Password window (FIG. 101).
DEVICE ADMINISTRATION
The Device Administration options are only available if the panel is in standard security mode. When the Enforce High Security Profile option is selected, Microphone , Bluetooth , Camera and NFC functionality is forced OFF , forced disabled , and the these functions cannot be toggled on until the panel is returned to standard security mode.
Enable Microphone If this switch is on, then the internal microphone is enabled. If the switch is off, then the internal microphone is disabled. If the panel is in Standard Security mode, the Enable Microphone option can be enabled/disabled.
In High Security mode, the microphone is automatically disabled.
Enable Bluetooth
Enable Camera
Enable NFC
USB Security
If this switch is on, then the Bluetooth subsystem is enabled. If the switch is off, the Bluetooth subsystem is disabled: this switch mimics the Bluetooth switch under Connections in the Settings menu. If the panel is in
Standard Security mode, the Enable Bluetooth option can be enabled/disabled. In High Security mode,
Bluetooth functionality is automatically disabled.
If this switch is on, the internal camera is enabled. If the switch is off, the internal camera is disabled.
If the panel is in Standard Security mode, the Enable Camera option can be enabled/disabled. In High
Security mode, the camera is automatically disabled.
Note: Some applications may or may not function correctly if the application accesses the camera when the camera is disabled.
If this switch is on, the NFC subsystem is enabled. If the switch is off, the NFC subsystem is disabled: this switch mimics the Enable/Disable switch on the CONNECTIONS - NFC
page (see page 53). If the panel is in
Standard Security mode, the Enable NFC option can be enabled/disabled. In High Security mode, NFC functionality is automatically disabled.
This field displays the current level of USB security applied to this panel (default = Enable All ). Press to change this setting via the USB Security Options
window. See Changing USB Security Settings on page 64.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 61
Settings Menu
Security page options (Cont.)
SYSTEM SERVICES
The System Services options are only available if the panel is in standard security mode. When the Enforce High Security Profile option is selected, VNC , SIP , Content Sharing and Update Manager Web Services functionality is forced OFF , forced disabled , and the these functions cannot be toggled on until the panel is returned to standard security mode.
Note: SSH is unchanged in High Security Mode. It is the only system service that can remain enabled in High Security Mode.
VNC Server
SIP Connections
If this switch is on, the VNC Server is enabled. If the switch is off, the VNC Server is disabled: this switch mimics the Enable/Disable
switch on the DEVICE - VNC page (see page 37). If the panel is in Standard
Security mode, the VNC Server option can be enabled/disabled. In High Security mode, VNC functionality is automatically disabled.
If this switch is on, the SIP client subsystem is enabled. If the switch is off, the SIP client subsystem is disabled: this switch mimics the Enable/Disable
switch on the DEVICE - SIP page (see page 41). If the panel
is in Standard Security mode, the SIP Connections option can be enabled/disabled. In High Security mode,
SIP functionality is automatically disabled.
SSH Connections If this switch is on, the SSH Server is enabled. If the switch is off, the SSH Server is disabled: this switch mimics the SSH
switch on the SYSTEM - Diagnostics page (see page 77). The
SSH Connections option can be enabled/disabled in both Standard and High Security modes (not automatically disabled when the panel is placed in High Security mode)
Content Sharing Sender If this switch is on, the Content Sharing Sender subsystem is enabled. If the switch is off, the Content
Sharing Sender is disabled: this switch mimics the Enable switch on the DEVICE - Content Sharing page (see
page 38). If the panel is in Standard Security mode, the
Content Sharing Sender option can be enabled/ disabled. In High Security mode, Content Sharing is automatically disabled.
Update Manager Web
Services
If this switch is on, the Update Manager will attempt to connect to the Update Manager Server (hosted on amx.com). If the switch is off, then the Update Manager will not attempt to connect to the Update Manager
Server: this switch mimics the Web Services
switch on the Reset and Update page (see page 66).
If the panel is in Standard Security mode, the Update Manager Web Services option can be enabled/disabled.
In High Security mode, Update Manager Web Services functionality is automatically disabled.
Audit Logging
APPLICATIONS
If this switch is on, audit logging to the NetLinx Master syslog client is performed over ICSP (default = OFF).
Allow only SECURE applications to be installed
If the panel is in Standard Security mode, select this option to allow only "secure" applications to be installed on this panel. In High Security mode, this option is automatically selected.
Note: Applications are considered to be non-secure if they permit access to the web or to a file system.
When this option is selected (or when the panel is High Security mode), non-secure applications will automatically be disabled and/or uninstalled:
• All non-secure user installed applications are uninstalled
• All non-secure pre-installed applications are disabled
CREDENTIAL STORAGE
Trusted Credentials
Install from storage
Press to display a listing of the trusted certificates currently saved on this panel (see page 65).
Press to install certificates from an attached USB drive (see page 65).
Clear credentials
Press to remove all certificates that have been installed on th is panel (see page 66).
DEFAULT SECURITY SYSTEMS
Restore Default System
Security Settings
This option restores the default system security settings:
When this option is selected, all Security settings are returned to the default (Standard) security values and the password is changed to the default " 1988 ".
Placing the Panel in High Security Mode
G5 Panels support two security profiles: Standard and High Security :
Standard Security mode is the default mode - it requires a password to access the Settings pages, except Device Info and
Maintenance . The default password is " 1988 ".
High Security mode is enabled via the Enforce High Security Mode option at the top of the Security Settings page - it also requires a password to access the Settings pages. However, there are specific complexity requirements that must be met for the password.
To place the panel in High Security Mode:
1.
On the SYSTEM > Security Settings page, toggle the Enforce High Security Profile option to ON
FIG. 95 SECURITY PROFILE - Enforce High Security Profile option
2.
The panel will alert you to the fact that enabling the High Security profile will disable several system services, and that the password may need to be changed. Press Yes
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 62
Settings Menu
FIG. 96 Enable High Security Profile dialog
NOTE: In High Security mode, all System Services except SSH are automatically disabled, and cannot be enabled unless the security
mode is changed back to Standard. Refer to the Storage page options section on page 26
(SYSTEM SERVICES section) for details.
3.
The panel will prompt you to create a new password that meets the minimum complexity requirements for High Security mode
FIG. 97 Update Password dialog
4.
Press OK to invoke the Enter Password
FIG. 98 Enter Password window
5.
Press the Enter Password field to invoke the on-screen keyboard, and enter a new password that meets the minimum complexity requirements for High Security mode:
The password must contain at least one uppercase alphabetic character.
The password must contain at least one lowercase alphabetic character.
The password must contain at least one numeric character.
The password must contain at least one special character.
The password must not contain more than three consecutive repeating characters.
6.
Press the Enter Password Again field to invoke the on-screen keyboard, and re-enter the new password. Press OK to save the new password and close this window.
At this point, the panel has been put into High Security Mode. Note that the DEVICE ADMINISTRATION and SYSTEM SERVICES options (expect for SSH Connections ) are disabled. These options are only available in Standard Security Mode.
Switching From High Security Mode to Standard Security Mode
To return a panel that is in High Security Mode to Standard Security mode:
1.
Press the Enforce High Security Mode option to toggle it from ON to OFF
FIG. 99 SECURITY PROFILE setting
2.
The panel will alert you to the fact that disabling the High Security profile will reset several system services to their default values, and that the password will not be changed. Press Yes
FIG. 100 Disable High Security Profile dialog
The panel is now in Standard Security Mode.
NOTE: Switching from High Security mode to Standard Security mode does not automatically change the Password Complexity setting, or reset the current password. Therefore, when the panel is switched from High to Standard Security, the High Complexity password is still required, until a new password is set. To set a new password with Standard complexity, select STANDARD in the
Password Complexity field. Then, you can use the Set Password option to set a new password without complex password requirements.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 63
Changing the Password
1.
In the Security page, select Set Password . This opens the Enter Password window (FIG. 101).
Settings Menu
FIG. 101 Enter Password window
2.
Enter the new alphanumeric password.
3.
Press OK when complete.
Note that the Password Complexity setting determines the requirements for the new password:
If set to STANDARD, there are no particular requirements for the new password.
If set to High, the complexity requirements for the new password are:
The password must contain at least one uppercase alphabetic character.
The password must contain at least one lowercase alphabetic character.
The password must contain at least one numeric character.
The password must contain at least one special character.
The password must not contain more than three consecutive repeating characters.
Changing USB Security Settings
By default, the panel has all USB security options enabled (as indicated by the Enable All
entry in the Security page (FIG. 102):
FIG. 102 Security Page - USB Security setting indicating Enable All (the default setting)
1.
To disable USB security options on this panel, press USB Security to access the USB Security Options
FIG. 103 USB Security Options window
2.
Select the desired security feature to enable ( Enable All , Disable Storage , Enable Smart Card , or Disable All ).
3.
This selection automatically closes the USB Security Options window and applies the selected option.
NOTE: Click Cancel to close this dialog without making a selection.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 64
Displaying Trusted Credential Certificates
1.
In the Security page, press the Trusted Credentials option.
2.
The credentials detected on this panel are listed, organized by Certificate Type (FIG. 104):
Settings Menu
FIG. 104 Security page - Example Trusted Credentials list
3.
Supported Certificate Types include Trusted CA and 802.x1. Note that each list has two tabs: System and User . To select which type of certificate to display, select either Trusted CA or 802.x1
from the Certificate Type
FIG. 105 Security page - Certificate Type menu
NOTE: The default setting is Trusted CA .
4.
Press the return button to return to the main Security page.
Installing Credential From Storage
1.
In the Security page, press the Install From Storage option.
2.
Select the type of certificate that will be installed: Trusted CA or 802.x1
FIG. 106 Select a Certificate Type window
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 65
Settings Menu
3.
In the Certificate File Browser
window, select the certificate file on the attached USB drive that will be installed (FIG. 107):
FIG. 107 Select a Certificate Type window (indicating no certificate files found)
4.
The selected certificate is installed on the panel.
Clearing Credentials
1.
In the Security page, press the Clear Credentials option. This options clears all credentials installed on this panel.
2.
In the confirmation window, press OK
FIG. 108 Confirm - Remove all the credentials
Restoring the Default System Security Settings
1.
In the Security page, press the Restore Default System Security Settings option.
2.
In the confirmation window, press Yes
FIG. 109 Confirm - Restoring the Default Security Settings
3.
All Security settings are returned to the default (Standard) security values and the password is changed to the default " 1988 ".
SYSTEM - Reset and Update
The Reset and Update
firmware from an external drive.
Scroll down to see all menu items
FIG. 110 Reset and Update page
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 66
Settings Menu
Reset and Update page options
DEVICE RESET
Factory Data Reset
Reset Settings
Load Settings
Store Settings
UPDATE MANAGER
Web Services
Erases all data on the panel and resets the panel back to it’s factory default settings. See
Factory Data Reset on page 67 for details.
Select to revert the panel back to its default settings, but does not erase all data from the panel.
Select to load a saved settings configuration file (".acfg).
Select to save the current settings configuration file at the root of the connected USB drive.
Firmware Manager
App Manager
Scheduled Updates
Use this switch to toggle Update Manager Web Services on the panel: If this switch is on, the Update Manager will attempt to connect to the Update Manager Server (hosted on amx.com). If the switch is off, then the
Update Manager will not attempt to connect to the Update Manager Server.
Note: If the panel is in Standard Security mode, the Update Manager Web Services option can be enabled/ disabled. In High Security mode, Update Manager Web Services functionality is automatically disabled. See the
SYSTEM - Security section on page 60 for details.
Select to open the Firmware Manager page. Use the options on this page to update the firmware on the panel.
See the Firmware Manager section on page 69 for details.
Note: G5 Firmware can also be updated via the NetLinx Studio software application. See
Upgrading Firmware via NetLinx Studio on page 179 for details.
Select to open the App Manager page. Use the options on this page to update the applications on the panel.
See the App Manager section on page 72 for details.
Select this option to access the Scheduled Update options. These options allow you to control if and when automatic scheduled application updates will be made to the panel. See the
Scheduled Updates section on page 74 for details.
PANEL PAGES
Install Pages From
External Disk
Remove User Pages
Select this to open the TPDesign5 File Browser
Select this to remove all previously loaded user pages from the panel.
Factory Data Reset
To reset the panel to its factory defaults and remove all data stored in the panel (including user pages):
1.
Under DEVICE RESET , press Factory Data Reset to open the Factory Data Reset window (FIG. 111).
FIG. 111 Factory Data Reset window
To return to the Reset and Update page without making any changes, press Reset and Update .
2.
To erase all data from the panel, press Reset Device .
Reset Settings
To reset the Settings values to their default values:
1.
Under DEVICE RESET , press Reset Settings.
2.
The panel will prompt you to verify this action (FIG. 112):.
FIG. 112 Reset Settings prompt window
3.
Press Yes to proceed. To return to the Reset and Update page without saving any changes, press No .
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 67
Settings Menu
Storing and Loading Settings Configuration Files
G5 panels have many settings. - the Store Settings and Load Settings options on the Reset and Update page provide the ability to store and load these settings to and from a Settings Configuration File (*.acfg). Use cases include:
Backing up final system settings
Create settings configuration files ahead of time to help with large deployments of panels.
Storing the Current Settings
1.
In the Reset and Update page, press Store Settings to open the Store Settings
FIG. 113 Store Settings window
2.
Enter a unique file name for this settings configuration file (default = " settings.acfg
").
The UI will check for a valid config filename as it's being entered. Invalid entries will not be saved.
3.
Press OK to save the file at the root of the USB drive.
If the filename exists, the system will prompt you to verify overwriting the file.
Loading Settings
Configurations can be loaded from a file on the file system or from a URL:
1.
In the Reset and Update page, press Load Settings to open the Setting Config File Browser
FIG. 114 Setting Config File Browser window
2.
This window lists all settings configuration (*.acfg) files present on the USB Storage media.
3.
Select the desired settings configuration file.
4.
The panel will prompt you to verify this action (FIG. 115):
FIG. 115 Open File window
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 68
Settings Menu
Firmware Manager
Select Firmware Manager under UPDATE MANAGER in the Reset and Update
page to access the Firmware Manager page (FIG. 116):
FIG. 116 Firmware Manager window
Reverting to Previous Firmware
To reset the panel to its previously installed firmware:
1.
From the Firmware Manager
Revert to Previous Firmware . If no previous version is available, this field is disabled
2.
A System Message window is displayed that indicates the previous firmware version that will be installed, and prompting you
to verify this action (FIG. 117):
FIG. 117 System Prompt - Revert To Previous Firmware?
3.
Select OK to install the previous firmware version and Cancel to return to the Firmware Manager .
4.
If you choose OK , the panel will reboot and restart with the previously installed firmware.
Reverting to Factory-Installed Firmware
In certain circumstances, it may be necessary to uninstall the current firmware on a panel and return it to the original factory default firmware. To reset the panel to its original factory firmware:
1.
From the Firmware Manager
window (FIG. 116 on page 69), select
Revert to Factory Firmware .
2.
A System Message window is displayed that indicates the factory firmware version that will be installed, and prompting you to
verify this action (FIG. 118):
FIG. 118 System Prompt - Revert To Factory Firmware?
3.
Select OK to install the previous firmware version and Cancel to return to the Firmware Manager .
4.
If you choose OK , the panel will reboot and restart with the factory installed firmware.
NOTE: Resetting the panel to its original factory firmware will remove all updates made to the Settings menu since that version.
Installing New Firmware From An External USB Stick
To install new firmware to the panel from a USB stick:
NOTE:
Studio on page 179 for details.
1.
Download the latest G5 panel firmware from www.amx.com
and save it to a USB stick or other external drive with USB capability.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 69
Settings Menu
NOTE: The firmware can be saved at the root directory, or be saved in a folder in the USB stick directory.The folder name is not case sensitive.
2.
Insert the USB stick into an available USB port. This may require disassembling wall-mounted panels to access the USB ports if a USB extension was not already installed.
3.
From the Firmware Manager
window (FIG. 116 on page 69), select
Install Firmware from USB to open the KIT File Browser
FIG. 119 KIT File Browser window
4.
Select the KIT file to be installed.
5.
The panel will upload the new firmware (FIG. 120) and then reboot.
FIG. 120 Update Progress display
Install Firmware From Web
If any firmware updates are available for the panel, the Install Firmware From Web option is presented on the Firmware Manager
SYSTEM - Security section on page 60 for details on security modes.
To install new firmware to the panel from the web:
1.
From the Firmware Manager
window (FIG. 116 on page 69), select
Install Firmware from Web.
2.
FIG. 121 AMX Web Update - Checking for updates
3.
The web update utility will display the available update versions (FIG. 122):
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 70
Settings Menu
FIG. 122 AMX Web Update - Available updates
Press View Readme to review the firmware update Readme file prior to installation.
Press Cancel to close this window without updating the panel firmware.
4.
Select the firmware version that will be used to update the panel and press Install Update to initiate the firmware update. The panel will prompt you to verify this action - Press OK
to proceed with the update (FIG. 123):
FIG. 123 System Prompt - Install Firmware From Web
5.
The progress of the download is indicated on the Firmware Manager
FIG. 124 Firmware Manager page - Install Firmware Fro m Web (in progress)
6.
The firmware update will begin the install process (FIG. 125):
FIG. 125 Firmware Update - Preparing Firmware
7.
After copying the firmware package to the staging location, the panel will reboot and complete the firmware installation
FIG. 126 Firmware Update - reboot and complete firmware update
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 71
Settings Menu
App Manager
Select App Manager under UPDATE MANAGER in the Reset and Update page to access the App Manager page. Note that this page has two tabs: AVAILABLE (initial view) and INSTALLED.
App Manager Page - AVAILABLE tab
The options in the AVAILABLE
tab (FIG. 127) are described below:
FIG. 127 App Manager window (AVAILABLE tab)
App Manager page - AVAILABLE tab options
Update All button
UPDATES
NATIVE
DOWNLOADS
Install Apps from USB
Press to install all application updates listed in the UPDATES section. See
Installing All Available Updates
(below) for details.
This section lists any updates found for applications that are currently installed on the panel. See the
Updating Individual Applications section on page 72 (below) for details.
This section lists any native applications (pre-installed/system applications) that are currently disabled . See the
Enabling Native (Disabled) Applications section on page 72 for details.
This section lists any new applications that can be installed on the panel.
From an External USB Drive section on page 73 for details.
Installing All Available Updates
Press UPDATE ALL
(at the top of the UPDATES section) to update all installed applications (FIG. 128):
FIG. 128 App Manager window (AVAILABLE tab) - UPDATES options
Updating Individual Applications
Press UPDATE (in the UPDATES section) to update individual applications. Press README to view any release notes that are
available for the update (FIG. 128).
Enabling Native (Disabled) Applications
Press ENABLE (in the NATIVE section) to enable any native applications (pre-installed/system applications) that are currently disabled
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 72
Settings Menu
FIG. 129 App Manager window (AVAILABLE tab) - UPDATES options
Installing Downloaded Applications
Press INSTALL (in the DOWNLOADS section) to install downloaded applications. Press README to view any release notes that are
available for the application (FIG. 130):
FIG. 130 App Manager window (AVAILABLE tab) - DOWNLOADS options
Installing Applications From an External USB Drive
This feature provides a method of applying application updates distributed by AMX at sites that cannot access the Internet, or that have Update Manager web services disabled. To use this feature, load the application (APX files) on an external USB drive and plug the USB drive into the G5 panel.
1.
Press OPEN in the Install Apps from USB section
of the App Manager page (FIG. 131) to open the
APX Install
FIG. 131 App Manager window (AVAILABLE tab) - Install Apps from USB (OPEN) option
The options on the APX Install
page allow you to install applications from an external USB Drive (FIG. 132):
FIG. 132 App Manager window (AVAILABLE tab) - Install Apps from USB (OPEN) option
When the APX Install page opens, the root directory of the connected USB drive will be scanned for APX files. Once the scan is complete, the UI will be populated with APX files that are valid for the device.
This page is divided into two sections: UPDATES and INSTALLS
UPDATES Shows any valid APX files for this device that are updates to currently installed applications.
INSTALLS Shows any valid APX files for this device that are new installs.
2.
Press the box on the left hand side to select the apps to install.
3.
Once all apps have been selected for installation/update, press Install .
Once the Install button is pressed, only the selected items will be visible in the APX Install page. The right hand side of each line
item will show the progress of the install (FIG. 133):
FIG. 133 APX Install Page - indicating one app installed and one installation in process
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 73
App Manager Page - INSTALLED tab
The options in the INSTALLED tab of the App Manager page (FIG. 134) are described below:
Settings Menu
FIG. 134 App Manager window (INSTALLED tab)
App Manager page - INSTALLED tab options
NATIVE
DOWNLOADS
This section lists any native applications (pre-installed/system applications) that are currently enabled .
This section lists any applications that were downloaded and installed to the panel.
Press Uninstall
to remove these applications from the panel. See Uninstalling Downloaded
Applications section on page 74 for details.
Disabling Native Applications
Press Disable to disable any of these applications.
Note that once a native application has been disabled, it is moved to the AVAILABLE tab - NATIVE section.
Uninstalling Downloaded Applications
Press UNINSTALL next to any application listed in the DOWNLOADS section of the App Manager page (INSTALLED) tab to uninstall downloaded applications.
Scheduled Updates
Select Scheduled Updates under UPDATE MANAGER in the Reset and Update page to access the Scheduled Updates options shown
FIG. 135 Reset and Update page - Scheduled Updates options
Scheduled Application Updates
When this option is selected, the Update Manager will only check for application updates when an Scheduled Update is performed.
By default, this option is disabled.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 74
Settings Menu
Scheduled Update Days
Press this option to select the day(s) on which the Update Manager will check for Scheduled Updates, via the Scheduled Update
Days
FIG. 136 Scheduled Update Days window
The Update Manager will perform a Scheduled Update at the time set by the Scheduled Update Time setting (see below).
Touch outside the dialog to cancel the dialog and revert to the previous values.
Scheduled Update Time
Press this option to select the time (hour and minute) on which the Update Manager will check for Scheduled Updates, via the
Scheduled Update Days
FIG. 137 Scheduled Update Time window (Standard and 24-Hour Time formats)
The Time format displayed on the panel is set via the Use 24-Hour Format option on the Date & Time page (see page 49).
Update Applications on Startup
When this option is selected, the Update Manager will check for updates when the panel starts. By default, this option is disabled.
Installing Panel Pages From an External Disk
TPDesign5 page files (*.tp5) may be loaded onto a panel, both via TPDesign5 and through files saved to a USB-enabled external drive. To load TPD5 pages via USB:
1.
Download the panel pages and save them to a USB stick or other external drive with USB capability.
2.
Insert the USB stick into an available USB port on the panel.
3.
In the Reset & Update window, press Install Pages from External Disk (under PANEL PAGES) to open the TP5 File Browser
window. All TP5 files found on the USB drive are listed (FIG. 138):.
FIG. 138 TPDesign5 File Browser window
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 75
4.
Press the TP5 file to load on the panel.
5.
The panel will prompt you to verify this action (FIG. 139):
FIG. 139 TP5 Update prompt
6.
Press Yes to load the selected TP5 project on the panel.
Removing User Pages From the Panel
To remove user pages from the panel:
1.
In the Reset and Update page, press Remove User Pages to open the Remove User Pages
Settings Menu
FIG. 140 Remove User Pages prompt
2.
Press Yes to remove the user pages from the panel.
At this point, the panel will indicate that there are no device pages installed (FIG. 141):
FIG. 141 No Device Pages Installed window
Press one of the options presented on this page to proceed:
Launch Settings : Press to invoke the Setting menu. Use this option to navigate to the SYSTEM > Reset & Update window to use the Install Pages from External Disk option to load pages via a TP5 file (see
Installing Panel Pages From an External
Launch Default Profile : Press to launch the default panel profile.
Launch Applications : Press to invoke the Available Apps window, which provides shortcuts to all Apps loaded on the panel
FIG. 142 Available Apps window,
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 76
Settings Menu
SYSTEM - Diagnostics
The Diagnostics
functionality.
FIG. 143 Diagnostics page
Diagnostics page options
Temperature Displays the current temperature of the panel in Celsius.
Logs Select this option to display the panel logs.
SSH Select this option to enable or disable the SSH server on this panel.
Refer to the
SSH Commands section on page 170 for a listing of supported SSH commands.
The Logs window chronicles all previous connections between the panel and the network. To access the Logs window, select Logs in the Diagnostics page.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 77
Using Content Sharing
Using Content Sharing
Overview
This section describes using the Content Sharing application on a G5 panel to initiate content sharing to an Enzo.
These instructions assume that the G5 panel and the Enzo unit(s) in the system have already been configured to use Content
Sharing. Refer to the
and configuring one or more Enzo units as receivers for shared content.
Content Sharing Icon
Look for the Content Sharing icon in the G5 Menu Bar at the bottom of application windows. Anytime you see the Content Sharing
FIG. 144 Content Sharing icon (Gallery application with image file selected)
Notes on Content Sharing
To share content, an individual file (as opposed to a directory) must be selected for sharing. Although the Content Sharing icon is displayed in some cases when a file is not selected, the Content Sharing feature only applies to selected files.
Content Sharing is supported for the following applications:
PDF Viewer
Browser
File Browser
Gallery
PlanMaker Mobile
Presentations Mobile
TextMaker Mobile
Content Sharing is supported for the following file types:
Content Sharing - Supported File Types: ".doc", ".docx", ".docm", ".dotm", ".dot",
".xlt", ".xls", ".xlsx",
".ppt", ".pptx", ".pps",
".pdf", ".txt", ".rtf", ".sxw", ".tmd", ".odt",
".mp3", ".mp4", ".mov", ".avi", ".3gp", ".flac",
".ogg", ".wav", ".jpg", ".gif", ".png", ".bmp", ".webp",
".ts", ".mkv", ".webm"
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 78
Using Content Sharing
Some application provide their own "sharing" functions, which are not necessarily the same as the Content Sharing feature used to share with Enzo units. For example, at the top of the Image View page, there is an application-specific "Share" icon.
Content Sharing is not available via this menu.
FIG. 145 Application "Share" icon, and Content Sharing icon (as displayed in an Image View page)
Some applications may also present the Content Sharing icon in multiple places. Anywhere that the Content Sharing icon is
Sharing icon is displayed at the top of the window next to the application’s "Share" icon. Content Sharing can be invoked either via this icon or the Content Sharing icon presented in the G5 Menu Bar at the bottom of the window.
In cases where the application presents a "Share" function as an application-specific feature, "Content Sharing" is often
included as an option (FIG. 146). In this case, select
Content Sharing to share with Enzo.
FIG. 146 Application "Share" icon, and Content Sharing icon (as displayed in an Image View page)
Sharing Content From a Modero X G5 Touch Panel
The following instructions outline the basic workflow of sharing content from the G5 panel to the Enzo. To follow these instructions, you’ll need a USB drive with at least one file saved on it.
In this example, we will select a file to share in the File Browser application on a G5 panel:
1) Select a File and press the Content Sharing Icon
1.
Plug a USB stick loaded with the file(s) that will be shared into an available USB port on the G5 panel.
2.
On the G5 panel, open the File Browser application to view the files that are the USB stick.
Note that in the File Browser application, Content Sharing icons are presented for each file. An example view of the File
Browser application is shown in FIG. 147:
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 79
Using Content Sharing
FIG. 147 File Browser - Content Sharing Icons
FIG. 148 Presentation Application - Content Sharing icon
3.
Press the Content Sharing icon to share the file.
2) Select the Enzo To Send Shared Content To (if prompted)
If more than one Enzo exists in the panel’s Receivers list, the panel will prompt you to specify which of the Enzo units in the system to send the shared content to when the Content Sharing icon is pressed.
If there is only one Enzo present in the panel’s Receiver List, then this prompt is not displayed.
Refer to the
1.
If there are multiple Enzo units configured to use Content Sharing with the G5 panel, then a list of Enzo units is displayed to select from, in the Receiver Selection window (FIG. 149).
FIG. 149 G5 panel - Receiver Selection
2.
Select the Enzo to send the shared content to. In this case, once an Enzo (Receiver) is selected, communication is established between the G5 panel and the selected Enzo unit, and the file is transferred to the Enzo.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 80
Using Content Sharing
3) On the Enzo, Confirm the Share Request (if prompted)
Depending on how the Enzo unit has been configured, the Share Request confirmation dialog may be presented (FIG. 150). If this dialog is displayed, press OK to allow the share request:
FIG. 150 Enzo - Share Request confirmation dialog
Note that the device name (“ Device 3001 ” in FIG. 150) will be replaced with the device name assigned to the G5 panel that is sending the shared file.
When the user presses OK , the shared content is displayed.
If the Enzo is not configured to display this dialog, then the content is shared immediately.
Error Messages
For the most part AMX Share operates silently in the background. However, there are some scenarios where error conditions are reported back to the user.
If the G5 panel is unable to communicate with an Enzo for some reason (wrong credentials, wrong port number, wrong hostname/ ip, Receiver is disabled, etc), the following error will be presented (FIG. 151):
FIG. 151 Error - Receiver unavailable
FIG. 152 Error - No Receiver Error
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 81
Gestures
Gestures
Overview
You can program Modero X Series touch panels, using the commands in this section, to perform a wide variety of operations using
Send Commands and variable text commands.
A device must first be defined in the NetLinx programming language with values for the Device: Port: System (in all programming examples - Panel is used in place of these values and represents all Modero panels).
NOTE: Verify you are using the latest NetLinx Master and Modero firmware, as well as the latest version of NetLinx Studio and TPD5.
NOTE: For more information on gestures and on designing touch panel pages, please refer to the TPDesign 5 online help, available at www.amx.com.
Touch Gesture Recognition
Gesturing refers to the act of moving a finger or stylus across the overlay and having the panel recognize and process this motion as a gesture. In G5, gesture events are assigned as individual buttons or pages. In addition, a gesture velocity is calculated and transmitted to the master along with the gesture type itself in a custom event message.
NOTE: Nothing will be processed if the button associated with this gesture has no gesture event operations programmed, is disabled, or has no values programmed for address, channel, level, string output or command output. The custom event, however, is always transmitted.
The following gesture types are supported:
1.
Swipe up
2.
Swipe down
3.
Swipe right
4.
Swipe left
5.
Double-tap
6.
2 Finger Swipe Up
7.
2 Finger Swipe Down
8.
2 Finger Swipe Right
9.
2 Finger Swipe Left
Gesture Velocity
A gesture “velocity” is calculated to represent the speed of the gesture. This is done by measuring the time from when the user first presses the screen until the user releases. The following simplified velocities are supported and transferred to the master in the custom event message:
1.
Fast
2.
Normal
3.
Slow
A precise velocity is sent in the custom event message which represents the velocity in terms of pixels per second for slides and circles. For a double tap, this value is the total time in milliseconds from the first press to the second release.
Gesture Prioritization
The following table describes the process used to determine what the user meant whenever a gesture operation is defined globally versus for the current page.
Gesture Prioritization
The user presses outside of a button or slider and moves before releasing.
The user presses inside of a slider and moves before releasing.
The user moves a movable popup page.
The user presses on a button and then moves.
The firmware will always try to recognize a gesture as long as the user moves at least 20 pixels before the release occurs.
This will always be processed as a slider operation and no attempt will be made to recognize a gesture.
This will always be processed as a popup page move and not a gesture.
The user double taps on a button or slider.
The user double taps outside of a button or slider.
In this case, the press will not be sent for the first 0.15 second. If the user has moved at least 60 pixels by this time, then a button press/release will not be processed, but this will be processed as a gesture.
At 0.15 second, the button press is processed and once the user releases, the release is processed and no gesture recognition is attempted. To be clear, it is not necessary for the user to move off of a button to be considered a gesture, but to move at least 60 pixels in that first 0.15 of a second.
This will not be recognized as a gesture. This would be considered two quick press/release operations on the button or slider.
This will be registered as a gesture.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 82
Gestures
Gesture VNC/Mouse Support
Gestures are recognized when the user is using a finger or stylus on the panel's screen overlay, a mouse on a VNC connection, or a mouse connected to the local USB port on the panel.
Gesture Custom Event
Whenever a gesture is recognized and processed a custom event is also sent to the master. The following values describe this event:
CUSTOM_EVENT ADDRESS is 1
CUSTOM_EVENT EVENTID is 600
Custom.Value1 is the gesture number
Custom.Value2 is the simplified gesture velocity
Custom.Value3 is the precise gesture velocity
Gesture numbers and velocity values
Gesture Numbers and Velocity Values
Gesture numbers
1 - Swipe up
2 - Swipe down
3 - Swipe right
4 - Swipe left
5 - Circle (not implemented)
6 - CCW Circle (not implemented)
7 - Double-Tap
8 - Two-Finger Swipe up
9 - Two-Finger Swipe down
10 - Two-Finger Swipe right
11 - Two-Finger Swipe left
Simplified gesture velocity values
1 - Fast
2 - Normal
3 - Slow
Precise gesture velocity
For double taps, this is the time in milliseconds from the first press to the second release.
Enabling or Disabling the Gesture Custom Event
The ^GCE Send Command sets whether or not the panel sends a custom event to the master whenever a gesture is detected (see
The value sent is not retained - gesture custom events will be enabled each time the panel restarts.
The default is to always NOT send the events.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 83
MXA-MP and MXA-MPL Programming
MXA-MP and MXA-MPL Programming
Overview
The MXA-MP Modero X Series Multi Preview and MXA-MPL Multi Preview Live are touch panel accessories that display still images or an HD digital video stream on Modero X Series touch panels. The MXA-MP accepts analog or digital video inputs and converts them into up to 10 regularly refreshed JPEG preview images. The MXA-MPL accepts analog or digital video inputs over HDMI and converts them to a video stream. Both devices make it easy for users to identify quickly what is currently being displayed by up to 10 source devices.
NOTE: Verify you are using the latest NetLinx Master and Modero firmware, as well as the latest version of NetLinx Studio and TPD5.
NOTE: For more information on the MXA-MP and MXA-MPL, such as firmware upgrades, please refer to the MXA-MP/MPL Instruction
Manual , available at www.amx.com.
Configuring the Touch Panel
After physically connecting the device to the local network, and connecting the Modero X Series touch panel to the device, enable the device through the touch panel’s Multi Preview
page (FIG. 153). For more information on the
Multi Preview menu, please refer to the
CONNECTIONS - Multi Preview section on page 51.
FIG. 153 Multi Preview menu
Stand-Alone Images and Video Feeds
Adding a Preview Image to a Touch Panel Page
As an example of how to add a simple JPEG preview image to a touch panel page in TPDesign 5:
1.
From the main TPDesign 5 menu, select Panel / Resource Manager and select the Dynamic Images tab.
2.
Select a JPEG image in the project. In this example, call it MXA_MP .
3.
In the Select Resource
window (FIG. 154), add a new resource. In the example.
Protocol: HTTP
Host: mxamp
Path: snapit
File: slot1.jpg
In this example, make sure to use at least a 2-second Refresh Rate.
4.
When finished, click OK t o close the Select Resource window.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 84
MXA-MP and MXA-MPL Programming
FIG. 154 Edit Dynamic Image window
5.
After adding the Dynamic Image, assign the image as a Bitmap to a button on a touch panel page.
Adding a Live Motion Stream To A Touch Panel Page via an MXA-MPL
To add a live motion stream to a touch panel page via an MXA-MPL:
1.
In the touch panel page, draw a button to be the video window.
2.
In Button States , select MXA-MPL
FIG. 155 Button Properties
Supported Resolution/Signal Type Commands
When using the MXA-MPL for displaying live motion streams, make sure to use the supported resolutions with the video input type:
Supported Resolution/Signal Type Commands
HDMI:
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=hdmi,640x480p@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=hdmi,800x600p@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=hdmi,1024x768p@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=hdmi,1280x720p@30'"
DVI: SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=dvi,640x480p@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=dvi,800x600p@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=dvi,1024x768p@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=dvi,1280x720p@30'"
RGB/Graphics:
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=vga,640x480p@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=svga,800x600p@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=xga,1024x768p@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=wxga,1280x768p@30'"
Component:
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=component,720x480i@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=component,720x480p@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=component,720x576i@30'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=component,720x576p@25'"
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 85
MXA-MP and MXA-MPL Programming
Supported Resolution/Signal Type Commands
SVIDEO: SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=svideo,ntsc'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=svideo,pal-bghid'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=svideo,pal-m'"
Composite:
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=composite,ntsc'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=composite,pal-bghid'"
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=composite,pal-m'"
NOTE: When using the MXA-MPL for displaying live motion streams, make sure to use the supported resolutions with the video input type. While the MXA-MPL is capable of supporting up to 60 Hz, the Modero X G5 panels that use MXA-MPL only support 25-30 Hz.
Code-Driven Buttons and Video Feeds
Example code is available from AMX to assist with developing individual solutions for producing dynamic buttons and/or video feeds. From either the MXA-MP or MXA-MPL product pages on www.amx.com
, select the AMX Device Modules link on the right side of the page. This example code is open source and may be modified to function with any source capable of providing the specified resolution and signal type.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 86
Programming - Send Commands
Programming - Send Commands
Overview
You can program Modero X Series G5 touch panels, using the commands in this section, to perform a wide variety of operations using Send Commands and variable text commands.
NOTE:
A device must first be defined in the NetLinx programming language with values for the Device: Port: System (in all programming examples - Panel is used in place of these values and represents all Modero panels).
Verify you are using the latest NetLinx Master and Modero X Series G5 firmware, as well as the latest version of NetLinx
Studio and TPDesign5.
The Send Commands described in this document are case -insensitive .
Using the "Pipe" ( | ) Character
Previously, in G4, the pipe character ( |) was used to create a new line.
G5 uses carriage return / line feed ($0d,$0a) instead.
The examples below illustrate indicating a new line (between the words "Hello" and "World") in G4 and in G5 programming:
G4 : "'^TXT-200,0,Hello | World'"
G5: "'^TXT-200,0,Hello', $0d,$0a ,'World'"
Panel Commands
Panel Commands
^ABP
ABEEP
^ADB
ADBEEP
^AKB
@AKB
AKEYB
Single Beep Command - Output a single beep. The 'ABEEP' command is implemented for G4 compatibility.
• Syntax :
"'^ABP'" or
"'ABEEP'"
• Variables : None
• Example :
SEND COMMAND Panel,"'^ABP'"
Double Beep Command - Output a double beep. The 'ADBEEP' command is implemented for G4 compatibility.
• Syntax :
"'^ADB'" or
"'ADBEEP'"
• Variables : None
• Example :
SEND COMMAND Panel,"'^ADB'"
Show System Keyboard Command - Brings up system keyboard. When user presses the "Done" button, a string is returned to the master with the user-entered value. The keyboard can be removed either by the Back button or the
"^AKR" command. The '@AKB' and 'AKEYB' commands are implemented for G4 compatibility.
• Syntax :
"'^AKB-[optional initial text];[optional prompt text];[optional hint text];
[optional return prefix];[optional return port]'" or
"'@AKB-[optional initial text];[optional prompt text];[optional hint text];
[optional return prefix];[optional return port]'" or
"'AKEYB-[optional initial text];[optional prompt text];[optional hint text];
[optional return prefix];[optional return port]'"
• Variables :
Initial text : Pre-populated text to appear on keyboard (i.e. default)
Prompt text : Descriptive header to appear above keyboard text entry box
Hint Text : Hint text to appear behind the keyboard text entry box
Return prefix : Prefix to the send string returned to the master. If not specified, the entered text will be preceded by
"AKB-".
Return port : The port number to return the response on if different than the port to which the command is sent.
• Example :
SEND_COMMAND Panel,"'^AKB-username;Enter user name;Enter the name of the user for this panel'"
Present a keyboard with a prompt of 'Enter user name', the initial text of ' username ', and hint text of ' Enter the name of the user for this panel '.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 87
Programming - Send Commands
Panel Commands (Cont.)
^AKP
@AKP
AKEYP
^AKR
@AKR
AKEYR
^APC
?APC
Show System Keypad Command - Brings up system keypad. When user presses the "Done" button, a string is returned to the master with the user-entered value. The keypad can be removed either by the Back button or the "^AKR" command.
The '@AKP' and 'AKEYP' commands are implemented for G4 compatibility.
• Syntax :
"'^AKP-[optional initial text];[optional prompt text];[optional hint text];
[optional return prefix];[optional return port]'" or
"'@AKP-[optional initial text];[optional prompt text];[optional hint text];
[optional return prefix];[optional return port]'" or
"'AKEYP-[optional initial text];[optional prompt text];[optional hint text];
[optional return prefix];[optional return port]'"
• Variables :
Initial text : Pre-populated text to appear on keypad (i.e. default)
Prompt text : Descriptive header to appear above keypad text entry box
Hint Text : Hint text to appear behind the keypad text entry box
Return prefix : Prefix to the send string returned to the master. If not specified, the entered text will be preceded by
"AKP-".
Return port : The port number to return the response on if different than the port to which the command is sent.
• Example :
SEND_COMMAND Panel,"'^APK-John Doe;Enter Username:;Enter the name for the user;
AKP-username-;1'"
Opens a keyboard with the initial text as John Doe , the keyboard prompt as Enter Username: , the Hint text as Enter the name for the user , the return prefix as AKP-username, and the return port as port 1 .
Remove Keyboard/Keypad Command - This command removes any keyboard or keypad that is currently displayed. If it is a non-virtual keyboard or keypad, it is essentially an Abort, because any user-entered text is lost. The '@AKR' and 'AKEYR' commands are implemented for G4 compatibility.
• Syntax :
"'^AKR'" or
"'@AKR'" or
"'AKEYR'"
• Variables : None
• Example :
SEND COMMAND Panel,"'^AKR'"
Remove the displayed keyboard/keypad.
Automatic close application command - Setup alarm times to close all open applications.
• Syntax :
"'^APC-<enable>,[optional alarm time],[optional alarm time]'"
• Variables : enable : 1 to enable alarms, 0 to disable alarms. Default is 1.
Alarm time : Time of day to trigger alarm in HH:mm format. Format is 24 hour values. Up to six alarm times can be set each day. Valid HH formats are 00-23. Valid mm format is 00-59. Invalid formats and parameters will be disregarded.
The default is one time set at 00:00 (midnight).
• Examples :
SEND_COMMAND Panel, "'^APC-1,00:00, 08:00, 18:00'"
Enable the application close alarms at midnight (00:00), 8:00 AM (08:00), and 6:00 PM (18:00).
SEND_COMMAND Panel, "'^APC-0'"
Disable application close alarms.
SEND_COMMAND Panel, "'^APC-1'"
Enable alarms to close applications at previous alarm times.
Query application close alarms - Query the values of the close applications alarms. The response is a NetLinx DATA/
Command event to the master from the port the command was sent to in the format used in the ^APC command.
• Syntax :
"'?APC'"
• Variables : None.
• Example :
SEND_COMMAND Panel, "'?APC'"
Response is a DATA/Command event to master from the port the ?APC command was sent on in the format of:
^APC-<enable>,[optional alarm time],[optional alarm time]
If alarms are enabled and times set to midnight and noon, the response would be:
^APC-1,00:00,12:00
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 88
Programming - Send Commands
Panel Commands (Cont.)
^APP -
Launch application chooser
^APP -
Launch application window
^APP - Close a specific application
Launch application chooser command - Launch a dialog showing all available apps.
• Syntax :
"'^APP'"
• Variables : None
Launch application window command - Launch an application window at the specified location with the specified application
• Syntax :
"'^APP-left,top,<width>,<height>,[optional window type],<AppName>[,<param list>]'"
• Variables : left - The left position of the application window.
top - The top position of the application window.
width - The optional width of the application window. If not specified, the default width of 320 is used.
height - The optional height of the application window. If not specified, the default height of 240 is used.
window type - The optional window type. If not specified, the default window type of floating, resizable, movable is used.
Window type Description
0 Floating, resizable, movable
1 Floating, fixed size, movable
2 Floating, fixed size, non-movable
3 Docked left
4 Docked right
5 Docked top
6 Docked bottom app name The name of the application to launch.
param list The optional comma-separated list of parameter triplets as follows:
<param_1_name>,<param_1_type>,<param_1_value>,...,<param_N_name>,<param_N_type>,<param_N_value> where: name: parameter name (e.g."URI") type: parameter type (e.g. "String") - not case sensitive value: parameter value (e.g. http://www.amx.com)
Note: The name, type and value are separated by a single comma. If there are additional parameters, a single comma should separate the previous parameter's value and the next parameter's name. Since comma is used to delimit the parameter fields, any comma appearing in the value of the element must be escaped with a backslash ('\'). If a backslash itself appears in any element, it too must be escaped with another backslash. To access a file on an attached USB drive, the URI must be: file:///udisk/path_to_file. (Note there are three (3) forward slashes after the file: and you must specify udisk to point to the USB disk.)
• Example :
SEND_COMMAND Panel,"'^APP-0,0,Browser'"
Launch browser in upper left corner
Close a specific application command - Close the application specified.
• Syntax :
"'^APP-<app name>'"
• Variables : app name - The name of the application to close.
• Example :
SEND_COMMAND Panel,"'^APP-Browser'"
Close the browser
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 89
Programming - Send Commands
Panel Commands (Cont.)
^APP -
Application action
?APP
^BRT
@BRT
BRIT
Application action command - Performs a specified action on an application specified by app name .
• Syntax :
"'^APP-<action>,<app name>[,<param list>]'"
• Variables : action : The action to perform on the application. The available actions are: show: show an app, launch if not visible centered on the screen in a floating, moveable, resizable window.
close: close a running app close_all: close all running apps app name : The name of the application to act upon.
param list : The optional comma-separated list of parameter triplets as follows:
<param_1_name>,<param_1_type>,<param_1_value>,...,<param_N_name>,<param_N_type>,<param_N_value> where: name: parameter name (e.g."URI") type: parameter type (e.g. "String") - not case sensitive value: parameter value (e.g. http://www.amx.com)
Note: The name, type and value are separated by a single comma. If there are additional parameters, a single comma should separate the previous parameter's value and the next parameter's name. Since comma is used to delimit the parameter fields, any comma appearing in the value of the element must be escaped with a backslash ('\'). If a backslash itself appears in any element, it too must be escaped with another backslash. To access a file on an attached USB drive, the URI must be: file:///udisk/path_to_file. (Note there are three (3) forward slashes after the file: and you must specify udisk to point to the USB disk.)
• Example :
SEND_COMMAND Panel,"'^APP-show,Browser'"
Show the browser centered on the screen in a floating, movable, resizable window.
SEND_COMMAND Panel,"'^APP-close,Browser'"
Query available application command - Query all the available apps installed.
• Syntax :
"'?APP'"
• Variables : None
App names are sent through a custom event:
Custom Event Property Value
Port port command was received on
ID 1
Type 4170
Flag 0
Value 1 App Number (0 - max number apps in no particular order)
Value 2 Number of available apps
Value 3 n/a
Text App Name (suitable for launching via ^APP,0,0,AppName)
Panel Brightness Command - Set the panel brightness. The '@BRT' and 'BRIT' commands are implemented for G4 compatibility.
• Syntax :
"'^BRT-<brightness level>'" or
"'@BRT-<brightness level>'" or
"'BRIT-<brightness level>'"
• Variable : brightness level = 0 - 100.
• Example :
SEND COMMAND Panel,"'^BRT-70'"
Sets the brightness level to 70
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 90
Programming - Send Commands
Panel Commands (Cont.)
?BRT
^CPR
^DMM
Query Brightness Command - Query panel brightness.
• Syntax :
"'?BRT'"
• Variables : None
• Example :
SEND_COMMAND Panel,"'?BRT'"
Gets the current brightness value.
The response returned is a custom event with the following properties:
Custom Event Property Value
Port port command was received on
ID 0
Type 1303
Flag 0
Value 1 Brightness value 0-100
Value 2 0
Value 3 0
Text String that represents the brightness value
• Example response :
Custom Event Property Value
Port port command was received on
ID 0
Type 1303
Flag 0
Value 1 70
Value 2 0
Value 3 0
Text 70
Cache Purge Command - Purge the image cache.
• Syntax :
"'^CPR'"
• Variables : None.
• Example :
SEND COMMAND Panel,"'^CPR'"
Purge the image cache.
Panel Streaming Audio Mute Command. Set the audio mute for a specified streaming URL.
• Syntax :
"'^DMM-<audio mute>,<video mute>,<url>'"
• Variables : audio mute - mute/unmute the audio for <url> (0 = unmute, 1 = mute) video mute - mute/unmute the video for <url> (0 = unmute, 1 = mute) ( not implemented at this time ) url - a valid ^SDM url that is already in the playing state.
• Examples :
SEND_COMMAND Panel, "'^DMM-1,0,udp://224.1.1.1:1234'"
Mute audio, unmute video for UDP stream server 224.1.1.1 port 1234.
^EKP
@EKP
SEND_COMMAND Panel, "'^DMM-0,0,udp://224.1.1.1:1234'"
Unmute audio, unmute video for UDP stream server 224.1.1.1 port 1234.
System Extended Keypad - Brings up system extended keypad. Currently, the ’system extended keypad’ and the ’system telephone keypad’ are the same, and have all the keys that the G4 extended keypad had except the ":" key. When the user presses the "Done" button, a string is returned to the master with the user-entered value. The keypad can be removed
either by the Back button or the "^AKR" command ( page 88 ).
Note: The '@EKP' command is implemented for G4 compatibility.
• Syntax :
"'^EKP-[optional initial text];[optional prompt text];[optional hint text];
[optional return prefix];[optional return port]'" or
"'@EKP-[optional initial text];[optional prompt text];[optional hint text];
[optional return prefix];[optional return port]'"
• Variables :
Initial text : Pre-populated text to appear on keypad (i.e. default)
Prompt text : Descriptive header to appear above keypad text entry box
Hint Text : Hint text to appear behind the keypad text entry box
Return prefix : Prefix to the send string returned to the master. If not specified, the entered text will be preceded by
"EKP-".
Return port : The port number to return the response on if different than the port to which the command is sent.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 91
Programming - Send Commands
Panel Commands (Cont.)
^ENC
?ENC
^GCE
Set Text Encoding Method - Sets the text encoding method which is used for commands and strings sent from panel to master (the default is UTF-8).
• Syntax :
"'^ENC-<Encoding>'"
• Variable :
Encoding : 0: UTF-8 (default), 1: Latin-1 (ISO 8859-1)
• Example :
SEND_COMMAND Panel,"'^ENC-1'"
Sets the encoding method used for all strings to the Master to Latin-1.
Note: NetLinx Studio does not support UTF-8 at this time; therefore UTF-8-encoded characters cannot be copied from TPD5 and pasted in Studio. To use NetLinx Studio to send UTF-8 encoded text, byte values must be enumerated in the command.
For example, the following command sends a UTF-8 string to the panel, consisting of ASCII, extended ASCII and Unicode
(Chinese) characters:
"'^UTF-3,0,Hello',$C3,$A2,$C3,$A3,$E5,$9C,$B0,$E7,$9B,$A4,$E3,$83,$87"
Also note that in backwards compatibility mode (i.e. when the ^TXT command is sent or when the ^ENC-1 command has been sent), ISO-8859-1 is used for character encoding/decoding, since that is what G4 panels used. ISO-8859-1 is different from the Windows-1252 character set in that characters in the range 128-159 (decimal) are non-printable control characters.
So in response to a ?TXT query, any characters in that range (assuming the ^ENC-1 was previously sent) will be returned as
AMX Hex quad-encoded values with Custom Event Flag=1, whereas the remainder of the extended ASCII range (160-255)
Get Text Encoding Method - Gets the current text encoding method which is used for commands and strings sent from panel to master (the default is UTF-8).
• Syntax :
"'?ENC'"
• Variables : None
• Example :
SEND_COMMAND Panel,"'?ENC'"
Get the panel's text encoding status. The response returned is a custom event with the following syntax:
Custom Event Property Value
Port port command was received on
ID 0
Type 1331
Flag 0
Value 1 encoding (0 = UTF-8, 1 = ISO-8859-1)
Value 2 0
Value 3 0
Text String that represents the encoding name
• Example response for encoding status :
Custom Event Property Value
Port port command was received on
ID 0
Type 1331
Flag 0
Value 1 0
Value 2 0
Value 3 0
Text UTF-8
Set Gesture Custom Event - Sets whether or not the panel sends a custom event to the master whenever a gesture is detected.
• Syntax :
"'^GCE-<state>'"
• Variables : state: ON or OFF / 1 or 0 / on or off.
Note: This setting is not retained and the default is to always NOT send the events. To enable sending the event, the value after the dash can be "on", "ON", or "1". Anything else will disable sending custom events.
• Examples :
SEND_COMMAND Panel, "'^GCE-on'"
Enables gesture custom event reporting to the master.
SEND_COMMAND Panel, "'^GCE-0'"
Disables gesture custom event reporting to the master.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 92
Programming - Send Commands
Panel Commands (Cont.)
LEVON
LEVOF
?MAC
^MSG
Level on command (generated by NetLinx master) - Enable device to send level changes to the master. By default, devices will not report level changes unless a LEVON command is received. The LEVON command is automatically sent by the master to the device if:
There is a LEVEL event for the DPS of the device.
There is a CREATE_LEVEL defined in the NetLinx program for the DPS of the device.
• Syntax :
"'LEVON'"
• Variables : None
Level off command (generated by NetLinx master) - Disable the device from sending level changes to the master. By default, devices will not report level changes unless a LEVON command is received. The LEVON command is automatically sent by the master to the device if:
There is a LEVEL event for the DPS of the device.
There is a CREATE_LEVEL defined in the NetLinx program for the DPS of the device.
• Syntax :
"'LEVOF'"
• Variables : None
Query Panel MAC Address - Query the MAC Address of the panel.
• Syntax :
"'?MAC'"
• Variables : None
• Example :
SEND_COMMAND Panel,"'?MAC'"
Get the panel's MAC Address. The response returned is a custom event with the following syntax:
Custom Event Property Value
Port port command was received on
ID 0
Type 1315
Flag 0
Value 1 0
Value 2 0
Value 3 0
Text String that represents the MAC Address
• Example response :
Custom Event Property Value
Port port command was received on
ID 0
Type 1315
Flag 0
Value 1 0
Value 2 0
Value 3 0
Text 00:60:9f:90:00:01
Message Dialog Command - A generic message dialog that has displayed content defined from the ^MSG command.
• Syntax :
'^MSG-dialog_id[:dialog_theme],dialog_type[-input_option][:dialog_image_name], timeout, custom_event_type, custom_event_id, title_text, message_text, positive_button_text, negative_button_text, neutral_button_text, cancel_text, timeout_text'
• Variables : dialog_id : Unique id to reference the dialog. Used to track IDs to displayed dialogs.
dialog_theme : Optional theme of the dialog is set by appending the theme to the dialog_id number with ':' and the theme. Valid themes are light and dark (default) dialog_type. The type of dialog to display: std - standard dialog. By default, no image is displayed in the title area.
warn - warning dialog. The built-in warning image is used in the title area.
error - error dialog. The built-in error image is used in the title area.
quest - question dialog. The built-in question image is used in the title area.
list - list of items to choose. By default, no image is displayed in the title area. List items are put in the message_text field and are separated by colons (':').
input - input entry. By default, no image is displayed in the title area.
Optional input_options follow a dash ('-') and are: no option present - alphanumeric input num - numeric input (no alphabetic input) phone - phone pad presented uri - URI keyboard presented email - Email keyboard presented name - Keyboard presented and capital words are used.
date - Date pad presented time - Time pad presented datetime - Date/Time pad presented
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 93
Programming - Send Commands
Panel Commands (Cont.)
^MSG
(Cont.) pass - password entry. By default, no image is displayed in the title area. Optional input_options follow a dash
('-') and are: no option present - alphanumeric input num - numeric input (no alphabetic input) dialog_image_name : It is optional to override any type with a custom image or dynamic image from the TP5 file to be displayed in the title area. The image used is set by appending a ':' and image file/resource name to the dialog_type input_option (e.g. std:number.png or warn:mywarningimage.jpg).
timeout: Timeout is in milliseconds. If timeout is 0, message does not timeout and is considered modal.
custom_event_type : The custom event type value to use for result custom events.
custom_event_id : The custom event ID value to use for result custom events.
title_text : Text that is displayed in the dialog title. If this field is empty, no title is displayed on the dialog.
message_text : In most cases, the contents of this field is displayed in the message of the dialog. There are a few exceptions based on dialog_type: list - In a list dialog type, the message_text contains the list items. List items are separated by a colon (':').
input - In a input dialog type, the message_text contains the initial value of the text entry field of the dialog.
pass In a pass dialog type, the message_text contains the initial value of the text entry field of the dialog.
positive_button_text : Text to display on the positive button (e.g. Yes, OK, Enter, etc.) In most cases, if the positive button is selected, this text is sent to master in the custom.text field. Note: If this field is empty, the positive button is not displayed in the MessageDialog.
Note: Text fields can be put into quotations (“ ”) so that commas can be used in text. Like the CSV parser, if a " is needed in the text, the " can be escaped by a prepended another " (e.g. "").
Note: The use of text params in command instead of preset definitions for button text is so that the language of text can be set in code. Unicode quads for text are supported by using the command '^MSGU-' command. Legacy
ISO-8859-1 (like ^TXT) text is supported by using the '^MSGT-' command.
• Response Data:
The response to the MessageDialog is sent to the master via a Custom Event. Some of the custom event values are set in the ^MSG command, and others are generated as a result of the dialog action.
Result Custom Events data: custom.type: The value set in the custom_event_type field custom.id: The value set in the custom_event_id field.
custom.flag: value has the result. In most cases, it indicates which button was selected, or cancel, or timeout:
-1 = timeout
0 = cancel
1 = positive button
2 = negative button
3 = neutral button
In a list dialog type, when an item is selected, the custom.flag field will be set to 1 (positive button).
custom.value1 The dialog_id value set in the command custom.value2 In a list dialog type, this field has the index of the selected list item. If the first item was selected then value2==1, second item selected then value2==2, etc. If the dialog_type is not a list, then value2 is unused and is set to 0.
custom.value3: Unused. Set to 0.
custom.text: The text of the resulting button selected, or cancel_text if dialog was canceled, or timeout_text if timed out. In list mode, the selected list item text value is sent in this field. In input or pass, the entered value is sent in this field.
Note: Custom events are returned on the port the command was sent to from the master.
• Examples :
SEND_COMMAND Panel,’^MSG-1,std,60000,32001,1,Please Wait,”System is busy”,OK’;
Display dialog ID 1 as a standard dialog.
The timeout is 60s.
The custom_event_type to use is 32001.
The custom_event_id to use is 1.
The title_text is 'Please Wait'.
The message_text is 'System is busy'.
The positive_button_text is 'OK'
SEND_COMMAND Panel,'^MSG-1,list:question-flat-48x48.png,30000,32001,10, Select item,"item 1: item 2:item 3:item 4:item 5",,"Cancel"'
Display dialog ID 1 as a list dialog. The image 'question-flat-48x48.png' is used as the image in the title area.
The timeout is 30s.
The custom_event_type to use is 32001.
The custom_event_id to use is 10.
The title_text is 'Select Item'.
The message_text is list of 5 items (item 1, item 2, item 3, item 4, item5).
The positive_button_text is empty.
The negative_button_text is empty.
The neutral_button_text is 'Cancel'.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 94
Programming - Send Commands
Panel Commands (Cont.)
^MSG
(Cont.)
^MUT
?MUT
^NOT
SEND_COMMAND Panel,"'^MSGT-1:light,error,30000,32001,32002,"Error Title","Lorem ipsum dolor sit amet, consectetur adipiscing elit,sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum. ""the end"","Positive","Negative",
"Neutral","Cancel","Timeout"'"
^MSGT -
The dialog text is encoded in the ISO-8859-1 (Latin-1) format (like what is expected by ^TXT command).
Display dialog ID 1 with a light theme as an error dialog. The default error image is used as the image in the title area.
The timeout is 30s.
The custom_event_type to use is 32001.
The custom_event_id to use is 32001.
The title_text is 'Error Title'.
The message_text is a variation of 'Lorem ipsum...'.
The positive_button_text is 'Positive'.
The negative_button_text is 'Negative'.
The neutral_button_text is 'Neutral'.
The cancel_text is 'Cancel'.
The timeout_text is 'Timeout'.
Panel Volume Mute - Mute or unmute a panel volume.
• Syntax :
"'^MUT-<mute value>'"
• Variables : mute value : 0 for not muted, 1 for muted.
• Examples :
SEND_COMMAND Panel,"'^MUT-1'"
Mute the master volume.
SEND_COMMAND Panel,"'^MUT-0'"
Unmute the master volume.
Query Panel Mute Status - Query the mute status of the panel.
• Syntax :
"'?MUT'"
• Variables : None
• Example :
SEND_COMMAND Panel,"'?MUT'"
Get the panel's mute status. The response returned is a custom event with the following syntax:
Custom Event Property Value
Port port command was received on
ID 0
Type 1305
Flag 0
Value 1 mute status (0 unmuted or 1 for muted)
Value 2 0
Value 3 0
Text String that represents the mute status (0 or 1)
• Example response for muted status :
Custom Event Property Value
Port port command was received on
ID 0
Type 1305
Flag 0
Value 1 1
Value 2 0
Value 3 0
Text 1
Popup Note Command - A generic popup note message that can be used to display information for a short duration on the display.
• Syntax :
'^NOT-note_text, duration, location, text_size'
• Variables : note_text - The text to displayed in the popup note.
duration - The time in milliseconds to display the popup note location - Where to display the popup note. Options are 'c' for CENTERED on display, 't' for TOP CENTER on display, and
'b' for BOTTOM CENTER on display. Any other value will be displayed as CENTER.
text_size - The size value to display the popup note text. Default is 18.
Note: The note text field can be put into quotations (“ ”) so that commas can be used in text. Like the CSV parser, if a " is needed in the text, the " can be escaped by a perpending another " (e.g. ""). Note text is assumed to be UTF-8 encoded.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 95
Programming - Send Commands
Panel Commands (Cont.)
^PKB
@PKB
PKEYB
^PKP
@PKP
PKEYP
^RPP
^RSS
RXON
Show System Private Keyboard Command - Brings up system private keyboard (the same as the system keyboard, with typed text hidden with the '*' character). When user presses the "Done" button, a string is returned to the master with the user-entered value. The keyboard can be removed either by the Back button or the "^AKR" command (
). The
'@PKB' and 'PKEYB' commands are implemented for G4 compatibility.
• Syntax :
"'^PKB-<initial text>;<prompt text>;<hint text>;<return prefix>;<return port>'" or
"'@PKB-<initial text>;<prompt text>;<hint text>;<return prefix>;<return port>'" or
"'PKEYB-<initial text>;<prompt text>;<hint text>;<return prefix>;<return port>'"
• Variables :
Initial text - Pre-populated text to appear on keyboard (i.e. default). Note that for the private keyboard, this text will be hidden.
Prompt text - Descriptive header to appear above keyboard text entry box
Hint Text - Hint text to appear behind the keyboard text entry box
Return prefix - Prefix to the send string returned to the master. If not specified, the entered text will be preceded by
"PKB-".
Return port - The port number to return the response on if different than the port to which the command is sent.
Show System Private Keypad Command - Brings up system private keypad (the same as the system keypad, with typed text hidden with the '*' character). When user presses the "Done" button, a string is returned to the master with the userentered value. The keypad can be removed either by the Back button or the "^AKR" command (
. The '@PKP' and
'PKEYP' commands are implemented for G4 compatibility.
• Syntax :
"'PKEYP-[optional initial text];[optional prompt text];[optional hint text];
[optionalreturn prefix];[optional return port]'"
• Variables :
Initial text : Pre-populated text to appear on keypad (1 - 50 ASCII characters). Note that for the private keypad, this text will be hidden.
Prompt text : Descriptive header to appear above keypad text entry box
Hint Text : Hint text to appear behind the keypad text entry box
Return prefix : Prefix to the send string returned to the master. If not specified, the entered text will be preceded by
"PKP-".
Return port : The port number to return the response on if different than the port to which the command is sent.
• Example :
SEND COMMAND Panel,"'PKEYP-123456789'"
Pops up the Keypad and initializes the text string '123456789' in '*'.
Reset protected password command - This command is used to reset the protected setup password to the factory default value.
• Syntax :
"'^RPP'"
• Variables : None
• Example :
SEND_COMMAND Panel,"'^RPP'"
Reset the panel protected password to the factory default.
Reset System Settings Command - Reset Settings to factory default.
• Syntax :
"'^RSS'"
• Variables : None
• Example :
SEND_COMMAND Panel, "'^RSS'"
Reset the panel to factory default settings.
Send string on command (generated by NetLinx master) - Enable device to send STRING changes to the master. By default, devices will not report STRING changes unless a RXON command is received. The RXON command is automatically sent by the master to the device if:
There is a DATA/STRING event for the DPS of the device.
There is a CREATE_BUFFER defined in the NetLinx program for the DPS of the device.
• Syntax :
"'RXON'"
• Variables : None
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 96
Programming - Send Commands
Panel Commands (Cont.)
RXOF
SHAR
Send string off command (generated by NetLinx master) - Disable the device from sending STRING changes to the master.
By default, devices will not report STRING changes unless a RXON command is received. The RXON command is automatically sent by the master to the device if:
There is a DATA/STRING event for the DPS of the device.
There is a CREATE_BUFFER defined in the NetLinx program for the DPS of the device.
• Syntax :
"'RXOF'"
• Variables : None
Content Sharing command - Send a content URI to be shared. Allows the user to specify a URI to share.
• Syntax :
"'SHAR-<mode>,<uri>'"
• Variables : mode : The mode to use with the URI for sharing uri : The URI to share
• Example :
SEND_COMMAND Panel,"'SHAR-view,udp://255.255.22.25'"
Share the streaming video URI of udp://255.255.25.25 for the Content Sharing receiver to view.
SHUTDOWN Power Off the Panel Command - Receipt of this command will cause the panel to power off.
• Syntax :
"'SHUTDOWN'"
• Variables : None
^SCO Session clear out command - Clears session data for some applications ( Browser, Firefox, Gallery, Skype, Dropbox, VNC server, PlanMaker, TextMaker, and Presentations).
• Syntax:
'^SCO'
• Variables : none
^SLP
SLEEP
Panel Sleep Command - Place the panel in sleep state. Sleep state turns the display off. The 'SLEEP' command is implemented for G4 compatibility.
• Syntax :
"'^SLP'" or
"'SLEEP'"
• Variables : None
• Example :
SEND COMMAND Panel,"'^SLP'"
Sends the panel to the sleep (display off)
^SOU
@SOU
^SSL
@SSL
Play Sound Command - Plays a specified sound file. The '@SOU' command is implemented for G4 compatibility.
• Syntax :
"'^SOU-<sound name>'"
• Variables : sound name : Name of the sound file. Supported sound file formats are: WAV & MP3.
• Example:
SEND COMMAND Panel,"'^SOU-Music.wav'"
Plays the ' Music.wav
' file.
Set the Sleep String Command - Set the content of the string that is sent to the master when the panel goes to sleep
(display off). The '@SSL' command is implemented for G4 compatibility.
• Syntax :
"'^SSL-<sleep string>'" or
"'@SSL-<sleep string>'"
• Variables :
Sleep string : The string sent to the master when the panel goes to sleep.
• Example :
SEND COMMAND Panel,"'^SSL-Sleeping…'"
Sets the sleep string to ' Sleeping… '.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 97
Programming - Send Commands
Panel Commands (Cont.)
^STP
SETUP
^SWK
@SWK
^TKP
@TKP
^TPF
TPAGEOF
^TPN
TPAGEON
Settings application command - Open the Settings Applications. The 'SETUP' command is implemented for G4 compatibility.
• Syntax :
"'^STP'" or
"'SETUP'"
• Variables : None
• Example :
SEND COMMAND Panel,"'^STP'"
Opens the Settings application.
Set the Wake String Command - Set the content of the string that is sent to the master when the panel wakes up from sleep (display on). The '@SWK' command is implemented for G4 compatibility.
• Syntax :
"'^SWK-<wake string>'" or
"'@SWK-<wake string>'"
• Variables :
Wake string : The string sent to the master when the panel wakes up from sleep.
• Example :
SEND COMMAND Panel,"'^SWK-Wakeing Up…'"
Sets the sleep string to ' Wakeing Up… '.
Brings up system telephone keypad - Currently, these keypads are the same, and have all the keys that the G4 extended keypad had except the ":" key. When user presses the "Done" button, a string is returned to the master with the user-
command is implemented for G4 compatibility.
• Syntax :
"^TKP-[optional initial text];[optional prompt text];[optional hint text];
[optional return prefix];[optional return port]'"
• Variables :
Initial text : Pre-populated text to appear on keypad (i.e. default)
Prompt text : Descriptive header to appear above keypad text entry box
Hint Text : Hint text to appear behind the keypad text entry box
Return prefix : Prefix to the send string returned to the master. If not specified, the entered text will be preceded by
"TKP-".
Return port : The port number to return the response on if different than the port to which the command is sent.
Note: See also - ^EKP (system telephone keypad) on page 91.
Turn Off Page Tracking Command. The 'TPAGEOF' command is implemented for G4 compatibility.
• Syntax :
"'^TPF'" or
"'TPAGEOF'"
• Variables : None
• Example :
SEND COMMAND Panel,"'^TPF'"
Turn On Page Tracking Command - This command turns on page tracking, whereby when the page or popups change, a string is sent to the Master. This string may be captured with a CREATE_BUFFER command for one panel and sent directly to another panel. The 'TPAGEON' command is implemented for G4 compatibility.
• Syntax :
"'^TPN'" or
"'TPAGEON'"
• Variables : None
• Example :
SEND COMMAND Panel,"'^TPN'"
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 98
Programming - Send Commands
Panel Commands (Cont.)
^UPD
UPDATE
^VKB
@VKB
^VKP
@VKP
^VKS
^VOL
Panel Update Command - This command starts the Update Manager to perform a silent update of platform applications or firmware. The 'UPDATE' command is implemented for G4 compatibility.
Note: Allow 10-15 minutes for update to complete before sending another ^UPD command .
• Syntax :
"'^UPD-<update type>'" or
"'UPDATE-<update type>'"
• Variables : update type: Determines which form of update is performed. Valid values are APP and FW.
• Examples :
SEND_COMMAND Panel,"'^UPD-FW'"
Update the panels Firmware silently in the background.
SEND_COMMAND Panel,"'^UPD-APP'"
Update the panels applications silently in the background.
Show Virtual Keyboard Command - Brings up system virtual keyboard, which is the keyboard without a designated text entry area. A Text Input button must be in focus; if not, the keyboard will not appear. The type of keyboard is determined by the Text Area currently in focus. When user presses the "Done" button, a string is returned to the master with the user-
entered value. The keyboard can be removed either by the Back button or the "^AKR" command ( page 88
). The '@VKB' command is implemented for G4 compatibility.
• Syntax :
"'^VKB'"
• Variables : None
Show Virtual Keypad Command - Brings up system virtual keypad, which is the keypad without a designated text entry area. A Text Input button must be in focus; if not, the keypad will not appear. The type of keypad is determined by the Text
Area currently in focus. When user presses the "Done" button, a string is returned to the master with the user-entered value. The keypad can be removed either by the Back button or the "^AKR" command (
). The '@VKP' command is implemented for G4 compatibility.
• Syntax :
"'^VKP'"
• Variables : None
Virtual Key Stroke Command - Sends a Virtual Key Stroke to the Modero X G5 touch panel.
Note: this command does not function in the same way as with G4 touch panels.
Syntax :
"'^VKS-<keycode>'"
Variable : keycode : Android key code decimal value. Note that these are not the same as in G4.
Note: For the key code values, please refer to the Virtual Keystroke Commands table on page 169.
Set Volume Command - Set the [specified] volume.
• Syntax :
"'^VOL,<level>,[optional type]'"
Variables :
Level : the volume level from 0-100. The level will be scaled according to the platforms abilities.
Type (option) : Change the volume of the given type
0 = Master volume (change all volumes simultaneously). Used by default if no type is specified. This is not a real volume, but instead is a virtual value that changes all other volume type concurrently.
10 = Alarm Volume
11 = Call Volume
12 = Media Volume
13 = Notification Volume
44 = Display the volume dialog (level is ignored)
Note: the platform dialog sliders will NOT update if they are displayed when the command is received. They are accurate, however, if displayed after receiving the command.
• Examples :
SEND_COMMAND Panel,"'^VOL,50'"
Sets the master volume to 50.
SEND_COMMAND Panel,"'^VOL,50,0'"
Sets the master volume to 50.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 99
Programming - Send Commands
Panel Commands (Cont.)
?VOL
^WCN
WEBU
^WKE
WAKE
Query Volume Command - Query the volume.
• Syntax :
"'?VOL,[optional type]'"
• Variables :
Type (option) Get the volume of the given type
0 = Master volume. Used by default if no type is specified. Since Master volume is not a real volume, the value returned will actually be the Media Volume Value.
10 = Alarm Volume
11 = Call Volume
12 = Media Volume
13 = Notification Volume
The response returned is a custom event with the following syntax:
Custom Event Property Value
Port port command was received on
ID 0
Type 1306
Flag 0
Value 1 volume level
Value 2 volume type
Value 3 0
Text String containing 'type=level'
• Examples :
SEND_COMMAND Panel,"'?VOL'"
Query the Master volume. Response would be similar to:
Custom Event Property Value
Port port command was received on
ID 0
Type 1306
Flag 0
Value 1 80
Value 2 0
Value 3 0
Text Master=80
SEND_COMMAND Panel,"'?VOL,10'"
Query the Alarm volume. Response would be similar to:
Custom Event Property Value
Port port command was received on
ID 0
Type 1306
Flag 0
Value 1 20
Value 2 10
Value 3 0
Text Media=72
Web Control Name (Panel to Master) - Report the Web Control (VNC) name to the master.
This is originated in the panel and sent to the master if VNC is enabled.
Update Firmware from URL - This command tells the panel to retrieve a firmware kit file from the included URL and update to the firmware included in that kit file.
• Syntax :
"'WEBU-<url>'"
• Variable : url : URL to the kit file. Support protocols are HTTP only at this time.
• Example :
SEND_COMMAND PANEL,"'WEBU,http://file.server/MODEROX-G5-firmware.kit'"
Download and install the MODEROX-G5-firmware.kit file from the HTTP server file.server.
Panel Wakeup Command - Place the panel in wake state. Wake state turns the display on. The 'WAKE' command is implemented for G4 compatibility.
• Syntax :
"'^WKE'"
• Variables : None
• Example :
SEND COMMAND Panel,"'^WKE'"
Wakes the panel from sleep (turn display on)
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 100
Programming - Send Commands
Page Commands
Page Commands are case-insensitive.
Page Commands
^AFP Flip to specified page using the named animation.
• Syntax :
"'^AFP-<page name>,<animation>,<origin>,<duration>'"
• Variables :
Page Name : If the page name is blank, flip the to the previous page
Animation : If blank/invalid, the default animation is Fade .
Animation Name Command Syntax* (see note below) Origin(s)
^PCL
^PCT
Center Door Fade
Door Fade
Fade
Slide
Slide Bounce
Spin In
Spin Out cntrdrfade, centerdoorfade, or center door fade top(2), bottom(3), left(4), right(5) doorfade, door fade, or door fade slide top(2), bottom(3), left(4), right(5) center(1) top(2), bottom(3), left(4), right(5) sldbounce, slidebounce, or slide bounce spinin or spin in spinout or spin out top(2), bottom(3), left(4), right(5) center(1) center(1)
Default Origin right(5) right(5) center(1) right(5) right(5) center(1) center(1)
Zoom In
Zoom Out zoomin or zoom in zoomout or zoom out center(1) center(1) center(1) center(1)
Note: Multiple aliases for the transition name command syntax are allowed to maintain backwards compatibility with G4.
Duration : Transition time in 10ths of a second. Range is 3-30 with 15 (1.5 seconds) as the default
• Examples :
SEND_COMMAND Panel,"'^AFP-NextPage,slide,4,5'"
Flip to NextPage sliding from the left for half a second.
SEND_COMMAND Panel,"'^AFP-,centerdoorfade,2,10'"
Flip to NextPage center door fade from the top for a second.
Collapse Collapsible Popup Command - Moves the named closeable popup to the collapsed position.
• Syntax :
"'^PCL-<popup name>;[optional target page]'"
• Variables :
Popup name : the name of the popup to collapse
Target page : name of the page hosting the popup to affect the change upon. If target page is not specified, the command is applied to the current page.
• Examples :
SEND_COMMAND Panel,"'^PCL-Contacts'"
Collapse the Contacts popup on the current page.
SEND_COMMAND Panel,"'^PCL-Contacts;Teleconference Control'"
Collapse the Contacts popup on the Teleconference Control page.
Collapsible Popup Custom Toggle Command - This is an advanced "toggle" command for collapsible popups, working with a comma-separated list of commands. This list is parsed and a command table is created. Based on the current state of the collapsible popup, the correct command is executed.
Note: The previously parsed list is saved and is only parsed again if the command string differs for this popup.
• Syntax :
"'^PCT-<popup>,<custom toggle commands>;[optional target page]'"
• Variables :
Popup : popup name
Custom toggle commands : a comma separated list of commands. This list is parsed and a command table is created. The state letters are as follows:
o - open
c - collapsed
d - dynamic, followed by an integer indicating the offset.
* - wildcard, always last in the list
Before and after states are separated by -> characters.
Target page : name of the page hosting the popup to affect the change upon. If target page is not specified, the command is applied to the current page.
• Example :
SEND_COMMAND Panel,"'^PCT-RightSlider,c->o,o->d100,*->c'"
The popup named RightSlider opens if collapsed, move to d100 if open, and collapse otherwise.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 101
Programming - Send Commands
Page Commands (Cont.)
^PDO
^PGE
PAGE
^POP
^PPA
@PPA
Collapsed Popup Dynamic Offset Command - Moves the collapsible popup to a specific offset position relative to the collapsed direction configured for the popup. This allows other positions besides open and collapsed.
• Syntax :
"'^PDO-<popup name>,<offset>;[optional target page]'"
• Variables :
Popup name : name of the popup to affect offset : number of pixels to offset (hide). <offset> is constrained as follows: 0 <= offset <= collapsed offset
Target page : name of the page hosting the popup to affect the change upon. If target page is not specified, the command is applied to the current page.
• Examples :
"'^PDO-RightSlider,66'"
Move popup named RightSlider to an offset position of 66 on the current page.
"'^PDO-RightSlider,66;Media Controls'"
Move popup named RightSlider to an offset position of 66 on the Media Controls page.
Page Flip Command - Flips to a page with a specified page name. If the page is currently active, it will not redraw the page. The
'PAGE' command is implemented for G4 compatibility.
• Syntax :
"'^PGE-<page name>'" or
"'PAGE-<page name>'"
• Variable : page name : Name of the page to be displayed. If left blank, the page flips back to the previous page.
• Examples :
SEND_COMMAND Panel,"'^PGE-Page1'"
Flips to page1.
SEND_COMMAND Panel,"'^PGE-'"
Flips to the previous page.
Open Collapsible Popup Command - Moves the named collapsible popup to the open position.
• Syntax :
"'^POP-<popup>;[optional target page]'"
• Variables :
Popup : the name of the popup to collapse
Target page : name of the page hosting the popup to affect the change upon. If target page is not specified, the command is applied to the current page.
• Examples :
SEND_COMMAND Panel, "'^POP-Contacts'"
Open the Contacts popup on the current page.
SEND_COMMAND Panel, "'^POP-Contacts;Teleconference Control'"
Open the Contacts popup on the Teleconference Control page.
Close All Popups Command - Close all popups on a specified page. The '@PPA' command is implemented for G4 compatibility.
• Syntax :
"'^PPA-<page name>'" or
"'@PPA-<page name>'"
• Variable : page name : Name of the page to close all popups on. If no name is specified, then the current page will have all popups closed.
• Example :
SEND_COMMAND Panel,"'^PPA-Page1'"
Close all pop-ups on Page1.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 102
Programming - Send Commands
Page Commands (Cont.)
^PPF
@PPF
PPOF
^PPG
@PPG
PPOG
^PPK
@PPK
^PPM
@PPM
Popup Page Off Command - Detach a popup from a page. If the page name is empty, the current page is used. If the popup page is part of a group, the whole group is deactivated. This command works in the same way as the 'Hide Popup' command in
TPDesign 5. The '@PPF' and 'PPOF' commands are implemented for G4 compatibility.
• Syntax :
"'^PPF-<popup page name>;[optional page name]'" or
"'@PPF-<popup page name>;[optional page name]'" or
"'PPOF-<popup page name>;[optional page name]'"
• Variables : popup page name : Name of the popup page.
page name : Name of the page the popup is displayed On. If not specified the popup is detached from the current page.
• Examples :
SEND_COMMAND Panel,"'^PPF-Popup1;Main'"
Detach the popup 'Popup1' from page 'Main'.
SEND_COMMAND Panel,"'^PPF-Popup1'"
Detach the popup page 'Popup1' from the current page.
Toggle a Popup Page - Toggle a specific popup page. If the page name is empty, the current page is used. Toggling refers to the activating/deactivating (On/Off) of a popup page. This command works in the same way as the 'Toggle Popup' command in
TPDesign. The '@PPG' and 'PPOG' commands are implemented for G4 compatibility.
• Syntax :
"'^PPG-<popup page name>;[optional page name]'" or
"'@PPG-<popup page name>;[optional page name]'" or
"'PPOG-<popup page name>;[optional page name]'"
• Variables : popup page name : Name of the popup page.
page name : Name of the page the popup is toggled on. If not specified the popup is toggled on the current page.
• Examples :
SEND_COMMAND Panel,"'^PPG-Popup1;Main'"
Toggles the popup page 'Popup1' on the 'Main' page from one state to another (On/Off).
SEND_COMMAND Panel,"'^PPG-Popup1'"
Toggles the popup page 'Popup1' on the current page from one state to another (On/Off).
Kill Popup Page Command - Kill a specific popup page from all pages. Kill refers to the deactivating (Off) of a popup window from all pages. If the pop-up page is part of a group, the whole group is deactivated. This command works in the same way as the 'Clear Group' command in TPDesign. The '@PPK' command is implemented for G4 compatibility.
• Syntax :
"'^PPK-<popup page name>'" or
"'@PPK-<popup page name>'"
• Variables : popup page name : Name of the popup page.
• Example :
SEND_COMMAND Panel,"'^PPK-Popup1'"
Kills the popup page ' Popup1 ' on all pages.
Popup modal command - Set whether a popup is modal or not modal. The '@PPM' command is implemented for G4 compatibility.
• Syntax :
"'^PPM-<popup page name>;<modal 1|0>'" or
"'@PPM-<popup page name>;<moda1 mode 1|0>'"
• Variables : popup page name : Name of the popup page.
modal mode : 1 if modal, 0 if non-modal.
• Example :
SEND_COMMAND Panel,"'^PPM-Popup1;1'"
Set the popup page named Popup1 to modal mode.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 103
Programming - Send Commands
Page Commands (Cont.)
^PPN
@PPN
PPON
^PPT
@PPT
^PPX
@PPX
^PTC
Attach a popup on a page - Attach a specific popup page to launch on either a specified page or the current page. If the page name is empty, the current page is used. If the popup page is already on, do not re-draw it. This command works in the same way as the 'Show Popup' command in TPDesign5. The '@PPN' and 'PPON' commands are implemented for G4 compatibility.
• Syntax :
"'^PPN-<popup page name>;[optional page name]'" or
"'@PPN-<popup page name>;[optional page name]'" or
"'PPON-<popup page name>;[optional page name]'"
• Variables : popup page name : Name of the popup page.
page name : Name of the page the popup is displayed on. If the page name is not specified the current page is used.
• Examples :
SEND_COMMAND Panel,"'^PPN-Popup1;Main'"
Activates 'Popup1' on the 'Main' page.
SEND_COMMAND Panel,"'^PPN-Popup1'"
Activates the popup page ' Popup1 ' on the current page.
Popup Timeout Command - Set the popup to close after timeout. The '@PPT' command is implemented for G4 compatibility.
• Syntax :
"'^PPT-<popup page name>;<timeout>'" or
"'@PPT-<popup page name>;<timeout>'"
• Variables :
Popup page name : the name of the popup to apply the timeout to. Popup must be visible on screen in order to apply timeout
Timeout : the time in tenths of seconds (10 = 1 second) or 0 to cancel timeout.
Note: Successive calls to timeout will reset the timeout. A timeout of 0 cancels the timeout and the popup stays open.
• Example :
SEND_COMMAND Panel,'^PPT-MyPopup;150'
Close MyPopup after 15 seconds.
Close All Popup Pages Command - Close all popups on all pages. This command works in the same way as the 'Clear All' command in TPDesign5. The '@PPX' command is implemented for G4 compatibility.
• Syntax :
"'^PPX'" or
"'@PPX'"
• Variables : None
• Example :
SEND_COMMAND Panel,"'^PPX'"
Close all popups on all pages.
Toggle Collapsible Popup Collapsed Command - Toggles the named collapsible popup between the open and collapsed positions. More specifically, if the popup is not fully collapsed, it is collapsed.
• Syntax :
"'^PTC-<popup>;[optional target page]'"
• Variables :
Popup : the name of the popup to toggle
Target page : name of the page hosting the popup to affect the change upon. If target page is not specified, the command is applied to the current page.
• Examples :
SEND_COMMAND Panel,"'^PTC-Contacts'"
Toggle the Contacts popup collapsed on the current page.
SEND_COMMAND Panel,"'^PTC-Contacts;Teleconference Control'"
Toggle the Contacts popup collapsed on the Teleconference Control page.
Note: Collapsible popup send commands do not automatically show the popup on the target page. The popup must be first shown with a standard show command. This applies even when the collapsible popup is a member of a popup group. For all of these commands, if the target page is blank, the current page is used. If the named popup is not collapsible, the commands are ignored.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 104
Programming - Send Commands
Page Commands (Cont.)
^PTO Toggle Collapsed Popup Open Command - Toggles the named collapsible popup between the open and collapsed positions.
More specifically, if the popup is not fully open, it is opened.
• Syntax :
"'^PTO-<popup>;[optional target page]'"
• Variables :
Popup : the name of the popup to toggle
Target page : name of the page hosting the popup to affect the change upon. If target page is not specified, the command is applied to the current page.
• Examples :
SEND_COMMAND Panel,'^PTO-Contacts'
Toggle the Contacts popup open on the current page.
SEND_COMMAND Panel,'^PTO-Contacts;Teleconference Control'
Toggle the Contacts popup open on the Teleconference Control page.
Note: Collapsible popup send commands do not automatically show the popup on the target page. The popup must be first shown with a standard show command. This applies even when the collapsible popup is a member of a popup group. For all of these commands, if the target page is blank, the current page is used. If the named popup is not collapsible, the commands are ignored.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 105
Programming - Send Commands
Button Commands
Button Commands
^ANI
^APF
Multistate Button Animation Command - Commands a multistate button to animate from a starting state to an ending state.
• Syntax :
^ANI-<addr range>,<start state>,<end state>,<time>
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
start state : Beginning of button state (0= current state).
end state : End of button state.
time : In 1/10 second intervals.
• Example :
SEND_COMMAND Panel,"'^ANI-1,1,10,50'"
Command button with Address 1 to animate from state 1 to state 10 over 5 seconds.
Add page flip action - Add page flip action to a button. This command installs a page flip command to the Button Release event action.
• Syntax :
"'^APF-<addr range>,<page flip action>,<page name> [,<animation>,[origin],[duration]]'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
page flip action : (see the following):
Stan[dardPage] - flip to standard page
StanAni - flip to standard page with animation
PrevAni - flip to previous page with animation
Prev[iousPage] - flip to previous page
Show[Popup] - Show popup page
Hide[Popup] - Hide popup page
Togg[lePopup] - toggle popup state
ClearG[roup] - clear popup page group from all pages
ClearP[age] - clear all popup pages from a page with the specified page name
ClearA[ll] - Clear all popup pages from all pages
Page Name : the name of the page to flip to, or name of popup to show/hide/toggle
Animation : If animated flip, the animation to perform.
Origin : If animated flip, the origin of the animation.
Duration : Transition time in 10ths of a second. Range is 3-30 with 15 (1.5 seconds) as the default
Animation Name
Center Door Fade
Door Fade
Fade
Slide
Slide Bounce
Spin In
Spin Out
Zoom In
Zoom Out
Command Syntax* (see note below) cntrdrfade, centerdoorfade, or center door fade doorfade, door fade, or door fade slide sldbounce, slidebounce, or slide bounce spinin or spin in spinout or spin out zoomin or zoom in zoomout or zoom out
Origin(s) top(2), bottom(3), left(4), right(5) top(2), bottom(3), left(4), right(5) center(1) top(2), bottom(3), left(4), right(5) top(2), bottom(3), left(4), right(5) center(1) center(1) center(1) center(1)
Note: Multiple aliases for the transition name command syntax are allowed to maintain backwards compatibility with G4.
• Example :
SEND COMMAND Panel,"'APF-400,StanAni,Main Page,ZoomIn,30'"
Add animated page flip action to button 400 to flip to Main Page using zoom in for 3 seconds.
Default Origin right(5) right(5) center(1) right(5) right(5) center(1) center(1) center(1) center(1)
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 106
Programming - Send Commands
Button Commands (Cont.)
^BAF
^BAT
^BAU
^BCB
Append UTF-8 Text to State Command - append non-unicode text.
• Syntax :
"'^BAF-<addr range>,<button states range>,<new text>'"
• Variables : address range : Address codes of buttons to affect. A ' .
' between addresses includes the range, and & between addresses includes each address.
button states range: 1 - 256 for multi-state buttons (0 = All states, for general buttons 1 = Off state and 2 = On state).
new text : UTF-8 encoded characters.
• Example :
SEND_COMMAND Panel,"'^BAF-520,1, ξεσκεπάζω τὴν ψυχοφθόρα βδελυγμία '"
Appends the UTF-8 text ' ξεσκεπάζω τ ?
ν ψυχοφθόρα βδελυγμία ' to the button's OFF state.
Append Text to State Command - Append non-unicode text.
• Syntax :
"'^BAT-<addr range>,<button states range>,<new text>'"
Variables : address range: Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for general buttons 1 = Off state and 2 = On state).
new text : ISO-8859-1 encoded characters.
• Example :
SEND_COMMAND Panel,"'^BAT-520,1,Enter City'"
Appends the text 'Enter City' to the button's OFF state.
Append Unicode Text to State Command - Append unicode text. Same format as ^UNI.
• Syntax :
"'^BAU-<addr range>,<button states range>,<unicode text>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and 2 = On state).
unicode text: Unicode characters must be entered in Hex format.
• Example :
SEND_COMMAND Panel,"'^BAU-520,1,00770062'"
Appends Unicode text "00770062" ('wb') to the button's OFF state.
Set Border Color Command - Set the border color to the specified color. Only if the specified border color is not the same as the current color.
• Syntax :
"'^BCB-<addr range>,<button states range>,<color value>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
color value: See color table for more information.
Note: Colors can be set by Color Numbers, Color name, RGB alpha colors (RRGGBBAA) or RGB colors values (RRGGBB). RGBA and
RGB color are given in HEX ASCII prepended by a '#'.
• Examples :
SEND_COMMAND Panel,"'^BCB-500.504&510,1,12'"
Sets the Off state border color to 12 (Yellow).
SEND_COMMAND Panel,"'^BCB-520,2,#FF000080'"
Set the ON state border color to RED with opacity at 128 ($80 / 0x80).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 107
Programming - Send Commands
Button Commands (Cont.)
?BCB
^BCF
Get Border Color Command - Get the current border color.
• Syntax :
"'?BCB-<addr range>,<button states range>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
Value is returned in a custom event with the following properties:
Custom Event Property Value
Port port command was received on
ID Address code of the button responding
Type 1011
Flag 0
Value 1 Button state number
Value 2 Actual length of string (should be 9)
Value 3 0
Text Hex encoded color value (ex: #000000FF)
• Example :
SEND COMMAND Panel,"'?BCB-529,1'"
Gets the button 'OFF state' border color. information. The result sent to the Master would be:
Custom Event Property Value
Port port command was received on
ID 529
Type 1011
Flag 0
Value 1 1
Value 2 9
Value 3 0
Text #222222FF
Background Color Fill Command - Set the background color fill to specified color in state(s).
• Syntax :
"'^BCF-<addr range>,<button state range>,<color value>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
color value
: See the color table on page 165 for details.
Note: Colors can be set by Color Numbers, Color name, RGB alpha colors (RRGGBBAA) or RGB colors values (RRGGBB). RGBA and
RGB color are given in HEX ASCII prepended by a '#'
• Example :
SEND_COMMAND Panel,"'^BCF-500.504&510.515,1,Blue'"
Sets the OFF state background color fill for the buttons with variable text ranges of 500-504 & 510-515 to Blue.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 108
Programming - Send Commands
Button Commands (Cont.)
?BCF
^BCT
?BCT
Get Fill Color Command - Get the current fill color.
• Syntax :
"'?BCF-<addr range>,<button states range>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
Value is returned in a custom event with the following properties:
Custom Event Property Value
Port port command was received on
ID Address code of the button responding
Type 1012
Flag 0
Value 1 Button state number
Value 2 Actual length of string (should be 9)
Value 3 0
Text Hex encoded color value (ex: #000000FF)
• Example :
SEND COMMAND Panel,"'?BCF-529,1'"
Gets the button 'OFF state' fill color information. The result sent to the Master would be:
Custom Event Property Value
Port port command was received on
ID 529
Type 1012
Flag 0
Value 1 1
Value 2 9
Value 3 0
Text #FF8000FF
Set Text Color Command - Set the text color to the specified color.
• Syntax :
"'^BCT-<addr range>,<button states range>,<color value>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
color value:
See the color table on page 165 for details.
Note: Color can be assigned by color name (without spaces), number or R,G,B value (RRGGBB or RRGGBBAA).
• Example :
SEND_COMMAND Panel,"'^BCT-500.504&510,1,12'"
Sets the Off state text color to 12 (Very Light Yellow).
Get Text Color Command - Get the current text color.
• Syntax :
"'?BCT-<addr range>,<button states range>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
Value is returned in a custom event with the following properties:
Custom Event Property Value
Port port command was received on
ID Address code of the button responding
Type 1013
Flag 0
Value 1 Button state number
Value 2 Actual length of string (should be 9)
Value 3 0
Text Hex encoded color value (ex: #000000FF)
• Example :
SEND COMMAND Panel,"'?BCT-529,1'"
Gets the button 'OFF state' text color information. The result sent to Master would be:
Custom Event Property Value
Port 529
ID Address code of the button responding
Type 1013
Flag 0
Value 1 1
Value 2 9
Value 3 0
Text #FFFFEFF
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 109
Programming - Send Commands
Button Commands (Cont.)
^BDC Button Drag and Drop Custom Event Command - This command configures Drag and Drop custom events. This command can be used to enable or disable the transmission of custom events to the master whenever certain operations occur. For example, the system programmer may want to be notified whenever a drag button enters an acceptable target.
The notification mechanism is a custom event. The ^BDC command takes the form of a comma separated list of custom event numbers. If the number is 0 or blank for a given event type then no custom event will be transmitted when that event occurs. If a number is specified, then it is used as the EVENT TYPE value for the custom event. The range of 32001 to 65535 has been reserved in the panel for user custom event numbers. A different value could be used but might collide with other AMX event numbers. Event configuration is not permanent and all event numbers revert to the default of 0 when the panel restarts.
Syntax :
"'^BDC-<drag start event number>,<enter valid drop target event number>,
<exit valid drop target event number>,<drop event number>,<drag cancel event number>,
<enter invalid drop target event number>,<exit invalid drop target event number>
Variables :
• drag start event number: Value of a drag start event
• enter valid drop target event number: Value of an enter valid drop target event.
• exit valid drop target event number: Value of an exit valid drop target event.
• drop event number : Value of a drop event
• drag cancel event number : Value of a drag cancel event
• enter invalid drop target event number : Value of an enter invalid drop target event.
• exit invalid drop target event number: Value of an exit invalid drop target event.
By default the ^BDC command is enabled , the default values are:
• DragStartedEvent = 1410
• ValidDropEnterEvent = 1411
• ValidDropExitEvent = 1412
• DropEvent = 1413
• DragCancelEvent = 1414
• InvalidDropEnterEvent = 1415 ;
• InvalidDropExitEvent = 1416
To disable the ^BDC command send: ^BDC-0,0,0,0,0,0,0
The events are:
• DragStarted - a draggable button has initiated a drag
• ValidDropEntered - a draggable button has entered a valid target
• ValidDropExited - a draggable button has exited a valid target
• Drop - a draggable button has been dropped on a valid target
• DragCancel - a draggable button has been dropped outside of a valid target
• InvalidDropEntered - a draggable button has entered an invalid target
• InvalidDropExited - a draggable button has exited an invalid target
In response to any or all of the above events, the panel will create a custom event which is then sent to the master.
The format of START custom events transmitted to the master are as follows:
CUSTOM.TYPE = the specified drag event custom event type (started)
CUSTOM.ID = the address of the viewer button which generated the event
CUSTOM.FLAG = 0
CUSTOM.VALUE1 = the button address of the draggable
CUSTOM.VALUE2 = 0
CUSTOM.VALUE3 = 0
CUSTOM.TEXT =
'dr{ch=<channelPort>,<channel>:ad=<addressPort>,<address>:gp=<groupName>:nm=<buttonName>}
dt{vl=<dropTargetValid 1=valid,0=invalid>:ch=<channelPort>,<channel>:ad=<addressPort>,
<address>:nm=<buttonName>}…
dt{vl=<dropTargetValid 1=valid,0=invalid>:ch=<channelPort>,<channel>:ad=<addressPort>,
<address>:nm=<buttonName>}'
The CUSTOM.TEXT provides data sets that represent the draggable's info (dr). The draggable's info included is the drag channel port, the drag channel code, the drag address port, the drag address code, the drag group name, and the drag button name.
Drag target info is also presented, with a data set for each drag target visible at that time. The drag targets info (dt) includes the target validity to accept the drop, the drop target channel port, the drop target channel code, the drop target address port, the drop target address code, and the drop target button name.
• Buttons are identified as dr (draggable) or dt (drop target)
• Button properties are contained between open brace ( { ) and close brace ( } )
• Button properties are represented by key=value pairs (KVP).
• Keys are two letters followed by equal ( = ) by convention but the two letter keys are not a requirement.
• Property KVPs are separated by colon ( : ).
• Each Button's data sets are on a separate line (i.e. the close brace is followed by a \n).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 110
Programming - Send Commands
Button Commands (Cont.)
^BDC
(Cont.)
Key values
• dr = draggable
• ch = channel (port,channel)
• ad = address (port,address)
• gp = group name
• nm = button name
• dt = drop target
• vl = validity of drop target (valid=1, invalid=0)
• ch = channel (port,channel)
• ad = address (port,address)
• nm = button name
Example texts: dr{ch=1,31:ad=1,31:gp=:nm=Drag1} dt{vl=1:ch=1,101:ad=1,101:nm=Tgt1} dt{vl=1:ch=3,103:ad=3,103:nm=Tgt3} dt{vl=1:ch=3,103:ad=3,103:nm=Tgt3} dt{vl=0:ch=1,11:ad=1,11:nm=Grp1 Tgt1} dt{vl=0:ch=1,12:ad=1,12:nm=Grp1 Tgt2} dt{vl=0:ch=2,11:ad=2,11:nm=Grp2 Tgt1} dt{vl=0:ch=1,15:ad=1,15:nm=Grp1 Tgt5} dt{vl=0:ch=1,16:ad=1,16:nm=Grp1 Tgt6} dt{vl=0:ch=2,13:ad=2,13:nm=Grp2 Tgt3} dt{vl=0:ch=1,15:ad=1,15:nm=Grp1 Tgt5} dt{vl=0:ch=1,16:ad=1,16:nm=Grp1 Tgt6} dt{vl=0:ch=2,13:ad=2,13:nm=Grp2 Tgt3} dr{ch=2,4:ad=2,4:gp=Group1+2:nm=Drag2_4} dt{vl=1:ch=1,11:ad=1,11:nm=Grp1 Tgt1} dt{vl=1:ch=1,12:ad=1,12:nm=Grp1 Tgt2} dt{vl=1:ch=2,11:ad=2,11:nm=Grp2 Tgt1} dt{vl=1:ch=1,15:ad=1,15:nm=Grp1 Tgt5} dt{vl=1:ch=1,16:ad=1,16:nm=Grp1 Tgt6} dt{vl=1:ch=2,13:ad=2,13:nm=Grp2 Tgt3} dt{vl=1:ch=1,15:ad=1,15:nm=Grp1 Tgt5} dt{vl=1:ch=1,16:ad=1,16:nm=Grp1 Tgt6} dt{vl=1:ch=2,13:ad=2,13:nm=Grp2 Tgt3} dt{vl=0:ch=1,101:ad=1,101:nm=Tgt1} dt{vl=0:ch=3,103:ad=3,103:nm=Tgt3} dt{vl=0:ch=3,103:ad=3,103:nm=Tgt3}
The format of VALIDENTER/VALIDEXIT/CANCEL custom events transmitted to the master are as follows:
CUSTOM.TYPE = the specified drag event (validEntered/validExited/drop/cancel)
CUSTOM.ID = the address of the drag/drop button which generated the event
CUSTOM.FLAG = 0 // 0 specifies valid
CUSTOM.VALUE1 = the button address of the draggable
CUSTOM.VALUE2 = 0
CUSTOM.VALUE3 = 0
CUSTOM.TEXT = ""
The format of INVALIDENTER/INVALIDEXIT custom events transmitted to the master are as follows:
CUSTOM.TYPE = the specified drag event (invalidEntered/invalidExited)
CUSTOM.ID = the address of the drag/drop button which generated the event
CUSTOM.FLAG = 65535 (-1) // -1 specifies invalid target
CUSTOM.VALUE1 = the button address of the draggable
CUSTOM.VALUE2 = 0
CUSTOM.VALUE3 = 0
CUSTOM.TEXT = ""
If the VALIDENTER and INVALIDENTER events are set to the same event number, the flag value indicates whether the targets are valid or not. 0 == valid, 65535 (-1) == invalid.
If the VALIDEXIT and INVALIDEXIT events are set to the same event number, the flag value indicates whether the targets are valid or not. 0 == valid, 65535 (-1) == invalid.
The format of the DROP custom event transmitted to the master is as follows:
CUSTOM.TYPE = the specified drag event (started/entered/exited/drop/cancel) the address of the
viewer button which generated the event
CUSTOM.ID = the address of the viewer button which generated the event
CUSTOM.FLAG = 0
CUSTOM.VALUE1 = the button address of the draggable
CUSTOM.VALUE2 = the button address of the dropTarget
CUSTOM.VALUE3 = 0
CUSTOM.TEXT = group name to which the dropTarget belongs
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 111
Programming - Send Commands
Button Commands (Cont.)
^BDC
(Cont.)
?BDC
^BFB
^BIM
• Example :
SEND_COMMAND panel,"'^BDC-32001,32002,32003,32004,32005'"
After the users sends this command to the panel, if the user then drags a button addressed 9 and then proceeds to drop that draggable button on a dropTarget button addressed 10, the following event would be transmitted to the master.
CUSTOM.ID = 10 (the dropTarget receives the drop event)
CUSTOM.TYPE = 32004 (this our drop event)
CUSTOM.FLAG = 0
CUSTOM.VALUE1 = 9 (the button we dragged over the target & dropped)
CUSTOM.VALUE2 = 10 (the dropTarget that the draggable was dropped on)
CUSTOM.VALUE3 = 0
CUSTOM.TEXT = "" (a name we had given to the group the target was assigned,since the target was
not assigned to a group we'll receive an empty string)
Query Button Drag and Drop Custom Event Command - Get the drag and drop custom event values.
• Syntax :
"'?BDC'"
• Variables : None
The response returned is a custom event with the following syntax:
CUSTOM.TYPE = 0
CUSTOM.ID = 1332
CUSTOM.FLAG = 0
CUSTOM.VALUE1 = 0
CUSTOM.VALUE2 = 0
CUSTOM.VALUE3 = 0
CUSTOM.TEXT = String containing a comma separated list of Button Drag & Drop Custom Event values
'[StartEventNum],[ValidEnterEventNum],[ValidExitEventNum],[DropEventNum],[CancelEventNum],
[InvalidEnterEventNum],[InvalidExitEventNum]'
• Example :
SEND_COMMAND Panel,"'?BDC'"
Query the Master Button Drag and Drop Custom Event values. Response would be similar to:
Custom.ID = 0
Custom.Type = 1332
Custom.Flag = 0
Custom.Value1 = 0
Custom.Value2 = 0
Custom.Value3 = 0
Custom.Text = '1410,1411,1412,1413,1414,1415,1416'
Button set feedback command - Set the feedback type of the button.
ONLY works on General-type buttons.
• Syntax :
"'^BFB-<addr range>,<feedback type>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
feedback type : None, Channel, Invert, On (Always on), Momentary.
• Example :
SEND_COMMAND Panel,"'^BFB-500,Momentary'"
Sets the Feedback type of the button to 'Momentary'.
Button set input mask command - Set the input mask for the specified address.
• Syntax :
"'^BIM-<addr range>,<input mask>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
input mask: Refer to
Appendix C: Text Formatting on page 189 for character types.
• Example :
SEND_COMMAND Panel,"'^BIM-500,AAAAAAAAAA'"
Sets the input mask to ten ’A’ characters, that are required, to either a letter or digit (entry is required).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 112
Programming - Send Commands
Button Commands (Cont.)
^BIT
^BMC
Button Input Type Command - Modifies the keyboard type of the text input button(s) with given address(es). If this is sent to a button that is not a Text Input button, it has no effect.
• Syntax:
"'^BIT-<address range>,<Input Type>,<return port>'"
• Variables :
Address Range : range of addresses that this command applies to
Input Type : Input Type to Change to, as specified here: http://developer.android.com/reference/android/text/InputType.html
1: Text
2: Number (standard keypad)
3: Telephone
4: Date/Time
Return port: The port number to return the response on if different than the port to which the command is sent.
Button copy command - Copy attributes of the source button to all the destination buttons. Note that the source is a single button state. Each state must be copied as a separate command. The <codes> section represents what attributes will be copied. All codes are 2 char pairs that can be separated by comma, space, percent or just ran together.
• Syntax :
"'^BMC-<addr range>,<button states range>,<source port>,<source address>, <sourcestate>,<codes>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
source port : port number of button to copy from.
source address: address number of button to copy from.
source state : state number of button to copy from.
codes :
BM - Picture/Bitmap
BR - Border
CB - Border Color
CF - Fill Color
CT - Text Color
EC - Text effect color
EF - Text effect
FT - Font
JB - Bitmap alignment
JT - Text alignment
OP - Opacity
SO - Button Sound
TX - Text
WW - Word wrap on/off
• Examples :
SEND_COMMAND Panel,"'^BMC-425,1,1,500,1,BR'" or
SEND_COMMAND Panel,"'^BMC-425,1,1,500,1,%BR'"
Copies the OFF state border of button with a variable text address of 500 onto the OFF state border of button with a variable text address of 425.
SEND_COMMAND Panel,"'^BMC-150,1,1,315,1,%BR%FT%TX%BM%CF%CT'"
Copies the OFF state border, font, Text, bitmap, fill color and text color of the button with a variable text address of 315 onto the OFF state border, font, Text, bitmap, fill color and text color of the button with a variable text address of 150.
Note: Use this command if you are using the panel’s default color palette. For custom color palettes, use ^BMF instead.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 113
Programming - Send Commands
Button Commands (Cont.)
^BMF Button Modify Command - Set any/all button parameters by sending embedded codes and data.
• Syntax:
"'^BMF-<addr range>,<button states range>,<data>'"
Note: Many subcommands do not use button state information. Refer to the subcommand for details.
• Variables: address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range: 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
• data :
'%B<border style>'
'%CB<on border color>'
'%CF<on fill color>'
'%CT<on text color>'
'%EC<text effect color>'
'%EF<text effect name>'
'%EN<1 or 0>'
Set the border style name. (No support for states.)
Note: This parameter should be always used in its own BMF command, and should not be combined with other BMF subcommands.
Set Border Color.
Set Fill Color.
Set Text Color.
Set the text effect color.
Set the text effect.
Note: This parameter should be always used in its own BMF command, and should not be combined with other BMF subcommands.
Enable/disable a button.
Set the font filename and optional font size for the primary font and/or the alternate font.
'%F'<primary_font_filename:
primary_font_size>,
<alternate_font_filename:
alternate_font_size'
'%GC<bargraph slider color>'
'%GD<bargraph ramp down>'
'%GG<bargraph drag increment>'
'%GH<bargraph hi>'
'%GI<bargraph invert>'
'%GL<bargraph low>'
'%GN<bargraph slider name>'
'%GR<repeat interval'
'%GU<bargraph ramp up>'
'%GV<bargraph value>'
'%J’,<set text alignment 0-10>'
'%JB<alignment of bitmap 0-10>'
'%JT<alignment of text 0-9>'
'%MI<mask image>'
'%MK<input mask>'
'%ML<max length>'
'%MI<mask image>'
'%OP<0-255>'
'%OP#<00-FF>'
'%OT<feedback type>'
'%P<bitmap,bitmap_index, justification>'
Set the bargraph slider color
Set the bargraph ramp down time in 1/10 second.
Set the bargraph drag increment. Refer to the ^GDI command (page 125) for more
information.
Set the bargraph upper limit.
Set the bargraph invert/non-invert.
Set the bargraph lower limit.
Set the bargraph slider name/Joystick cursor name.
Note: This parameter should be always used in its own BMF command, and should not be combined with other BMF subcommands.
Set bargraph repeat interval.
Set the bargraph ramp up time in intervals of 1/10 second.
Set the bargraph value.
As shown in the Justification Values table (page 166), BUT the 0 (zero) is absolute and
followed by ’,<left>,<top>’
As shown in the Justification Values table (page 166) BUT the 0 (zero) is absolute and
followed by ’,<left>,<top>’
As shown in the Justification Values table (page 166) BUT the 0 (zero) is absolute and
followed by ’,<left>,<top>’
Set the mask image. Refer to the ^BMI command for more information.
Note: This parameter should be always used in its own BMF command, and should not be combined with other BMF subcommands.
Set the input mask of a text area. See the text input mask area for more information.
Note: This parameter should be always used in its own BMF command, and should not be combined with other BMF subcommands.
Set the maximum length of a text area.
Set the mask image. Refer to the ^BMI command for more information.
Note: This parameter should be always used in its own BMF command, and should not be combined with other BMF subcommands.
Set the button opacity to either Invisible (value=0) or Opaque (value=255).
Set the button opacity to either Invisible (value=00) or Opaque (value=FF).
Set the Feedback (Output) Type to one of the following: None , Channel , Invert , ON (Always
ON), Momentary , or Blink .
Note: This parameter should be always used in its own BMF command, and should not be combined with other BMF subcommands.
Set the picture/bitmap filename (empty is clear).
Note: This parameter should be always used in its own BMF command, and should not be combined with other BMF subcommands.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 114
Programming - Send Commands
Button Commands (Cont.)
^BMF
(Cont.)
^BMI
^BML
Data (Cont.):
'%R<l,t,r,b'
'%OP<0-255>'
'%SC<1 or 0>'
'%SF<1 or 0>'
'%SM'
'%SP<spacing>'
'%SO<sound>'
’%SW<1 or 0>'
'%T<text >'
'%UN<Unicode text>'
Sets button location and also resizes the button. For more information, please refer to the
Set the button opacity to either Invisible (value=0) or Opaque (value=255).
Set the bitmap scale to fit.
Set the focus for text area button. (No support for states.)
Submit a text for text area button. (No support for states.)
Set subpage viewer subpage spacing. (No support for states.)
Set the button sound.
Note: This parameter should be always used in its own BMF command, and should not be combined with other BMF subcommands.
Show/hide a button. (No support for states.)
Set the text using ASCII characters (empty is clear).
Note: This parameter should be always used in its own BMF command, and should not be combined with other BMF subcommands.
Set the Unicode text. See ^UNI on page 136 for the text format.
Set the Unicode text. See ^UTF on page 137 for the text format.
'%UT<UTF-8 text>'
'%WW<1 or 0>' Word wrap ON/OFF.
For some of these commands and values, refer to the RGB Values for all 88 Basic Colors table.
• Example:
SEND_COMMAND Panel,"'^BMF-500,1,%B10%CFRed%CB Blue %CTBlack%Ptest.png'"
Sets the button OFF state as well as the Border, Fill Color, Border Color, Text Color, and Bitmap.
Note: Use this command if you are using custom color palette for your panel. If you intend to use the default color palette, use
Note: To accept unspecified parameters, use either ,, or ,-1. If left or top is unspecified, then the current values for the button will be used. If right or bottom is unspecified, the current width and height is used to maintain the button size. This effectively
creates a button "move" command (also works with ^BSP - see page 122.
Set state mask image command - Assign a Chameleon mask image to those buttons with a defined address and state range.
• Syntax:
"'^BMI-<addr range>,<button states range>,<name of mask image>'"
• Variables: address range: Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range: 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). name of mask image: The filename of the mask image in the TPD5 file to use.
Example:
SEND_COMMAND Panel,"'^BMI-500.504&510.515,1,mask.png'"
Sets the OFF state mask image for the buttons with address ranges of 500-504 & 510-515 to mask.png.
Set text input max length command - Set the maximum length of the text area button. If this value is set to zero (0), the text area has no max length. This is only for a Text area input button and not for a Text area input masking button.
• Syntax
"'^BML-<addr range>,<max length>'"
• Variables : address range: Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
max length: The maximum length in characters of a text input area. (0=no max length)
• Example :
SEND_COMMAND Panel,"'^BML-500,20'"
Sets the maximum length of the text area input button to 20 characters.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 115
Programming - Send Commands
Button Commands (Cont.)
^BMP
?BMP
Set State Bitmap Command - Assign a picture to those buttons with a defined address range.
• Syntax :
"'^BMP-<addr range>,<button states range>,<name of bitmap/picture>,[bitmap index],
[optional justification]'"
• Variables : variable text address range: 1 - 4000.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and 2 = On state).
name of bitmap/picture : ASCII characters.
Optional bitmap index: 0 - 5, the state bitmap index to assign the bitmap. If not present, will place the referenced bitmap in index 1. The indexes are defined as:
0 - Chameleon Image (if present)
1 - Bitmap 1
2 - Bitmap 2
3 - Bitmap 3
4 - Bitmap 4
5 - Bitmap 5
Optional justification : 0-10 where:
0 - Absolute position: If absolute justification is set, the next two parameters are the X and Y offset of the bitmap for the referenced index.
1 - top left
2 - top center
3 - top right
4 - middle left
5 - middle center
6 - middle right
7 - bottom left
8 - bottom center
9 - bottom right
10 - scale to fit
11 - scale-maintain-aspect-ratio
If no justification is specified, the current justification is used.
• Example :
SEND_COMMAND Panel,"'^BMP-500.504&510.515,1,bitmap.png'"
Sets the OFF state picture for the buttons with variable text ranges of 500-504 & 510-515.
Query State Bitmap Command - Get the current bitmap name.
• Syntax :
"'?BMP-<addr range>,<button states range>,[index]'"
• Variables : variable text address range: 1 - 4000.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and 2 = On state).
Optional index : 0 - 5, the state bitmap index to assign the bitmap. If not present, will place the referenced bitmap in index 1.
The indexes are defined as:
0 - Chameleon Image (if present)
1 - Bitmap 1
2 - Bitmap 2
3 - Bitmap 3
4 - Bitmap 4
5 - Bitmap 5
The response returned is a custom event with the following properties:
Custom Event Property Value
Port port command was received on
ID address code of button
Type 1002
Flag 0
Value 1 state number
Value 2 length of text
Value 3 bitmap index
Text bitmap name
• Example :
SEND_COMMAND Panel,"'?BMP-529,1'"
Gets the button "OFF state" bitmap information (index 1 since index is unspecified). Example response:
Custom Event Property Value
Port port command was received on
ID 529
Type 1002
Flag 0
Value 1 1
Value 2 9
Value 3 1
Text Buggs.png
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 116
Programming - Send Commands
Button Commands (Cont.)
^BMX Set State Bitmap Extended Command - Assign a set of pictures with justifications to those buttons with a defined address range.
• Syntax :
"'^BMX-<addr range>,<button states range>,<name of bitmap/picture/resource,index,justification>;
<name of bitmap/picture/resource,index,justification>;
<name of bitmap/picture/resource,index, justification>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). name of bitmap: The filename of the bitmap in the TPD5 file to use.
Optional bitmap index : 0 - 5, the state bitmap index to assign the bitmap. If not present, will place the referenced bitmap in index 1. The indexes are defined as:
0 - Chameleon Image (if present)
1 - Bitmap 1
2 - Bitmap 2
3 - Bitmap 3
4 - Bitmap 4
5 - Bitmap 5
Optional justification = 0-11 where:
0 - Absolute position. If absolute justification is set, the next two parameters are the X and Y offset of the bitmap for the referenced index.
1 - top left
2 - top center
3 - top right
4 - middle left
5 - middle center
6 - middle right
7 - bottom left
8 - bottom center
9 - bottom right
10 - scale to fit
11 - scale-maintain-aspect-ratio
If no justification is specified, the current justification is retained.
• Example :
SEND_COMMAND Panel,"'^BMX-500.504&510.515,1,bitmap.png,1,5;bitmap2.png,2,0,100,50;bitmap3.png,3,1'"
Sets the OFF state pictures for the buttons with address ranges of 500-504 & 510-515 as follows: bitmap.png is assigned to index 1 and is middle center justified. bitmap2.png is assigned to index 2 and is absolute justified with an X offset of
100 and a Y offset of 50. bitmap3.png is assigned to index 3 and is top left justified.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 117
Programming - Send Commands
Button Commands (Cont.)
?BMX
Query State Bitmap Extended Command - Get the current bitmap name and justification for one or all indexes.
• Syntax :
"'?BMX-<addr range>,<button states range>,[index]'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). bitmap index : 0 - 5, the state bitmap index to assign the bitmap. If not present, will place the referenced bitmap in index 1.The indexes are defined as:
0 - Chameleon Image (if present)
1 - Bitmap 1
2 - Bitmap 2
3 - Bitmap 3
4 - Bitmap 4
5 - Bitmap 5
The response returned is a series of custom events (one for each valid index) with the following syntax:
Custom Event Property Value
Port Button Address Code
ID address code of button
Type 1018
Flag 0
Value 1 Button state number
Value 2 Length of Custom.Text
Value 3 Index of bitmap (0-5)
Text String that describes the bitmap name/justification.
The text looks like: " bitmapname,justification "
If absolute justification is set, then the X and Y offset are
appended to the description. See page 166 for justification mapping.
• Example :
SEND_COMMAND Panel,"'?BMX-529,1'"
Gets the button 'OFF state' bitmap information (all index with a bitmap since index is unspecified).
Example response:
Custom Event 1:
Custom.ID = 529
Custom.Type = 1018
Custom.Flag = 0
Custom.Value1 = 1
Custom.Value2 = 34
Custom.Value3 = 1
Custom.Text = button-background.png,scale-to-fit
Custom Event 2:
Custom.ID = 529
Custom.Type = 1018
Custom.Flag = 0
Custom.Value1 = 1
Custom.Value2 = 26
Custom.Value3 = 2
Custom.Text = arrow.png absolute,200,100
Custom Event 3:
Custom.ID = 529
Custom.Type = 1018
Custom.Flag = 0
Custom.Value1 = 1
Custom.Value2 = 22
Custom.Value3 = 3
Custom.Text = img_icon,middle-center
For this case, 3 bitmaps are defined and 3 custom event s are sent as a response.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 118
Programming - Send Commands
Button Commands (Cont.)
^BOP
?BOP
^BOS
Button Opacity Command - Set the button opacity in the selected state(s)
• Syntax :
"'^BOP-<addr range>,<button state range>,<opacity>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). opacity : An integer value from 0-255 where 0 is fully transparent and 255 is fully opaque, or #XX where the value after the # is a HEX number between 0 and FF.
• Examples :
SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,200'"
Sets the OFF state opacity for the buttons with address ranges of 500-504 & 510-515 to 200.
SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,#C8'"
Sets the OFF state opacity for the buttons with address ranges of 500-504 & 510-515 to 200 (0xC8).
Get button opacity command - Get the overall button opacity.
• Syntax :
"'?BOP-<addr range>,<button states range>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
The response returned is a series of custom events (one for each valid index) with the following syntax:
Custom Event Property Value
Port port command was received on
ID address code of button
Type 1015
Flag 0
Value 1 state number
Value 2 opacity
Value 3 0
Text
• Examples :
SEND COMMAND Panel,"'?BOP-529,1'"
Gets the button 'OFF state' opacity information. The result sent to the Master would be:
Custom Event Property Value
Port port command was received on
ID 529
Type 1015
Flag 0
Value 1 1
Value 2 200
Value 3 0
Text
Button State Video Fill Command - Sets the button state to display either a Video or Non-Video window.
• Syntax :
"'^BOS-<addr range>,<button states range>,<video state>'"
• Variables : address range: Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). video state : Video Off = 0, URL Video On = 1, MPL Video On = 101.
Example :
SEND_COMMAND Panel,"'^BOS-500,1,1'"
Sets the button to display video.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 119
Programming - Send Commands
Button Commands (Cont.)
?BOS
^BRD
Query Button State Video Fill Command - get the current button state video fill.
• Syntax :
"'?BOS-<addr range>,<button states range>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
The response returned is a custom event with the following syntax:
Custom Event Property Value
Port port command was received on
ID address of the button
Type 1017
Flag 0
Value 1 state number
Value 2 video state
video state values:
0 = no video fill
100 = video fill
101 = MPL video fill
Value 3 0
Text video URL (or empty if no video)
• Example :
SEND_COMMAND Panel,"'?BOS-560,1'"
Gets the button "OFF state" video fill. Example response:
Custom Event Property Value
Port port command was received on
ID 560
Type 1017
Flag 0
Value 1 1
Value 2 1
Value 3 0
Text 1
Button state border command - Set the border of a button state/states.
• Syntax :
"'^BRD-<addr range>,<button states range>,<border name>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). border name : Refer to the Border Styles.
Example :
SEND_COMMAND Panel,"'^BRD-500.504&510.515,1&2,Double Line'"
Sets the border by name (Double Line) to those buttons with the variable text range of 500-504 & 510-515.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 120
Programming - Send Commands
Button Commands (Cont.)
?BRD
^BSF
^BSM
^BSO
Get border name command - Get the current border name.
• Syntax :
"'?BRD-<addr range>,<button states range>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
The response returned is a custom event with the following syntax:
Custom Event Property Value
Port port command was received on
ID address of the button
Type 1014
Flag 0
Value 1 state number
Value 2 text length
Value 3 0
Text border name
• Example :
SEND COMMAND Panel,"'?BRD-529,1'"
Gets the button 'OFF state' border information. The result sent to the Master would be:
Custom Event Property Value
Port port command was received on
ID 529
Type 1014
Flag 0
Value 1 1
Value 2 22
Value 3 11
Text Double Line
Button Focus Command - Set the focus to the text area.
Note: Select one button at a time (single variable text address). Do not assign a variable text address range to set focus to multiple buttons. Only one variable text address can be in focus at a time.
• Syntax :
"'^BSF-<addr range>,<selection value>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
selection value: Unselect = 0 and select = 1.
• Example :
SEND_COMMAND Panel,"'^BSF-500,1'"
Sets the focus to the text area of the button.
Button Submit Text Command - This command causes the text areas to send their text as strings to the NetLinx Master.
• Syntax :
"'^BSM-<addr range>'"
• Variable : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
• Example :
SEND_COMMAND Panel,"'^BSM-500'"
Returns a String of format
"'<button name>-<text>'"
. The string is returned on the port a ^BIT command was received on, or if that has not occurred, is sent on the address port.
Button state sound - Set the sound played when a button is pressed. If the sound name is blank, the sound is then cleared. If the sound name is not matched, the button sound is not changed.
• Syntax :
"'^BSO-<addr range>,<button states range>,<sound name>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range: 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). sound name : Sound file name. If blank or file not found the sound is cleared.
• Example :
SEND_COMMAND Panel,"'^BSO-500,1&2,music.wav'"
Assigns the sound ' music.wav
' to the button Off/On states.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 121
Programming - Send Commands
Button Commands (Cont.)
^BSP Set Button Size and Position Command - Set the button size and its position on the page.
• Syntax :
"'^BSP-<addr range>,<left>,<top>,<right>,<bottom>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
left : position of left edge of the button on the panel top : position of the top edge of the button on the panel right : position of right edge of the button on the panel bottom : position of the bottom edge of the button on the panel
• Example :
SEND_COMMAND Panel,"'^BSP-530,20,100,50,130'"
Makes the button with variable text address 530 appear at (20,100) and be 30px by 30px
As of firmware version 1.6.3, this command has been modified to support default parameters. To specify a default parameter you can either use -1 or leave it empty. This simplifies operations such as button moves where you don't want to calculate a right and bottom.
The meaning of a given defaulted parameter is as follows: left : use the current left position top : use the current top position right : calculate a new right position which is the left position plus the width bottom : calculate a new bottom position which is the top position plus the height
Note: To accept unspecified parameters, use either ,, or ,-1. If left or top is unspecified, then the current values for the button will be used. If right or bottom is unspecified, the current width and height is used to maintain the button size. This effectively
creates a button "move" command (also works with %R in ^BMF - see page 114).
• Example ( An easy button move):
SEND_COMMAND Panel,"'^BSP-530,20,100'"
^BWW Button State Word Wrap Enable/Disable - Set the button word wrap feature to those buttons with a defined address range. By default, word-wrap is Off.
• Syntax :
"'^BWW-<addr range>,<button states range>,<word wrap>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). word wrap : 0=Off and 1=On. Default is Off.
• Example :
SEND_COMMAND Panel,"'^BWW-500,1,1'"
Sets the word wrap on for the button's Off state.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 122
Programming - Send Commands
Button Commands (Cont.)
?BWW
^CPF
^DPF
Get Button State Word Wrap - Get the current word wrap flag status.
• Syntax :
"'?BWW-<addr range>,<button states range>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
Response is a custom event with the following properties:
Custom Event Property Value
Port port command was received on
ID address of the button
Type 1010
Flag 0
Value 1 state number
Value 2 0 = no word wrap, 1 = word wrap
Value 3 0
Text
• Example :
SEND COMMAND Panel,"'?BWW-529,1'"
Gets the button 'OFF state' word wrap information. The result sent to the Master would be:
Custom Event Property Value
Port port command was received on
ID 529
Type 1010
Flag 0
Value 1 1
Value 2 1
Value 3 0
Text
Clear Page Flip Command - Clear all page flips from a button. This only clears PageFlip actions from the Button Release event action.
• Syntax :
"'^CPF-<address range>'"
• Variable : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
• Example :
SEND_COMMAND Panel,"'^CPF-500'"
Clear all page flip actions from button address 500 RELEASE event action list.
Delete Page Flips Command - Delete page flips from a button release event if it already exists.
• Syntax :
"'^DFP-<addr range>,<actions>,<page name>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
actions:
Stan[dardPage] - Flip to standard page
Prev[iousPage] - Flip to previous page
Show[Popup] - Show Popup page
Hide[Popup] - Hide Popup page
Togg[lePopup] - Toggle popup state
ClearG[roup] - Clear popup page group from all pages
ClearP[age] - Clear all popup pages from a page with the specified page name
ClearA[ll] - Clear all popup pages from all pages page name : name of page or popup to affect.
• Example :
SEND COMMAND Panel,"'^DPF-409,Prev'"
Deletes the assignment of a button from flipping to a previous page.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 123
Programming - Send Commands
Button Commands (Cont.)
^ENA
^FON
Button Enable Command - Enable or disable buttons with a set variable text range.
• Syntax :
"'^ENA-<addr range>,<command value>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
command value: 0 = disable, 1 = enable
• Example :
SEND_COMMAND Panel,"'^ENA-500.504&510.515,0'"
Disables buttons with variable text range 500-504 & 510-515.
Button state set font command - Set a font to a specific font filename and size for those buttons with a defined address range.
• Syntax :
"'^FON-<addr range>,<button states range>,<font filename>[:font size],[alternate font filename]
[:alternate font size]'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). font filename: The filename of the font to display in the state. This is used as the primary font file for all button states font size (optional) : The size of the font to use.
alternate font filename: The filename of the alternate font to display in the state. This is used as the alternate font file for a
Listview button font size (optional) : The size of the alternate font to use in a Listview button.
• Examples :
SEND_COMMAND Panel,"'^FON-500.504&510.515,1&2,arialb.ttf:48'"
Sets the font file to arial bold (arialb.ttf) for the On and Off states of buttons with the address range of 500-504 & 510-
515. Set the font size to 48.
SEND_COMMAND Panel,"'^FON-505,1&2,arialb.ttf:48,arial.ttf:24'"
Sets the primary font file to arial bold (arialb.ttf) for the selected (2) and unselected (1) states of Listview buttons with the address range of 505. Set the primary font size to 48. Sets the alternate font file to arial (arial.ttf) and the alternate font size to 24.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 124
Programming - Send Commands
Button Commands (Cont.)
?FON
^GDI
^GIV
Get button state font command - Get the current font filename and size.
• Syntax :
"'?FON-<addr range>,<button states range>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
Response is a custom event with the following properties:
Custom Event Property Value
Port port command was received on
ID address of the button
Type 1007
Flag 0
Value 1 state number
Value 2 font index
Value 3 font size
Text font filename
If the button is a Listview, an additional custom event with the following properties are sent as well.
Custom Event Property Value
Port port command was received on
ID address of the button
Type 1019
Flag 0
Value 1 state number
Value 2 0
Value 3 alternate font size
Text alternate font filename
• Example :
SEND COMMAND Panel,"'?FON-529,1'"
Gets the button 'OFF state' font information. The result sent to the Master would be:
Custom Event Property Value
Port port command was received on
ID 529
Type 1007
Flag 0
Value 1 1
Value 2 1
Value 3 48
Text arialb.ttf
Bargraph drag increment command - Change the bargraph drag increment.
• Syntax :
"'^GDI-<addr range>,<bargraph drag increment>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
bargraph drag increment : The amount to change the level on a drag. The default drag increment is 256.
• Example :
SEND_COMMAND Panel,"'^GDI-7,128'"
Sets the bargraph with address code 7 to a drag increment of 128.
Bargraph invert command - Invert the bargraph to move in the opposite direction.
• Syntax :
"'^GIV-<addr range>,<invert=1, non-inverted=0>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
invert flag : For a bargraph 1 = Invert, 0 = Non Invert
• Example :
SEND_COMMAND Panel,"'^GIV-500,1'"
Invert the bargraph.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 125
Programming - Send Commands
Button Commands (Cont.)
^GLH
^GLL
^GRD
^GRU
^GSC
Set Bargraph High Range Command - Sets the bargraph max range to <bargraph hi>. This does NOT affect the LEVEL value (if any) associated with this bargraph.
• Syntax :
"'^GLH-<addr range>,<bargraph hi>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
bargraph hi: The new high value. It must be larger than the current low value.
• Example :
SEND_COMMAND Panel,"'^GLH-100,128'"
Set the max bargraph value to 128.
Set Bargraph Low Range Command - Sets the bargraph min range to <bargraph low>. This does NOT affect the LEVEL value (if any) associated with this bargraph.
• Syntax :
"'^GLL-<addr range>,<bargraph low>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
bargraph low : The new low value. It must be smaller than the current high value.
• Example :
SEND_COMMAND Panel,"'^GLL-100,64'"
Set the min bargraph value to 64.
Bargraph set ramp down time command - Change the bargraph ramp-down time in 1/10th of a second increments.
• Syntax :
"'^GRD-<addr range>,<bargraph ramp down time>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
bargraph ramp down time: Time to ramp down the entire range in 1/10th of a second intervals.
• Example :
SEND_COMMAND Panel,"'^GRD-500,200'"
Changes the bargraph ramp down time to 20 seconds.
Bargraph set ran up time command - Change the bargraph ramp-up time in 1/10th of a second increments.
• Syntax :
"'^GRU-<addr range>,<bargraph ramp up time>'"
• Variables : address range: Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
bargraph ramp up time : Time to ramp down the entire range in 1/10th of a second intervals.
• Example :
SEND_COMMAND Panel,"'^GRU-500,100'"
Changes the bargraph ramp up time to 10 seconds.
Bargraph set slider color command - Change the bargraph slider color. A user can also assign the color by name or R,G,B value
(RRGGBB or RRGGBBAA).
• Syntax :
"'^GSC-<addr range>,<color value>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
color value:
See the color table on page 165 for more information.
Note: Colors can be set by Color Numbers, Color name, RGB alpha colors (RRGGBBAA) or RGB colors values (RRGGBB). RGBA and RGB color are given in HEX ASCII prepended by a '#'
• Example :
SEND_COMMAND Panel,"'^GSC-500,12'"
Changes the bargraph slider color to Very Light Yellow.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 126
Programming - Send Commands
Button Commands (Cont.)
^GSD
^GSN
^JSB
Bargraph slider display type command - Sets the display type for a slider. In G5, the default bargraph display type is to allow the center of the slider to move to the end of the bargraph and will be clipped visually. In G4 (legacy), the bargraph display type is to allow only the end of the slider to move to the end of the bargraph and the slider is not clipped visually. This command allows the bargraph slider display type to be changed from the G5 (default) type to the G4 type.
• Syntax :
"'^GSD-<addr range>,<display type (g4 or g5)>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
display type: Set the slider display type. A value of g4 will set the display to the G4 type, anything else will set to the G5
(default) type.
• Examples :
SEND_COMMAND Panel,"'^GSD-10,g4'"
Set the display type of the bargraph with address code 10 to the g4 (legacy) type.
SEND_COMMAND Panel,"'^GSD-10,g5'"
Set the display type of the bargraph with address code 10 to the g5 (default) type.
Bargraph set slider name command - Change the bargraph slider name. Slider names can be found in the TPDesign5 slider name drop-down list.
• Syntax :
"'^GSN-<addr range>,<bargraph slider name>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
bargraph slider name : Name of valid sliders. At this point, the valid names are none, Circle -L, Circle -M, Circle -S, Precision,
Rectangle -L, Rectangle -M, and Rectangle -S.
• Example :
SEND_COMMAND Panel,"'^GSN-500,Rectangle -S'"
Changes the bargraph slider name to ’Rectangle -S’.
Set button state bitmap alignment command - Set bitmap/picture alignment using a numeric keypad layout for those buttons with a defined address range. The alignment of 0 is followed by ',<left>,<top>'. The left and top coordinates are relative to the upper left corner of the button.
• Syntax :
"'^JSB-<addr range>,<button states range>,<new alignment>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). new alignment:
Value of 0- 11 (see Justification Values on page 166).
• Example :
SEND_COMMAND Panel,"'^JSB-500.504&510.515,1&2,1'"
Sets the off/on state bitmap alignment to upper left corner for those buttons with address ranges of 500-504 & 510-515.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 127
Programming - Send Commands
Button Commands (Cont.)
?JSB
^JST
Get button state bitmap alignment value - Get the current bitmap alignment.
• Syntax :
"'?JSB-<addr range>,<button states range>'"
• Variables address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). index : The bitmap index to get the value of.
Response is a custom event with the following properties:
Custom Event Property Value
Port port command was received on
ID address of the button
Type 1005
Flag 0
Value 1 state number
Value 2 alignment value 0-10
Value 3 bitmap index
Text alignment description
The alignments description will be one of the following: absolute , top-left, top-center , top-right, middle-left , middle-center , middle-right , bottom-left , bottom-center, bottom-right , scale-to-fit, scale-maintain-aspect-ratio .
If the alignment is absolute , the X and Y offsets will be specified in the text as well: absolute , xoffset , yoffset
• Example :
SEND COMMAND Panel,"'?JSB-529,1,2'"
Gets the button 'OFF state' bitmap justification information for bitmap at index 2. The result sent to the Master would be:
Custom Event Property Value
Port port command was received on
ID address of the button
Type 1005
Flag 0
Value 1 state number
Value 2 5
Value 3 2
Text middle-center
Set button state text alignment command - Set text alignment for those buttons with a defined address range. The alignment of
0 is followed by ',<left>,<top>'. The left and top coordinates are relative to the upper left corner of the button.
• Syntax :
"'^JST-<addr range>,<button states range>,<new alignment>'"
• Variables : address range: Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). new alignment:
Value of 0- 11 (see Justification Values on page 166).
• Example :
SEND_COMMAND Panel,"'^JST-500.504&510.515,1&2,5'"
Sets the off/on state text alignment to middle-center for those buttons with address ranges of 500-504 & 510-515.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 128
Programming - Send Commands
Button Commands (Cont.)
?JST
^SAD
Get the button state text alignment value.
• Syntax :
"'?JST-<addr range>,<button states range>'"
• Variables address range: Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
Response is a custom event with the following properties:
Custom Event Property Value
Port port command was received on
ID address of the button
Type 1004
Flag 0
Value 1 state number
Value 2 alignment value 0-10
Value 3 0
Text alignment description
The alignments description will be one of the following: absolute , top-left , top center , top right , middle left , middle center , middle right , bottom left , bottom center , bottom right , scale to fit .
If the alignment is absolute , the X and Y offsets will be specified in the description as well: absolute,xoffset,yoffset
• Example :
SEND COMMAND Panel,"'?JST-529,1,2'"
Gets the button 'OFF state' text justification information. The result sent to the Master would be:
Custom Event Property Value
Port port command was received on
ID address of the button
Type 1004
Flag 0
Value 1 state number
Value 2 0
Value 3 0
Text absolute,10,10
Subpage add command - Adds a subpage to a viewer button without changing the anchor subpage.
If the named subpage is not present in the set it will be added in the specified position. If no position parameter is supplied the subpage is added to the end of the set. The anchor subpage will not be changed.
If the named subpage is already present, it will be hidden from the set and re-added in the specified position. The anchor subpage will not be changed, unless the named subpage is currently the anchor. In that case, the next appropriate subpage will become the anchor and the named subpage will be added at the appropriate position.
If no subpages are in the set, this command is effectively a Subpage Show command (^SSH).
• Syntax :
"'^SAD-<addr range>,<name>,<optional position>,<optional time>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
name : Specifies the name of the subpage to be shown or added.
position : Specifies where to add the named subpage in the set with 0 representing the beginning of the set. If this value is left out (or set to 65535) then the new subpage is placed at the end of the list.
time : Can range from 0 to 30 and represents tenths of a second. This is the amount of time used to move the subpages around when subpages are added or removed from a button.
• Example :
SEND_COMMAND Panel,"'^SAD-400,media1'"
Add the media1 subpage at the end of the set.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 129
Programming - Send Commands
Button Commands (Cont.)
^SCE Subpage custom event command - Configure subpage custom events. This command can be used to enable or disable the transmission of custom events to the master whenever certain operations occur. For example, the system programmer may want to be notified whenever a subpage enters the anchor position. The notification mechanism is a custom event. The ^SCE command takes the form of a addr range specifying one or more subpage viewer buttons followed by a comma separated list of custom event numbers. If the number is 0 or blank for a given event type then no custom event will be transmitted when that event occurs. If a number is specified, then it is used as the EVENTID value for the custom event. The range of 32001 to 65535 has been reserved in the panel for user custom event numbers. A different value could be used but might collide with other AMX event numbers. Event configuration is not permanent and all event numbers revert to the default of 0 when the panel restarts.
• Syntax :
"'^SCE-<addr range>,<optional anchor event num>,<optional onscreen event num>,
<optional offscreen event num>,<optional reorder event num>'"
• Variables : address range: Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
anchor event number : 0 for no event or a value from 32001 to 65535.
onscreen event number : 0 for no event or a value from 32001 to 65535.
offscreen event number : 0 for no event or a value from 32001 to 65535.
reorder event number : 0 for no event or a value from 32001 to 65535.
The events are:
• anchor - a new subpage has docked in the anchor position.
• onscreen - a docking operation has been completed and the subpages in the list are now onscreen. This list will include the anchor along with any subpages that may be partially onscreen.
• offscreen - a docking operation has been completed and the subpages in the list are now offscreen.
• reorder - the user has reordered the subpages in the set and the list contains all subpages in the new order without regard to onscreen or offscreen state.
In response to any or all of the above events, the panel will create a string which is a list of subpage names separated by a pipe (|) character. The string for the anchor event is a single subpage name. If this string is too long to be transmitted in a single custom event, then multiple custom events will be created and transmitted. If defined, the events are sent in this order when a docking operation completes on a given viewer button: anchor, onscreen, offscreen. If reorder is defined and occurs, it is sent first: reorder, anchor, onscreen, offscreen.
The format of the custom event transmitted to the master is as follows:
Custom Event Property Value
Port port command was received on
ID address of the button generating the event
Type the non-zero event number in the ^SCE command
Flag 0
Value 1 which one of possible multiple events this is (1 based)
Value 2 total number of events needed to send the entire string
Value 3 the total size of the original string in bytes
Text pipe character separated list of subpage names
• Example :
SEND_COMMAND Panel, "'^SCE-200,32001,0,0,0'"
If the subpage named TV_Favorite_SyFy enters the anchor position on a subpage viewer button with an address of 200, the following event would be transmitted to the master when the user had sent this command to the panel:
Custom Event Property Value
Port port command was received on
ID 200
Type 32001
Flag 0
Value 1 1
Value 2 1
Value 3 16
Text TV_Favorite_SyFy
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 130
Programming - Send Commands
Button Commands (Cont.)
?SCE
^SDL
Query Subpage Custom Event Numbers Command - Query the assigned subpage custom event numbers for a subpage viewer button. A series of custom events for the subpage viewer button may be sent as a response.
• Syntax :
"'?SCE-<addr range>'"
• Variable : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
The format of the custom event transmitted to the master is as follows:
Custom Event Property Value
Port port command was received on
ID address of the button generating the event
Type the non-zero event number in the ^SCE command
Flag 0
Value 1 which one of possible multiple events this is (1 based)
Value 2 total number of events needed to send the entire string
Value 3 the total size of the original string in bytes
Text pipe character separated list of subpage names
• Example (Assuming the previous command, '^SCE-200,32001,0,0,0', has been sent…):
SEND_COMMAND Panel, "'?SCE-200'"
If the subpage named TV_Favorite_SyFy enters is in the anchor position on a subpage viewer button with an address of 200, the following event would be transmitted to the master when the user had sent this command to the panel:
Custom Event Property Value
Port port command was received on
ID 200
Type 32001
Flag 0
Value 1 1
Value 2 1
Value 3 16
Text TV_Favorite_SyFy
Streaming digital video loop count - This command allows a button state that has video fill to a streaming URL to set a number of times to play a video. This applies to local file video streams primarily.
• Syntax :
"'^SDL-<Address range>,<State range>,<loop count>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). loop count : number of times to loop a completed video. 0 = loop indefinitely (default), >0 = number of times to loop.
• Example :
SEND_COMMAND Panel,"'^SDL-10,1&2,1'"
Set the loop count to 1 for address 10 on and off states.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 131
Programming - Send Commands
Button Commands (Cont.)
^SDM Button State Streaming Digital Media Command - Starts or stops a streaming session. Stream starts if a valid URL is specified and stops if server URL string is empty or invalid. To use this command, the current page should have one visible streaming button.
• Syntax :
"'^SDM-<address range>,<button states range>,<URL>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
URL : <protocol://><host name or host ip><:video port><:optional audio port>
URL for connected MXA-MPL = udp://169.254.11.12:5700
Protocol could have the following values: udp = MPEG2 transport stream over UDP http = Motion JPEG (JFIF format over MIME Multipart) [Modero X Series Panels Only] rtpmpeg2 = MPEG2 elementary stream over RTP/RTCP [Modero X Series Panels do not support] rtpmpeg4 = MPEG4 elementary stream over RTP/RTCP [Modero X Series Panels do not support]
If the optional audio port is not specified, video port + 2 is used for audio.
Playing a video file stored on a USB drive attached to the panel
Enter the path of the video file on the attached USB drive with "file:///udisk/ " as the prefix:
"'^SDM-<Address range>,<State range>,file:///udisk/path_to_video_file_on_usb_drive'"
Note: There are three slashes after "file:", not two as in a standard URL. If there aren't three slashes, the video file won't be found to be played.
For example, for a video file named " test-video.mp4
" in a directory named " videos " on the USB drive, enter:
" file:///udisk/videos/test-video.mp4
"
Playing a video file stored on the panel
Enter the filename of the video file with " amxdir:/// " as the prefix.
"'^SDM-<Address range>,<State range>,amxdir:///video_file'"
Note: There are three slashes after "amxdir:", not two as in a standard URL. If there aren't three slashes, the video file won't be found.
For example, for a video file named " test-video.mp4
", enter:
" amxdir:///test-video.mp4
"
To change the video using the ^SDM command to a different video (that has been transfered to the panel), use the same URL scheme as the prefix (amxdir:///).
Note that any files that are transfered to the amxdir:/// directory are not cleared by a panel file transfer or via "Remove User
Pages". The only way to clear the file is to do a Factory Data Reset, or to upload an empty file with the same filename. To get around this, you can specify the file to be in "amxdir:///AMXPanel/images/filename" instead.
To do this using NetLinx Studio File Transfer, set the "Master Directory" to \AMXPanel\images\ in the device mapping. This will put the file in the panel file images directory. A TP5 file transfer will not remove the file, but a "Remove User Pages" will.
The Streaming Source value in the TP5 file will have to correspond to the same path.
for playing a video file in the G5 panel’s internal storage.
• Examples :
SEND_COMMAND Panel,"'^SDM-400,1,file:///udisk/Video-Clip.mp4'"
Set the OFF state to play the video file Video-Clip.mp4 located on an attached USB disk.
SEND_COMMAND 10001:2:0,"'^SDM-10,2,udp://234.4.0.4:5500'"
Sets ON state to play video on multicast address.
SEND_COMMAND 10001:2:0,"'^SDM-10,1,cam://local'"
Sets OFF state to play camera.
SEND_COMMAND 10001:2:0,"'^SDM-10,1,stop'"
Stop playing the current video.
SEND_COMMAND 10001:2:0,"'^SDM-10,1,'"
Stop playing the current video.
SEND_COMMAND 10001:1:0,"'^SDM-10,1,udp://169.254.11.12:5700'"
Start playing the current video.
Note: When using the variable "udp," this must be in lower case.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 132
Programming - Send Commands
Button Commands (Cont.)
^SDR
^SHA
^SHD
^SHO
^SPD
Enabling subpage dynamic reordering command - This command can be used to enable or disable dynamic reordering for a given viewer button or set of viewer buttons. It can also be used to set the amount of time to wait before initiating the single finger reorder time.
• Syntax :
"'^SDR-<addr range>,<enable state>,<optional hold time>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
enable state : This value can be either "on" or "ON" or "1" to enable dynamic reordering for the specified viewer button(s).
Any other value will disable dynamic reordering for the specified viewer button(s).
hold time : This value is in tenths of a second. The value will be rounded up to the next highest quarter of a second. This is the amount of time that the user must press and hold a subpage with a single finger to trigger a dynamic reordering operation.
Subpage Hide All Command - Hide all subpages in a subpage viewer button.
• Syntax :
"'^SHA-<addr range>'"
• Variables : address range: Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
• Example :
SEND_COMMAND Panel,"'^SHA-200'"
Remove all subpages from subpage viewer button with address 200.
Subpage Hide Command - This command will hide the named subpage and relocate the surrounding subpages as necessary to close the gap. If the subpage to be hidden is currently offscreen then it is removed without any other motion on the subpage viewer button.
• Syntax :
"'^SHD-<addr range>,<name>,<optional time>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
name : name of subpage to hide. If name is __all, then all subpages are hidden.
time : Can range from 0 to 30 and represents tenths of a second. This is the amount of time used to move the subpages around when subpages are hidden from a button.
• Example :
SEND_COMMAND Panel,"'^SHD-200,menu1,10'"
Remove the menu1 subpage from subpage viewer button with address 200 over one second.
Button Show/Hide Command. Show or hide a button.
• Syntax :
"'^SHO-<addr range>,<command value>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
command value: 0 = hide, 1 = show
• Example :
SEND_COMMAND Panel,"'^SHO-500.504&510.515,0'"
Hides buttons with variable text address range 500-504 & 510-515.
Subpage Padding Command - Set the padding between subpages on a subpage viewer button.
• Syntax :
"'^SPD-<addr range>,<padding>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
padding : percentage from 0 to 100 of the first subpage in a set to set as a padding between subpages. For a horizontal subpage viewer button it is a percentage of the width and for a vertical subpage viewer button it is a percentage of the height.
• Example :
SEND_COMMAND Panel, "'^SPD-400,10'"
Set the padding between subpages in the set to 10% of the dimension of the first subpage in the set.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 133
Programming - Send Commands
Button Commands (Cont.)
^SSH
^STG
^TEC
Subpage Show Command - This command will perform one of three different operations based on the following conditions: a) If the named subpage is hidden in the set associated with the viewer button it will be shown in the anchor position.
b) If the named subpage is not present in the set it will be added to the set and shown in the anchor position.
c) If the named subpage is already present in the set and is not hidden, then the viewer button will move it to the anchor position. The anchor position is the location on the subpage viewer button specified by its weighting. This will either be left, center or right for horizontal subpage viewer buttons or top, center or bottom for vertical subpage viewer buttons.
Surrounding subpages are relocated on the viewer button as needed to accommodate the described operations.
• Syntax :
"'^SSH-<addr range>,<name>,<optional position>,<optional time>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
name : Specifies the name of the subpage to be shown or added.
position : Specifies where to add (or show) the named subpage in the set with 0 representing the beginning of the set. If this value is left out (or set to 65535) then the weighting value for the viewer button is used to place the new subpage, i.e. left/ top, center or right/bottom. When using the weighting locations, set insertion positions can vary based on the current onscreen locations of existing subpages.
time : Can range from 0 to 30 and represents tenths of a second. This is the amount of time used to move the subpages around when subpages are added or removed from a button.
• Example :
SEND_COMMAND Panel,"'^SSH-400,media1,0,10'"
Add or show the media1 subpage in the anchor position over one second.
Subpage Toggle Command - If the named subpage is hidden, then this command activates a subpage show command. If the named subpage is present, then a subpage hide command is activated.
• Syntax :
"'^STG-<addr range>,<name>,[optional position],[optional time]'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
name : Specifies the name of the subpage to be shown or added.
position : Specifies where to show the named subpage in the set with 0 representing the beginning of the set. If this value is left out (or set to 65535) then the weighting value for the viewer button is used to place the new subpage, i.e. left/top, center or right/bottom. When using the weighting locations, set insertion positions can vary based on the current onscreen locations of existing subpages. If the subpage is being hidden this parameter is ignored.
time : Can range from 0 to 30 and represents tenths of a second. This is the amount of time used to move the subpages around when subpages are added or removed from a button.
• Example :
SEND_COMMAND Panel,"'^STG-400,media1,0,10'"
Show or hide the media1 subpage over one second.
Set text effect color command - Set the text effect color for the specified addresses/states to the specified color. The Text Effect is specified by name and can be found in TPD5. You can also assign the color by name or RGB value (RRGGBB or RRGGBBAA).
• Syntax :
"'^TEC-<addr range>,<button states range>,<color value>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). color value : See color table for more information.
Note: Colors can be set by Color Numbers, Color name, RGB alpha colors (RRGGBBAA) or RGB colors values (RRGGBB). RGBA and
RGB color are given in HEX ASCII prepended by a '#'
• Example :
SEND_COMMAND Panel,"'^TEC-500.504&510.515,1&2,12'"
Sets the text effect color to Very Light Yellow on buttons with variable text 500-504 and 510-515.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 134
Programming - Send Commands
Button Commands (Cont.)
?TEC
^TEF
?TEF
Get text effect color command - Get the current text effect color.
• Syntax :
"'?TEC-<addr range>,<button states range>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
The format of the custom event transmitted to the master is as follows:
Custom Event Property Value
Port port command was received on
ID address of the button generating the event
Type 1009
Flag 0
Value 1 button state number
Value 2 actual length of string
Value 3 0
Text Hex encoded color value (ex: #000000FF)
• Example :
SEND COMMAND Panel,"'?TEC-529,1'"
Gets the button 'OFF state' text effect color information. The result sent to the Master would be:
Custom Event Property Value
Port port command was received on
ID address of the button generating the event
Type 1009
Flag 0
Value 1 1
Value 2 9
Value 3 0
Text #5088F2AE
Set the current text effect command - Set the current text effect.
• Syntax :
"'^TEF-<addr range>,<button states range>,<text effect name/number>'"
• Variables : address range: Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). text effect name/number
: See the Text Effect Name/Numbers table on page 137 for text effect names and numbers.
• Example :
SEND_COMMAND Panel,"'^TEF-500.504&510.515,1&2,Soft Drop Shadow 3'"
Sets the text effect to Soft Drop Shadow 3 for the button with variable text range 500-504 and 510-515.
Get the current text effect command - Get the current text effect.
• Syntax :
"'?TEF-<addr range>,<button states range>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state).
The format of the custom event transmitted to the master is as follows:
Custom Event Property Value
Port port command was received on
ID address of the button generating the event
Type 1008
Flag 0
Value 1 button state number
Value 2 actual length of string
Value 3 text effect number
Text text effect name
• Example :
SEND COMMAND Panel,"'?TEF-529,1'"
Gets the button 'OFF state' text effect name information. The result sent to the Master would be:
Custom Event Property Value
Port port command was received on
ID 529
Type 1008
Flag 0
Value 1 1
Value 2 18
Value 3 27
Text Hard Drop Shadow 3
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 135
Programming - Send Commands
Button Commands (Cont.)
^TXT
?TXT
^UNI
Set button state text command - Assign a Non-Unicode, non-UTF-8 text string to those buttons with a defined address range.
Note that this command has been replaced by ^UTF, but is being kept for backwards compatibility. It supports ASCII characters, but extended ASCII (i.e. characters from 128-255) are interpreted according to the Latin-1 character set (ISO
8859-1). Unicode (i.e. characters > 255) are not supported.
• Syntax :
"'^TXT-<addr range>,<button states range>,<new text>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). new text: new text as ASCII characters.
• Example :
SEND_COMMAND Panel,"'^TXT-500.504&510.515,1&2,Test Only'"
Sets the On and Off state text for buttons with the variable text ranges of 500-504 & 510-515.
Query button state text command - Get the text of a button state.
• Syntax :
"'?TXT-<addr range>,<button states range>[,<optional index>]'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range: 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). optional index : This is used if a string was too long to get back in one command. The reply will start at this index.
The response returned is a custom event with the following syntax:
Custom Event Property Value
Port port command was received on
ID address of the button generating the event
Type 1001
Flag 0: Legacy Latin-1 (ISO-8859-1) encoded characters
(^ENC must have previously been sent to change default encoding method)
1: Legacy AMX Hex Quad encoded Unicode characters
2: UTF-8 encoded Characters (default encoding; ASCII-compatible)
Value 1 button state number
Value 2 actual length of string
Value 3 optional index
Text text from the button, encoded with the method specified by Flag
• Example :
SEND_COMMAND Panel,"'?TXT-529,1'"
Gets the button 'OFF state' text information. Example Response:
Custom Event Property Value
Port port command was received on
ID 529
Type 1001
Flag 2
Value 1 1
Value 2 14
Value 3 0
Text This is a test
Set button state legacy unicode text command - Set Unicode text in the legacy G4 format. For the ^UNI command, the Unicode text is sent as ASCII-HEX nibbles.
Note: In the legacy format, Unicode text is always represented in a HEX value. TPD generates (through the Text Enter Box dialog)
Unicode HEX values. Refer to the TPDesign Instruction Manual for more information. This command has been replaced by ^UTF, but is being kept for backwards compatibility.
• Syntax :
"'^UNI-<addr range>,<button states range>,<unicode text>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons, 1 = Off state and 2 = On state). unicode text: Unicode HEX value.
• Examples :
SEND_COMMAND Panel,"'^UNI-500,1,0041'"
Sets the button's unicode character to 'A'.
SEND_COMMAND TP,"'^UNI-1,0,0041'"
Send the variable text 'A' in unicode to all states of the variable text button 1, (for which the character code is 0041 Hex).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 136
Programming - Send Commands
Button Commands (Cont.)
^UTF Set button state text using UTF-8 text command - Set State Text Command using UTF-8 (replaces the ^TXT and ^UNI commands). Assign a text string encoded with UTF-8 (which is ASCII-compatible) to those buttons with a defined address range.
Note: This command replaces the legacy ^TXT command and the legacy ^UNI command, but text must be encoded with UTF-8.
While UTF-8 is ASCII compatible, extended ASCII characters in the range 128-255 will be encoded differently based on UTF-8.
This command also supports Unicode characters using UTF-8 (which is the encoding method used in >80% of web servers), making the old AMX Hex quad Unicode encoding obsolete (though the ^UNI command is still supported for backwards compatibility).
• Syntax :
"'^UTF-<vt addr range>,<button states range>,<new text>'"
• Variables : variable text address range : 1 - 4000.
Button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and 2 = On state).
unicode text: Unicode UTF-8 text.
• Example :
SEND_COMMAND Panel,"’^UTF-500.504&510.515,1&2, ASCII ExtendedASCII Çüéâäàåç Unicode 動き始めました ’"
Sets the On and Off state text for buttons with the variable text ranges of 500-504 & 510-515.
Text Effect Name/Numbers
Text Effect Name/Numbers
Number Name
24
25
26
27
28
29
20
21
22
23
16
17
18
19
12
13
14
15
8
9
10
11
6
7
4
5
2
3
0
1
None
Outline -S
Outline -M
Outline -L
Outline -X
Glow -S
Glow -M
Glow -L
Glow -X
Soft Drop Shadow 1
Soft Drop Shadow 2
Soft Drop Shadow 3
Soft Drop Shadow 4
Soft Drop Shadow 5
Soft Drop Shadow 6
Soft Drop Shadow 7
Soft Drop Shadow 8
Med Drop Shadow 1
Med Drop Shadow 2
Med Drop Shadow 3
Med Drop Shadow 4
Med Drop Shadow 5
Med Drop Shadow 6
Med Drop Shadow 7
Med Drop Shadow 8
Hard Drop Shadow 1
Hard Drop Shadow 2
Hard Drop Shadow 3
Hard Drop Shadow 4
Hard Drop Shadow 5
54
55
56
50
51
52
53
46
47
48
49
42
43
44
45
38
39
40
41
34
35
36
37
Number Name
30
31
32
33
Hard Drop Shadow 6
Hard Drop Shadow 7
Hard Drop Shadow 8
Soft Drop Shadow 1 with Outline
Soft Drop Shadow 2 with Outline
Soft Drop Shadow 3 with Outline
Soft Drop Shadow 4 with Outline
Soft Drop Shadow 5 with Outline
Soft Drop Shadow 6 with Outline
Soft Drop Shadow 7 with Outline
Soft Drop Shadow 8 with Outline
Medium Drop Shadow 1 with Outline
Medium Drop Shadow 2 with Outline
Medium Drop Shadow 3 with Outline
Medium Drop Shadow 4 with Outline
Medium Drop Shadow 5 with Outline
Medium Drop Shadow 6 with Outline
Medium Drop Shadow 7 with Outline
Medium Drop Shadow 8 with Outline
Hard Drop Shadow 1 with Outline
Hard Drop Shadow 2 with Outline
Hard Drop Shadow 3 with Outline
Hard Drop Shadow 4 with Outline
Hard Drop Shadow 5 with Outline
Hard Drop Shadow 6 with Outline
Hard Drop Shadow 7 with Outline
Hard Drop Shadow 8 with Outline
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 137
Programming - Send Commands
Dynamic Image Commands
Dynamic Image Commands
^BBR
^RAF
Button State Bitmap Resource Command - Assign a resource to those buttons with a defined address range.
• Syntax :
"'^BBR-<vt addr range>,<button states range>,<resource name>,[optional bitmap index],
[optional justification]'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
button states range : 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and
2 = On state).
resource name : name of resource
Optional bitmap index: 1 - 5, the state bitmap index to assign the resource. If not present, will place the referenced resource in index 1. The indexes are defined as:
0 - Chameleon Image (if present)
1 - Bitmap 1
2 - Bitmap 2
3 - Bitmap 3
4 - Bitmap 4
5 - Bitmap 5
Optional justification : 0-11 (see
Justification Values on page 166). If absolute justification (0) is set, the next
two parameters are the X and Y offset of the bitmap for the referenced index. If no justification is specified, the current justification is used.
• Example :
SEND_COMMAND Panel,"'^BBR-500.504&510.515,1,image_xray'"
Sets the OFF state picture for the buttons with variable text ranges of 500-504 & 510-515 to the resource named image_xray .
Resource Add Command - Add new resources. Adds any and all resource parameters by sending embedded codes and data. Since the embedded codes are preceded by a '%' character, any '%' character contained in the URL must be escaped with a second '%' character (see example). The file name field (indicated by a %F embedded code) may contain special escape sequences as shown in the ^RAF, ^RMF - Embedded Codes table on page 141.
Note: For server authentication to occur, the %U (username) and %S (password) Embedded Codes must be included, and they must match the credentials required by the server.
• Syntax :
"'^RAF-<resource name>,<data>'"
• Variables : resource name : name of the resource to add.
data : Refers to the embedded codes, see the ^RAF, ^RMF - Embedded Codes on page 141.
Note: The %P, %U, %S, %H, %A, and %F values can be entered In a single string .
Example :
SEND_COMMAND Panel,"'^RAF-New Image, %P0%HAMX.COM%ALab/Test%%5Ffile%Ftest.jpg'"
Adds a new resource.
The resource name is 'New Image'
%P (protocol) is 0 for an HTTP connection
%H (host name) is AMX.COM
%A (file path) is Lab/Test_file
%F (file name) is test.jpg.
Note: the %%5F in the file path is actually encoded as %5F.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 138
Programming - Send Commands
Dynamic Image Commands (Cont.)
^RFR Refresh Resource Command - Force a refresh of the given resource. The command will refresh when the resource is visible onscreen. If it is not onscreen, it will be deferred until it is visible to do the refresh. An optional notification option can be set to receive a custom event from the panel when the resource refresh is complete.
Optional width and height parameters can be specified to refresh the image at a specific resolution. If width and height parameters are not specified, the resource will be refreshed at the resolution(s) of any active buttons to which it is assigned. If there are no active buttons currently assigned that resource, it will be refreshed at its native resolution adjusted by any project scale factor.
• Syntax :
"'^RFR-<resource name>,[notification option],[width],[height]'"
• Variables :
Resource name : name of the resource to refresh
Notification option : An optional notification option at the end of the command with the following possible values:
On - notifications are sent whenever the named dynamic image resource is loaded/refreshed.
Off - notifications are not sent (default).
Once - notifications are sent one time whenever the named dynamic image resource is loaded/refreshed.
Notifications are not sent on subsequent loads/refreshes.
width : Specifies the width at which the resource should be refreshed (the image will be scaled as needed).
height : Specifies the height at which the resource should be refreshed (the image will be scaled as needed).
• Examples :
SEND_COMMAND Panel,"'^RFR-Sports_Image,on'"
Force a refresh on ' Sport_Image ' when the resource is visible onscreen and enable completion notifications.
^RFRP
SEND_COMMAND Panel,"'^RFR-Sports_Image,off'"
Force a refresh on ' Sport_Image ' when the resource is visible onscreen and disable completion notifications.
SEND_COMMAND Panel,"'^RFR-Sports_Image,once'"
Force a refresh on ' Sport_Image ' when the resource is visible onscreen and enable a onetime completion notification.
SEND_COMMAND Panel,"'^RFR-Sports_Image,once,800,600'"
Force a refresh on ' Sport_Image ' at the resolution 800x600 when the resource is visible onscreen and enable a onetime completion notification.
Resource Refresh Prefetch Command - Force a refresh of the given resource. The command will "prefetch" the resource even if it is not currently visible.
• Syntax :
"'^RFRP-<resource name>,[notification option],[width],[height]'"
• Variables :
Resource name : name of the resource to refresh
Notification option : An optional notification option at the end of the command with the following possible values:
On - notifications are sent whenever the named dynamic image resource is loaded/refreshed.
Off - notifications are not sent (default).
Once - notifications are sent one time whenever the named dynamic image resource is loaded/refreshed.
Notifications are not sent on subsequent loads/refreshes.
width : Specifies the width at which the resource should be refreshed (the image will be scaled as needed).
height : Specifies the height at which the resource should be refreshed (the image will be scaled as needed).
Examples :
SEND_COMMAND Panel,"'^RFRP-Sports_Image,on'"
Force a refresh on ' Sport_Image ' immediately and enable completion notifications.
SEND_COMMAND Panel,"'^RFRP-Sports_Image,off'"
Force a refresh on ' Sport_Image ' immediately and disable completion notifications.
SEND_COMMAND Panel,"'^RFRP-Sports_Image,once'"
Force a refresh on ' Sport_Image' immediately and enable a one-time completion notification.
SEND_COMMAND Panel,"'^RFRP-Sports_Image,once,800,600'"
Force a refresh on ' Sport_Image ' immediately at the resolution 800x600 and enable a onetime completion notification.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 139
Programming - Send Commands
Dynamic Image Commands (Cont.)
^RMF
^RSR
^RAF, ^RMF -
Embedded Codes
^RAF, ^RMF - Escape
Sequences
Resource Modify Command - Modifies any and all resource parameters by sending embedded codes and data.
Since the embedded codes are preceded by a '%' character, any '%' character contained in the URL must be escaped with a second '%' character (see example). The file name field (indicated by a %F embedded code) may contain special escape sequences as shown in the ^RAF, ^RMF - Embedded Codes table on page 141.
Note: For server authentication to occur, the %U (username) and %S (password) Embedded Codes must be included, and they must match the credentials required by the server.
• Syntax :
"'^RMF-<resource name>,<data>'"
• Variables : resource name : name of the resource to modify data : Refers to the embedded codes, see the ^RAF, ^RMF - Embedded Codes on page 141.
Note: The %P, %U, %S, %H, %A, and %F values can be entered In a single string.
• Example :
SEND_COMMAND Panel,"'^RMF-Sports_Image, %ALab%%5FTest/Images%Ftest.jpg'"
Changes the resource ' Sports_Image ' file name to ' test.jpg
' and the path to 'Lab_Test/Images'.
Note: the %%5F in the file path is actually encoded as %5F.
Resource Rate Command - Change the refresh rate for a given resource.
• Syntax :
"'^RSR-<resource name>,<refresh rate>'"
• Variables : resource name : name of the resource to set the refresh rate.
refresh rate : Measured in seconds.
• Example :
SEND_COMMAND Panel,"'^RSR-Sports_Image,5'"
Sets the refresh rate to 5 seconds for the given resource (' Sports_Image ').
The ^RAF and ^RMF commands add and modify any and all resource parameters by sending embedded codes and data:
"'^RAF-<resource name>,<data>'"
"'^RMF-<resource name>,<data>'"
The <data> variable uses the embedded codes described in the ^RAF and ^RMF Embedded Codes table on page 141.
The ^RAF and ^RMF commands support the replacement of any special escape sequences in the filename
(specified by the %F embedded code) with the corresponding data obtained from the system as outlined in
the^RAF and ^RMF Escape Sequences table on page 142
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 140
Programming - Send Commands
^RAF and ^RMF Embedded Codes / Escape Sequences
NOTE: The %P, %U, %S, %H, %A, and %F values can be entered In a single string.
^RAF and ^RMF Embedded Codes
Parameter Embedded Code protocol
%P<0|1|2> user
%U <user>
Code Description
Set protocol: Either HTTP (0) or FTP (1), or HTTPS(2)
Notes:
• FTP is not supported at this time.
• HTTPS (%P2) is supported in G5 panel firmware v1.4.9 and higher.
Set Username for authentication.
password host path
%S <password>
%H <host>
%A <path> file refresh preserve dynamo notification
%C<on,off,once>
URL
%F <file>
%R <refresh 1-65535>
%V <0-1>
%D
%L <URL>
Set Password for authentication.
Set Host Name (fully qualified DNS or IP address).
Set directory path. The path must be a valid HTTP URL minus the protocol, host, and filename.
The only exception to this is the inclusion of special escape sequences and in the case of the
FTP protocol, regular expressions.
The file or program that will return the resource. The file must be a valid HTTP URL minus the protocol, host, and path. The only exception to this is the inclusion of special escape sequences and in the case of the FTP protocol, regular expressions.
The number of seconds between refreshes in which the resource is downloaded again.
Refreshing a resource causes the button displaying that resource to refresh also. The default value is 0, which means to only download the resource once for each time it comes into view (or if preserve is set, only once period).
Note: For Motion JPEGs, the Refresh interval should always be 0.
Set the value of the preserve flag. A value of 0 (the default) means the resource should be reloaded each time it comes into view. A value of 1 means the resource should be preserved in cache after the first time it is loaded, and not reloaded each time it comes into view. This value is ignored if the Refresh interval is greater than 0.
Enable/disable Fast Dynamo. Panel will attempt to accelerate this resource in hardware.
Note: Fast Dynamo is not yet supported.
Indicates whether a notification is required when a Dynamic Image is loaded/refreshed. The string following the %C can be:
1. on notifications are sent whenever the named dynamic image resource is loaded/ refreshed.
2. off notifications are not sent (default).
3. once notifications are sent one time whenever the named dynamic image resource is loaded/refreshed.
Notifications are not sent on subsequent loads/refreshes. If the %C code is not sent as part of a ^RAF command, the notifications are set to off. If the %C code is not sent as part of a ^RMF command, the notifications are not changed from the current setting.
Set the complete URL as a single value. URL is in the format set in RFC 2396.
Code Block http://username:password@host:port/directory/file?query#fragment
Note: The %P, %U, %S, %H, %A, and %F values can be entered In a single string.
Note: If the URL is the first part of the resource data, then the %L is assumed and need not be included. See example below.
Example:
The following send commands are equivalent. All examples set the resource Image1 to a URL of http://server/folder1/image.jpg with a username of username, password of password, notifications on, and refresh time of 30 seconds:
SEND_COMMAND Panel,'^RMF-Image1,%Lhttp://username:password@server/folder1/ image.jpg%Con%R30'
SEND_COMMAND Panel,'^RMF-Image1,%P0%Uusername%Spassword%Hserver%Afolder1
%Fimage.jpg%Con%R30'
SEND_COMMAND Panel,'^RMF-Image1,http://username:password@server/folder1/ image.jpg%Con%R30'
SEND_COMMAND Panel,'^RMF-Image1,http://server/folder1/image.jpg%Con%R30%
Uusername%Spassword'
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 141
Programming - Send Commands
^RAF and ^RMF Escape Sequences
Sequence Panel Information
$DV
Device Number
$SY
$IP
$HN
$MC
System Number
IP Address
Host Name
Mac Address
$PX
$PY
$ST
X resolution of current panel mode/file
Y resolution of current panel mode/file
Current state
Address code
$AC
Intercom Commands
Intercom Commands
^ICE
^ICM-LISTEN
^ICM-MUTEMIC
^ICM-SPEAKERLEVEL
^ICM-TALK
Sequence Panel Information
$AP
Address port
$CC
$CP
$LC
$LP
Channel code
Channel port
Level code
Level port
$BX
$BY
$BN
X Resolution of Current button
Y Resolution of Current button
Name of Button
Intercom call end command - This terminates an intercom call/connection.
• Syntax :
"'^ICE'"
• Example :
SEND_COMMAND TP1,"'^ICE'"
SEND_COMMAND TP2,"'^ICE'"
Terminates an intercom call between two panels.
Intercom call set to LISTEN mode command - Set the intercom call to LISTEN mode.
• Syntax :
"'^ICM-LISTEN'"
• Example :
SEND_COMMAND TP1,"'^ICM-TALK'"
Set the intercom mode for this panel to LISTEN mode.
Intercom call mute mic command - Sets the state of the microphone on a panel to muted (1) or unmuted (0).
At the start of each call, the microphone starts out unmuted.
• Syntax :
SEND_COMMAND <DEV>, "^ICM-MICLEVEL,<value>"
• Example :
SEND_COMMAND TP1, "^ICM-MUTEMIC,1"
Mute the microphone.
Intercom call speaker call volume command - Sets the speaker level during an intercom call (0 to 100).
• Syntax :
SEND_COMMAND <DEV>, "^ICM-SPEAKERLEVEL,<value>"
• Variables :
Level : Speaker call level 0-100.
• Example :
SEND_COMMAND TP1, "^ICM-SPEAKERLEVEL,55"
Set the speaker call volume to 55.
Intercom call set to TALK mode command - Set the intercom call to TALK mode.
• Syntax :
"'^ICM-TALK'"
• Example :
SEND_COMMAND TP1,"'^ICM-TALK'"
Set the intercom mode for this panel to TALK mode.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 142
Programming - Send Commands
Intercom Commands (Cont.)
^ICS
^MODEL?
Intercom call start command - Starts a call to the specified IP address and ports, where initial mode is either 1
(talk) or 0 (listen) or 2 (both). If no mode is specified 0 (listen) is assumed.
Note: No data packets will actually flow until the intercom modify command is sent to the panel.
• Syntax :
"'^ICS-<IP>,<TX UDP port>,<RX UDP port>,<initial mode>'"
• Variables :
IP : IP Address of panel to connect with on an Intercom call.
TX UDP port : UDP port to transmit to.
RX UDP port : UDP port to receive from.
initial mode: 0 (listen) or 1 (talk) or 2 (handsfree). 0 is the default.
• Example of setting up a handsfree unicast call between two panels:
SEND_COMMAND TP1, "^ICS-192.168.0.3,9000,9002,2"
SEND_COMMAND TP2, "^ICS-192.168.0.4,9002,9000,2"
• Example of setting up a multicast call where the first panel is paging two other panels:
SEND_COMMAND TP1, "^ICS-239.252.1.1,9002,9000,1"
SEND_COMMAND TP2, "^ICS-239.252.1.1,9002,9000,0"
SEND_COMMAND TP3, "^ICS-239.252.1.1,9002,9000,0"
• Example of setting up a baby monitor call where the first panel is listening to the microphone audio coming from the second panel:
SEND_COMMAND TP1, "^ICS-192.168.0.3,9000,9002,0"
SEND_COMMAND TP2, "^ICS-192.168.0.4,9002,9000,1"
Note: When integrating the intercom functionality between AMX devices and non-AMX devices, please note that the RX UDP port should be used by the non-AMX device to receive audio.
Get model name for intercom command - Gets model name. If the panel supports intercom hardware it will respond with its model name as shown in the response below. Older hardware or newer hardware that has intercom support disabled with not respond to this command.
• Syntax :
"'^MODEL?'"
• Variables : None.
• Example :
SEND_COMMAND TP1,"'^MODEL?'"
Panel response string if intercom enabled:
^MODEL-MXT-1001i
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 143
Programming - Send Commands
SIP Commands
Panel to Master
The following table lists and describes SIP commands that are generated from the touch panel.
SIP Commands - Panel to Master
^PHN-AUTOANSWER
^PHN-CALL
^PHN-INCOMING
SIP auto answer status - Provides the state of the auto-answer feature.
• Syntax :
"'^PHN-AUTOANSWER,<state>'"
• Variable : state : 0 or 1 (off or on)
• Example :
^PHN-AUTOANSWER,1
The panel sent a command status to the master indicating the auto-answer is on.
SIP call progress status - Provides call progress notification for a call.
• Syntax :
"'^PHN-CALL,<status>,<connection id>'"
• Variables status : CONNECTED, DISCONNECTED, ERROR, HOLD, REJECTED, RINGING, or TRYING.
connection id : The identifying number of the connection.
• Example :
^PHN-CALL,CONNECTED,1
The panel sent a command status to the master indicating call 1 is CONNECTED.
SIP incoming call status - Provides incoming call notification and the connection ID used for all future commands related to this call. The connection id will be 0 or 1.
• Syntax :
"'^PHN-INCOMING,<caller number>,<caller name>,<connection id>, <timestamp>'"
• Variables : caller number: The phone number of the incoming call caller name : The name associated with the caller number connection id : The identifying number of the connection timestamp : The current time in MM/DD/YY HH:MM:SS format
• Example :
^PHN-INCOMING,"1235556789",MAIN,1,01/01/2011 11:11:11
The panel sent a command status to the master indicating an incoming call from number 1235556789 named MAIN at Jan 1, 2011 at 11:11:11.
^PHN-LINESTATE
^PHN-MSGWAITING
SIP call linestate status - Indicates the current state of each of the available connections used to manage calls.
• Syntax :
"'^PHN-LINESTATE,<connection id>,<state>,<connection id>,<state>,..., SIP,<extn>'"
• Variables : connection id : The identifying number of the connection.
state : IDLE, HOLD, or CONNECTED extn : The local extension of this panel (see Example)
• Example :
^PHN-LINESTATE,1,IDLE,2,CONNECTED,SIP,1234
The panel sent a command status to the master indicating line 1 is idle and line 2 is connected and this is extension 1234.
SIP call message waiting status - Indicates the number of messages waiting the user’s voice mail box.
• Syntax :
"'^PHN-MSGWAITING,<messages>,<new message count>,<old message count>,
<new urgent message count>,<old urgent message count>'"
Variables : messages : 0 or 1 (1 indicates new messages) new message count : The number of new messages.
old message count : The number of old messages.
new urgent message count : The number of new messages marked urgent.
old urgent message count: The number of old messages marked urgent.
• Example :
^PHN-MSGWAITING,1,1,2,1,0
The panel sent a command status to the master indicating there are calls waiting (1 new, 2 old, 1 new urgent, 0 old urgent).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 144
Programming - Send Commands
SIP Commands - Panel to Master
^PHN-PRIVACY
^PHN-REDIAL
^PHN-TRANSFERRED
SIP call privacy status - Indicates the state of the privacy feature.
• Syntax :
"'^PHN-PRIVACY,<state>'"
• Variables : state : 0 (Disable) or 1 (Enable) new message count : The number of new messages.
old message count: The number of old messages.
new urgent message count: The number of new messages marked urgent.
old urgent message count: The number of old messages marked urgent.
• Example :
^PHN-PRIVACY,0
The panel sent a command status to the master indicating there the call privacy is disabled.
SIP call redial status - Indicates the panel is redialing the number.
• Syntax :
"'^PHN-REDIAL,<number>'"
• Variable : number : The phone number to dial.
• Example :
^PHN-REDIAL,2125551000
The panel sent a command status to the master indicating the number 2125551000 is being redialed.
SIP call transferred status - Indicates a call has been transferred.
• Syntax :
"'^PHN-TRANSFERRED,<connection id>'"
• Variable : connection id: The identifying number of the connection.
• Example :
^PHN-TRANSFERRED,1
The panel sent a command status to the master indicating call 1 was transferred.
Master to Panel
The following table lists and describes SIP commands that are sent to the touch panel to manage calls.
SIP Commands - Master to Panel
^PHN-ANSWER
^PHN-AUTOANSWER
?PHN-AUTOANSWER
SIP call answer command - Answers the call.
• Syntax :
"'^PHN-ANSWER,<connection id>'"
• Variable : connection id : The identifying number of the connection
• Example :
SEND_COMMAND Panel,"'^PHN-ANSWER,1'"
Answer call 1.
SIP set auto-answer state command - Enables (1) or disables (0) the auto-answer feature on the phone.
• Syntax :
"'^PHN-AUTOANSWER,<state>'"
• Variable : state : 0 (Disable) or 1 (Enable)
• Example :
SEND_COMMAND Panel,"'^PHN-AUTOANSWER,1'"
Enable the auto-answer feature.
Get SIP auto-answer state command - Queries the state of the auto-answer feature.
The panel responds with the ^PHN-AUTOANSWER, <state> message.
• Syntax :
"'?PHN-AUTOANSWER'"
• Example :
SEND_COMMAND Panel,"'?PHN-AUTOANSWER'"
Get the auto-answer status.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 145
Programming - Send Commands
SIP Commands - Master to Panel (Cont.)
^PHN-CALL
^PHN-DECLINE
^PHN-DTMF
^PHN-HANGUP
^PHN-HOLD
?PHN-LINESTATE
^PHN-PRIVACY
SIP call command - Calls the provided number.
• Syntax :
"'^PHN-CALL,<number>'"
• Variable : number : The provided phone number
• Example :
SEND_COMMAND Panel,"'^PHN-CALL,2125551000'"
Call the number 2125551000.
Declines the incoming call on <Connection ID> as indicated from the previous message. Decline (send to voice mail if configured) the incoming call on <connection id> as indicated from the previous ^PHN-
INCOMING message. Connection ID should be 0 or 1.
• Syntax :
"'^PHN-DECLINE,<Connection ID>'"
• Variable :
Connection ID : The identifying number of the connection.: The identifying number of the connection.
• Example :
SEND_COMMAND Panel,"'^PHN-DECLINE,0'"
Decline the call with ID of 0.
SIP send DTMF tone command - Sends DTMF codes.
• Syntax :
"'^PHN-DTMF,<DTMF code>,[<Connection ID>]'"
• Variable :
DTMF code : 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, POUND, or ASTERISK.
Connection ID: Optional Connection ID.
If >= 0, the DTMF is generated on the specified connection ID.
If < 0 then DTMF is generated on first line in use.
• Examples :
SEND_COMMAND Panel,"'^PHN-DTMF,5'"
Send the DTMF tone for 5.
SEND_COMMAND Panel,"'^PHN-DTMF,ASTERISK,1'"
Send the DTMF tone for * on connection 1.
SIP hangup call command - Hangs up the call.
• Syntax :
"'^PHN-HANGUP,<connection id>'"
• Variable : connection id : The identifying number of the connection
• Example :
SEND_COMMAND Panel,"'^PHN-HANGUP,1'"
Hangup the call with ID of 1.
SIP put call on hold command - Places the call on hold.
• Syntax :
"'^PHN-HOLD,<connection id>'"
• Variable : connection id : The identifying number of the connection
• Example :
SEND_COMMAND Panel,"'^PHN-HOLD,1'"
Put the call with ID of 1 on hold.
Get SIP linestate command - Queries the state of each of the connections used by the SIP device.The panel responds with the ^PHN-LINESTATE message.
• Syntax :
"'?PHN-LINESTATE'"
• Example :
SEND_COMMAND Panel,"'?PHN-LINESTATE'"
Get the current line states.
SIP set privacy state command - Enables or disables the privacy feature on the phone (do not disturb).
• Syntax :
"'^PHN-PRIVACY,<state>'"
• Variable : state : 0 (Disable) or 1 (Enable)
• Example :
SEND_COMMAND Panel,"'^PHN-PRIVACY,1'"
Enables the privacy feature.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 146
Programming - Send Commands
SIP Commands - Master to Panel (Cont.)
?PHN-PRIVACY
^PHN-REDIAL
^PHN-TRANSFER
^PHN-SETUP-CODEC
^PHN-SETUP-DOMAIN
^PHN-SETUP-
DTMFDURATION
^PHN-SETUP-ENABLE
Get SIP privacy state command - Queries the state of the privacy feature. The panel responds with the
^PHN-PRIVACY, <state> message.
• Syntax :
"'?PHN-PRIVACY'"
• Example :
SEND_COMMAND Panel,"'?PHN-PRIVACY'"
Get the current SIP privacy status.
SIP call redial command - Redials the last number.
• Syntax :
"'^PHN-REDIAL'"
• Example :
SEND_COMMAND Panel,"'^PHN-REDIAL'"
Redial the last number.
SIP call transfer message - Transfers the call to the provided number.
• Syntax :
"'^PHN-TRANSFER,<connection id>,<number>'"
• Variables : connection id : The identifying number of the connection number : The number to which you want to transfer the call.
• Example :
SEND_COMMAND Panel,"'^PHN-TRANSFER,1,2125551000'"
Transfer call with ID 1 to 2125551000.
Set SIP codec command - Set the codec type for the SIP connection.
• Syntax :
"'^PHN-SETUP-CODEC,<codec>'"
• Variables : codec : The codec to use. Valid values are ulaw (default) or alaw .
• Example
SEND_COMMAND Panel,"'^PHN-SETUP-CODEC,ulaw'"
Set the SIP audio codec to ulaw.
Set SIP domain name command - Set the domain name for the SIP server.
• Syntax :
"'^PHN-SETUP-DOMAIN,<domain name>'"
• Variables : domain name : The domain name to use for the sip connection.
• Example
SEND_COMMAND Panel,"'^PHN-SETUP-DOMAIN,sip.domain'"
Set the SIP domain to sip.domain
.
Set the duration of SIP DTMF tones command - Set the duration of DTMF tones generated by the panel for a SIP connection.
• Syntax :
"'^PHN-SETUP-DTMFDURATION,<duration>'"
• Variables : duration : The duration in ms of DTMF tones generated by the panel for a SIP connection. Valid ranged are 100 (default) to 3000.
• Example
SEND_COMMAND Panel,"'^PHN-SETUP-DTMFDURATION,500'"
Set the duration of DTMF tones generated for SIP to 500ms.
Enable SIP setup command - Registers a new user. Once the configuration has been updated, the ENABLE command should be run to re-register the new user.
• Syntax :
"'^PHN-SETUP-ENABLE'"
• Variables : enable: 1 to enable SIP, and 0 to disable.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 147
Programming - Send Commands
SIP Commands - Master to Panel (Cont.)
^PHN-SETUP-PASSWORD
^PHN-SETUP-PORT
^PHN-SETUP-PROXYADDR
^PHN-SETUP-USERNAME
Setup SIP password command - Sets the user password so this extension can connect to the SIP server
(SIP proxy server).
• Syntax :
"'^PHN-SETUP-PASSWORD,<password>'"
• Variable : password : The password for the user name
• Example :
SEND_COMMAND Panel,"'^PHN-SETUP-PASSWORD,6003'"
Setup the password for this extension to 6003.
Setup port for SIP Server connection command - Sets the port number for the SIP server (SIP proxy address).
• Syntax :
"'^PHN-SETUP-PORT,<port>'"
• Variable : port : The port for the proxy server
• Example :
SEND_COMMAND Panel,"'^PHN-SETUP-PORT,5060'"
Set this extension to connect to the SIP server (SIP proxy address) to port 5060.
Setup SIP server address command - Sets the IP address for the SIP server (SIP proxy address).
• Syntax :
"'^PHN-SETUP-PROXYADDR,<IP>'"
• Variable :
IP : The IP address for the proxy server
• Example :
SEND_COMMAND Panel,"'^PHN-SETUP-PROXYADDR,192.168.223.111'"
Set the extension to try the SIP server (SIP proxy address) at the IP of 192.168.223.111.
Setup SIP username command - Sets the user name for authentication with the SIP server (SIP proxy address).
• Syntax :
"'^PHN-SETUP-USERNAME,<username>'"
• Variable : username : The user name (usually the phone extension)
• Example :
SEND_COMMAND Panel,"'^PHN-SETUP-USERNAME,6003'"
Set the extension to authenticate to the SIP server with the username of 6003.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 148
Programming - Send Commands
Listview (Data Access) Commands
The Data Access commands described in the following table represent a set of Button (^) Send Commands that support the use of dynamic data for Listview buttons in NetLinx code. Note that the address range indicated in the syntax examples represents the address of the Listview button, and works the same as it does for all other (^) Button Send Commands.
Many Listview Send Commands take a boolean parameter. Any of the following values can be used:
Will resolve to true Will resolve to false true
TRUE on false
FALSE off
ON
1
OFF
0
(empty)
Terminology
The NetLinx Data Access Send Commands use the following terminology:
Netlinx Data Access Send Commands - Terminology
Name
DataFeed
Description
A DataFeed is a descriptor with a unique name used to publish data records. A DataFeed can be created by a NetLinx program and then published to the NetLinx web server for external consumption by devices like the G5 touch panel for use with Listview buttons. DataFeeds can also be sourced from a server running the AMX XPort software.
DataRecord A DataRecord represents a container of data fields and the index/ordinal position of the row in the recordset. A DataRecord may contain metadata and/or content fields.
DataField A DataField represents the value that stores the actual data elements. All raw data in the NetLinx data access APIs are stored and managed as values and (one or more) attributes.
Listview Commands
^LVC Listview Cache Configure - This command configures the image cache used by the Listview.
• Syntax :
"'^LVC-<configuration_option=configuration_value>'"
• Variables : a comma separated list of one or more configuration parameters followed by an equal sign and the configuration setting.
• Configuration Options : clear : Clear the current memory and disk cache used for Listview image loading.
mem_size : The size of the memory cache, either as a percentage of the available application memory or as total size.
Percentages are specified as floating point. Percentage values are 2% (0.02) to 20% (0.20) and totals are 16 to 256 MB.
The default is 10%.(0.10) disk_size : The size of the disk cache. Valid values are 16 to 500 MB The default is 200.
• Example :
SEND_COMMAND Panel,"'^LVC-clear'"
Clear the Listview cache.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 149
Programming - Send Commands
Listview Commands (Cont.)
^LVD Set Listview Data Source - This command sets the data source to drive the Listview entries. Note that this command only
issued to load the data.
• Syntax :
"'^LVD-<addr range>,<URL to data source or Dynamic Data Resource name>,
<configuration_option=configuration_value>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
Data source URL/Dynamic Data Resource name (required): If the suffix of the URL is .csv or .CSV then the URL will be assumed to point to a csv file. Otherwise the type is assumed to be the XPort amxstandard.xml format. Supported URL schemes are HTTP , HTTPS , and FILE .
Data Source URL Notes:
HTTPS is supported in G5 panel firmware version v1.4.9 and higher.
HTTPS is not supported by TPDesign5 dynamic image resources at this time.
A file on the panel's local filesystem can be specified using the file:/// option. There must be three forward slashes after 'file:' .
An FTP URL scheme is not supported.
Refer to Notes on Using Image URLs With Listview Buttons on page 155 for additional details.
option list : a optional comma separated list of one or more configuration parameters followed by an equal sign and the configuration setting.
• Configuration Options : user - The user name to use for authenticating to the web server when retrieving the feed data source file.
If specified when URL is a Dynamic Data Resource, this value will override the username inside the Dynamic Data
Resource.
Note: For server authentication to occur, the Username (user) and Password (pass) must be included in the ^LVD command, and they must match the credentials required by the server. pass - The password to use for authenticating to the web server when retrieving the feed data source file.
If specified when URL is a Dynamic Data Resource, this value will override the password inside the Dynamic Data Resource.
Note: For server authentication to occur, the Username (user) and Password (pass) must be included in the ^LVD command, and they must match the credentials required by the server. csv - a boolean indicating whether or not to parse the data source as a CSV file.
If not present, defaults to false.
has_headers - a boolean indicating that the first line of the CSV file has column headers which will be used to name the content fields for each data record.
If true it automatically implies that csv is also true.
If this option is not present then the default for a CSV file is false.
In the absence of headers, the content fields will be named using the following convention: column1 , column2 , column3 ...
(CSV files only, since XML always has field names specified within the file).
• Example :
SEND_COMMAND Panel,"'^LVD-42,http://192.168.220.231/public/lv42data.csv, has_headers=1'"
Configures the Listview button to use the CSV file at the URL as its data source. The first line of the CSV file should be parsed as field names and not as Listview entry record data.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 150
Programming - Send Commands
Listview Commands (Cont.)
^LVE
^LVF
^LVL
Set ListView custom event number - This command sets the custom event number reported by Listview refresh operations.
• Syntax :
"'^LVE-<addr range>,<Listview custom event number>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
event number : The custom event number to report Listview events. At this time, only refresh events are reported. A value of 0 turns off custom event reporting, A value > 0 assigns the value to the Listview custom event number for that address. The default value is 1401 (custom events reported).
When enabled, the custom event format reported is:
Custom Event Property Value
Port port command was received on
ID address of the button
Type button event number set by ^LVE
Flag StartRefresh = 1; FinishRefresh = 2; Error = 0xffff ($FFFF);
Value 1 If flag is StartRefresh (1) or FinishRefresh (2):
InitRefresh = 0; (refresh by dynamic resource)
ManualRefresh = 1; (refresh by send command
TimedRefresh = 2; (refresh by timer)
If flag is Error:
Error = -1; (some form of error, see custom.text for description)
InvalidUrl = -2; (URL is null, should never happen)
LoginFailed = -3; (could not authenticate to web server).
Value 2 data load id. Every data load is assigned a unique id that counts up
from 0. This is used to correlate StartRefresh/FinishRefresh/Error events
on particular addresses.
Value 3 When Custom.flag == FinishRefresh, this is the number of records in list
Otherwise is 0.
Text feed URL string, or error message if flag is Error
• Example :
SEND_COMMAND Panel,"'^LVE-42,1401'"
Configures the Listview widget to send Listview custom events on event 1401.
Listview Filter - This command can be used to programmatically change the filter contents of the Listview widget. When the filter contents is changed, the filter will be applied to the current Listview data which can change the number of items displayed based on those that meet the filter sequence. The filter changes immediately, and the filter can be set or cleared with this command.
• Syntax :
"'^LVF-<addr range>,<filter character sequence>'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
filter character sequence : All characters including white space characters will be applied to the filter.
• Example :
SEND_COMMAND Panel,"'^LVF-42,amx'"
Sets the filter sequence to amx . Only items in the data set that contain the sequence amx will be displayed.
SEND_COMMAND Panel,"'^LVF-42,'"
Clears the filter sequence. All items in the data set can be viewed in the Listview.
Listview Layout - This command sets the layout configuration to configure the visual representation of the Listview entries.
• Syntax :
"'^LVL-<vt addr range>,<layout_option=layout_value>'"
• Variables :
Variable text address range = 1 - 4000.
A comma separated list of one or more layout configuration parameters followed by an equal sign and the configuration setting.
• Layout Options : columns - Number of columns parameter. An integer that represents the number of columns to display. The number must be at least 1 and a value that exceeds the minimum cell width will truncate to the maximum.
Note: Valid tags for the columns parameter are columns=, nc=, and numcol=.
comp - Component parameter. An integer that is a value which determines which graphical components are present in the cell. When the component values are bitwise or'd together, it creates the encoding for the cell components that are populated. If a configuration parameter is not in the current command, the last value for the configuration parameter is used.
Note: Valid tags for the comp parameter are c= and comp=.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 151
Programming - Send Commands
Listview Commands (Cont.)
^LVL
(Cont.)
Component Value
1
2
2
3
4
5
6
Description
The image (i) is used in the cell.
The primary text field (t1) is used in the cell.
4 The secondary text field (t2) is used in the cell
Not all variations of component values are valid. To have the secondary text field present, the primary text field must be preset as well.
Component Combinations Description
0 Invalid. No component displayed.
1 The image (i) is the only component displayed.
The primary text field (t1) is the only component displayed.
The image (i) and the primary text field (t1) are displayed.
Secondary text (t2) only. Invalid. Secondary text (t2) cannot be displayed without the primary text (t1).
Secondary text (t2) and image (i). Invalid. Secondary text (t2) cannot be displayed without the primary text (t1).
The primary text (t1) and secondary text (t2) are displayed.
7 The image (i), primary text (t1), and secondary text (t2) are displayed cellheight - An integer or percentage that sets the height of a cell. The value can be an integer >= the minimum cell height
(48), or a percentage of the list height (5% up to 95%). To specify a percentage, append a '%' to the end of the value.
Note: Valid tags for the cellheight param are ch= and cellheight=.
layout - An integer that sets the layout configuration of each cell.
Note: valid tags for the layout parameter are l= and layout=.
Layout Value Description
1
2
3
4
5
Horizontal layout with image on the left and text(s) on the right.
If multiple texts are selected then the texts are stacked vertically
Horizontal layout with image on the right and text(s) on the left.
If multiple texts are selected then the texts are stacked vertically.
Horizontal layout with text1 on the left, image in the center, and text2 on the right.
If multiple texts are selected then the texts are stacked vertically.
Vertical layout with the image on the top and text(s) below the image.
If multiple texts are selected then text1 is below the image and text2 is below text1.
Vertical layout with the image on the bottom and text(s) above the image.
If multiple texts are selected then text1 is on top, text2 is below text1, and the image is below text2.
6 Vertical layout with text1 on top, the image below text1, and text2 below the image. p1 - layout percentage 1. Sets the boundaries between cell components in different layouts. An integer between 10 and 90 that sets the boundary between components as a percentage of the cell dimension. The percentage can be specified as a number between 5-95 with an optional percentage sign '%' at the end.
p2 - layout percentage 2. Sets the boundaries between cell components in different layouts.An integer between 10 and 90 that sets the boundary between components as a percentage of the cell dimension. The percentage can be specified as a number between 5-95 with an optional percentage sign '%' at the end.
filter - Enable or disable the search filter on the Listview. To enable set to 'true', 'on', or '1'. To disable set to 'false', 'off', or
'0'.
Note: Valid tags for the filter parameter are f= and filter=.
filterheight - An integer or percentage that sets the height of the filter in the Listview. The value can be an integer >= the minimum filter height (24), or a percentage of the list height (5% to 25%). To specify a percentage, append a '%' to the end of the value.
Note: Valid tags for the filterheight param is fh= and filterheight=.
alphascroll - Enable or disable the alpha scroll on the Listview. To enable set to 'true', 'on', or '1'. To disable set to 'false',
'off', or '0'.
Note: Valid tags for the alphascroll parameter are as= and alphascroll=.
• Examples :
SEND_COMMAND Panel,"'^LVL-42, layout=1, comp=7, columns=1, cellheight=120, p1=40%, p2=66%'"
Sets the Listview configuration display an image and 2 text fields (comp=7), in a layout 1 configuration (layout=1 horizontal layout of the image on left and text1 and text2 to the right of the image). There is 1 column (columns=1) and the cell is 120 pixels high (h=120). The image width will be 40% of the cell width (p1=40%) with text1 and text2 having a width of 60% of the cell width. The height of text1 will be 66% of the cell height (p2=66%) with text2 height of 34% of the cell height.
SEND_COMMAND Panel,"'^LVL-42,l=4, c=3, ch=150, nc=4, p1=70'"
Sets the Listview configuration display an image and 1 text fields (c=4), in a layout 4 configuration (l=4 vertical layout of the image on top and text1 below the image). There are 4 columns (nc=4) and the cell is 150 pixels high (ch=150). The image height will be 70% of the cell height (p1=70) with text1 having a height of 30% of the cell height.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 152
Programming - Send Commands
Listview Commands (Cont.)
^LVL
(Cont.)
SEND_COMMAND Panel,"'^LVL-42,layout=3, comp=6, ch=100, numcol=1, p1=50'"
Sets the Listview configuration display 2 text fields (comp=6), in a layout 3 configuration (layout=2 horizontal layout of text1 on the left and text2 on the right). There is 1 column (numcol=1) and the cell is 100 pixels high (ch=100). The text1 width will be 50% of the cell width (p1=50) with text2 having a width of 50% of the cell width.
^LVM
^LVN
SEND_COMMAND Panel,"'^LVL-42,filter=1, fh=10%, as=false'"
Sets the Listview search filter enabled (filter=1), the search filter textview height to 10% of the Listview height
(fh=10%), and disables the alphascroller on the Listview.
Listview Map Fields - This command maps the fields from the data source to the display elements of a Listview entry. Each list entry corresponds to a record if the data came from the NetLinx data access API or XPort. If the data source is a csv file, then each list entry corresponds to a row in the file. A list entry can have up to two lines of text and a URL that points to an image.
Each display element for a list entry has to be mapped to a field in the record. If no mapping is specified, then a default mapping is used which is simply to map the fields in order based on the screen layout of the list entry. So, if the list type was an image and two lines of text, the first content field in the record would be interpreted as the URL to the image, the next field would be the first line of text and the next field would be the second line of text. To override this default behavior, the ^LVM command should be used to specify the correct mapping.
• Syntax :
"'^LVM-<addr range>,<display_element=field_expression|<display_element= field_expression>|...'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
display element list : A pipe character "|" separated list of mapping expressions. A pipe is used because typical field expressions may use more common characters such as the comma or semicolon.
Display Elements: t1 - the first text element t2 - the second text element i1 - the first image future display types may support more text and image elements which will follow the same convention: t3... i2...
• Field Expressions :
An expression that can be used to map field values to display elements. Any time a field name is used, it follows the form
${field_name} . Other text characters can be used to construct a more complex string using multiple fields.
• Examples :
SEND_COMMAND Panel,"'^LVM-42,i1=${image}'"
Configures the Listview widget to map an image field to the image display element. In this example, the Listview type is assumed to be a single image only.
SEND_COMMAND Panel,"'^LVM-42,i1=${image}|t1=${lname}, ${fname}|t2=${number}'"
The Listview widget is the type that has an image and two lines of text. The top line will consolidate two different fields in the form of last name, first name. The second line of text will be the phone number.
SEND_COMMAND Panel,"'^LVM-42,t1=${column2}, ${column1}|t2=${column3}|i1=${column4}'"
This is the same example as the one above it but the source of the data was a csv file that didn't have any headers. The csv columns were laid out as first name, last name, number, url to image.
Listview Navigate - This command can be used to move the Listview widget. Navigation commands will be range checked. The command will attempt to position the specified list entry on the top line of the Listview widget. When navigating at the end of the list, however, the widget will position the last item in the list on the bottom line and will not leave blank lines at the bottom.
The only exception to this case will be when the Listview has fewer entries than the number of displayable entries. If the optional select boolean is present, and the navigation command used support the select option, the item at the destination will be selected and a item selected custom event will be initiated.
• Syntax :
"'^LVN-<addr range>,<navigation_command>[,<boolean_select_param>]'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
navigation command .
optional select boolean
Navigation Commands: t or T - move to the top of the list (supports an optional select boolean).
b or B - move to the bottom of the list (supports an optional select boolean).
d or D - page down (DOES NOT support the optional select boolean. A select boolean will be ignored if present).
n - move to a specific list entry number at position n. n is a zero based index. (supports an optional select boolean).
(Note: If n is < 0 and select is true then the current selected item is deselected.) u or U - page up (DOES NOT support the optional select boolean. A select boolean will be ignored if present).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 153
Programming - Send Commands
Listview Commands (Cont.)
^LVN
(Cont.)
^LVR
^LVS
• Examples :
SEND_COMMAND Panel,"'^LVN-42,B'"
Move to the bottom of the list.
SEND_COMMAND Panel,"'^LVN-42,d'"
Move the list down a page.
SEND_COMMAND Panel,"'^LVN-42,3,1'"
Move the list to position 3 in the list and select the item at position 3.
Listview Refresh Data - This command has two different functions. If it is sent without any parameters, it causes the Listview widget to load data from its configured data source. If optional parameters are included with the command, then the automatic data refresh options are configured. The typical behavior for auto refresh is that the last modified time of the data source is tracked. At the refresh interval, the last modified time of the data source is compared against the stored value. If the data is newer, then it is reloaded and the Listview widget is refreshed with the updated data. If the data is unchanged, then it is not reloaded. The default for auto refresh is off.
• Syntax :
"'^LVR-<addr range>[,<refresh_interval>,<force_reload>]'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
refresh_interval - the optional interval (in seconds) at which to check for newer data. 0 (the default) means auto refresh is off. Minimum is 5 seconds. If not specified, the current refresh interval is retained.
force_reload - the optional parameter to force the Listview to ignore and data file timestamps and to force a clear on image caches for refreshed Listview images. Not specified or 0 will not force a reload, 1 will force a reload of data file and images associated with data file.
Note: This can cause the images in a Listview to flicker upon the reload. This is the expected behavior due to the images being reloaded from the server.
• Examples :
SEND_COMMAND Panel,"'^LVR-42'"
Commands the Listview widget to load the data from the data source and populate the Listview display widget.
SEND_COMMAND Panel,"'^LVR-42,15'"
Commands the Listview widget to check for an updated data source every 15 seconds.
SEND_COMMAND Panel,"'^LVR-42,600,1'"
Commands the Listview widget to check for an updated data source every hour, and to force a reload of the data and the images.
Listview Sort Data - This command sets the columns that are used for sorting of lists, as well as the type of sorting that is done.
The multiple columns are allowed in the sort procedure. The order of the columns in the command determine the order of the sorting. The first column is the primary sorting data, the second would be used for sorting with rows of data that are equal in the primary columns, and so on for however many columns are used for sorting. If no columns are listed in the command, then the current sorting columns are used if they have been previously defined. The type of sort is an optional part of the command and follows the sort columns.
Initially, there are four different sort types available.
None ( n ) - No sorting is performed.
Ascending ( a ) - Ascending sort using localized character weighting.
Descending ( d ) - Descending sort using localized character weighting.
Override ( * ) - Override sort syntax portion of command determines sorting.
The override sort syntax allows for complex SQLite ORDER BY syntax for sorting. When override is selected, the sort columns that were set in the command or previously are ignored and the entire sorting statement must be in the override sort syntax.
The words ORDER BY should not be in the syntax. They are inserted by the firmware.
• Syntax :
"'^LVS-<addr range>,<primary sort column name, secondary sort column name,..., final sort column name>[;<sort type>[;<override sort syntax>]]'"
• Variables : address range : Address codes of buttons to affect. A '.' between addresses includes the range, and & between addresses includes each address.
Sort columns - comma separated list of sort columns in the order of sort priority. Sort columns can be specified using the
${column name} syntax that is used in the ^LVM command. Columns can be Content Fields or Metadata Fields in the master
Datafeed XML file generated by the master. Metadata fields are prepended with "meta" in front of the "label" attribute of the field.
Sort Type - A character indicating the sorting algorithm to use.
'a' - ascending
'd' - descending
'*' - override. Sort command syntax must follow in the next part of the command.
'n' - none (default). Any character that is not a,d, or * will set sort to none.
Override sort syntax - A SQLite ORDER BY statement to use as the sort.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 154
Programming - Send Commands
Listview Commands (Cont.)
^LVS
(Cont.)
Examples :
SEND_COMMAND Panel,"'^LVS-42, ${artist name},${title};a '"
Commands the Listview widget to sort the data source by the artist name and then title in an ascending order. Equates to
"artistname, title COLLATE LOCALIZED ASC" override syntax.
SEND_COMMAND Panel,"'^LVS-42, ${artist name},${title};d '"
Commands the Listview widget to sort the data source by the artist name and then title in an descending order. Equates to
"artistname COLLATE LOCALIZED DESC, title COLLATE LOCALIZED DESC" override syntax.
SEND_COMMAND Panel,"'^LVS-42,;n'"
Commands the Listview widget to not sort the current data.
SEND_COMMAND Panel,"'^LVS-150,${user name},${text};*;meta${Record timestamp} ASC'"
Commands the panel to sort by the meta data field Record timestamp in ASCENDING order. The username and test fields are ignored.
SEND_COMMAND Panel,"'^LVS-150,;*;meta${Record timestamp} ASC'"
Commands the panel to sort by the meta data field "Record timestamp" in ASCENDING order. The username and test columns are ignored.
SEND_COMMAND Panel,"'^LVS-150,;*;LENGTH(${description}),${description} ASC'"
Command the panel to sort by the number of characters in the description field, and then by the contents of the description field in ASCENDING order
NOTE:
Code to define a data source for Listview buttons.
Notes on Using Image URLs With Listview Buttons
Since a Listview button can retrieve images to display as part of the Listview, the column in the data table that sets the image URL will require the server’s username and password be included as part of the image URL.
The following example represents the contents of a .CSV file that has image URLs as part of the data. The URL Path column has some URLs with using http and no authentication credentials, some using http and user/password credentials, and one using https and user/password credentials:
File Type, No, URL Path
GIF, 1, http://www.w3schools.com/images/compatible_chrome.gif
GIF, 2, http://www.w3schools.com/images/compatible_ie.gif
GIF, 3, http://www.w3schools.com/images/compatible_firefox.gif
PNG, 4, http://user:password@master-ni3100/xsimple_green.png
PNG, 5, https://user:password@master-nx1200/__AMX__icon-mute-off.png
PNG, 6, http://user:password@master-nx1200/__AMX__icon-mute-on.png
NOTE: HTTPS is supported in G5 panel firmware version v1.4.9 and higher.
NOTE: HTTPS is not supported by TPDesign5 dynamic image resources at this time.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 155
Programming - Send Commands
Streaming Video, MXA-MP, and MXA-MPL Commands
The following are NetLinx commands that control streaming video output, as well as coordinate video output to a Modero X Series
G5 touch panel from an MXA-MP Multi Preview or MXA-MPL Multi Preview Live video breakout box. The command prefix for all MXA-
MP/L commands is "^SLT-1" to match legacy Break Out Box video "slot" syntax. Slot 1 (the only supported slot) always refers to the MXA-MP/L.
Streaming Video, MXA-MP/MPL Commands
^SDM Button State Streaming Digital Media Command - Starts or stops a streaming session. Stream starts if a valid URL is specified and stops if server URL string is empty or invalid. To use this command, the current page should have one visible streaming button.
• Syntax :
"'^SDM-<addressArray>,<stateArray>,<URL>'"
• Variables :
URL :
<protocol://><host name or host ip><:video port><:optional audio port>
URL for connected MXA-MPL =
UDP://169.254.11.12:5700
Protocol could have the following values: udp = MPEG2 transport stream over UDP http = Motion JPEG (JFIF format over MIME Multipart) [Modero X Series Panels Only] rtpmpeg2 = MPEG2 elementary stream over RTP/RTCP [Modero X Series Panels do not support] rtpmpeg4 = MPEG4 elementary stream over RTP/RTCP [Modero X Series Panels do not support]
If the optional audio port is not specified, video port + 2 is used for audio.
URL for USB drive attached to the panel =
"'^SDM-<Address range>,<State range>,file:///udisk/path_to_video_file_on_usb_drive'"
The 'file:///udisk/' must be exactly as documented (there must be three '/' characters after the 'file:').
Example:
SEND_COMMAND Panel,"'^SDM-400,1,file:///udisk/Video-Clip.mp4'"
• Examples :
SEND_COMMAND 10001:2:0,"'^SDM-10,2,udp://234.4.0.4:5500'"
Sets ON state to play video on multicast address.
^SLT
^SLT reboot
^SLT start
SEND_COMMAND 10001:2:0,"'^SDM-10,1,cam://local'"
Sets OFF state to play camera.
SEND_COMMAND 10001:2:0,"'^SDM-10,1,stop'"
Stop playing the current video.
SEND_COMMAND 10001:2:0,"'^SDM-10,1,'"
Stop playing the current video.
SEND_COMMAND 10001:1:0,"'^SDM-10,1,udp://169.254.11.12:5700'"
Start playing the current video.
Note: When using the variable "udp," this must be in lower case.
Video Slot Command (aka MultiPreview Command) - Send a command to the MPL connected to the panel.
• Syntax :
"'^SLT-<device>,<subcommand>'"
• Variables : device : 1 (Device is always 1 for the MXA-MP and MXA-MPL, the only device type currently supported by Modero
X Series panels)
Subcommands : reboot , start , stop , videomode , audiovideoenable , videoinput
Slot command to reboot the MXA-MP or MXA-MPL. If previous or factory is specified, the MXA-MP/L will revert its firmware to either the previously loaded version or the factory installed version, respectively.
• Syntax :
^SLT-1,reboot=<current(default),previous,factory>
• Variables : current : Reboot to the current firmware version. If not specified, this is the version used.
previous : Reboot to the previous firmware version.
factory : Reboot to the firmware version installed by the factory.
MXA-MPL Start stream - Tells the Breakout Box to start streaming audio, video or both.
• Syntax :
"'^SLT-1,start=<audio,video,both>'"
• Variables : audio : start the stream but only stream the audio content.
video : start the stream but only stream the video content both : start the stream using both the audio and video content
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 156
Programming - Send Commands
Streaming Video, MXA-MP/MPL Commands (Cont.)
^SLT stop
^SLT videomode
^SLT audiovideoenable
^SLT videoinput
?SLT
MXA-MPL Stop stream - Tells the MXA-MPL to stop streaming.
• Syntax :
"'^SLT-1,stop'"
• Variables : None
Set the MPL output format and resolution.
• Syntax :
"'^SLT-1,videomode=<format>,<resolution>'"
• Variables : format : hdmi or dvi resolution : The resolution in the form of <horizontal>x<vertical><i|p>@<rate>
Note: When using HDMI sources, use the DIGITAL source, but with DVI and other formats, use the ANALOG source.
Set format, resolution and rate for MXA-MPL.
MXA-MPL Video enable command - Sets the option to enable video on subsequent streams from the MXA-MPL.
• Syntax :
"'^SLT-1,audiovideoenable=<video|audio|both(default)>'"
• Variable : format : video, audio, or both. The default is both .
Note: This does not work immediately; it will take effect on the next Stream start. It can still be overridden in the
"^SLT-1,start" command.
Turn on/off the video input to the MXA-MP/MPL.
• Syntax :
"'^SLT-1,videoinput=<on|off>'"
• Variable : mode : on or off.
• Examples :
SEND_COMMAND Panel, "'^SLT-1,videoinput=on'"
Turn on the video input to the MXA-MP/MPL.
SEND_COMMAND Panel, "'^SLT-1,videoinput=off'"
Turn off the video input to the MXA-MP/MPL.
Query Video Slot Command (aka Query MultiPreview) - Query the value of any status field reported by the
MXA-MP/L, such as version, serial number, MAC address, inputInfo, streamInfo, and type.
• Syntax :
"'?SLT-1,querystatus=<statusField>,[optional id]'"
Response is a custom event as follows:
• Variables : statusField : the option to get status on. Supported options are: version , serialNo , macAddress , inputInfo , streamInfo , type , temperature id : optional ID value to be placed in response so that responses can be matched to queries. If no ID is present, ID is set to 0 in the response.
The response returned is a custom event with the following properties:
Custom Event Property Value
Port port command was received on
ID 0
Type 770
Flag 0
Value 1 ID specified in command or 0 if none specified
Value 2 0
Value 3 0
Text String that represents the status
• Example :
SEND_COMMAND Panel,"'? SLT-1,querystatus=type,101'"
The following custom event values would be received from the panel if an MXA-MPL is connected:
Custom Event Property Value
Port port command was received on
ID 0
Type 770
Flag 0
Value 1 101
Value 2 0
Value 3 0
Text MXA-MPL (If an MXA-MPL is connected.
For an MXA-MP, the text would be "MXA-MP")
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 157
Programming - Send Commands
Notes on Using the ^SDM and ^SLT Commands
Based on the user’s pages, the touch panel receiving video from an MXA-MPL will initiate that video feed as necessary, based on the button receiving the video. However, if you are changing video resolution or mode, using the ^SDM or ^SLT commands may be necessary to start and stop the video. To do so:
1.
Use the ^SDM command first, with an empty URL value to stop the video.
2.
If this does not work, use ^SDM with the URL value of "169.254.11.12:5700".
3.
If neither of these options work, then and only then use ^SLT to start and stop the video.
In early firmware versions, ^SLT-1,start and ^SLT-1,stop were used to start and stop video coming from the MXA-MP. These commands are still available but using them is not recommended, as the stream is started and stopped automatically when a button that contains MXA-MPL video fill is displayed, and stopped when it is no longer in view. Showing/hiding the button state containing MXA-MPL video (e.g. via page flip, popup hide, or button state change) is the recommended way to start and stop
MXA-MPL video. However, if it becomes necessary to stop video while the button is displayed on screen (for example, if resolution needs to be changed), then the ^SDM command should be used to start and stop the video.
If a button containing MXA-MPL video must be left on screen, try the following options:
SEND_COMMAND 10001:1:0,"'^SDM-10,1,'"
(stops MXA-MPL video)
SEND_COMMAND 10001:1:0,"'^SLT-1,videomode=hdmi,640x480p@30'"
(changes MXA-MPL video resolution to 640x480 with a frame rate of 30fps)
SEND_COMMAND 10001:1:0,"'^SDM-10,1,udp://169.254.11.12:5700'"
(restarts MXA-MPL streaming)
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 158
Programming - Send Commands
VNC Commands
VNC is handled via an external application and is displayed in a window. To enable a VNC connection to a remote device, a VNC App window must be created in the TPD project.
A single window can support connections to multiple destinations, though not simultaneously. Once a window is open, the parameters such as host, username, and password can be changed via send commands.
The following send commands are available to control VNC sessions. The application window name (from TPDesign5) is used as the key to update VNC parameters. If an existing window is open, the session should be logged out first before changing any parameters to avoid undefined behavior. Once all the parameters have been changed, then login to connect with the new parameters.
VNC Send Commands
^BVG VNC Client Window update parameter command - Update parameter list.
• Syntax :
"'^BVG-<app window name>,<param list>'"
• Variables : app window name : The name of the application window to act upon.
param list : the key/value sets(s) for the VNC parametric. Key/value sets are comma separated.
^BVL
Parameter Name colorModel
Description color depth of VNC window
Values
C24bit, C256, C64, C8, C4,
C2 true,false
Default Value
C24bit
Required
No
Type
String forceFull ipAddress password port prefEncoding scaling
Request for full-screen updates server name or IP address
Authentication password server port number
Preferred server encoding
Scaling options
0 (Raw),
1 (Copy Rect Encoding),
2 (RRE Encoding),
4 (CoRRE Encoding),
5 (Hextile Encoding),
6 (Zlib Encoding),
7 (Tight Encoding),
16 (ZRLE Encoding)
0 (fit to screen),
1 (one-to-one),
2 (zoom) true, false false
5900
7 (Tight Encoding)
0 (fit to screen)
No
Yes
No
Yes
No
No
Boolean
String
String
Integer
String
Integer useLocalCursor Local mouse pointer (set to true if pointer is invisible) false No Boolean
Restart App Restart application is already running true, false true Yes Boolean
This command is a generic form of the remainder of the commands. Any parameter in the VNC App Parameter List from
TPDesign can be updated with this command by including the Key/Value pair in the list.
Note: One limitation is that no commas may be used in any of the fields. Delimiters are not escaped at this time.
• Example :
SEND_COMMAND Panel,"'^BVG-VNCClient,ipAddress=192.168.200.25,port=5901, password=myNewPassword'"
Change the application window name VNCClient to connect to server IP 192.168.200.25, port 5901 with a password of myNewPassword .
VNC Client Window login command - Login/out of an existing session. For logon, if the window is not open, the window is opened and the session is connected using the current parameters. If the window is already open, then the session is updated to new/current parameters. Logoff will close the session and window.
• Syntax :
"'^BVL-<appWindowName>,<1=logon|0=logoff>'"
• Variables : app window name : The name of the application window to act upon.
logon/logoff : 1 to logon to server, 0 to logoff
• Example :
SEND_COMMAND Panel,"'^BVL-VNCClient,0'"
Command the application window name VNCClient to logout/disconnect from the VNC server.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 159
Programming - Send Commands
VNC Send Commands (Cont.)
^BVN
^BVT
VNC Client Window Update server IP command - Update VNC server ip address/name for the application window.
• Syntax :
"'^BVN-<appWindowName>,<vnc server ip address or name>'"
• Variables : app window name : The name of the application window to act upon.
server name or ip : The server's DNS name or IP address.
• Examples :
SEND_COMMAND Panel,"'^BVN-VNCClient,192.168.200.25'"
Command the application window name VNCClient to set the VNC server to 192.168.200.25.
SEND_COMMAND Panel,"'^BVN-VNCClient,vncserver'"
Command the application window name VNCClient to set the VNC server to the server with a DNS name of vncserver.
VNC Client Window Update server port - Update VNC server port for the application window.
• Syntax :
"'^BVT-<appWindowName>,<server port>'"
• Variables : app window name : The name of the application window to act upon.
server port : The server's port.
• Example :
SEND_COMMAND Panel,"'^BVT-VNCClient,5901'"
Command the application window name VNCClient to set the VNC server port to 5901.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 160
Programming - Send Commands
MXR-1001 Send Commands
The following G5 Send Commands are supported only by MXR-1001 10.1" Modero X ® Series G5 Retractable Touch Panels:
MXR-1001 Send Commands
^MCC Motor Controller Control/Configure - This command has multiple sub-commands whose format is determined based on the first parameter. Note that after a command is sent to the motor controller which causes a change in its state, the
Panel will send status change custom events back to the master to update it with the new states.
• Syntax :
"'^MCC-<MOTOR|LOCK|AUTHENTICATION|LED>'"
• Subcommands :
"'^MCC-<MOTOR>,<RAISE|LOWER>'" - Motor Command.
Parameters:
RAISE: Used to request that the panel be raised to its highest position so that it can be put in service.
LOWER: Used to request that the panel be lowered to its lowest position (i.e. fully retracted) and taken out of service.
Example:
SEND_COMMAND Panel, "'^MCC-MOTOR,RAISE'"
This example command tells the Motor Controller to Raise the panel to its highest position. The panel will send back custom event 1602-RAISING, then custom event 1602-RAISED.
"'^MCC-<LOCK>,<ON|OFF>'" - Lock Command.
Parameters:
ON: Request that the Motor Controller lock be enabled. When in the locked state, any physical button request is sent upstream to the master for handling, unless the panel is in a transition state (i.e. not fully raised or lowered).
OFF: In the unlocked state, the physical button can still be used to raise/lower the panel.
"'^MCC-<AUTHENTICATION>,<SUCCESS|FAILURE>'" - Authentication Result Command.
Parameters:
SUCCESS: Used to report to the Motor Controller that the authentication was successful.
Note: When Netlinx code sends an Authentication Result command in response to a Raise or Lower Pending, the action will not take place until an MCC-MOTOR,RAISE (or LOWER) is sent.
FAILURE: Used to report to the Motor Controller that the authentication has failed. This message is used to display a failure (fast blink) LED pattern to the user as described in the
MXR-1001 Motor Controller LED Behavior section on page 19.
"'^MCC-<LEDBRIGHTNESS>,<on brightness (0-32)>,<off brightness (0-32)>'" - LED Brightness Command.
Parameters: on brightness: LED On brightness level; ranges from 0 (off) to 32 (max) off brightness: LED Off brightness level; ranges from 0 (off) to 32 (max)
NOTE: Any value outside the range (0-32) will be ignored. A value left blank will also be ignored.
Example:
SEND_COMMAND Panel, "'^MCC-LEDBRIGHTNESS,32,0'" // Changes On Brightness to 32 and
Off Brightness to 0
Example:
SEND_COMMAND Panel, "'^MCC-LEDBRIGHTNESS,,5'" // On brightness is unchanged;
change Off Brightness to 5
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 161
Programming - Send Commands
MXR-1001 Send Commands (Cont.)
?POS
Panel Position Query - Requests the current position of the panel. The “id” parameter is optional and can be used to provide a unique identifier for the message that will be echoed back by the custom event.
Note: This Custom event is always sent with Port = 1.
Syntax:
"'?POS-<id>'"
The response returned is a custom event (Custom event type 1602 ) with the following properties:
Custom Event Property Value
Port 1
ID ID (from query) echoed back, or 0 if undefined or unsolicited
Type 1602
Flag Unsolicited (0|1)
Value 1 State Value (see below)
Value 2 Locked (0|1)
Value 3 reserved for future use
Text State String (see below)
• The ID field reports the message ID. If the custom event is being sent unsolicited, it will always be 0. If the custom event is being sent in response to a query, the “id” field of the query will be echoed back. If no “id” was specified in the query, the “ID” will be reported as 0.
ID
0
Description
The Custom Event is being sent as an unsolicited message either to report initial state (after an Online) or to report a Motor Controller state change, OR no “id” was specified in the ?POS query, OR an “id” of 0 was specified in the ?POS query (not recommended).
>0 The Custom Event is being sent in response to a query, and this field contains the value that was passed as a parameter in the ?POS query.
• The Flag field reports whether the custom event is being sent as an unsolicited message, or is being sent in response to a query.
Flag
0
1
Description
This custom event is NOT unsolicited, meaning it is being sent in response to a query.
This custom event is being sent Unsolicited either to report initial status (after an online) or to report a status change in the Motor Controller.
• Value1 (State Value) and Text (State String) Values:
Value1 Text Description
0 ERROR State is unknown, or there is an error in the Motor Controller
An Error Description may be provided in the form ERROR<code>-<description>.
1
2
3
4
5
6
7
8
RAISED
LOWERED
RAISING
LOWERING
Panel is stationary and is raised to its highest position
Panel is stationary and is lowered to its lowest position
Panel is in the process of raising, but has not yet reached the highest position.
Panel is in the process of lowering to its lowest position.
STALLED-LOWERING Panel has stalled while lowering and is somewhere between its lowest and highest position.
STALLED-RAISING Panel has stalled while raising and is somewhere between its lowest and highest position.
STALLED-UNKNOWN Panel has stalled, but it is unknown whether it was in the process of raising or lowering. It is somewhere between its lowest and highest position.
RAISE-PENDING A panel raise has been requested via physical button, but the lock feature is enabled and authentication is required prior to acting on the request.
9 LOWER-PENDING A panel lower has been requested via physical button, but the lock feature is enabled and authentication is required prior to acting on the request.
Note: If any fault is present, an Error Mask will be appended to the Text above after a comma. The format of the Error Mask
is the same as in the ONERROR data event described on page 163.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 162
Programming - Send Commands
MXR-1001 Send Commands (Cont.)
?POS
(Cont.)
• The Value2 field reports whether the physical button on the Motor Controller is locked or not. If locked, it is expected that Netlinx code will handle requests to raise/lower the panel.
Value2 Description
0 The lock feature is currently Disabled, meaning no authentication or approval from Netlinx code is required, and requests to raise/lower the panel can be handled locally at the Motor Controller.
1 The lock feature is currently Enabled, meaning all Motor Controller button presses must be passed to the
Master prior to being acted upon.
• The Value3 field is reserved for future use.
Example (as reported in Netlinx Studio Notifications):
Custom Event [14222:1:1]-ID=0 Type=1602 Flag=1 Value1=6 Value2=0 Value3=0
Text: STALLED-RAISING,Error=0x0008
This custom event indicates that an unsolicited position change is being reported on device 14222 on System 1.
The new state being reported is state 6, STALLED-RAISING, and a "Stall Winding - B" (error code 3) fault is present.
Data Event - ONERROR
In addition to the Custom Event being sent whenever the Motor Controller's state changes, an ONERROR Data event will also be generated for a change in any error condition (this includes new faults reported, or clearing of previously reported faults).
Note that the State does not necessarily have to be ERROR in order to report an error condition. For example, when the panel is in the STALLED-RAISING or STALLED-LOWERING state, an error will typically be reported via ONERROR data event. Also, it is possible that multiple errors could be present simultaneously. For example, a thermal warning could be present, and a subsequent stall be caused by the user pressing the button.
The fields reported by the ONERROR Data event are as follows:
Data.Device.Port
= 1
Data.Number = State Value (same as Value1 in the custom event above).
Data.Text
= <State Value>,<State String>,Error=<Error Mask>
Where:
State Value is the same as the State Value in the Data.Number field.
State String is the same as the text in the position custom event (above).
Error Mask is a 16-bit mask in hexadecimal format, with one bit representing each possible error code.
The following table enumerates the error code layout within the mask:
Error Code Layout
Bit Position Error Code
1
0
3
2
5
4
7
6
9
8
11
10
15
14
13
12 reserved reserved reserved reserved
LIMIT_SWITCH_ERROR
COMM_ERROR
CHIP_ERROR
EEPROM_ERROR
THERMAL_SHUTDOWN
THERMAL_WARNING
OVER_CURRENT
STALL_TIMEOUT
STALL_WINDING_B
STALL_WINDING_A
USER_INTERVENTION
AUTH_TIMEOUT
When the Motor Controller reports an error, it will fast-blink the user-visible button LED until the fault clears. Note that some errors are momentary
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 163
Programming - Send Commands
ONERROR Error Codes
When a relevant error status is reported in the Panel, the backlight, touch and microphone will be re-enabled so that the panel could still be used if it can be accessed (for example, via the manual release mechanism). Not all errors cause the touch/backlight/
microphone to be re-enabled (see the ONERROR Error Codes table below).
ONERROR Error Codes
Error Code
(bit position in mask)
0
Error
No Error
1
Description Recovery
Momentary error - no action required
Backlight/Touch
Enabled
YES
NO
2
3
4
5
6
7
Authorization Timeout User initiated action via pushbutton, but the lock feature was enabled and the
Master did not respond to the request.
User Intervention The panel motor was stopped prematurely by the user pressing the pushbutton.
Stall Winding - A
Stall Winding - B
The panel motor has stalled due to winding A.
The panel motor has stalled due to winding B.
Stall Timeout
Over Current
Thermal Warning
A stall has been detected based on the fact that the limit switch has not been triggered within the last12 seconds.
An over-current condition has been detected in the motor.
A high temperature condition has been detected in the motor (warning only).
Momentary error - no action required
Information only - no action required
Information only - no action required
Press the pushbutton or use Netlinx code to send a command to Raise or
Lower the panel.
TBD
NO
YES
YES
YES
YES
NO
8
Information only - no action required.
However, this error indicates that the
Motor Controller may be close to a
Thermal Shutdown (see below).
Power down the unit for XX minutes to allow the motor to cool. If the condition persists, contact technical support.
YES
9
10
11
12
Thermal Shutdown
EEPROM Error
Chip Error
A temperature above the shutdown threshold has been detected in the motor.
The motor cannot be engaged until the fault is cleared.
The Motor Controller was not able to access the EEPROM.
There is a problem with the Motor
Controller chip (L6470).
Communication Error Communication between the panel and
Motor Controller has been lost.
Limit Switch Error The upper and lower limit switches are reporting conflicting status (i.e. reflecting that the panel is both raised and lowered simultaneously).
Power cycle the unit. If the condition persists, contact technical support.
Power cycle the unit. If the condition persists, contact technical support.
Information only - no action required.
When this error occurs, the Motor
Controller automatically disables the
"Lock" setting (if previously enabled) so that the panel can be raised or lowered without communicating with the Master. The panel continuously attempts to restore communication with the Motor Controller, and will reset it after 3 failed attempts.
If the condition persists, contact technical support.
Momentary error - no action required.
If the condition persists, contact technical support.
NO
YES
YES
YES
NOTE: In the rare event of an error in which panel position cannot be determined, or after a power outage while panel is in an intermediate state, the panel will be retracted.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 164
Programming Numbers
Color Table
Color Table
42
43
44
38
39
40
41
34
35
36
37
30
31
32
33
26
27
28
29
22
23
24
25
18
19
20
21
14
15
16
17
10
11
12
13
8
9
6
7
Index No.
Name
0 Very Light Red
1 Light Red
4
5
2
3
Red
Medium Red
Dark Red
Very Dark Red
Very Light Orange
Light Orange
Orange
Medium Orange
Dark Orange
Very Dark Orange
Very Light Yellow
Light Yellow
Yellow
Medium Yellow
Dark Yellow
Very Dark Yellow
Very Light Lime
Light Lime
Lime
Medium Lime
Dark Lime
Very Dark Lime
Very Light Green
Light Green
Green
Medium Green
Dark Green
Very Dark Green
Very Light Mint
Light Mint
Mint
Medium Mint
Dark Mint
Very Dark Mint
Very Light Cyan
Light Cyan
Cyan
Medium Cyan
Dark Cyan
Very Dark Cyan
Very Light Aqua
Light Aqua
Aqua
0
0
0
0
64
48
0
0
191
159
127
95
128
112
96
80
255
223
191
159
127
95
255
223
Red
255
223
191
159
127
95
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
127
95
255
223
191
159
127
95
191
159
127
95
255
223
191
159
128
112
96
80
64
48
255
223
Green
0
0
0
0
0
0
191
159
127
95
128
112
96
255
223
191
159
127
95
255
223
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Blue
0
0
0
0
0
0
191
159
127
95
255
223
191
128
112
96
80
64
48
255
223
Name
Medium Aqua
Dark Aqua
Very Dark Aqua
Very Light Blue
Light Blue
Blue
Medium Blue
Dark Blue
Very Dark Blue
Very Light Purple
Light Purple
Purple
Medium Purple
Dark Purple
Very Dark Purple
Very Light Magenta
Light Magenta
Magenta
Medium Magenta
Dark Magenta
Very Dark Magenta
Very Light Pink
Light Pink
Pink
Medium Pink
Dark Pink
Very Dark Pink
White
Grey1
Grey3
Grey5
Grey7
Grey9
Grey4
Grey6
Grey8
Grey10
Grey12
Grey13
Grey2
Grey11
Grey14
Black
TRANSPARENT
71
72
73
74
67
68
69
70
63
64
65
66
59
60
61
62
55
56
57
58
51
52
53
54
Index No.
45
46
47
48
49
50
83
84
85
86
87
255
79
80
81
82
75
76
77
78
Programming - Send Commands
0
255
238
204
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Green
80
64
48
0
0
0
34
221
68
17
0
53
170
136
102
187
153
119
85
51
223
191
159
127
95
255
238
204
48
255
223
191
159
127
95
255
0
0
0
128
112
96
80
64
0
0
0
0
Red
0
0
34
221
68
17
0
99
170
136
102
187
153
119
85
51
112
96
80
64
48
255
238
204
95
255
223
191
159
127
95
128
159
127
95
255
223
191
159
127
Blue
159
127
95
255
223
191
34
221
68
17
0
99
170
136
102
187
153
119
85
51
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 165
Justification Values
Button State Number Justification Value
Justification
Absolute
Justification Value
0 top-left top-middle top-right center-left center-middle center-right bottom-left bottom-center bottom-right scaled-to-fit scale-maintain-aspect-ratio
7
8
5
6
3
4
1
2
9
10
11 none none none none none none none
Justification parameters
0,<x offset,y offset> none none none none
Programming - Send Commands
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 166
Programming - Send Commands
Border Styles
Border Styles
# Border Style
1 None
2 AMX Elite -L
3 AMX Elite -M
4 AMX Elite -S
5 Bevel -L
6 Bevel -M
7 Bevel -S
8 Circle 15
9 Circle 25
10 Circle 35
11 Circle 45
12 Circle 55
13 Circle 65
14 Circle 75
15 Circle 85
16 Circle 95
17 Circle 105
18 Circle 115
19 Circle 125
20 Circle 135
21 Circle 145
22 Circle 155
23 Circle 165
24 Circle 175
25 Circle 185
26 Circle 195
27 Cursor Bottom
28 Cursor Bottom w/hole
29 Cursor Top
30 Cursor Top w/hole
31 Cursor Left
32 Cursor Left w/hole
33 Cursor Right
34 Cursor Right w/hole
35 Custom Frame
36 Diamond 15
37 Diamond 25
38 Diamond 35
39 Diamond 45
40 Diamond 55
# Border Style
41 Diamond 65
42 Diamond 75
43 Diamond 85
44 Diamond 95
45 Diamond 105
46 Diamond 115
47 Diamond 125
48 Diamond 135
49 Diamond 145
50 Diamond 155
51 Diamond 165
52 Diamond 175
53 Diamond 185
54 Diamond 195
55 Double Bezel -L
56 Double Bezel -M
57 Double Bezel -S
58 Double Line
59 Fuzzy
60 Glow -L
61 Glow -S
62 Help Down
63 Neon Active -L
64 Neon Active -S
65 Neon Inactive -L
66 Neon Inactive -S
67 Oval H 60x30
68 Oval H 100x50
69 Oval H 150x75
70 Oval H 200x100
71 Oval V 30x60
72 Oval V 50x100
73 Oval V 75x150
74 Oval V 100x200
75 Picture Frame
76 Quad Line
77 Single Line
78 Windows Style Popup
79 Windows Style Popup (status bar)
80 Menu Btm Rounded 15
# Border Style
81 Menu Btm Rounded 25
82 Menu Btm Rounded 35
83 Menu Btm Rounded 45
84 Menu Btm Rounded 55
85 Menu Btm Rounded 65
86 Menu Btm Rounded 75
87 Menu Btm Rounded 85
88 Menu Btm Rounded 95
89 Menu Btm Rounded 105
90 Menu Btm Rounded 115
91 Menu Btm Rounded 125
92 Menu Btm Rounded 135
93 Menu Btm Rounded 145
94 Menu Btm Rounded 155
95 Menu Btm Rounded 165
96 Menu Btm Rounded 175
97 Menu Btm Rounded 185
98 Menu Btm Rounded 195
99 Menu Top Rounded 15
100 Menu Top Rounded 25
101 Menu Top Rounded 35
102 Menu Top Rounded 45
103 Menu Top Rounded 55
104 Menu Top Rounded 65
105 Menu Top Rounded 75
106 Menu Top Rounded 85
107 Menu Top Rounded 95
108 Menu Top Rounded 105
109 Menu Top Rounded 115
110 Menu Top Rounded 125
111 Menu Top Rounded 135
112 Menu Top Rounded 145
113 Menu Top Rounded 155
114 Menu Top Rounded 165
115 Menu Top Rounded 175
116 Menu Top Rounded 185
117 Menu Top Rounded 195
118 Menu Rt Rounded 15
119 Menu Rt Rounded 25
120 Menu Rt Rounded 35
# Border Style
121 Menu Rt Rounded 45
122 Menu Rt Rounded 55
123 Menu Rt Rounded 65
124 Menu Rt Rounded 75
125 Menu Rt Rounded 85
126 Menu Rt Rounded 95
127 Menu Rt Rounded 105
128 Menu Rt Rounded 115
129 Menu Rt Rounded 125
130 Menu Rt Rounded 135
131 Menu Rt Rounded 145
132 Menu Rt Rounded 155
133 Menu Rt Rounded 165
134 Menu Rt Rounded 175
135 Menu Rt Rounded 185
136 Menu Rt Rounded 195
137 Menu Lt Rounded 15
138 Menu Lt Rounded 25
139 Menu Lt Rounded 35
140 Menu Lt Rounded 45
141 Menu Lt Rounded 55
142 Menu Lt Rounded 65
143 Menu Lt Rounded 75
144 Menu Lt Rounded 85
145 Menu Lt Rounded 95
146 Menu Lt Rounded 105
147 Menu Lt Rounded 115
148 Menu Lt Rounded 125
149 Menu Lt Rounded 135
150 Menu Lt Rounded 145
151 Menu Lt Rounded 155
152 Menu Lt Rounded 165
153 Menu Lt Rounded 175
154 Menu Lt Rounded 185
155 Menu Lt Rounded 195
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 167
Programming - Send Commands
ISO-8859-1 Character Encoding/Decoding table
ISO-8859-1 Character Encoding/Decoding
Character value
(decimal)
Character value
(hex)
^TXT and ^UTF interchangeable
Yes
No
ASCII
Latin-1
(Windows-1252 remap range)
Latin-1
Unicode
0-127
128-159
160-255
>255
0x00-0x7F
0x80-0x9F
0xA0-0xFF
>0xFF
Resource Escape Codes
Resource Escape Codes
Sequence
$DV
$SY
Panel Information
Device number
System number
$IP
$HN
$MC
$PX
$PY
$ST
$AC
IP address
Host name
MAC address
X resolution of current panel mode/file
Y resolution of current panel mode/file
Current state
Address code
No
No
Sequence
$AP
$CC
$CP
$LC
$LP
$BX
$BY
$BN
?TXT Response Flag in
Backwards Compatibility
Mode (^ENC-1 was sent)
0 (Latin-1)
1 (Hex-quad)
0 (Latin-1)
1 (Hex-quad)
?TXT Response
Flag in default
(UTF-8) Mode
2 (UTF-8)
2 (UTF-8)
2 (UTF-8)
2 (UTF-8)
Panel Information
Address port
Channel code
Channel port
Level code
Level port
X resolution of current button
Y resolution of current button
Name of button
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 168
Virtual Keystroke Commands
Virtual Keystroke Commands
60
61
62
63
56
57
58
59
52
53
54
55
48
49
50
51
68
69
70
71
64
65
66
67
72
73
44
45
46
47
40
41
42
43
36
37
38
39
32
33
34
35
28
29
30
31
24
25
26
27
20
21
22
23
16
17
18
19
12
13
14
15
8
9
10
11
6
7
4
5
2
3
Keycode
1
,
Z
X
Y
T
U
V
W
.
Alt-L
Alt-R
Shift-L
Shift-R
TAB
Space
Sym
R
S
P
Q
N
O
L
M
J
K
I
H
F
G
D
E
]
\
Explorer
Envelope
Enter
Delete
[
_
Grave
-
7
8
5
6
3
4
1
2
Key
Soft-L
Soft-R
Home
Back
Call
End Call
0
9
*
#
DPad-U
DPad-D
DPad-L
DPad-R
DPad-Center
Vol Up
Vol Dn
Power
Camera
B
C
Clear
A
129
130
131
132
133
134
135
136
121
122
123
124
125
126
127
128
137
138
139
140
141
142
143
144
145
146
113
114
115
116
117
118
119
120
105
106
107
108
109
110
111
112
97
98
99
100
101
102
103
104
93
94
95
96
89
90
91
92
85
86
87
88
81
82
83
84
77
78
79
80
Keycode
74
75
76
Button R2
Button Thumb L
Button Thumb R
Button Start
Button Select
Button Mode
Escape
Forward Delete
Ctrl-L
Ctrl-R
Caps Lock
Scroll Lock
Meta L
Meta R
Function
SysReq / Print Screen
Break
Move Home
Move End
Insert
Forward
Media Play
Media Pause
Media Close
F3
F4
F5
F6
Media Eject
Media Record
F1
F2
F7
F8
F9
F10
F11
F12
Num Lock
Numpad 0
Numpad 1
Numpad 1
;
Key
Apostrophe
/
@
Num
Headset Hook
Focus
+
Menu
Notification
Search
Media Play/Pause
Media Stop
Media Next
Media Prev
Media Rew
Media FF
Mute
Page Up
Page Down
Pict Symbols
Switch Charset
Button A
Button B
Button C
Button X
Button Y
Button Z
Button L1
Button R1
Button L2
Programming - Send Commands
TV Input
STB Power
STB Input
AVR Power
AVR Input
Prog Red
Prog Green
Prog Yellow
Prog Blue
App Switch
Button 1
Button 2
Button 3
Button 4
Button 5
Button 6
Button 7
Button 8
Button 9
Button 10
Button 11
Button 12
Button 13
Button 14
Button 15
Button 16
Language Switch
Manner Mode
3D Mode
Contacts
Calendar
Music
Calculator
Zenkaku Hankaku
Eisu
Mhenkan
Henkan
Katakana Hiragana
Yen
Ro
Kana
Assist
Key
Numpad 3
Numpad 4
Numpad 5
Numpad 6
Numpad 7
Numpad 8
Numpad 9
Numpad /
Numpad *
Numpad -
Numpad +
Numpad .
Numpad ,
Numpad Enter
Numpad =
Numpad (
Numpad )
Volume Mute
Info
Chan Up
Chan Down
Zoom In
Zoom Out
TV
Window
Guide
DVR
Bookmark
Bookmark
Settings
TV Power
202
203
204
205
206
207
208
209
194
195
196
197
198
199
200
201
210
211
212
213
214
215
216
217
218
219
186
187
188
189
190
191
192
193
178
179
180
181
182
183
184
185
170
171
172
173
174
175
176
177
162
163
164
165
166
167
168
169
154
155
156
157
158
159
160
161
Keycode
147
148
149
150
151
152
153
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 169
SSH Commands
SSH Commands
Overview
The panel has a SSH server that listens for connections on port 22 . The SSH server can be enabled and disabled in the Settings menu. To connect, the SSH client must provide a user and password. The user is " amx " and the password is the Configuration
Password used in the Settings menu on the panel.
The SSH server provides a shell that allows for commands to be entered and also has an interactive menu for many commands.
SSH Commands
help
?
back clear date
Displays this help or help about a command
Syntax :
*:help [command]
Arguments : command
The command for which help is needed.
Issue the 'BACK' keystroke to the system.
Syntax :
*:back [options]
Options :
--help
Display this help message
Clears the console buffer.
Syntax :
*:clear
Gets/sets the current system date. An interactive menu is available when using the set proxy (i.e. "set date").
Syntax :
*:date [options] [date]
Arguments : date
New date in format: YYYY-MM-DD
Options :
--config, -c, --set
Set the system date.
--day, -d
Day of month (1-31, defaults to -1),
--help
Display this help message
--info, -?
Display the current date on screen.
--month, -m
Month (1-12, defaults to -1).
--verbose, -v
Display verbose date information.
--year, -y
Year (XXXX, defaults to -1).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 170
SSH Commands
SSH Commands (Cont.)
debug echo logout exit quit g5:cache
View/set debug level for 'msg' logging. An interactive menu is available when using the set proxy (i.e. "set debug").
Syntax :
*:debug [options] [action]
Arguments : action: enable or disable mode action to perform
'enable', 'on': enable debug mode.
'disable','off': disable debug mode.
Options :
--config, -c, --set
Set the debug level.
--disable, -d, --off, -F
Disable debug mode.
--enable, -e, --on, -N
Enable debug mode.
--help
Display this help message
--info, -?
Display the current debug level.
Echoes or prints arguments to STDOUT.
Syntax :
*:echo [options] [arguments]
Arguments : arguments
Arguments to display separated by whitespaces.
Options :
--help
Display this help message.
--newline, -n
Do not print the trailing newline character.
Terminate the command shell session.
Syntax
*:logout g5:config g5:profile g5:prof
Cache command - dump or purge cache contents.
Syntax
G5:cache [options]
Options :
--help
Display this help message.
-purge
Purge.
-verbose, -v, -vb
Verbose.
Display configuration information for NetLinx and IP.
Syntax : g5:config [options]
Options :
--help
Display this help message.
--info, -i
Return configuration info.
Dumps profile configuration (all profiles if none specified)
Syntax :
G5:profile [options]
Options :
--help
Display this help message
-name
Profile name to dump
-verbose, -v, -vb verbosity (currently 1 or 2)
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 171
SSH Commands (Cont.)
g5:sensor g5:settings g5:setup g5:touch g5:version g5:ver g5:webu
Sensor commands.
Syntax :
G5:sensor [options] sensor
Arguments : sensor
Target sensor <motion|light>
Options :
--help
Display this help message.
-calibrate, -c
Calibrate light sensor.
-enable, -e
Enable.
-thresh, -t
Threshold.
Display the panel settings.
Syntax :
G5:settings [options] [category]
Arguments : category
Settings category to display (all, status, sound, master, config, sensors, ethernet)
Options :
--help
Display this help message.
--info, -?
Display the current settings.
Launch the panel settings utility.
Syntax :
G5:setup [options]
Options
--help
Display this help message
Touch panel overlay self test and diagnostics.
Syntax :
G5:touch [options] [watchEnable]
Arguments watchEnable
Optional 'on'/'off' to enable/disable persistent diagnostics watching.
Options
--help
Display this help message
--watchTime, -w
Time interval for watching overlay diagnostics in seconds (default is 1).
Display the G5 version.
Syntax :
G5:version [options]
Options :
--help
Displays this help message
Start a firmware update from a web server.
Syntax :
G5:webu [options] url
Arguments : url
URL to the firmware kit file, including the http://server/kit-filename.
Options :
--help
Display this help message
SSH Commands
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 172
SSH Commands
SSH Commands (Cont.)
g5:window-stats g5:ws get history ip key man
Get the application window statistics.
Syntax :
G5:window-stats [options] [package]
Arguments : package
A package to filter on.
Options :
--help
Display this help message
Get information about a specific target provided as an argument. Acts on any command that has the --info option.
Syntax
*:get arguments
Arguments arguments
Command arguments to pass through.
Prints command history.
Syntax :
*:history
Gets/sets the IP settings of the device. An interactive menu is available when using the set proxy (i.e. "set ip").
Syntax :
*:ip [options]
Options :
--config, -c, --set
Configure the ip info interactively.
--dns1, -d1
The IP address of the primary DNS server.
--dns2, -d2
The IP address of the secondary DNS server.
--domain, -dn
The domain name for the network.
--gateway, -gw
The IP address of the gateway.
--help
Display this help message.
--hostname, -hn
The hostname for the device. (Alpha-numeric values and no spaces. Dashes are OK.)
--info, -?
Display the current IP settings.
--ipaddress, -ip
The static IP address for the device
--mode, -m
Set the connection mode. (DHCP, Static)
--reset, -r
Reset IP settings to factory default.
--subnetmask, -sm
The subnet mask address for the device
Issue a keystroke to the system.
Syntax :
*:key [options] [keystroke]
Arguments : keystroke: The keystroke to issue. (Multiple keystrokes may be included.)
Options :
--help
Display this help message
--info, -?
List available keystroke names
Displays this help or help about a command.
Syntax :
*:man [command]
Arguments : command
The command to get help for.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 173
SSH Commands
SSH Commands (Cont.)
motor
(MXR-1001 only)
Displays Motor Controller Status.
Caution: The motor SSH command and subcommands are intended for diagnostic purposes only and should only be used by expert users.
Syntax :
G5:motor [options] [action] [regAddr] [regVal]
Arguments action
Action type
[dumpEepromReg|dumpMainMotorChipReg|dumpDoorMotorChipReg|writeEepromReg|
writeMainMotorChipReg|writeDoorMotorChipReg]
regAddr
hex register address (0x01 to 0x19 for motor chip; 0x00 to 0xff for EEPROM)
regVal
hex value to write to motor controller register
Options
--help
Display this help message
-calibrate, -vc, -visual
Start Visual Calibration
-diagnostic, -di, -diag, -sd
Send diagnostic to panel
-dooradjust, -d, -da, -cd
Calibrate the closure of the door when panel is lowered
-emulate, -e
Emulate a motor controller status change
-lock, -l
Set the Lock state (0=Unlocked;1=Locked)
-lower, -lo
Lower the panel
-override, -o
Override the Motor State
-paneladjust, -p, -c, -pa, -cp
Calibrate the panel position when raised
-raise, -r
Raise the panel
-verbose, -v, -vb
Print detailed statistics info
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 174
SSH Commands
SSH Commands (Cont.)
msg Enable/disable diagnostics message logging. An interactive menu is available when using the set proxy (i.e. "set msg").
Syntax :
*:msg [options] [instruction] [filters]
Arguments : instruction
Diagnostics message command instruction.
'once': display the diagnostics messages one time and exit
'on': enable diagnostics messages
'off': disable diagnostics messages
'filter': sets optional log filters (provided by filters argument)
'add': add optional log filters (provided by filters argument)
'remove': removed optional log filters (provided by filters argument)
'clear': clear optional log filters
'delete': delete current log filters
Optional log message filters (separated by spaces).
Options :
--add-filter, -af
Add a filter to the current diagnostics log filters.
--clear-filter, -cf
Remove all filters from diagnostics logging.
--clear-history, -ch, -d
Delete the diagnostics log history.
--config, -c, --set
Enable/disable diagnostics message output.
--filter, -f
Optional log message filter.
--help
Display this help message
--info, -?
Display current diagnostic message output status.
--off, -F, --disable, --stop
Disable diagnostics message output.
--on, -N, --enable, --start
Enable diagnostics message output.
--remove-filter, -rf
Remove one or more filters form the current diagnostics log filter.
--show-filter, -sf
Display all existing filters applied to diagnostics logging.
--verbose, -v
Display verbose diagnostics message status information.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 175
SSH Commands
SSH Commands (Cont.)
netlinx ping reboot scope
Gets/sets the NetLinx ICSP connection settings. An interactive menu is available when using the set proxy (i.e. "set netlinx").
Syntax :
*:netlinx [options]
Options :
--clear-credentials, -cc
Clear the username and password settings.
--config, -c, --set
Set NetLinx (ICSP) connection settings.
--device, -d
Set the device number.
--help
Display this help message.
--info, -?
Display the current NetLinx settings.
--mode, -m
Set the connection mode (AUTO, URL, LISTEN).
--password, -pw
Set the password for secure mode.
--reset, -r
Reset NetLinx settings to factory default.
--system, -s
Set the system number.
--url, -u
Set the URL of the master controller.
--username, -un
Set the username for secure mode.
Test TCP/IP network connectivity with another IP address.
Syntax :
*:ping [options] address
Arguments : address
IP Address or URL.
Options :
--help
Display this help message.
--retry-count, -c
Retry Count (number of packets).
--timeout, -w
Reboot the device.
Syntax :
*:reboot [options]
Options :
--help
Display this help message.
--silent, -s, -Y
Do not prompt for confirmation; proceed with reboot.
Switch to an alternate command namespace scope. An interactive menu is available when using the set proxy (i.e.
"set scope").
Syntax :
*:scope [options] [namespace]
Arguments : namespace
The targeted namespace scope to switch to.
Options :
--config, -c
Prompt the user to configure a new scope.
--help
Display this help message
--info, -?
Display the current scope.
--reset, -r
Reset the current scope to the default scope.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 176
SSH Commands
SSH Commands (Cont.)
set support temp
Set the configuration for a specific command provided as an argument. Acts on any command that has the --config option.
Syntax :
*:set command
Arguments : command
Command to set values and command arguments.
Support utility command. Allows capturing of system runtime status.
Syntax :
*:support [options] [instruction] [params]
Arguments : instruction
Support command instruction.
'bug-report': Print bug report. Includes dump-log, dump-system, and kernel-msg.
'dump-log': Print current logs.
'dump-system': Print system data for running services.
'kernel-msg': Print kernel messages.
params
Optional instruction parameters. See details on exact commands in OS docs.
Options :
--help
Display this help message
Report the device temperature in Celsius.
Syntax :
*:temp [options] [monitor]
Arguments : monitor
Optional 'on'/'off' to enable/disable continuous temperature monitoring.
Options :
--help
Display this help message
--info, -?
Display current system temperature.
--interval, -w, -i
Time interval for continuous temperature monitoring in seconds (default is 5).
--off, -F, --disable, --stop
Disable continuous temperature monitoring.
--on, -N, --enable, --start
Enable continuous temperature monitoring.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 177
SSH Commands
SSH Commands (Cont.)
time Gets/sets the current system time. An interactive menu is available when using the set proxy (i.e. "set time").
Syntax :
*:time [options] [time] [ampm]
Arguments : time
New time in format: 00:00:00 ampm
AM or PM (not needed if using 24 hour format).
Options :
--am, -am
AM (used when setting time)
--config, -c, --set
Set the system time.
--help
Display this help message
--hour, -h
Hour (0-24, defaults to -1)
--info, -?
Display the current time on screen.
--millisecond, -ms
Millisecond (0-999,defaults to -1).
--minute, -m
Minute (0-59, defaults to -1)
--pm, -pm
PM (used when setting time)
--second, -s
Second (0-59, defaults to -1)
--verbose, -v
Display verbose time information.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 178
Appendix A: Upgrading Firmware via NetLinx Studio
Appendix A: Upgrading Firmware via NetLinx Studio
Overview
The latest firmware (*.kit) file for each panel is available to download from www.amx.com. To download firmware files, go to the catalog page for your panel type, and click the link under "Firmware Files" on the right side of the catalog page. The ZIP file that is downloaded via this link contains the firmware (*.kit) file that can be loaded on the panel, as well as release notes and any relevant programming instructions.
NetLinx Studio 4
The latest version (4.x) of the NetLinx Studio software program is available to download from www.amx.com:
1.
Go to Products > Integration Software > Development Tools and click on NetLinx Studio to open the NetLinx Studio catalog page.
2.
Click the NetLinx Studio 4
link download the installation file (FIG. 156):
Click to download the NetLinx Studio 4 installation file
FIG. 156 NetLinx Studio v4 download links on www.amx.com
NOTE: The following instructions assume that the G5 touch panel is connected and communicating with a NetLinx Master, and that communication with the master has been established in NetLinx Studio. Refer to NetLinx Studio online help and the NetLinx Studio 4
Instruction Manual for instructions on using NetLinx Studio.
Upgrading Firmware via NetLinx Studio (v4 or Higher)
G5 touch panels use an Ethernet connection for programming, firmware updates, and touch panel file transfer via NetLinx Studio. If you have access to the panel’s network, you may transfer files directly to the panel through NetLinx Studio.
NetLinx Studio features the ability to transfer G5 firmware files directly to a G5 touch panel via HTTP (via a stand-alone web server).
This feature is provided to shorten the amount of time required for transferring a G5 *.kit file by removing the NetLinx Master from the transfer path.
*.kit files for G5 panels contain a token to signify to NetLinx Studio that a web server file transfer can take place, as indicated in the file information window of the S end To NetLinx Device dialog:
Look for " **** HTTP File Transfer Capable **** " at the end of the file (see FIG. 159 on page 180).
When NetLinx Studio detects that the file is a G5 *.kit file, it will automatically attempt to send the file via HTTP (using the standalone web server that is started by NetLinx Studio).
1.
In NetLinx Studio, open the Online Tree tab of the Workspace bar.
2.
Under System
, select a G5 panel for the firmware update (FIG. 157):
FIG. 157 NetLinx Studio Online Tree (MXT-1001 selected)
3.
Right-Click on the G5 panel, and select Firmware Transfer
from the context menu (FIG. 158):
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 179
Appendix A: Upgrading Firmware via NetLinx Studio
FIG. 158 NetLinx Studio Online context menu (Firmware Transfer selected)
This invokes the Send To NetLinx Device dialog.
4.
Under Location . click the Browse (...) button to locate and select the directory containing the G5 firmware (*.kit) file that will be transferred, in the Browse For Folder dialog.
5.
Click OK to close the Browse For Folder dialog and populate the Files window with a listing of *.kit files found in the selected folder.
6.
In the Files window, click to select the G5 *.kit file to transfer (FIG. 159):
FIG. 159 NetLinx Studio - Send to NetLinx Device dialog
7.
Click Send
FIG. 160 NetLinx Studio - Send to NetLinx Device dialog (Progress bars indicating an active firmware file transfer)
8.
The Panel will display the Message " Updating System Files ", then restart itself.
9.
The Installing System Update page will be displayed on the panel until the firmware upgrade process is complete. At this point, the panel will reboot and open it’s home page.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 180
Appendix A: Upgrading Firmware via NetLinx Studio
HTTP Server Transfer Error
If an error occurs during this type of transfer, then the HTTP Server Transfer Error dialog is invoked (FIG. 161):
FIG. 161 NetLinx Studio v3.4 or higher - HTTP Server Error dialog
In this case, there are two options for proceeding with the firmware transfer:
Select Transfer the KIT File via the NetLinx Master Controller (legacy KIT file transfer method)... to proceed using the standard (non-HTTP) method used for other NetLinx Devices (via the master controller) when OK is clicked. Note that depending on network speed and the size of the *.kit file, this method could take up to 20-30 minutes to complete. More specifically, timed tests indicate that it takes approximately 60 seconds per 9.5MB of a *.kit file to transfer.
The following table indicates the approximate length of time to send a *.kit file via the legacy file transfer method:
File Size
0-150MB
Time Required to Complete Transfer (legacy file transfer method)
10 - 15 minutes
150-200MB 15 - 20 minutes
200-250MB 20 - 25 minutes
250-300MB 25 - 30 minutes
300-350MB 30 - 35 minutes
>350MB > 35 minutes
By default, Change the HTTP Port used to transfer the KIT file...
is selected. Use this option to change the HTTP port assignment, in cases where the IP port (default = 80) is in conflict or blocked on the PC. This option will restart the web server with a different HTTP port assignment and restart the file transfer when OK is clicked.
Select the appropriate option and click OK to restart the file transfer.
Click Cancel to cancel the current file transfer.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 181
Appendix B: Using NetLinx to Define a Data Source (Listview Buttons)
Appendix B: Using NetLinx to Define a Data Source
(Listview Buttons)
Example Listview Workflow - NetLinx Data Source
The following section describes an example workflow for implementing a Listview button that uses NetLinx code as the data source.
The use case for this example is that of a contact list for a SIP phone system. In this case, the user finds and presses a contact on the screen to initiate the call.
The workflow in this example describes each step required to implement a data source for a Listview button via NetLinx Code:
1.
Creating a Listview button on a G5 panel page and set button properties
2.
Creating a data source in NetLinx code
3.
Configuring and populating the Listview
4.
Configuring a response to a user selection
1) Create the Listview Button and Set Button Properties
Create a Listview button in TPDesign5 and configure the display characteristics for the default and selected states.
Although not currently being rendered correctly in the screenshot below, this Listview has two lines of text and an image icon on the left for each Listview entry.
1.
In TPDesign5 (v1.0.2 or greater), use the Button Draw Tool to draw a new button.
2.
In the General tab of the Properties window, select Listview as the Type
FIG. 162 TPDesign5 - Listview button
3.
Use the TPD5 Properties window to set General , Programming , States and Events properties to configure the list items and the display characteristics for the Default and Selected states, as well as provide the Listview button with an Address code assignment. Note that Listview buttons use standard button properties, as well as several new properties that are specific to
Listview buttons: a. In the General
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 182
Type = Listview
Appendix B: Using NetLinx to Define a Data Source (Listview Buttons)
Listview-specific properties
FIG. 163 TPDesign5 - General Properties for Listview buttons
General button properties that are specific to Listview buttons include:
Listview Buttons - General Properties
List View Components This property controls which components ( Primary Text, Secondary Text and Image ) will be displayed on the selected Listview button.
With a Listview button selected in the Design View, click the browse (...) button on the Listview Components
(General) property to open the Edit Listview Components dialog. Use this dialog to specify which components
(Primary Text, Secondary Text and Image) will be displayed on the selected Listview button.
If only Primary Text is selected in the Edit Listview Components dialog (the default setting for new Listview buttons), each list item is represented with a single line of text using center-middle justification and the font face and size specified by the Text Color , Font and Font Size (State) properties (as well as Text Effect and Text
Effect Color if desired).
• The List View Components (General) Property will indicate single-line text .
If Primary Text and Secondary Text are selected, each list item is represented with a two lines of text.
• The two lines of text are stacked vertically, with each line centered horizontally.
• The font face and size are specified by the Secondary Font and Secondary Font Size (State) properties. The text is rendered within a two-pixel margin of the button boundary.
• Note that the Secondary Text option is only enabled if Primary Text is selected.
• Secondary Text uses the same Text Color settings as the Primary Text.
• The List View Components (General) Property will indicate two-line text .
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 183
Appendix B: Using NetLinx to Define a Data Source (Listview Buttons)
Listview Buttons - General Properties (Cont.)
List View Components
(Cont.)
If Primary Text , Secondary Text and Image are selected, each list item is represented with two lines of text and an image on the left side.
• The image is left-justified within a six-pixel margin of the top, bottom, and left item boundaries, and is scaled-to-fit within a square region.
• The two lines of text are stacked vertically and centered horizontally in the remaining item region. The top line (Primary Text) is rendered using the font face and size specified by the Font and Font Size (State) properties. The bottom line (Secondary Text) is rendered using the font face and size specified by the
Secondary Font and Secondary Font Size (State) properties. The text is rendered within a two-pixel margin of the button boundary.
• The List View Components (General) Property will indicate two-line text w/ Image .
If only Image is selected in the Edit Listview Components dialog, each list item is represented with a single image centered horizontally within the item region, within a six-pixel margin of the item region.
• The List View Components (General) Property will indicate image only .
If Primary Text and Image are selected in the Edit Listview Components dialog, each list item is represented with a single line of text and an image on the left side.
Item Height
List View Columns
List View Item Layout
Primary Partition (%)
Secondary Partition
(%)
• The image is left-justified within a six-pixel margin of the top, bottom, and left item boundaries, and is scaled-to-fit within a square region.
• The text is center-middle justified in the remaining portion of the item region within a two-pixel margin, using the font and font size specified by the Font and Font Size (States) properties.
• The List View Components (General) Property will indicate single-line text w/ Image .
This property controls the height for the list view items (in pixels).
This property controls the number of columns to display. By default, this value is set to 1. This property provides the ability to present a "grid view" on the Listview button, if desired.
This property controls the layout of the components ( Primary Text, Secondary Text and Image ) specified to display on the list view items in the selected Listview button. Listview components are selected via the List View
Components (General) property.
Click in this field to select from a drop-down of layout options for list items (horizontal - image left, horizontal - image right and vertical - image top).
This property sets the position of the separation between the Image and the Primary/Secondary Text components.
If the List View Item Layout property is set to is set to horizontal - image left (the default setting), the
Secondary Partition (%) sets the position of the separation between the Primary Text and the Image as a percentage of cell height (allowed range = 5%-95%).
• If the List View Item Layout property is set to is set to horizontal - image right, the Secondary Partition (%) sets the position of the separation between the Primary Text and the Image as a percentage of cell height
(allowed range = 5%-95%):
• If the List View Item Layout property is set to vertical- image top, the Secondary Partition represents the area used by the Image. In this case, Secondary Partition (%) sets the position of the separation between the Image and the Primary Text as a percentage of cell height (allowed range = 5%-95%).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 184
Appendix B: Using NetLinx to Define a Data Source (Listview Buttons)
Listview Buttons - General Properties (Cont.)
Filter Enabled
Filter Height
Alphabet Scrollbar
Dynamic Data Source
Use this property to enable/disable the filter (Search) feature on the selected Listview button. By default, this property is set to no (disabled).
To enable this feature, select yes from the drop-down menu. If enabled, a search window will be rendered at the top of the Listview button, with a height specified by the Filter Height property. The remaining area of the
Listview button will be available for the display of list items:
Use this property to specify the height of the filter entry box for a Listview button (in pixels).
• Note that this property is available only if Filter Enabled is set to Yes .
• The minimum allowed value (and the default setting) is 24 pixels.
This property enables/disables the alphabet scrollbar feature for Listview buttons.
This property specifies the data source (CSV or XML) to use as the source for content that will be displayed on the selected Listview button.
b. In the Programming tab, assign a unique Address Port and Address Code to the selected Listview button:
Listview Buttons - Programming Properties
Address Code Select or enter the address code sent to the master on the specified Address Port.
The options available to the Address Code property depend on the Address Port selection:
• If 1 is selected as the Address Port, then the options for Address Code are None and Auto-Assign.
Select None to leave the Address Code unspecified.
Select Auto-Assign to automatically assign the next available Address Code to the selected TPD5 element.
• If 0-Setup Port is selected as the Address Port, then the options for Address Code are Advanced Codes or
Basic Codes. By default, the Basic Address Codes are displayed:
Click on Date Display to select from a list of date display formats.
Click on Time Display to select from a list of time display formats.
Click Advanced Codes to view the Advanced Channel Code options:
Click on None to leave the Address Code unspecified.
Click on Panel Setup to select Connection Status. This option will display the panel's current connection status on the selected element.
Address Port Select or enter the port to which the selected element's Address Code will be associated.
The options are "1" (the default setting) and "0-setup port":
• If 1 is selected as the Address Port, then the options for the Address Code property are None and Auto-
Assign.
• If 0-Setup Port is selected as the Address Port, then the options for Address Code are Advanced Codes or
Basic Codes. By default, the Basic Address Codes are displayed.
Note that Listview buttons do not use Channel Port and Channel Code assignments.
The combination of Address Port and Address Code must be unique.
See Address Codes (Basic and Advanced) in the TPD5 online help for details.
c. d.
In the States tab, set (font) properties to specify font display characteristics for the Default and Selected states for the selected Listview button. States properties that are specific to Listview buttons include:
Secondary Font
Secondary Font Size
In the Events tab, set event properties for the selected Listview button. Listview button support three Events properties that are specific to Listview buttons. However, these Events support the same actions as existing events:
Item Selected
Scrollbar Begin
Scrollbar End
NOTE: Refer to the TPDesign5 online help for descriptions of all button properties.
2) Create the Data Source
Follow the example NetLinx code (below) to create a data source in NetLinx and publish the data source to the NetLinx Master’s internal web server.
The " Data_PublishFeed() " function (see NetLinx.axi
) will return a URL for the published data.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 185
Appendix B: Using NetLinx to Define a Data Source (Listview Buttons)
NetLinx Usage Example - ASCII
PROGRAM_NAME=' Listview Example '
DEFINE_DEVICE dvTP = 10001:1:0
DEFINE_CONSTANT
// Listview button address
INTEGER btnListview = 11
DEFINE_VARIABLE
CHAR publishedURL[DATA_MAX_VALUE_LENGTH]
CHAR recordsetID[DATA_MAX_ID_LENGTH]
DEFINE_FUNCTION CreateDataFeed()
{
STACK_VAR DATA_FEED datafeed
STACK_VAR DATA_RECORD record
// --------------------------------------------------
// CREATE A NEW DATA FEED
// --------------------------------------------------
datafeed.name = 'phonelist'
datafeed.description = 'Employees'
datafeed.source = 'netlinx Listview Example code'
DATA_CREATE_FEED(datafeed)
// A recordset id is required for adding records to the feed
recordsetID = 'phonelist'
// --------------------------------------------------
// DEFINE AND POPULATE THE DATA FIELDS
// This example will have 10 names in a phone list
// --------------------------------------------------
// Records can have metadata fields and content fields. In this
// example we won't use any metadata
SET_LENGTH_ARRAY(record.metadata, 0)
// We will have 3 content fields per record: photo, name and phone number
SET_LENGTH_ARRAY(record.content, 3)
// Initialize the field attributes that will be the same for every record
// the first field in a record will be the image
record.content[1].id = 'photo' ;
record.content[1].type = DATA_TYPE_IMAGE;
record.content[1].format = DATA_FORMAT_URL;
// The label can be something different from the id but in our case we'll
// keep them the same
record.content[1].label = 'photo' ;
// The second field in a record will be the name
record.content[2].id = 'name' ;
record.content[2].type = DATA_TYPE_STRING;
record.content[2].format = '' ;
record.content[2].label = 'name' ;
// The third field will be the phone number
record.content[3].id = 'number' ;
record.content[3].type = DATA_TYPE_STRING;
record.content[3].format = DATA_FORMAT_PHONE;
record.content[3].label = 'number' ;
// The next step is to put in the actual values for the 3 fields
// Do this for the first record
record.content[1].value = 'http://192.168.222.333/ftp/listview/hunter.jpg'
record.content[2].value = 'Hunter Pence'
record.content[3].value = '888-555-1111'
// Add the record to the feed
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 186
Appendix B: Using NetLinx to Define a Data Source (Listview Buttons)
// The same record can be reused for the rest of the list
// Just change the relevant values and add the record to the feed
record.content[1].value = 'http://192.168.222.333/ftp/listview/pablo.jpg'
record.content[2].value = 'Pablo Sandoval'
record.content[3].value = '888-555-2222'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/buster.jpg'
record.content[2].value = 'Buster Posey'
record.content[3].value = '888-555-3333'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/angel.jpg'
record.content[2].value = 'Angel Pagan'
record.content[3].value = '888-555-4444'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/jeremy.jpg'
record.content[2].value = 'Jeremy Affeldt'
record.content[3].value = '888-555-5555'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/madison.jpg'
record.content[2].value = 'Madison Bumgarner'
record.content[3].value = '888-555-6666'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/timh.jpg'
record.content[2].value = 'Tim Hudson'
record.content[3].value = '4888-555-7777
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/timl.jpg'
record.content[2].value = 'Tim Lincecum'
record.content[3].value = '888-555-8888'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/javier.jpg'
record.content[2].value = 'Javier Lopez'
record.content[3].value = '888-555-9999'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/jake.jpg'
record.content[2].value = 'Jake Peavy'
record.content[3].value = '888-555-1010'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/sergio.jpg'
record.content[2].value = 'Sergio Romo'
record.content[3].value = '888-555-1020'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/ryan.jpg'
record.content[2].value = 'Ryan Vogelsong'
record.content[3].value = '888-555-1030'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/brandon.jpg'
record.content[2].value = 'Brandon Belt'
record.content[3].value = '888-555-1040'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/andrew.jpg'
record.content[2].value = 'Andrew Susac'
record.content[3].value = '888-555-1050'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/gregor.jpg'
record.content[2].value = 'Gregor Blanco'
record.content[3].value = '888-555-1060'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
record.content[1].value = 'http://192.168.222.333/ftp/listview/michael.jpg'
record.content[2].value = 'Michael Morse'
record.content[3].value = '888-555-1070'
DATA_ADD_RECORD(datafeed.name, recordsetID, record)
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 187
Appendix B: Using NetLinx to Define a Data Source (Listview Buttons)
// The final step is to publish the feed
publishedURL = DATA_PUBLISH_FEED(datafeed.name)
}
DEFINE_START
CreateDataFeed()
DEFINE_EVENT
DATA_EVENT[dvTP]
{
ONLINE:
{
// Set the URL for the data source for the listviewer in the panel
SEND_COMMAND dvTP, "'^LVD-',ITOA(btnListview),',',publishedURL"
// Map the fields in the listviewer to the columns
SEND_COMMAND dvTP, "'^LVM-',ITOA(btnListview),',i1=${photo}|t1=${name}|t2=${number}'"
// Sort by name
SEND_COMMAND dvTP, "'^LVS-',ITOA(btnListview),',${name};a'"
// Command the listview to load the data from the master
SEND_COMMAND dvTP, "'^LVR-',ITOA(btnListview)"
}
}
// The custom event that is raised whenever a listview item is selected on the panel
CUSTOM_EVENT[dvTP,btnListview,LISTVIEW_ON_ROW_SELECT_EVENT]
{
SLONG payloadId
SLONG payloadType
CHAR fields[2][16]
CHAR name[DATA_MAX_VALUE_LENGTH]
CHAR number[DATA_MAX_VALUE_LENGTH]
DATA_RECORD record
// Get the data access ID from the custom event
payloadId = custom.value1
// Get the data type from the custom event
payloadType = custom.value2
if (payloadId > 0 && payloadType == DATA_STRUCTURE_DATARECORD)
{
// Specify which fields we want to retrieve from the payload
fields[1] = 'name'
fields[2] = 'number'
// Populate a record with the requested fields from the event
if (DATA_GET_EVENT_RECORD(dvTP, payloadId, fields, record) > 0)
{
// All is well so far so retrieve the values that we are
// interested in from the selection that the user made on
// the panel.
name = record.content[1].value
number = record.content[2].value
// Put the name and number that was selected on a popup and
// show the popup
SEND_COMMAND dvTP, "'^TXT-50,0,',name"
SEND_COMMAND dvTP, "'^TXT-51,0,',number"
SEND_COMMAND dvTP, "'^PPN-Calling'"
}
}
}
(***********************************************************)
(* THE ACTUAL PROGRAM GOES BELOW *)
(***********************************************************)
DEFINE_PROGRAM
(***********************************************************)
(* END OF PROGRAM *)
(* DO NOT PUT ANY CODE BELOW THIS COMMENT *)
(***********************************************************)
3) Configure the Response to a User Selection
Follow the CUSTOM_EVENT example at the end of the NetLinx Usage Example - ASCII ( above) to retrieve the phone number that was selected by the user.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 188
Appendix C: Text Formatting
Appendix C: Text Formatting
Text Formatting Codes for Bargraphs
Text formatting codes for bargraphs provide a mechanism to allow a portion of a bargraphs text to be dynamically provided information about the current status of the level (multistate and traditional). These codes are entered into the text field along with any other text.
The following is a code list used for bargraphs:
Bargraph Text Code Inputs
Code
$P
$V
$L
Bargraph
Display the current percentage of the bargraph (derived from the Adjusted Level Value as it falls between the
Range Values)
Raw Level Value
Range Low Value
$H
$S
$A
$R
$$
Range High Value
N/A
Adjusted Level Value (Range Low Value subtracted from the Raw Level Value)
Low Range subtracted from the High Range
Dollar sign
Multi-State Bargraph
Display the current percentage of the bargraph (derived from the Adjusted Level Value as it falls between the Range Values)
Raw Level Value
Range Low Value
Range High Value
Current State
Adjusted Level Value (Range Low Value subtracted from the
Raw Level Value)
Low Range subtracted from the High Range
Dollar sign
By changing the text on a button (via a VT command), you can modify the codes on a button. When one of the Text Formatting
Codes is encountered by the firmware, it is replaced with the correct value. These values are derived from the following operations:
Formatting Code Operations
$H
$S
$A
$R
Code
$P
$V
$L
Operation
(Current Value - Range Low Value / Range High Value - Range Low Value) x 100
Current Level Value
Range Low Value
Range High Value
Current State (if regular bargraph then resolves to nothing)
Current Value - Range Low Value
Range High Value - Range Low Value
Given a current raw level value of 532, a range low value of 500, and a high range value of 600, the following text formatting codes would yield the following strings as shown in the table below:
Example
Format
$P%
$A out of $R
$A of 0 - $R
$V of $L - $H
Display
32%
32 out of 100
32 of 0 - 100
532 of 500 - 600
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 189
Appendix C: Text Formatting
Text Area Input Masking
Text Area Input Masking may be used to limit the allowed/correct characters that are entered into a text area. For example, in working with a zip code, a user could limit the entry to a max length of only 5 characters; with input masking, this limit could be changed to 5 mandatory numerical digits and 4 optional numerical digits. A possible use for this feature is to enter information into form fields. The purpose of this feature is to:
• Force the use of correct type of characters (i.e. numbers vs. characters)
• Limit the number of characters in a text area
• Suggest proper format with fixed characters
• Right to Left
• Required or Optional
• Change/Force a Case
• Create multiple logical fields
• Specify range of characters/number for each field
With this feature, it is not necessary to:
• Limit the user to a choice of selections
• Handle complex input tasks such as names, days of the week, or month by name
• Perform complex validation such as Subnet Mask validation
Input mask character types
These character types define what information is allowed to be entered in any specific instance. The following table lists what characters in an input mask will define what characters are allowed in any given position.
Character Types
Character Masking Rule
0 Digit (0 to 9, entry required, plus [+] and minus [-] signs not allowed)
9 Digit or space (entry not required, plus and minus signs not allowed) a
&
C
?
A
#
L
Digit or space (entry not required; plus and minus signs allowed)
Letter (A to Z, entry required)
Letter (A to Z, entry optional)
Letter or digit (entry required)
Letter or digit (entry optional)
Any character or a space (entry required)
Any character or a space (entry optional)
NOTE: The number of the above characters used determines the length of the input masking box. Example: 0000 requires an entry, requires digits to be used, and allows only 4 characters to be entered/used.
Refer to the following SEND_COMMANDs for more detailed information:
•
•
^BIM
^BMF
- Sets the input mask for the specified addresses - see page 112.
subcommand
%MK
- sets the input mask of a text area - see page 114.
Input Mask Ranges
These ranges allow a user to specify the minimum and maximum numeric value for a field. Only one range is allowed per field. Using a range implies a numeric entry ONLY.
Input Mask Ranges
Character Meaning
]
[
|
Start range
End range
Range Separator
An example from the above table:
[0|255] This allows a user to enter a value from 0 to 255.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 190
Appendix C: Text Formatting
Input Mask Operations
Input Mask Operators change the behavior of the field in the following way:
Input Mask Operators
Character Meaning
< Forces all characters to be converted to lowercase
> Forces all characters to be converted to uppercase
Input Mask Literals
To define a literal character, enter any character, other than those shown in the above table (including spaces, and symbols) . A back-slash ('\') causes the character that follows it to be displayed as the literal character. For example, \A is displayed just as the letter A . To define one of the following characters as a literal character, precede that character with a back-slash. Text entry operation using Input Masks.
A keyboard entry using normal text entry is straightforward. However, once an input mask is applied, the behavior of the keyboard needs to change to accommodate the input mask's requirement. When working with masks, any literal characters in the mask will be "skipped" by any cursor movement, including cursor, backspace, and delete keys.
When operating with a mask, the mask should be displayed with placeholders. The "-" character should display where you should enter a character. The arrow keys will move between the "-" characters and allow you to replace them. The text entry code operates as if it is in the overwrite mode. If the cursor is positioned on a character already entered and you type in a new (and valid) character, the new character replaces the old character. There is no shifting of characters.
When working with ranges specified by the [] mask, the keyboard allows you to enter a number between the values listed in the ranges. If a user enters a value that is larger than the maximum, the maximum number of right-most characters is used to create a new, acceptable value.
Example 1 : If you type "125" into a field accepting 0-100, then the values displayed will be "1", "12", "25".
Example 2 : If the max for the field was 20, then the values displayed will be "1", "12", "5".
When data overflows from a numerical field, the overflow value is added to the previous field on the chain if the overflow character was specified. In the above example, if the overflow flag was set, the first example will place the "1" into the previous logical field and the second example will place "12" in the previous logical field. If the overflow field already contains a value, the new value will be inserted to the right of the current characters and the overflow field will be evaluated. Overflow continues to work until a field with no overflow value is set or no more fields remain (i.e. reached first field).
If a character is typed and that character appears in the Next Field list, the keyboard should move the focus to the next field. For example, when entering time, a ":" is used as a next field character. If you enter "1:2", the 1 is entered in the current field (hours) and then the focus is moved to the next field and 2 is entered in that field.
When entering time in a 12-hour format, entry of AM and PM is required. Instead of adding AM/PM to the input mask specification, the AM/PM should be handled within the NetLinx code. This allows a programmer to show/hide and provide discrete feedback for
AM and PM.
Input Mask Output Examples
The following are some common input masking examples:
Output Examples
Common Name
IP Address Quad
Hour
Minute/Second
Frames
Phone Numbers
Zip Code
Input Mask
[0|255]{.}
[1|12]{:}
[0|59]{:}
[0|29]{:}
(999) 000-0000
00000-9999
Input
Any value from 0 to 255
Any value from 1 to 12
Any value from 0 to 59
Any value from 0 to 29
(555) 555-5555
75082-4567
URL Resources
A URL can be broken into several parts. For example, with the URL http://www.amx.com/company-info-home.asp
, this URL indicates that the protocol in use is http (HyperText Transport Protocol) and that the information resides on a host machine named www.amx.com
. The image on that host machine is given an assignment ( by the program ) name of company-info-home.asp (Active
Server Page) .
The exact meaning of this name on the host machine is both protocol dependent and host dependent. The information normally resides in a file, but it could be generated dynamically. This component of the URL is called the file component, even though the information is not necessarily in a file.
A URL can optionally specify a port, which is the port number to which the TCP/IP connection is made on the remote host machine.
If the port is not specified, the default port for the protocol is used instead. For example, the default port for http is 80 . An alternative port could be specified as: http://www.amx.com:8080/company-info-home.asp
.
NOTE: Any legal HTTP syntax can be used.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 191
Appendix C: Text Formatting
Special Escape Sequences
The system has only a limited knowledge of URL formats, as it transparently passes the URL information onto the server for translation. A user can then pass any parameters to the server side programs such as CGI scripts or active server pages. However; the system will parse the URL looking for special escape codes. When it finds an escape code, it replaces that code with a particular piece of panel, button, or state information.
For example, "http://www.amx.com/img.asp?device=$DV" would become http://www.amx.com/img.asp?device=10001 .
Other used escape sequences include:
Escape Sequences
$AC
$AP
$CC
$CP
$BX
$BY
$BN
$ST
$LC
$LP
Sequence
$DV
$SY
$IP
$HN
$MC
$PX
$PY
Panel Information
Device Number
System Number
IP Address
Host Name
Mac Address
X Resolution of current panel mode/file
Y Resolution of current panel mode/file
X Resolution of current button
Y Resolution of current button
Name of button
Current state
Address Code
Address Port
Channel Code
Channel Port
Level Code
Level Port
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 192
Appendix D: Bargraph Functions
Appendix D: Bargraph Functions
Overview
For drag operations on Bargraph and Multi-State Bargraph buttons, each movement increments based on the drag increment field.
For centering, the bargraph/multistate bargraph will return to the middle - either the 50% mark for bargraphs, or the median state number, once the touch point is released.
Setup Codes
Bargraph Functions - Setup Codes
Type
Channel
Code Description
2 Panel Setup:Brightness Up
Channel
Channel
Channel
Channel
3 Panel Setup: Brightness Down
6 Panel Setup: Master Volume Up
7 Panel Setup: Master Volume Down
8 Panel Setup: Master Volume Mute
Channel 158 Panel Setup: Mic Volume Mute
Channel 171 Panel Setup:Call Volume Up
Channel 172 Panel Setup: Call Volume Down
Channel 1403 Panel Setup:Notification Alarm Volume Mute
Channel 1404 Panel Setup:Notification Volume Up
Channel 1405 Panel Setup:Notification Volume Down
Channel 1407 Panel Setup:Alarm Volume Up
Channel 1408 Panel Setup:Alarm Volume Down
Address 33 Panel Setup:Brightness
Address 35 Panel Setup:Master Volume
Address 144 Time Display: AM|PM
Address 46 Panel Setup:Call Volume
Address 450 Panel Setup:Notification Volume
Address 451 Panel Setup:Alarm Volume
Level
Level
1
3
Panel Setup:Brightness
Panel Setup:Master Volume
Level
Level
Level
9 Panel Setup:Call Volume
450 Panel Setup:Notification Volume
451 Panel Setup:Alarm Volume
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 193
Appendix E: Video Streaming
Appendix E: Video Streaming
Optimizing Motion JPEG Video Presentation and Speed
In some cases, multiple Motion JPEG streams may slow presentation of individual screen popups, or prevent all of the streams from showing at the same time. This may happen even though the Panel Preview in TPDesign 5 may show no issues. To minimize this and assure a smooth and non-sluggish stream, try these options:
Limit the number of simultaneous Motion JPEG streams to eight or fewer streams at a time.
Remove any unnecessary buttons associated with the Motion JPEG streams.
Make sure that the Refresh rate on a Motion JPEG is set to 0.
Make sure to hide the preview popup before displaying the full image.
If possible, uncheck the “Scale to Fit” option, as scaling is very resource-intensive.
Dial down the frame rate of the server. The frame rate of a Motion JPEG is determined by the server.
When you go from a page with multiple previews to a page with a single full screen video, it is best to do a page flip rather than popup attach, or hide the preview windows first. Otherwise, the preview windows will continue to decode (taxing the system), even though they may be completely or partially obstructed by the popup.
Verify that the full-screen image is set for acceleration by checking the “Dynamo” box in Resource Manager.
Motion JPEG Support for Modero X Series G5 Panels
Baseline mode:
Encoding:
ISO 10918-1
ISO-10918-5 (JFIF)
Maximum Resolution: 720p
Recommended resolution: 720x480-NTSC or 720x576-PAL (or less).
If the video is defined in the Resource Manager as opposed to video fill, consideration must be made for the video being decoded by the Modero X Series panel, which cannot decode 720p.
Maximum Frame Rate:
Latency:
Up to 30fps
From 1-3 seconds, depending on multiple factors including button size, resolution and network performance.
Streaming a Video File Saved on the Panel via Custom URL Scheme
To use a custom URL scheme and File Transfer (in NetLinx Studio) to play a video stored in the G5 touch panel’s internal storage:
1.
In NetLinx Studio 4, select Tools -> File Transfer to open the File Transfer dialog - Send
FIG. 164 NetLinx Studio 4 - File Transfer dialog
2.
Click Add to open the Select Files for File Transfer dialog, open the Individual Files tab and select Send Non-System File
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 194
Appendix E: Video Streaming
FIG. 165 NetLinx Studio 4 - Select Files for File Transfer dialog (Individual Files tab)
3.
Click Add to select the video file you want to use: Select the video file in the Open dialog and click OK to invoke the Enter Device
Mapping Information
FIG. 166 NetLinx Studio 4 - Enter Device Mapping Information dialog
4.
Enter device mapping information (D:P:S) for the target G5 panel Leave the Master Directory field blank.
5.
Click OK to save changes and close the Enter Device Mapping Information dialog.
6.
Click OK to close the Select File For File Transfer dialog.
7.
Click Send in the File Transfer dialog to transfer the file (this may take time for large video files).
8.
In TPDesign5, select the page/button state you want to play the video file.
9.
In the desired state tab, set the Video Fill property to streaming video
(FIG. 167). Note that this selection enables the
Streaming Source property.
FIG. 167 TPDesign5 - Video Fill (State) property
10. For the Streaming Source property, enter the filename of the video file with amxdir:/// as the prefix. For example, if the video filename is "test-video.mp4" then enter the Streaming Source as " amxdir:///test-video.mp4
FIG. 168 TPDesign5 - Streaming Source (State) property
NOTE: There are three slashes after amxdir:, not two as in a standard URL. If there aren't three slashes the video file won't be found.
11. Load the TP5 file on the panel and the desired state should continually play the video.
If you desire to change the video using the ^SDM command to another that you have transfered, use the same URL scheme as the prefix ( amxdir:/// ).
Any file that is transfered to the amxdir:/// directory is not cleared by a panel file transfer or "Remove User Pages". The only way to transfer is to do a Factory Data Reset, or to upload an empty file with the same filename.
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 195
Appendix E: Video Streaming
To get around this, you can specify a file to be amxdir:///AMXPanel/images/filename instead.
To do this using NetLinx Studio File Transfer, set the "Master Directory" to \AMXPanel\images\ in the device mapping. This will put the file in the panel file images directory. A TP5 file transfer will not remove the file, but a "Remove User Pages" will. The Streaming
Source value in the TP5 file would have to correspond to the same path.
NOTE:
See page 132 for details on the ^SDM Button State Streaming Digital Media command.
Transcoding Guidelines
For certain H.264 video and audio streaming , you may observe a drift between audio and video the longer the content is streamed.
This drift can be more pronounced when streaming from a non- MXA-MPL source such as a Vision 2 steaming server. If the panel detects excessive drift, it will attempt to restart the stream decode. During the restart, the audio will be temporarily interrupted and the video will be frozen on the last frame until the restart is complete (typically a couple of seconds). To reduce the drift issue for
Vision 2 H264 steaming, video transcoding tools (such as HandBrake or FFMPEG) are available to convert H.264 video into lower bitrates, reduced resolution and/or lower H.264 profiles. For example you can try the H.264, 2mbps bit rate, 480p resolution,
Baseline profile. If this does not work, try transcoding the stream into MPEG2 video, which is less susceptible to A/V drift.
NOTE: Third-party encoders and digital television devices have not been tested with Modero X Series G5 touch panels, and are not supported by AMX.
The table below lists the typical synchronization and latency times for each supported video and audio stream:
Video Performance
Device Typical
A/V Sync
(offset/ hr)
Typical
A/V Sync
Restart
Rate
Expected
Latency -
Typical
Expected
Latency -
Max
Notes:
MXA-MPL
H.264
<100ms ~ every
3hrs
750ms
(Video)
1s (Audio +
Video
2s or more, depending on network
MPEG2
H.264
MPEG2
N/A N/A
<100ms ~ every
1-2hrs
<100ms ~ every
1-2hrs
N/A
1.5s
1.5s
N/A
3s or more, depending on network
3s or more, depending on network
Recommend maintaining aspect ratio of source and following usage guidelines regarding window/button placement.
Network congestion can cause video glitches. AMX recommends the Multi-
Preview Live and Modero X touch panel be installed behind a smart
Ethernet switch to filter multicast packets reaching the panel and consuming panel resources.
N/A
Network congestion can cause video glitches. AMX recommends the
Modero X touch panel be installed behind a smart Ethernet switch to filter unintended multicast packets reaching the panel and consuming panel resources.
Recommend maintaining aspect ratio of source and following usage guidelines regarding window/button placement.
• AAC <= 192Kbps @ 48KHz
• H.264 video 720p max (D1 for best results),
< 30fps max and a 4Mbps bitrate
• UDP Transport protocol only (RTP not supported)
• Multicast and/or unicast addresses
• SAP disabled
May require transcoding to H.264 baseline profile and reducing resolution/ frame rate/bit rate per recommendations above.
Recommend transcoding source material to MPEG2 if Audio/Video sync issues still occur after following above guidelines.
Network congestion can cause video glitches. We recommend the panel be installed behind a smart Ethernet switch to filter unintended multicast packets reaching the panel and consuming panel resources.
Recommend maintaining aspect ratio of source and following usage guidelines regarding window/button placement. Best results are obtained with standard definition (NTSC or PAL) sources.
Minor audio/video irregularities may be noticed depending on network performance, video source content, and window size. Note: Video frame rate can be affected by network performance.
MPEG-2 video streaming Settings:
• MP2/MP3 audio <= 192Kbps @ 48KHz
• MPEG2 video 720p max < 30fps max bitrate of 8Mbps
• UDP Transport protocol only (RTP not supported)
• Multicast and/or unicast addresses
• SAP disabled
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 196
Appendix E: Video Streaming
Video Performance (Cont.)
Device Typical
A/V Sync
(offset/ hr)
3rd Party Solutions
H.264
N/A
Typical
A/V Sync
Restart
Rate
Expected
Latency -
Typical
Expected
Latency -
Max
Notes:
N/A N/A N/A Third-party encoders and digital television devices have not been tested with Modero X Series touch panels, and are not supported by AMX.
Network congestion can cause video glitches. We recommend the panel be installed behind a smart Ethernet switch to filter unintended multicast packets reaching the panel and consuming panel resources.
We recommend maintaining aspect ratio of source and following usage guidelines regarding window/button placement.
MPEG2 N/A N/A N/A N/A Third-party encoders and digital television devices have not been tested with Modero X Series touch panels, and are not supported by AMX.
Network congestion can cause video glitches. We recommend the panel be installed behind a smart Ethernet switch to filter unintended multicast packets reaching the panel and consuming panel resources.
We recommend maintaining aspect ratio of source and following usage guidelines regarding window/button placement.
NMX-ENC H.264 Encoder - Encoder Settings for G5 Panels
The Modero X Series® G5 line of touch panels can receive video streams from the NMX-ENC H.264 Encoder (FG3201-01), provided that the Encoding settings on the NMX-ENC are configured correctly. Encoding settings for the NMX-ENC are set via the on-board
WebConsole interface.
NOTE: Due to resource constraints, the number of playing video streams on a G5 panel is limited to two (720dpi, 30fps). If two or more video streams are requested to play, only the latest two streams with different url will be started.
The WebConsole is accessed via a web browser on a PC that has network access to the encoder. You can access the WebConsole by entering the IP address of the encoder into a web browser. (see the NMX-ENC H.264 Encoder Instruction Manual for details).
The NMX-ENC H.264 Encoder should be configured such that:
Maximum resolution for video windows: 720dpi
Maximum frame rate for video windows: 30fps
To view / set Encoding options, open the NMX-ENC WebConsole to the Encoding tab.
Note that by default, Frame Decimation is set to " None
FIG. 169 NMX-ENC WebConsole - Encoding tab
To use the NMX-ENC with X Series G5 touch panels, change the Frame Decimation setting from " None " (the default setting) to
" 1/2" (via the drop-down menu).
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 197
Appendix F: DragDrop.axi
Appendix F: DragDrop.axi
Overview
NOTE: G5 Panels and TPDesign5 support "drag-and-drop" functionality for General and Multi-State General buttons. This allows the end-user to initiate a drag on a button with a "long press", then drag and release (or "drop") the button onto a drop target. Refer to the TPDesign5 Instruction Manual and online help for information on adding drag-and-drop functionality to your TPDesign5 project.
See page 110 for a description of the
^BDC Send Command (Button Drag and Drop Custom Event Command).
The NetLinx .AXI
file below provides routines to parse the drag and drop info strings:
PROGRAM_NAME ='DragDrop'
(***********************************************************)
(* DEVICE NUMBER DEFINITIONS GO BELOW *)
(***********************************************************)
DEFINE_DEVICE
(***********************************************************)
(* CONSTANT DEFINITIONS GO BELOW *)
(***********************************************************)
DEFINE_CONSTANT
#IF_NOT_DEFINED __DRAG_DROP_MAX_TARGETS__
#DEFINE __DRAG_DROP_MAX_TARGETS__ '__DRAG_DROP_MAX_TARGETS=100'
INTEGER __DRAG_DROP_MAX_TARGETS = 100;
#END_IF
#IF_NOT_DEFINED __DRAG_DROP_NUM_PANELS__
#DEFINE __DRAG_DROP_NUM_PANELS__ '__DRAG_DROP_NUM_PANELS=1'
INTEGER __DRAG_DROP_NUM_PANELS = 1;
#END_IF
(***********************************************************)
(* DATA TYPE DEFINITIONS GO BELOW *)
(***********************************************************)
DEFINE_TYPE
STRUCTURE __DRAG_DROP_sDragObject
{
INTEGER chanPort ;
INTEGER chan ;
INTEGER addrPort ;
INTEGER addr ; char groupName [100]; char buttonName [100];
}
STRUCTURE __DRAG_DROP_sDropTargetObject
{
INTEGER valid ;
INTEGER chanPort ;
INTEGER chan ;
INTEGER addrPort ;
INTEGER addr ; char buttonName [100];
}
(***********************************************************)
(* VARIABLE DEFINITIONS GO BELOW *)
(***********************************************************)
DEFINE_VARIABLE
VOLATILE __DRAG_DROP_sDragObject __DRAG_DROP_current_drag [ __DRAG_DROP_NUM_PANELS ];
VOLATILE __DRAG_DROP_sDropTargetObject __DRAG_DROP_current_targets [ __DRAG_DROP_NUM_PANELS ]
[ __DRAG_DROP_MAX_TARGETS ];
VOLATILE INTEGER __DRAG_DROP_target_count [ __DRAG_DROP_NUM_PANELS ];
VOLATILE INTEGER __DRAG_DROP_panel_devices [ __DRAG_DROP_NUM_PANELS ]
(***********************************************************)
(* SUBROUTINE/FUNCTION DEFINITIONS GO BELOW *)
(***********************************************************)
(* EXAMPLE: DEFINE_FUNCTION <RETURN_TYPE> <NAME> (<PARAMETERS>) *)
(* EXAMPLE: DEFINE_CALL '<NAME>' (<PARAMETERS>) *)
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 198
DEFINE_FUNCTION __DRAG_DROP_SET_PANELS ( INTEGER panels [])
{ if ( LENGTH_ARRAY ( panels ) <= __DRAG_DROP_NUM_PANELS )
{
__DRAG_DROP_panel_devices = panels ;
} else
{
STACK_VAR INTEGER count; for ( count = 1 ; count <= __DRAG_DROP_NUM_PANELS ; count++ )
{
__DRAG_DROP_panel_devices [count] = panels [ count ];
}
SET_LENGTH_ARRAY ( __DRAG_DROP_panel_devices , count );
}
}
DEFINE_FUNCTION __DRAG_DROP_CLEAR_DATA ( INTEGER panel )
{
STACK_VAR INTEGER count ;
__DRAG_DROP_current_drag [ panel ].
chanPort = 0;
__DRAG_DROP_current_drag [ panel ].
chan = 0;
__DRAG_DROP_current_drag [ panel ].
addrPort = 0;
__DRAG_DROP_current_drag [ panel ].
addr = 0;
__DRAG_DROP_current_drag [ panel ].
buttonName = '' ;
__DRAG_DROP_current_drag [ panel ].
groupName = '' ; count = LENGTH_ARRAY (_ _DRAG_DROP_current_targets [ panel ]); if ( count > 0)
{
STACK_VAR INTEGER x;
for(x = 1; x <= count; x++)
{
__DRAG_DROP_current_targets [ panel ][ x ].
chanPort = 0;
__DRAG_DROP_current_targets [ panel ][ x ].
chan = 0;
__DRAG_DROP_current_targets [ panel ][ x ].
addrPort = 0;
__DRAG_DROP_current_targets [ panel ][ x ].
addr = 0;
__DRAG_DROP_current_targets [ panel ][ x ].
buttonName = '' ;
__DRAG_DROP_current_targets [ panel ][ x ].
valid = 0;
}
}
__DRAG_DROP_target_count [ panel ] = 0;
}
DEFINE_FUNCTION INTEGER __DRAG_DROP_PARSE_PORT_VALUE (
CHAR line [],
INTEGER start ,
INTEGER port ,
INTEGER value )
{
STACK_VAR INTEGER x , run, state;
STACK_VAR char ch ; x = start ;
run = 1;
state = 0; ch = 0; port = 0; value = 0; while (run)
{ ch = line [ x ]; switch (state)
{ case 0 :
{ if ( ch >= '0' && ch <= '9' )
{ port = port * 10 + ( ch '0' );
} else if ( ch == ',' )
{
state = 1;
}
}
Modero X® Series G5 Touch Panels - Configuration & Programming Manual
Appendix F: DragDrop.axi
199
case 1 :
{ if (ch >= '0' && ch <= '9' )
{ value = value * 10 + ( ch '0' )
} else if (ch == ':')
{
run = 0;
} else if ( ch == '}' )
{
run = 0;
}
}
} x ++;
} return x ;
}
DEFINE_FUNCTION INTEGER __DRAG_DROP_PARSE_NAME ( CHAR line [],
INTEGER start ,
CHAR value [])
{
STACK_VAR INTEGER end ; value = '' ; end = FIND_STRING ( line , ':' , start );
if( end <= 0)
{ end = FIND_STRING ( line , '}' , start );
}
if( end > start)
{ value = MID_STRING ( line , start , end-start );
return end +1;
} return start +1;
}
DEFINE_FUNCTION INTEGER __DRAG_DROP_PARSE_VALUE ( CHAR line [],
INTEGER start ,
INTEGER value )
{
STACK_VAR INTEGER x , run;
STACK_VAR INTEGER ch ; x = start ;
run = 1 ; ch = 0; value = 0; while (run)
{ ch = line [ x ] if ( ch >= '0' && ch <= '9')
{ value = value * 10 + ( ch '0' );
} else if ( ch == ':' )
{
run = 0;
} else if ( ch == '}' )
{
run = 0;
} x ++;
} return x ;
}
Modero X® Series G5 Touch Panels - Configuration & Programming Manual
Appendix F: DragDrop.axi
200
Appendix F: DragDrop.axi
DEFINE_FUNCTION __DRAG_DROP_PARSE_DRAG_START ( INTEGER panel , TCUSTOM s )
{
STACK_VAR char line [200],text[2000];
STACK_VAR INTEGER length ,index; length = 0;
__DRAG_DROP_CLEAR_DATA ( panel );
text = s .
text ; line = REMOVE_STRING (text,"10",1); length = LENGTH_STRING ( line ); while ( length > 0)
{ if ( FIND_STRING ( line , 'dr{' ,1) == 1)
{
index = 4; while (index < length )
{
SELECT
{
ACTIVE ( FIND_STRING (line, 'ch=' ,index) == index) :
{
index = __DRAG_DROP_PARSE_PORT_VALUE ( line ,index+3,
__DRAG_DROP_current_drag [ panel ].
chanPort ,
__DRAG_DROP_current_drag [ panel ].
chan );
}
ACTIVE ( FIND_STRING (line, 'ad=' ,index) == index) :
{
index = __DRAG_DROP_PARSE_PORT_VALUE ( line ,index+3,
__DRAG_DROP_current_drag [ panel ].
addrPort ,
__DRAG_DROP_current_drag [ panel ].
addr );
}
ACTIVE ( FIND_STRING (line, 'gp=' ,index) == index) :
{
index = __DRAG_DROP_PARSE_NAME ( line ,index+3,
__DRAG_DROP_current_drag [ panel ].
groupName );
}
ACTIVE ( FIND_STRING (line, 'nm=' ,index )== index) :
{
index = __DRAG_DROP_PARSE_NAME ( line ,index+3,
__DRAG_DROP_current_drag [ panel ].
buttonName );
}
ACTIVE (1) :
{
index = length ;
}
}
}
} else if ( FIND_STRING ( line , 'dt{' ,1) == 1)
{
index = 4;
__DRAG_DROP_target_count [ panel ]++; while (index < length)
{
SELECT
{
ACTIVE ( FIND_STRING (line, 'vl=' ,index) == index) :
{ if ( line [index+3] == '1' )
{
__DRAG_DROP_current_targets [ panel ][ __DRAG_DROP_target_count [ panel ]].
valid = 1;
} else
{
__DRAG_DROP_current_targets [ panel ][ __DRAG_DROP_target_count [ panel ]].
valid = 0;
}
index = index+5;
}
ACTIVE ( FIND_STRING (line, 'ch=' ,index) == index) :
{
index = __DRAG_DROP_PARSE_PORT_VALUE ( line ,index+3,
__DRAG_DROP_current_targets [ panel ][ __DRAG_DROP_target_count [ panel ]].
chanPort ,
__DRAG_DROP_current_targets [ panel ][ __DRAG_DROP_target_count [ panel ]].
chan );
}
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 201
Appendix F: DragDrop.axi
ACTIVE ( FIND_STRING (line, 'ad=' ,index) == index) :
{
index = __DRAG_DROP_PARSE_PORT_VALUE ( line ,index+3,
__DRAG_DROP_current_targets [ panel ][ __DRAG_DROP_target_count [ panel ]].
addrPort ,
__DRAG_DROP_current_targets [ panel ][ __DRAG_DROP_target_count [ panel ]].
addr );
}
ACTIVE ( FIND_STRING (line, 'nm=' ,index) == index) :
{
index = __DRAG_DROP_PARSE_NAME ( line ,index+3,
__DRAG_DROP_current_targets [ panel ][ __DRAG_DROP_target_count [ panel ]].
buttonName );
}
ACTIVE (1) :
{
index = length ;
}
}
}
} line = REMOVE_STRING (text,"10",1); length = LENGTH_STRING ( line );
}
SET_LENGTH_ARRAY ( __DRAG_DROP_current_targets [ panel ], __DRAG_DROP_target_count [ panel ]);
}
DEFINE_FUNCTION __DRAG_DROP_PRINT_DATA ( INTEGER panel )
{
STACK_VAR INTEGER x ;
SEND_STRING 0,"FORMAT( 'drag ch=%d' , __DRAG_DROP_current_drag [ panel ].
chanPort ),
FORMAT( ',%-5d' , __DRAG_DROP_current_drag [ panel ].
chan ),
FORMAT( 'ad=%d' , __DRAG_DROP_current_drag [ panel ].
addrPort ),
FORMAT( ',%-5d' , __DRAG_DROP_current_drag [ panel ].
addr ),
'gp=''' , __DRAG_DROP_current_drag [ panel ].
groupName , ''' bn=''' ,
__DRAG_DROP_current_drag .
buttonName , '''' "; for ( x = 1; x <= __DRAG_DROP_target_count [ panel ]; x ++)
{
SEND_STRING 0,"FORMAT( 'target ch=%d' , __DRAG_DROP_current_targets [ panel ][ x ].
chanPort ),
FORMAT( ',%-5d' , __DRAG_DROP_current_targets [ panel ][ x ].
chan ),
FORMAT( 'ad=%d' , __DRAG_DROP_current_targets [ panel ][ x ].
addrPort ),
FORMAT( ',%-5d' , __DRAG_DROP_current_targets [ panel ][ x ].
addr ),
'bn=''' , __DRAG_DROP_current_targets [ panel ][ x ].
buttonName ,
FORMAT( ''' valid=%d' , __DRAG_DROP_current_targets [ panel ][ x ].
valid )";
}
}
Modero X® Series G5 Touch Panels - Configuration & Programming Manual 202
© 2018 Harman. All rights reserved. Metreau, NetLinx, AMX, AV FOR AN IT WORLD, HARMAN, and their respective logos are registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their respective companies. AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time. The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
LAST REVISED:
1/3/2018
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Unit C, Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
advertisement
Key Features
- 19-inch display
- Built-in camera and microphone
- Support for wired and wireless connectivity
- Control home theater system, lighting, and security system
- Built-in motion sensor
- Proximity sensor
- Ambient light sensor
- Capacitive touch technology
Frequently Answers and Questions
What is the difference between the MXT-1901-PAN and the MXT-1001?
Can I use the MXT-1901-PAN to control my home theater system?
Does the MXT-1901-PAN have a built-in motion sensor?
Related manuals
advertisement
Table of contents
- 14 Modero X Series G5 Configuration & Programming
- 14 Overview
- 14 Transitioning from G4 to G
- 14 Using the "Pipe" ( | ) Character
- 14 Touch Panel Aspect Ratio
- 15 Active Video Windows - Limitations
- 15 Additional Documentation
- 16 MXR-1001 Retractable Touch Panels
- 16 Overview
- 16 MXR-1001 Motor Controller
- 16 Powering On/Off the MXR-1001 Touch Panel
- 17 Raising and Lowering the MXR-1001 Touch Panel
- 17 Warning Screen
- 17 Audio Alert
- 18 Locking and Unlocking the MXR
- 18 MXR-1001 Send Commands
- 18 Motor Controller State Reporting
- 19 MXR-1001 Motor Controller State Table
- 19 MXR-1001 Motor Controller LED Behavior
- 19 Configuration and Programming
- 20 Settings Menu
- 20 Overview
- 20 Accessing the Settings Menu
- 20 If the Sleep/Settings Button Has Been Disabled
- 20 Press and Hold the Sleep/Settings Button During Bootup
- 20 Via the "G5:setup" SSH Command (Standard Security mode only)
- 21 Using AMX System Recovery
- 21 Using the Settings Menu
- 22 Settings Pages - G5 Menu Bar Options
- 22 Settings Pages - Application Specific Options
- 22 Settings Menu - Page Categories
- 23 Opening Settings pages
- 23 Closing the Settings menu
- 24 INFO - Device Info
- 24 DEVICE
- 24 NETLINX MASTER
- 24 MEMORY AND FILES
- 25 INFO - Maintenance
- 25 Rebooting the Panel
- 25 Shutting Down the Panel
- 26 DEVICE - Storage
- 26 INTERNAL STORAGE
- 26 USB STORAGE
- 27 Internal Storage: Audio
- 27 Internal Storage: Downloads
- 27 Internal Storage: Cached Data
- 27 USB Storage
- 27 Unmounting a USB Storage Device
- 28 DEVICE - Sound
- 28 DEVICE SOUNDS
- 28 SYSTEM SOUNDS
- 29 Selecting a Panel Raise and Lower Sound (MXR-1001 only)
- 29 Adjusting Volumes
- 30 Selecting Device Sounds
- 31 Selecting a Default Notification Sound
- 31 DEVICE - Display
- 31 Adjusting Panel Brightness
- 32 Adjusting Display Timeout
- 32 Selecting the Font Size
- 32 Calibration Test
- 33 DEVICE - G5 Settings
- 33 REMOTE PROFILE
- 33 INACTIVITY
- 33 PASSWORD PROTECTION
- 33 HTTPS CLIENT
- 33 Setting a Remote Profile
- 34 Setting an Inactivity Time Period and Page Flip
- 34 Setting Password Protection
- 35 DEVICE - Camera
- 35 Streaming Video
- 35 Entering a Streaming Video URL
- 35 Clearing the Current Streaming Video URL
- 36 DEVICE - Sensors
- 36 Calibrating the Light Sensor
- 37 DEVICE - VNC
- 37 Enabling VNC
- 37 Configuring VNC Access
- 38 DEVICE - Content Sharing
- 38 Enabling Content Sharing on the Panel
- 38 Configuring the Receivers List
- 38 Scanning the Network for Enzo Units
- 39 Manually Adding an Enzo to the Receivers List
- 40 Using Content Sharing
- 41 DEVICE - SIP
- 41 Configuring the Panel for use with a SIP Server
- 42 Enabling SIP Functionality on the Panel
- 42 Custom Ringtones & Ringback Tones
- 42 Customizing the Ringtone
- 42 Customizing the Ringtone For Particular Caller Numbers
- 42 Customize Ringback Tone
- 43 CONNECTIONS - Ethernet
- 44 Setting Static IP Information (IPv4)
- 45 Entering a New Hostname (IPv4/DHCP only)
- 45 Setting IPv6 Information
- 46 Working With 802.1x Security
- 47 CONNECTIONS - NetLinx
- 48 Scanning for Masters
- 48 Changing the Master Connection Mode
- 49 Changing the Master IP/URL
- 49 Changing the Master Port Number
- 49 Changing the Master Username
- 49 Changing the Master Password
- 49 Changing the Device Number and Device Name
- 49 Enabling a Secure Master Connection
- 50 Enabling Hostname Verification
- 50 CONNECTIONS - Browser
- 50 Adding a URL to the URLs List
- 51 Switching Between Desktop and Mobile Content
- 51 Deleting a URL from the URL’s List
- 51 CONNECTIONS - Multi Preview
- 51 Configuring the Panel To Accept Multi Preview Signals
- 52 CONNECTIONS - Bluetooth
- 53 CONNECTIONS - NFC
- 53 NFC Commands
- 53 NFC Read tag custom event
- 53 Streaming video custom event
- 54 CONNECTIONS - Smart Card
- 54 ACCOUNTS - Add an Account
- 54 Adding an Account
- 55 SYSTEM - Date & Time
- 55 Retrieving the Date and Time From NTP
- 55 Manually Setting the Date and Time
- 56 Specifying a Network Time Server
- 56 Manually Setting the Time Zone
- 57 Specifying a Date Format
- 57 SYSTEM - Language & Input
- 57 KEYBOARD & INPUT METHODS
- 57 PHYSICAL KEYBOARD
- 57 MOUSE/TRACKPAD
- 57 Selecting the Panel’s Language
- 58 Personal Dictionary
- 58 Changing Input Methods
- 60 Changing the Pointer Speed
- 60 SYSTEM - Security
- 60 SECURITY PROFILE
- 61 PROTECTED ACCESS
- 61 PASSWORDS
- 61 DEVICE ADMINISTRATION
- 62 Placing the Panel in High Security Mode
- 62 SYSTEM SERVICES
- 62 APPLICATIONS
- 62 CREDENTIAL STORAGE
- 62 DEFAULT SECURITY SYSTEMS
- 63 Switching From High Security Mode to Standard Security Mode
- 64 Changing the Password
- 64 Changing USB Security Settings
- 65 Displaying Trusted Credential Certificates
- 65 Installing Credential From Storage
- 66 Clearing Credentials
- 66 Restoring the Default System Security Settings
- 66 SYSTEM - Reset and Update
- 67 Factory Data Reset
- 67 Reset Settings
- 67 DEVICE RESET
- 67 UPDATE MANAGER
- 67 PANEL PAGES
- 68 Storing and Loading Settings Configuration Files
- 68 Storing the Current Settings
- 68 Loading Settings
- 69 Firmware Manager
- 69 Reverting to Previous Firmware
- 69 Reverting to Factory-Installed Firmware
- 69 Installing New Firmware From An External USB Stick
- 70 Install Firmware From Web
- 72 App Manager
- 72 App Manager Page - AVAILABLE tab
- 72 Installing All Available Updates
- 72 Updating Individual Applications
- 72 Enabling Native (Disabled) Applications
- 73 Installing Downloaded Applications
- 73 Installing Applications From an External USB Drive
- 74 App Manager Page - INSTALLED tab
- 74 Disabling Native Applications
- 74 Uninstalling Downloaded Applications
- 74 Scheduled Updates
- 74 Scheduled Application Updates
- 75 Scheduled Update Days
- 75 Scheduled Update Time
- 75 Update Applications on Startup
- 75 Installing Panel Pages From an External Disk
- 76 Removing User Pages From the Panel
- 77 SYSTEM - Diagnostics
- 78 Using Content Sharing
- 78 Overview
- 78 Content Sharing Icon
- 78 Notes on Content Sharing
- 79 Sharing Content From a Modero X G5 Touch Panel
- 79 1) Select a File and press the Content Sharing Icon
- 80 2) Select the Enzo To Send Shared Content To (if prompted)
- 81 3) On the Enzo, Confirm the Share Request (if prompted)
- 81 Error Messages
- 82 Gestures
- 82 Overview
- 82 Touch Gesture Recognition
- 82 Gesture Velocity
- 82 Gesture Prioritization
- 83 Gesture VNC/Mouse Support
- 83 Gesture Custom Event
- 83 Gesture numbers and velocity values
- 83 Precise gesture velocity
- 83 Enabling or Disabling the Gesture Custom Event
- 84 MXA-MP and MXA-MPL Programming
- 84 Overview
- 84 Configuring the Touch Panel
- 84 Stand-Alone Images and Video Feeds
- 84 Adding a Preview Image to a Touch Panel Page
- 85 Adding a Live Motion Stream To A Touch Panel Page via an MXA-MPL
- 85 Supported Resolution/Signal Type Commands
- 86 Code-Driven Buttons and Video Feeds
- 87 Programming - Send Commands
- 87 Overview
- 87 Using the "Pipe" ( | ) Character
- 87 Panel Commands
- 87 ABEEP
- 87 ADBEEP
- 87 AKEYB
- 88 AKEYP
- 88 AKEYR
- 89 ^APP - Launch application chooser
- 89 ^APP - Launch application window
- 89 ^APP - Close a specific application
- 90 ^APP - Application action
- 93 LEVON
- 93 LEVOF
- 96 PKEYB
- 96 PKEYP
- 97 SHUTDOWN
- 97 SLEEP
- 98 SETUP
- 98 TPAGEOF
- 98 TPAGEON
- 99 UPDATE
- 101 Page Commands
- 137 Text Effect Name/Numbers
- 138 Dynamic Image Commands
- 139 ^RFRP
- 141 ^RAF and ^RMF Embedded Codes / Escape Sequences
- 142 Intercom Commands
- 142 ^ICM-LISTEN
- 142 ^ICM-MUTEMIC
- 142 ^ICM-SPEAKERLEVEL
- 142 ^ICM-TALK
- 143 ^MODEL?
- 144 SIP Commands
- 144 Panel to Master
- 144 ^PHN-AUTOANSWER
- 144 ^PHN-CALL
- 144 ^PHN-INCOMING
- 144 ^PHN-LINESTATE
- 144 ^PHN-MSGWAITING
- 145 Master to Panel
- 145 ^PHN-ANSWER
- 145 ^PHN-AUTOANSWER
- 145 ?PHN-AUTOANSWER
- 145 ^PHN-PRIVACY
- 145 ^PHN-REDIAL
- 145 ^PHN-TRANSFERRED
- 146 ^PHN-CALL
- 146 ^PHN-DECLINE
- 146 ^PHN-DTMF
- 146 ^PHN-HANGUP
- 146 ^PHN-HOLD
- 146 ?PHN-LINESTATE
- 146 ^PHN-PRIVACY
- 147 ?PHN-PRIVACY
- 147 ^PHN-REDIAL
- 147 ^PHN-TRANSFER
- 147 ^PHN-SETUP-CODEC
- 147 ^PHN-SETUP-DOMAIN
- 147 ^PHN-SETUP-DTMFDURATION
- 147 ^PHN-SETUP-ENABLE
- 148 ^PHN-SETUP-PASSWORD
- 148 ^PHN-SETUP-PORT
- 148 ^PHN-SETUP-PROXYADDR
- 148 ^PHN-SETUP-USERNAME
- 149 Listview (Data Access) Commands
- 149 Terminology
- 149 DataFeed
- 149 DataRecord
- 149 DataField
- 155 Notes on Using Image URLs With Listview Buttons
- 156 Streaming Video, MXA-MP, and MXA-MPL Commands
- 156 ^SLT reboot
- 156 ^SLT start
- 157 ^SLT stop
- 157 ^SLT videomode
- 157 ^SLT audiovideoenable
- 157 ^SLT videoinput
- 158 Notes on Using the ^SDM and ^SLT Commands
- 159 VNC Commands
- 161 MXR-1001 Send Commands
- 163 Data Event - ONERROR
- 164 ONERROR Error Codes
- 165 Programming Numbers
- 165 Color Table
- 166 Justification Values
- 167 Border Styles
- 168 ISO-8859-1 Character Encoding/Decoding table
- 168 Resource Escape Codes
- 169 Virtual Keystroke Commands
- 170 SSH Commands
- 170 Overview
- 170 clear
- 171 debug
- 171 logout
- 171 g5:cache
- 171 g5:config
- 171 g5:profile
- 171 g5:prof
- 172 g5:sensor
- 172 g5:settings
- 172 g5:setup
- 172 g5:touch
- 172 g5:version
- 172 g5:ver
- 172 g5:webu
- 173 g5:window-stats
- 173 g5:ws
- 173 history
- 174 motor (MXR-1001 only)
- 176 netlinx
- 176 reboot
- 176 scope
- 177 support
- 179 Appendix A: Upgrading Firmware via NetLinx Studio
- 179 Overview
- 179 NetLinx Studio
- 179 Upgrading Firmware via NetLinx Studio (v4 or Higher)
- 181 HTTP Server Transfer Error
- 182 Appendix B: Using NetLinx to Define a Data Source (Listview Buttons)
- 182 Example Listview Workflow - NetLinx Data Source
- 182 1) Create the Listview Button and Set Button Properties
- 183 List View Components
- 184 Item Height
- 184 List View Columns
- 184 List View Item Layout
- 184 Primary Partition (%)
- 184 Secondary Partition (%)
- 185 2) Create the Data Source
- 185 Filter Enabled
- 185 Filter Height
- 185 Alphabet Scrollbar
- 185 Dynamic Data Source
- 186 NetLinx Usage Example - ASCII
- 188 3) Configure the Response to a User Selection
- 189 Appendix C: Text Formatting
- 189 Text Formatting Codes for Bargraphs
- 190 Text Area Input Masking
- 190 Input mask character types
- 190 Input Mask Ranges
- 191 Input Mask Operations
- 191 Input Mask Literals
- 191 Input Mask Output Examples
- 191 URL Resources
- 192 Special Escape Sequences
- 193 Appendix D: Bargraph Functions
- 193 Overview
- 193 Setup Codes
- 194 Appendix E: Video Streaming
- 194 Optimizing Motion JPEG Video Presentation and Speed
- 194 Streaming a Video File Saved on the Panel via Custom URL Scheme
- 196 Transcoding Guidelines
- 197 NMX-ENC H.264 Encoder - Encoder Settings for G5 Panels
- 198 Appendix F: DragDrop.axi
- 198 Overview