AMX MXD-430 touch panels Quick Start Guide

AMX MXD-430 touch panels Quick Start Guide

QUICK START GUIDE

MXD-430

4.3" Modero X® Series Wall/Flush Mount Touch Panel

Overview

The MXD-430 4.3” Modero X Series Wall/Flush Mount Touch Panel (

FG5968-15

will complement even the most sophisticated meeting facilities and homes. ) features edge-to-edge capacitive touch glass with multi-touch capabilities as well as advanced technology empowering users to operate AV equipment seamlessly, while providing the ultimate in audio and video quality. The distinctive appearance Left LED Right LED

Power via PoE

Power for the MXD-430 is supplied via Power Over Ethernet (PoE), utilizing an AMX-certified, capacitive touch-compliant PoE injector such as the PS-POE-AF TC High Power PoE Injector (

FG423-83

) or other approved AMX PoE power source. The incoming Ethernet cable should be connected to the RJ45 port on the MXD 430 (FIG. 2). Front Access Slot front rear

FIG. 1

MXD-430

Product Specifications

MXD-430 SPECIFICATIONS

Dimensions (HWD) Weight Power Consumption External Power Supply Required Certifications Environmental Included Accessories 4 7/8" x 3 1/4" x 2 3/8" (120 mm x 82 mm x 61 mm) 0.75 lbs (.34 Kg) • Full-On: 6.5W

• Standby: 4.2W

• Shutdown: 1.9W

• Start-Up Inrush Current: Not applicable due to PoE standard Optimal performance requires use of one of the following AMX PoE power supplies (not included): • PS-POE-AF-TC, PoE Injector, 802.3AF Compliant (FG423-83) • NXA-ENET8-2POE, Gigabit PoE Ethernet Switch (FG2178-63) • UL 60950-1 • FCC Part 15 Class B • C-Tick CISPR 22 Class B • CE EN 55022, EN 55024 and EN 60950-1 • IEC 60950-1 • IC • IEC/EN-60950 • RoHS / WEEE compliant • Temperature (Operating): 32°F to 104°F (0°C to 40°C) • Temperature (Storage): 4°F to 140°F (-20°C to 60°C) • Humidity (Operating): 20% to 85% RH • Humidity (Storage): 5% to 85% RH • Power ("Heat") Dissipation: On: 22.2 BTU/hr Standby: 14.3 BTU/hr • MXA-USB-C, USB Port Cover Kit (FG5968-18) • MXA-CLK, Modero X/S Series Cleaning Kit (FG5968-16) • MXD-430 Installation Template

Connector Locations

USB peripherals (mouse, keyboard, etc.) may be connected to either of the two USB ports on the rear of the device (see FIG. 1). The connectors are accessible

via the Access Slot shown in FIG. 2. and FIG. 3.

Updates to the device’s firmware can also made via the USB ports. USB Port RJ45 Port

FIG. 2

BOTTOM VIEW - SHOWING RJ45 AND USB PORTS

Installing the MXD-430 Into a Wall

The MXD-430 comes with a clear plastic Backbox (designed to attach the panel to most standard wall materials. This Backbox has two locking tabs (one on each side) to help lock the Backbox to the wall. These locking tabs are only extended AFTER the Backbox is inserted into the wall (FIG. 3).. Backbox Locking Tab Access Slot

FIG. 3

MXD-430 BACK BOX (SIDE VIEW) • When installing the Backbox, make sure that the assembly is in the correct position and in the correct place. Once the locking tabs are extended and locked into place, removing the Backbox may be difficult without having access to the back of the wall or causing damage to the wall. • In order to ensure a stable installation of the MXD-430, the thickness of the wall material must be a minimum of .50 inches (1.27cm) and a maximum of .875 inches (2.22cm). The mounting surface should also be smooth and flat.

Installing the Backbox

For best results, use the included Installation Template (

68-5968-05

) to ensure proper placement.

WARNING: Using the Installation Template to select the final placement of the Backbox is highly recommended. The outside edges of the template are the same dimensions as the touch panel, which allows you to troubleshoot possible conflicts with wall edges, doors, and other potential obstacles.

1.

Prepare the area by removing any screws or nails from the drywall before beginning the cutout process.

2.

3.

After ensuring proper placement, cut out the mounting surface, using the (included) Installation Template as a guide.

CAUTION: Making sure the actual cutout opening is slightly smaller than the provided dimensions is highly recommended. This action provides a margin for error if the opening needs to be expanded. Too little wall material removed is always better than too much.

Thread the incoming Ethernet cable through the surface opening.

Leave enough slack in the wiring to accommodate any re-positioning of the panel.

4.

Remove the knockout from the backbox to open the access slot (FIG. 3), and

thread the incoming wiring through the hole 5.

6.

7.

8.

Push the backbox flat into the mounting surface and secure with either the locking tabs or #4 mounting screws (not included). Extend the locking tabs on the sides of the Backbox by tightening the screws inside the box until snug. Apply enough pressure to the screw head to keep the box flush with the wall: this ensures that the locking tabs will tighten up against the inside of the wall.

The Backbox is clear to allow visual confirmation that the tabs have been extended and are gripping the wall, as well as in assisting with removal if necessary.

Note: The maximum recommended torque to screw in the locking tabs on the Backbox is 5 IN-LB [56 N-CM]. Applying excessive torque while tightening the tab screws, such as with powered screwdrivers, can strip out the locking tabs or damage the Backbox.

For additional strength, #4 mounting screws (not included) may be secured via mounting holes located at the corners of the MXD-430 (see FIG. 1). In order to prevent damage to the touch panel, make sure that any screws used are flush with the back box, and the back box goes freely into the opening.

Insert each connector into its corresponding location along the back of the MXD-430.

9.

Test the incoming wiring by attaching the panel connections to their terminal locations and applying power. Verify that the panel is receiving power and functioning properly to prevent repetition of the installation.

Note: Do not disconnect the connectors from the touch panel. The unit must be installed with the attached connectors before being inserted into the drywall.

Remove power before continuing with the installation.

10. Latch the panel onto the bottom hooks on the back box and rotate it up. Press gently but firmly and evenly on the surface of the glass until the top panel snap “clicks” to lock it down.

WARNING: if you see a gap between the panel and the back box, or feel any binding while locking down the panel, stop immediately and verify that no cables or other items are in the way. Do not force the panel into position, as this can cause damage to the touch screen or the panel electronics.

11. Reconnect the terminal Ethernet and USB to their respective locations on either the Ethernet port or NetLinx Master.

Powering On/Off X Series Panels

Modero X Series touch panels may be powered on by touching and holding the

Sleep

button. To power off the panel, press and hold the Sleep button, and select

Power Off

on the on-screen menu (FIG. 4):

FIG. 4

SLEEP BUTTON - PRESS AND HOLD TO ACCESS POWER OFF/SETTINGS OPTIONS

Configuration and Programming

X Series touch panels are equipped with a

Settings

menu that provides the ability to configure various features on the panels. To access the

Settings

menu, press and hold the Sleep button, and select 1.

In the Settings menu, select

Settings

.

Note: Information on the Settings menu, panel configuration, and programming is provided in the Modero X Series Programming Guide, available at www.amx.com.

Setting the Panel’s Device Number and Device Name NetLinx

. This opens a password keypad.

2.

Enter the panel password into the keypad (the default is

1988

) and select

OK

to access the

NetLinx

page.

3.

4.

5.

Press

Device Number

to open the NetLinx editing window.

Enter a unique Device Number assignment for the panel and press

OK

.

Enter a unique Device Name assignment for the panel and press

OK

.

Configuring the Panel’s IP Address

These steps configure the panel to communicate with a network; it is still necessary to connect to the NetLinx Master (see

Connecting to a NetLinx Master

below).

Network Communication via DHCP

1.

In the

Ethernet

page, press

DHCP/Static

field to open the

DHCP/Static

window. Note that

DHCP

is the default setting.

2.

3.

Select Press

Host Name OK

, enter the new host name to save changes.

Network Communication via Static Address

1.

In the

Ethernet

page, press

DHCP/Static

to open the

DHCP/Static

window.

2.

3.

Select

Static

to open the

Static IP

window.

Press any field to open a keypad or keyboard (depending on the field), and enter the appropriate network address information.

4.

Press

OK

to save your changes and return to the

Ethernet

page.

Connecting to a NetLinx Master

To establish the type of connection to make between the panel and the NetLinx Master: 1.

In the

NetLinx

page, press

Mode

to choose the connection mode (

URL

,

Listen

or

Auto

):

CONNECTION MODES Mode Description Procedures

URL The device connects to the target Master’s IP address via a TCP connection.

Listen This mode allows the panel to “listen” for the Master’s communication signals. Note that in this mode, the

System Number

and

Master IP/URL

fields are read-only.

Auto Use this mode when both the panel and the NetLinx Master are on the same Subnet.

1) Select

URL

in the

Mode

menu.

2) Enter the

Master IP/URL

,

Master Port Number

, and

Username

/

Password

(if required by the Master).

Press

OK

to save changes.

1) Select 3) Press

Listen OK

in the

Mode

menu.

2) Confirm the panel’s IP address is on the Master’s URL list (via NetLinx Studio).

to save changes.

Note: The Host Name (set on the Ethernet page), can be used to locate the panel on the Master (particularly useful for DHCP connections where the IP address can change).

1) Select 3) Press

Auto OK

in the

Mode

menu.

2) Enter the System Number and Username and Password (if applicable). to save changes.

2.

If password security is enabled on the target Master, enter the Username and Password: a. Select

Username

to open the

NetLinx

window.

b. Enter the

Username

and

Password

required by the Master.

c. Press

OK

information.

to save changes and return to the

NetLinx

page.

Related Software and Additional Documentation (at www.amx.com)

• Programming the Modero X Series touch panels requires the use of the latest versions of NetLinx Studio and TPDesign4, both available to download at www.amx.com. Refer to the NetLinx Studio and TPDesign4 online help for • For additional information on the MXD-430 panel, refer to the

X-Series Touch Panels MXD/T-1000, MXD/T-700 and MXD-430 Instruction Manual.

• For detailed information on the Settings menu as well programming information and instructions on upgrading firmware, refer to the

Modero X Series Programming Guide

.

Last Revised: 6/22/2015 © 2015 Harman. All rights reserved. Modero X and Modero X Series, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their respective companies.

AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.

The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153

AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/

93-5968-15 REV: H

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF