PR LIGHTING JNR PAR 36 18x3 User Manual

Add to my manuals
6 Pages

advertisement

PR LIGHTING JNR PAR 36 18x3 User Manual | Manualzz

PR LIGHTING LTD.

http://www.pr-lighting.com

1582 Xingye Avenue, Nancun Panyu

Guangzhou, 511442 China

TEL: +86-20-3995 2888

JNR PAR 36 18*3

JNR-8017

1

SAFETY INSTRUCTIONS

CAU T I O N

Becareful with your operations.With a dangerous voltage you cansuffer a dangerous electric shock when touching wires!

This device has left the factor y in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessar y for the user to follow the safety instructions and warning notes written in this user manual.

IMPORTANT

Damages caused by the disregard of this user manual are not subject to warranty.

The dealer will not accept liability for any resulting defects or problems.

If the device has been exposed to temperature changes due to environmental changes, do not switch it on immediately. The arising condensation could damage the device.

Leave the device switched off until it has reached room temperature.

This device falls under protection-class I. Therefore it is essential that the device be earthed.

The electric connection must carr y out by qualified person.

The device shall only be used with rate voltage and frequency.

Make sure that the available voltage is not higher than stated at the end of this manual.

Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, replacement of the cable must be done by an authorized dealer.

Always disconnect from the mains, when the device is not in use or before cleaning it.

Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.

During initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective, it should decrease gradually.

Please don't project the beam onto combustible substances.

Fixtures cannot be installed on combustible substances, keep more than 50cm distance with wall for smooth air flow, so there should be no shelter for fans and ventilation for heat radiation.

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his ser vice agent or a similar qualified person in order to avoid a hazard.

.01.

10

MAINTENANCE AND CLEANING

The following points have to be considered during the inspection:

1) All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded.

2) There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling, suspension, trussing).

3) Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances.

4) The electric power supply cables must not show any damage, material fatigue or sediments.

Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.

CAU T I O N

Disconnect from mains before starting maintenance operation.

In order to make the lights in good condition and extend the life time, we suggest a regular cleaning to the lights.

1) Clean the inside and outside lens each week to avoid the weakneness of the lights due to accumulation of dust.

2) Clean the fan each week .

3) A detailed electric check by approved electrical engineer each three month, make sure that the circuit contacts are in good condition, prevent the poor contact of circuit from overheating.

We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth.

Never use alcohol or solvents.

There are no ser viceable parts inside the device. Please refer to the instructions under “Installation instructions”.

Should you need any spare parts, please order genuine parts from your local dealer.

.10.

9

DMX CHANNELS

3CH Mode

Channel Function Value

1 Red 0-255

2

3

Green

Blue

0-255

0-255

Description

0-100% Red dimmer

0-100% Green dimmer

0-100% Blue dimmer

8CH Mode

Channel Function Value

1 Dimmer 0-255

2

3

Red

Green

0-255

0-255

4

5

Blue

Strobe

6

7

8

Auto

Speed

Sound

Control

0-255

0-015

016-255

0-015

016-255

0-255

0-127

128-255

Description

0-100% Linear dimmer

0-100% Red dimmer

0-100% Green dimmer

0-100% Blue dimmer

LED OFF

Strobe effect from slow to fast

LED OFF

Auto color mixing from slow to fast

Speed of auto color mixing and strobe from slow to fast

Sound control OFF (from controller)

Sound control ON (from controller)

2

UNPACKING

Thank you for choosing JNR PAR 36 18*3. For your own safety, please read this manual before installing the device. This manual covers the important information on installation and applications. Please install and operate the fixture with following instructions. Meanwhile, please keep this manual well for future needs.

JNR PAR 36 18*3 is made of a new type of high temperature strength of cast aluminum casing with nice outlook . The fixture is designed and manufactured strictly following CE standards, complying with international standard DMX512 protocol. It’s available independently controlled and linkable with each other for operation. And it is applicable for large-scale live performances, theater, studio, nightclubs and discos.

JNR PAR 36 18*3 adopts 18PCS high power 3W LEDs (R,G,B) which features high brightness and stability. Please carefully unpack it when you receive the fixture and check whether it is damaged during the transportation. And please check whether the following items are included inside the box:

.09.

OPTIONAL

USA Standard Euro Standard UK Standard

.02.

JNR PAR 36 10*3

Power Cable

Safety Cable

User Manual

1PC

1PC

1PC

1PC

3

FEATURES & SPECIFICATIONS

Features

• 18PCS 3W LEDs (R,G,B)

• Specific optic system in 25 degree

• Good light output with 260LUX@7M at full RGB

• 50,000 hours life span and low power consumption

• Smooth and even color mixing

• High efficiency LED shutter with variable speed

• Smooth LED linear dimmer

• LED rainbow effect

• 8 built-in default programs

• Strobe effect with 18 flashes per second and pulse effect

• General dimming and blackout for all four colors

• 3/8 DMX Channels USITT DMX-512

• DMX512, master-slave and sound activated controllable or auto operation

• LED display

• Efficient low noise cooling system

• 3-pin XLR connectors IN/OUT

• -25°C~+35°C ambient temperature

Specifications

Input Voltage:

LED Quantities:

AC90-240V 50/60Hz

18PCS 3W LEDs (R,G,B)

Control Signal:

Control Channel:

DMX512, master-slave and sound activated or auto operation

3/8 DMX Channels USITT DMX-512

Power Consumption: 95W

Dimensions:

Packing Dimensions:

Net Weight:

Gross Weight:

200(D)*140(W)*230(H)mm

260D)*185(W)*290(H)mm

1.16kg

1.52kg

3

1

3

2

DMX Output

3-Pin XLR Socket

DMX Input

3-Pin XLR Socket

1:Ground

2:Data(-)

3:Data(+)

1

2

3

DMX512 OUT

3-PIN XLR

COMMON

DMX+

DMX-

3

1

2

DMX512 IN

3-PIN XLR

For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor connected between pins 2 and 3,which is then plugged into the output XLR socket of the last fixture in the chain.

Please see illustrations below.

120 Ω

1

3

2

8

MENU OPERATIONS

Address setting

Channel mode

3CH

8CH

Master/Slave setting

PIN3

PIN2

Strobe with color changing

Color 1 to color 15

Speed control of color changing

(SP01-SP08)

Red dimmer

Green dimmer

Blue dimmer te5t

Color auto test R.G.B

Running Time(H)

.08.

.03.

Regardless of the rigging option you choose for your JNR PAR 36 18*3 , always be sure to secure your fixture with a safety cable. The fixture provides a built-in rigging point for a safety cable on the hanging bracket as illustrated above. Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carr ying handle.

7

DMX-512 CONTROL CONNECTIONS

Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-pin XLR input of the par can. You can chain multiple

Par can together through serial linking. The cable needed should be two core, screened cable with XLR input and output connectors. Please refer to the diagram below.

DMX-512 connection with DMX terminator

UP

FUNC

DMX

POWER IN

LED DISPLAY

ENTER

DMX

DOWN

POWER OUT

210

140

200 140

195

230

4

PHOTOMETRIC DATA

R

G

B

RGB

Photometric Beam Angle Data

122 / 1311

277 / 2985

429 / 4620

776 / 8352

25 ° Beam Angle LUX 0.0929=FC

15 / 162

12 / 390

55 / 594

99 / 1062

6 / 66

14 / 156

22 / 234

39 / 417

3 / 33

8 / 81

11 / 120

20 / 210 (FC/LUX)

25

°

DMX IN

POWER IN

I m p o r t a n t No t e s :

1. Please do not link more than PCS LEDPAR 36AM at AC220V voltage!

2. Please do not link more than PCS LEDPAR 36AM at AC110V voltage!

.07.

0m (0ft) 1m (3.3ft) 3m (9.8ft) 5m (16.4ft)

.04.

7m (23.0ft)

5

OPERATION INSTRUCTIONS

· The JNR PAR 36 18*3 is an LED wash light for on-site decoration purpose.

· Don’t turn on the fixture if it’s been through severe temperature difference like after transportation because it might damage the light due to the environment changes. So make sure to operate the fixture until it is in normal temperature.

· This light should be keep away from strong shaking during any transportation or movement.

· Don’t pull up the light by only the head, or it might cause damages to the mechanical parts.

· Don’t expose the fixture in overheat, moisture or environment with too much dust when installing it. And don’t lay any power cables on the floor. Or it might cause electronic shock to the people.

· Make sure the installation place is in good safety condition before installing the fixture.

· Make sure to put the safety chain and check whether the screws are screwed properly when installing the fixture.

· Make sure the lens are in good condition. It’s recommended to replace the units if there are any damages or severe scratch.

· Make sure the fixture is operated by qualified personnel who knows the fixture before using.

· Keep the original packages if any second shipment is needed.

· Don’t tr y to change the fixtures without any instruction by the manufacturer or the appointed repairing agencies.

· It is not in warranty range if there are any malfunctions from not following the user manual to operate or any illegal operation, like shock short circuit, electronic shock , lamp broke, etc.

6

INSTALLATIONS

Cautions: For added protection mount the fixtures in areas outside walking paths, seating areas, or in areas were the fixture might be reached by unauthorized personnel.

Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight.

Fixture installation must always be secured with a secondar y safety attachment, such as an appropriate safety cable.

Never stand directly below the device when mounting, removing, or servicing the fixture.

.05.

from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture 6

Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injur y in the event the clamp fails.

Mounting points: Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself.

Improper installation can result in bodily injur y.

Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet.

Clamp mounting: The JNR PAR 36 18*3 provides a unique mounting bracket assembly, and the safety cable rigging point in one unit (see the illustration below).

When mounting this fixture to truss be sure to secure an appropriately rated clamp to the handle using a M10 screw fitted through the center hole of the handle. As an added safety measure be sure to attached at least one properly rated safety cable to the fixture using on of the safety cable rigging point.

Satety Clamp Safety Cable

Floor projection

.06.

Truss installing

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement