PR LIGHTING JNR ELLIPSOIDAL 200ZD User Manual

PR LIGHTING JNR ELLIPSOIDAL 200ZD User Manual
PR LIGHTING LTD.
http://www.pr-lighting.com
1582 Xingye Avenue, Nancun Panyu
Guangzhou, 511442 China
TEL: +86-20-3995 2888
JNR ELLIPSOIDAL 200ZD
JNR-8142G
1 SAFETY INSTRUCTIONS
9
MAINTENANCE AND CLEANING
The following points have to be considered during the inspection:
CAU T I O N
Becareful with your operations.With a dangerous voltage you cansuffer a
dangerous electric shock when touching wires!
This device has left the factory in perfect condition. In order to maintain this
condition and to ensure a safe operation, it is absolutely necessary for the user to
follow the safety instructions and warning notes written in this user manual.
IMPORTANT
Damages caused by the disregard of this user manual are not subject to warranty.
The dealer will not accept liability for any resulting defects or problems.
If the device has been exposed to temperature changes due to environmental changes,
do not switch it on immediately. The arising condensation could damage the device.
Leave the device switched off until it has reached room temperature.
This device falls under protection-class I. Therefore it is essential that the device be
earthed.
1) All screws for installing the devices or parts of the device have to be tightly
connected and must not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and
installation spots (ceiling, suspension, trussing).
3) Mechanically moved parts must not show any traces of wearing and must not
rotate with unbalances.
4) The electric power supply cables must not show any damage, material fatigue or
sediments.
Further instructions depending on the installation spot and usage have to be
adhered by a skilled installer and any safety problems have to be removed.
CAU T I O N
Disconnect from mains before starting maintenance operation.
The electric connection must carry out by qualified person.
The device shall only be used with rate voltage and frequency.
Make sure that the available voltage is not higher than stated at the end of this manual.
Make sure the power cord is never crimped or damaged by sharp edges. If this would
be the case, replacement of the cable must be done by an authorized dealer.
Always disconnect from the mains, when the device is not in use or before cleaning it.
Only handle the power cord by the plug. Never pull out the plug by tugging the power
cord.
During initial start-up some smoke or smell may arise. This is a normal process and
does not necessarily mean that the device is defective, it should decrease gradually.
In order to make the lights in good condition and extend the life time, we suggest a
regular cleaning to the lights.
1) Clean the inside and outside lens each week to avoid the weakneness of the lights
due to accumulation of dust.
2) Clean the fan each week.
3) A detailed electric check by approved electrical engineer each three month, make
sure that the circuit contacts are in good condition, prevent the poor contact of
circuit from overheating.
Please don't project the beam onto combustible substances.
Fixtures cannot be installed on combustible substances, keep more than 50cm
distance with wall for smooth air flow, so there should be no shelter for fans and
ventilation for heat radiation.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively
replaced by the manufacturer or his service agent or a similar qualified person in order
to avoid a hazard.
.01.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth.
Never use alcohol or solvents.
There are no serviceable parts inside the device. Please refer to the instructions
under “Installation instructions”.
Should you need any spare parts, please order genuine parts from your local dealer.
.10.
8 DMX CHANNELS
2 UNPACKING
2CH Mode
Channel Function
1
2
Color 1
Color 2
Value
Description
0-255
0-255
Color 1 dimmer
Color 2 dimmer
5CH Mode
Channel Function
1
2
3
4
5
Dimmer
Color 1
Color 2
Strobe
Speed
Value
0-255
0-255
0-255
0-10
11-255
0-20
21-40
41-60
61-80
81-99
100-109
……
190-199
200-240
241-255
Description
Dimmer
Color 1 dimmer
Color 2 dimmer
No strobe
Speed of strobe (255 is the fastest)
Speed of dimmer 4 (the slowest and softest)
Speed of dimmer 3
Speed of dimmer 2
Speed of dimmer 1
Speed of dimmer off (fastest and no any delay)
Inner program 1
Each 10 data is a program
Inner program 10
Change color by sound control
Strobe by sound control
Thank you for choosing our JNR ELLIPSOIDAL 200ZD. For your own safety, please
read this manual before installing the device. This manual covers the important
information on installation and applications. Please install and operate the fixture
with following instructions. Meanwhile, please keep this manual well for future
needs.
The JNR ELLIPSOIDAL 200ZD is made of a new type of high temperature strength of
cast aluminum casing with nice outlook. The fixture is designed and manufactured
strictly following CE standards, complying with international standard DMX512
protocol. It’s available independently controlled and linkable with each other for
operation. And it is applicable for large-scale live performances, theater, studio,
nightclubs and discos.
The JNR ELLIPSOIDAL 200ZD adopts 1PCS 200W COB LEDs (available for Pure
White+Warm White) which features high brightness and stability. Please carefully
unpack it when you receive the fixture and check whether it is damaged during the
transportation. And please check whether the following items are included inside
②
OPTIONAL
③
USA Standard
Euro Standard
UK Standard
①
① JNR ELLIPSOIDAL
④
.09.
⑤
.02.
1PC
② Signal Cable
1PC
③ Power Cable
1PC
④ Safety Cable
1PC
⑤ User Manual
1PC
3 FEATURES & SPECIFICATIONS
COMMON
2
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1
1
3
1*200W COB LEDs (available for Pure White+Warm White )
50,000 hours life span and low power consumption
Color Rendering Index(CRI): Ra≥95
Optimized high definition optical system for improved photometric performance
and field uniformity
Projector-quality, high contrast aspheric lens
Glass reflector that removes greater than 90% infrared radiation (heat) and reflects
greater than 95% of visible light
Manual zoom system from 15°-38°
Flat and even spot image
Smooth manual focus system
Beam edge continually adjustable hard-to-soft
Housing made by rugged, die cast aluminum alloy
Thermally insulated rear handle
Thermally insulated knobs and single aluminum handle for installing
3 Metal spot cutting slots
Barn door included
Glass/Metal gobo slot as optional
Color frame as optional
Manual IRIS system as optional
0-100% Smooth and precise linear dimmer
25T/sec high speed shutter/strobe effect with variable speed
Preset variable/random strobe and dimming pulse effect
2/5 DMX channels USITT DMX-512
DMX512, master-slave, and sound control or auto operation
4-Button LCD display
POWRECON connector IN/OUT
Power switch available with fuse
3-Pin and 5-pin XLR connectors IN/OUT
Low noise fan integrated with copper liquid cooling system
-35-45°C Max ambient temperature
IP20 protection rating
1*Safety attachment point
.03.
2
3
1:Ground
2:Data(-)
3:Data(+)
1
2
For installations where the DMX cable has to run a long
distance or is in an electrically noisy environment, such as
in a discotheque, it is recommended to use a DMX
terminator. This helps in preventing corruption of the
digital control signal by electrical noise. The DMX
terminator is simply an XLR plug with a 120 Ω resistor
connected between pins 2 and 3,which is then plugged
into the output XLR socket of the last fixture in the chain.
Please see illustrations below.
3
2
DMX-
DMX512 OUT
3-PIN XLR
DMX Output
DMX Input
3-Pin XLR Socket 3-Pin XLR Socket
1
DMX+
3
DMX512 IN
3-PIN XLR
120 Ω
3
1
2
7 MENU OPERATIONS
a001
d001
at01
sod1
StAt
tEMP
a512
d512
at10
sp01
sod2
r000
g000
b000
st00
0
t040
Address setting
DMX setting
Auto run mode
sp20
Speed of auto run
Sound model
r2S5
g2S5
b2S5
st20
Static model Red dimmer
Green dimmer
Blue dimmer
Strobe mode
Current temperature
t120
Set the temperature protect
D SP
REST
Normal / Inversion Display
Reset
.08.
PIN3
PIN2
Regardless of the rigging option you choose for your JNR ELLIPSOIDAL 200ZD, always
be sure to secure your fixture with a safety cable. The fixture provides a built-in
rigging point for a safety cable on the hanging bracket as illustrated above. Be sure
to only use the designated rigging point for the safety cable and never secure a
safety cable to a carrying handle.
Specifications
Input Voltage:AC90-260V 50/60Hz
LED Quantities:1*200W COB LEDs (available for Pure White+Warm White )
Control Signal:DMX512, master-slave and sound activated or auto operation
Control Channel: 2/5 DMX channels USITT DMX-512
Power Consumption: 260W
Dimensions:195(D)*720(W)*415(H)mm
Packing List: 332(D)*832(W)*345(H)mm
Net Weight: 10.2kg
Gross Weight: 12.2kg
415
6 DMX-512 CONTROL CONNECTIONS
195
Connect the provided XLR cable to the female 3-pin XLR output of your controller and
the other side to the male 3-pin XLR input of the studio light. You can chain multiple
Studio light together through serial linking. The cable needed should be two core,
screened cable with XLR input and output connectors. Please refer to the diagram
below.
DMX-512 connection with DMX terminator
195
720
4 PHOTOMETRIC DATA
Photometric Beam Angle Data FC =LUX * 0.0929
7m
3-Pin DMX IN
5-Pin DMX IN
LED DISPLAY
5-Pin DMX OUT
ENTER
FUSE
DOWN
POWER OUT
Ground
3-Pin DMX OUT
FUNC
Power Switch
UP
POWER IN
15°
5m
38°
3m
1m
0m
<38°> 34150
3-Pin DMX IN
POWER IN
5-Pin DMX IN
BEAM
DIAMETER
( ø0.7 )
<15°> 102400
BEAM
DIAMETER
.07.
( ø0.3 )
4620
1780
( ø2.1 )
( ø3.4)
950
( ø4.8 ) m
11560
4420
2560
( ø0.8 )
( ø1.3)
( ø1.8 ) m
.04.
4 OPERATION INSTRUCTIONS
· The JNR ELLIPSOIDAL 200ZD is an LED wash light for on-site decoration purpose.
· Don’t turn on the fixture if it’s been through severe temperature difference like
after transportation because it might damage the light due to the environment
changes. So make sure to operate the fixture until it is in normal temperature.
· This light should be keep away from strong shaking during any transportation or
movement.
· Don’t pull up the light by only the head, or it might cause damages to the
mechanical parts.
· Don’t expose the fixture in overheat, moisture or environment with too much dust
when installing it. And don’t lay any power cables on the floor. Or it might cause
electronic shock to the people.
· Make sure the installation place is in good safety condition before installing the
fixture.
· Make sure to put the safety chain and check whether the screws are screwed
properly when installing the fixture.
· Make sure the lens are in good condition. It’s recommended to replace the units if
there are any damages or severe scratch.
· Make sure the fixture is operated by qualified personnel who knows the fixture
before using.
· Keep the original packages if any second shipment is needed.
· Don’t try to change the fixtures without any instruction by the manufacturer or
the appointed repairing agencies.
· It is not in warranty range if there are any malfunctions from not following the
user manual to operate or any illegal operation, like shock short circuit, electronic
shock, lamp broke, etc.
from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture
is kept at least 0.5m (1.5 ft) away from any flammable materials (decoration etc.).
6
Always use and install the supplied safety cable as a safety measure to prevent
accidental damage and/or injury in the event the clamp fails.
Mounting points: Overhead mounting requires extensive experience, including
amongst others calculating working load limits, a fine knowledge of the installation
material being used, and periodic safety inspection of all installation material and the
fixture. If you lack these qualifications, do not attempt the installation yourself.
Improper installation can result in bodily injury.
Be sure to complete all rigging and installation procedures before connecting the
main power cord to the appropriate wall outlet.
Clamp Mounting: The JNR ELLIPSOIDAL 200ZD provides a unique mounting bracket
assembly, and the safety cable rigging point in one unit (see the illustration below).
When mounting this fixture to truss be sure to secure an appropriately rated clamp to
the handle using a M10 screw fitted through the center hole of the handle. As an
added safety measure be sure to attached at least one properly rated safety cable to
the fixture using on of the safety cable rigging point.
Satety Clamp
5 INSTALLATIONS
Safety Cable
Truss installing
Cautions: For added protection mount the fixtures in areas outside walking paths,
seating areas, or in areas were the fixture might be reached by unauthorized personnel.
Before mounting the fixture to any surface, make sure that the installation area can
hold a minimum point load of 10 times the device’s weight.
Fixture installation must always be secured with a secondary safety attachment, such
as an appropriate safety cable.
Never stand directly below the device when mounting, removing, or servicing the fixture.
.05.
Floor projection
.06.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement