Extech Instruments 480172 AC Line Splitter User's Manual

Add to my manuals
1 Pages

advertisement

Extech Instruments 480172 AC Line Splitter User's Manual | Manualzz
AC Line Splitter ‐ Model 480172
Operation
Specifications
The Line Splitter provides a means to cleanly “open” a standard 120V AC line cord in order to
make clamp type current measurements. When connected between the 120V AC wall outlet
and the device under test, a clamp meter can then be clamped around one of the two test
openings in the Splitter. One opening provides a one‐to‐one current reading and the other
provides a times‐ten (X10) reading so that small current will display with better resolution on a
clamp meter.
Voltage
Current
Temperature
Humidity
Altitude
Dimensions:
Weight
Safety
120V +/‐10%
15Amps max
Operating; 41ºF to 104ºF (5ºC to 40ºC)
Storage; ‐4ºF to 140ºF (‐20ºC to 60ºC)
Operating; Max 80% up to 87ºF (31ºC) decreasing linearly to 50% at 104ºF
(40ºC), Storage; <80%
Operating; 7000ft. (2000) meters maximum.
5.25 x 2 x 1” (133 x 51 x 25mm)
0.753lb (342g) (includes holster).
For indoor use and in accordance with the requirements for double insulation to
IEC1010‐1 (1995): EN61010‐1 (1995) Overvoltage Category II, Pollution Degree
2.
International Safety Symbols
Current Measurements
1. Plug the AC Line Splitter into the 120V receptacle
2. Plug the line cord from the load into the AC Line Splitter socket
3. Close the Clamp‐on jaws around either the X1 or X10 arm of the AC Line Splitter
4. If the X1 position is used, read the current directly on the meter
5. If the X10 position is used, divide the meter reading by 10 to obtain the actual current
Voltage Measurements
1. Plug the AC Line Splitter into the 120V receptacle
2. Insert the multimeter test leads into the two Voltage Test jacks
Refer to the manual for further information
Double insulation
Copyright © 2014 FLIR Systems, Inc.
All rights reserved including the right of reproduction in whole or in part in any form
www.extech.com
3. Read the voltage on the multimeter.
Extech model 480172 v1.1 4/14

advertisement

Was this manual useful for you? Yes No