CONTROL PANEL OPERATION The control pane l keypad will look like the following Fig.1: HIGH MED LOW FAN COOL HEAT POWER Fig.1 POWER - Press the POW ER button to turn the unit on or off. W hen the unit is on,the power indicator light will be green.When the unit is off,the light will go out. MODE - Push this button to cycle through the modes from COOL-HEAT-FAN-COOL.The indicator light beside the "M ODE" option will illuminate, identifying the mode selected. - COO L:The rang e of set temperature is 17 OC/62 OF O O ~30 C/86 F.Cooling beg ins au tom atically when the room temperature is above the set point,and stops when the room temperature is 2 OC(4 O F) below the set point.But the comp ressor will run 5 m inutes at least in COOL m ode before stoping. The fan runs in continu ous mode. - HEAT:The range of set temperature is 17 OC/62OF O O ~29 C/84 F.For hea t pump models,the unit can alternate to run between in reverse cycle heat mode and electric heater mode according to the difference between the setting temperature and the room tempe rature.The fan motor cycles on and off with the compressor and electric hea ter. NOTE: The reverse cycle and electric he ater can not be run at the same time. - FAN:Fan ope ration only without heating and cooling. UP/DOWN BUTTONS ( / ) - Push the UP (or DOWN) button to increase (or decrease) the set temperature of the unit in cooling or heating mode.The temperature can be set by O O increments of 1 C (1 F).The setting temperature appea rs in the display. NOTE:Press and ho ld and buttons toge ther for 3 seconds will alternate the tempe rature display O O between C & F scale. FAN (FAN SPEED) - Every time you push this button,the fan speed cycles through the settings as follows:HIGH-M EDLOW -HIGH. DISPLAYS: O O - Shows the set tem perature in C or F. While on Fan only m ode ,it shows the room temperature. Control code (on some models): LC-Pads on the control panel is not available.The unit can be setted by using wire cotroller only. Error codes: AS-Room temp erature sensor error; ES-Evapo rator temperature sensor error; CS-Condenser temperature sensor error; OS-Outside tempe rature sensor error; HS-Exhaust tempe rature sen sor error; NOTE:Whe n error occurs,unplug the unit and plug it back in.If error repe ats, call for service. Other codes: LO-Room tem perature is lower than 0 OC/32 OF; O O HI-Room temperature is higher than 37 C/99 F.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project