Fujitsu AUGD24GATH Operation Manual

Fujitsu AUGD24GATH Operation Manual
‫ﺩﻟﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ‬
‫ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ]ﺍﻟﻧﻭﻉ ﺍﻟﺷﺭﻳﻁﻲ )ﻋﻠﻰ ﺷﻛﻝ ﻋﻠﺑﺔ([‬
‫ﺍﺣﺗﻔﻅ ﺑﻬﺫﺍ ﺍﻟﺩﻟﻳﻝ ﻟﻠﺭﺟﻭﻉ ﺇﻟﻳﻪ ﻓﻲ ﺍﻟﻣﺳﺗﻘﺑﻝ‪.‬‬
‫‪AUGB07GATH‬‬
‫‪AUGB09GATH‬‬
‫‪AUGB12GATH‬‬
‫‪AUGB14GATH‬‬
‫‪AUGB18GATH‬‬
‫‪AUGB24GATH‬‬
‫‪AUGD18GATH‬‬
‫‪AUGD24GATH‬‬
‫‪AUGA30GATH‬‬
‫‪AUGA36GATH‬‬
‫‪AUGA45GATH‬‬
‫‪AUGA54GATH‬‬
‫ﺭﺍﺟﻊ ﻣﻠﺻﻕ ﺍﻟﺗﻘﻧﻳﻥ ﻟﻣﻌﺭﻓﺔ ﺍﻟﺭﻗﻡ ﺍﻟﻣﺳﻠﺳﻝ ﻭﻋﺎﻡ ﻭﺷﻬﺭ ﺍﻟﺗﺻﻧﻳﻊ‪.‬‬
‫ﺻﻧﻊ ﻓﻲ ﺗﺎﻳﻼﻧﺩ‬
‫ﺭﻗﻡ ﺍﻟﺻﻧﻑ ‪9369313240‬‬
‫‪6/23/2017 3:33:17 PM‬‬
‫‪1‬‬
‫‪9369313240_OM_AR.indd‬‬
‫ﺩﻟﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ‬
‫ﺭﻗﻡ ﺍﻟﺻﻧﻑ ‪9369313240‬‬
‫ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻓﻲ ﻧﻅﺎﻡ ‪) VRF‬ﺍﻟﻧﻭﻉ ﺍﻟﺷﺭﻳﻁﻲ(‬
‫ﺍﻟﻣﺣﺗﻭﻳﺎﺕ‬
‫ﺍﺣﺗﻳﺎﻁﺎﺕ ﺍﻟﺳﻼﻣﺔ ‪1 ............................................................................................‬‬
‫ﺃﺳﻣﺎء ﺍﻷﺟﺯﺍء ‪1 ................................................................................................‬‬
‫ﺍﻟﺗﺷﻐﻳﻝ ‪) MANUAL AUTO‬ﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ(‪2 .............................................................‬‬
‫ﺿﺑﻁ ﺍﺗﺟﺎﻩ ﺗﺩﻭﻳﺭ ﺍﻟﻬﻭﺍء‪2 .....................................................................................‬‬
‫ﺗﻠﻣﻳﺣﺎﺕ ﺍﻟﺗﺷﻐﻳﻝ‪2 ..............................................................................................‬‬
‫ﺍﻟﺗﻧﻅﻳﻑ ﻭﺍﻟﻌﻧﺎﻳﺔ‪2 ..............................................................................................‬‬
‫ﺍﺳﺗﻛﺷﺎﻑ ﺍﻷﻋﻁﺎﻝ ﻭﺇﺻﻼﺣﻬﺎ‪3 ...............................................................................‬‬
‫ﺍﻟﻣﻭﺍﺻﻔﺎﺕ‪4 ....................................................................................................‬‬
‫ﺍﺣﺗﻳﺎﻁﺎﺕ ﺍﻟﺳﻼﻣﺔ‬
‫● ﻗﺑﻝ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﺟﻬﺎﺯ‪ ،‬ﺍﻗﺭﺃ ﻫﺫﻩ "ﺍﻻﺣﺗﻳﺎﻁﺎﺕ" ﺑﺎﻟﻛﺎﻣﻝ ﻭﻗﻡ ﺑﺗﺷﻐﻳﻝ ﺍﻟﺟﻬﺎﺯ ﺑﺎﻟﻁﺭﻳﻘﺔ ﺍﻟﺻﺣﻳﺣﺔ‪.‬‬
‫● ﺍﻟﺗﻌﻠﻳﻣﺎﺕ ﺍﻟﻭﺍﺭﺩﺓ ﻓﻲ ﻫﺫﺍ ﺍﻟﻘﺳﻡ ﺗﺭﺗﺑﻁ ﺟﻣﻳﻌًﺎ ﺑﺎﻟﺳﻼﻣﺔ؛ ﺗﺄﻛﺩ ﻣﻥ ﺍﻟﺣﻔﺎﻅ ﻋﻠﻰ ﻅﺭﻭﻑ ﺍﻟﺗﺷﻐﻳﻝ ﺍﻵﻣﻧﺔ‪.‬‬
‫● ﺗﺷﻳﺭ ﻋﺑﺎﺭﺗﻲ "ﺗﺣﺫﻳﺭ" ﻭ"ﺗﻧﺑﻳﻪ" ﻓﻲ ﻫﺫﻩ ﺍﻟﺗﻌﻠﻳﻣﺎﺕ ﺇﻟﻰ ﺍﻟﻣﻌﺎﻧﻲ ﺍﻟﺗﺎﻟﻳﺔ‪:‬‬
‫ﺗﺣﺫﻳﺭ‬
‫ﺗﺷﻳﺭ ﻫﺫﻩ ﺍﻟﻌﻼﻣﺔ ﺇﻟﻰ ﺍﻹﺟﺭﺍءﺍﺕ‪ ،‬ﺍﻟﺗﻲ ﻓﻲ ﺣﺎﻟﺔ ﺗﻧﻔﻳﺫﻫﺎ ﺑﺷﻛﻝ ﻏﻳﺭ‬
‫ﺻﺣﻳﺢ‪ ،‬ﻗﺩ ﺗﺅﺩﻱ ﺇﻟﻰ ﺍﻟﻭﻓﺎﺓ ﺃﻭ ﺍﻹﺻﺎﺑﺔ ﺍﻟﺧﻁﻳﺭﺓ ﻟﻠﻣﺳﺗﺧﺩﻡ‪.‬‬
‫ﺗﻧﺑﻳﻪ‬
‫ﺗﺷﻳﺭ ﻫﺫﻩ ﺍﻟﻌﻼﻣﺔ ﺇﻟﻰ ﺍﻹﺟﺭﺍءﺍﺕ‪ ،‬ﺍﻟﺗﻲ ﻓﻲ ﺣﺎﻟﺔ ﻋﺩﻡ ﺗﻧﻔﻳﺫﻫﺎ ﺑﺷﻛﻝ‬
‫ﺻﺣﻳﺢ‪ ،‬ﻗﺩ ﺗﺅﺩﻱ ﺿﺭﺭ ﺷﺧﺻﻲ ﻟﻠﻣﺳﺗﺧﺩﻡ ﺃﻭ ﺗﻠﻑ ﻓﻲ ﺍﻟﻣﻣﺗﻠﻛﺎﺕ‪.‬‬
‫ﺍﺣﺗﻳﺎﻁﺎﺕ ﻋﻧﺩ ﺍﻻﺳﺗﺧﺩﺍﻡ‬
‫ﺗﺣﺫﻳﺭ‬
‫● ﻻ ﺗﻌﺭﺽ ﻧﻔﺳﻙ ﻟﺗﻳﺎﺭ ﻫﻭﺍء ﻣﺑﺎﺷﺭ ﻣﻥ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻟﻔﺗﺭﺓ ﻁﻭﻳﻠﺔ‪.‬‬
‫● ﺗﺟﻧﺏ ﺇﺩﺧﺎﻝ ﺍﻷﺻﺎﺑﻊ ﺃﻭ ﺍﻷﺟﺳﺎﻡ ﻓﻲ ﻣﻧﻔﺫ ﺍﻹﺧﺭﺍﺝ ﺃﻭ ﺷﺑﻛﺎﺕ ﺍﻻﻣﺗﺻﺎﺹ‪.‬‬
‫● ﺑﺎﺳﺗﺛﻧﺎء ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﻁﻭﺍﺭﺉ‪ ،‬ﺗﺟﻧﺏ ﻣﻁﻠ ًﻘﺎ ﻓﺻﻝ ﺍﻟﺗﻳﺎﺭ ﺍﻟﺭﺋﻳﺳﻲ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﻗﺎﻁﻊ ﺍﻟﺗﻳﺎﺭ ﺍﻟﻔﺭﻋﻲ‬
‫ﻟﻠﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺃﺛﻧﺎء ﺍﻟﺗﺷﻐﻳﻝ‪ .‬ﺳﻭﻑ ﻳﺅﺩﻱ ﺫﻟﻙ ﺇﻟﻰ ﺗﻌﻁﻝ ﺍﻟﺿﺎﻏﻁ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺗﺳﺭﻳﺏ ﺍﻟﻣﻳﺎﻩ‪ .‬ﻗﻡ‬
‫ﺃﻭﻻ ﺑﺈﻳﻘﺎﻑ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻣﻥ ﺧﻼﻝ ﺗﺷﻐﻳﻝ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﺃﻭ ﺍﻟﻣﺣﻭﻝ ﺃﻭ ﺟﻬﺎﺯ ﺍﻹﺩﺧﺎﻝ ﺍﻟﺧﺎﺭﺟﻲ ﺛﻡ ﻗﻡ‬
‫ﺑﻔﺻﻝ ﺍﻟﻘﺎﻁﻊ‪ .‬ﺗﺄﻛﺩ ﻣﻥ ﺍﻟﺗﺷﻐﻳﻝ ﻣﻥ ﺧﻼﻝ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﺃﻭ ﺍﻟﻣﺣﻭﻝ ﺃﻭ ﺟﻬﺎﺯ ﺍﻹﺩﺧﺎﻝ ﺍﻟﺧﺎﺭﺟﻲ‪.‬‬
‫● ﻓﻲ ﺣﺎﻟﺔ ﺗﻠﻑ ﺳﻠﻙ ﻣﺻﺩﺭ ﺍﻟﻁﺎﻗﺔ ﻟﻬﺫﺍ ﺍﻟﺟﻬﺎﺯ‪ ،‬ﻓﻼ ﻳﺟﺏ ﺍﺳﺗﺑﺩﺍﻟﻪ ﺇﻻ ﺑﻭﺍﺳﻁﺔ ﻣﻭﻅﻑ ﺻﻳﺎﻧﺔ ﻣﻌﺗﻣﺩ‪،‬‬
‫ﻧﻅﺭً ﺍ ﻷﻥ ﻣﻥ ﺍﻟﻼﺯﻡ ﺍﺳﺗﺧﺩﺍﻡ ﺃﺩﻭﺍﺕ ﻷﻏﺭﺍﺽ ﻣﺧﺻﺻﺔ ﻭﺳﻠﻙ ﻣﺧﺻﺹ‪.‬‬
‫● ﻓﻲ ﺣﺎﻟﺔ ﺣﺩﻭﺙ ﺗﺳﺭﻳﺏ ﻟﺳﺎﺋﻝ ﺍﻟﺗﺑﺭﻳﺩ‪ ،‬ﻓﻳﺟﺏ ﺇﻁﻔﺎء ﺃﻱ ﻟﻬﺏ‪ ،‬ﻭﺗﻬﻭﻳﺔ ﺍﻟﻐﺭﻓﺔ ﻭﺍﻻﺗﺻﺎﻝ ﺑﻣﻭﻅﻔﻲ‬
‫ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﻣﻌﺗﻣﺩﻳﻥ‪.‬‬
‫● ﻫﺫﺍ ﺍﻟﺟﻬﺎﺯ ﻏﻳﺭ ﻣﺧﺻﺹ ﻟﻼﺳﺗﺧﺩﺍﻡ ﻣﻥ ﺟﺎﻧﺏ ﺍﻷﺷﺧﺎﺹ ﺍﻟﺫﻳﻥ ﻳﻌﺎﻧﻭﻥ ﻣﻥ ﻧﻘﺹ ﻓﻲ ﺍﻟﻘﺩﺭﺍﺕ ﺍﻟﺑﺩﻧﻳﺔ‬
‫ﺃﻭ ﺍﻟﺷﻌﻭﺭﻳﺔ ﺃﻭ ﺍﻟﺫﻫﻧﻳﺔ )ﺑﻣﺎ ﻓﻳﻬﻡ ﺍﻷﻁﻔﺎﻝ( ﺃﻭ ﻳﻌﺎﻧﻭﻥ ﻣﻥ ﻧﻘﺹ ﺍﻟﺧﺑﺭﺓ ﻭﺍﻟﻣﻌﺭﻓﺔ‪ ،‬ﻣﺎ ﻟﻡ ﻳﺗﻡ ﺍﻹﺷﺭﺍﻑ‬
‫ﻋﻠﻳﻬﻡ ﺃﻭ ﺇﻋﻁﺎﺋﻬﻡ ﺍﻟﺗﻌﻠﻳﻣﺎﺕ ﺍﻟﻣﺗﻌﻠﻘﺔ ﺑﺎﺳﺗﺧﺩﺍﻡ ﺍﻟﺟﻬﺎﺯ ﻣﻥ ﺟﺎﻧﺏ ﺷﺧﺹ ﻣﺳﺅﻭﻝ ﻋﻥ ﺳﻼﻣﺗﻬﻡ‪ .‬ﻳﺟﺏ‬
‫ﺍﻹﺷﺭﺍﻑ ﻋﻠﻰ ﺍﻷﻁﻔﺎﻝ ﻟﻠﺗﺄﻛﺩ ﻣﻥ ﺃﻧﻬﻡ ﻻ ﻳﻌﺑﺛﻭﻥ ﺑﺎﻟﺟﻬﺎﺯ‪.‬‬
‫ﻣﻼﺣﻅﺔ‪:‬‬
‫ﺇﻥ ﺗﺑﺩﻳﻝ ﻭﺿﻊ ﺍﻟﺗﺷﻐﻳﻝ ﻓﻲ ﻧﻅﺎﻡ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺣﺭﺍﺭﺓ ﻗﺩ ﻳﺣﺗﺎﺝ ﺇﻟﻰ ﺑﻌﺽ ﺍﻟﻭﻗﺕ ﻟﻠﺗﺣﺿﻳﺭ ﻟﻠﺗﺷﻐﻳﻝ‪.‬‬
‫ﻟﻠﺗﺷﻐﻳﻝ‪ .‬ﺑﺭﺟﺎء ﻣﻼﺣﻅﺔ ﺃﻥ ﻫﺫﺍ ﻟﻳﺱ ﻋﻁﻼ‪.‬‬
‫ﺍﺣﺗﻳﺎﻁﺎﺕ ﻋﻧﺩ ﺍﻟﺗﺭﻛﻳﺏ‬
‫ﺗﻧﺑﻳﻪ‬
‫● ﻻ ﺗﺣﺎﻭﻝ ﺗﺭﻛﻳﺏ ﺟﻬﺎﺯ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺍﻟﺣﺎﻟﻲ ﺑﻧﻔﺳﻙ‪.‬‬
‫● ﻻ ﺗﺣﺗﻭﻱ ﻫﺫﻩ ﺍﻟﻭﺣﺩﺓ ﻋﻠﻰ ﺃﺟﺯﺍء ﻳﻣﻛﻥ ﺻﻳﺎﻧﺗﻬﺎ ﺑﻭﺍﺳﻁﺔ ﺍﻟﻣﺳﺗﺧﺩﻡ‪ .‬ﺍﺣﺭﺹ ﺩﺍﺋﻣًﺎ ﻋﻠﻰ ﺍﺳﺗﺷﺎﺭﺓ‬
‫ﻣﻭﻅﻔﻲ ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﻣﻌﺗﻣﺩﻳﻥ ﻓﻳﻣﺎ ﻳﺗﻌﻠﻕ ﺑﺄﻱ ﺇﺻﻼﺣﺎﺕ‪.‬‬
‫● ﻋﻧﺩ ﺍﻟﻧﻘﻝ‪ ،‬ﺍﺳﺗﺷﺭ ﻣﻭﻅﻔﻲ ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﻣﻌﺗﻣﺩﻳﻥ ﺑﺷﺄﻥ ﻓﺻﻝ ﺗﻭﺻﻳﻝ ﺍﻟﻭﺣﺩﺓ ﻭﺗﺭﻛﻳﺑﻬﺎ‪.‬‬
‫● ﻳﺟﺏ ﺗﻭﺻﻳﻝ ﺍﻟﻭﺣﺩﺓ ﺑﺎﻷﺭﺽ‪.‬‬
‫● ﺗﺄﻛﺩ ﻣﻥ ﺗﻧﻔﻳﺫ ﺃﻋﻣﺎﻝ ﺍﻟﺻﺭﻑ )ﻣﻭﺍﺳﻳﺭ ﺍﻟﺻﺭﻑ( ﺑﺷﻛﻝ ﺻﺣﻳﺢ ﻣﻥ ﺃﺟﻝ ﺍﻟﺗﺻﺭﻳﻑ‪.‬‬
‫● ﺗﺟﻧﺏ ﺗﺭﻛﻳﺏ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺑﺎﻟﻘﺭﺏ ﻣﻥ ﻣﺻﺩﺭ ﻟﻬﺏ ﺃﻭ ﺟﻬﺎﺯ ﺗﺳﺧﻳﻥ ﺁﺧﺭ‪.‬‬
‫● ﻋﻧﺩ ﺗﺭﻛﻳﺏ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻭﺍﻟﺧﺎﺭﺟﻳﺔ‪ ،‬ﻳﺟﺏ ﺍﺗﺧﺎﺫ ﺍﻻﺣﺗﻳﺎﻁﺎﺕ ﻟﻣﻧﻊ ﻭﺻﻭﻝ ﺍﻷﻁﻔﺎﻝ‪.‬‬
‫ﺃﺳﻣﺎء ﺍﻷﺟﺯﺍء‬
‫‪AUGB 07/09/12/14/18/24‬‬
‫)‪(4‬‬
‫)‪(6‬‬
‫)‪(2‬‬
‫)‪(5‬‬
‫)‪(7‬‬
‫)‪(8‬‬
‫)‪(9‬‬
‫)‪(3‬‬
‫‪AUGD 18/24, AUGA 30/36/45/54‬‬
‫)‪(4‬‬
‫)‪(2‬‬
‫)‪(5‬‬
‫)‪(6‬‬
‫)‪(7‬‬
‫)‪(8‬‬
‫ﺗﻧﺑﻳﻪ‬
‫● ﻻ ﺗﺿﻊ ﺍﻟﺣﻳﻭﺍﻧﺎﺕ ﺃﻭ ﺍﻟﻧﺑﺎﺗﺎﺕ ﻓﻲ ﺍﻟﻣﺳﺎﺭ ﺍﻟﻣﺑﺎﺷﺭ ﻟﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء‪.‬‬
‫● ﻻ ﺗﻭﺟﻪ ﺗﻳﺎﺭ ﺍﻟﻬﻭﺍء ﺇﻟﻰ ﺃﻣﺎﻛﻥ ﺍﻟﻠﻬﺏ ﺃﻭ ﺃﺟﻬﺯﺓ ﺍﻟﺗﺳﺧﻳﻥ‪.‬‬
‫● ﻻ ﺗﻘﻡ ﺑﺳﺩ ﺃﻭ ﺗﻐﻁﻳﺔ ﻣﻧﻔﺫ ﺍﻹﺩﺧﺎﻝ ﺃﻭ ﻣﻧﻔﺫ ﺍﻹﺧﺭﺍﺝ‪.‬‬
‫● ﻻ ﺗﺗﺳﻠﻕ ﻋﻠﻰ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺃﻭ ﺗﺿﻊ ﺍﻷﺷﻳﺎء ﻋﻠﻳﻪ‪.‬‬
‫● ﻻ ﺗﺿﻊ ﺍﻟﺯﻫﺭﻳﺎﺕ ﺃﻭ ﺣﺎﻭﻳﺎﺕ ﺍﻟﻣﻳﺎﻩ ﺃﻋﻠﻰ ﺃﺟﻬﺯﺓ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء‪.‬‬
‫● ﻻ ﺗﻘﻡ ﺑﺗﻌﻠﻳﻕ ﺍﻷﺷﻳﺎء ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ‪.‬‬
‫● ﻻ ﺗﺿﻊ ﺃﻱ ﺷﻲء ﻳﻧﺑﻐﻲ ﻋﺩﻡ ﺗﻌﺭﺿﻪ ﻟﻠﺑﻝ ﺃﺳﻔﻝ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ‪.‬‬
‫● ﺍﺣﺭﺹ ﺩﺍﺋﻣًﺎ ﻋﻠﻰ ﻓﺻﻝ ﺍﻟﻘﺎﻁﻊ ﺍﻟﻛﻬﺭﺑﺎﺋﻲ ﻋﻧﺩ ﺗﻧﻅﻳﻑ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺃﻭ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء‪.‬‬
‫● ﻻ ﺗﻘﻡ ﺑﺳﻛﺏ ﺍﻟﻣﻳﺎﻩ ﺃﻭ ﻣﺣﻠﻭﻝ ﺍﻟﺗﻧﻅﻳﻑ ﻋﻠﻰ ﺍﻟﻭﺣﺩﺓ ﻣﺑﺎﺷﺭﺓ‪ ،‬ﺃﻭ ﻏﺳﻝ ﺍﻟﻭﺣﺩﺓ ﺑﺎﺳﺗﺧﺩﺍﻡ ﻫﺫﻩ ﺍﻟﻣﻭﺍﺩ‪.‬‬
‫● ﺗﺟﻧﺏ ﺗﻌﺭﻳﺽ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻟﻠﻣﺎء ﺑﺷﻛﻝ ﻣﺑﺎﺷﺭ‪.‬‬
‫● ﻻ ﺗﻘﻡ ﺑﺗﺷﻐﻳﻝ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺑﻳﺩﻳﻥ ﻣﺑﺗﻠﺔ‪.‬‬
‫● ﺍﻓﺣﺹ ﺣﺎﻟﺔ ﺣﺎﻣﻝ ﺍﻟﺗﺭﻛﻳﺏ ً‬
‫ﺑﺣﺛﺎ ﻋﻥ ﺗﻠﻑ‪.‬‬
‫● ﻻ ﺗﻘﻡ ﺑﺎﻟﺗﺷﻐﻳﻝ ﺇﻻ ﻣﻊ ﺗﺭﻛﻳﺏ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء‪.‬‬
‫● ﻻ ﺗﺷﺭﺏ ﺍﻟﻣﺎء ﺍﻟﻣﺗﺻﺭﻑ ﻣﻥ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء‪.‬‬
‫● ﻻ ﺗﻌﺭﺽ ﺯﻋﺎﻧﻑ ﺍﻟﻣُﺷﻊ ﻷﻱ ﺿﻐﻁ ﺷﺩﻳﺩ‪.‬‬
‫● ﻻ ﺗﺳﺗﺧﺩﻡ ﻏﺎﺯﺍﺕ ﻗﺎﺑﻠﺔ ﻟﻼﺷﺗﻌﺎﻝ ﺑﺎﻟﻘﺭﺏ ﻣﻥ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء‪.‬‬
‫● ﻻ ﺗﻠﻣﺱ ﺍﻟﻣﻭﺍﺳﻳﺭ ﺃﺛﻧﺎء ﺍﻟﺗﺷﻐﻳﻝ‪.‬‬
‫● ﺗﺄﻛﺩ ﻣﻥ ﺇﺑﻌﺎﺩ ﺃﻱ ﺃﺟﻬﺯﺓ ﻛﻬﺭﺑﺎﺋﻳﺔ ﻋﻥ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺃﻭ ﺍﻟﺧﺎﺭﺟﻳﺔ ﺑﻣﻘﺩﺍﺭ ‪ 1‬ﻣﺗﺭ ﻋﻠﻰ ﺍﻷﻗﻝ‪.‬‬
‫)‪(1‬‬
‫)‪(9‬‬
‫)‪(3‬‬
‫)‪(1‬‬
‫)‪ (1‬ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء‬
‫)‪ (2‬ﺃﻟﺳﻧﺔ ﺍﺗﺟﺎﻩ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء‬
‫)‪ (3‬ﺷﺑﻛﺔ ﺍﻣﺗﺻﺎﺹ ﺍﻟﻬﻭﺍء‬
‫)‪ (4‬ﺗﺷﻐﻳﻝ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻭﻣﺻﺎﺑﻳﺢ ﺍﻟﻣﺅﺷﺭﺍﺕ‬
‫ً‬
‫ﻣﺗﺳﺧﺎ‪ .‬ﻗﻡ ﺑﺗﻧﻅﻳﻑ ﺍﻟﻣﺭﺷﺢ ﻣﻥ‬
‫)‪ (5‬ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺭﺷﺢ )ﺍﻷﺣﻣﺭ(‪ :‬ﻳﺿﻲء ﻋﻧﺩﻣﺎ ﻳﺻﺑﺢ ﺍﻟﻣﺭﺷﺢ‬
‫ﺧﻼﻝ ﺍﻟﺭﺟﻭﻉ ﺇﻟﻰ ﻗﺳﻡ "ﺍﻟﺗﻧﻅﻳﻑ ﻭﺍﻟﻌﻧﺎﻳﺔ"‪ .‬ﻳﻧﻁﻔﺊ ﻋﻧﺩ ﺿﻐﻁ ﺯﺭ ‪) RESET‬ﺇﻋﺎﺩﺓ ﺗﻌﻳﻳﻥ( ﺑﻌﺩ‬
‫ﺍﻟﺗﻧﻅﻳﻑ‪.‬‬
‫)‪ (6‬ﻣﺅﺷﺭ ﻣﺻﺑﺎﺡ ﺍﻟﻣﺅﻗﺕ )ﺍﻟﺑﺭﺗﻘﺎﻟﻲ(‪ :‬ﻳﺿﻲء ﻋﻧﺩﻣﺎ ﻳﻛﻭﻥ ﺍﻟﻣﺅﻗﺕ ﻗﻳﺩ ﺍﻟﺗﺷﻐﻳﻝ‪.‬‬
‫)‪ (7‬ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ(‪ :‬ﻳﺿﻲء ﺃﺛﻧﺎء ﺍﻟﺗﺷﻐﻳﻝ‪.‬‬
‫)‪ (8‬ﻣﺳﺗﻘﺑﻝ ﺇﺷﺎﺭﺓ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ‪ :‬ﻫﺫﺍ ﻫﻭ ﻣﻛﺎﻥ ﺍﺳﺗﻘﺑﺎﻝ ﺍﻹﺷﺎﺭﺍﺕ ﻣﻥ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ‪.‬‬
‫)‪ (9‬ﺯﺭ ‪) MANUAL AUTO‬ﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ(‪ :‬ﻳُﺳﺗﺧﺩﻡ ﻫﺫﺍ ﺍﻟﺯﺭ ﻟﺗﺷﻐﻳﻝ ﺍﻟﺟﻬﺎﺯ ﻓﻲ ﺣﺎﻟﺔ ﻋﺩﻡ ﺗﻭﺍﻓﺭ‬
‫ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ‪.‬‬
‫ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ )ﺍﺧﺗﻳﺎﺭﻱ(‬
‫ﺃﻧﻭﺍﻉ ﻭﺣﺩﺍﺕ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ‪:‬‬
‫● ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﻼﺳﻠﻛﻳﺔ‬
‫● ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺳﻠﻛﻳﺔ‬
‫● ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺑﺳﻳﻁﺔ‬
‫ﻟﻠﺗﻌﺭﻑ ﻋﻠﻰ ﻁﺭﻳﻘﺔ ﺍﻟﺗﺷﻐﻳﻝ‪ ،‬ﻳﺭﺟﻰ ﺍﻟﺭﺟﻭﻉ ﺇﻟﻰ ﺩﻟﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ ﻟﻛﻝ ﺟﻬﺎﺯ‪.‬‬
‫‪Ar-1‬‬
‫‪5/15/2017 14:34:10‬‬
‫‪9369313240_OM_AR.indd 1‬‬
‫ﺍﻟﺗﺷﻐﻳﻝ ‪) MANUAL AUTO‬ﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ(‬
‫ﺍﺳﺗﺧﺩﻡ ﺍﻟﺗﺷﻐﻳﻝ ‪) MANUAL AUTO‬ﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( ﻓﻲ ﺣﺎﻟﺔ ﻓﻘﺩ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺃﻭ ﺃﺻﺑﺣﺕ‬
‫ﻏﻳﺭ ﻣﺗﻭﺍﻓﺭﺓ ﺑﺷﻛﻝ ﺁﺧﺭ‪.‬‬
‫ﺃﺩﺍء ﺍﻟﺗﺩﻓﺋﺔ‬
‫● ﻳﻌﻣﻝ ﻭﺿﻊ ﺍﻟﺗﺩﻓﺋﺔ ﺑﻣﺑﺩﺃ ﻣﺿﺧﺔ ﺍﻟﺣﺭﺍﺭﺓ‪ ،‬ﺣﻳﺙ ﻳﺗﻡ ﺍﻣﺗﺻﺎﺹ ﺍﻟﺣﺭﺍﺭﺓ ﻣﻥ ﺍﻟﻬﻭﺍء ﻓﻲ ﺍﻟﺧﺎﺭﺝ ﻭﻧﻘﻝ‬
‫ﺗﻠﻙ ﺍﻟﺣﺭﺍﺭﺓ ﺇﻟﻰ ﺍﻟﺩﺍﺧﻝ‪ .‬ﻧﺗﻳﺟﺔ ﻟﺫﻟﻙ‪ ،‬ﻳﻘﻝ ﺃﺩﺍء ﺍﻟﺗﺷﻐﻳﻝ ﻣﻊ ﺍﻧﺧﻔﺎﺽ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻓﻲ ﺍﻟﺧﺎﺭﺝ‪ .‬ﺇﺫﺍ‬
‫ﺷﻌﺭﺕ ﺃﻥ ﺃﺩﺍء ﺍﻟﺗﺩﻓﺋﺔ ﺍﻟﻧﺎﺗﺞ ﻏﻳﺭ ﻛﺎﻑٍ‪ ،‬ﻋﻧﺩﺋﺫ ﻳﻭﺻﻰ ﺑﺎﺳﺗﺧﺩﺍﻡ ﺟﻬﺎﺯ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺍﻟﺣﺎﻟﻲ ﻣﻊ ﻧﻭﻉ‬
‫ﺁﺧﺭ ﻣﻥ ﺃﺟﻬﺯﺓ ﺍﻟﺗﺩﻓﺋﺔ‪.‬‬
‫● ﻳﻘﻭﻡ ﻭﺿﻊ ﺍﻟﺗﺩﻓﺋﺔ ﺑﺗﺩﻓﺋﺔ ﺍﻟﻐﺭﻓﺔ ﺑﺎﻟﻛﺎﻣﻝ ﻣﻥ ﺧﻼﻝ ﺇﻋﺎﺩﺓ ﺗﺩﻭﻳﺭ ﺍﻟﻬﻭﺍء ﻓﻲ ﻛﺎﻓﺔ ﺃﺭﺟﺎء ﺍﻟﻐﺭﻓﺔ‪ ،‬ﺣﻳﺙ ﻳﺗﻡ‬
‫ﺍﻟﺣﺻﻭﻝ ﻋﻠﻰ ﺍﻟﻧﺗﻳﺟﺔ ﻓﻲ ﺑﻌﺽ ﺍﻷﺣﻳﺎﻥ ﺑﻌﺩ ﺑﺩء ﺗﺷﻐﻳﻝ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺃﻭﻻ ﺣﺗﻰ ﺗﺗﻡ ﺗﺩﻓﺋﺔ ﺍﻟﻐﺭﻓﺔ‪.‬‬
‫ﺗﻧﺑﻳﻪ‬
‫ﻻ ﺗﺿﻐﻁ ﺯﺭ ‪) MANUAL AUTO‬ﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( ﺑﺄﻳﺩﻱ ﻣﺑﺗﻠﺔ ﺃﻭ ﺃﺟﺳﺎﻡ ﻣﺩﺑﺑﺔ‪ ،‬ﻓﻲ ﺣﺎﻟﺔ ﻋﺩﻡ ﻣﺭﺍﻋﺎﺓ‬
‫ﺫﻟﻙ ﻗﺩ ﺗﺣﺩﺙ ﺻﺩﻣﺔ ﻛﻬﺭﺑﺎﺋﻳﺔ ﺃﻭ ﺗﻌﻁﻝ‪.‬‬
‫ﺑﺩء ﺍﻟﺗﺷﻐﻳﻝ‬
‫ﺍﺿﻐﻁ ﺯﺭ ‪) MANUAL AUTO‬ﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( ﻋﻠﻰ ﻟﻭﺣﺔ ﺍﻟﺗﺣﻛﻡ ﻓﻲ ﺍﻟﺗﺷﻐﻳﻝ‪.‬‬
‫ﻳﻣﻛﻥ ﺿﺑﻁ ﺍﻟﺗﺷﻐﻳﻝ ﺣﺳﺏ ﺍﻹﻋﺩﺍﺩ ﺍﻟﺗﺎﻟﻲ‪.‬‬
‫‪) AUTO‬ﺗﻠﻘﺎﺋﻲ(‪:‬‬
‫ﻭﺿﻊ ﺍﻟﺗﺷﻐﻳﻝ‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺗﻌﺫﺭ ﺗﺣﺩﻳﺩ ﺍﻟﻭﺿﻊ ﺍﻟﺗﻠﻘﺎﺋﻲ‪ ،‬ﻓﺈﻧﻪ ﻳﻌﻣﻝ ﺑﻧﻔﺱ ﻭﺿﻊ‬
‫ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺍﻷﺧﺭﻯ ﻋﻠﻰ ﻧﻔﺱ ﺍﻟﻧﻅﺎﻡ‪) .‬ﻭﺇﺫﺍ ﻛﺎﻧﺕ ﺍﻟﻭﺣﺩﺓ‬
‫ﺍﻟﺩﺍﺧﻠﻳﺔ ﺍﻷﺧﺭﻯ ﻋﻠﻰ ﻧﻔﺱ ﺍﻟﻧﻅﺎﻡ ﻻ ﺗﻌﻣﻝ‪ ،‬ﺳﻭﻑ ﻳﻌﻣﻝ ﺗﻛﻳﻳﻑ‬
‫ﺍﻟﻬﻭﺍء ﻋﻠﻰ ﻭﺿﻊ ﺍﻟﺗﺑﺭﻳﺩ‪(.‬‬
‫‪) Fan Speed‬ﺳﺭﻋﺔ ﺍﻟﻣﺭﻭﺣﺔ( ‪) AUTO‬ﺗﻠﻘﺎﺋﻲ(‬
‫‪ 23‬ﺩﺭﺟﺔ ﻣﺋﻭﻳﺔ‬
‫ﺇﻋﺩﺍﺩ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ‬
‫ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ ﺑﻭﺍﺳﻁﺔ ﻛﻣﺑﻳﻭﺗﺭ ﺻﻐﻳﺭ‬
‫● ﻋﻧﺩ ﺍﺳﺗﺧﺩﺍﻡ ﻭﺿﻊ ﺍﻟﺗﺩﻓﺋﺔ ﻓﻲ ﻅﺭﻭﻑ ﺍﻧﺧﻔﺎﺽ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺍﻟﻬﻭﺍء ﻓﻲ ﺍﻟﺧﺎﺭﺝ ﻭﺍﺭﺗﻔﺎﻉ ﺍﻟﺭﻁﻭﺑﺔ‪ ،‬ﻗﺩ‬
‫ﻳﺗﻛﻭﻥ ﺻﻘﻳﻊ ﻋﻠﻰ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ‪ ،‬ﻣﻣﺎ ﻳﺅﺩﻱ ﺇﻟﻰ ﺗﻘﻠﻳﻝ ﺃﺩﺍء ﺍﻟﺗﺷﻐﻳﻝ‪ .‬ﻭﻣﻥ ﺃﺟﻝ ﺗﻔﺎﺩﻱ ﻫﺫﺍ ﺍﻟﻧﻭﻉ ﻣﻥ‬
‫ﺍﻷﺩﺍء ﺍﻟﻣﻧﺧﻔﺽ‪ ،‬ﻳﺗﻡ ﺗﺯﻭﻳﺩ ﻫﺫﻩ ﺍﻟﻭﺣﺩﺓ ﺑﻭﻅﻳﻔﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ ﻭﺍﻟﺗﻲ ﻳﺗﻡ ﺍﻟﺗﺣﻛﻡ ﻓﻳﻬﺎ ﺑﻭﺍﺳﻁﺔ‬
‫ﻛﻣﺑﻳﻭﺗﺭ ﺻﻐﻳﺭ‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﺗﻛﻭﻥ ﺍﻟﺻﻘﻳﻊ‪ ،‬ﻳﺗﻭﻗﻑ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻋﻥ ﺍﻟﻌﻣﻝ ﻣﺅﻗ ًﺗﺎ‪ ،‬ﻭﻳﺗﻡ ﺗﺷﻐﻳﻝ ﺩﺍﺋﺭﺓ‬
‫ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﻟﻔﺗﺭﺓ ﻭﺟﻳﺯﺓ )ﺣﻭﺍﻟﻲ ‪ 4‬ﺇﻟﻰ ‪ 15‬ﺩﻗﻳﻘﺔ(‪.‬‬
‫ﺃﺛﻧﺎء ﺗﺷﻐﻳﻝ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺍﻷﻭﺗﻭﻣﺎﺗﻳﻛﻲ‪ ،‬ﻳﻭﻣﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ(‪.‬‬
‫ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ‬
‫● ﻳﺗﻡ ﺑﺻﻔﺔ ﺩﻭﺭﻳﺔ ﺗﻧﻔﻳﺫ ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ ﻣﻥ ﺃﺟﻝ ﺇﻋﺎﺩﺓ ﺯﻳﺕ ﺍﻟﺿﺎﻏﻁ ﺇﻟﻰ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ‪.‬‬
‫ﻭﺧﻼﻝ ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ‪ ،‬ﻳﻭﻣﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( )ﻟﻣﺩﺓ ‪ 10‬ﺩﻗﺎﺋﻕ ﺗﻘﺭﻳﺑًﺎ(‪.‬‬
‫ﻣﺩﻯ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻭﺍﻟﺭﻁﻭﺑﺔ‬
‫● ﻳﺗﻡ ﺗﻭﺿﻳﺢ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻭﺍﻟﺭﻁﻭﺑﺔ ﺍﻟﻣﻁﻠﻭﺑﺔ ﻟﺗﺷﻐﻳﻝ ﻫﺫﺍ ﺍﻟﻣﻧﺗﺞ ﻓﻲ ﺍﻟﺟﺩﻭﻝ ﺍﻟﺗﺎﻟﻲ‪.‬‬
‫ﺇﻳﻘﺎﻑ ﺍﻟﺗﺷﻐﻳﻝ‬
‫ﻭﺿﻊ ﺑﺎﺭﺩ‪/‬ﺟﺎﻑ‬
‫ﺍﺿﻐﻁ ﺯﺭ ‪) MANUAL AUTO‬ﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( ﻋﻠﻰ ﻟﻭﺣﺔ ﺍﻟﺗﺣﻛﻡ ﻓﻲ ﺍﻟﺗﺷﻐﻳﻝ‪.‬‬
‫ﺿﺑﻁ ﺍﺗﺟﺎﻩ ﺗﺩﻭﻳﺭ ﺍﻟﻬﻭﺍء‬
‫ﻳﻣﻛﻥ ﺍﻟﺗﺣﻛﻡ ﻓﻲ ﺍﻻﺗﺟﺎﻩ ﺍﻟﺭﺃﺳﻲ ﻟﻠﻬﻭﺍء ﻣﻥ ﺧﻼﻝ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ‪.‬‬
‫ﺍﻻﺗﺟﺎﻩ ﺍﻟﺭﺃﺳﻲ‬
‫ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻓﻲ ﺍﻟﺧﺎﺭﺝ‬
‫ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻓﻲ ﺍﻟﺩﺍﺧﻝ‬
‫ﺍﻟﺭﻁﻭﺑﺔ ﻓﻲ ﺍﻟﺩﺍﺧﻝ‬
‫ﻭﺿﻊ ﺍﻟﺗﺩﻓﺋﺔ‬
‫ﻳﺭﺟﻰ ﺍﻟﺭﺟﻭﻉ ﺇﻟﻰ ﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺧﺎﺭﺟﻳﺔ‪.‬‬
‫‪ 18‬ﺇﻟﻰ ‪ 32‬ﺩﺭﺟﺔ ﻣﺋﻭﻳﺔ ‪DB‬‬
‫‪ 10‬ﺇﻟﻰ ‪ 30‬ﺩﺭﺟﺔ ﻣﺋﻭﻳﺔ ‪DB‬‬
‫ﺣﻭﺍﻟﻲ ‪ 80%‬ﺃﻭ ﺃﻗﻝ‬
‫● ﻓﻲ ﺣﺎﻟﺔ ﺗﺷﻐﻳﻝ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻓﻲ ﻅﺭﻭﻑ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺃﻋﻠﻰ ﻣﻥ ﺗﻠﻙ ﺍﻟﻣﺑﻳﻧﺔ‪ ،‬ﻳﺗﻡ ﺗﺷﻐﻳﻝ ﺩﺍﺋﺭﺓ ﺍﻟﺣﻣﺎﻳﺔ‬
‫ﺍﻟﻣﺿﻣﻧﺔ ﻟﻣﻧﻊ ﺗﻠﻑ ﺍﻟﺩﺍﺋﺭﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ‪ .‬ﺃﻳﺿًﺎ ﻓﻲ ﻭﺿﻊ ﺑﺎﺭﺩ ﻭﻭﺿﻊ ﺟﺎﻑ‪ ،‬ﺇﺫﺍ ﺗﻡ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﻭﺣﺩﺓ ﻓﻲ‬
‫ﻅﺭﻭﻑ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺃﻗﻝ ﻣﻥ ﺗﻠﻙ ﺍﻟﻣﺑﻳﻧﺔ ﺃﻋﻼﻩ‪ ،‬ﻓﻘﺩ ﻳﺗﺟﻣﺩ ﻣﺑﺎﺩﻝ ﺍﻟﺣﺭﺍﺭﺓ‪ ،‬ﻣﻣﺎ ﻳﺅﺩﻱ ﺇﻟﻰ ﺗﺳﺭﻳﺏ ﻣﻳﺎﻩ‬
‫ﻭﺗﻠﻔﻳﺎﺕ ﺃﺧﺭﻯ‪.‬‬
‫● ﺇﺫﺍ ﺗﻡ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﻭﺣﺩﺓ ﻟﻔﺗﺭﺍﺕ ﻁﻭﻳﻠﺔ ﻓﻲ ﻅﺭﻭﻑ ﻣﺭﺗﻔﻌﺔ ﺍﻟﺭﻁﻭﺑﺔ‪ ،‬ﻓﻘﺩ ﻳﺣﺩﺙ ﺗﻛﺛﻑ ﻋﻠﻰ ﺳﻁﺢ ﺍﻟﻭﺣﺩﺓ‬
‫ﺍﻟﺩﺍﺧﻠﻳﺔ‪ ،‬ﻭﺗﺗﺳﺎﻗﻁ ﺍﻟﻣﻳﺎﻩ ﺍﻟﻣﺗﻛﺛﻔﺔ ﻋﻠﻰ ﺍﻷﺭﺽ ﺃﻭ ﻋﻠﻰ ﺍﻷﺷﻳﺎء ﺍﻷﺧﺭﻯ ﺗﺣﺕ ﺍﻟﻭﺣﺩﺓ‪.‬‬
‫● ﻻ ﺗﺳﺗﺧﺩﻡ ﻫﺫﻩ ﺍﻟﻭﺣﺩﺓ ﻓﻲ ﺃﻱ ﻏﺭﺽ ﺧﻼﻑ ﺍﻟﺗﺑﺭﻳﺩ ﻭﺍﻟﺗﺩﻓﺋﺔ ﻭﺍﻟﺗﺭﻁﻳﺏ ﻭﺗﺩﻭﻳﺭ ﻫﻭﺍء ﺍﻟﻐﺭﻑ ﻓﻲ‬
‫ﺍﻟﻣﺳﺎﻛﻥ ﺍﻟﻌﺎﺩﻳﺔ‪.‬‬
‫)‪(1‬‬
‫)‪(2‬‬
‫)‪(3‬‬
‫)‪(4‬‬
‫ﺑﺎﺭﺩ ﻭﺟﺎﻑ‪(4) ،(3) ،(2) ،(1) :‬‬
‫)‪(4) ،(3) ،(2) ،(1‬‬
‫ﺍﻟﺗﺩﻓﺋﺔ‪:‬‬
‫ﺗﻠﻣﻳﺣﺎﺕ ﺍﻟﺗﺷﻐﻳﻝ‬
‫ﺍﻟﺗﻧﻅﻳﻑ ﻭﺍﻟﻌﻧﺎﻳﺔ‬
‫ﺗﻧﺑﻳﻪ‬
‫● ﻗﺑﻝ ﺗﻧﻅﻳﻑ ﺍﻟﻭﺣﺩﺓ‪ ،‬ﺗﺄﻛﺩ ﻣﻥ ﺇﻳﻘﺎﻓﻬﺎ ﻭﻓﺻﻝ ﻣﺻﺩﺭ ﺍﻟﻁﺎﻗﺔ‪.‬‬
‫ﺍﻟﺗﺷﻐﻳﻝ ﻭﺍﻷﺩﺍء‬
‫ﺣﻭﻝ ﺣﺎﻟﺔ ﺍﻷﻭﻟﻭﻳﺔ ﻭﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ‬
‫● ﻳﻣﻛﻥ ﺗﻭﺻﻳﻝ ﻭﺣﺩﺍﺕ ﺩﺍﺧﻠﻳﺔ ﻣﺗﻌﺩﺩﺓ ﻋﻠﻰ ﻧﻔﺱ ﺍﻟﻧﻅﺎﻡ‪ .‬ﻭﺗﺑﻌًﺎ ﻟﻠﻧﻅﺎﻡ‪ ،‬ﻳﻛﻭﻥ ﺍﺧﺗﻳﺎﺭ ﻭﺿﻊ ﺍﻟﺗﺷﻐﻳﻝ‬
‫ﻣﺣﺩﻭ ًﺩﺍ‪.‬‬
‫ﺣﺎﻟﺔ ﺃﻭﻟﻭﻳﺔ ﺍﻟﺗﺑﺭﻳﺩ‪:‬‬
‫ﻋﻧﺩ ﺗﺷﻐﻳﻝ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺍﻷﺧﺭﻯ ﻓﻲ ﻧﻔﺱ ﺍﻟﻧﻅﺎﻡ ﻋﻠﻰ ﻭﺿﻊ ﺑﺎﺭﺩ ﻭﺟﺎﻑ‪ ،‬ﻻ ﻳﻣﻛﻥ ﺍﺧﺗﻳﺎﺭ ﺍﻟﺗﺩﻓﺋﺔ‬
‫ﻓﻲ ﻧﻔﺱ ﺍﻟﻭﻗﺕ‪.‬‬
‫ﺣﺎﻟﺔ ﺃﻭﻟﻭﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ‪:‬‬
‫ﻋﻧﺩ ﺗﺷﻐﻳﻝ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺍﻷﺧﺭﻯ ﻓﻲ ﻧﻔﺱ ﺍﻟﻧﻅﺎﻡ ﻋﻠﻰ ﻭﺿﻊ ﺍﻟﺗﺩﻓﺋﺔ‪ ،‬ﻻ ﻳﻣﻛﻥ ﺍﺧﺗﻳﺎﺭ ﻭﺿﻊ ﺑﺎﺭﺩ‬
‫ﻭﺟﺎﻑ ﻓﻲ ﻧﻔﺱ ﺍﻟﻭﻗﺕ‪.‬‬
‫ﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ‪:‬‬
‫ﻳﺗﻡ ﺗﻧﺷﻳﻁ ﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ ﻋﻧﺩ ﺑﺩء ﺗﺷﻐﻳﻝ ﻭﺣﺩﺗﻳﻥ )‪ (2‬ﺃﻭ ﺃﻛﺛﺭ ﻣﻥ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻋﻠﻰ ﻭﺿﻊ‬
‫ﻣﺧﺗﻠﻑ ﻓﻲ ﻧﻔﺱ ﺍﻟﻭﻗﺕ‪ .‬ﻭﺗﻧﺗﻅﺭ ﺃﻱ ﻭﺣﺩﺓ ﺩﺍﺧﻠﻳﺔ ﺑﺧﻼﻑ ﺍﻟﻭﺣﺩﺍﺕ ﺫﺍﺕ ﻭﺿﻊ ﺍﻷﻭﻟﻳﺔ ﻋﻠﻰ ﺣﺎﻟﺔ‬
‫ﺍﻻﺳﺗﻌﺩﺍﺩ ﺣﺗﻰ ﻳﺗﻐﻳﺭ ﻭﺿﻊ ﺍﻷﻭﻟﻭﻳﺔ )ﻭﻳﺑﺩﺃ ﺍﻟﺗﺷﻐﻳﻝ ﺑﻣﺟﺭﺩ ﺗﻐﻳﻳﺭ ﺍﻷﻭﻟﻭﻳﺔ(‪.‬‬
‫ﻓﻲ ﻧﻔﺱ ﺍﻟﻭﻗﺕ‪ ،‬ﻳﺿﻲء ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( ﻭﻳﻭﻣﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺅﻗﺕ‬
‫)ﺍﻟﺑﺭﺗﻘﺎﻟﻲ(‪.‬‬
‫● ﻻ ﺗﻘﻑ ﻋﻠﻰ ﻣﻧﺻﺔ ﻏﻳﺭ ﺛﺎﺑﺗﺔ ﺃﺛﻧﺎء ﺍﻟﺗﻧﻅﻳﻑ‪.‬‬
‫● ﻋﻧﺩ ﺇﺯﺍﻟﺔ ﺃﻭ ﺍﺳﺗﺑﺩﺍﻝ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء‪ ،‬ﺗﺄﻛﺩ ﻣﻥ ﻋﺩﻡ ﻟﻣﺱ ﻣﺑﺎﺩﻝ ﺍﻟﺣﺭﺍﺭﺓ‪ ،‬ﻧﻅﺭً ﺍ ﻷﻧﻪ ﻗﺩ ﺗﺣﺩﺙ ﺇﺻﺎﺑﺔ‬
‫ﺷﺧﺻﻳﺔ‪.‬‬
‫● ﺗﺄﻛﺩ ﻣﻥ ﺗﺭﻛﻳﺏ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ ﺑﺷﻛﻝ ﻣﺣﻛﻡ‪.‬‬
‫● ﻻ ﺗﻘﻡ ﺑﺗﻧﻅﻳﻑ ﺍﻟﻭﺣﺩﺓ ﻣﻥ ﺍﻟﺩﺍﺧﻝ ﺑﻧﻔﺳﻙ‪ .‬ﻟﻠﺗﻧﻅﻳﻑ ﻣﻥ ﺍﻟﺩﺍﺧﻝ‪ ،‬ﺍﺣﺭﺹ ﺩﺍﺋﻣًﺎ ﻋﻠﻰ ﺍﺳﺗﺷﺎﺭﺓ ﻣﻭﻅ‬
‫ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﻣﻌﺗﻣﺩ‪.‬‬
‫● ﻋﻧﺩ ﺗﻧﻅﻳﻑ ﺟﺳﻡ ﺍﻟﻭﺣﺩﺓ‪ ،‬ﻻ ﺗﺳﺗﺧﺩﻡ ﻣﻳﺎﻩ ﺳﺎﺧﻧﺔ ﺗﺯﻳﺩ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺗﻬﺎ ﻋﻥ ‪ 40‬ﺩﺭﺟﺔ ﻣﺋﻭﻳﺔ‪ ،‬ﺃﻭ‬
‫ﻣﻧﻅﻔﺎﺕ ﻗﻭﻳﺔ ﻛﺎﺷﻁﺔ‪ ،‬ﺃﻭ ﻋﻭﺍﻣﻝ ﺗﻧﻅﻳﻑ ﻣﺗﻁﺎﻳﺭﺓ ﻣﺛﻝ ﺍﻟﺑﻧﺯﻳﻥ ﺃﻭ ﻣﺭﻗﻕ ﺍﻟﻁﻼء )ﺍﻟﺗﻧﺭ(‪.‬‬
‫● ﻻ ﺗﻘﻡ ﺑﺈﺯﺍﻟﺔ ﺃﻱ ﺟﺯء ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺑﺎﺳﺗﺛﻧﺎء ﺍﻟﻣﺭﺷﺢ‪.‬‬
‫● ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺳﻣﺎﺡ ﺑﺗﺭﺍﻛﻡ ﺍﻟﻐﺑﺎﺭ ﻋﻠﻰ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء‪ ،‬ﻓﺳﻭﻑ ﻳﻘﻝ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء‪ ،‬ﻣﻣﺎ ﻳﻘﻠﻝ ﻣﻥ ﻛﻔﺎءﺓ‬
‫ﺍﻟﺗﺷﻐﻳﻝ ﻭﺯﻳﺎﺩﺓ ﺍﻟﺿﻭﺿﺎء‪.‬‬
‫● ‪ AUGB 07/09/12/14/18/24‬ﺧﻼﻝ ﻓﺗﺭﺍﺕ ﺍﻻﺳﺗﺧﺩﺍﻡ ﺍﻟﻌﺎﺩﻱ‪ ،‬ﻳﺟﺏ ﺗﻧﻅﻳﻑ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء‬
‫ﻛﻝ ﺷﻬﺭﻳﻥ )‪.(2‬‬
‫● ‪ AUGD 18/24, AUGA 30/36/45/54‬ﺧﻼﻝ ﻓﺗﺭﺍﺕ ﺍﻻﺳﺗﺧﺩﺍﻡ ﺍﻟﻌﺎﺩﻱ‪ ،‬ﻳﺟﺏ ﺗﻧﻅﻳﻑ‬
‫ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ﻛﻝ ﺷﻬﺭﻳﻥ )‪.(2‬‬
‫ﺍﻟﺗﺑﺭﻳﺩ ﺍﻟﻣﺣﻳﻁ ﺍﻟﻣﻧﺧﻔﺽ‬
‫● ﻋﻧﺩﻣﺎ ﺗﻧﺧﻔﺽ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻓﻲ ﺍﻟﺧﺎﺭﺝ‪ ،‬ﻗﺩ ﻳﺗﻡ ﺗﻐﻳﻳﺭ ﻣﺭﺍﻭﺡ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ ﺇﻟﻰ ﺳﺭﻋﺔ ﻣﻧﺧﻔﺿﺔ‪،‬‬
‫ﺃﻭ ﻗﺩ ﺗﺗﻭﻗﻑ ﺇﺣﺩﻯ ﺍﻟﻣﺭﺍﻭﺡ ﺑﺷﻛﻝ ﻣﺗﻘﻁﻊ‪.‬‬
‫‪Ar-2‬‬
‫‪5/15/2017 14:34:10‬‬
‫‪9369313240_OM_AR.indd 2‬‬
‫‪ .3‬ﻗﻡ ﺑﺗﻧﻅﻳﻑ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء‪.‬‬
‫ﺗﻧﻅﻳﻑ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء‬
‫● ﻗﻡ ﺑﺈﺯﺍﻟﺔ ﺍﻟﻐﺑﺎﺭ ﻣﻥ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ﺑﺎﺳﺗﺧﺩﺍﻡ ﻣﻛﻧﺳﺔ ﺃﻭ ﻋﻥ ﻁﺭﻳﻕ ﻏﺳﻠﻬﺎ‪ .‬ﻭﺑﻌﺩ ﺍﻟﻐﺳﻝ‪ ،‬ﺍﺗﺭﻙ‬
‫ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ﺗﺟﻑ ﺑﺎﻟﻛﺎﻣﻝ ﻓﻲ ﻣﻧﻁﻘﺔ ﻣﺣﻣﻳﺔ ﻣﻥ ﺿﻭء ﺍﻟﺷﻣﺱ‪.‬‬
‫‪AUGB 07/09/12/14/18/24‬‬
‫● ﻳﻣﻛﻥ ﺗﻧﻅﻳﻑ ﺍﻟﻐﺑﺎﺭ ﻣﻥ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﺇﻣﺎ ﺑﺎﺳﺗﺧﺩﺍﻡ ﻣﻛﻧﺳﺔ ﻛﻬﺭﺑﺎﺋﻳﺔ‪ ،‬ﺃﻭ ﻏﺳﻝ ﺍﻟﻣﺭﺷﺢ ﻓﻲ ﻣﺣﻠﻭﻝ‬
‫ﻣﻧﻅﻑ ﻣﻌﺗﺩﻝ ﻭﻣﺎء ﺩﺍﻓﺊ‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﻏﺳﻝ ﺍﻟﻣﺭﺷﺢ‪ ،‬ﺗﺄﻛﺩ ﻣﻥ ﺗﺭﻛﻪ ﻳﺟﻑ ﺑﺎﻟﻛﺎﻣﻝ ﻓﻲ ﻣﻛﺎﻥ ﻣﻅﻠﻝ ﻗﺑﻝ‬
‫ﺇﻋﺎﺩﺓ ﺍﻟﺗﺭﻛﻳﺏ‪.‬‬
‫ﻋﻧﺩﻣﺎ ﻳﻭﻣﺽ ﻣﺻﺑﺎﺡ ﺍﻟﻣﺭﺷﺢ‪ ،‬ﻗﻡ ﺑﺈﺯﺍﻟﺔ ﺍﻟﻣﺭﺷﺢ ﻭﺗﻧﻅﻳﻔﻪ‪.‬‬
‫‪ .1‬ﺍﺩﻓﻊ ﺧﻁﺎﻓﺎﺕ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ ﻟﻠﺩﺍﺧﻝ ﻧﺣﻭ ﻭﺳﻁ ﺍﻟﻭﺣﺩﺓ ﻟﻔﺗﺢ ﺷﺑﻛﺔ‬
‫ﺍﻻﻣﺗﺻﺎﺹ‪.‬‬
‫● ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺳﻣﺎﺡ ﺑﺗﺭﺍﻛﻡ ﺍﻟﻐﺑﺎﺭ ﻋﻠﻰ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء‪ ،‬ﻓﺳﻭﻑ ﻳﻘﻝ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء‪ ،‬ﻣﻣﺎ ﻳﻘﻠﻝ ﻣﻥ ﻛﻔﺎءﺓ‬
‫ﺍﻟﺗﺷﻐﻳﻝ ﻭﺯﻳﺎﺩﺓ ﺍﻟﺿﻭﺿﺎء‪.‬‬
‫● ﺑﻌﺩ ﺗﺷﻐﻳﻝ ﺍﻟﻁﺎﻗﺔ‪ ،‬ﺍﺿﻐﻁ ﺯﺭ ‪) MAINTENANCE‬ﺍﻟﺻﻳﺎﻧﺔ( ﻟﻣﺩﺓ ‪ 2‬ﺛﺎﻧﻳﺔ ﺃﻭ ﺃﻛﺛﺭ ﻋﻠﻰ ﻭﺣﺩﺓ‬
‫ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ‪.‬‬
‫‪ .2‬ﺍﺳﺣﺏ ﺍﻟﻣﺭﺷﺢ ﻟﻠﺧﺎﺭﺝ ﻣﻥ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ‪.‬‬
‫‪.1‬‬
‫‪.2‬‬
‫‪ .4‬ﺃﻋﺩ ﺗﺭﻛﻳﺏ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ﻓﻲ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ‪.‬‬
‫)‪ (1‬ﺃﻋﺩ ﺗﺭﻛﻳﺏ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﻓﻲ ﺍﻟﺣﺎﻣﻝ ﺍﻟﺧﺎﺹ ﺑﻪ‪.‬‬
‫)‪ (2‬ﺗﺄﻛﺩ ﻣﻥ ﺃﻥ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﻳﻼﻣﺱ ﺳﺩﺍﺩﺓ ﺍﻟﻣﺭﺷﺢ ﻋﻧﺩ ﺇﻋﺎﺩﺓ ﻭﺿﻌﻪ ﻓﻲ ﺣﺎﻣﻠﻪ‪.‬‬
‫‪ .5‬ﺃﻏﻠﻕ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ ﺛﻡ ﺍﺩﻓﻊ ﺧﻁﺎﻓﺎﺕ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ ﻟﻠﺧﺎﺭﺝ‪.‬‬
‫‪.5‬‬
‫‪.4‬‬
‫ﺧﻁﺎﻑ ﺍﻟﺷﺑﻛﺔ‬
‫ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء‬
‫‪ .3‬ﻗﻡ ﺑﺗﻧﻅﻳﻑ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء‪.‬‬
‫ﻗﻡ ﺑﺈﺯﺍﻟﺔ ﺍﻟﻐﺑﺎﺭ ﻣﻥ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ﺑﺎﺳﺗﺧﺩﺍﻡ ﻣﻛﻧﺳﺔ ﺃﻭ ﻋﻥ ﻁﺭﻳﻕ ﻏﺳﻠﻬﺎ‪ .‬ﻭﺑﻌﺩ ﺍﻟﻐﺳﻝ‪ ،‬ﺍﺗﺭﻙ ﻣﺭﺷﺣﺎﺕ‬
‫ﺍﻟﻬﻭﺍء ﺗﺟﻑ ﺑﺎﻟﻛﺎﻣﻝ ﻓﻲ ﻣﻧﻁﻘﺔ ﻣﺣﻣﻳﺔ ﻣﻥ ﺿﻭء ﺍﻟﺷﻣﺱ‪.‬‬
‫‪ .4‬ﺃﻋﺩ ﺗﺭﻛﻳﺏ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ﻓﻲ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ‪.‬‬
‫ﺗﻧﻅﻳﻑ ﺍﻟﺟﺳﻡ‬
‫)‪ (1‬ﺃﻋﺩ ﺗﺭﻛﻳﺏ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﻓﻲ ﺍﻟﺣﺎﻣﻝ ﺍﻟﺧﺎﺹ ﺑﻪ‪.‬‬
‫)‪ (2‬ﺗﺄﻛﺩ ﻣﻥ ﺃﻥ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﻳﻼﻣﺱ ﺳﺩﺍﺩﺓ ﺍﻟﻣﺭﺷﺢ ﻋﻧﺩ ﺇﻋﺎﺩﺓ ﻭﺿﻌﻪ ﻓﻲ ﺣﺎﻣﻠﻪ‪.‬‬
‫‪ .5‬ﺃﻏﻠﻕ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ ﺛﻡ ﺍﺩﻓﻊ ﺧﻁﺎﻓﺎﺕ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ ﻟﻠﺧﺎﺭﺝ‪.‬‬
‫‪.5‬‬
‫‪.4‬‬
‫ﻗﻡ ﺑﻐﺳﻝ ﺍﻟﺟﺳﻡ ﺑﻣﺎء ﺩﺍﻓﺊ‪ ،‬ﺛﻡ ﻗﻡ ﺑﺗﺟﻔﻳﻔﻪ ﺑﻘﻁﻌﺔ ﻗﻣﺎﺵ ﻧﻅﻳﻔﺔ ﻭﻧﺎﻋﻣﺔ‪.‬‬
‫ﻋﻧﺩ ﻋﺩﻡ ﺍﻻﺳﺗﺧﺩﺍﻡ ﻟﻔﺗﺭﺓ ﻁﻭﻳﻠﺔ‬
‫ﺍﺗﺭﻙ ﺍﻟﻘﺎﻁﻊ ﻗﻳﺩ ﺍﻟﺗﺷﻐﻳﻝ ﻟﻣﺩﺓ ‪ 12‬ﺳﺎﻋﺔ ﻋﻠﻰ ﺍﻷﻗﻝ ﻗﺑﻝ ﺑﺩء ﺍﻟﺗﺷﻐﻳﻝ ﻋﻧﺩ ﺍﻟﺭﻏﺑﺔ ﻓﻲ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﻭﺣﺩﺓ ﻣﺭﺓ‬
‫ﺃﺧﺭﻯ‪.‬‬
‫ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء‬
‫ﺍﺳﺗﻛﺷﺎﻑ ﺍﻷﻋﻁﺎﻝ ﻭﺇﺻﻼﺣﻬﺎ‬
‫ﺧﻁﺎﻑ ﺍﻟﻣﺭﺷﺢ‬
‫ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ‬
‫ﺍﻷﺣﻭﺍﻝ ﺍﻟﺗﺎﻟﻳﺔ ﻻ ﺗﻣﺛﻝ ﺃﻋﻁﺎﻻ ﺃﻭ ﺇﺧﻔﺎ ًﻗﺎ ﻓﻲ ﺍﻟﺗﺷﻐﻳﻝ‪.‬‬
‫ﺧﻁﺎﻑ ﺍﻟﺷﺑﻛﺔ‬
‫ﺗﻌﺫﺭ ﺍﻟﺗﺷﻐﻳﻝ ﻣﺑﺎﺷﺭﺓ‪:‬‬
‫● ﻓﻲ ﺣﺎﻟﺔ ﺇﻳﻘﺎﻑ ﺍﻟﻭﺣﺩﺓ ﺛﻡ ﺗﺷﻐﻳﻠﻬﺎ ﻣﺭﺓ ﺃﺧﺭﻯ ﻋﻠﻰ ﺍﻟﻔﻭﺭ‪ ،‬ﻟﻥ ﻳﻌﻣﻝ ﺍﻟﺿﺎﻏﻁ ﻟﻣﺩﺓ ‪ 3‬ﺩﻗﺎﺋﻕ ﺗﻘﺭﻳﺑًﺎ‪ ،‬ﻣﻥ‬
‫ﺃﺟﻝ ﻣﻧﻊ ﺗﻠﻑ ﺍﻟﻣﺻﻬﺭ‪.‬‬
‫● ﻳﻣﻛﻥ ﺗﻧﻅﻳﻑ ﺍﻟﻐﺑﺎﺭ ﻣﻥ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﺇﻣﺎ ﺑﺎﺳﺗﺧﺩﺍﻡ ﻣﻛﻧﺳﺔ ﻛﻬﺭﺑﺎﺋﻳﺔ‪ ،‬ﺃﻭ ﻏﺳﻝ ﺍﻟﻣﺭﺷﺢ ﻓﻲ ﻣﺣﻠﻭﻝ‬
‫ﻣﻧﻅﻑ ﻣﻌﺗﺩﻝ ﻭﻣﺎء ﺩﺍﻓﺊ‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﻏﺳﻝ ﺍﻟﻣﺭﺷﺢ‪ ،‬ﺗﺄﻛﺩ ﻣﻥ ﺗﺭﻛﻪ ﻳﺟﻑ ﺑﺎﻟﻛﺎﻣﻝ ﻓﻲ ﻣﻛﺎﻥ ﻣﻅﻠﻝ ﻗﺑﻝ‬
‫ﺇﻋﺎﺩﺓ ﺍﻟﺗﺭﻛﻳﺏ‪.‬‬
‫● ﻓﻲ ﺣﺎﻟﺔ ﻓﺻﻝ ﺍﻟﻘﺎﻁﻊ ﺍﻟﻛﻬﺭﺑﺎﺋﻲ ﺛﻡ ﺗﻭﺻﻳﻠﻪ ﻣﺭﺓ ﺃﺧﺭﻯ‪ ،‬ﻓﺳﻭﻑ ﺗﻌﻣﻝ ﺩﺍﺋﺭﺓ ﺍﻟﺣﻣﺎﻳﺔ ﻟﻣﺩﺓ ‪ 3‬ﺗﻘﺭﻳﺑًﺎ‪،‬‬
‫ﺑﺣﻳﺙ ﺗﻣﻧﻊ ﺗﺷﻐﻳﻝ ﺍﻟﻭﺣﺩﺓ ﺧﻼﻝ ﻫﺫﻩ ﺍﻟﻔﺗﺭﺓ‪.‬‬
‫● ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺳﻣﺎﺡ ﺑﺗﺭﺍﻛﻡ ﺍﻟﻐﺑﺎﺭ ﻋﻠﻰ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء‪ ،‬ﻓﺳﻭﻑ ﻳﻘﻝ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء‪ ،‬ﻣﻣﺎ ﻳﻘﻠﻝ ﻣﻥ ﻛﻔﺎءﺓ‬
‫ﺍﻟﺗﺷﻐﻳﻝ ﻭﺯﻳﺎﺩﺓ ﺍﻟﺿﻭﺿﺎء‪.‬‬
‫ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ﺿﻌﻳﻑ ﺃﻭ ﻳﺗﻭﻗﻑ‪:‬‬
‫● ﻋﻧﺩ ﺑﺩء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ‪ ،‬ﻗﺩ ﺗﺗﻭﻗﻑ ﻣﺭﻭﺣﺔ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻣﺅﻗ ًﺗﺎ ﻟﻠﺳﻣﺎﺡ ﺑﺗﺳﺧﻳﻥ ﺍﻷﺟﺯﺍء ﺍﻟﺩﺍﺧﻠﻳﺔ‪.‬‬
‫● ﺑﻌﺩ ﺗﺷﻐﻳﻝ ﺍﻟﻁﺎﻗﺔ‪ ،‬ﺍﺿﻐﻁ ﺯﺭ ﺍﻟﻣﺭﺷﺢ ﻋﻠﻰ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﻹﻳﻘﺎﻑ ﺗﺷﻐﻳﻝ ﻣﺻﺑﺎﺡ ﺍﻟﻣﺭﺷﺢ‪.‬‬
‫)ﺭﺍﺟﻊ ﺩﻟﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ ﺍﻟﻣﺭﻓﻕ ﻣﻊ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﻟﻠﺣﺻﻭﻝ ﻋﻠﻰ ﺗﻔﺎﺻﻳﻝ‪(.‬‬
‫● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ‪ ،‬ﺇﺫﺍ ﺍﺭﺗﻔﻌﺕ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺍﻟﻐﺭﻓﺔ ﺃﻋﻠﻰ ﻣﻥ ﺇﻋﺩﺍﺩ ﻣﻧﻅﻡ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ‪ ،‬ﻓﺳﻭﻑ‬
‫ﺗﺗﻭﻗﻑ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ‪ ،‬ﻭﺗﺗﻭﻗﻑ ﻣﺭﻭﺣﺔ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ‪ .‬ﺇﺫﺍ ﺃﺭﺩﺕ ﺗﺩﻓﺋﺔ ﺍﻟﻐﺭﻓﺔ ﺑﺷﻛﻝ ﺇﺿﺎﻓﻲ‪ ،‬ﻗﻡ‬
‫ﺑﺿﺑﻁ ﻣﻧﻅﻡ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻋﻠﻰ ﺇﻋﺩﺍﺩ ﺃﻋﻠﻰ‪.‬‬
‫‪AUGD 18/24, AUGA 30/36/45/54‬‬
‫ﻋﻧﺩﻣﺎ ﻳﻭﻣﺽ ﻣﺻﺑﺎﺡ ﺍﻟﻣﺭﺷﺢ‪ ،‬ﻗﻡ ﺑﺈﺯﺍﻟﺔ ﺍﻟﻣﺭﺷﺢ ﻭﺗﻧﻅﻳﻔﻪ‪.‬‬
‫● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ‪ ،‬ﻗﺩ ﻳﺗﻭﻗﻑ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ﻟﻣﺩﺓ ‪ 10‬ﺩﻗﺎﺋﻕ ﺗﻘﺭﻳﺑًﺎ‪) .‬ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ‪ ،‬ﺗﺗﻭﻗﻑ ﺍﻟﻭﺣﺩﺓ ﻋﻥ ﺍﻟﺗﺷﻐﻳﻝ ﻣﺅﻗ ًﺗﺎ )ﻣﺎ ﺑﻳﻥ ‪ 4‬ﻭ‪ 15‬ﺩﻗﻳﻘﺔ( ﻧﻅﺭً ﺍ ﻟﺗﺷﻐﻳﻝ ﻭﺿﻊ ﺇﺫﺍﺑﺔ‬
‫ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ‪) .‬ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫‪ .1‬ﺍﺩﻓﻊ ﺧﻁﺎﻓﺎﺕ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ ﻟﻠﺩﺍﺧﻝ ﻧﺣﻭ ﻭﺳﻁ ﺍﻟﻭﺣﺩﺓ ﻟﻔﺗﺢ ﺷﺑﻛﺔ‬
‫ﺍﻻﻣﺗﺻﺎﺹ‪.‬‬
‫● ﻗﺩ ﺗﻌﻣﻝ ﺍﻟﻣﺭﻭﺣﺔ ﺑﺳﺭﻋﺔ ﻣﻧﺧﻔﺿﺔ ﺃﺛﻧﺎء ﺗﺷﻐﻳﻝ ﻭﺿﻊ ﺟﺎﻑ ﺃﻭ ﻋﻧﺩ ﻣﺭﺍﻗﺑﺔ ﺍﻟﻭﺣﺩﺓ ﻟﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ‬
‫ﺍﻟﻐﺭﻓﺔ‪.‬‬
‫‪ .2‬ﺍﺳﺣﺏ ﺍﻟﻣﺭﺷﺢ ﻟﻠﺧﺎﺭﺝ ﻣﻥ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ‪.‬‬
‫‪.2‬‬
‫‪.1‬‬
‫● ﻓﻲ ﻭﺿﻊ ﻋﻣﻠﻳﺔ ﺍﻟﻣﺭﺍﻗﺑﺔ ﺍﻟﺗﻠﻘﺎﺋﻲ‪ ،‬ﺗﻌﻣﻝ ﺍﻟﻣﺭﻭﺣﺔ ﺑﺳﺭﻋﺔ ﻣﻧﺧﻔﺿﺔ‪.‬‬
‫ﺍﻟﻣﺻﺎﺑﻳﺢ ﺍﻟﻭﺍﻣﺿﺔ‪:‬‬
‫● ﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ(‪:‬‬
‫ﻳﺟﺭﻱ ﺗﻧﻔﻳﺫ ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ‪) .‬ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫● ﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ(‪:‬‬
‫ﻳﺟﺭﻱ ﺗﻧﻔﻳﺫ ﻋﻣﻠﻳﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ‪) .‬ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫● ﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( ﻭﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺅﻗﺕ )ﺍﻟﺑﺭﺗﻘﺎﻟﻲ( ﺑﺎﻟﺗﺑﺎﺩﻝ‪:‬‬
‫ﺗﻡ ﺍﻻﺳﺗﺭﺩﺍﺩ ﻣﻥ ﺍﻧﻘﻁﺎﻉ ﺍﻟﺗﻳﺎﺭ‪.‬‬
‫‪Ar-3‬‬
‫‪5/15/2017 14:34:10‬‬
‫‪9369313240_OM_AR.indd 3‬‬
‫● ﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( ﻭﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺅﻗﺕ )ﺍﻟﺑﺭﺗﻘﺎﻟﻲ( ﻓﻲ ﺁﻥ ﻭﺍﺣﺩ‪:‬‬
‫ﻳﺗﻡ ﺍﻟﺗﺷﻐﻳﻝ ﻓﻲ ﺍﻟﻭﺿﻊ ﺍﻟﺗﺟﺭﻳﺑﻲ‪ .‬ﺍﺳﺄﻝ ﺍﻟﻣﺩﻳﺭ ﻓﻘﺩ ﺗﻛﻭﻥ ﻫﻧﺎﻙ ﺻﻳﺎﻧﺔ ﻗﻳﺩ ﺍﻟﺗﻧﻔﻳﺫ‪.‬‬
‫ﺍﻟﻣﻭﺍﺻﻔﺎﺕ‬
‫● ﺇﺿﺎءﺓ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( ﻭﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺅﻗﺕ )ﺍﻟﺑﺭﺗﻘﺎﻟﻲ(‪:‬‬
‫ﻫﺫﻩ ﻫﻲ ﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ‪) .‬ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫ﺳﻣﺎﻉ ﺿﻭﺿﺎء‪:‬‬
‫● ﻓﻲ ﺍﻷﺣﻭﺍﻝ ﺍﻟﺗﺎﻟﻳﺔ ﺗﻅﻬﺭ ﺃﺻﻭﺍﺕ ﺗﺩﻓﻕ ﺍﻟﻣﻳﺎﻩ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻭﻳﺻﺑﺢ ﺻﻭﺕ ﺍﻟﺗﺷﻐﻳﻝ ﻣﺭﺗﻔﻊ‪ .‬ﺗﻭﺟﺩ‬
‫ﺃﺻﻭﺍﺕ ﻟﺗﺩﻓﻕ ﺳﺎﺋﻝ ﺍﻟﺗﺑﺭﻳﺩ‪.‬‬
‫ﻋﻧﺩ ﺑﺩء ﺍﻟﻌﻣﻠﻳﺔ‬
‫ﻋﻧﺩ ﺍﻧﺗﻬﺎء ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ‬
‫ﻋﻧﺩ ﺍﻧﺗﻬﺎء ﻋﻣﻠﻳﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ‬
‫● ﺃﺛﻧﺎء ﺍﻟﺗﺷﻐﻳﻝ‪ ،‬ﻗﺩ ﻳﻅﻬﺭ ﺻﻭﺕ ﺻﺭﻳﺭ ﻁﻔﻳﻑ‪ .‬ﻭﻫﺫﺍ ﻳﻧﺗﺞ ﻋﻥ ﺍﻟﺗﻣﺩﺩ ﻭﺍﻻﻧﻛﻣﺎﺵ ﺍﻟﻠﺣﻅﻲ ﻟﻠﻭﺣﺔ ﺑﺳﺑﺏ‬
‫ﺍﻟﺗﻐﻳﻳﺭﺍﺕ ﻓﻲ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ‪.‬‬
‫‪AUGB‬‬
‫‪07‬‬
‫‪GATH‬‬
‫ﺍﻟﻁﺭﺍﺯ‬
‫ﻣﺻﺩﺭ ﺍﻟﻁﺎﻗﺔ‬
‫‪ 240-220‬ﻓﻭﻟﺕ ﻓﻭﻟﺕ ~ ‪ 50‬ﻫﺭﺗﺯ‪ 230 ،‬ﻓﻭﻟﺕ ﻓﻭﻟﺕ ~ ‪ 60‬ﻫﺭﺗﺯ‬
‫ﻣﺩﻯ ﻓﺭﻕ ﺍﻟﺟﻬﺩ ﺍﻟﻣﺗﺎﺡ‬
‫ﻗﺩﺭﺓ ﺍﻟﺗﺑﺭﻳﺩ‬
‫‪2.2‬‬
‫‪2.8‬‬
‫]ﺑﺎﻟﻛﻳﻠﻭ ﻭﺍﺕ[‬
‫]ﻭﺣﺩﺓ ﺣﺭﺍﺭﻳﺔ‬
‫ﺑﺭﻳﻁﺎﻧﻳﺔ‪/‬ﺳﺎﻋﺔ[‬
‫‪7,500‬‬
‫‪9,600‬‬
‫]ﺑﺎﻟﻛﻳﻠﻭ ﻭﺍﺕ[‬
‫‪2.8‬‬
‫‪3.2‬‬
‫]ﻭﺣﺩﺓ ﺣﺭﺍﺭﻳﺔ‬
‫ﺑﺭﻳﻁﺎﻧﻳﺔ‪/‬ﺳﺎﻋﺔ[‬
‫‪9,600‬‬
‫● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ‪ ،‬ﻗﺩ ﻳﺗﻡ ﺳﻣﺎﻉ ﺻﻭﺕ ﻫﺳﻳﺱ ﻓﻲ ﺑﻌﺽ ﺍﻷﺣﻳﺎﻥ‪ .‬ﻳﻧﺗﺞ ﻫﺫﺍ ﺍﻟﺻﻭﺕ ﻋﻥ ﻋﻣﻠﻳﺔ ﺇﺫﺍﺑﺔ‬
‫ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ‪) .‬ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫ﺍﻟﺭﻭﺍﺋﺢ‪:‬‬
‫● ﻗﺩ ﺗﻧﺑﻌﺙ ﺑﻌﺽ ﺍﻟﺭﻭﺍﺋﺢ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ‪ .‬ﻫﺫﻩ ﺍﻟﺭﺍﺋﺣﺔ ﺗﻛﻭﻥ ﻧﺎﺗﺟﺔ ﻋﻥ ﺍﻟﺭﻭﺍﺋﺢ ﻓﻲ ﺍﻟﻐﺭﻓﺔ )ﻣﺛﻝ‬
‫ﺭﻭﺍﺋﺢ ﺍﻟﻔﺎﻛﻬﺔ ﺃﻭ ﺍﻟﺗﺑﻎ ﺃﻭ ﻏﻳﺭﻩ( ﻭﺍﻟﺗﻲ ﻳﺗﻡ ﺍﻣﺗﺻﺎﺻﻬﺎ ﻓﻲ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء‪.‬‬
‫ﻁﺎﻗﺔ ﺍﻹﺩﺧﺎﻝ ]ﻭﺍﺕ[‬
‫ﺧﺭﻭﺝ ﺑﺧﺎﺭ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ‪:‬‬
‫● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ‪ ،‬ﻗﺩ ﺗﺗﻭﻗﻑ ﻣﺭﻭﺣﺔ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ‪ ،‬ﻭﻗﺩ ﺗﺗﻡ ﻣﺷﺎﻫﺩﺓ ﺑﺧﺎﺭ ﻳﺗﺻﺎﻋﺩ ﻣﻥ ﺍﻟﻭﺣﺩﺓ‪.‬‬
‫ﻭﻫﺫﺍ ﻳﻧﺷﺄ ﺑﺳﺑﺏ ﻋﻣﻠﻳﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ‪) .‬ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫ﺇﺧﺭﺍﺝ ﻣﺎء ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ‪:‬‬
‫● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ‪ ،‬ﻗﺩ ﻳﺧﺭﺝ ﻣﺎء ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ ﺑﺳﺑﺏ ﻋﻣﻠﻳﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ‪.‬‬
‫ﺍﻷﺣﻭﺍﻝ ﺍﻟﺗﺎﻟﻳﺔ ﻗﺩ ﻻ ﺗﻛﻭﻥ ﺃﻋﻁﺎﻝ ﻟﺫﺍ ﻗﻡ ﺑﺎﻟﻔﺣﺹ ﻣﺭﺓ ﺃﺧﺭﻯ‪.‬‬
‫ﻋﺩﻡ ﺍﻟﺗﺷﻐﻳﻝ ﻣﻁﻠ ًﻘﺎ‪:‬‬
‫● ﻫﻝ ﻛﺎﻥ ﻫﻧﺎﻙ ﺍﻧﻘﻁﺎﻉ ﻓﻲ ﺍﻟﻁﺎﻗﺔ؟‬
‫● ﻫﻝ ﺗﻠﻑ ﺍﻟﻣﺻﻬﺭ‪ ،‬ﺃﻭ ﺗﻡ ﺗﻌﻁﻳﻝ ﻗﺎﻁﻊ ﺍﻟﺩﺍﺋﺭﺓ؟‬
‫‪AUGB‬‬
‫‪09‬‬
‫‪GATH‬‬
‫‪AUGB‬‬
‫‪18‬‬
‫‪GATH‬‬
‫‪ 198‬ﺇﻟﻰ ‪ 264‬ﻓﻭﻟﺕ )‪ 50‬ﻫﺭﺗﺯ(‪ 198 ،‬ﺇﻟﻰ ‪ 253‬ﻓﻭﻟﺕ )‪ 60‬ﻫﺭﺗﺯ(‬
‫ﻗﺩﺭﺓ ﺍﻟﺗﺩﻓﺋﺔ‬
‫ﺧﺭﻭﺝ ﺿﺑﺎﺏ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ‪:‬‬
‫● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺑﺭﻳﺩ‪ ،‬ﻗﺩ ﺗﺗﻡ ﻣﺷﺎﻫﺩﺓ ﺿﺑﺎﺏ ﺭﻓﻳﻊ ﻳﻧﺑﻌﺙ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ‪ .‬ﻳﻧﺗﺞ ﻫﺫﺍ ﺍﻷﻣﺭ ﺑﺳﺑﺏ‬
‫ﺍﻟﺗﺑﺭﻳﺩ ﺍﻟﻣﻔﺎﺟﺊ ﻟﻬﻭﺍء ﺍﻟﻐﺭﻓﺔ ﺑﻭﺍﺳﻁﺔ ﺍﻟﻬﻭﺍء ﺍﻟﻣﻧﺑﻌﺙ ﻣﻥ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء‪ ،‬ﻣﻣﺎ ﻳﺅﺩﻱ ﺇﻟﻰ ﺍﻟﺗﻛﺛﻳﻑ‬
‫ﻭﺗﻛﻭﻥ ﺍﻟﺿﺑﺎﺏ‪.‬‬
‫‪AUGB‬‬
‫‪12‬‬
‫‪GATH‬‬
‫‪AUGB‬‬
‫‪14‬‬
‫‪GATH‬‬
‫‪AUGB‬‬
‫‪24‬‬
‫‪GATH‬‬
‫ﺍﻟﺗﻳﺎﺭ‬
‫]‪[A‬‬
‫‪4.5‬‬
‫‪3.6‬‬
‫‪7.1‬‬
‫‪5.6‬‬
‫‪24,200 19,100 15,400 12,300‬‬
‫‪5.0‬‬
‫‪4.1‬‬
‫‪8.0‬‬
‫‪6.3‬‬
‫‪27,300 21,500 17,100 14,000 10,900‬‬
‫‪25‬‬
‫‪25‬‬
‫‪29‬‬
‫‪35‬‬
‫‪36‬‬
‫‪84‬‬
‫‪0.17‬‬
‫‪0.17‬‬
‫‪0.20‬‬
‫‪0.24‬‬
‫‪0.25‬‬
‫‪0.62‬‬
‫ﻣﺳﺗﻭﻯ ﺍﻟﺿﻐﻁ ﺍﻟﺻﻭﺗﻲ‬
‫‪34‬‬
‫‪35‬‬
‫‪37‬‬
‫‪38‬‬
‫‪41‬‬
‫‪50‬‬
‫ﻣﺭﺗﻔﻊ‬
‫ﺩﻳﺳﻳﺑﻝ ]‪[A‬‬
‫ﻣﺗﻭﺳﻁ‬
‫ﺩﻳﺳﻳﺑﻝ ]‪[A‬‬
‫‪30‬‬
‫‪30‬‬
‫‪34‬‬
‫‪34‬‬
‫‪35‬‬
‫‪44‬‬
‫ﻣﻧﺧﻔﺽ‬
‫ﺩﻳﺳﻳﺑﻝ ]‪[A‬‬
‫‪25‬‬
‫‪25‬‬
‫‪27‬‬
‫‪27‬‬
‫‪27‬‬
‫‪30‬‬
‫ﺍﻷﺑﻌﺎﺩ ﻭﺍﻟﻭﺯﻥ‬
‫ﺍﻻﺭﺗﻔﺎﻉ‬
‫]ﻣﻡ[‬
‫‪245‬‬
‫ﺍﻟﻌﺭﺽ‬
‫]ﻣﻡ[‬
‫‪570‬‬
‫ﺍﻟﻌﻣﻕ‬
‫]ﻣﻡ[‬
‫ﺍﻟﻭﺯﻥ‬
‫]ﻛﺟﻡ[‬
‫‪570‬‬
‫‪15‬‬
‫‪AUGD‬‬
‫‪18‬‬
‫‪GATH‬‬
‫ﺍﻟﻁﺭﺍﺯ‬
‫‪AUGD‬‬
‫‪24‬‬
‫‪GATH‬‬
‫‪17‬‬
‫‪AUGA‬‬
‫‪30‬‬
‫‪GATH‬‬
‫‪AUGA‬‬
‫‪45‬‬
‫‪GATH‬‬
‫‪AUGA‬‬
‫‪36‬‬
‫‪GATH‬‬
‫‪AUGA‬‬
‫‪54‬‬
‫‪GATH‬‬
‫● ﻫﻝ ﺗﻡ ﺇﻋﺩﺍﺩ ﻣﻔﺗﺎﺡ ﺍﻟﻁﺎﻗﺔ ﺍﻟﺭﺋﻳﺳﻲ ﻋﻠﻰ ﻭﺿﻊ ﺇﻳﻘﺎﻑ ﺍﻟﺗﺷﻐﻳﻝ؟‬
‫ﻣﺻﺩﺭ ﺍﻟﻁﺎﻗﺔ‬
‫‪ 240-220‬ﻓﻭﻟﺕ ﻓﻭﻟﺕ ~ ‪ 50‬ﻫﺭﺗﺯ‪ 230 ،‬ﻓﻭﻟﺕ ﻓﻭﻟﺕ ~ ‪ 60‬ﻫﺭﺗﺯ‬
‫● ﻫﻝ ﺗﺣﺎﻭﻝ ﺍﻟﺗﺷﻐﻳﻝ ﻓﻲ ﻭﺿﻊ ﻣﺧﺗﻠﻑ ﻋﻥ ﺣﺎﻟﺔ ﺍﻷﻭﻟﻭﻳﺔ؟ )ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫ﻣﺩﻯ ﻓﺭﻕ ﺍﻟﺟﻬﺩ ﺍﻟﻣﺗﺎﺡ‬
‫‪ 198‬ﺇﻟﻰ ‪ 264‬ﻓﻭﻟﺕ )‪ 50‬ﻫﺭﺗﺯ(‪ 198 ،‬ﺇﻟﻰ ‪ 253‬ﻓﻭﻟﺕ )‪ 60‬ﻫﺭﺗﺯ(‬
‫● ﻫﻝ ﺍﻟﻭﺣﺩﺓ ﻓﻲ ﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ؟ )ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫ﺗﻌﺫﺭ ﺗﻐﻳﻳﺭ ﻭﺿﻊ ﺍﻟﺗﺷﻐﻳﻝ‪:‬‬
‫● ﻫﻝ ﺗﺣﺎﻭﻝ ﺗﻐﻳﻳﺭ ﺍﻟﺗﺷﻐﻳﻝ ﺇﻟﻰ ﻭﺿﻊ ﻣﺧﺗﻠﻑ ﻋﻥ ﺍﻷﺣﻭﺍﻝ ﺫﺍﺕ ﺍﻷﻭﻟﻭﻳﺔ؟ )ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫ﺿﻌﻑ ﺃﺩﺍء ﺍﻟﺗﺑﺭﻳﺩ )ﺃﻭ ﺍﻟﺗﺩﻓﺋﺔ(‪:‬‬
‫● ﻫﻝ ﻗﻣﺕ ﺑﺿﺑﻁ ﺇﻋﺩﺍﺩﺍﺕ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺍﻟﻐﺭﻓﺔ ﺑﺷﻛﻝ ﺻﺣﻳﺢ )ﻣﻧﻅﻣﺔ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ(؟‬
‫● ﻫﻝ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﻣﺗﺳﺦ؟ )ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫● ﻫﻝ ﻣﻧﻔﺫ ﺍﻹﺩﺧﺎﻝ ﺃﻭ ﻣﻧﻔﺫ ﺍﻹﺧﺭﺍﺝ ﻓﻲ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻣﺳﺩﻭﺩ؟‬
‫]ﺑﺎﻟﻛﻳﻠﻭ ﻭﺍﺕ[‬
‫ﻗﺩﺭﺓ ﺍﻟﺗﺑﺭﻳﺩ ]ﻭﺣﺩﺓ ﺣﺭﺍﺭﻳﺔ‬
‫ﺑﺭﻳﻁﺎﻧﻳﺔ‪/‬ﺳﺎﻋﺔ[‬
‫]ﺑﺎﻟﻛﻳﻠﻭ ﻭﺍﺕ[‬
‫ﻗﺩﺭﺓ ﺍﻟﺗﺩﻓﺋﺔ ]ﻭﺣﺩﺓ ﺣﺭﺍﺭﻳﺔ‬
‫ﺑﺭﻳﻁﺎﻧﻳﺔ‪/‬ﺳﺎﻋﺔ[‬
‫ﻁﺎﻗﺔ ﺍﻹﺩﺧﺎﻝ ]ﻭﺍﺕ[‬
‫● ﻫﻝ ﻫﻧﺎﻙ ﻧﺎﻓﺫﺓ ﺃﻭ ﺑﺎﺏ ﻣﻔﺗﻭﺡ؟‬
‫ﺍﻟﺗﻳﺎﺭ‬
‫● ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺗﺑﺭﻳﺩ‪ ،‬ﻫﻝ ﻫﻧﺎﻙ ﻧﺎﻓﺫﺓ ﺗﺳﻣﺢ ﺑﺩﺧﻭﻝ ﺿﻭء ﺷﻣﺱ ﺳﺎﻁﻊ؟ )ﺃﻏﻠﻕ ﺍﻟﺳﺗﺎﺋﺭ‪(.‬‬
‫ﻣﺳﺗﻭﻯ ﺍﻟﺿﻐﻁ ﺍﻟﺻﻭﺗﻲ‬
‫● ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺗﺑﺭﻳﺩ‪ ،‬ﻫﻝ ﻫﻧﺎﻙ ﺟﻬﺎﺯ ﺗﺳﺧﻳﻥ ﺃﻭ ﺃﺟﻬﺯﺓ ﻛﻣﺑﻳﻭﺗﺭ ﺩﺍﺧﻝ ﺍﻟﻐﺭﻓﺔ‪ ،‬ﺃﻭ ﻫﻝ ﻳﻭﺟﺩ ﻋﺩﺩ ﻛﺑﻳﺭ ﻣﻥ‬
‫ﺍﻷﺷﺧﺎﺹ ﻓﻲ ﺍﻟﻐﺭﻓﺔ؟‬
‫● ﻫﻝ ﺗﻡ ﺿﺑﻁ ﺳﺭﻋﺔ ﺍﻟﻣﺭﻭﺣﺔ ﻋﻠﻰ ﺇﻋﺩﺍﺩ ﻣﻧﺧﻔﺽ؟‬
‫ﺿﺑﻁ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻋﻠﻰ ﺩﺭﺟﺔ ﺃﻗﻝ ﻣﻥ ﺣﺭﺍﺭﺓ ﺍﻟﻐﺭﻓﺔ ﻭﺍﺳﺗﺧﺩﺍﻣﻬﺎ‪:‬‬
‫● ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻻ ﺗﻧﺧﻔﺽ ﺟﻳ ًﺩﺍ‪ .‬ﻗﺩ ﻻ ﺗﻧﺧﻔﺽ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﺗﺑﻌًﺎ ﻷﺣﻭﺍﻝ ﺍﻟﻐﺭﻓﺔ‪) .‬ﺣﻳﻧﻣﺎ ﺗﻛﻭﻥ‬
‫ﺍﻟﺭﻁﻭﺑﺔ ﻣﺭﺗﻔﻌﺔ ﺃﻭ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺍﻟﻐﺭﻓﺔ ﻣﺭﺗﻔﻌﺔ(‪) .‬ﺭﺍﺟﻊ ﺻﻔﺣﺔ ‪(2‬‬
‫ﻓﻲ ﺍﻟﻣﻭﺍﻗﻑ ﺍﻟﺗﺎﻟﻳﺔ ﺃﻭﻗﻑ ﺍﻟﺗﺷﻐﻳﻝ ﻋﻠﻰ ﺍﻟﻔﻭﺭ ﻭﺍﺗﺻﻝ ﻣﻊ ﻣﻭﻅﻔﻲ ﺍﻟﺻﻳﺎﻧﺔ‬
‫ﺍﻟﻣﻌﺗﻣﺩﻳﻥ‪.‬‬
‫● ﺗﻌﺫﺭ ﺣﻝ ﺍﻟﻣﺷﻛﻠﺔ ﺣﺗﻰ ﻓﻲ ﺣﺎﻟﺔ ﺗﻧﻔﻳﺫ ﻓﺣﻭﺻﺎﺕ ﺍﺳﺗﻛﺷﺎﻑ ﺍﻷﺧﻁﺎء ﻭﺇﺻﻼﺣﻬﺎ‪.‬‬
‫● ﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺭﺷﺢ )ﺍﻷﺣﻣﺭ( ﺑﺳﺭﻋﺔ ﺷﺩﻳﺩﺓ‪.‬‬
‫● ﻅﻬﻭﺭ ﻋﻼﻣﺔ ‪ Er‬ﻋﻠﻰ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺳﻠﻛﻳﺔ ﺃﻭ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺑﺳﻳﻁﺔ )ﻋﻥ ﺍﻟﺗﻭﺻﻳﻝ(‪.‬‬
‫]‪[A‬‬
‫‪7.1‬‬
‫‪5.6‬‬
‫‪9.0‬‬
‫‪12.5‬‬
‫‪11.2‬‬
‫‪14.0‬‬
‫‪19,100‬‬
‫‪24,200‬‬
‫‪30,700‬‬
‫‪38,200‬‬
‫‪42,700‬‬
‫‪47,800‬‬
‫‪6.3‬‬
‫‪8.0‬‬
‫‪10.0‬‬
‫‪12.5‬‬
‫‪14.0‬‬
‫‪16.0‬‬
‫‪21,500‬‬
‫‪27,300‬‬
‫‪34,100‬‬
‫‪42,700‬‬
‫‪47,800‬‬
‫‪54,600‬‬
‫‪39‬‬
‫‪46‬‬
‫‪59‬‬
‫‪80‬‬
‫‪99‬‬
‫‪119‬‬
‫‪0.27‬‬
‫‪0.32‬‬
‫‪0.42‬‬
‫‪0.53‬‬
‫‪0.69‬‬
‫‪0.78‬‬
‫ﻣﺭﺗﻔﻊ‬
‫ﺩﻳﺳﻳﺑﻝ ]‪[A‬‬
‫‪36‬‬
‫‪38‬‬
‫‪40‬‬
‫‪44‬‬
‫‪46‬‬
‫‪47‬‬
‫ﻣﺗﻭﺳﻁ‬
‫ﺩﻳﺳﻳﺑﻝ ]‪[A‬‬
‫‪30‬‬
‫‪33‬‬
‫‪38‬‬
‫‪38‬‬
‫‪39‬‬
‫‪39‬‬
‫ﻣﻧﺧﻔﺽ‬
‫ﺩﻳﺳﻳﺑﻝ ]‪[A‬‬
‫‪29‬‬
‫‪29‬‬
‫‪33‬‬
‫‪33‬‬
‫‪33‬‬
‫‪33‬‬
‫ﺍﻷﺑﻌﺎﺩ ﻭﺍﻟﻭﺯﻥ‬
‫ﺍﻻﺭﺗﻔﺎﻉ‬
‫]ﻣﻡ[‬
‫ﺍﻟﻌﺭﺽ‬
‫‪246‬‬
‫‪288‬‬
‫]ﻣﻡ[‬
‫‪840‬‬
‫‪840‬‬
‫ﺍﻟﻌﻣﻕ‬
‫]ﻣﻡ[‬
‫‪840‬‬
‫‪840‬‬
‫ﺍﻟﻭﺯﻥ‬
‫]ﻛﺟﻡ[‬
‫‪22‬‬
‫‪27‬‬
‫ﻣﻌﻠﻭﻣﺎﺕ ﺍﻟﺿﻭﺿﺎء ﺍﻟﻣﺳﻣﻭﻋﺔ ‪:‬‬
‫ﻳﻛﻭﻥ ﺍﻟﺣﺩ ﺍﻷﻗﺻﻰ ﻟﻣﺳﺗﻭﻯ ﺍﻟﺿﻐﻁ ﺍﻟﺻﻭﺗﻲ ﺃﻗﻝ ﻣﻥ ‪ 70‬ﺩﻳﺳﻳﺑﻝ )‪ (A‬ﻟﻛﻝ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻭﺍﻟﻭﺣﺩﺓ‬
‫ﺍﻟﺧﺎﺭﺟﻳﺔ‪ .‬ﺗﺑﻌًﺎ ﻟﻣﻌﻳﺎﺭ ‪ IEC 704-1‬ﻭ‪.ISO 3744‬‬
‫● ﺷﻡ ﺭﺍﺋﺣﺔ ﺣﺭﻳﻕ‪.‬‬
‫‪Ar-4‬‬
‫‪5/15/2017 14:34:10‬‬
‫‪9369313240_OM_AR.indd 4‬‬
9369313240_OM_EN.indd 6
5/15/2017 14:31:43
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project