Fujitsu AUSA18FRTB Installation Manual

Fujitsu AUSA18FRTB Installation Manual
‫‪ .٨‬ﺷﺎﺷﺔ ‪LED‬‬
‫ﻃﺮﺍﺯ ﺍﻟﺘﺪﻓﺌﺔ ﻭﺍﻟﺘﺒﺮﻳﺪ )ﺍﻟﺪﻭﺭﺓ ﺍﻟﻌﻜﺴﻴﺔ( ﻓﻘﻂ‬
‫ﻋﻨﺪ ﺣﺪﻭﺙ ﻋﻄﻞ ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪ ،‬ﺗﻀﻲء ﻣﺼﺎﺑﻴﺢ ‪ LED‬ﻋﻠﻰ ﻟﻮﺣﺔ‬
‫ﺍﻟﺪﺍﺋﺮﺓ ﻟﻺﺷﺎﺭﺓ ﺇﻟﻰ ﺍﻟﺨﻄﺄ‪ .‬ﺭﺍﺟﻊ ﺍﻟﺠﺪﻭﻝ ﺍﻟﺘﺎﻟﻲ ﻟﻠﺘﻌﺮﻑ ﻋﻠﻰ ﻭﺻﻒ ﻛﻞ ﺧﻄﺄ‬
‫ﺣﺴﺐ ﻣﺼﺎﺑﻴﺢ ‪.LED‬‬
‫‪LED2‬‬
‫‪LED1‬‬
‫ﻣﺨﻄﻂ ‪LED‬‬
‫‪LED2 LED1‬‬
‫ﻣﺤﺘﻮﻳﺎﺕ ﺍﻟﺨﻄﺄ‬
‫ﻭﻣﻴﺾ‬
‫ﻭﻣﻴﺾ‬
‫ﺧﻄﺄ ﻓﻲ ﺍﻟﻤﻮﺩﻳﻞ ﺃﻭ ﺧﻄﺄ ‪EEPROM‬‬
‫‪ ١‬ﻣﺮﺓ ﻭﻣﻴﺾ‬
‫ﺇﺿﺎءﺓ‬
‫ﺧﻄﺄ ﻓﻲ ﺗﻮﺻﻴﻞ ﻣﺼﺪﺭ ﺍﻟﻄﺎﻗﺔ‬
‫‪ ٢‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﺇﺿﺎءﺓ‬
‫ﺧﻄﺄ ﻓﻲ ﻣﺴﺘﺸﻌﺮ ﺣﺮﺍﺭﺓ ﺍﻟﺘﻔﺮﻳﻎ‬
‫‪ ٣‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﺇﺿﺎءﺓ‬
‫ﺧﻄﺄ ﻓﻲ ﻣﺴﺘﺸﻌﺮ ﺣﺮﺍﺭﺓ ﺍﻟﻤﺒﺎﺩﻝ ﺍﻟﺤﺮﺍﺭﻱ‬
‫‪ ٤‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﺇﺿﺎءﺓ‬
‫ﺧﻄﺄ ﻓﻲ ﻣﺴﺘﺸﻌﺮ ﺣﺮﺍﺭﺓ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‬
‫‪ ٥‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﺇﺿﺎءﺓ‬
‫ﺧﻄﺄ ﻓﻲ ﺇﺷﺎﺭﺓ ﺍﻻﺗﺼﺎﻝ‬
‫‪ ٦‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﺇﺿﺎءﺓ‬
‫ﺧﻄﺄ ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‬
‫‪ ٧‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﺇﺿﺎءﺓ‬
‫ﺧﻄﺄ ﻓﻲ ﺣﺮﺍﺭﺓ ﺍﻟﺘﻔﺮﻳﻎ‬
‫‪ ٨‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﺇﺿﺎءﺓ‬
‫ﺧﻄﺄ ﺿﻐﻂ ﻋﺎﻟﻲ‬
‫‪ ٩‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﺇﺿﺎءﺓ‬
‫ﺧﻄﺄ ﻓﻲ ﺣﺮﺍﺭﺓ ﺍﻟﻀﺎﻏﻂ‬
‫‪ ١٠‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﺇﺿﺎءﺓ‬
‫ﺧﻄﺄ ﻓﻲ ﻣﺴﺘﺸﻌﺮ ﺣﺮﺍﺭﺓ ﺍﻟﻀﺎﻏﻂ‬
‫‪ ٥‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﻋﺪﻡ ﺍﻹﺿﺎءﺓ‬
‫ﺧﻄﺄ ﻓﻲ ﺣﺮﺍﺭﺓ ﺍﻟﺘﻔﺮﻳﻎ )‪ ٢٤‬ﺳﺎﻋﺔ(‬
‫‪ ٦‬ﻣﺮﺍﺕ ﻭﻣﻴﺾ‬
‫ﻋﺪﻡ ﺍﻹﺿﺎءﺓ‬
‫ﺧﻄﺄ ﺿﻐﻂ ﻋﺎﻟﻲ )‪ ٢٤‬ﺳﺎﻋﺔ(‬
‫ﻋﺪﻡ ﺍﻹﺿﺎءﺓ‬
‫ﻻ ﻳﻮﺟﺪ ﺧﻄﺄ‪ .‬ﺗﺸﻐﻴﻞ ﺍﻟﺤﻤﺎﻳﺔ‬
‫ﻋﻨﺪ ﺇﺻﻼﺡ ﺍﻟﺨﻄﺄ‪ ،‬ﻳﻨﻄﻔﺊ ﻣﺼﺒﺎﺡ ‪.LED‬‬
‫ﻟﻜﻦ‪ ،‬ﺑﺎﻟﻨﺴﺒﺔ ﻟﺘﻔﺮﻳﻎ ﺧﻄﺄ ﺣﺮﺍﺭﺓ ﺍﻷﻧﺒﻮﺏ ﻭﺧﻄﺄ ﺿﻐﻂ ﻋﺎﻟﻲ‪ ،‬ﻳﻀﻲء ﻣﺼﺒﺎﺡ ‪ LED‬ﺑﺎﺳﺘﻤﺮﺍﺭ ﻟﻤﺪﺓ ‪ ٢٤‬ﺳﺎﻋﺔ‪ ،‬ﻃﺎﻟﻤﺎ ﻟﻢ ﻳﺘﻢ‬
‫ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺍﻟﻄﺎﻗﺔ‪.‬‬
‫‪ .٩‬ﻋﻤﻠﻴﺔ ﺍﻟﻀﺦ ﺍﻟﺴﻔﻠﻲ‬
‫ﺗﺤﺬﻳﺮ‬
‫ﺃﺛﻨﺎء ﻋﻤﻠﻴﺔ ﺍﻟﻀﺦ ﺍﻟﺴﻔﻠﻲ‪ ،‬ﺍﺣﺮﺹ ﻋﻠﻰ ﺇﻳﻘﺎﻑ ﺍﻟﻀﺎﻏﻂ ﻗﺒﻞ ﺃﻥ ﺗﻨﺰﻉ ﺍﻧﺎﺑﻴﺐ ﺍﻟﻤﺒﺮﺩ‪ .‬ﻻ ﻗﻢ ﺑﺈﺯﺍﻟﺔ ﺃﻧﺒﻮﺏ ﺍﻟﺘﻮﺻﻴﻞ ﺃﺛﻨﺎء ﻋﻤﻞ‬
‫ﺍﻟﻀﺎﻏﻂ ﻭﻓﺘﺢ ﺍﻟﺼﻤﺎﻡ ﺛﻨﺎﺋﻲ ﺃﻭ ﺛﻼﺛﻲ ﺍﻻﺗﺠﺎﻩ‪ .‬ﻗﺪ ﻳﺘﺴﺒﺐ ﻫﺬﺍ ﻓﻲ ﺗﻜﻮﻥ ﺿﻐﻂ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﻓﻲ ﺩﻭﺭﺓ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺍﻷﻣﺮ ﺍﻟﺬﻱ ﻳﺆﺩﻱ‬
‫ﺑﺪﻭﺭﻩ ﺇﻟﻰ ﺣﺪﻭﺙ ﺗﺴﺮﻳﺐ ﺃﻭ ﺍﻟﺘﻌﺮﺽ ﻹﺻﺎﺑﺎﺕ‪.‬‬
‫ﻟﺘﻔﺎﺩﻱ ﺗﻔﺮﻳﻎ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻓﻲ ﺍﻟﻬﻮﺍء ﻋﻨﺪ ﺗﻐﻴﻴﺮ ﻣﻮﺿﻊ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء ﺃﻭ ﺍﻟﺘﺨﻠﺺ ﻣﻨﻪ‪ ،‬ﻗﻢ ﺑﺎﺳﺘﺮﺩﺍﺩ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻣﻦ ﺧﻼﻝ ﺇﺟﺮﺍء‬
‫ﻋﻤﻠﻴﺔ ﺗﺒﺮﻳﺪ ﺃﻭ ﻋﻤﻠﻴﺔ ﺗﺒﺮﻳﺪ ﺇﺟﺒﺎﺭﻱ ً‬
‫ﻭﻓﻘﺎ ﻓﻺﺟﺮﺍء ﺍﻟﺘﺎﻟﻲ‪) .‬ﻋﻨﺪ ﺗﻌﺬﺭ ﺇﺟﺮﺍء ﻋﻤﻠﻴﺔ ﺗﺒﺮﻳﺪ ﻓﻲ ﺍﻟﺸﺘﺎء ﻭﻣﺎ ﺷﺎﺑﻪ‪ ،‬ﻗﻢ ﺑﺒﺪء ﻋﻤﻠﻴﺔ‬
‫ﺍﻟﺘﺒﺮﻳﺪ ﺍﻹﺟﺒﺎﺭﻱ‪(.‬‬
‫)‪ (١‬ﻗﻢ ﺑﺈﺧﺮﺍﺝ ﺍﻟﻬﻮﺍء ﻣﻦ ﺧﺮﻃﻮﻡ ﺍﻟﺘﻔﺮﻳﻎ ﻣﻦ ﺧﻼﻝ ﺗﻮﺻﻴﻞ ﺧﺮﻃﻮﻡ ﺍﻟﺘﻔﺮﻳﻎ ﺍﻟﺨﺎﺹ ﺑﻤﺸﻌﺐ ﺍﻟﻌﺪﺍﺩﺍﺕ ﺑﻤﻨﻔﺬ ﺍﻟﺘﻔﺮﻳﻎ‬
‫ﺑﺎﻟﺼﻤﺎﻡ ﺛﻼﺛﻲ ﺍﻻﺗﺠﺎﻩ )ﺍﻟﻜﺒﻴﺮ( ﻭﻓﺘﺢ ﺻﻤﺎﻡ ﺍﻟﻀﻐﻂ ﺍﻟﻤﻨﺨﻔﺾ ﺑﺒﻂء‪.‬‬
‫)‪ (٢‬ﻗﻢ ﺑﺈﻏﻼﻕ ﻣﻨﻔﺬ ﺍﻟﺼﻤﺎﻡ ﺛﻨﺎﺋﻲ ﺍﻻﺗﺠﺎﻩ )ﺍﻟﺼﻐﻴﺮ( ﺑﺎﻟﻜﺎﻣﻞ‪.‬‬
‫)‪ (٣‬ﺍﺑﺪﺃ ﺗﺸﻐﻴﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺃﻭ ﺗﺸﻐﻴﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻹﺟﺒﺎﺭﻱ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ ﺩﻟﻴﻞ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪.‬‬
‫)‪ (٤‬ﻗﻢ ﺑﺈﻏﻼﻕ ﻣﻨﻔﺬ ﺍﻟﺼﻤﺎﻡ ﺛﻼﺛﻲ ﺍﻻﺗﺠﺎﻩ )ﺍﻟﻜﺒﻴﺮ( ﻋﻨﺪﻣﺎ ﺗﺼﺒﺢ ﺍﻟﻘﺮﺍءﺓ ﻋﻠﻰ ﻋﺪﺍﺩ ﺍﻟﻀﻐﻂ ﺍﻟﻤﺮﻛﺐ ‪ ٠~٠٫٠٥‬ﻣﻴﺠﺎ‬
‫ﺑﺎﺳﻜﺎﻝ )‪ ٠ ~ ٠٫٥‬ﻛﺠﻢ‪/‬ﺳﻢ‪.(٢‬‬
‫)‪ (٥‬ﺃﻭﻗﻒ ﺍﻟﺘﺸﻐﻴﻞ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﻤﻮﺻﻮﻑ ﻓﻲ ﺩﻟﻴﻞ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‪.‬‬
‫‪Ar-٩‬‬
‫‪29/3/2559 8:43:29‬‬
‫‪9381069118_IM_AR.indd 9‬‬
‫ﺃﻗﺼﻰ ﻃﻮﻝ ﻟﻠﺴﻠﻚ‪ :‬ﺃﺿﺒﻂ ﺍﻟﻄﻮﻝ ﺑﺤﻴﺚ ﻳﻜﻮﻥ ﺍﻧﺨﻔﺎﺽ ﺍﻟﻔﻮﻟﻄﻴﺔ ﺃﻗﻞ ﻣﻦ ‪ .٪٢‬ﺯﻳﺎﺩﺓ ﻗﻄﺮ ﺍﻟﺴﻠﻚ ﺍﻟﻘﻄﺮ ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ ﻃﻮﻝ ﺍﻟﺴﻠﻚ‬
‫ﻛﺒﻴﺮﺍ‪.‬‬
‫ً‬
‫ﺍﻟﻘﺎﻃﻊ‬
‫ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‬
‫ﻗﺎﻃﻊ ﺍﻟﺪﺍﺋﺮﺓ )ﺍﻟﺘﻴﺎﺭ ﺍﻟﺰﺍﺋﺪ(‬
‫‬
‫*‪٢‬‬
‫ﺍﻟﺘﻴﺎﺭ‪) ٢٠ :‬ﺃﻣﺒﻴﺮ(‬
‫ﻗﺎﻃﻊ ﺗﺴﺮﻳﺐ ﺍﻟﺘﺄﺭﻳﺾ‬
‫ﺗﻴﺎﺭ ﺍﻟﺘﺴﺮﻳﺐ‪ ٣٠ :‬ﻣﻴﻠﻠﻲ ﺃﻣﺒﻴﺮ ‪ ٠٫١‬ﺛﺎﻧﻴﺔ ﺃﻭ ﺃﻗﻞ‬
‫ﺗﺄﺭﻳﺾ‬
‫*‪٣‬‬
‫•‬
‫ﺗﺄﺭﻳﺾ‬
‫ﺇﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ‬
‫*‪ ٢‬ﺣﺪﺩ ﺍﻟﻘﺎﻃﻊ ﺍﻟﻤﻨﺎﺳﺐ ﻟﻠﻤﻮﺍﺻﻔﺎﺕ ﺍﻟﻤﻮﺿﺤﺔ ً‬
‫ﻭﻓﻘﺎ ﻟﻠﻤﻌﺎﻳﻴﺮ ﺍﻟﻮﻃﻨﻴﺔ ﺃﻭ ﺍﻹﻗﻠﻴﻤﻴﺔ‪.‬‬
‫*‪ ٣‬ﺣﺪﺩ ﺍﻟﻘﺎﻃﻊ ﺍﻟﺬﻱ ﻳﻤﻜﻦ ﺃﻥ ﻳﻤﺮ ﻣﻦ ﺧﻼﻟﻪ ﺣﻤﻞ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﺎﻓﻲ‪.‬‬
‫•‬
‫•‬
‫•‬
‫‬
‫‬
‫‪0‬‬
‫‪.‬‬
‫ﻗﺒﻞ ﺑﺪء ﺍﻟﺘﺸﻐﻴﻞ‪ ،‬ﺗﺄﻛﺪ ﺃﻥ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﻲ ﻟﻴﺲ ﻣﻮﺻﻼ ﺑﻜﻞ ﺃﻗﻄﺎﺏ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺃﻭ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪.‬‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺟﻤﻴﻊ ﺍﻷﻋﻤﺎﻝ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻭﻓﻘﺎ ﻟﻠﻤﻌﺎﻳﻴﺮ ﺍﻟﻘﻴﺎﺳﻴﺔ ‪.‬‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺟﻬﺎﺯ ﺍﻟﻘﺎﻃﻊ ﻣﻊ ﻭﺟﻮﺩ ﻓﺠﻮﺓ ﻣﻼﻣﺴﺔ ﻻ ﺗﻘﻞ ﻋﻦ ﺛﻼﺛﺔ ﻣﻢ ﻓﻲ ﻛﻞ ﺍﻷﻗﻄﺎﺏ ﺍﻟﻘﺮﻳﺒﺔ ﻣﻦ ﺍﻟﻮﺣﺪﺓ )ﻓﻲ ﻛﻞ ﻣﻦ ﺍﻟﻮﺣﺪﺓ‬
‫ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ(‬
‫ﻳﺠﺐ ﺃﻥ ﻳﺘﻮﺍﻓﻖ ﺣﺠﻢ ﺍﻟﺴﻠﻚ ﻣﻊ ﺍﻟﺮﻣﺰ ﺍﻟﻤﺤﻠﻲ ﺃﻭ ﺍﻟﻮﻃﻨﻲ ﺍﻟﻤﻌﻤﻮﻝ ﺑﻪ‪.‬‬
‫ﻛﺎﺑﻞ‬
‫ﺍﻟﺘﻮﺻﻴﻞ‬
‫)ﺑﺎﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ(‬
‫ﻛﺒﻞ ﺍﻹﻣﺪﺍﺩ‬
‫ﺑﺎﻟﺘﻴﺎﺭ‬
‫)‪ (٣‬ﺿﻊ ﺣﺎﻣﻞ ﺍﻟﺴﻠﻚ ﻭﺍﻟﻐﻄﺎء ﺍﻟﻄﺮﻓﻲ ﺑﻌﺪ ﺍﻛﺘﻤﺎﻝ ﺍﻟﻌﻤﻞ‪.‬‬
‫‪ ٣ ٥‬ﻃﺮﻳﻘﺔ ﺗﻤﺪﻳﺪ ﺍﻷﺳﻼﻙ‬
‫)‪ (١‬ﻗﻢ ﺑﻨﺰﻉ ﺍﻟﻐﻄﺎء ﺍﻟﻄﺮﻓﻲ ﻭﺣﺎﻣﻞ ﺍﻟﺴﻠﻚ‪.‬‬
‫ﺍﻟﻐﻄﺎء ﺍﻟﻄﺮﻓﻲ‬
‫ﺻﻨﺪﻭﻕ ﺍﻟﺘﺤﻜﻢ‬
‫ﺣﺎﻣﻞ ﺍﻟﺴﻠﻚ‬
‫ﺍﻟﻐﻄﺎء ﺍﻟﻄﺮﻓﻲ‬
‫ﺻﻨﺪﻭﻕ ﺍﻟﺘﺤﻜﻢ‬
‫ﺣﺎﻣﻞ ﺍﻟﺴﻠﻚ‬
‫‪ .٦‬ﺍﻟﺘﺸﻐﻴﻞ ﺍﻹﺧﺘﺒﺎﺭﻱ‬
‫ﻗﻢ ﺑﺘﻨﻔﻴﺬ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻻﺧﺘﺒﺎﺭﻱ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﻤﻮﺻﻮﻑ ﻓﻲ ﺩﻟﻴﻞ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‪.‬‬
‫)‪ (٢‬ﻗﻢ ﺑﺘﻮﺻﻴﻞ ﻛﺒﻞ ﺍﻹﻣﺪﺍﺩ ﺑﺎﻟﺘﻴﺎﺭ ﻭﻛﺒﻞ ﺍﻟﺘﻮﺻﻴﻞ ﺑﺎﻟﻄﺮﻑ‪.‬‬
‫‪L N 1(L)2(N) 3‬‬
‫ﻛﺘﻞ ﻃﺮﻓﻴﺔ‬
‫‪ .٧‬ﻗﺎﺋﻤﺔ ﺍﻟﻔﺤﺺ‬
‫ﺍﻓﺤﺺ ﺍﻟﺒﻨﻮﺩ ﺃﺛﻨﺎء ﺍﻟﺘﺸﻐﻴﻞ ﺍﻻﺧﺘﺒﺎﺭﻱ‪.‬‬
‫ﺻﻨﺪﻭﻕ ﺍﻟﺘﺤﻜﻢ‬
‫ﻫﻞ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺗﺼﺪﺭ ﺃﻱ ﺿﻮﺿﺎء ﻏﻴﺮ ﻃﺒﻴﻌﻴﺔ ﺃﻭ ﺗﻬﺘﺰ ﺑﺸﻜﻞ ﻛﺒﻴﺮ؟‬
‫ﻫﻞ ﻳﻬﺐ ﺍﻟﻬﻮﺍء ﺍﻟﺒﺎﺭﺩ ﺃﻭ ﺍﻟﻬﻮﺍء ﺍﻟﺴﺎﺧﻦ ﻣﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﻓﻘﺎ ﻟﻮﺿﻊ ﺍﻟﺘﺸﻐﻴﻞ؟‬
‫ﻗﻢ ﺑﺘﺸﻐﻴﻞ ﺍﻟﻮﺣﺪﺓ ﻭﻓﻘﺎ ﻟﺪﻟﻴﻞ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻤﻘﺪﻡ ﻣﻊ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‪ ،‬ﻭﺗﺄﻛﺪ ﻣﻦ ﺍﻟﺘﺸﻐﻴﻞ ﺑﺸﻜﻞ ﻃﺒﻴﻌﻲ‪.‬‬
‫ﺣﺎﻣﻞ ﺍﻟﺴﻠﻚ‬
‫ﻛﺒﻞ ﺍﻹﻣﺪﺍﺩ ﺑﺎﻟﺘﻴﺎﺭ‬
‫ﻛﺎﺑﻞ ﺍﻟﺘﻮﺻﻴﻞ‬
‫‪ ٣٠~١٥‬ﻣﻢ‬
‫‪ ٤٠‬ﻣﻢ‬
‫‪ ٢٠~١٥‬ﻣﻢ‬
‫‪ ٣٥‬ﻣﻢ‬
‫‪Ar-٨‬‬
‫‪29/3/2559 8:43:30‬‬
‫‪9381069118_IM_AR.indd 8‬‬
‫ﻛﻤﻴﺔ ﺍﻟﺸﺤﻦ ﺍﻹﺿﺎﻓﻲ‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻳﺘﻢ ﺷﺤﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﺍﻟﻤﺼﻨﻊ ﺑﻤﺎﺩﺓ ﺗﺒﺮﻳﺪ ﻣﻨﺎﺳﺒﺔ ﻷﻧﺒﻮﺏ ﺑﻄﻮﻝ ‪ ٧٫٥‬ﻡ‪.‬‬
‫ﺇﺫﺍ ﺗﺠﺎﻭﺯ ﻃﻮﻝ ﺍﻷﻧﺒﻮﺏ ‪ ٧٫٥‬ﻡ‪ ،‬ﻓﻴﺠﺐ ﺇﺟﺮﺍء ﺷﺤﻦ ﺇﺿﺎﻓﻲ‪.‬‬
‫ﻭﺑﺎﻟﻨﺴﺒﺔ ﻟﻤﻘﺪﺍﺭ ﺍﻟﺸﺤﻦ ﺍﻹﺿﺎﻓﻲ ﺍﻟﻤﻼﺋﻢ‪ ،‬ﺍﻧﻈﺮ ﺍﻟﺠﺪﻭﻝ ﺃﺩﻧﺎﻩ‪.‬‬
‫ﺗﻜﻮﻥ ﻗﺪﺭﺓ ﻣﺼﺪﺭ ﺍﻟﺘﻴﺎﺭ ﺍﻟﺮﺋﻴﺴﻲ ﺧﺎﺻﺔ ﺑﻤﻜﻴﻒ ﺍﻟﻬﻮﺍء ﻧﻔﺴﻪ‪ ،‬ﻭﻻ ﺗﺸﻤﻞ ﺍﻻﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﺘﺰﺍﻣﻦ ﻷﺟﻬﺰﺓ ﺃﺧﺮﻯ‪.‬‬
‫ﻻ ﺗﺒﺪﺃ ﺍﻟﺘﺸﻐﻴﻞ ﺣﺘﻰ ﻳﺘﻢ ﺷﺤﻦ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺑﺎﻟﻜﺎﻣﻞ‪ .‬ﺳﻮﻑ ﻳﺘﻌﻄﻞ ﺍﻟﻀﺎﻏﻂ ﻓﻲ ﺣﺎﻟﺔ ﺗﺸﻐﻴﻠﻪ ﻗﺒﻞ ﺍﺳﺘﻜﻤﺎﻝ ﺷﺤﻦ ﺍﻷﻧﺎﺑﻴﺐ ﺑﺴﺎﺋﻞ‬
‫ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫ﻃﻮﻝ ﺍﻷﻧﺒﻮﺏ‬
‫ﺃﻗﻞ ﻣﻦ‬
‫‪ ٧٫٥‬ﻡ‬
‫‪ ١٠‬ﻣﺘﺮ‬
‫‪ ٢٠‬ﻣﺘﺮ‬
‫ﺟﻢ‪/‬ﻡ‬
‫ﻛﻤﻴﺔ ﺷﺤﻦ ﺇﺿﺎﻓﻴﺔ‬
‫ﻻ ﺷﻲء‬
‫‪ ٥٠‬ﺟﻢ‬
‫‪ ٢٥٠‬ﺟﻢ‬
‫‪ ٢٠‬ﺟﻢ‪/‬ﻡ‬
‫ﻳﻜﻮﻥ ﺟﻬﺪ ﻛﺒﻞ ﺍﻟﻨﻘﻞ ﺑﻴﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ‪ ٢٣٠‬ﻓﻮﻟﺖ‪.‬‬
‫ﺗﺄﻛﺪ ﻣﻦ ﻋﺪﻡ ﺇﺯﺍﻟﺔ ﻣﺴﺘﺸﻌﺮ ﺍﻟﻤﻘﺎﻭﻡ ﺍﻟﺤﺮﺍﺭﻱ ﻭﻏﻴﺮﻩ ﻣﻦ ﺳﻠﻚ ﺍﻟﻄﺎﻗﺔ ﻭﺃﺳﻼﻙ ﺍﻟﺘﻮﺻﻴﻞ‪ .‬ﻗﺪ ﻳﺘﻌﻄﻞ ﺍﻟﻀﺎﻏﻂ ﻓﻲ ﺣﺎﻟﺔ ﺗﺸﻐﻴﻠﻪ‬
‫ﺃﺛﻨﺎء ﺇﺯﺍﻟﺔ ﺍﻟﻤﺴﺘﺸﻌﺮ‪.‬‬
‫ﺍﺑﺪﺃ ﺗﻮﺻﻴﻼﺕ ﺍﻷﺳﻼﻙ ﺑﻌﺪ ﺇﻏﻼﻕ ﻣﻔﺘﺎﺡ ﺍﻟﻔﺮﻉ ﻭﻗﺎﻃﻊ ﺍﻟﺘﻴﺎﺭ ﺍﻟﺰﺍﺋﺪ‪.‬‬
‫ﻧﻈﺮﺍ ﻷﻧﻪ ﻳﺘﻢ ﺍﻟﺘﺤﻜﻢ ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺑﻮﺍﺳﻄﺔ‬
‫ﺍﺳﺘﺨﺪﻡ ﻗﺎﻃﻊ ﺍﻟﺘﺴﺮﻳﺐ ﺍﻷﺭﺿﻲ ﺍﻟﻘﺎﺩﺭ ﻋﻠﻰ ﺍﻟﺘﻌﺎﻣﻞ ﻣﻊ ﺍﻟﺘﺮﺩﺩﺍﺕ ﺍﻟﻌﺎﻟﻴﺔ‪ً .‬‬
‫ﻋﺎﻛﺲ‪ ،‬ﻳﻠﺰﻡ ﺍﺳﺘﺨﺪﺍﻡ ﻗﺎﻃﻊ ﺗﺴﺮﻳﺐ ﺃﺭﺿﻲ ﻋﺎﻟﻲ ﺍﻟﺘﺮﺩﺩ ﻟﻤﻨﻊ ﺗﻌﻄﻞ ﺍﻟﻘﺎﻃﻊ ﻧﻔﺴﻪ‪.‬‬
‫‪ ٨ ٤‬ﻓﺤﺺ ﺗﺴﺮﺏ ﺍﻟﻐﺎﺯ‬
‫ﺧﺼﻴﺼﺎ ﻟﻠﺤﻤﺎﻳﺔ ﻣﻦ ﺗﻌﻄﻞ )ﺍﻟﺘﺄﺭﻳﺾ(‪ ،‬ﻓﺘﺄﻛﺪ ﻣﻦ ﺗﺮﻛﻴﺐ ﻣﻔﺘﺎﺡ ﻣﺠﻬﺰ ﺑﻤﺼﻬﺮ ﺃﻭ‬
‫ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ ﻗﺎﻃﻊ ﺗﺴﺮﻳﺐ ﺃﺭﺿﻲ ﻣﺼﻤﻢ‬
‫ً‬
‫ﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ‪.‬‬
‫ﺗﻨﺒﻴﻪ‬
‫ﺑﻌﺪ ﺗﻮﺻﻴﻞ ﺍﻷﻧﺎﺑﻴﺐ‪ ،‬ﻗﻢ ﺑﻔﺤﺺ ﺍﻟﻤﻔﺎﺻﻞ ﻟﻠﺘﺤﻘﻖ ﻣﻦ ﺗﺴﺮﺏ ﺍﻟﻐﺎﺯ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﻜﺘﺸﻒ ﺗﺴﺮﺏ ﺍﻟﻐﺎﺯ‪.‬‬
‫ﻻ ﺗﻘﻢ ﺑﺘﻮﺻﻴﻞ ﻣﺼﺪﺭ ﺇﻣﺪﺍﺩ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻤﺘﺮﺩﺩ ﺑﻠﻮﺣﺔ ﻃﺮﻑ ﺧﻂ ﺍﻟﻨﺎﻗﻞ‪ .‬ﻳﻤﻜﻦ ﺃﻥ ﺗﺆﺩﻱ ﺗﻮﺻﻴﻼﺕ ﺍﻷﺳﻼﻙ ﻏﻴﺮ ﺍﻟﺼﺤﻴﺢ ﺇﻟﻰ ﺗﻠﻒ‬
‫ﺍﻟﻨﻈﺎﻡ ﺑﺄﻛﻤﻠﻪ‪.‬‬
‫ﻻ ﺗﺴﺘﺨﺪﻡ ﺃﺳﻼﻙ ﻣﺼﺪﺭ ﻃﺎﻗﺔ ﻣﺘﻘﺎﻃﻌﺔ ﻣﻊ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪.‬‬
‫ﺇﺫﺍ ﻛﺎﻧﺖ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﻤﺤﻴﻄﺔ ﺑﻘﺎﻃﻊ ﺍﻟﺪﺍﺋﺮﺓ ﻣﺮﺗﻔﻌﺔ ﺟ ًﺪﺍ‪ ،‬ﻓﺈﻥ ﺷﺪﺓ ﺍﻷﻣﺒﻴﺮ ﺍﻟﺘﻲ ﻳﻘﻮﻡ ﻋﻨﺪﻫﺎ ﺍﻟﻘﺎﻃﻊ ﺑﻔﺼﻞ ﺍﻟﺘﻴﺎﺭ ﻗﺪ ﺗﻨﺨﻔﺾ‪.‬‬
‫ﺗﺤﺬﻳﺮ‬
‫ﺃﺛﻨﺎء ﻋﻤﻠﻴﺔ ﺍﻟﺘﺮﻛﻴﺐ‪ ،‬ﺍﺣﺮﺹ ﻋﻠﻰ ﺃﻥ ﻳﻜﻮﻥ ﺃﻧﺒﻮﺏ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻣﺜﺒﺘﺎً ﺑﺈﺣﻜﺎﻡ ﻗﺒﻞ ﺗﺸﻐﻴﻞ ﺍﻟﻀﺎﻏﻂ‪.‬‬
‫ﻻ ﺗﻘﻢ ﺑﺘﺸﻐﻴﻞ ﺍﻟﻀﺎﻏﻂ ﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﺗﺮﻛﻴﺐ ﺃﻧﺎﺑﻴﺐ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺑﺸﻜﻞ ﺻﺤﻴﺢ ﺃﺛﻨﺎء ﻓﺘﺢ ﺍﻟﺼﻤﺎﻡ ﺛﻨﺎﺋﻲ ﺃﻭ ﺛﻼﺛﻲ ﺍﻻﺗﺠﺎﻩ‪ .‬ﻗﺪ‬
‫ﻳﺘﺴﺒﺐ ﻫﺬﺍ ﻓﻲ ﺗﻜﻮﻥ ﺿﻐﻂ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﻓﻲ ﺩﻭﺭﺓ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺍﻷﻣﺮ ﺍﻟﺬﻱ ﻳﺆﺩﻱ ﺑﺪﻭﺭﻩ ﺇﻟﻰ ﺣﺪﻭﺙ ﺃﻋﻄﺎﻝ ﺃﻭ ﻭﻗﻮﻉ ﺇﺻﺎﺑﺎﺕ‪.‬‬
‫ﺃﺛﻨﺎء ﻋﻤﻠﻴﺔ ﺍﻟﻀﺦ ﺍﻟﺴﻔﻠﻲ‪ ،‬ﺍﺣﺮﺹ ﻋﻠﻰ ﺇﻳﻘﺎﻑ ﺍﻟﻀﺎﻏﻂ ﻗﺒﻞ ﺃﻥ ﺗﻨﺰﻉ ﺍﻧﺎﺑﻴﺐ ﺍﻟﻤﺒﺮﺩ‪.‬‬
‫ﻻ ﻗﻢ ﺑﺈﺯﺍﻟﺔ ﺃﻧﺒﻮﺏ ﺍﻟﺘﻮﺻﻴﻞ ﺃﺛﻨﺎء ﻋﻤﻞ ﺍﻟﻀﺎﻏﻂ ﻭﻓﺘﺢ ﺍﻟﺼﻤﺎﻡ ﺛﻨﺎﺋﻲ ﺃﻭ ﺛﻼﺛﻲ ﺍﻻﺗﺠﺎﻩ‪.‬‬
‫ﻗﺪ ﻳﺘﺴﺒﺐ ﻫﺬﺍ ﻓﻲ ﺗﻜﻮﻥ ﺿﻐﻂ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﻓﻲ ﺩﻭﺭﺓ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺍﻷﻣﺮ ﺍﻟﺬﻱ ﻳﺆﺩﻱ ﺑﺪﻭﺭﻩ ﺇﻟﻰ ﺣﺪﻭﺙ ﺃﻋﻄﺎﻝ ﺃﻭ ﻭﻗﻮﻉ ﺇﺻﺎﺑﺎﺕ‪.‬‬
‫ﻋﻨﺪ ﺗﺮﻛﻴﺐ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء ﻭﻧﻘﻠﻪ‪ ،‬ﻻ ﻳﺴﻤﺢ ﺑﺨﻠﻂ ﺃﻱ ﻏﺎﺯﺍﺕ ﻭﺩﺧﻮﻟﻬﺎ ﺩﻭﺭﺓ ﺍﻟﺘﺒﺮﻳﺪ ﻏﻴﺮ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ )‪ (R410A‬ﺍﻟﻤﺤﺪﺩﺓ‪.‬‬
‫ﺇﺫﺍ ﺩﺧﻞ ﺍﻟﻬﻮﺍء ﺍﻟﺠﻮﻱ ﺃﻭ ﺃﻱ ﻏﺎﺯ ﺁﺧﺮ ﺇﻟﻰ ﺩﻭﺭﺓ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺳﻴﺮﺗﻔﻊ ﺍﻟﻀﻐﻂ ﺩﺍﺧﻞ ﺍﻟﺪﻭﺭﺓ ﺇﻟﻰ ﺣﺪ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﻣﻤﺎ ﻳﻨﺘﺞ‬
‫ﻋﻨﻪ ﺣﺪﻭﺙ ﺃﻋﻄﺎﻝ ﺃﻭ ﺣﺪﻭﺙ ﺇﺻﺎﺑﺎﺕ ‪...‬ﺍﻟﺦ‪.‬‬
‫ﻛﻴﻔﻴﺔ ﺗﻮﺻﻴﻞ ﺍﻷﺳﻼﻙ ﺑﺄﻃﺮﺍﻑ ﺍﻟﺘﻮﺻﻴﻞ‬
‫ﺗﺤﺬﻳﺮ ﻋﻨﺪ ﺗﺮﻛﻴﺐ ﺍﻷﺳﻼﻙ‬
‫ﻋﻨﺪ ﻧﺰﻉ ﻋﺎﺯﻝ ﺳﻠﻚ ﺭﺻﺎﺻﻲ‪ ،‬ﺍﺳﺘﻌﻤﻞ ﺩﺍﺋﻤﺎ ﺃﺩﺍﺓ ﺧﺎﺻﺔ ﻣﺜﻞ ﻣﻌﺮﺑﺔ ﺍﻷﺳﻼﻙ‪ .‬ﺇﺫﺍ ﻟﻢ ﺗﺘﻮﻓﺮ ﺃﺩﺍﺓ ﺧﺎﺻﺔ‪ ،‬ﻗﻢ ﺑﻨﺰﻉ ﺍﻟﻌﺎﺯﻝ‬
‫ﺑﺴﻜﻴﻨﺔ‪ ،‬ﺃﻭ ﻣﺎ ﺷﺎﺑﻪ‪.‬‬
‫)‪ (١‬ﻗﻢ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺃﻃﺮﺍﻑ ﺩﺍﺋﺮﻳﺔ ﻣﻊ ﺟﻠﺒﺎﺕ ﻋﺎﺯﻟﺔ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ ﺍﻟﺸﻜﻞ ﺃﺩﻧﺎﻩ ﻟﻠﺘﻮﺻﻴﻞ ﺑﻤﺠﻤﻮﻋﺔ ﻃﺮﻑ ﺍﻟﺘﻮﺻﻴﻞ‪.‬‬
‫)‪ (٢‬ﻗﻢ ﺑﺘﺜﺒﻴﺖ ﻃﺮﻑ ﺩﺍﺋﺮﻱ ﺑﺈﺣﻜﺎﻡ ﻣﻊ ﺍﻷﺳﻼﻙ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺃﺩﺍﺓ ﻣﻨﺎﺳﺒﺔ ﺑﺤﻴﺚ ﻻ ﺗﻜﻮﻥ ﺍﻷﺳﻼﻙ ﻣﺮﺗﺨﻴﺔ‪.‬‬
‫ﻣﻌﺮﻯ ‪ ١٠ :‬ﻣﻢ‬
‫ّ‬
‫ﻃﺮﻑ ﺩﺍﺋﺮﻱ‬
‫ﻛﻢ‬
‫‪ .٥‬ﺗﺮﻛﻴﺐ ﺍﻷﺳﻼﻙ ﺍﻟﻜﻬﺮﺑﻴﺔ‬
‫)‪ (٣‬ﺍﺳﺘﻌﻤﻞ ﺍﻷﺳﻼﻙ ﺍﻟﻤﺤﺪﺩﺓ‪ ،‬ﻭﻭﺻﻠﻬﺎ ﺑﺈﺣﻜﺎﻡ‪ ،‬ﻭﺍﺭﺑﻄﻬﺎ ﺑﺤﻴﺚ ﻻ ﻳﻜﻮﻥ ﻫﻨﺎﻙ ﺃﻱ ﺿﻐﻂ ﻋﻠﻰ ﺍﻷﻃﺮﺍﻑ‪.‬‬
‫‪ ١ ٥‬ﻣﻼﺣﻈﺎﺕ ﺧﺎﺻﺔ ﺑﺘﺮﻛﻴﺐ ﺍﻷﺳﻼﻙ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬
‫)‪ (٤‬ﺍﺳﺘﻌﻤﻞ ﻣﻔﻚ ﻣﺴﺎﻣﻴﺮ ﻟﻮﻟﺒﻴﺔ ﻣﻨﺎﺳﺐ ﻟﺸﺪ ﺍﻟﻤﺴﺎﻣﻴﺮ ﺍﻟﻄﺮﻓﻴﺔ‪ .‬ﻻ ﺗﺴﺘﺨﺪﻡ ﻣﻔﻚ ﻣﺴﺎﻣﻴﺮ ﻟﻮﻟﺒﻴﺔ ﺻﻐﻴﺮ ﺟﺪﺍ‪ ،‬ﻭﺇﻻ ﻗﺪ ﺗﺘﻠﻒ‬
‫ﺭﺅﻭﺱ ﺍﻟﻤﺴﺎﻣﻴﺮ ﺍﻟﻠﻮﻟﺒﻴﺔ‪ ،‬ﻣﻤﺎ ﻳﻤﻨﻊ ﻣﻦ ﺷﺪ ﺍﻟﻤﺴﺎﻣﻴﺮ ﺑﺸﻜﻞ ﺻﺤﻴﺢ‪.‬‬
‫)‪ (٥‬ﻻ ﺗﺸﺪﻳﺪ ﺍﻟﻤﺴﺎﻣﻴﺮ ﺍﻟﻄﺮﻓﻴﺔ ﻛﺜﻴﺮﺍ ﺟﺪﺍ‪ ،‬ﻭﺇﻻ ﻗﺪ ﺗﻨﻜﺴﺮ ﺍﻟﻤﺴﺎﻣﻴﺮ ﺍﻟﻠﻮﻟﺒﻴﺔ‪.‬‬
‫ﺑﺮﻏﻲ ﻣﻊ ﻓﻠﻜﺔ ﺧﺎﺻﺔ‬
‫ﺗﺤﺬﻳﺮ‬
‫ﻳﺠﺐ ﻋﻤﻞ ﺗﻮﺻﻴﻼﺕ ﺍﻷﺳﻼﻙ ﺑﻮﺍﺳﻄﺔ ﺷﺨﺺ ﻣﺆﻫﻞ ً‬
‫ﻭﻓﻘﺎ ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪ .‬ﻳﺼﻞ ﻣﻌﺪﻝ ﺍﻟﺠﻬﺪ ﻟﻬﺬﺍ ﺍﻟﻤﻨﺘﺞ ‪ ٢٣٠‬ﻓﻮﻟﺖ ﻋﻨﺪ ‪٦٠‬‬
‫ﻫﺮﺗﺰ‪ .‬ﻭﻳﺠﺐ ﺗﺸﻐﻴﻠﻪ ﺿﻤﻦ ﻧﻄﺎﻕ ‪ ١٩٨‬ﺇﻟﻰ ‪ ٢٥٣‬ﻓﻮﻟﺖ‪.‬‬
‫ﻃﺮﻑ ﺩﺍﺋﺮﻱ‬
‫ﺑﺮﻏﻲ ﻣﻊ ﻓﻠﻜﺔ ﺧﺎﺻﺔ‬
‫ﺳﻠﻚ ﻛﻬﺮﺑﺎﺋﻲ‬
‫ﻃﺮﻑ ﺩﺍﺋﺮﻱ‬
‫ﻗﺒﻞ ﺗﻮﺻﻴﻞ ﺍﻷﺳﻼﻙ‪ ،‬ﺗﺄﻛﺪ ﻣﻦ ﺇﻳﻘﺎﻑ ﻣﺼﺪﺭ ﺇﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ‪.‬‬
‫ﺍﺳﺘﺨﺪﻡ ﺩﺍﺋﺮﺓ ﺇﻣﺪﺍﺩ ﻃﺎﻗﺔ ﻣﺨﺼﺼﺔ‪ .‬ﻗﺪ ﺗﺆﺩﻱ ﻗﺪﺭﺓ ﺍﻟﻄﺎﻗﺔ ﻏﻴﺮ ﺍﻟﻜﺎﻓﻴﺔ ﻓﻲ ﺍﻟﺪﺍﺋﺮﺓ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺃﻭ ﺍﻟﺘﻮﺻﻴﻼﺕ ﻏﻴﺮ ﺍﻟﺼﺤﻴﺤﺔ‬
‫ﻟﻸﺳﻼﻙ ﺇﻟﻰ ﺣﺪﻭﺙ ﺻﺪﻣﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ ﺃﻭ ﺣﺮﻳﻖ‪.‬‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ ﻓﻲ ﻣﺼﺪﺭ ﺇﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ ﻟﻜﻞ ﻭﺣﺪﺓ ﺧﺎﺭﺟﻴﺔ‪ .‬ﻳﻤﻜﻦ ﺃﻥ ﻳﺆﺩﻱ ﺍﺧﺘﻴﺎﺭ ﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ ﻏﻴﺮ ﺻﺤﻴﺢ ﺇﻟﻰ ﺻﺪﻣﺔ‬
‫ﻛﻬﺮﺑﺎﺋﻴﺔ ﺃﻭ ﻧﺸﻮﺏ ﺣﺮﻳﻖ‪.‬‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺘﺴﺮﻳﺐ ً‬
‫ﻭﻓﻘﺎ ﻟﻠﻘﻮﺍﻧﻴﻦ ﻭﺍﻟﻘﻮﺍﻋﺪ ﺍﻟﻤﺘﻌﻠﻘﺔ‪.‬‬
‫ﻳﻤﻜﻦ ﺃﻥ ﻳﺆﺩﻱ ﺍﻟﺼﻨﺪﻭﻕ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﺍﻟﻤﺮﻛﺐ ﺑﺸﻜﻞ ﺧﺎﻃﺊ ﺇﻟﻰ ﺣﻮﺍﺩﺙ ﺧﻄﻴﺮﺓ ﻣﺜﻞ ﺣﺪﻭﺙ ﺻﺪﻣﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ ﺃﻭ ﺣﺮﻳﻖ ﻋﻦ‬
‫ﻃﺮﻳﻖ ﺍﻟﺘﻌﺮﺽ ﻟﻠﻐﺒﺎﺭ ﺃﻭ ﺍﻟﻤﺎء‪.‬‬
‫ﻳﺘﻢ ﺗﺮﻛﻴﺐ ﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ ﻓﻲ ﺗﻮﺻﻴﻼﺕ ﺍﻷﺳﻼﻙ ﺍﻟﺪﺍﺋﻤﺔ‪ .‬ﺍﺣﺮﺹ ﺩﺍﺋﻤًﺎ ﻋﻠﻰ ﺍﺳﺘﺨﺪﺍﻡ ﺩﺍﺋﺮﺓ ﻳﻤﻜﻨﻬﺎ ﺇﻋﺘﺎﻕ ﻛﺎﻓﺔ ﺃﻗﻄﺎﺏ ﺍﻷﺳﻼﻙ‬
‫ﻭﺑﻬﺎ ﻣﺴﺎﻓﺔ ﻋﺰﻝ ﺑﺤﻮﺍﻟﻲ ‪ ٣‬ﻣﻢ ﻋﻠﻰ ﺍﻷﻗﻞ ﺑﻴﻦ ﺃﺟﺰﺍء ﺗﻼﻣﺲ ﻛﻞ ﻗﻄﺐ‪.‬‬
‫ﺍﺳﺘﺨﺪﻡ ﺍﻟﻜﺒﻼﺕ ﺍﻟﻤﺨﺼﺼﺔ ﻭﻛﺒﻼﺕ ﺍﻟﻄﺎﻗﺔ‪ .‬ﻳﻤﻜﻦ ﺃﻥ ﻳﺆﺩﻱ ﺍﻻﺳﺘﺨﺪﺍﻡ ﻏﻴﺮ ﺍﻟﻤﻨﺎﺳﺐ ﺇﻟﻰ ﺻﺪﻣﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ ﺃﻭ ﻧﺸﻮﺏ ﺣﺮﻳﻖ‬
‫ﺑﺴﺒﺐ ﺿﻌﻒ ﺍﻟﺘﻮﺻﻴﻞ ﺃﻭ ﺍﻟﻌﺰﻝ ﻏﻴﺮ ﺍﻟﻜﺎﻓﻲ ﺃﻭ ﺯﻳﺎﺩﺓ ﺍﻟﺘﻴﺎﺭ‪.‬‬
‫ﻛﺘﻞ ﻃﺮﻓﻴﺔ‬
‫ﺳﻠﻚ ﻛﻬﺮﺑﺎﺋﻲ‬
‫)‪ (٦‬ﺍﻧﻈﺮ ﺍﻟﺠﺪﻭﻝ ﺃﺩﻧﺎﻩ ﻟﻤﻌﺮﻓﺔ ﻋﺰﻡ ﺷﺪ ﺍﻟﻤﺴﺎﻣﻴﺮ ﺍﻟﻄﺮﻓﻴﺔ‪.‬‬
‫ﺗﺸﺪﻳﺪ ﻋﺰﻡ ﺍﻟﺪﻭﺭﺍﻥ ] ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )ﻛﺠﻢ ﻗﻮﺓ‪ /‬ﺳﻢ([‬
‫ﻣﺴﻤﺎﺭ ﻟﻮﻟﺒﻲ ‪M4‬‬
‫ﻣﻦ ‪ ١٫٢‬ﺇﻟﻰ ‪) ١٫٨‬ﻣﻦ ‪ ١٢‬ﺇﻟﻰ ‪(١٨‬‬
‫ﻣﺴﻤﺎﺭ ﻟﻮﻟﺒﻲ ‪M5‬‬
‫ﻣﻦ ‪ ٢٫٠‬ﺇﻟﻰ ‪) ٣٫٠‬ﻣﻦ ‪ ٢٠‬ﺇﻟﻰ ‪(٣٠‬‬
‫‪ ٢ ٥‬ﺍﺧﺘﻴﺎﺭ ﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ ﻭﺳﻠﻚ‬
‫ﻻ ﺗﻘﻢ ﺑﺘﻌﺪﻳﻞ ﺳﻠﻚ ﺍﻟﻜﻬﺮﺑﺎء‪ ،‬ﺃﻭ ﺍﺳﺘﺨﺪﻡ ﺳﻠﻚ ﺍﻟﺘﻤﺪﻳﺪ‪ ،‬ﺃﻭ ﺃﺳﻼﻙ ﻓﺮﻋﻴﺔ‪ .‬ﻳﻤﻜﻦ ﺃﻥ ﻳﺘﺴﺒﺐ ﺍﻻﺳﺘﺨﺪﺍﻡ ﻏﻴﺮ ﺍﻟﻤﻨﺎﺳﺐ ﻓﻲ ﺻﺪﻣﺔ‬
‫ﻛﻬﺮﺑﺎﺋﻴﺔ ﺃﻭ ﻧﺸﻮﺏ ﺣﺮﻳﻖ ﻋﻦ ﻃﺮﻳﻖ ﺿﻌﻒ ﺍﻟﺘﻮﺻﻴﻞ ﺃﻭ ﺍﻟﺘﺮﻛﻴﺐ ﻏﻴﺮ ﺍﻟﻤﻨﺎﺳﺐ ﺃﻭ ﺯﻳﺎﺩﺓ ﺍﻟﺘﻴﺎﺭ‪.‬‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻗﻢ ﺑﺘﻮﺻﻴﻞ ﻛﺒﻞ ﺍﻟﺘﻮﺻﻴﻞ ﺑﺎﻟﻄﺮﻑ ﺑﺈﺣﻜﺎﻡ‪ .‬ﺍﻓﺤﺺ ﻣﺤﺎﻣﻞ ﺍﻟﻮﺟﻪ ﺍﻟﻤﻴﻜﺎﻧﻴﻜﻲ ﻓﻲ ﺍﻟﻜﺒﻼﺕ ﺍﻟﻤﺘﺼﻠﺔ ﺑﺎﻷﻃﺮﺍﻑ‪ .‬ﻗﺪ ﻳﺆﺩﻱ ﺍﻟﻌﺰﻝ‬
‫ﺍﻟﺨﺎﻃﺊ ﺇﻟﻰ ﻧﺸﻮﺏ ﺣﺮﻳﻖ‪.‬‬
‫ﺗﺄﻛﺪ ﻣﻦ ﺗﺮﻛﻴﺐ ﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ ﺑﺎﻟﻘﺪﺭﺓ ﺍﻟﻤﺤﺪﺩﺓ‪.‬‬
‫ﺍﺳﺘﺨﺪﻡ ﺃﻃﺮﺍﻑ ﺩﺍﺋﺮﻳﺔ ﻭﺍﺭﺑﻂ ﻣﺴﺎﻣﻴﺮ ﺍﻷﻃﺮﺍﻑ ﺣﺴﺐ ﺍﻟﻌﺰﻡ ﺍﻟﻤﺤﺪﺩ‪ ،‬ﺧﻼﻑ ﺫﻟﻚ ﻗﺪ ﺗﺼﺪﺭ ﺯﻳﺎﺩﺓ ﺳﺨﻮﻧﺔ ﻏﻴﺮ ﻋﺎﺩﻳﺔ ﻭﻗﺪ‬
‫ﺗﺆﺩﻱ ﺇﻟﻰ ﺗﻠﻒ ﺧﻄﻴﺮ ﺩﺍﺧﻞ ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫ﻗﺒﻞ ﺇﺟﺮﺍء ﺃﻋﻤﺎﻝ ﺍﻟﺘﺮﻛﻴﺒﺎﺕ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‪ ،‬ﺗﺄﻛﺪ ﻣﻦ ﺍﻟﻤﻌﺎﻳﻴﺮ ﻭﺍﻟﻠﻮﺍﺋﺢ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻓﻲ ﻛﻞ ﺩﻭﻟﺔ‪ ،‬ﺃﻭ ﻣﻨﻄﻘﺔ‪ ،‬ﺃﻭ ﻣﻜﺎﻥ ﺗﺮﻛﻴﺐ‪ .‬ﺛﻢ‬
‫ﺍﺧﺘﺒﺮ ﺍﻷﺳﻼﻙ ﻭﺍﻟﻘﻮﺍﻃﻊ ﺍﻟﻤﻨﺎﺳﺒﺔ ﺍﻟﺘﻲ ﺗﻤﺘﺜﻞ ﻟﻬﺎ‪.‬‬
‫ﺗﺄﻛﺪ ﻣﻦ ﺗﺎﻣﻴﻦ ﺟﺰء ﺍﻟﻌﺰﻝ ﻓﻲ ﻛﺒﻞ ﺍﻟﻤﻮﺻﻞ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﺸﺒﻚ ﺍﻟﻜﺒﻞ‪ .‬ﻗﺪ ﻳﺆﺩﻱ ﺍﻟﻌﺰﻝ ﺍﻟﺘﺎﻟﻒ ﺇﻟﻰ ﺣﺪﻭﺙ ﺩﺍﺋﺮﺓ ﻗﺼﺮ‪.‬‬
‫ﺛﺒّﺖ ﺍﻷﺳﻼﻙ ﺣﺘﻰ ﻻ ﺗﺘﻼﻣﺲ ﺍﻷﺳﻼﻙ ﻣﻊ ﺍﻷﻧﺎﺑﻴﺐ )ﻭﺧﺼﻮﺻﺎ ﻋﻠﻰ ﺟﺎﻧﺐ ﺍﻟﻀﻐﻂ ﺍﻟﻌﺎﻟﻲ(‪ .‬ﻻ ﺗﺠﻌﻞ ﻛﺒﻞ ﺍﻹﻣﺪﺍﺩ ﺑﺎﻟﺘﻴﺎﺭ ﻭﻛﺒﻞ‬
‫ﺍﻟﻨﻘﻞ ﻳﺘﻼﻣﺲ ﻣﻊ ﺍﻟﺼﻤﺎﻣﺎﺕ )ﺍﻟﻐﺎﺯ(‪.‬‬
‫ً‬
‫ﺗﺠﻨﺐ‬
‫ﻣﻄﻠﻘﺎ ﺗﺮﻛﻴﺐ ﻣﻜﺜﻒ ﺗﺤﺴﺴﻴﻦ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‪ .‬ﻓﺒﺪﻻ ﻣﻦ ﺗﺤﺴﻴﻦ ﻋﺎﻣﻞ ﺍﻟﻄﺎﻗﺔ‪ ،‬ﻗﺪ ﻳﺘﻌﺮﺽ ﺍﻟﻤﻜﺜﻒ ﻟﻠﺴﺨﻮﻧﺔ ﺍﻟﻤﻔﺮﻃﺔ‪.‬‬
‫ﺗﺄﻛﺪ ﻣﻦ ﻋﻤﻞ ﺗﻮﺻﻴﻼﺕ )ﺍﻟﺘﺄﺭﻳﺾ(‪.‬‬
‫ﻻ ﺗﻘﻢ ﺑﺘﻮﺻﻴﻞ ﺃﺳﻼﻙ )ﺍﻟﺘﺄﺭﻳﺾ( ﺑﻤﻮﺍﺳﻴﺮ ﺍﻟﻐﺎﺯ ﺃﻭ ﺃﻧﺎﺑﻴﺐ ﺍﻟﻤﻴﺎﻩ ﺃﻭ ﻗﻀﺒﺎﻥ ﺍﻟﺒﺮﻕ ﺃﻭ ﺃﺳﻼﻙ )ﺍﻟﺘﺄﺭﻳﺾ( ﺍﻟﺨﺎﺻﺔ ﺑﺎﻟﻬﺎﺗﻒ‪.‬‬
‫• ﻗﺪ ﻳﺆﺩﻱ ﺍﻟﺘﻮﺻﻴﻞ ﺑﻤﻮﺍﺳﻴﺮ ﺍﻟﻐﺎﺯ ﺇﻟﻰ ﻧﺸﻮﺏ ﺣﺮﻳﻖ ﺃﻭ ﺍﻧﻔﺠﺎﺭ ﻓﻲ ﺣﺎﻟﺔ ﺗﺴﺮﺏ ﺍﻟﻐﺎﺯ‪.‬‬
‫• ﻻ ﻳﻜﻮﻥ ﺍﻟﺘﻮﺻﻴﻞ ﺑﻤﻮﺍﺳﻴﺮ ﺍﻟﻤﻴﺎﻩ ﻃﺮﻳﻘﺔ ﻓﻌﺎﻟﺔ )ﻟﻠﺘﺄﺭﻳﺾ( ﻓﻲ ﺣﺎﻟﺔ ﺍﺳﺘﺨﺪﺍﻡ ﻣﻮﺍﺳﻴﺮ ‪.PVC‬‬
‫• ﻗﺪ ﻳﺆﺩﻱ ﺍﻟﺘﻮﺻﻴﻞ ﺑﺴﻠﻚ )ﺍﻟﺘﺄﺭﻳﺾ( ﺍﻟﺨﺎﺹ ﺑﺎﻟﻬﺎﺗﻒ ﺃﻭ ﻗﻀﻴﺐ ﺍﻟﺒﺮﻕ ﺇﻟﻰ ﺯﻳﺎﺩﺓ ﺧﻄﻴﺮﺓ ﻏﻴﺮ ﻋﺎﺩﻳﺔ ﻓﻲ ﺍﻟﻘﺪﺭﺓ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬
‫ﻓﻲ ﺣﺎﻟﺔ ﻭﻗﻮﻉ ﻋﺎﺻﻔﺔ ﺭﻋﺪﻳﺔ‪.‬‬
‫ﻗﺪ ﻳﺆﺩﻱ )ﺍﻟﺘﺄﺭﻳﺾ( ﻏﻴﺮ ﺍﻟﺼﺤﻴﺢ ﺇﻟﻰ ﺣﺪﻭﺙ ﺻﺪﻣﺎﺕ ﻛﻬﺮﺑﺎﺋﻴﺔ‪.‬‬
‫ﻣﻌﺪﻝ ﺍﻟﻔﻮﻟﻄﻴﺔ‬
‫‪ ١‬ﻓﺎﺯ ‪ ٢٣٠‬ﻓﻮﻟﺖ )‪ ٦٠‬ﻫﺮﺗﺰ(‬
‫ﻧﻄﺎﻕ ﺍﻟﺘﺸﻐﻴﻞ‬
‫‪ ١٩٨‬ﺇﻟﻰ ‪ ٢٥٣‬ﻓﻮﻟﺖ‬
‫ﺣﺎﻣﻞ ﺍﻟﺴﻠﻚ‬
‫ﺣﺠﻢ ﺍﻟﻤﻮﺻﻞ ]ﻣﻢ‪*[٢‬‬
‫ﻛﺒﻞ ﺇﻣﺪﺍﺩ ﻣﺼﺪﺭ ﺍﻟﺘﻴﺎﺭ‬
‫‪٣٫٠ - ٢٫٥‬‬
‫ﻧﻮﻉ ‪60245 IEC66‬‬
‫ﺳﻠﻚ ﺍﻟﺘﻮﺻﻴﻞ‬
‫‪٢٫٥ - ١٫٥‬‬
‫ﻧﻮﻉ ‪60245 IEC57‬‬
‫‪١‬‬
‫ﺍﻟﻨﻮﻉ‬
‫ﻣﻼﺣﻈﺎﺕ‬
‫‪ ٢‬ﺳﻠﻚ ‪ +‬ﺃﺭﺿﻲ‬
‫‪ ١‬ﻓﺎﺯ ‪ ٢٣٠‬ﻓﻮﻟﺖ‬
‫‪ ٣‬ﺳﻠﻚ ‪ +‬ﺃﺭﺿﻲ‬
‫‪ ١‬ﻓﺎﺯ ‪ ٢٣٠‬ﻓﻮﻟﺖ‬
‫*‪ ١‬ﺍﻟﻌﻴﻨﺔ ﺍﻟﻤﺨﺘﺎﺭﺓ ‪ :‬ﺍﺧﺘﺮ ﻧﻮﻉ ﻭﺣﺠﻢ ﺍﻟﺴﻠﻚ ﺍﻟﺼﺤﻴﺢ ﻭﻓﻘﺎ ﻟﻮﺍﺋﺢ ﺍﻟﺪﻭﻟﺔ ﺃﻭ ﺍﻟﻤﻨﻄﻘﺔ‪.‬‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﻏﻄﺎء ﺍﻟﺼﻨﺪﻭﻕ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﺑﺈﺣﻜﺎﻡ ﻋﻠﻰ ﺍﻟﻮﺣﺪﺓ‪ .‬ﻳﻤﻜﻦ ﺃﻥ ﺗﺆﺩﻱ ﻟﻮﺣﺔ ﺍﻟﺼﻴﺎﻧﺔ ﺍﻟﻤﺮﻛﺒﺔ ﺑﺸﻜﻞ ﺧﺎﻃﺊ ﺇﻟﻰ ﺣﻮﺍﺩﺙ‬
‫ﺧﻄﻴﺮﺓ ﻣﺜﻞ ﺣﺪﻭﺙ ﺻﺪﻣﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ ﺃﻭ ﺣﺮﻳﻖ ﻋﻦ ﻃﺮﻳﻖ ﺍﻟﺘﻌﺮﺽ ﻟﻠﻐﺒﺎﺭ ﺃﻭ ﺍﻟﻤﺎء‪.‬‬
‫‪Ar-٧‬‬
‫‪29/3/2559 8:43:30‬‬
‫‪9381069118_IM_AR.indd 7‬‬
‫ﺃﻧﺒﻮﺏ ﺍﻟﺘﻮﺻﻴﻞ‬
‫‪ ٥ ٤‬ﺍﺧﺘﺒﺎﺭ ﺇﺣﻜﺎﻡ ﺍﻟﺴﺪ‬
‫ﺳﺪﺍﺩﺓ ﻓﺎﺭﻏﺔ‬
‫ﺗﺤﺬﻳﺮ‬
‫ﻣﻔﺘﺎﺡ ﺭﺑﻂ ﺳﺪﺍﺳﻲ ﺍﻷﺿﻼﻉ‬
‫ﻗﺒﻞ ﺗﺸﻐﻴﻞ ﺍﻟﻀﺎﻏﻂ‪ ،‬ﺭﻛﺐ ﺍﻷﻧﺎﺑﻴﺐ ﻭﻭﺻﻠﻬﺎ ﺑﺈﺣﻜﺎﻡ‪.‬‬
‫ﻭﺑﺨﻼﻑ ﺫﻟﻚ‪ ،‬ﺇﺫﺍ ﻟﻢ ﻳﺘﻢ ﺗﺮﻛﻴﺐ ﺍﻷﻧﺎﺑﻴﺐ ﻭﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﺼﻤﺎﻣﺎﺕ ﻣﻔﺘﻮﺣﺔ ﻋﻨﺪ ﺗﺸﻐﻴﻞ ﺍﻟﻀﺎﻏﻂ‪ ،‬ﻳﻤﻜﻦ ﺃﻥ ﻳﺪﺧﻞ ﺍﻟﻬﻮﺍء ﻓﻲ ﺩﻭﺭﺓ‬
‫ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ .‬ﺇﺫﺍ ﺣﺪﺙ ﻫﺬﺍ‪ ،‬ﺳﻴﺼﺒﺢ ﺍﻟﻀﻐﻂ ﻓﻲ ﺩﻭﺭﺓ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻣﺮﺗﻔﻊ ﺑﺸﻜﻞ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﻭﻳﺘﺴﺒﺐ ﻓﻲ ﺗﻠﻒ ﺃﻭ ﺇﺻﺎﺑﺔ‪.‬‬
‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‬
‫ﺍﺳﺘﺨﺪﻡ ﻣﻔﺘﺎﺡ ﺭﺑﻂ ﺳﺪﺍﺳﻲ‬
‫‪ ٤‬ﻣﻢ‪.‬‬
‫ﺧﺮﻃﻮﻡ ﺧﺪﻣﺔ‬
‫ﻣﻊ ﻗﻠﺐ ﺻﻤﺎﻡ‬
‫ﺻﻤﺎﻡ ﺛﻼﺛﻲ‬
‫ﺑﻌﺪ ﺍﻟﺘﺮﻛﻴﺐ‪ ،‬ﺗﺄﻛﺪ ﻣﻦ ﻋﺪﻡ ﻭﺟﻮﺩ ﺗﺴﺮﺏ ﻓﻲ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ .‬ﺇﺫﺍ ﺗﺴﺮﺏ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺇﻟﻰ ﺍﻟﻐﺮﻓﺔ ﻭﺃﺻﺒﺢ ﻣﻌﺮﺽ ﻟﻤﺼﺪﺭ ﻧﺎﺭ‬
‫ﻣﺜﻞ ﻣﺪﻓﺄﺓ ﺑﻤﺮﻭﺣﺔ‪ ،‬ﺃﻭ ﻣﻮﻗﺪ‪ ،‬ﺃﻭ ﻣﻀﺮﻡ‪ ،‬ﻳﻨﺘﺞ ﻏﺎﺯ ﺳﺎﻡ‪.‬‬
‫ﻣﻨﻔﺬ ﺍﻟﺸﺤﻦ‬
‫ﻻ ﺗﻌﺮﺽ ﺍﻷﻧﺎﺑﻴﺐ ﻟﺼﺪﻣﺎﺕ ﻗﻮﻳﺔ ﺧﻼﻝ ﺍﺧﺘﺒﺎﺭ ﺇﺣﻜﺎﻡ ﺍﻟﺴﺪ‪ .‬ﻣﻤﻜﻦ ﺃﻥ ﻳﺆﺩﻱ ﺫﻟﻚ ﺇﻟﻰ ﺗﻤﺰﻕ ﺍﻷﻧﺎﺑﻴﺐ ﺃﻭ ﻳﺘﺴﺒﺐ ﻓﻲ ﺣﺪﻭﺙ‬
‫ﺇﺻﺎﺑﺔ ﺧﻄﻴﺮﺓ‪.‬‬
‫ﺍﻟﺴﺪﺍﺩﺓ‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻻ ﺗﻘﻢ ﺑﺴﺪ ﺍﻟﺠﺪﺭﺍﻥ ﺃﻭ ﺍﻟﺴﻘﻒ ﺣﺘﻰ ﻳﺘﻢ ﺍﻛﺘﻤﺎﻝ ﺍﺧﺘﺒﺎﺭ ﺇﺣﻜﺎﻡ ﺍﻟﺴﺪ ﻭﺷﺤﻦ ﻏﺎﺯ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻷﻏﺮﺍﺽ ﺍﻟﺼﻴﺎﻧﺔ‪ ،‬ﻻ ﺗﻘﻢ ﺑﺪﻓﻦ ﺍﻷﻧﺎﺑﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪.‬‬
‫•‬
‫•‬
‫•‬
‫•‬
‫•‬
‫•‬
‫•‬
‫•‬
‫•‬
‫ﺑﻌﺪ ﺗﻮﺻﻴﻞ ﺍﻷﻧﺎﺑﻴﺐ‪ ،‬ﻗﻢ ﺑﺈﺟﺮﺍء ﺍﺧﺘﺒﺎﺭ ﺇﺣﻜﺎﻡ ﺍﻟﺴﺪ‪.‬‬
‫ﺗﺄﻛﺪ ﻣﻦ ﺃﻥ ﺍﻟﺼﻤﺎﻡ ﺍﻟﺜﻼﺛﻲ ﻣﻐﻠﻖ ﻗﺒﻞ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭ ﺇﺣﻜﺎﻡ ﺍﻟﺴﺪ‪.‬‬
‫ﺗﻜﻴﻴﻒ ﺿﻐﻂ ﻏﺎﺯ ﺍﻟﻨﻴﺘﺮﻭﺟﻴﻦ ﻟﻴﺼﻞ ﺇﻟﻰ ‪ ٤٫١٥‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ ﻹﺟﺮﺍء ﺍﺧﺘﺒﺎﺭ ﺇﺣﻜﺎﻡ ﺍﻟﺴﺪ‪.‬‬
‫ﺇﺿﺎﻓﺔ ﻏﺎﺯ ﺍﻟﻨﻴﺘﺮﻭﺟﻴﻦ ﺇﻟﻰ ﻛﻞ ﻣﻦ ﺃﻧﺎﺑﻴﺐ ﺍﻟﺴﺎﺋﻞ ﻭﺃﻧﺎﺑﻴﺐ ﺍﻟﻐﺎﺯ‪.‬‬
‫ﻓﺤﺺ ﺟﻤﻴﻊ ﺍﻟﺘﻮﺻﻴﻼﺕ ﺍﻟﺘﻮﺳﻴﻌﻴﺔ ﻭﺍﻟﻠﺤﺎﻣﺎﺕ‪ .‬ﺛﻢ ﺍﻟﺘﺄﻛﺪ ﻣﻦ ﻋﺪﻡ ﺍﻧﺨﻔﺎﺽ ﺍﻟﻀﻐﻂ‪.‬‬
‫ﻣﻘﺎﺭﻧﺔ ﺍﻟﻀﻐﻂ ﺑﻌﺪ ﺗﻜﻴﻴﻒ ﺍﻟﻀﻐﻂ ﻭﺟﻌﻠﻪ ﺛﺎﺑﺖ ﻟﻤﺪﺓ ‪ ٢٤‬ﺳﺎﻋﺔ‪ ،‬ﺛﻢ ﺍﻟﺘﺄﻛﺪ ﻣﻦ ﻋﺪﻡ ﺍﻧﺨﻔﺎﺽ ﺍﻟﻀﻐﻂ‪.‬‬
‫* ﻋﻨﺪﻣﺎ ﺗﺘﻐﻴﺮ ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ﺍﻟﻬﻮﺍء ﺍﻟﺨﺎﺭﺟﻲ ﺑﻤﻘﺪﺍﺭ ‪ ٥‬ﺩﺭﺟﺎﺕ ﻣﺌﻮﻳﺔ‪ ،‬ﻳﺘﻐﻴﺮ ﺿﻐﻂ ﺍﻻﺧﺘﺒﺎﺭ ﺑﻤﻘﺪﺍﺭ ‪ ٠٫٠٥‬ﻣﻴﺠﺎ‬
‫ﺑﺎﺳﻜﺎﻝ‪ .‬ﺇﺫﺍ ﺍﻧﺨﻔﺾ ﺍﻟﻀﻐﻂ‪ ،‬ﻗﺪ ﻳﺤﺪﺙ ﺗﺴﺮﺏ ﻓﻲ ﻣﻔﺎﺻﻞ ﺍﻷﻧﺎﺑﻴﺐ‪.‬‬
‫ﻓﻲ ﺣﺎﻝ ﻭﺟﻮﺩ ﺗﺴﺮﺏ‪ ،‬ﻗﻢ ﺑﺈﺻﻼﺣﻪ ﻋﻠﻰ ﺍﻟﻔﻮﺭ ﻭﺃﺟﺮﻱ ﺍﺧﺘﺒﺎﺭ ﺇﺣﻜﺎﻡ ﺍﻟﺴﺪ ﻣﺮﺓ ﺃﺧﺮﻯ‪.‬‬
‫ﺑﻌﺪ ﺍﻻﻧﺘﻬﺎء ﻣﻦ ﺍﺧﺘﺒﺎﺭ ﺇﺣﻜﺎﻡ ﺍﻟﺴﺪ‪ ،‬ﺣﺮﺭ ﻋﺎﺯ ﺍﻟﻨﻴﺘﺮﻭﺟﻴﻦ ﻣﻦ ﻛﻼ ﺍﻟﺼﻤﺎﻣﻴﻦ‪.‬‬
‫ﺣﺮﺭ ﻏﺎﺯ ﺍﻟﻨﻴﺘﺮﻭﺟﻴﻦ ﺑﺒﻂء‪.‬‬
‫ﺍﺳﺘﺨﺪﻡ ﻣﺸﻌﺐ ﻋﺪﺍﺩﺍﺕ ﻧﻈﻴﻒ ﻭﺧﺮﻃﻮﻡ‬
‫ﺷﺤﻦ ﻣﻦ ﺃﺟﻞ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪ R410A‬ﻓﻘﻂ‪.‬‬
‫ﻣﺸﻌﺐ ﺍﻟﻌﺪﺍﺩﺍﺕ‬
‫‪ ٦ ٤‬ﻋﻤﻠﻴﺔ ﺗﻔﺮﻳﻎ ﺍﻟﻬﻮﺍء‬
‫ﻣﻀﺨﺔ ﺍﻟﻬﻮﺍء‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻗﻢ ﺑﺎﺧﺘﺒﺎﺭ ﺗﺴﺮﺏ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ )ﺍﺧﺘﺒﺎﺭ ﺇﺣﻜﺎﻡ ﺍﻟﻬﻮﺍء( ﻟﻔﺤﺺ ﺍﻟﺘﺴﺮﺏ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻏﺎﺯ ﺍﻟﻨﻴﺘﺮﻭﺟﻴﻦ ﺃﺛﻨﺎء ﺇﻏﻼﻕ ﺟﻤﻴﻊ ﺍﻟﺼﻤﺎﻣﺎﺕ‬
‫ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪) .‬ﺍﺳﺘﺨﺪﺍﻡ ﺿﻐﻂ ﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﻤﻮﺿﺢ ﻓﻲ ﻻﻓﺘﺔ ﺍﻻﺳﻢ(‬
‫ﺗﺄﻛﺪ ﻣﻦ ﺗﻔﺮﻳﻎ ﻧﻈﺎﻡ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﻀﺨﺔ ﺗﻔﺮﻳﻎ ﻫﻮﺍء‪.‬‬
‫ﺧﺮﻃﻮﻡ ﺧﺪﻣﺔ‬
‫ﻗﺪ ﻻ ﻳﺮﺗﻔﻊ ﺿﻐﻂ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻓﻲ ﺑﻌﺾ ﺍﻷﺣﻴﺎﻥ ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ ﺍﻟﺼﻤﺎﻡ ﺍﻟﻤﻐﻠﻖ ﻣﻔﺘﻮﺣﺎ ﺑﻌﺪ ﺗﻔﺮﻳﻎ ﺍﻟﻨﻈﺎﻡ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﻀﺨﺔ ﺗﻔﺮﻳﻎ‬
‫ﻫﻮﺍء‪ .‬ﻳﺤﺪﺙ ﻫﺬﺍ ﻧﺘﻴﺠﺔ ﺇﻏﻼﻕ ﻧﻈﺎﻡ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻋﻦ ﻃﺮﻳﻖ ﺻﻤﺎﻡ ﺍﻟﺘﻮﺳﻴﻊ ﺍﻹﻟﻜﺘﺮﻭﻧﻲ‪ .‬ﻟﻦ ﻳﺆﺛﺮ ﻫﺬﺍ‬
‫ﻋﻠﻰ ﺗﺸﻐﻴﻞ ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫‪ ٧ ٤‬ﺍﻟﺸﺤﻦ ﺍﻹﺿﺎﻓﻲ‬
‫ﻛﺎﻑ‪ ،‬ﻳﻨﺨﻔﺾ ﺃﺩﺍﺅﻩ‪.‬‬
‫ﺇﺫﺍ ﻟﻢ ﻳﺘﻢ ﺗﻔﺮﻳﻎ ﺍﻟﻨﻈﺎﻡ ﺑﺸﻜﻞ ٍ‬
‫ﺍﺳﺘﺨﺪﻡ ﻣﺸﻌﺐ ﻋﺪﺍﺩﺍﺕ ﻧﻈﻴﻒ ﻭﺧﺮﻃﻮﻡ ﺷﺤﻦ ﻣﻦ ﺃﺟﻞ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪ R410A‬ﻓﻘﻂ‪ .‬ﺍﻋﻠﻢ ﺃﻥ ﺍﺳﺘﺨﺪﺍﻡ ﻧﻔﺲ ﻣﻀﺨﺔ ﺗﻔﺮﻳﻎ‬
‫ﺍﻟﻬﻮﺍء ﻣﻊ ﻣﻮﺍﺩ ﻣﺒﺮﺩﺓ ﺃﺧﺮﻯ ﻗﺪ ﻳﺘﺴﺒﺐ ﻓﻲ ﺗﺤﻄﻴﻢ ﺍﻟﻤﻀﺨﺔ ﺃﻭ ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫ﻻ ﺗﻘﻢ ﺑﺘﻨﻈﻴﻒ ﺍﻟﻬﻮﺍء ﺑﺎﺳﺘﻌﻤﺎﻝ ﺳﻮﺍﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺑﻞ ﻗﻢ ﺑﺎﺳﺘﻌﻤﺎﻝ ﻣﻀﺨﺔ ﺍﻟﻬﻮﺍء ﻟﺘﻔﺮﻳﻎ ﺍﻟﻨﻈﺎﻡ‪.‬‬
‫)‪(١‬‬
‫)‪(٢‬‬
‫)‪(٣‬‬
‫)‪(٤‬‬
‫)‪(٥‬‬
‫)‪(٦‬‬
‫)‪(٧‬‬
‫ﺗﺄﻛﺪ ﻣﻦ ﺃﻥ ﺍﻟﺼﻤﺎﻣﺎﺕ ﻣﻐﻠﻘﺔ ﻋﻦ ﻃﺮﻳﻖ ﺇﺯﺍﻟﺔ ﺍﻟﺴﺪﺍﺩﺍﺕ ﺍﻟﻔﺎﺭﻏﺔ ﻣﻦ ﺃﻧﺎﺑﻴﺐ ﺍﻟﻐﺎﺯ ﻭﺍﻟﺴﺎﺋﻞ‪.‬‬
‫ﻗﻢ ﺑﻨﺰﻉ ﺳﺪﺍﺩﺓ ﻣﻨﻔﺬ ﺍﻟﺸﺤﻦ ﺛﻢ ﻗﻢ ﺑﺘﻮﺻﻴﻞ ﻣﺸﻌﺐ ﺍﻟﻌﺪﺍﺩﺍﺕ ﻭﻣﻀﺨﺔ ﺍﻟﻬﻮﺍء ﺇﻟﻰ ﺻﻤﺎﻡ ﺍﻟﺸﺤﻦ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺧﺮﺍﻃﻴﻢ ﺍﻟﺼﻴﺎﻧﺔ‪.‬‬
‫ﻗﻢ ﺑﺘﻔﺮﻳﻎ ﻫﻮﺍء ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺃﻧﺎﺑﻴﺐ ﺍﻟﺘﻮﺻﻴﻞ ﺇﻟﻰ ﺃﻥ ﻳﻨﺨﻔﺾ ﺍﻟﻀﻐﻂ ﺇﻟﻰ ﺃﻗﻞ ﻣﻦ ‪ -٠٫١‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ )‪ -٧٦‬ﺳﻢ ﺯﺋﺒﻖ(‪.‬‬
‫ﻋﻨﺪ ﺍﻟﻮﺻﻮﻝ ﺇﻟﻰ ‪ -٠٫١‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ )‪ -٧٦‬ﺳﻢ ﺯﺋﺒﻖ(‪ ،‬ﻗﻢ ﺑﺘﺸﻐﻴﻞ ﻣﻀﻐﺔ ﺗﻔﺮﻳﻎ ﺍﻟﻬﻮﺍء ﻟﻤﺪﺓ ‪ ٦٠‬ﺩﻗﻴﻘﺔ ﻋﻠﻰ ﺍﻷﻗﻞ‪.‬‬
‫ﻗﻢ ﺑﻔﺼﻞ ﺧﺮﺍﻃﻴﻢ ﺍﻟﺼﻴﺎﻧﺔ ﺛﻢ ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺳﺪﺍﺩﺓ ﻣﻨﻔﺬ ﺍﻟﺸﺤﻦ ﻋﻠﻰ ﺻﻤﺎﻡ ﺍﻟﺸﺤﻦ ﺣﺘﻰ ﻋﺰﻡ ﺍﻟﺪﻭﺭﺍﻥ ﺍﻟﻤﺤﺪﺩ‪) .‬ﺍﻧﻈﺮ ﺍﻟﺠﺪﻭﻝ‬
‫ﺃﺩﻧﺎﻩ(‬
‫ﻗﻢ ﺑﻨﺰﻉ ﺍﻟﺴﺪﺍﺩﺍﺕ ﺍﻟﻔﺎﺭﻏﺔ ﺛﻢ ﺍﻓﺘﺢ ﺍﻟﺼﻤﺎﻣﺎﺕ ﺍﻟﺜﻼﺛﻴﺔ ﺑﺎﻟﻜﺎﻣﻞ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﻔﺘﺎﺡ ﺭﺑﻂ ﺳﺪﺍﺳﻲ ﺍﻷﺿﻼﻉ ]ﻋﺰﻡ ﺍﻟﺪﻭﺭﺍﻥ ‪ ٦ :‬ﺇﻟﻰ‬
‫‪ ٧‬ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )‪ ٦٠‬ﺇﻟﻰ ‪ ٧٠‬ﻛﺠﻢ ﻕ‪/‬ﺳﻢ([‬
‫ﻗﻢ ﺑﺸﺪ ﺍﻟﺴﺪﺍﺩﺍﺕ ﺍﻟﻔﺎﺭﻏﺔ ﻟﻠﺼﻤﺎﻡ ﺍﻟﺜﻼﺛﻲ ﺣﺘﻰ ﻋﺰﻡ ﺍﻟﺪﻭﺭﺍﻥ ﺍﻟﻤﺤﺪﺩ‪.‬‬
‫ﺍﻟﻘﻄﺮ ﺍﻟﺨﺎﺭﺟﻲ ﻟﻸﻧﺒﻮﺏ‬
‫ﺳﺪﺍﺩﺓ ﻓﺎﺭﻏﺔ‬
‫ﺗﺸﺪﻳﺪ ﻋﺰﻡ ﺍﻟﺪﻭﺭﺍﻥ‬
‫‪ ٦٫٣٥‬ﻣﻢ )‪ ١/٤‬ﺑﻮﺻﺔ(‬
‫‪ ٢٠‬ﺇﻟﻰ ‪ ٢٥‬ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )‪ ٢٠٠‬ﺇﻟﻰ ‪ ٢٥٠‬ﻛﺠﻢ ﻕ‪/‬ﺳﻢ(‬
‫‪ ٩٫٥٢‬ﻣﻢ )‪ ٣/٨‬ﺑﻮﺻﺔ(‬
‫‪ ٢٠‬ﺇﻟﻰ ‪ ٢٥‬ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )‪ ٢٠٠‬ﺇﻟﻰ ‪ ٢٥٠‬ﻛﺠﻢ ﻕ‪/‬ﺳﻢ(‬
‫‪ ١٢٫٧٠‬ﻣﻢ )‪ ١/٢‬ﺑﻮﺻﺔ(‬
‫‪ ٢٨‬ﺇﻟﻰ ‪ ٣٢‬ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )‪ ٢٨٠‬ﺇﻟﻰ ‪ ٣٢٠‬ﻛﺠﻢ ﻕ‪/‬ﺳﻢ(‬
‫‪ ١٥٫٨٨‬ﻣﻢ )‪ ٥/٨‬ﺑﻮﺻﺔ(‬
‫‪ ٣٠‬ﺇﻟﻰ ‪ ٣٥‬ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )‪ ٣٠٠‬ﺇﻟﻰ ‪ ٣٥٠‬ﻛﺠﻢ ﻕ‪/‬ﺳﻢ(‬
‫ﺳﺪﺍﺩﺓ ﻣﻨﻔﺬ ﺍﻟﺸﺤﻦ‬
‫‪ ١٢٫٥‬ﺇﻟﻰ ‪ ١٦‬ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )‪ ١٢٥‬ﺇﻟﻰ ‪ ١٦٠‬ﻛﺠﻢ ﻕ‪/‬ﺳﻢ(‬
‫ﺗﺤﺬﻳﺮ‬
‫ﻋﻨﺪ ﻧﻘﻞ ﺃﻭ ﺗﺮﻛﻴﺐ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء‪ ،‬ﻻ ﺗﻘﻢ ﺑﻤﺰﺝ ﻏﺎﺯﺍﺕ ﺧﻼﻑ ﺳﺎﻟﺐ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻟﻤﺨﺼﺺ ‪ R410A‬ﺩﺍﺧﻞ ﺩﺍﺋﺮﺓ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫ﺇﺫﺍ ﺩﺧﻞ ﺍﻟﻬﻮﺍء ﺍﻟﺠﻮﻱ ﺃﻭ ﺃﻱ ﻏﺎﺯ ﺁﺧﺮ ﺇﻟﻰ ﺩﻭﺭﺓ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺳﻴﺮﺗﻔﻊ ﺍﻟﻀﻐﻂ ﺩﺍﺧﻞ ﺍﻟﺪﻭﺭﺓ ﺇﻟﻰ ﺣﺪ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﻣﻤﺎ ﻳﻨﺘﺞ‬
‫ﻋﻨﻪ ﺣﺪﻭﺙ ﺃﻋﻄﺎﻝ ﺃﻭ ﺣﺪﻭﺙ ﺇﺻﺎﺑﺎﺕ ‪...‬ﺍﻟﺦ‪.‬‬
‫ﺗﻨﺒﻴﻪ‬
‫ﺑﻌﺪ ﺗﻔﺮﻳﻎ ﻫﻮﺍء ﺍﻟﻨﻈﺎﻡ‪ ،‬ﺃﺿﻒ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫ﻻ ﺗﻌﻴﺪ ﺍﺳﺘﺨﺪﺍﻡ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻟﻤﺴﺘﺮﺩ‪.‬‬
‫ﻋﻨﺪ ﺷﺤﻦ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪ ،R410A‬ﺍﺳﺘﺨﺪﻡ ﺩﺍﺋﻤﺎ ﻣﻮﺍﺯﻳﻦ ﺍﻟﻜﺘﺮﻭﻧﻴﺔ ﻟﺸﺤﻦ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ )ﻟﻘﻴﺎﺱ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺣﺴﺐ ﺍﻟﻮﺯﻥ(‪.‬‬
‫ﺇﺿﺎﻓﺔ ﺳﺎﺋﻞ ﺗﺒﺮﻳﺪ ﺃﻛﺜﺮ ﻣﻦ ﺍﻟﻜﻤﻴﺔ ﺍﻟﻤﺤﺪﺩﺓ ﺳﻴﺘﺴﺒﺐ ﻓﻲ ﺣﺪﻭﺙ ﺧﻠﻞ ﻓﻲ ﺍﻟﻌﻤﻞ‪.‬‬
‫ﻋﻨﺪ ﺷﺤﻦ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺧﺬ ﻓﻲ ﺍﻻﻋﺘﺒﺎﺭ ﺍﻟﺘﻐﻴﺮ ﺍﻟﻄﻔﻴﻒ ﻓﻲ ﺗﻜﻮﻳﻦ ﺍﻟﻐﺎﺯ ﻭﻣﺮﺍﺣﻞ ﺍﻟﺴﺎﺋﻞ‪ ،‬ﻭﺍﺷﺤﻦ ﺩﺍﺋﻤﺎ ﻣﻦ ﺟﺎﻧﺐ ﻣﺮﺣﻠﺔ‬
‫ﺍﻟﺴﺎﺋﻞ ﺍﻟﺬﻱ ﻳﻜﻮﻥ ﺗﻜﻮﻳﻨﻪ ﻣﺴﺘﻘﺮ‪ .‬ﺇﺿﺎﻓﺔ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻣﻦ ﺧﻼﻝ ﺃﻧﺒﻮﺏ ﺍﻟﻐﺎﺯ ﺳﻴﺘﺴﺒﺐ ﻓﻲ ﺣﺪﻭﺙ ﺧﻠﻞ ﻓﻲ ﺍﻟﻌﻤﻞ‪.‬‬
‫ﺗﺄﻛﺪ ﻣﻤﺎ ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻷﺳﻄﻮﺍﻧﺔ ﺍﻟﺼﻠﺐ ﺑﻬﺎ ﺳﻴﻔﻮﻥ ﻣﺮﻛﺐ ﺃﻭ ﻻ ﻗﺒﻞ ﺍﻟﺘﻌﺒﺌﺔ‪) .‬ﻳﻮﺟﺪ ﻣﺆﺷﺮ "ﻣﻊ ﺍﻟﺴﻴﻔﻮﻥ ﻟﺘﻌﺒﺌﺔ ﺍﻟﺴﺎﺋﻞ" ﻋﻠﻰ‬
‫ﺍﻷﺳﻄﻮﺍﻧﺔ ﺍﻟﺼﻠﺐ‪(.‬‬
‫ﻃﺮﻳﻘﺔ ﺍﻟﺘﻌﺒﺌﺔ ﻣﻦ ﺍﻷﺳﻄﻮﺍﻧﺔ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺍﻟﺴﻴﻔﻮﻥ‬
‫‪R410A‬‬
‫ﺍﻟﻐﺎﺯ‬
‫ﺿﻊ ﺍﻷﺳﻄﻮﺍﻧﺔ ﻋﻤﻮﺩﻳﺎ ﻭﻗﻢ ﺑﺘﻌﺒﺌﺔ ﺍﻟﺴﺎﺋﻞ‪.‬‬
‫)ﻳﻤﻜﻦ ﺗﻌﺒﺌﺔ ﺍﻟﺴﺎﺋﻞ ﺑﺪﻭﻥ ﺍﻟﻘﻠﺐ ﻣﻦ ﺃﺳﻔﻞ ﻷﻋﻠﻰ ﺑﺎﺳﺘﻌﻤﺎﻝ ﺩﺍﺧﻞ ﺍﻟﺴﻴﻔﻮﻥ‪(.‬‬
‫ﺍﻟﺴﺎﺋﻞ‬
‫ﻃﺮﻳﻘﺔ ﺗﻌﺒﺌﺔ ﻣﻦ ﺍﻷﺳﻄﻮﺍﻧﺎﺕ ﺍﻷﺧﺮﻯ‬
‫‪R410A‬‬
‫ﺍﻟﻐﺎﺯ‬
‫ﻗﻢ ﺑﺎﻟﻘﻠﺐ ﻣﻦ ﺃﺳﻔﻞ ﻷﻋﻠﻰ ﻭﻗﻢ ﺑﺘﻌﺒﺌﺔ ﺍﻟﺴﺎﺋﻞ‪.‬‬
‫)ﺍﺣﺮﺹ ﻋﻠﻰ ﺗﺠﻨﺐ ﻗﻠﺐ ﺍﻷﺳﻄﻮﺍﻧﺔ(‬
‫ﺍﻟﺴﺎﺋﻞ‬
‫ﺗﺄﻛﺪ ﻣﻦ ﺍﺳﺘﻌﻤﺎﻝ ﺍﻷﺩﻭﺍﺕ ﺍﻟﺨﺎﺻﺔ ﺑﺴﺎﺋﻞ ‪ R410A‬ﻟﻤﻘﺎﻭﻣﺔ ﺍﻟﻀﻐﻂ ﻭﻟﺘﺠﻨﺐ ﺧﻠﻂ ﺍﻟﻤﻮﺍﺩ ﺍﻟﻤﻠﻮﺛﺔ‪.‬‬
‫ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﻤﺴﺎﻓﺔ ﺑﻴﻦ ﺍﻟﻮﺣﺪﺗﺎﻥ ﺃﺑﻌﺪ ﺃﻗﺼﻰ ﻃﻮﻝ ﻟﻸﻧﺎﺑﻴﺐ‪ ،‬ﻻ ﻳﻤﻜﻦ ﺿﻤﺎﻥ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﺼﺤﻴﺢ‪.‬‬
‫ﺗﺄﻛﺪ ﻣﻦ ﻏﻠﻖ ﺍﻟﺼﻤﺎﻡ ﺑﻌﺪ ﺷﺤﻦ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ .‬ﻭﺑﺨﻼﻑ ﺫﻟﻚ‪ ،‬ﻗﺪ ﻳﺘﻌﻄﻞ ﺍﻟﻀﺎﻏﻂ ﻋﻦ ﺍﻟﻌﻤﻞ‪.‬‬
‫ﻗﻠﻞ ﺗﺤﺮﻳﺮ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻓﻲ ﺍﻟﻬﻮﺍء ﺇﻟﻰ ﺍﺩﻧﻰ ﺣﺪ‪ .‬ﻣﺤﻈﻮﺭ ﺍﻟﺘﺤﺮﻳﺮ ﺍﻟﺰﺍﺋﺪ ﻋﻦ ﺍﻟﺤﺪ ﺑﻤﻮﺟﺐ ﻗﺎﻧﻮﻥ ﺗﺠﻤﻴﻊ ﺍﻟﻔﺮﻳﻮﻥ ﻭﺍﻟﺘﺪﻣﻴﺮ‪.‬‬
‫‪Ar-٦‬‬
‫‪29/3/2559 8:43:31‬‬
‫‪9381069118_IM_AR.indd 6‬‬
‫ﺍﻟﻘﻄﺮ ﺍﻟﺨﺎﺭﺟﻲ ﻟﻸﻧﺒﻮﺏ‬
‫‪ ٢ ٤‬ﻣﺘﻄﻠﺒﺎﺕ ﺍﻷﻧﺎﺑﻴﺐ‬
‫‪) A‬ﻣﻢ(‬
‫ﺍﻟﻘﻄﺮ ﺍﻟﺨﺎﺭﺟﻲ‬
‫ﻟﻸﻧﺒﻮﺏ‬
‫ﺃﺩﺍﺓ ﺗﻮﺳﻴﻊ ﻟﻠﻨﻮﻉ ‪،R410A‬‬
‫ﻧﻮﻉ ﺫﻱ ﻣﻘﺒﺾ‬
‫ﻧﻮﻉ ﺫﻱ ﻣﻘﺒﺾ‬
‫‪ ٦٫٣٥‬ﻣﻢ )‪ ١/٤‬ﺑﻮﺻﺔ(‬
‫‪ ٠‬ﺇﻟﻰ ‪٠٫٥‬‬
‫‪ ١٫٠‬ﺇﻟﻰ ‪١٫٥‬‬
‫‪ ١٫٥‬ﺇﻟﻰ ‪٢٫٠‬‬
‫‪ ١٥٫٨٨‬ﻣﻢ )‪ ٥/٨‬ﺑﻮﺻﺔ(‬
‫‪ ٠‬ﺇﻟﻰ ‪٠٫٥‬‬
‫‪ ١٫٠‬ﺇﻟﻰ ‪١٫٥‬‬
‫‪ ٢٫٠‬ﺇﻟﻰ ‪٢٫٥‬‬
‫ﺗﻨﺒﻴﻪ‬
‫ﺣﺎﻓﻆ ﻋﻠﻰ ﻃﻮﻝ ﺍﻷﻧﺎﺑﻴﺐ ﺑﻴﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﺍﻟﺤﺪﻭﺩ ﺍﻟﻤﺴﻤﻮﺡ ﺑﻬﺎ‪.‬‬
‫ُﻗﻄﺮ ﺍﻷﻧﺎﺑﻴﺐ >ﺍﻟﺴﺎﺋﻞ‪/‬ﺍﻟﻐﺎﺯ<‬
‫)ﻗﻴﺎﺳﻲ(‬
‫‪(٥ / ٨) ١٥٫٨٨ / (١ / ٤) ٦٫٣٥‬‬
‫]ﻣﻢ )ﺑﻮﺻﺔ([‬
‫ﺃﻗﺼﻰ ﻃﻮﻝ ﻟﻠﺴﻠﻚ‬
‫ﺃﻗﻞ ﻃﻮﻝ ﻟﻠﺴﻠﻚ‬
‫‪ ٣ ٤ ٤‬ﺛﻨﻲ ﺍﻷﻧﺎﺑﻴﺐ‬
‫ﻗﻢ ﺑﺘﺸﻜﻴﻞ ﺍﻷﻧﺎﺑﻴﺐ ﺑﻴﺪﻳﻚ‪ .‬ﻭﺍﺣﺮﺹ ﻋﻠﻰ ﺃﻻ ﺗﻨﻄﺒﻖ ﺟﺪﺭﺍﻧﻬﺎ ﻋﻠﻰ ﺑﻌﻀﻬﺎ ﺍﻟﺒﻌﺾ‪.‬‬
‫ﻻ ﺗﻘﻢ ﺑﺜﻨﻲ ﺍﻷﻧﺎﺑﻴﺐ ﺑﺰﺍﻭﻳﺔ ﺗﺰﻳﺪ ﻋﻦ ‪ ٩٠‬ﺩﺭﺟﺔ‪.‬‬
‫ﻓﻌﻨﺪﻣﺎ ﺗﺘﻌﺮﺽ ﺍﻷﻧﺎﺑﻴﺐ ﻟﻠﺜﻨﻲ ﺍﻟﻤﺘﻜﺮﺭ ﺃﻭ ﺍﻟﺘﻤﺪﻳﺪ ﻓﺈﻥ ﺍﻟﻤﺎﺩﺓ ﺳﻮﻑ ﺗﺘﺼﻠﺐ ﻭﺗﺠﻌﻞ ﺛﻨﻴﻬﺎ ﺃﻭ ﺗﻤﺪﻳﺪﻫﺎ ﺃﻣﺮﺍ ﺻﻌﺒﺎ‪.‬‬
‫ﺗﺠﻨﺐ ﺛﻨﻲ ﺍﻷﻧﺎﺑﻴﺐ ﺃﻭ ﺗﻤﺪﻳﺪﻫﺎ ﺃﻛﺜﺮ ﻣﻦ ﺛﻼﺙ ﻣﺮﺍﺕ‪.‬‬
‫‪٢٠‬‬
‫]ﻡ[‬
‫ﺃﺩﺍﺓ ﺗﻮﺳﻴﻊ ﺗﻘﻠﻴﺪﻳﺔ )‪(R22‬‬
‫ﻧﻮﻉ ﺻﺎﻣﻮﻟﺔ ﻣﺠﻨﺤﺔ‬
‫‪٥‬‬
‫]ﻡ[‬
‫ﺃﻗﺼﻰ ﻓﺮﻕ ﺍﺭﺗﻔﺎﻉ‬
‫>ﻣﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺇﻟﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ<‬
‫ﺍﻷﻧﺒﻮﺏ‬
‫• ﻋﻨﺪ ﺛﻨﻲ ﺃﻧﺒﻮﺏ‪ ،‬ﻻ ﺗﻘﻢ ﺑﺜﻨﻴﻪ ﻛﻤﺎ ﻫﻮ‪ .‬ﺳﻴﺘﻌﺮﺽ ﺍﻷﻧﺒﻮﺏ‬
‫ﻟﻠﻜﺴﺮ‪ .‬ﻓﻲ ﻫﺬﻩ ﺍﻟﺤﺎﻟﺔ‪ ،‬ﻗﻢ ﺑﻘﺺ ﺃﻧﺒﻮﺏ ﺍﻟﻌﺰﻝ ﺑﺎﺳﺘﺨﺪﺍﻡ‬
‫ﻗﺎﻃﻊ ﺣﺎﺩ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻋﻠﻰ ﺍﻟﺠﺎﻧﺐ ﺍﻷﻳﻤﻦ‪ ،‬ﺛﻢ ﺛﻨﻴﻪ ﺑﻌﺪ‬
‫ﻇﻬﻮﺭ ﺍﻷﻧﺒﻮﺏ‪ .‬ﺑﻌﺪ ﺛﻨﻲ ﺍﻷﻧﺒﻮﺏ ﻛﻤﺎ ﺗﺮﻏﺐ‪ ،‬ﺗﺄﻛﺪ ﻣﻦ‬
‫ﻭﺿﻊ ﺃﻧﺒﻮﺏ ﺍﻟﻌﺰﻝ ﺍﻟﺤﺮﺍﺭﻱ ﻣﺮﺓ ﺃﺧﺮﻯ ﻋﻠﻰ ﺍﻷﻧﺒﻮﺏ‬
‫ﻭﺗﺄﻣﻴﻨﻪ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺷﺮﻳﻂ‪.‬‬
‫‪٨‬‬
‫]ﻡ[‬
‫• ﺍﺳﺘﺨﺪﻡ ﺃﻧﺒﻮﺏ ﻋﺎﺯﻝ ﻭﻣﻘﺎﻭﻡ ﻟﻠﻤﺎء ﻭﺍﻟﺤﺮﺍﺭﺓ‪.‬‬
‫ﻋﺎﺯﻝ‬
‫ﺍﻷﻧﺒﻮﺏ‬
‫ﻗﺎﻃﻊ‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﻋﺎﺯﻝ ﺍﻟﺤﺮﺍﺭﺓ ﺣﻮﻝ ﺃﻧﺒﻮﺑﻲ ﺍﻟﻐﺎﺯ‪ .‬ﻭﺍﻟﺴﺎﺋﻞ‪ ،‬ﻗﺪ ﻳﺴﺒﺐ ﻋﺪﻡ ﺍﻟﻘﻴﺎﻡ ﺑﺬﻟﻚ ﺗﺴﺮﺏ ﺍﻟﻤﻴﺎﻩ‪.‬‬
‫ﻳﺴﺘﺨﺪﻡ ﻋﺎﺯﻝ ﺍﻟﺤﺮﺍﺭﺓ ﻣﻊ ﻣﻘﺎﻭﻣﺔ ﻟﻠﺤﺮﺍﺭﺓ ﺗﺘﺠﺎﻭﺯ ‪ ١٢٠‬ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ‪) .‬ﻃﺮﺍﺯ ﺍﻟﺪﻭﺭﺓ ﺍﻟﻌﻜﺴﻴﺔ ﻓﻘﻂ(‬
‫ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺃﻧﻪ ﺇﺫﺍ ﻛﺎﻥ ﻣﺴﺘﻮﻯ ﺍﻟﺮﻃﻮﺑﺔ ﺍﻟﻤﺘﻮﻗﻌﺔ ﺗﺨﻄﻰ ‪ ٪ ٧٠‬ﻓﻲ ﻣﻮﻗﻊ ﺗﺮﻛﻴﺐ ﺃﻧﺒﻮﺏ ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫ﺇﺫﺍ ﻛﺎﻥ ﻣﺴﺘﻮﻯ ﺍﻟﺮﻃﻮﺑﺔ ﺍﻟﻤﺘﻮﻗﻌﺔ ‪ ٪ ٨٠-٧٠‬ﻓﺄﻋﻤﺪ ﺇﻟﻰ ﺍﺳﺘﻌﻤﺎﻝ ﻋﺎﺯﻝ ﺣﺮﺍﺭﻱ ﺑﺴﻤﺎﻛﺔ ‪ ١٥‬ﻣﻢ ﺃﻭ ﺃﺳﻤﻚ‪ ،‬ﻭﺇﺫﺍ ﺗﺨﻄﺖ‬
‫ﺍﻟﺮﻃﻮﺑﺔ ﺍﻟﻤﺘﻮﻗﻌﺔ ‪ ،٪ ٨٠‬ﻓﺄﻋﻤﺪ ﺇﻟﻰ ﺍﺳﺘﻌﻤﺎﻝ ﻋﺎﺯﻝ ﺣﺮﺍﺭﻱ ﺑﺴﻤﺎﻛﺔ ‪ ٢٠‬ﻣﻢ ﺃﻭ ﺃﺳﻤﻚ‪.‬‬
‫ﺇﺫﺍ ﻟﻢ ﺗﻜﻦ ﺳﻤﺎﻛﺔ ﺍﻟﻌﺎﺯﻝ ﺍﻟﺤﺮﺍﺭﻱ ﺍﻟﻤﺴﺘﻌﻤﻞ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﻤﻮﺻﻮﻑ‪ ،‬ﻓﻘﻂ ﻳﺤﺪﺙ ﺗﻜﺜﻒ ﻋﻠﻰ ﺳﻄﺢ ﺍﻟﻌﺎﺯﻝ‪.‬‬
‫ﺇﺿﺎﻓﺔ ﺇﻟﻰ ﺫﻟﻚ‪ ،‬ﻗﻢ ﺑﺎﺳﺘﻌﻤﺎﻝ ﺍﻟﻌﺰﻝ ﺍﻟﺤﺮﺍﺭﻱ ﻣﻊ ﻣﻮﺻﻞ ﺣﺮﺍﺭﻱ ‪ ٠٫٠٤٥‬ﻭﺍﺕ )ﻡ‪/‬ﻙ( ﺃﻭ ﺃﻗﻞ )ﻋﻨﺪ ‪ ٢٠‬ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ(‪.‬‬
‫ﺧﻂ ﺍﻟﻘﻄﻊ‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻟﻤﻨﻊ ﺍﻧﻜﺴﺎﺭ ﺍﻷﻧﺒﻮﺏ‪ ،‬ﺗﺠﻨﺐ ﺍﻟﺜﻨﻴﺎﺕ ﺍﻟﺤﺎﺩﺓ‪.‬‬
‫ﺇﺛﻦ ﺍﻷﻧﺒﻮﺏ ﺑﻨﺼﻒ ﻗﻄﺮ ﺍﻧﺤﻨﺎء ﻣﻘﺪﺍﺭﻩ ‪ ١٥٠‬ﻣﻢ ﺃﻭ ﺃﻛﺒﺮ‪.‬‬
‫ﺇﺫﺍ ﺗﻜﺮﺭ ﺛﻨﻲ ﺍﻷﻧﺒﻮﺏ ﻣﻦ ﻧﻔﺲ ﺍﻟﻤﻜﺎﻥ ﻓﺈﻧﻪ ﻳﻨﻜﺴﺮ‪.‬‬
‫‪ ٤ ٤ ٤‬ﺃﻧﺒﻮﺏ ﺍﻟﺘﻮﺻﻴﻞ‬
‫‪ ٣ ٤‬ﺍﻟﻠﺤﺎﻡ ﺑﺎﻟﻨﺤﺎﺱ ﺍﻷﺻﻔﺮ‬
‫ﺗﻨﺒﻴﻪ‬
‫ﺗﻨﺒﻴﻪ‬
‫ﺇﺫﺍ ﺩﺧﻞ ﻫﻮﺍء ﺃﻭ ﻧﻮﻉ ﺁﺧﺮ ﻣﻦ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻓﻲ ﺩﻭﺭﺓ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺳﻴﺼﺒﺢ ﺍﻟﻀﻐﻂ ﺍﻟﺪﺍﺧﻠﻲ ﻓﻲ ﺩﻭﺭﺓ ﺍﻟﺘﺒﺮﻳﺪ ﻣﺮﺗﻔﻌﺎ ﺑﺸﻜﻞ ﻏﻴﺮ‬
‫ﻋﺎﺩﻱ ﻭﻳﻤﻨﻊ ﺍﻟﻮﺣﺪﺓ ﻣﻦ ﺃﺩﺍء ﻋﻤﻠﻬﺎ ﺑﺸﻜﻞ ﻛﺎﻣﻞ‪.‬‬
‫ﺻﻤﺎﻡ ﺗﻨﻈﻴﻢ ﺍﻟﻀﻐﻂ‬
‫ﺍﻟﺴﺪﺍﺩﺓ‬
‫ﻃﺒﻖ ﻏﺎﺯ ﺍﻟﻨﻴﺘﺮﻭﺟﻴﻦ ﺃﺛﻨﺎء ﻟﺤﺎﻡ ﺍﻷﻧﺎﺑﻴﺐ‪ .‬ﻓﻲ ﺣﺎﻝ ﻟﺤﺎﻡ ﺃﻧﺒﻮﺏ ﺑﺪﻭﻥ ﺗﻄﺒﻴﻖ ﻏﺎﺯ‬
‫ﺍﻟﻨﻴﺘﺮﻭﺟﻴﻦ‪ ،‬ﺳﻴﻨﺸﺄ ﻏﺸﺎء ﺃﻛﺴﺪﺓ‪.‬‬
‫ﻫﺬﺍ ﻳﻤﻜﻦ ﺃﻥ ﻳﻘﻠﻞ ﺍﻷﺩﺍء ﺃﻭ ﻳﺘﺴﺒﺐ ﻓﻲ ﺗﻠﻒ ﺃﺟﺰﺍء ﺍﻟﻮﺣﺪﺓ )ﻣﺜﻞ ﺍﻟﻀﺎﻏﻂ‬
‫ﻭﺍﻟﺼﻤﺎﻣﺎﺕ(‪.‬‬
‫ﺿﻐﻂ ﻏﺎﺯ ﺍﻟﻨﻴﺘﺮﻭﺟﻴﻦ ‪ ٠٫٠٢‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ‬
‫ﻛﺎﻑ ﻋﻠﻰ ﻇﻬﺮ ﺍﻟﻴﺪ(‬
‫)= ﺍﻟﻀﻐﻂ ﺍﻟﺬﻱ ﻳﺘﻢ ﺍﻟﺸﻌﻮﺭ ﺑﻪ ﺑﺸﻜﻞ ٍ‬
‫ﻏﺎﺯ ﺍﻟﻨﺘﺮﻭﺟﻴﻦ‬
‫ﻣﻨﻄﻘﺔ ﺍﻟﻠﺤﺎﻡ‬
‫ﻟﻠﺤﺎﻡ ﺍﻟﻤﻮﺍﺩ‪ ،‬ﺍﺳﺘﺨﺪﻡ ﻧﺤﺎﺱ ﻓﺴﻔﻮﺭﻱ ﻻ ﻳﺘﻄﻠﺐ ﺻﻬﻮﺭ‪ .‬ﻻ ﺗﺴﺘﺨﺪﻡ ﺻﻬﻮﺭ ﻟﻠﺤﺎﻡ ﺍﻷﻧﺎﺑﻴﺐ‪ .‬ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﺼﻬﻮﺭ ﻣﻦ ﻧﻮﻉ ﺍﻟﻜﻠﻮﺭ‪،‬‬
‫ﺳﻴﺘﺴﺒﺐ ﻓﻲ ﺗﺂﻛﻞ ﺍﻷﻧﺎﺑﻴﺐ‪.‬‬
‫ﻋﻼﻭﺓ ﻋﻠﻰ ﺫﻟﻚ‪ ،‬ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﺼﻬﻮﺭ ﻳﺤﺘﻮﻱ ﻋﻠﻰ ﺍﻟﻔﻠﻮﺭﻳﺪ‪ ،‬ﺳﻴﺆﺛﺮ ﻋﻜﺴﻴﺎً ﻋﻠﻰ ﻧﻈﺎﻡ ﺃﻧﺎﺑﻴﺐ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﻣﺜﻼ ﻋﻦ ﻃﺮﻳﻖ ﺗﻘﻠﻴﻞ‬
‫ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﻔﻠﻮﺭﻳﺪ ﻣﻀﻤ ًﻨﺎ‪ ،‬ﺗﻨﺨﻔﺾ ﺟﻮﺩﺓ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻭﺗﺆﺛﺮ ﻋﻠﻰ ﻧﻈﺎﻡ ﺃﻧﺎﺑﻴﺐ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫ﺗﺤﺮﻯ ﻣﻦ ﻭﺿﻊ ﺍﻷﻧﺒﻮﺏ ﻓﻲ ﻣﻘﺎﺑﻞ ﻓﺘﺤﺔ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﻤﺮﻛﺰ ﻏﻴﺮ ﺻﺤﻴﺢ ﻓﻠﻦ ﻳﻜﻮﻥ ﻣﻦ ﺍﻟﻤﻤﻜﻦ ﺇﺣﻜﺎﻡ ﺻﺎﻣﻮﻟﺔ‬
‫ﺍﻟﺘﻮﺳﻴﻊ ﺑﺴﻼﺳﺔ‪ .‬ﺇﺫﺍ ﺗﻢ ﻟﻒ ﺍﻟﺼﺎﻣﻮﻟﺔ ﺍﻟﺘﻮﺳﻴﻌﻴﺔ ﺑﻘﻮﺓ ﻓﺈﻥ ﺃﺳﻨﺎﻧﻬﺎ ﺗﺘﻠﻒ‪.‬‬
‫ﻻ ﺗﻨﺰﻉ ﺍﻟﺼﺎﻣﻮﻟﺔ ﺍﻟﺘﻮﺳﻴﻌﻴﺔ ﻋﻦ ﺃﻧﺒﻮﺏ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺇﻻ ﻗﺒﻞ ﺗﻮﺻﻴﻞ ﺃﻧﺒﻮﺏ ﺍﻟﺘﻮﺻﻴﻞ ﻣﺒﺎﺷﺮﺓ‪.‬‬
‫ﺑﻌﺪ ﺗﺮﻛﻴﺐ ﺍﻷﻧﺎﺑﻴﺐ‪ ،‬ﺗﺄﻛﺪ ﻣﻦ ﺃﻥ ﺃﻧﺎﺑﻴﺐ ﺍﻟﺘﻮﺻﻴﻞ ﻻ ﺗﻠﻤﺲ ﺍﻟﻀﺎﻏﻂ ﺃﻭ ﺍﻟﻠﻮﺣﺔ ﺍﻟﺨﺎﺭﺟﻴﺔ‪ .‬ﺇﺫﺍ ﻟﻤﺴﺖ ﺍﻷﻧﺎﺑﻴﺐ ﺍﻟﻀﺎﻏﻂ ﺃﻭ‬
‫ﺍﻟﻠﻮﺣﺔ ﺍﻟﺨﺎﺭﺟﻴﺔ‪ ،‬ﺳﺘﻬﺘﺰ ﻭﺗﺼﺪﺭ ﺿﻮﺿﺎء‪.‬‬
‫)‪ (١‬ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺣﻠﻘﺔ ﺣﺎﺋﻂ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ )ﺍﻟﻤﺰﻭﺩﺓ ﻣﻊ ﻣﺠﻤﻮﻋﺔ ﺍﻟﺘﺮﻛﻴﺐ ﺍﻻﺧﺘﻴﺎﺭﻳﺔ ﺃﻭ ﻣﺘﻮﻓﺮﺓ ﻓﻲ ﺍﻟﻤﻮﻗﻊ( ﺑﺄﻧﺒﻮﺏ ﻓﺘﺤﺔ‬
‫ﺍﻟﺤﺎﺋﻂ‪.‬‬
‫)‪ (٢‬ﻗﻢ ﺑﺘﻮﺻﻴﻞ ﺃﻧﺎﺑﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻭﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‪.‬‬
‫)‪ (٣‬ﺑﻌﺪ ﻣﻄﺎﺑﻘﺔ ﻣﺮﻛﺰ ﺳﻄﺢ ﺍﻟﺘﻮﺳﻴﻊ ﻭﺇﺣﻜﺎﻡ ﺭﺑﻂ ﺍﻟﺼﺎﻣﻮﻟﺔ‪ ،‬ﻗﻢ ﺑﺈﺣﻜﺎﻡ ﺍﻟﺼﺎﻣﻮﻟﺔ ً‬
‫ﻭﻓﻘﺎ ﻟﻌﺰﻡ ﺍﻟﺮﺑﻂ ﺍﻟﻤﺤﺪﺩ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﻔﺘﺎﺡ‬
‫ﺭﺑﻂ‪.‬‬
‫ﺃﻧﺒﻮﺏ ﺍﻟﺘﻮﺻﻴﻞ‬
‫‪ ٤ ٤‬ﺗﻮﺻﻴﻞ ﺍﻷﻧﺎﺑﻴﺐ‬
‫ﺻﺎﻣﻮﻟﺔ ﺍﻟﺘﻮﺳﻴﻊ‬
‫‪ ١ ٤ ٤‬ﺣﻤﺎﻳﺔ ﺍﻷﻧﺎﺑﻴﺐ‬
‫ﻣﻔﺘﺎﺡ ﻋﺰﻡ ﺍﻟﺪﻭﺭﺍﻥ‬
‫‪°٩٠‬‬
‫ﺃﺣﻤﻲ ﺍﻷﻧﺎﺑﻴﺐ ﻟﻤﻨﻊ ﺩﺧﻮﻝ ﺍﻟﺮﻃﻮﺑﺔ ﻭﺍﻷﺗﺮﺑﺔ‪.‬‬
‫ﻭﻋﻠﻰ ﻭﺟﻪ ﺍﻟﺨﺼﻮﺹ‪ ،‬ﺍﻧﺘﺒﻪ ﻋﻨﺪ ﺗﻤﺮﻳﺮ ﺍﻷﻧﺎﺑﻴﺐ ﺧﻼﻝ ﻓﺘﺤﺔ ﺃﻭ ﺗﻮﺻﻴﻞ ﻧﻬﺎﻳﺔ ﺃﻧﺒﻮﺏ ﺑﺎﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪.‬‬
‫ﺍﻟﻤﻜﺎﻥ‬
‫ﺧﺎﺭﺝ ﺍﻟﻐﺮﻓﺔ‬
‫ﻓﺘﺮﺓ ﺍﻟﻌﻤﻞ‬
‫ﻃﺮﻳﻘﺔ ﺍﻟﺤﻤﺎﻳﺔ‬
‫‪ ١‬ﺷﻬﺮ ﺃﻭ ﺃﻛﺜﺮ‬
‫ﺷﺪ ﺍﻷﻧﺎﺑﻴﺐ‬
‫ﺃﻗﻞ ﻣﻦ ﺷﻬﺮ‬
‫ﺷﺪ ﺃﻭ ﺗﻐﻄﻴﺔ ﺍﻷﻧﺎﺑﻴﺐ ﺑﺸﺮﻳﻂ‬
‫‪-‬‬
‫ﺷﺪ ﺃﻭ ﺗﻐﻄﻴﺔ ﺍﻷﻧﺎﺑﻴﺐ ﺑﺸﺮﻳﻂ‬
‫ﺩﺍﺧﻞ ﺍﻟﻐﺮﻓﺔ‬
‫‪ ٢ ٤ ٤‬ﺍﻟﺘﻮﺳﻌﺔ‬
‫)‪ (١‬ﻗﻢ ﺑﻘﺺ ﺃﻧﺒﻮﺏ ﺍﻟﺘﻮﺻﻴﻞ ﺣﺴﺐ ﺍﻟﻄﻮﻝ ﺍﻟﻼﺯﻡ ﺑﻮﺍﺳﻄﺔ ﻣﻘﺺ ﺃﻧﺎﺑﻴﺐ‪.‬‬
‫)‪ (٢‬ﻗﻢ ﺑﺎﻹﻣﺴﺎﻙ ﺑﺎﻷﻧﺒﻮﺏ ﻭﺗﻮﺟﻴﻬﻪ ﺇﻟﻰ ﺃﺳﻔﻞ ﺑﺤﻴﺚ ﻻ ﺗﺪﺧﻞ ﺑﻘﺎﻳﺎ ﻋﻤﻠﻴﺔ ﺍﻟﻘﺺ ﻓﻲ ﺍﻷﻧﺒﻮﺏ ﻭﻗﻢ ﺑﺈﺯﺍﻟﺔ ﺍﻟﺰﻭﺍﺋﺪ‪.‬‬
‫)‪ (٣‬ﺍﺩﺧﻞ ﺍﻟﺼﺎﻣﻮﻟﺔ ﺍﻟﺘﻮﺳﻌﻴﺔ )ﺍﺳﺘﺨﺪﻡ ﺩﺍﺋﻤﺎ ﺍﻟﺼﺎﻣﻮﻟﺔ ﺍﻟﺘﻮﺳﻴﻌﻴﺔ ﺍﻟﻤﺮﻓﻘﺔ ﻣﻊ ﺍﻟﻮﺣﺪﺗﻴﻦ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺍﻟﺨﺎﺭﺟﻴﺔ ﻋﻠﻰ ﺍﻟﺘﻮﺍﻟﻲ( ﻓﻲ‬
‫ﺍﻷﻧﺒﻮﺏ ﻭﻗﻢ ﺑﺎﻟﺘﻮﺳﻴﻊ ﺑﺎﺳﺘﻌﻤﺎﻝ ﺃﺩﺍﺓ ﺗﻮﺳﻴﻊ‪.‬‬
‫ﻗﻢ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺃﺩﺍﺓ ﺗﻮﺳﻴﻊ ‪ R410A‬ﺍﻟﺨﺎﺻﺔ ﺃﻭ ﺃﺩﺍﺓ ﺍﻟﺘﻮﺳﻴﻊ ﺍﻟﺘﻘﻠﻴﺪﻳﺔ )ﺍﻟﺨﺎﺻﺔ ﺏ ‪.(R22‬‬
‫ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ ﺃﺩﺍﺓ ﺗﻮﺳﻴﻊ ﺗﻘﻠﻴﺪﻳﺔ‪ ،‬ﻗﻢ ﺩﺍﺋﻤًﺎ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﻘﻴﺎﺱ ﻟﻀﺒﻂ ﺍﻟﻤﺴﺎﻓﺔ ﻭﺗﺄﻣﻴﻦ ﺍﻟﺒﻌﺪ ‪ A‬ﺍﻟﻤﻮﺿﺢ ﻓﻲ ﺍﻟﺠﺪﻭﻝ ﺍﻟﺘﺎﻟﻲ‪.‬‬
‫ﺗﺤﻘﻖ ﻣﻤﺎ ﺇﺫﺍ ﻛﺎﻥ ]‪ [L‬ﻣﻮﺳﻌﺎ ﺑﺸﻜﻞ‬
‫ﻣﻨﺘﻈﻢ ﻭﺧﺎﻟﻴﺎ ﻣﻦ ﺍﻟﺘﺸﻘﻘﺎﺕ ﻭﺍﻟﺨﺪﻭﺵ‪.‬‬
‫ﺍﻟﻠﻘﻤﺔ‬
‫‪L‬‬
‫‪A‬‬
‫ﻟﻤﻨﻊ ﺗﺴﺮﺏ ﺍﻟﻐﺎﺯ‪ ،‬ﻗﻢ ﺑﺘﻐﻄﻴﺔ ﺳﻄﺢ ﺍﻟﺘﻮﺳﻴﻊ ﺑﻄﺒﻘﺔ ﻣﻦ‬
‫ﺯﻳﺖ ﺃﻟﻜﻴﻠﻮﺑﻨﺰﻳﻦ )‪ .(HAB‬ﻻ ﺗﺴﺘﺨﺪﻡ ﺯﻳﺖ ﻣﻌﺪﻧﻲ‪.‬‬
‫ﻋﺰﻡ ﺷﺪ ﺻﺎﻣﻮﻟﺔ ﺍﻟﺘﻮﺳﻴﻊ‬
‫ﺻﺎﻣﻮﻟﺔ ﺍﻟﺘﻮﺳﻴﻊ‬
‫ﺗﺸﺪﻳﺪ ﻋﺰﻡ ﺍﻟﺪﻭﺭﺍﻥ‬
‫‪ ٦٫٣٥‬ﻣﻢ )‪ ١/٤‬ﺑﻮﺻﺔ( ﺍﻟﻘﻄﺮ‪.‬‬
‫‪ ١٦‬ﺇﻟﻰ ‪ ١٨‬ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )‪ ١٦٠‬ﺇﻟﻰ ‪ ١٨٠‬ﻛﺠﻢ ﻕ‪/‬ﺳﻢ(‬
‫‪ ٩٫٥٢‬ﻣﻢ )‪ ٣/٨‬ﺑﻮﺻﺔ( ﺍﻟﻘﻄﺮ‪.‬‬
‫‪ ٣٢‬ﺇﻟﻰ ‪ ٤٢‬ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )‪ ٣٢٠‬ﺇﻟﻰ ‪ ٤٢٠‬ﻛﺠﻢ ﻕ‪/‬ﺳﻢ(‬
‫‪ ١٢٫٧٠‬ﻣﻢ )‪ ١/٢‬ﺑﻮﺻﺔ( ﺍﻟﻘﻄﺮ‪.‬‬
‫‪ ٤٩‬ﺇﻟﻰ ‪ ٦١‬ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )‪ ٤٩٠‬ﺇﻟﻰ ‪ ٦١٠‬ﻛﺠﻢ ﻕ‪/‬ﺳﻢ(‬
‫‪ ١٥٫٨٨‬ﻣﻢ )‪ ٥/٨‬ﺑﻮﺻﺔ( ﺍﻟﻘﻄﺮ‪.‬‬
‫‪ ٦٣‬ﺇﻟﻰ ‪ ٧٥‬ﻧﻴﻮﺗﻦ‪/‬ﻣﺘﺮ )‪ ٦٣٠‬ﺇﻟﻰ ‪ ٧٥٠‬ﻛﺠﻢ ﻕ‪/‬ﺳﻢ(‬
‫ﻻ ﺗﻘﻢ ﺑﺈﺯﺍﻟﺔ ﺍﻟﺤﻠﻘﺔ ﻣﻦ ﺃﻧﺒﻮﺏ ﺍﻟﺘﻮﺻﻴﻞ ﻗﺒﻞ ﺗﻮﺻﻴﻞ ﺍﻷﻧﺒﻮﺏ‪.‬‬
‫ﺍﻷﻧﺒﻮﺏ‬
‫‪Ar-٥‬‬
‫‪29/3/2559 8:43:31‬‬
‫‪9381069118_IM_AR.indd 5‬‬
‫‪ ٤ ٣‬ﺗﺮﻛﻴﺐ ﺍﻟﺘﺼﺮﻳﻒ‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻗﻢ ﺑﺘﻨﻔﻴﺬ ﺗﺮﻛﻴﺒﺎﺕ ﺍﻟﺘﺼﺮﻳﻒ ﻭﻓﻘﺎ ﻟﻬﺬﺍ ﺍﻟﺪﻟﻴﻞ‪ ،‬ﻭﺗﺄﻛﺪ ﻣﻦ ﺃﻥ ﻣﺎء ﺍﻟﺘﺼﺮﻳﻒ ﻳﺘﻢ ﺗﺼﺮﻳﻔﻪ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﺼﺤﻴﺢ‪ .‬ﺇﺫﺍ ﻟﻢ ﻳﺘﻢ ﺗﻨﻔﻴﺬ‬
‫ﺗﺮﻛﻴﺒﺎﺕ ﺍﻟﺘﺼﺮﻳﻒ ﺑﺸﻜﻞ ﺻﺤﻴﺢ‪ ،‬ﻗﺪ ﺗﺘﻘﺎﻃﺮ ﺍﻟﻤﻴﺎﻩ ﻣﻦ ﺍﻟﻮﺣﺪﺓ‪ ،‬ﻭﺗﺘﺴﺒﺐ ﻓﻲ ﺑﻠﻞ ﺍﻷﺛﺎﺙ‪.‬‬
‫)ﺍﻟﻮﺣﺪﺓ‪ :‬ﻣﻢ(‬
‫ﺍﻟﺠﺎﻧﺐ ﺍﻟﺴﻔﻠﻲ‬
‫ﺗﺪﻓﻖ ﺍﻟﻬﻮﺍء‬
‫‪٥٠‬‬
‫‪٥٠‬‬
‫‪١٢‬‬
‫‪ ٥٠‬ﻣﻢ ﺃﻭ ﺃﻛﺜﺮ‬
‫•‬
‫•‬
‫‪٣٤٣‬‬
‫•‬
‫•‬
‫•‬
‫‪١٢١‬‬
‫‪١٠٦‬‬
‫‪٦٠٣‬‬
‫•‬
‫ﻳﻨﺒﻐﻲ ﺃﻥ ﺗﺪﻋﻢ ﺍﻟﻘﺎﻋﺪﺓ ﺃﺭﺟﻞ ﺍﻟﻮﺣﺪﺓ ﻭﺃﻥ ﺗﻜﻮﻥ ﺑﻮﺳﻊ ‪ ٥٠‬ﻣﻠﻢ ﺃﻭ ﺃﻛﺜﺮ‪.‬‬
‫ﺑﻨﺎء ﻋﻠﻰ ﻇﺮﻭﻑ ﺍﻟﺘﺮﻛﻴﺐ‪ ،‬ﻗﺪ ﻳﻤﺘﺪ ﺍﻫﺘﺰﺍﺯ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺧﻼﻝ ﺍﻟﺘﺸﻐﻴﻞ‪ ،‬ﻣﻤﺎ ﻗﺪ ﻳﺘﺴﺒﺐ ﻓﻲ ﺿﻮﺿﺎء ﺃﻭ ﺍﻫﺘﺰﺍﺯ‪.‬‬
‫ﻟﺬﻟﻚ‪ ،‬ﻗﻢ ﺑﻮﺿﻊ ﻣﻮﺍﺩ ﺗﺨﻤﻴﺪ )ﻣﺜﻞ ﻭﺳﺎﺩﺍﺕ ﺍﻟﺘﺨﻤﻴﺪ( ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺃﺛﻨﺎء ﺍﻟﺘﺮﻛﻴﺐ‪.‬‬
‫ﺭﻛﺐ ﺍﻟﻘﺎﻋﺪﺓ‪ ،‬ﻭﺗﺄﻛﺪ ﻣﻦ ﻭﺟﻮﺩ ﻣﺴﺎﺣﺔ ﻛﺎﻓﻴﺔ ﻟﺘﺮﻛﻴﺐ ﺃﻧﺎﺑﻴﺐ ﺍﻟﺘﻮﺻﻴﻞ‪.‬‬
‫ﻗﻢ ﺑﺘﺄﻣﻴﻦ ﺍﻟﻮﺣﺪﺓ ﻋﻠﻰ ﻛﺘﻠﺔ ﺻﻠﺒﺔ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﺴﺎﻣﻴﺮ ﺍﻟﻘﺎﻋﺪﺓ‪.‬‬
‫)ﺍﺳﺘﺨﺪﻡ ﺍﻷﺭﺑﻊ ﻣﺠﻤﻮﻋﺎﺕ ﺍﻟﻤﺘﺎﺣﺔ ﺗﺠﺎﺭﻳﺎ ﻣﻦ ﺍﻟﻤﺴﺎﻣﻴﺮ ‪ M10‬ﻭﺍﻟﺼﻮﺍﻣﻴﻞ‪ ،‬ﻭﺍﻟﻮﺭﺩ(‬
‫ﻳﻨﺒﻐﻲ ﺃﻥ ﺗﻨﺜﻨﻲ ﺍﻟﻤﺴﺎﻣﻴﺮ ﺑﻤﻘﺪﺍﺭ ‪ ٢٠‬ﻣﻠﻢ‪.‬‬
‫)ﺍﻧﻈﺮ ﺍﻟﺸﻜﻞ ﺃﺩﻧﺎﻩ(‬
‫ﻓﻲ ﺣﺎﻝ ﺿﺮﻭﺭﺓ ﻣﻨﻊ ﺍﻻﻧﻘﻼﺏ‪ ،‬ﻗﻢ ﺑﺸﺮﺍء ﺍﻟﺒﻨﻮﺩ ﺍﻟﻀﺮﻭﺭﻳﺔ ﺍﻟﻤﺘﺎﺣﺔ ﺗﺠﺎﺭﻳﺎ‪.‬‬
‫ﻣﺴﻤﺎﺭ ﺍﻟﺘﺜﺒﻴﺖ‬
‫ﻣﻮﻗﻊ ﺗﺮﻛﻴﺐ‬
‫ﺃﻧﺒﻮﺏ ﺍﻟﺘﺼﺮﻳﻒ‬
‫ﺑﻤﺎ ﺃﻥ ﻣﺎء ﺍﻟﺼﺮﻑ ﻳﺘﺪﻓﻖ ﻣﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺃﺛﻨﺎء ﻋﻤﻠﻴﺔ ﺍﻟﺘﺴﺨﻴﻦ ﻓﻘﻢ ﺑﺘﺮﻛﻴﺐ ﺃﻧﺒﻮﺏ ﺗﺼﺮﻳﻒ ﻳﺒﺎﻉ ﻣﻨﻔﺼﻼ ﻭﻗﻢ ﺑﺘﻮﺻﻴﻠﻪ‬
‫ﺑﺨﺮﻃﻮﻡ ﺗﺠﺎﺭﻱ ﺑﻘﻄﺮ ‪ ١٦‬ﻣﻢ‪.‬‬
‫)ﻃﺮﺍﺯ ﺍﻟﺪﻭﺭﺓ ﺍﻟﻌﻜﺴﻴﺔ ﻓﻘﻂ(‬
‫ﻋﻨﺪ ﺗﺮﻛﻴﺐ ﺃﻧﺒﻮﺏ ﺍﻟﺘﺼﺮﻳﻒ‪ ،‬ﻗﻢ ﺑﺈﻏﻼﻕ ﻛﻞ ﺍﻟﻔﺘﺤﺎﺕ ﺑﺎﺳﺘﺜﻨﺎء ﻓﺘﺤﺔ ﺗﺮﻛﻴﺐ ﺃﻧﺒﻮﺏ ﺍﻟﺘﺼﺮﻳﻒ ﻓﻲ ﻗﺎﻉ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺑﺎﻟﻤﻌﺠﻮﻥ‬
‫ﺑﺤﻴﺚ ﻻ ﻳﺘﻢ ﺗﺴﺮﻳﺐ ﺍﻟﻤﺎء‪.‬‬
‫‪ .٤‬ﺗﺮﻛﻴﺐ ﺍﻷﻧﺎﺑﻴﺐ‬
‫)ﻃﺮﺍﺯ ﺍﻟﺪﻭﺭﺓ ﺍﻟﻌﻜﺴﻴﺔ ﻓﻘﻂ(‬
‫ﻓﺘﺤﺔ ﺃﻧﺒﻮﺏ ﺍﻟﺘﺼﺮﻳﻒ‬
‫‪ ٢٠‬ﻣﻢ‬
‫ﺍﻟﺼﺎﻣﻮﻟﺔ‬
‫ﺍﻟﻜﺘﻠﺔ‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻳﻤﻨﻊ ﺍﺳﺘﺨﺪﺍﻡ ﺯﻳﺖ ﻣﻌﺪﻧﻲ ﻋﻠﻰ ﺍﻷﺟﺰﺍء ﺍﻟﻤﺘﻮﻫﺠﺔ‪ .‬ﻭﻳﻤﻨﻊ ﺩﺧﻮﻝ ﺍﻟﺰﻳﺖ ﺍﻟﻤﻌﺪﻧﻲ ﺇﻟﻰ ﺩﺍﺧﻞ ﺍﻟﺠﻬﺎﺯ ﺣﻴﺚ ﻳﺘﺴﺒﺐ ﻫﺬﺍ ﻓﻲ ﺗﻘﻠﻴﻞ‬
‫ﺍﻟﻌﻤﺮ ﺍﻻﻓﺘﺮﺍﺿﻲ ﻟﻠﻮﺣﺪﺓ‪.‬‬
‫ﺃﺛﻨﺎء ﻟﺤﻢ ﺍﻷﻧﺎﺑﻴﺐ‪ ،‬ﺗﺄﻛﺪ ﻣﻦ ﻧﻔﺦ ﻏﺎﺯ ﻧﻴﺘﺮﻭﺟﻴﻦ ﺟﺎﻑ ﻓﻴﻬﺎ‪.‬‬
‫ﺍﻷﻃﻮﺍﻝ ﺍﻟﻘﺼﻮﻯ ﻟﻬﺬﺍ ﺍﻟﺠﻬﺎﺯ ﻣﻮﺿﺤﺔ ﻓﻲ ﺍﻟﺠﺪﻭﻝ ﺍﻟﺘﺎﻟﻲ‪ .‬ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﻤﺴﺎﻓﺔ ﺑﻴﻦ ﺍﻟﻮﺣﺪﺗﻴﻦ ﺃﺑﻌﺪ ﻣﻦ ﺫﻟﻚ‪ ،‬ﻻ ﻳﻤﻜﻦ ﺿﻤﺎﻥ‬
‫ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﺼﺤﻴﺢ‪.‬‬
‫ﺍﻟﻘﺎﻋﺪﺓ‬
‫‪ ١ ٤‬ﺍﺧﺘﻴﺎﺭ ﻣﺎﺩﺓ ﺍﻷﻧﺎﺑﻴﺐ‬
‫ﺃﻧﺒﻮﺏ ﺍﻟﺘﺼﺮﻳﻒ‬
‫‪ ٤ ٣‬ﺗﺮﻛﻴﺐ ﺍﻟﺘﺼﺮﻳﻒ‬
‫ﺗﻨﺒﻴﻪ‬
‫‪ ٥ ٣‬ﻗﻢ ﺑﺘﺄﻣﻴﻦ ﺍﻟﻮﺣﺪﺓ‬
‫ﻻ ﺗﺴﺘﺨﺪﻡ ﺍﻷﻧﺎﺑﻴﺐ ﺍﻟﻤﻮﺟﻮﺩﺓ ﺑﺎﻟﻔﻌﻞ‪.‬‬
‫ﺗﺤﺬﻳﺮ‬
‫ﻋﻨﺪ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻗﻢ ﺑﺘﺜﺒﻴﺘﻬﺎ ﺑﺸﻜﻞ ﺁﻣﻦ ﺣﻴﺚ ﺃﻧﻬﺎ ﻗﺪ ﺗﺘﻌﺮﺽ ﻟﺮﻳﺎﺡ ﺷﺪﻳﺪﺓ‪.‬‬
‫)ﺍﻟﻮﺣﺪﺓ‪ :‬ﻣﻢ(‬
‫ﻓﺘﺤﺔ ﻗﺪﺭ ﻗﻄﺮﻫﺎ ‪١٢-٢‬‬
‫ﺗﺪﻓﻖ ﺍﻟﻬﻮﺍء‬
‫ﻗﻢ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺃﻧﺎﺑﻴﺐ ﺗﺘﻤﺘﻊ ﺑﺠﻮﺍﻧﺐ ﺩﺍﺧﻠﻴﺔ ﻭﺧﺎﺭﺟﻴﺔ ﻧﻈﻴﻔﺔ ﺑﺪﻭﻥ ﺃﻱ ﺗﻠﻮﺙ ﻭﺍﻟﺬﻱ ﻗﺪ ﻳﺘﺴﺒﺐ ﻓﻲ ﺣﺪﻭﺙ ﻣﺸﻜﻼﺕ ﺃﺛﻨﺎء ﺍﻻﺳﺘﺨﺪﺍﻡ‬
‫ﻣﺜﻞ ﺍﻟﻜﺒﺮﻳﺖ ﺃﻭ ﺍﻷﻛﺴﻴﺪ ﺃﻭ ﺍﻷﺗﺮﺑﺔ ﺃﻭ ﺑﻘﺎﻳﺎ ﺍﻟﻘﺺ ﺃﻭ ﺍﻟﺰﻳﺖ ﺃﻭ ﺍﻟﻤﺎء‪.‬‬
‫ﻣﻦ ﺍﻟﻀﺮﻭﺭﻱ ﺍﺳﺘﺨﺪﺍﻡ ﺃﻧﺎﺑﻴﺐ ﻧﺤﺎﺱ ﻏﻴﺮ ﻣﻠﺤﻮﻣﺔ‪.‬‬
‫ﺍﻟﻤﻮﺍﺩ ‪ :‬ﺃﻧﺎﺑﻴﺐ ﻧﺤﺎﺱ ﻓﺴﻔﻮﺭﻱ ﻣﻨﺰﻭﻉ ﺍﻷﻛﺴﺠﻴﻦ ﻏﻴﺮ ﻣﻠﺤﻮﻣﺔ‪.‬‬
‫ﻣﻦ ﺍﻟﻤﺮﻏﻮﺏ ﻓﻴﻪ ﺃﻥ ﺗﻜﻮﻥ ﻛﻤﻴﺔ ﺍﻟﺰﻳﺖ ﺍﻟﻤﺘﺒﻘﻴﺔ ﺃﻗﻞ ﻣﻦ ‪ ٤٠‬ﻣﺠﻢ ‪ ١٠ /‬ﻡ‪.‬‬
‫ﻻ ﺗﺴﺘﺨﺪﻡ ﺃﻧﺎﺑﻴﺐ ﻧﺤﺎﺱ ﺗﺸﺘﻤﻞ ﻋﻠﻰ ﺟﺰء ﺗﻌﺮﺽ ﻟﻠﺜﻨﻲ ﺃﻭ ﺍﻟﺘﺸﻮﻩ ﺗﻐﻴﺮ ﺍﻟﻠﻮﻥ )ﻭﺧﺎﺻﺔ ﻋﻠﻰ ﺍﻟﺴﻄﺢ ﺍﻟﺪﺍﺧﻠﻲ(‪ .‬ﻭﺇﻻ ﻓﻘﺪ‬
‫ﻳﺘﻌﺮﺽ ﺻﻤﺎﻡ ﺍﻟﺘﻮﺳﻴﻊ ﺃﻭ ﺍﻷﻧﺒﻮﺏ ﺍﻟﺸﻌﺮﻱ ﺇﻟﻰ ﺍﻻﻧﺴﺪﺍﺩ ﺑﺴﺒﺐ ﺍﻟﻤﻠﻮﺛﺎﺕ‪.‬‬
‫ﺍﺧﺘﻴﺎﺭ ﺍﻷﻧﺎﺑﻴﺐ ﻏﻴﺮ ﻻﺋﻖ ﺳﻴﻘﻠﻞ ﻣﻦ ﺍﻷﺩﺍء‪ .‬ﺣﻴﺚ ﻳﺴﺘﺨﺪﻡ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء ‪ R410A‬ﻭﺍﻟﺬﻱ ﻳﺘﺤﻤﻞ ﺿﻐﻂ ﺃﻋﻠﻰ ﻣﻘﺎﺭﻧﺔ ﺑﺎﺳﺘﺨﺪﺍﻡ‬
‫ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻟﺘﻘﻠﻴﺪﻱ‪ ،‬ﻓﻤﻦ ﺍﻟﻀﺮﻭﺭﻱ ﺍﺧﺘﻴﺎﺭ ﻣﻮﺍﺩ ﻣﻼﺋﻤﺔ‪.‬‬
‫ﺳﻤﻚ ﺃﻧﺎﺑﻴﺐ ﺍﻟﻨﺤﺎﺱ ﺍﻟﻤﺴﺘﻌﻤﻠﺔ ﻣﻊ ‪ R410A‬ﻫﻲ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﻤﺒﻴﻦ ﻓﻲ ﺍﻟﺠﺪﻭﻝ‪.‬‬
‫ً‬
‫ﻣﻄﻠﻘﺎ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺃﻧﺎﺑﻴﺐ ﻧﺤﺎﺱ ﺃﺭﻕ ﻣﻦ ﺗﻠﻚ ﺍﻟﻮﺍﺭﺩﺓ ﻓﻲ ﺍﻟﺠﺪﻭﻝ ﺣﺘﻰ ﺇﺫﺍ ﻛﺎﻧﺖ ﻣﺘﺎﺣﺔ ﻓﻲ ﺍﻷﺳﻮﺍﻕ‪.‬‬
‫ﻻ ﺗﻘﻢ‬
‫‪٣٤٣‬‬
‫ﺳﻤﻚ ﺃﻧﺎﺑﻴﺐ ﺍﻟﻨﺤﺎﺱ ﺍﻟﻤﻘﻮﻳﺔ )‪(R410A‬‬
‫ﺍﻟﻘﻄﺮ ﺍﻟﺨﺎﺭﺟﻲ ﻟﻸﻧﺒﻮﺏ‬
‫]ﻣﻢ )ﺑﻮﺻﺔ([‬
‫ﺍﻟﺴﻤﺎﻛﺔ ]ﻣﻢ[‬
‫‪(١ / ٤) ٦٫٣٥‬‬
‫‪٦٠٣‬‬
‫‪(٣ / ٨) ٩٫٥٢‬‬
‫‪٠٫٨‬‬
‫‪(١ / ٢) ١٢٫٧٠‬‬
‫• ﻗﻢ ﺑﺘﺮﻛﻴﺐ ‪ ٤‬ﻣﺴﺎﻣﻴﺮ ﺗﺜﺒﻴﺖ ﻓﻲ ﺍﻟﻤﻮﺍﻗﻊ ﺍﻟﻤﻮﺿﺤﺔ ﺑﺎﻷﺳﻬﻢ ﻓﻲ ﺍﻟﺸﻜﻞ ﺃﻋﻼﻩ‪.‬‬
‫• ﻟﺘﻘﻠﻴﻞ ﺍﻻﻫﺘﺰﺍﺯ‪ ،‬ﻻ ﺗﻘﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﻋﻠﻰ ﺍﻷﺭﺽ ﻣﺒﺎﺷﺮﺓ ﻗﻢ ﺑﺘﺮﻛﺒﻴﻬﺎ ﻋﻠﻰ ﻗﺎﻋﺪﺓ ﺁﻣﻨﺔ )ﻣﺜﻞ ﺣﻮﺍﻣﻞ ﺧﺮﺳﺎﻧﻴﺔ(‪.‬‬
‫‪(٥ / ٨) ١٥٫٨٨‬‬
‫‪١٫٠‬‬
‫‪Ar-٤‬‬
‫‪29/3/2559 8:43:32‬‬
‫‪9381069118_IM_AR.indd 4‬‬
‫‪.٣.٢.٣‬‬
‫‪ ٢ ٣‬ﺃﺑﻌﺎﺩ ﺍﻟﺘﺮﻛﻴﺐ‬
‫)‪(١‬‬
‫ﺗﺮﻛﻴﺐ ﻭﺣﺪﺍﺕ ﺧﺎﺭﺟﻴﺔ ﻓﻲ ﻋﺪﺓ ﺻﻔﻮﻑ‬
‫)ﺍﻟﻮﺣﺪﺓ‪ :‬ﻣﻢ(‬
‫ﺗﺮﺗﻴﺐ ﻭﺣﺪﺍﺕ ﻓﺮﺩﻳﺔ ﻣﺘﻮﺍﺯﻳﺔ‬
‫ﺗﻮﻓﻴﺮ ﻣﺴﺎﺣﺔ ﺗﺮﻛﻴﺐ ﻛﺎﻓﻴﺔ ﻟﺴﻼﻣﺔ ﺍﻟﻤﻨﺘﺞ‪.‬‬
‫ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺍﻟﻔﺮﺩﻳﺔ‬
‫‪.١.٢.٣‬‬
‫ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﺍﻟﻤﺴﺎﺣﺔ ﺍﻟﻌﻠﻮﻳﺔ ﻣﻔﺘﻮﺣﺔ‪:‬‬
‫‪ ٣٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫)ﺍﻟﻮﺣﺪﺓ‪ :‬ﻣﻢ(‬
‫)‪ (١‬ﺍﻟﻌﻮﺍﺋﻖ ﻓﻲ ﺍﻟﺨﻠﻒ ﻓﻘﻂ‬
‫‪ ١٠٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫)‪ (٢‬ﺍﻟﻌﻮﺍﺋﻖ ﻓﻲ ﺍﻟﺨﻠﻒ ﻭﺍﻟﺠﻮﺍﻧﺐ ﻓﻘﻂ‬
‫‪ ٤٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ١٠٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫)‪(٢‬‬
‫‪ ٣٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫ﺗﺮﺗﻴﺐ ﻭﺣﺪﺍﺕ ﻣﺘﻌﺪﺩﺓ ﻣﺘﻮﺍﺯﻳﺔ‬
‫‪٢٠٠‬‬
‫ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٢٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٣٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٥٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٢٠٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٤٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ١٠٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫)‪ (٤‬ﺍﻟﻌﻮﺍﺋﻖ ﻓﻲ ﺍﻷﻣﺎﻡ ﻭﺍﻟﺨﻠﻒ ﻓﻘﻂ‬
‫)‪ (٣‬ﺍﻟﻌﻮﺍﺋﻖ ﻓﻲ ﺍﻷﻣﺎﻡ ﻓﻘﻂ‬
‫‪ ٣٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٦٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٦٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫)ﺍﻟﻮﺣﺪﺓ‪ :‬ﻣﻢ(‬
‫ﻋﻨﺪ ﻭﺟﻮﺩ ﻋﺎﺋﻖ ﻓﻲ ﺍﻟﻤﺴﺎﺣﺔ ﺍﻟﻌﻠﻮﻳﺔ‪:‬‬
‫)‪ (١‬ﺍﻟﻌﻮﺍﺋﻖ ﻓﻲ ﺍﻟﺨﻠﻒ ﻭﻓﻲ ﺍﻷﻋﻠﻰ ﻓﻘﻂ‬
‫)‪ (٢‬ﺍﻟﻌﻮﺍﺋﻖ ﻓﻲ ﺍﻟﺨﻠﻒ ﻭﻓﻲ ﺍﻟﺠﻮﺍﻧﺐ ﻭﻓﻲ ﺍﻷﻋﻠﻰ ﻓﻘﻂ‬
‫ﺑﺤﺪ ﺃﻗﺼﻰ‬
‫‪٥٠٠‬‬
‫ﺑﺤﺪ ﺃﻗﺼﻰ‬
‫‪٥٠٠‬‬
‫‪١٠٠٠‬‬
‫ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٥٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٦٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫ﻣﻼﺣﻈﺎﺕ‪:‬‬
‫• ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﻤﺴﺎﺣﺔ ﺃﻛﺒﺮ ﻣﻦ ﺗﻠﻚ ﺍﻟﻤﺬﻛﻮﺭﺓ ﺃﻋﻼﻩ‪ ،‬ﻓﺴﺘﻜﻮﻥ ﺍﻟﺸﺮﻭﻁ ﻫﻲ ﻧﻔﺲ ﺍﻟﺸﺮﻭﻁ ﺍﻟﻤﺘﺒﻌﺔ ﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﻭﺟﻮﺩ ﻋﻮﺍﺋﻖ‪.‬‬
‫• ﺍﻻﺭﺗﻔﺎﻉ ﻣﻦ ﻣﺴﺘﻮﻯ ﺍﻷﺭﺿﻴﺔ ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ‪ ٥٠‬ﻣﻢ ﺃﻭ ﺃﻛﺜﺮ‪.‬‬
‫• ﻋﻨﺪ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪ ،‬ﺗﺄﻛﺪ ﻣﻦ ﻓﺘﺢ ﺍﻟﺠﺎﻧﺒﻴﻦ ﺍﻷﻣﺎﻣﻲ ﻭﺍﻷﻳﺴﺮ ﻟﻠﺤﺼﻮﻝ ﻋﻠﻰ ﻛﻔﺎءﺓ ﺗﺸﻐﻴﻞ ﺃﻓﻀﻞ‪.‬‬
‫‪ ٣٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٣٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪٣٠٠‬‬
‫ﺃﻭ ﺃﻛﺜﺮ‬
‫‪.٢.٢.٣‬‬
‫‪٣٠٠‬‬
‫ﺃﻭ ﺃﻛﺜﺮ‬
‫ﺗﺮﻛﻴﺐ ﻋﺪﺓ ﻭﺣﺪﺍﺕ ﺧﺎﺭﺟﻴﺔ‬
‫• ﻳﺠﺐ ﺗﻮﻓﻴﺮ ﻣﺴﺎﺣﺔ ‪ ٢٥‬ﺳﻢ ﻋﻠﻰ ﺍﻷﻗﻞ ﺑﻴﻦ ﺍﻟﻮﺣﺪﺍﺕ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﺣﺎﻟﺔ ﺗﺮﻛﻴﺐ ﻋﺪﺓ ﻭﺣﺪﺍﺕ‪.‬‬
‫• ﻋﻨﺪ ﺗﻮﺟﻴﻪ ﺃﻧﺒﻮﺏ ﻣﻦ ﺟﺎﻧﺐ ﻭﺣﺪﺓ ﺧﺎﺭﺟﻴﺔ‪ ،‬ﻳﺠﺐ ﺗﻮﻓﻴﺮ ﻣﺴﺎﺣﺔ ﻟﺘﻮﺻﻴﻞ ﺍﻷﻧﺎﺑﻴﺐ‪.‬‬
‫• ﻳﺠﺐ ﻋﺪﻡ ﺗﺮﻛﻴﺐ ﺃﻛﺜﺮ ﻣﻦ ‪ ٣‬ﻭﺣﺪﺍﺕ ﺟﻨﺒًﺎ ﺇﻟﻰ ﺟﻨﺐ‪ .‬ﻋﻦ ﺗﺮﺗﻴﺐ ‪ ٣‬ﻭﺣﺪﺍﺕ ﺃﻭ ﺃﻛﺜﺮ ﻓﻲ ﺻﻒ ﻭﺍﺣﺪ‪ ،‬ﻳﺠﺐ ﺗﻮﻓﻴﺮ ﺍﻟﻤﺴﺎﺣﺔ‬
‫ﺍﻟﻤﺤﺪﺩﺓ ﻓﻲ ﺍﻟﻤﺜﺎﻝ ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻮﺩ ﻋﺎﺋﻖ ﻓﻲ ﺍﻟﻤﻨﻄﻘﺔ ﺍﻟﻌﻠﻴﺎ ً‬
‫ﺃﻳﻀﺎ‪.‬‬
‫)ﺍﻟﻮﺣﺪﺓ‪ :‬ﺳﻢ(‬
‫ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﺍﻟﻤﻨﻄﻘﺔ ﺍﻟﻌﻠﻴﺎ ﻣﻔﺘﻮﺣﺔ‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻻ ّ‬
‫ﺗﺮﻛﺐ ﻭﺣﺪﺓ ﺧﺎﺭﺟﻴﺔ ﺫﺍﺕ ﻣﺮﺣﻠﺘﻴﻦ ﺣﻴﺚ ﻗﺪ ﺗﺘﺠﻤﺪ ﻣﻴﺎﻩ ﺍﻟﺘﺼﺮﻳﻒ‪ .‬ﻭﺇﻻ ﻗﺪ ﺗﻜﻮّﻥ ﻣﻴﺎﻩ ﺍﻟﺘﺼﺮﻳﻒ ﺍﻟﻮﺍﺭﺩﺓ ﻣﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﻌﻠﻴﺎ‬
‫ﺛﻠﻮﺟﺎ ﻭﺗﺘﺴﺒﺐ ﻓﻲ ﺗﻌﻄﻞ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺴﻔﻠﻰ‬
‫ً‬
‫ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﺣﺮﺍﺭﺓ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ‪ ٣٢‬ﻓﻬﺮﻧﻬﻴﺖ )‪ (٠‬ﺩﺭﺟﺔ ﻣﺌﻮﻳﺔ ﺃﻭ ﺃﻗﻞ‪ ،‬ﻻ ﺗﺴﺘﺨﺪﻡ ﺃﻧﺒﻮﺏ ﺍﻟﺘﺼﺮﻳﻒ ﺍﻹﺿﺎﻓﻲ ﻭﻏﻄﺎء‬
‫ﺍﻟﺘﺼﺮﻳﻒ‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﺍﺳﺘﺨﺪﺍﻡ ﺃﻧﺒﻮﺏ ﺍﻟﺘﺼﺮﻳﻒ ﻭﻏﻄﺎء ﺍﻟﺘﺼﺮﻳﻒ‪ ،‬ﻗﺪ ﺗﺘﺠﻤﺪ ﻣﻴﺎﻩ ﺍﻟﺘﺼﺮﻳﻒ ﻓﻲ ﺍﻷﻧﺒﻮﺏ ﻓﻲ ﺍﻟﻤﻨﺎﺥ ﺷﺪﻳﺪ‬
‫ﺍﻟﺒﺮﻭﺩﺓ‪) .‬ﺧﺎﺹ ﺑﻄﺮﺍﺯ ﺍﻟﺪﻭﺭﺓ ﺍﻟﻌﻜﺴﻴﺔ ﻓﻘﻂ(‬
‫ﻓﻲ ﺍﻟﻤﻨﺎﻃﻖ ﺍﻟﺘﻲ ﻳﻜﺜﺮ ﻓﻴﻬﺎ ﺗﺴﺎﻗﻂ ﺍﻟﺠﻠﻴﺪ‪ ،‬ﺇﺫﺍ ﺗﻜﺪﺱ ﻣﻨﻔﺬ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻭﻣﺨﺮﺟﻬﺎ ﺑﺎﻟﺠﻠﻴﺪ‪ ،‬ﻓﻘﺪ ﺗﺼﻌﺐ ﺍﻟﺘﺪﻓﺌﺔ ﻭﻣﻦ ﺍﻟﻤﺤﺘﻤﻞ‬
‫ﺗﻌﻄﻞ ﺍﻟﻤﻨﺘﺞ‪ .‬ﻗﻢ ﺑﺈﻧﺸﺎء ﻗﺒﺔ ﺃﻭ ﻗﺎﻋﺪﺓ ﺃﻭ ﺿﻊ ﺍﻟﻮﺣﺪﺓ ﻋﻠﻰ ﺣﺎﻣﻞ ﻣﺮﺗﻔﻊ ﻳﺘﻢ ﺗﺜﺒﻴﺘﻪ ﻣﺤﻠﻴًﺎ‪.‬‬
‫)‪ (٢‬ﺍﻟﻌﻮﺍﺋﻖ ﻓﻲ ﺍﻷﻣﺎﻡ ﻓﻘﻂ‬
‫)‪ (١‬ﺍﻟﻌﻮﺍﺋﻖ ﻓﻲ ﺍﻟﺨﻠﻒ ﻓﻘﻂ‬
‫‪ ١٠٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٣٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫)‪ (٣‬ﺍﻟﻌﻮﺍﺋﻖ ﻓﻲ ﺍﻷﻣﺎﻡ ﻭﺍﻟﺨﻠﻒ ﻓﻘﻂ‬
‫‪ ٣ ٣‬ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ‬
‫ﺗﺤﺬﻳﺮ‬
‫‪ ٥٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ١٠٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫ﻓﻲ ﺣﺎﻟﺔ ﻭﺟﻮﺩ ﻋﺎﺋﻖ ﻓﻲ ﺍﻟﻤﻨﻄﻘﺔ ﺍﻟﻌﻠﻴﺎ ً‬
‫ﺃﻳﻀﺎ‬
‫)ﺍﻟﻮﺣﺪﺓ‪ :‬ﺳﻢ(‬
‫• ﺍﻟﻌﻮﺍﺋﻖ ﻓﻲ ﺍﻟﺨﻠﻒ ﻭﻓﻲ ﺍﻷﻋﻠﻰ ﻓﻘﻂ‬
‫ﺑﺤﺪ ﺃﻗﺼﻰ ‪٣٠٠‬‬
‫ﻻ ﺗﻘﻢ ﺑﻠﻤﺲ ﺍﻟﺰﻋﺎﻧﻒ‪.‬‬
‫ﻭﺑﺨﻼﻑ ﺫﻟﻚ‪ ،‬ﻳﻤﻜﻦ ﺃﻥ ﻳﺘﺴﺒﺐ ﻓﻲ ﺇﺻﺎﺑﺔ ﺷﺨﺼﻴﺔ‪.‬‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻋﻨﺪ ﺣﻤﻞ ﺍﻟﻮﺣﺪﺓ‪ ،‬ﺍﻣﺴﻚ ﺍﻟﻤﻘﺎﺑﺾ ﻋﻠﻰ ﺍﻟﺠﺎﻧﺒﻴﻦ ﺍﻷﻳﻤﻦ ﻭﺍﻷﻳﺴﺮ ﻭﻛﻦ ﺣﺮﻳﺼﺎ‪.‬‬
‫ﻓﻲ ﺣﺎﻟﺔ ﺣﻤﻞ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻣﻦ ﺃﺳﻔﻞ‪ ،‬ﻳﻤﻜﻦ ﺃﻥ ﺗﻀﻐﻂ ﻋﻠﻰ ﺍﻟﻴﺪﻳﻦ ﺃﻭ ﺍﻷﺻﺎﺑﻊ‪.‬‬
‫• ﺗﺄﻛﺪ ﻣﻦ ﺣﻤﻞ ﺍﻟﻮﺣﺪﺓ ﻣﻦ ﺍﻟﻤﻘﺎﺑﺾ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ ﺍﻟﺠﺎﻧﺒﻴﻦ‪ .‬ﻭﺑﺨﻼﻑ ﺫﻟﻚ‪ ،‬ﻗﺪ ﺗﺘﺸﻮﻩ ﺷﺒﻜﺔ ﺍﻷﻧﺎﺑﻴﺐ ﻋﻠﻰ ﺟﺎﻧﺒﻲ‬
‫ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫‪١٥٠٠‬‬
‫ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٥٠٠‬ﺃﻭ ﺃﻛﺜﺮ‬
‫‪Ar-٣‬‬
‫‪29/3/2559 8:43:32‬‬
‫‪9381069118_IM_AR.indd 3‬‬
‫‪ .٣‬ﺃﻋﻤﺎﻝ ﺍﻟﺘﺮﻛﻴﺐ‬
‫ﺗﺤﺬﻳﺮ‬
‫•‬
‫•‬
‫•‬
‫•‬
‫ﺣﻴﺚ ﺃﻥ ﺿﻐﻂ ﺍﻟﻌﻤﻞ ﺃﻋﻠﻰ ﺑﻘﺪﺭ ‪ ١٫٦‬ﻣﺮﺓ ﻣﻦ ﻃﺮﺍﺯﺍﺕ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻟﺘﻘﻠﻴﺪﻱ )‪ ،(R22‬ﻓﺒﻌﺾ ﺍﻷﻧﺎﺑﻴﺐ ﻭﺍﻟﺘﺮﻛﻴﺐ‬
‫ﻭﺃﺩﻭﺍﺕ ﺍﻟﺼﻴﺎﻧﺔ ﺗﻜﻮﻥ ﺧﺎﺻﺔ‪) .‬ﺍﻧﻈﺮ ﺍﻟﺠﺪﻭﻝ ﺃﺩﻧﺎﻩ(‪.‬‬
‫ﺑﺸﻜﻞ ﺧﺎﺹ‪ ،‬ﻋﻨﺪ ﺍﺳﺘﺒﺪﺍﻝ ﻃﺮﺍﺯﺍﺕ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻟﺘﻘﻠﻴﺪﻱ )‪ (R22‬ﺑﻄﺮﺍﺯﺍﺕ ﺳﺎﺋﻞ ﺗﺒﺮﻳﺪ ‪ R410A‬ﺍﻟﺠﺪﻳﺪ‪ ،‬ﻗﻢ ﺩﺍﺋﻤﺎ‬
‫ﺑﺎﺳﺘﺒﺪﺍﻝ ﺍﻷﻧﺎﺑﻴﺐ ﺍﻟﺘﻘﻠﻴﺪﻳﺔ ﻭﺻﺎﻣﻮﻳﻞ ﺍﻟﺘﻮﺳﻴﻊ ﺑﺄﻧﺎﺑﻴﺐ ﻭﺻﺎﻣﻮﻳﻞ ‪.R410A‬‬
‫ﺍﻟﻄﺮﺍﺯﺍﺕ ﺍﻟﺘﻲ ﺗﺴﺘﻌﻤﻞ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪ R410A‬ﻟﻬﺎ ﻣﻨﻔﺬ ﺷﺤﻦ ﻣﺨﺘﻠﻒ ﺫﻭ ﻗﻄﺮ ﻣﺴﻨﻦ ﻟﻤﻨﻊ ﺍﻟﺸﺤﻦ ﺍﻟﺨﺎﻃﺊ ﺑﺴﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‬
‫ﺍﻟﺘﻘﻠﻴﺪﻱ )‪ .(R22‬ﻟﺬﻟﻚ‪ ،‬ﺗﺤﻘﻖ ﻣﺴﺒﻘﺎ‪] .‬ﻣﻨﻔﺬ ﺍﻟﺸﺤﻦ ﺫﻭ ﺍﻟﻘﻄﺮ ﺍﻟﻤﺴﻨﻦ ﺍﻟﺨﺎﺹ ﺑﺴﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪ R410A‬ﻫﻮ ‪ ٢٠-١/٢‬ﺳﻦ‬
‫ﻧﺎﻋﻢ ﻣﻮﺣﺪ‪[.‬‬
‫ﻛﻦ ﺣﺮﺻﺎً ﻋﻠﻰ ﻋﺪﻡ ﺩﺧﻮﻝ ﻣﻮﺍﺩ ﻏﺮﻳﺒﺔ )ﺍﻟﺰﻳﺖ‪ ،‬ﺍﻟﻤﻴﺎﻩ‪ ،‬ﺇﻟﺦ( ﻓﻲ ﺍﻷﻧﺎﺑﻴﺐ ﺃﻛﺜﺮ ﻣﻦ ﺣﺮﺻﻚ ﻓﻲ ﻃﺮﺍﺯﺍﺕ ﺍﻟﺴﻮﺍﺋﻞ‬
‫ﺍﻟﺘﻘﻠﻴﺪﻳﺔ‪ .‬ﺃﻳﻀﺎ‪ ،‬ﻋﻨﺪ ﺗﺨﺰﻳﻦ ﺍﻟﻤﻮﺍﺳﻴﺮ‪ ،‬ﺍﺧﺘﻢ ﺍﻟﻔﺘﺤﺎﺕ ﺑﺸﻜﻞ ﺁﻣﻦ ﻋﻦ ﻃﺮﻳﻖ ﺍﻟﺸﺪ‪ ،‬ﺍﻟﻠﺼﻖ‪ ،‬ﺍﻟﺦ‪.‬‬
‫ﻋﻨﺪ ﺷﺤﻦ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺧﺬ ﻓﻲ ﺍﻻﻋﺘﺒﺎﺭ ﺍﻟﺘﻐﻴﺮ ﺍﻟﻄﻔﻴﻒ ﻓﻲ ﺗﺮﻛﻴﺐ ﺍﻟﻐﺎﺯ ﻭﻣﺮﺍﺣﻞ ﺍﻟﺴﺎﺋﻞ‪ .‬ﻭﺍﺷﺤﻦ ﺩﺍﺋﻤﺎ ﻣﻦ ﻣﺮﺣﻠﺔ‬
‫ﺍﻟﺴﺎﺋﻞ ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ ﺗﺮﻛﻴﺐ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻣﺴﺘﻘﺮ‪.‬‬
‫ﺗﺄﻛﺪ ﻣﻦ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﻣﻮﺍﻓﻘﺔ ﺍﻟﻌﻤﻴﻞ ﻻﺧﺘﻴﺎﺭ ﻭﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪.‬‬
‫‪ ١ ٣‬ﺍﺧﺘﻴﺎﺭ ﻣﻮﻗﻊ ﺍﻟﺘﺜﺒﻴﺖ‬
‫ﺗﺤﺬﻳﺮ‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﻣﻜﺎﻥ ﻳﻤﻜﻨﻪ ﺗﺤﻤّﻞ ﻭﺯﻥ ﺍﻟﻮﺣﺪﺓ‪ .‬ﻭﺑﺨﻼﻑ ﺫﻟﻚ‪ ،‬ﻗﺪ ﺗﺴﻘﻂ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻭﺗﺘﺴﺒﺐ ﻓﻲ ﺇﺻﺎﺑﺔ‪.‬‬
‫ﺗﺄﻛﺪ ﻣﻦ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﻤﻮﺿﺢ‪ ،‬ﺑﺤﻴﺚ ﻳﻤﻜﻨﻬﺎ ﺗﺤﻤﻞ ﺍﻟﺰﻻﺯﻝ ﻭﺍﻟﺘﻴﻔﻮﻧﺎﺕ ﻭﺍﻟﺮﻳﺎﺡ ﺍﻟﻘﻮﻳﺔ ﺍﻷﺧﺮﻯ‪ .‬ﻳﻤﻜﻦ‬
‫ﺃﻥ ﻳﺘﺴﺒﺐ ﺍﻟﺘﺮﻛﻴﺐ ﻏﻴﺮ ﺍﻟﺼﺤﻴﺢ ﻓﻲ ﺍﻧﻘﻼﺏ ﺃﻭ ﺳﻘﻮﻁ ﺍﻟﻮﺣﺪﺓ ﺃﻭ ﺣﻮﺍﺩﺙ ﺃﺧﺮﻯ‪.‬‬
‫ﻻ ﺗﻘﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺑﺎﻟﻘﺮﺏ ﻣﻦ ﺣﺎﻓﺔ ﺷﺮﻓﺔ‪ .‬ﻭﺑﺨﻼﻑ ﺫﻟﻚ‪ ،‬ﻗﺪ ﻳﺘﺴﻠﻖ ﺍﻷﻃﻔﺎﻝ ﻋﻠﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻭﻳﺴﻘﻄﻮﻥ‬
‫ﻣﻦ ﻋﻠﻰ ﺍﻟﺸﺮﻓﺔ‪.‬‬
‫‪ ٢ ٢‬ﺃﺩﻭﺍﺕ ﺧﺎﺻﺔ ﻟﺴﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪R410A‬‬
‫ﺗﻨﺒﻴﻪ‬
‫ﺗﺤﺬﻳﺮ‬
‫ﻟﺘﺮﻛﻴﺐ ﻭﺣﺪﺓ ﺗﺴﺘﻌﻤﻞ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪ ،R410A‬ﺍﺳﺘﺨﺪﺍﻡ ﺍﻷﺩﻭﺍﺕ ﺍﻟﻤﺨﺼﺼﺔ ﻭﻣﻮﺍﺩ ﺍﻷﻧﺎﺑﻴﺐ ﺍﻟﺘﻲ ﺗﻢ ﺗﺼﻨﻴﻌﻬﺎ ﺧﺼﻴﺼﺎ‬
‫ﻻﺳﺘﻌﻤﺎﻝ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪ .R410A‬ﻷﻥ ﺿﻐﻂ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪ R410A‬ﺃﻋﻠﻰ ﺑﻤﻘﺪﺍﺭ ‪ ١٫٦‬ﻣﺮﺓ ﺗﻘﺮﻳﺒﺎ ﻣﻦ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪،R22‬‬
‫ﻳﻤﻜﻦ ﺃﻥ ﻳﺘﺴﺒﺐ ﻋﺪﻡ ﺍﺳﺘﺨﺪﺍﻡ ﻣﻮﺍﺩ ﺍﻷﻧﺎﺑﻴﺐ ﺍﻟﻤﺨﺼﺼﺔ ﺃﻭ ﺍﻟﺘﺮﻛﻴﺐ ﻏﻴﺮ ﺻﺤﻴﺢ ﻓﻲ ﺣﺪﻭﺙ ﺗﻤﺰﻕ ﺃﻭ ﺇﺻﺎﺑﺔ‪ .‬ﻋﻼﻭﺓ ﻋﻠﻰ‬
‫ﺫﻟﻚ‪ ،‬ﻳﻤﻜﻦ ﺃﻥ ﻳﺘﺴﺒﺐ ﻓﻲ ﻭﻗﻮﻉ ﺣﻮﺍﺩﺙ ﺧﻄﻴﺮﺓ ﻣﺜﻞ ﺗﺴﺮﺏ ﻣﺎء ﺃﻭ ﺻﺪﻣﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ‪ ،‬ﺃﻭ ﺣﺮﻳﻖ‪.‬‬
‫ﺍﻟﺘﻐﻴﻴﺮﺍﺕ‬
‫ﺍﺳﻢ ﺍﻷﺩﺍﺓ‬
‫ﻣﺸﻌﺐ ﺍﻟﻌﺪﺍﺩﺍﺕ‬
‫ﺍﻟﻀﻐﻂ ﻣﺮﺗﻔﻊ‪ ،‬ﻭﻻ ﻳﻤﻜﻦ ﻗﻴﺎﺳﻪ ﺑﻤﻘﻴﺎﺱ ﺗﻘﻠﻴﺪﻱ‪ .‬ﻟﻤﻨﻊ ﺍﻻﺧﺘﻼﻁ ﺍﻟﺨﺎﻃﺌﺔ ﻟﺴﻮﺍﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‬
‫ﺍﻷﺧﺮﻯ‪ ،‬ﺗﻢ ﺗﻐﻴﻴﺮ ﻗﻄﺮ ﻛﻞ ﻣﻨﻔﺬ‪.‬‬
‫ﻣﻦ ﺍﻟﻤﻮﺻﻰ ﺍﺳﺘﻌﻤﺎﻝ ﻣﺴﺘﺸﻌﺮ ﺑﻪ ﻋﻮﺍﺯﻝ ‪ –٠٫١‬ﺇﻟﻰ ‪ ٥٫٣‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ )‪ –١‬ﺇﻟﻰ ‪ ٥٣‬ﺑﺎﺭ(‬
‫ﻟﻠﻀﻐﻂ ﺍﻟﻌﺎﻟﻲ‪ –٠٫١ .‬ﺇﻟﻰ ‪ ٣٫٨‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ )‪ –١‬ﺇﻟﻰ ‪ ٣٨‬ﺑﺎﺭ( ﻟﻠﻀﻐﻂ ﺍﻟﻌﺎﻟﻲ‪.‬‬
‫ﺧﺮﻃﻮﻡ ﺍﻟﺸﺤﻦ‬
‫ﻟﺰﻳﺎﺩﺓ ﻣﻘﺎﻭﻣﺔ ﺍﻟﻀﻐﻂ‪ ،‬ﺗﻢ ﺗﻐﻴﻴﺮ ﻣﺎﺩﺓ ﺍﻟﺨﺮﻃﻮﻡ ﻭﺣﺠﻢ ﺍﻟﻘﺎﻋﺪﺓ‪.‬‬
‫ﻣﻀﺨﺔ ﺍﻟﻬﻮﺍء‬
‫ﻳﻤﻜﻦ ﺃﻥ ﺗﺴﺘﺨﺪﻡ ﻣﻀﺨﺔ ﻫﻮﺍء ﺗﻘﻠﻴﺪﻳﺔ ﻋﻦ ﻃﺮﻳﻖ ﺗﺮﻛﻴﺐ ﻣﺤﻮﻝ ﻣﻀﺨﺔ ﻫﻮﺍء‪.‬‬
‫ﻣﻜﺘﺸﻒ ﺗﺴﺮﺏ ﺍﻟﻐﺎﺯ‬
‫ﻛﺎﺷﻒ ﺗﺮﺳﺐ ﻏﺎﺯ ﺧﺎﺹ ﻟﺴﺎﺋﻞ ﺗﺒﺮﻳﺪ ﺍﻟﻬﻴﺪﺭﻭﻭﻓﻠﻮﺭﻭﻛﺮﺑﻮﻥ ‪.R410A‬‬
‫ﺃﻧﺎﺑﻴﺐ ﻧﺤﺎﺱ‬
‫ﻣﻦ ﺍﻟﻀﺮﻭﺭﻱ ﺍﺳﺘﺨﺪﺍﻡ ﺃﻧﺎﺑﻴﺐ ﻧﺤﺎﺱ ﻏﻴﺮ ﻣﻠﺤﻮﻣﺔ ﻭﻣﻦ ﺍﻟﻤﺮﻏﻮﺏ ﺃﻥ ﺗﻜﻮﻥ ﻛﻤﻴﺔ ﺍﻟﺰﻳﺖ ﺃﻗﻞ ﻣﻦ ‪ ٤٠‬ﻣﻠﺠﻢ‪ ١٠/‬ﻡ‪ .‬ﻻ ﺗﺴﺘﺨﺪﻡ‬
‫ﺃﻧﺎﺑﻴﺐ ﻧﺤﺎﺱ ﺗﺸﺘﻤﻞ ﻋﻠﻰ ﺟﺰء ﺗﻌﺮﺽ ﻟﻠﺜﻨﻲ ﺃﻭ ﺍﻟﺘﺸﻮﻩ ﺗﻐﻴﺮ ﺍﻟﻠﻮﻥ )ﺧﺎﺻﺔ ﻋﻠﻰ ﺍﻟﺴﻄﺢ ﺍﻟﺪﺍﺧﻠﻲ(‪ .‬ﻭﺑﺨﻼﻑ ﺫﻟﻚ‪ ،‬ﻗﺪ ﻳُﺴﺪ ﺻﻤﺎﻡ‬
‫ﺍﻟﺘﻮﺳﻴﻊ ﺃﻭ ﺍﻷﻧﺒﻮﺏ ﺍﻟﺸﻌﺮﻱ ﻣﻦ ﺍﻟﻤﻠﻮﺛﺎﺕ‪.‬‬
‫ﺣﻴﺚ ﺃﻥ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء ﺍﻟﺬﻱ ﻳﻌﻤﻞ ﺑﺴﺎﺋﻞ ﺗﺒﺮﻳﺪ ‪ R410A‬ﻳﺘﺤﻤﻞ ﺿﻐﻂ ﺃﻋﻠﻰ ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ ﺳﺎﺋﻞ ﺗﺒﺮﻳﺪ ﺗﻘﻠﻴﺪﻱ‪ ،‬ﻓﻤﻦ ﺍﻟﻀﺮﻭﺭﻱ‬
‫ﺍﺧﺘﻴﺎﺭ ﺍﻟﻤﻮﺍﺩ ﺍﻟﻤﻼﺋﻤﺔ‪.‬‬
‫ﺳﻤﻚ ﺃﻧﺎﺑﻴﺐ ﺍﻟﻨﺤﺎﺱ ﺍﻟﻤﺴﺘﻌﻤﻠﺔ ﻣﻊ ‪ R410A‬ﻫﻲ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﻤﺒﻴﻦ ﻓﻲ ﺍﻟﺠﺪﻭﻝ‪ .‬ﻻ ﺗﺴﺘﻌﻤﻞ ﺃﺑﺪﺍ ﺃﻧﺎﺑﻴﺐ ﻧﺤﺎﺱ ﺃﺭﻕ ﻣﻦ ﺗﻠﻚ‬
‫ﺍﻟﻮﺍﺭﺩﺓ ﻓﻲ ﺍﻟﺠﺪﻭﻝ ﺣﺘﻰ ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﻣﺘﻮﻓﺮﺓ ﻓﻲ ﺍﻟﺴﻮﻕ‪.‬‬
‫ﻻ ﺗﻘﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﺍﻟﻤﻨﺎﻃﻖ ﺍﻟﺘﺎﻟﻴﺔ‪:‬‬
‫• ﺍﻟﻤﻨﻄﻘﺔ ﺍﻟﺘﻲ ﺑﻬﺎ ﻣﺤﺘﻮﻳﺎﺕ ﻣﻠﺢ ﻋﺎﻟﻴﺔ‪ ،‬ﻣﺜﻞ ﺷﺎﻃﺊ ﺍﻟﺒﺤﺮ‪ .‬ﺳﺘﺆﺩﻱ ﺇﻟﻰ ﺗﺪﻫﻮﺭ ﺍﻷﺟﺰﺍء ﺍﻟﻤﻌﺪﻧﻴﺔ‪ ،‬ﻣﻤﺎ ﻳﺘﺴﺒﺐ ﻓﻲ ﺗﻌﻄﻞ‬
‫ﺍﻷﺟﺰﺍء ﺃﻭ ﺣﺪﻭﺙ ﺗﺴﺮﺏ ﻣﺎء ﻓﻲ ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫• ﺍﻟﻤﻨﻄﻘﺔ ﺍﻟﻤﻠﻴﺌﺔ ﺑﺎﻟﺰﻳﻮﺕ ﺍﻟﻤﻌﺪﻧﻴﺔ ﺃﻭ ﺍﻟﺘﻲ ﺗﺤﺘﻮﻱ ﻋﻠﻰ ﻛﻤﻴﺔ ﻛﺒﻴﺮﺓ ﻣﻦ ﺍﻟﺰﻳﺖ ﺍﻟﻤﻠﻄﺦ ﺃﻭ ﺍﻟﺒﺨﺎﺭ‪ ،‬ﻣﺜﻞ ﺍﻟﻤﻄﺒﺦ‪ .‬ﺳﺘﺆﺩﻱ ﺇﻟﻰ‬
‫ﺗﺪﻫﻮﺭ ﺍﻷﺟﺰﺍء ﺍﻟﺒﻼﺳﺘﻴﻜﻴﺔ‪ ،‬ﻣﻤﺎ ﻳﺘﺴﺒﺐ ﻓﻲ ﺗﻌﻄﻞ ﺍﻷﺟﺰﺍء ﺃﻭ ﺣﺪﻭﺙ ﺗﺴﺮﺏ ﻣﺎء ﻓﻲ ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫• ﺍﻟﻤﻨﻄﻘﺔ ﺍﻟﺘﻲ ﺗﻮﻟﺪ ﻣﻮﺍﺩ ﺗﺆﺛﺮ ﺳﻠﺒﺎ ﻋﻠﻰ ﺍﻟﺠﻬﺎﺯ‪ ،‬ﻣﺜﻞ ﻏﺎﺯ ﺍﻟﻜﺒﺮﻳﺘﻴﻚ ﺃﻭ ﻏﺎﺯ ﺍﻟﻜﻠﻮﺭ ﺃﻭ ﺍﻷﺣﻤﺎﺽ ﺃﻭ ﺍﻟﻘﻠﻮﻳﺎﺕ‪ .‬ﺳﺘﺘﺴﺒﺐ ﻓﻲ‬
‫ﺗﺂﻛﻞ ﺃﻧﺎﺑﻴﺐ ﺍﻟﻨﺤﺎﺱ ﻭﺍﻟﻤﻔﺎﺻﻞ ﺍﻟﻤﻜﺴﻮﺓ ﺑﺎﻟﻨﺤﺎﺱ‪ ،‬ﻣﻤﺎ ﻳﻤﻜﻦ ﺃﻥ ﺗﺘﺴﺒﺐ ﻓﻲ ﺗﺴﺮﺏ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫• ﺍﻟﻤﻨﻄﻘﺔ ﺍﻟﺘﻲ ﺗﺤﺘﻮﻱ ﻋﻠﻰ ﻣﻌﺪﺍﺕ ﺗﻮﻟﺪ ﺗﺪﺍﺧﻞ ﻛﻬﺮﻭﻣﻐﻨﺎﻃﻴﺴﻲ‪ .‬ﺳﺘﺘﺴﺒﺐ ﻓﻲ ﺗﻌﻄﻞ ﻧﻈﺎﻡ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﺍﻟﻌﻤﻞ‪ ،‬ﻣﻤﺎ ﻳﻤﻨﻊ‬
‫ﺍﻟﻮﺣﺪﺓ ﻣﻦ ﺍﻟﻌﻤﻞ ﺑﺸﻜﻞ ﻃﺒﻴﻌﻲ‪.‬‬
‫• ﺍﻟﻤﻨﻄﻘﺔ ﺍﻟﺘﻲ ﻳﻤﻜﻦ ﺃﻥ ﺗﺘﺴﺒﺐ ﻓﻲ ﺗﺴﺮﻳﺐ ﻏﺎﺯ ﻗﺎﺑﻞ ﻟﻼﺣﺘﺮﺍﻕ ﺃﻭ ﺍﻟﺘﻲ ﺗﺤﺘﻮﻱ ﻋﻠﻰ ﺃﻟﻴﺎﻑ ﺍﻟﻜﺮﺑﻮﻥ ﺍﻟﻤﻌﻠﻘﺔ ﺃﻭ ﻏﺒﺎﺭ ﻗﺎﺑﻞ‬
‫ﻟﻼﺷﺘﻌﺎﻝ ﺃﻭ ﻣﻮﺍﺩ ﻣﻠﺘﻬﺒﺔ ﻣﺘﻄﺎﻳﺮﺓ ﻣﺜﻞ ﻣﺨﻔﻒ ﺍﻟﻄﻼء ﺃﻭ ﺍﻟﺒﻨﺰﻳﻦ‪ .‬ﺇﺫﺍ ﺗﺴﺮﺏ ﺍﻟﻐﺎﺯ ﻭﺍﺳﺘﻘﺮ ﺣﻮﻝ ﺍﻟﻮﺣﺪﺓ‪ ،‬ﻓﺈﻧﻪ ﻳﻤﻜﻦ ﺃﻥ‬
‫ﻳﺴﺒﺐ ﺣﺮﻳﻘﺎ‪.‬‬
‫• ﺍﻟﻤﻨﻄﻘﺔ ﺍﻟﺘﻲ ﻗﺪ ﺗﻌﻴﺶ ﻓﻴﻬﺎ ﺣﻴﻮﺍﻧﺎﺕ ﺻﻐﻴﺮﺓ‪ .‬ﻗﺪ ﻳﺤﺪﺙ ﺗﻌﻄﻴﻞ‪ ،‬ﺃﻭ ﺩﺧﺎﻥ‪ ،‬ﺃﻭ ﺣﺮﻳﻖ ﺇﺫﺍ ﺩﺧﻠﺖ ﺍﻟﺤﻴﻮﺍﻧﺎﺕ ﺍﻟﺼﻐﻴﺮﺓ ﺇﻟﻰ‬
‫ﺍﻷﺟﺰﺍء ﺍﻹﻟﻜﺘﺮﻭﻧﻴﺔ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺃﻭ ﻻﻣﺴﺘﻬﺎ‪.‬‬
‫• ﺍﻟﻤﻨﻄﻘﺔ ﺍﻟﺘﻲ ﻗﺪ ﻳﺘﺒﻮﻝ ﻓﻴﻬﺎ ﺍﻟﺤﻴﻮﺍﻧﺎﺕ ﻋﻠﻰ ﺍﻟﻮﺣﺪﺓ ﺃﻭ ﻗﺪ ﺗﺘﻮﻟﺪ ﻓﻴﻬﺎ ﺍﻷﻣﻮﻧﻴﺎ‪.‬‬
‫ﻻ ﺗﻘﻢ ﺑﺈﻣﺎﻟﺔ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻷﻛﺜﺮ ﻣﻦ ‪ ٣‬ﺩﺭﺟﺎﺕ‪ .‬ﻭﻣﻊ ﺫﻟﻚ‪ ،‬ﻻ ﺗﻘﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺑﻤﻴﻞ ﺍﺗﺠﺎﻩ ﺍﻟﺠﺎﻧﺐ ﺍﻟﺬﻱ ﻳﺤﺘﻮﻱ ﻋﻠﻰ‬
‫ﺍﻟﻀﺎﻏﻂ‪.‬‬
‫ﺭﻛﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﻣﻜﺎﻥ ﺟﻴﺪ ﺍﻟﺘﻬﻮﻳﺔ ﺑﻌﻴﺪﺍ ﻋﻦ ﺍﻷﻣﻄﺎﺭ ﺃﻭ ﺿﻮء ﺍﻟﺸﻤﺲ ﺍﻟﻤﺒﺎﺷﺮ‪.‬‬
‫ﺇﺫﺍ ﻛﺎﻥ ﻳﺠﺐ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﻣﻨﻄﻘﺔ ﻳﻤﻜﻦ ﻭﺻﻮﻝ ﻋﺎﻣﺔ ﺍﻟﻨﺎﺱ ﺇﻟﻴﻬﺎ ﺑﺴﻬﻮﻟﺔ‪ ،‬ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺳﻴﺎﺝ ﺣﻤﺎﻳﺔ ﺣﺴﺐ‬
‫ﺍﻟﻀﺮﻭﺭﺓ ﺃﻭ ﻣﺎ ﺷﺒﻪ ﺫﻟﻚ ﻟﻤﻨﻊ ﻭﺻﻮﻟﻬﻢ ﺇﻟﻰ ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﻣﻜﺎﻥ ﻳﻜﻮﻥ ﻣﻼﺋﻢ ﻟﺠﻴﺮﺍﻧﻚ‪ ،‬ﺣﻴﺚ ﻗﺪ ﻳﺘﺄﺛﺮ ﺃﻱ ﻣﻨﻬﻢ ﺑﺘﺪﻓﻖ ﺍﻟﻬﻮﺍء ﺍﻟﻤﻨﺒﻌﺚ ﻣﻦ ﺍﻟﻤﻨﻔﺬ ﺃﻭ‬
‫ﺍﻟﻀﻮﺿﺎء ﺃﻭ ﺍﻻﻫﺘﺰﺍﺯ‪ .‬ﺇﺫﺍ ﻛﺎﻥ ﻳﺠﺐ ﺗﺮﻛﺒﻴﻬﺎ ﺑﺎﻟﻘﺮﺏ ﻣﻦ ﺍﻟﺠﻴﺮﺍﻥ‪ ،‬ﻓﺘﺄﻛﺪ ﻣﻦ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﻣﻮﺍﻓﻘﺘﻬﻢ‪.‬‬
‫ﺇﺫﺍ ﺗﻢ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﻣﻨﻄﻘﺔ ﺑﺎﺭﺩﺓ ﺗﺘﺄﺛﺮ ﺑﺘﺠﻤﻊ ﺍﻟﺠﻠﻴﺪ‪ ،‬ﺃﻭ ﻫﻄﻮﻝ ﺍﻟﺠﻠﻴﺪ‪ ،‬ﺃﻭ ﺍﻟﺘﺠﻤﻴﺪ‪ ،‬ﺍﺗﺨﺬ ﺍﻟﺘﺪﺍﺑﻴﺮ ﺍﻟﻤﻨﺎﺳﺒﺔ‬
‫ﻟﺤﻤﺎﻳﺘﻬﺎ ﻣﻦ ﻫﺬﻩ ﺍﻟﻌﻨﺎﺻﺮ‪.‬‬
‫ﻟﻀﻤﺎﻥ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻤﺴﺘﻘﺮ‪ ،‬ﺭﻛﺐ ﻗﻨﻮﺍﺕ ﺍﻟﺪﺧﻮﻝ ﻭﺍﻟﺨﺮﻭﺝ‪.‬‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﻣﻜﺎﻥ ﺑﻌﻴﺪ ﻋﻦ ﺍﻟﻌﺎﺩﻡ ﺃﻭ ﻣﻨﺎﻓﺬ ﺍﻹﺧﺮﺍﺝ ﺍﻟﺘﻲ ﺗﻌﻤﻞ ﻋﻠﻰ ﺗﻔﺮﻳﻎ ﺍﻟﺒﺨﺎﺭ ﺃﻭ ﺍﻟﺴﺨﺎﻡ ﺃﻭ ﺍﻷﺗﺮﺑﺔ ﺃﻭ‬
‫ﺍﻟﻨﺴﺎﻟﺔ‪.‬‬
‫ﺳﻤﻚ ﺃﻧﺎﺑﻴﺐ ﺍﻟﻨﺤﺎﺱ ﺍﻟﻤﻘﻮﻳﺔ )‪(R410A‬‬
‫ﺍﻟﻘﻄﺮ ﺍﻟﺨﺎﺭﺟﻲ ﻟﻸﻧﺒﻮﺏ ]ﻣﻢ )ﺑﻮﺻﺔ([‬
‫ﺍﻟﺴﻤﺎﻛﺔ ]ﻣﻢ[‬
‫‪(١ / ٤) ٦٫٣٥‬‬
‫‪٠٫٨٠‬‬
‫‪(٣ / ٨) ٩٫٥٢‬‬
‫‪٠٫٨٠‬‬
‫‪(١ / ٢) ١٢٫٧٠‬‬
‫‪٠٫٨٠‬‬
‫‪(٥ / ٨) ١٥٫٨٨‬‬
‫‪١٫٠٠‬‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‪ ،‬ﻭﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪ ،‬ﻭﻛﺒﻞ ﺍﻹﻣﺪﺍﺩ ﺑﺎﻟﺘﻴﺎﺭ‪ ،‬ﻭﺳﻠﻚ ﺍﻟﻨﻘﻞ‪ ،‬ﻭﺳﻠﻚ ﺍﻟﺘﺤﻜﻢ ﻋﻦ ﺑُﻌﺪ ﻋﻠﻰ ﻣﺴﺎﻓﺔ ‪ ١‬ﻣﺘﺮ‬
‫ﻋﻠﻰ ﺍﻷﻗﻞ ﻣﻦ ﺟﻬﺎﺯ ﺍﻟﺘﻠﻔﺰﻳﻮﻥ ﺃﻭ ﺟﻬﺎﺯ ﺍﻟﺮﺍﺩﻳﻮ‪ .‬ﺍﻟﻐﺮﺽ ﻣﻦ ﻫﺬﺍ ﻫﻮ ﻣﻨﻊ ﺍﻟﺘﺪﺧﻞ ﻣﻊ ﺍﺳﺘﻘﺒﺎﻝ ﺇﺷﺎﺭﺓ ﺍﻟﺘﻠﻔﺰﻳﻮﻥ ﺃﻭ ﺣﺪﻭﺙ‬
‫ﺿﻮﺿﺎء ﺑﺎﺳﺘﻘﺒﺎﻝ ﺍﻟﺮﺍﺩﻳﻮ‪) .‬ﺣﺘﻰ ﻭﻟﻮ ﻛﺎﻧﺖ ﻣﺮﻛﺒﺔ ﻋﻠﻰ ﺑﻌﺪ ﺃﻛﺜﺮ ﻣﻦ ‪ ١‬ﻣﺘﺮ‪ ،‬ﻻ ﻳﺰﺍﻝ ﻳﻤﻜﻨﻚ ﺍﺳﺘﻘﺒﺎﻝ ﺿﻮﺿﺎء ﺗﺤﺖ ﺑﻌﺾ‬
‫ﻇﺮﻭﻑ ﺍﻹﺷﺎﺭﺓ(‪.‬‬
‫ﻣﻔﺘﺎﺡ ﻓﺮﻋﻲ ﻭﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ‬
‫‪ ١‬ﻣﺘﺮ ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ١‬ﻣﺘﺮ ﺃﻭ ﺃﻛﺜﺮ‬
‫‪ ٣ ٢‬ﻣﻠﺤﻘﺎﺕ‬
‫ﻣﻔﺘﺎﺡ ﻓﺮﻋﻲ ﻭﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ‬
‫ﺗﺤﺬﻳﺮ‬
‫ﻷﻏﺮﺍﺽ ﺍﻟﺘﺮﻛﻴﺐ‪ ،‬ﺗﺄﻛﺪ ﻣﻦ ﺍﺳﺘﻌﻤﺎﻝ ﺍﻷﺟﺰﺍء ﺍﻟﻤﻮﺭﺩﺓ ﻣﻦ ﻗﺒﻞ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺃﻭ ﺍﻷﺟﺰﺍء ﺍﻟﻤﺤﺪﺩﺓ ﺍﻷﺧﺮﻯ‪ .‬ﻳﻤﻜﻦ ﺃﻥ ﻳﺘﺴﺒﺐ‬
‫ﺍﺳﺘﻌﻤﺎﻝ ﺃﺟﺰﺍء ﻏﻴﺮ ﻣﺤﺪﺩﺓ ﻓﻲ ﺣﻮﺍﺩﺙ ﺧﻄﻴﺮﺓ ﻣﺜﻞ ﺳﻘﻮﻁ ﺍﻟﻮﺣﺪﺓ‪ ،‬ﺃﻭ ﺗﺴﺮﺏ ﺍﻟﻤﺎء‪ ،‬ﺃﻭ ﺻﺪﻣﺎﺕ ﻛﻬﺮﺑﺎﺋﻴﺔ‪ ،‬ﺃﻭ ﺣﺮﻳﻖ‪.‬‬
‫ﻗﻄﻊ ﺍﻟﺘﺮﻛﻴﺐ ﺍﻟﺘﺎﻟﻴﺔ ﻣﺰﻭﺩﺓ ﺃﺳﺎﺳﺎ ﻣﻊ ﺍﻟﺠﻬﺎﺯ‪ .‬ﻳﺮﺟﻰ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ ﺣﺴﺐ ﺍﻟﺤﺎﺟﺔ‪.‬‬
‫ﺍﺣﺘﻔﻆ ﺑﻬﺬﺍ ﺍﻟﺪﻟﻴﻞ ﻓﻲ ﻣﻜﺎﻥ ﺁﻣﻦ ﻭﻻ ﺗﺘﺠﺎﻫﻞ ﺃﻱ ﻣﻠﺤﻘﺎﺕ ﺃﺧﺮﻯ ﺣﺘﻰ ﺍﻻﻧﺘﻬﺎء ﻣﻦ ﺃﻋﻤﺎﻝ ﺍﻟﺘﺮﻛﻴﺐ‪.‬‬
‫ﺍﻻﺳﻢ ﻭﺍﻟﺸﻜﻞ‬
‫ﺍﻟﻜﻤﻴﺔ‬
‫ﺃﻧﺒﻮﺏ ﺍﻟﺘﺼﺮﻳﻒ‬
‫‪١‬‬
‫ﺇﺫﺍ ﻛﺎﻥ ﻣﻦ ﺍﻟﻤﺤﺘﻤﻞ ﻭﺟﻮﺩ ﺃﻃﻔﺎﻝ ﺩﻭﻥ ﺳﻦ ﺍﻟﻌﺎﺷﺮﺓ ﺑﺎﻟﻘﺮﺏ ﻣﻦ ﺍﻟﻮﺣﺪﺓ‪ ،‬ﺍﺗﺨﺬ ﺍﻟﺘﺪﺍﺑﻴﺮ ﺍﻟﻮﻗﺎﺋﻴﺔ ﻟﻤﻨﻊ ﺍﻷﻃﻔﺎﻝ ﻣﻦ ﺍﻟﻮﺻﻮﻝ ﺇﻟﻰ‬
‫ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫ﺃﺑﻘﻲ ﻃﻮﻝ ﺃﻧﺎﺑﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﺍﻟﻨﻄﺎﻕ ﺍﻟﻤﺴﻤﻮﺡ ﺑﻪ‪.‬‬
‫ﻭﺻﻒ‬
‫ﺑﺎﻟﻨﺴﺒﺔ ﻷﻋﻤﺎﻝ ﺗﺮﻛﻴﺐ ﺃﻧﺎﺑﻴﺐ ﺍﻟﺘﺼﺮﻳﻒ‬
‫)ﻗﺪ ﻻ ﻳﻜﻮﻥ ﻣﺮﻓﻘﺎً‪ ،‬ﺗﺒﻌﺎً ﻟﻠﻄﺮﺍﺯ‪(.‬‬
‫ﺿﻊ ﻓﻲ ﺍﻻﻋﺘﺒﺎﺭ ﻃﺮﻳﻖ ﺍﻟﻨﻘﻞ‪ ،‬ﻭﻣﺴﺎﺣﺔ ﺍﻟﺘﺮﻛﻴﺐ‪ ،‬ﻭﻣﺴﺎﺣﺔ ﺍﻟﺼﻴﺎﻧﺔ‪ ،‬ﻭﺇﻣﻜﺎﻧﻴﺔ ﺍﻟﻮﺻﻮﻝ‪ ،‬ﻭﺭﻛﺐ ﺍﻟﻮﺣﺪﺓ ﻓﻲ ﻣﻜﺎﻥ ﺑﻪ ﻣﺴﺎﺣﺔ‬
‫ﻛﺎﻓﻴﺔ ﻷﻧﺎﺑﻴﺐ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫ﻷﻏﺮﺍﺽ ﺍﻟﺼﻴﺎﻧﺔ‪ ،‬ﻻ ﺗﻘﻢ ﺑﺪﻓﻦ ﺍﻷﻧﺎﺑﻴﺐ‪.‬‬
‫)‪(١‬‬
‫)‪(٢‬‬
‫)‪(٣‬‬
‫ﻏﻄﺎء ﺍﻟﺘﺼﺮﻳﻒ‬
‫‪٢‬‬
‫)‪(٤‬‬
‫)‪(٥‬‬
‫)‪(٦‬‬
‫)‪(٧‬‬
‫)‪(٨‬‬
‫)‪(٩‬‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺑﻤﻜﺎﻥ ﻳﺘﺤﻤﻞ ﻭﺯﻥ ﺍﻟﻮﺣﺪﺓ ﻭﺍﻻﻫﺘﺰﺍﺯﺍﺕ ﻭﻳﻤﻜﻦ ﺃﻥ ﻳﺘﻢ ﻓﻴﻪ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺑﺸﻜﻞ ﺃﻓﻘﻲ‪.‬‬
‫ﻗﻢ ﺑﺘﺮﻙ ﺍﻟﻤﺴﺎﻓﺎﺕ ﺍﻟﻤﺸﺎﺭ ﺇﻟﻴﻪ ﻟﻀﻤﺎﻥ ﺟﻮﺩﺓ ﺳﺮﻳﺎﻥ ﺍﻟﻬﻮﺍء‪.‬‬
‫ﺇﻥ ﺃﻣﻜﻦ‪ ،‬ﻻ ﺗﺮﻛﺐ ﺍﻟﻮﺣﺪﺓ ﻓﻲ ﻣﻜﺎﻥ ﻳﻜﻮﻥ ﻣﻌﺮﺽ ﻟﻀﻮء ﺍﻟﺸﻤﺲ ﺍﻟﻤﺒﺎﺷﺮ‪.‬‬
‫)ﺍﺫﺍ ﺍﺳﺘﺪﻋﺖ ﺍﻟﻀﺮﻭﺭﺓ‪ ،‬ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺳﺘﺎﺭﺓ ﺃﻭ ﺣﺠﺎﺏ ﺑﺤﻴﺚ ﻻ ﻳﻌﻮﻕ ﺗﺪﻓﻖ ﺍﻟﻬﻮﺍء‪(.‬‬
‫ﻻ ﺗﺮﻛﺐ ﺍﻟﻮﺣﺪﺓ ﻗﺮﺏ ﻣﺼﺪﺭ ﺣﺮﺍﺭﺓ ﺃﻭ ﺑﺨﺎﺭ ﺃﻭ ﻏﺎﺯ ﻗﺎﺑﻞ ﻟﻼﺷﺘﻌﺎﻝ‪.‬‬
‫ﺍﺛﻨﺎء ﺗﺸﻐﻴﻞ ﺍﻟﺘﺪﻓﺌﺔ‪ ،‬ﻳﺘﺪﻓﻖ ﻣﺎء ﺍﻟﺘﺼﺮﻳﻒ ﻣﻦ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪.‬‬
‫ﻟﺬﺍ ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﻣﻜﺎﻥ ﻻ ﻳﺸﻜﻞ ﻋﺎﺋﻘﺎً ﻟﺘﺪﻓﻖ ﻣﺎء ﺍﻟﺘﺼﺮﻳﻒ‪) .‬ﻃﺮﺍﺯ ﺍﻟﺪﻭﺭﺓ ﺍﻟﻌﻜﺴﻴﺔ ﻓﻘﻂ(‬
‫ﻻ ﺗﺮﻛﺐ ﺍﻟﻮﺣﺪﺓ ﻓﻲ ﻣﻜﺎﻥ ﺗﺘﻌﺮﺽ ﻓﻴﻪ ﻟﻬﺒﻮﺏ ﺭﻳﺎﺡ ﻗﻮﻳﺔ ﺃﻭ ﻏﺒﺎﺭ ﺷﺪﻳﺪ‪.‬‬
‫ﻻ ﺗﺮﻛﺐ ﺍﻟﻮﺣﺪﺓ ﻓﻲ ﻣﻜﺎﻥ ﻣﺮﻭﺭ ﺍﻟﻨﺎﺱ‪.‬‬
‫ﺭﻛﺐ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻓﻲ ﻣﻜﺎﻥ ﺑﺤﻴﺚ ﻻ ﻳﺼﻴﺒﻬﺎ ﺍﻷﻭﺳﺎﺥ ﺃﻭ ﺍﻟﺒﻠﻞ ﻣﻦ ﻣﺎء ﺍﻟﻤﻄﺮ ﺑﻘﺪﺭ ﺍﻻﻣﻜﺎﻥ‪.‬‬
‫ﺭﻛﺐ ﺍﻟﻮﺣﺪﺓ ﺑﺤﻴﺚ ﻳﺴﻬﻞ ﻋﻤﻞ ﺍﻟﺘﻮﺻﻴﻼﺕ ﻣﻊ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‪.‬‬
‫‪Ar-٢‬‬
‫‪29/3/2559 8:43:33‬‬
‫‪9381069118_IM_AR.indd 2‬‬
‫ﻣﻜﻴﻒ ﻫﻮﺍء‬
‫ﻻ ﺗﻘﻢ ﺑﺘﻌﺪﻳﻞ ﺳﻠﻚ ﺍﻟﻜﻬﺮﺑﺎء‪ ،‬ﺃﻭ ﺍﺳﺘﺨﺪﻡ ﺳﻠﻚ ﺍﻟﺘﻤﺪﻳﺪ‪ ،‬ﺃﻭ ﺃﺳﻼﻙ ﻓﺮﻋﻴﺔ‪ .‬ﻳﻤﻜﻦ ﺃﻥ ﻳﺘﺴﺒﺐ ﺍﻻﺳﺘﺨﺪﺍﻡ ﻏﻴﺮ ﺍﻟﻤﻨﺎﺳﺐ ﻓﻲ ﺻﺪﻣﺔ‬
‫ﻛﻬﺮﺑﺎﺋﻴﺔ ﺃﻭ ﻧﺸﻮﺏ ﺣﺮﻳﻖ ﻋﻦ ﻃﺮﻳﻖ ﺿﻌﻒ ﺍﻟﺘﻮﺻﻴﻞ ﺃﻭ ﺍﻟﺘﺮﻛﻴﺐ ﻏﻴﺮ ﺍﻟﻤﻨﺎﺳﺐ ﺃﻭ ﺯﻳﺎﺩﺓ ﺍﻟﺘﻴﺎﺭ‪.‬‬
‫ﺩﻟﻴﻞ ﺗﻌﻠﻴﻤﺎﺕ ﺍﻟﺘﺮﻛﻴﺐ‬
‫‪PART No. 9381069118‬‬
‫ﻻ ﺗﻘﻢ ﺑﺘﻨﻈﻴﻒ ﺍﻟﻬﻮﺍء ﺑﺎﺳﺘﻌﻤﺎﻝ ﻣﺎﺩﺓ ﻣﺒﺮﺩﺓ ﺑﻞ ﻗﻢ ﺑﺎﺳﺘﻌﻤﺎﻝ ﻣﻀﺨﺔ ﺍﻟﻬﻮﺍء ﻟﺘﻨﻔﻴﺬ ﺿﺦ ﺍﻟﻬﻮﺍء‪.‬‬
‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‬
‫ﻻ ﻳﻮﺟﺪ ﺳﺎﺋﻞ ﺗﺒﺮﻳﺪ ﺇﺿﺎﻓﻲ ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻹﺧﺮﺍﺝ ﺍﻟﻬﻮﺍء‪.‬‬
‫ﺍﻟﻤﺤﺘﻮﻳﺎﺕ‬
‫ﺃﻋﻠﻢ ﺃﻥ ﺍﺳﺘﺨﺪﺍﻡ ﻣﻀﺨﺔ ﺍﻟﻬﻮﺍء ﻣﻊ ﻣﻮﺍﺩ ﻣﺒﺮﺩﺓ ﺃﺧﺮﻯ ﻗﺪ ﻳﺘﺴﺒﺐ ﻓﻲ ﺗﺤﻄﻴﻢ ﻣﻀﺨﺔ ﺍﻟﻬﻮﺍء ﺃﻭ ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫‪.١‬‬
‫ﺍﺣﺘﻴﺎﻃﺎﺕ ﺍﻻﻣﺎﻥ‪١ ..................................................................................................................‬‬
‫ﻗﻢ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﺸﻌﺐ ﻋﺪﺍﺩﺍﺕ ﻧﻈﻴﻒ ﻭﻣﻀﺨﺔ ﺗﻔﺮﻳﻎ ﻭﺧﺮﻃﻮﻡ ﺷﺤﻦ ﻝ ‪ R410A‬ﻓﻘﻂ‪.‬‬
‫‪.٢‬‬
‫ﺣﻮﻝ ﻫﺬﺍ ﺍﻟﻤﻨﺘﺞ‪١ ...................................................................................................................‬‬
‫‪ ١ ٢‬ﺍﺣﺘﻴﺎﻃﺎﺕ ﻻﺳﺘﺨﺪﺍﻡ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪١ ...........................................................................R410A‬‬
‫‪ ٢ ٢‬ﺃﺩﻭﺍﺕ ﺧﺎﺻﺔ ﻟﺴﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪٢ .................................................................................R410A‬‬
‫‪ ٣ ٢‬ﻣﻠﺤﻘﺎﺕ‪٢ ...................................................................................................................‬‬
‫ﻻ ﺗﻘﻢ ﺑﺘﻌﺪﻳﻞ ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ‪ ،‬ﻣﻘﻞ ﻋﻤﻞ ﻓﺘﺤﺔ ﻓﻲ ﺍﻟﺤﺎﻭﻳﺔ‪.‬‬
‫‪.٣‬‬
‫ﺃﻋﻤﺎﻝ ﺍﻟﺘﺮﻛﻴﺐ‪٢ ....................................................................................................................‬‬
‫‪ ١ ٣‬ﺍﺧﺘﻴﺎﺭ ﻣﻮﻗﻊ ﺍﻟﺘﺜﺒﻴﺖ‪٢ .....................................................................................................‬‬
‫‪ ٢ ٣‬ﺃﺑﻌﺎﺩ ﺍﻟﺘﺮﻛﻴﺐ‪٣ ............................................................................................................‬‬
‫‪ ٣ ٣‬ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ‪٣ ...........................................................................................................‬‬
‫‪ ٤ ٣‬ﺗﺮﻛﻴﺐ ﺍﻟﺘﺼﺮﻳﻒ‪٤ ........................................................................................................‬‬
‫‪ ٥ ٣‬ﻗﻢ ﺑﺘﺄﻣﻴﻦ ﺍﻟﻮﺣﺪﺓ‪٤ .........................................................................................................‬‬
‫‪.٤‬‬
‫ﺗﺮﻛﻴﺐ ﺍﻷﻧﺎﺑﻴﺐ ‪٤ ...................................................................................................................‬‬
‫‪ ١ ٤‬ﺍﺧﺘﻴﺎﺭ ﻣﺎﺩﺓ ﺍﻷﻧﺎﺑﻴﺐ‪٤ .....................................................................................................‬‬
‫‪ ٢ ٤‬ﻣﺘﻄﻠﺒﺎﺕ ﺍﻷﻧﺎﺑﻴﺐ‪٥ ........................................................................................................‬‬
‫‪ ٣ ٤‬ﺍﻟﻠﺤﺎﻡ ﺑﺎﻟﻨﺤﺎﺱ ﺍﻷﺻﻔﺮ ‪٥ .................................................................................................‬‬
‫‪ ٤ ٤‬ﺗﻮﺻﻴﻞ ﺍﻷﻧﺎﺑﻴﺐ ‪٥ .........................................................................................................‬‬
‫‪ ٥ ٤‬ﺍﺧﺘﺒﺎﺭ ﺇﺣﻜﺎﻡ ﺍﻟﺴﺪ ‪٦ .......................................................................................................‬‬
‫‪ ٦ ٤‬ﻋﻤﻠﻴﺔ ﺗﻔﺮﻳﻎ ﺍﻟﻬﻮﺍء‪٦ ......................................................................................................‬‬
‫‪ ٧ ٤‬ﺍﻟﺸﺤﻦ ﺍﻹﺿﺎﻓﻲ ‪٦ .........................................................................................................‬‬
‫‪ ٨ ٤‬ﻓﺤﺺ ﺗﺴﺮﺏ ﺍﻟﻐﺎﺯ ‪٧ .....................................................................................................‬‬
‫‪.٥‬‬
‫ﺗﺮﻛﻴﺐ ﺍﻷﺳﻼﻙ ﺍﻟﻜﻬﺮﺑﻴﺔ‪٧ .........................................................................................................‬‬
‫‪ ١ ٥‬ﻣﻼﺣﻈﺎﺕ ﺧﺎﺻﺔ ﺑﺘﺮﻛﻴﺐ ﺍﻷﺳﻼﻙ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‪٧ .........................................................................‬‬
‫‪ ٢ ٥‬ﺍﺧﺘﻴﺎﺭ ﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ ﻭﺳﻠﻚ ‪٧ ...............................................................................................‬‬
‫‪ ٣ ٥‬ﻃﺮﻳﻘﺔ ﺗﻤﺪﻳﺪ ﺍﻷﺳﻼﻙ ‪٨ ...................................................................................................‬‬
‫‪.٦‬‬
‫ﺍﻟﺘﺸﻐﻴﻞ ﺍﻹﺧﺘﺒﺎﺭﻱ‪٨ ................................................................................................................‬‬
‫‪.٧‬‬
‫ﻗﺎﺋﻤﺔ ﺍﻟﻔﺤﺺ‪٨ ......................................................................................................................‬‬
‫‪.٨‬‬
‫ﺷﺎﺷﺔ ‪٩ ...................................................................................................................... LED‬‬
‫‪.٩‬‬
‫ﻋﻤﻠﻴﺔ ﺍﻟﻀﺦ ﺍﻟﺴﻔﻠﻲ ‪٩ ..............................................................................................................‬‬
‫ﻣﻼﺣﻈﺔ‪ :‬ﻳﻮﺿﺢ ﻫﺬﺍ ﺍﻟﺪﻟﻴﻞ ﻛﻴﻔﻴﺔ ﺗﺮﻛﻴﺐ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء ﺍﻟﻤﻮﺿﺢ ﺃﻋﻼﻩ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻢ ﺍﻟﺘﻌﺎﻣﻞ ﻣﻊ ﺍﻟﻮﺣﺪﺓ ﻭﺗﺮﻛﻴﺒﻬﺎ ﺑﻮﺍﺳﻄﺔ ﻓﻨﻲ‬
‫ﺍﻟﺘﺮﻛﻴﺐ ﺍﻟﻤﺤﺘﺮﻑ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ ﻫﺬﺍ ﺍﻟﺪﻟﻴﻞ‪.‬‬
‫ﺃﺛﻨﺎء ﻋﻤﻠﻴﺔ ﺍﻟﻀﺦ ﺍﻟﺴﻔﻠﻲ‪ ،‬ﺗﺄﻛﺪ ﻣﻦ ﺇﻳﻘﺎﻑ ﺗﺸﻐﻴﻞ ﺍﻟﻀﺎﻏﻂ ﻗﺒﻞ ﺇﺯﺍﻟﺔ ﺃﻧﺎﺑﻴﺐ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫ﻻ ﺗﻨﺰﻉ ﺃﻧﺎﺑﻴﺐ ﺍﻟﺘﻮﺻﻴﻞ ﺃﺛﻨﺎء ﻋﻤﻞ ﺍﻟﻀﺎﻏﻂ ﻭﻓﺘﺢ ﺍﻟﺼﻤﺎﻡ ﺍﻟﺜﻼﺛﻲ‪ .‬ﻗﺪ ﻳﺘﺴﺒﺐ ﻫﺬﺍ ﻓﻲ ﺣﺪﻭﺙ ﺿﻐﻂ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﻓﻲ ﺩﻭﺭﺓ‬
‫ﺍﻟﺘﺒﺮﻳﺪ ﺍﻷﻣﺮ ﺍﻟﺬﻱ ﻳﺆﺩﻱ ﺑﺪﻭﺭﻩ ﺇﻟﻰ ﺣﺪﻭﺙ ﺍﻧﻔﺠﺎﺭ ﺃﻭ ﺇﺻﺎﺑﺎﺕ‪.‬‬
‫ﺗﻨﺒﻴﻪ‬
‫ﻳﺸﻴﺮ ﺇﻟﻰ ﻣﻮﻗﻒ ﺧﻄﺮ ﻣﺤﺘﻤﻞ ﻭﺍﻟﺬﻱ ﻗﺪ ﻳﺆﺩﻱ ﺇﻟﻰ ﺇﺻﺎﺑﺔ ﺧﻔﻴﻔﺔ ﺃﻭ ﺗﻠﻒ ﺍﻟﻤﻤﺘﻠﻜﺎﺕ‪.‬‬
‫ﻳﺠﺐ ﺗﺮﻛﻴﺐ ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ ﺑﻮﺍﺳﻄﺔ ﺃﻓﺮﺍﺩ ﻣﺆﻫﻠﻴﻦ ﻟﺪﻳﻬﻢ ﺷﻬﺎﺩﺓ ﻗﺪﺭﺓ ﻋﻠﻰ ﺍﻟﺘﻌﺎﻣﻞ ﻣﻊ ﺳﻮﺍﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ .‬ﺍﺭﺟﻊ ﺇﻟﻰ ﺍﻟﻠﻮﺍﺋﺢ ﻭ ﺍﻟﻘﻮﺍﻧﻴﻦ‬
‫ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻓﻲ ﻣﻜﺎﻥ ﺍﻟﺘﺮﻛﻴﺐ‪.‬‬
‫ﻗﻢ ﺑﺘﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﻣﻦ ﺧﻼﻝ ﺇﺗﺒﺎﻉ ﺍﻟﻠﻮﺍﺋﺢ ﻭﺍﻟﻘﻮﺍﻧﻴﻦ ﺍﻟﻤﺤﻠﻴﺔ ﺍﻟﺴﺎﺭﻳﺔ ﻓﻲ ﻣﻜﺎﻥ ﺍﻟﺘﺮﻛﻴﺐ ﻭﺍﻹﺭﺷﺎﺩﺍﺕ ﺍﻟﻤﺰﻭﺩﺓ ﺑﻮﺍﺳﻄﺔ ﺍﻟﺸﺮﻛﺔ‬
‫ﺍﻟﻤﺼﻨﻌﺔ‪.‬‬
‫ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ ﻫﻲ ﺟﺰء ﻣﻦ ﻣﺠﻤﻮﻋﺔ ﺗﺸﻜﻞ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء‪ .‬ﻻ ﻳﺠﺐ ﺗﺮﻛﻴﺐ ﺍﻟﻮﺣﺪﺓ ﺑﺸﻜﻞ ﻣﻨﻔﺼﻞ ﺃﻭ ﻣﻊ ﺟﻬﺎﺯ ﻏﻴﺮ ﻣﻌﺘﻤﺪ ﻣﻦ‬
‫ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ‪.‬‬
‫ﻋﻨﺪ ﺗﺮﻛﻴﺐ ﺃﻧﺎﺑﻴﺐ ﺃﻗﺼﺮ ﻣﻦ ‪ ٣‬ﻡ‪ ،‬ﻓﺴﻴﺘﻢ ﺍﻧﺘﻘﺎﻝ ﺻﻮﺕ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﺇﻟﻰ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ‪ ،‬ﻭﺍﻟﺘﻲ ﺳﺘﺘﺴﺒﺐ ﻓﻲ ﺻﺪﻭﺭ‬
‫ﺻﻮﺕ ﺗﺸﻐﻴﻞ ﻣﺮﺗﻔﻊ ﺃﻭ ﺑﻌﺾ ﺍﻷﺻﻮﺍﺕ ﻏﻴﺮ ﺍﻟﻤﻌﺘﺎﺩﺓ‪.‬‬
‫ﺍﺳﺘﺨﺪﻡ ﺩﺍﺋﻤﺎ ﺧﻂ ﺇﻣﺪﺍﺩ ﺑﺎﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﻣﻨﻔﺼﻞ ﻣﺤﻤﻲ ﺑﻮﺍﺳﻄﺔ ﻗﻮﺍﻃﻊ ﺩﻭﺍﺋﺮ ﺗﻌﻤﻞ ﻋﻠﻰ ﺟﻤﻴﻊ ﺍﻷﺳﻼﻙ ﻣﻊ ﻭﺻﻮﻝ ﺍﻟﻤﺴﺎﻓﺔ‬
‫ﺑﻴﻦ ﻧﻘﺎﻁ ﺍﻻﺗﺼﺎﻝ ﺇﻟﻰ ‪ ٣‬ﻣﻢ ﻟﻬﺬﻩ ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫ﻟﺤﻤﺎﻳﺔ ﺍﻷﻓﺮﺍﺩ‪ ،‬ﻗﻢ ﺑﺘﺄﺭﻳﺾ ﺍﻟﻮﺣﺪﺓ ﺑﺸﻜﻞ ﺻﺤﻴﺢ ﻭﺍﺳﺘﺨﺪﺍﻡ ﻛﺎﺑﻞ ﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﺮﻓﻖ ﻣﻊ ﻗﺎﻃﻊ ﺩﺍﺋﺮﺓ ﺍﻟﺘﺴﺮﺏ ﺍﻷﺭﺿﻲ )‪.(ELCB‬‬
‫ﺍﻟﻮﺣﺪﺍﺕ ﻟﻴﺴﺖ ﻣﻘﺎﻭﻣﺔ ﻟﻼﻧﻔﺠﺎﺭ‪ ،‬ﻭﺑﺎﻟﺘﺎﻟﻲ ﻻ ﻳﺠﺐ ﺗﺮﻛﻴﺒﻬﺎ ﻓﻲ ﻣﻨﺎﺥ ﻗﺎﺑﻞ ﻟﻼﻧﻔﺠﺎﺭ‪.‬‬
‫ﻻ ﺗﺸﺘﻤﻞ ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ ﻋﻠﻰ ﻗﻄﻊ ﻗﺎﺑﻠﺔ ﻟﻠﺼﻴﺎﻧﺔ ﺑﻮﺍﺳﻄﺔ ﺍﻟﻤﺴﺘﺨﺪﻡ‪ .‬ﻗﻢ ﺩﺍﺋﻤًﺎ ﺑﺎﺳﺘﺸﺎﺭﺓ ﻓﻨﻲ ﺧﺪﻣﺔ ﻣﺤﺘﺮﻑ ﻓﻲ ﻋﻤﻠﻴﺎﺕ ﺍﻹﺻﻼﺡ‪.‬‬
‫ﻋﻨﺪ ﻧﻘﻞ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء ﺃﻭ ﺗﻐﻴﻴﺮ ﻣﻮﺿﻌﻪ‪ ،‬ﻗﻢ ﺑﺎﺳﺘﺸﺎﺭﺓ ﻓﻨﻴﻲ ﺧﺪﻣﺔ ﻣﺤﺘﺮﻓﻴﻦ ﻟﻔﺼﻞ ﺍﻟﻮﺣﺪﺓ ﻭﺇﻋﺎﺩﺓ ﺗﺮﻛﻴﺒﻬﺎ‪.‬‬
‫ﻳﺘﻮﺟﺐ ﺃﻥ ﺗﺘﻢ ﻣﺮﺍﻗﺒﺔ ﺍﻷﻃﻔﺎﻝ ﻟﻀﻤﺎﻥ ﻋﺪﻡ ﻟﻌﺒﻬﻢ ﺑﺎﻟﺠﻬﺎﺯ‪.‬‬
‫ﻫﺬﺍ ﺍﻟﺠﻬﺎﺯ ﻏﻴﺮ ﻣﺨﺼﺺ ﻟﻼﺳﺘﺨﺪﺍﻡ ﻣﻦ ﺟﺎﻧﺐ ﺍﻷﺷﺨﺎﺹ ﺍﻟﺬﻳﻦ ﻳﻌﺎﻧﻮﻥ ﻣﻦ ﻧﻘﺺ ﻓﻲ ﺍﻟﻘﺪﺭﺍﺕ ﺍﻟﺒﺪﻧﻴﺔ ﺃﻭ ﺍﻟﺸﻌﻮﺭﻳﺔ ﺃﻭ ﺍﻟﻌﻘﻠﻴﺔ‬
‫)ﺑﻤﺎ ﻓﻴﻬﻢ ﺍﻷﻃﻔﺎﻝ( ﺃﻭ ﻧﻘﺺ ﻓﻲ ﺍﻟﺨﺒﺮﺓ ﻭﺍﻟﻤﻌﺮﻓﺔ‪ ،‬ﻣﺎ ﻟﻢ ﻳﺘﻢ ﺍﻹﺷﺮﺍﻑ ﻋﻠﻴﻬﻢ ﺃﻭ ﺇﻋﻄﺎﺋﻬﻢ ﺍﻟﺘﻌﻠﻴﻤﺎﺕ ﺍﻟﻤﺘﻌﻠﻘﺔ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺍﻟﺠﻬﺎﺯ ﻣﻦ‬
‫ﺟﺎﻧﺐ ﺷﺨﺺ ﻣﺴﺆﻭﻝ ﻋﻦ ﺳﻼﻣﺘﻬﻢ‪ .‬ﻳﺘﻮﺟﺐ ﺃﻥ ﺗﺘﻢ ﻣﺮﺍﻗﺒﺔ ﺍﻷﻃﻔﺎﻝ ﻟﻀﻤﺎﻥ ﻋﺪﻡ ﻟﻌﺒﻬﻢ ﺑﺎﻟﺠﻬﺎﺯ‪.‬‬
‫ﻻ ﺗﻘﻢ ﺑﻠﻤﺲ ﺍﻷﺟﻨﺤﺔ ﺍﻷﻟﻮﻣﻨﻴﻮﻡ ﻟﻠﻤﺒﺎﺩﻝ ﺍﻟﺤﺮﺍﺭﻱ ﺍﻟﻤﺪﻣﺠﺔ ﻓﻲ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺃﻭ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻟﺘﺠﻨﺐ ﺍﻹﺻﺎﺑﺔ ﺍﻟﺸﺨﺼﻴﺔ‬
‫ﻋﻨﺪ ﺗﺮﻛﻴﺐ ﺃﻭ ﺻﻴﺎﻧﺔ ﺍﻟﻮﺣﺪﺓ‪.‬‬
‫ﻻ ﺗﻘﻮﻡ ﺑﻮﺿﻊ ﺃﻳﺔ ﻣﻨﺘﺠﺎﺕ ﻛﻬﺮﺑﺎﺋﻴﺔ ﺃﺧﺮﻯ ﺃﻭ ﻣﺘﻌﻠﻘﺎﺕ ﻣﻨﺰﻟﻴﺔ ﺗﺤﺖ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﺃﻭ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‪ .‬ﻗﺪ ﻳﺘﺴﺒﺐ ﺍﻟﺘﻘﻄﻴﺮ‬
‫ﺍﻟﻨﺎﺗﺞ ﻋﻦ ﺍﻟﺘﻜﺜﻴﻒ ﻣﻦ ﺍﻟﻤﻨﺘﺞ ﺇﻟﻰ ﺗﻌﺮﻳﻀﻬﺎ ﻟﻠﺒﻠﻞ ﻭﻗﺪ ﻳﺆﺩﻱ ﺇﻟﻰ ﺇﺗﻼﻑ ﺃﻭ ﺗﻌﻄﻞ ﺍﻟﻤﻠﻜﻴﺔ‪.‬‬
‫‪ .١‬ﺍﺣﺘﻴﺎﻃﺎﺕ ﺍﻻﻣﺎﻥ‬
‫• ﺗﺄﻛﺪ ﻣﻦ ﻗﺮﺍءﺓ ﻫﺬﺍ ﺍﻟﺪﻟﻴﻞ ﺑﺎﻟﻜﺎﻣﻞ ﻗﺒﻞ ﺍﻟﺘﺮﻛﻴﺐ‪.‬‬
‫• ﺗﺤﺘﻮﻱ ﺍﻟﺘﺤﺬﻳﺮﺍﺕ ﻭﺍﻻﺣﺘﻴﺎﻃﺎﺕ ﺍﻟﻮﺍﺭﺩﺓ ﻓﻲ ﻫﺬﺍ ﺍﻟﺪﻟﻴﻞ ﻋﻠﻰ ﻣﻌﻠﻮﻣﺎﺕ ﻣﻬﻤﺔ ﻣﺘﻌﻠﻘﺔ ﺑﺴﻼﻣﺘﻚ‪ .‬ﺗﺄﻛﺪ ﻣﻦ ﻣﺮﺍﻋﺎﺗﻬﺎ‪.‬‬
‫• ﻗﻢ ﺑﺘﺴﻠﻴﻢ ﻫﺬﺍ ﺍﻟﺪﻟﻴﻞ‪ ،‬ﺟﻨﺒﺎ ﺇﻟﻰ ﺟﻨﺐ ﻣﻊ ﺩﻟﻴﻞ ﺍﻟﺘﺸﻐﻴﻞ ﺇﻟﻰ ﺍﻟﻌﻤﻴﻞ‪ .‬ﺃﻃﻠﺐ ﻣﻦ ﺍﻟﻌﻤﻴﻞ ﺍﻻﺣﺘﻔﺎﻅ ﺑﻬﻤﺎ ﻓﻲ ﻣﺘﻨﺎﻭﻝ ﺍﻟﻴﺪ ﻟﻼﺳﺘﺨﺪﺍﻡ‬
‫ﻓﻲ ﺍﻟﻤﺴﺘﻘﺒﻞ‪ ،‬ﻣﺜﻞ ﻧﻘﻞ ﺍﻟﻮﺣﺪﺓ ﺇﻟﻰ ﻣﻜﺎﻥ ﺁﺧﺮ ﺃﻭ ﺇﺻﻼﺡ ﺍﻟﻤﻨﺘﺞ‪.‬‬
‫ﺗﺤﺬﻳﺮ‬
‫‪ .٢‬ﺣﻮﻝ ﻫﺬﺍ ﺍﻟﻤﻨﺘﺞ‬
‫‪ ١ ٢‬ﺍﺣﺘﻴﺎﻃﺎﺕ ﻻﺳﺘﺨﺪﺍﻡ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ‪R410A‬‬
‫ﻳﺸﻴﺮ ﺇﻟﻰ ﻣﻮﻗﻒ ﺧﻄﺮ ﻣﺤﺘﻤﻞ ﻭﺍﻟﺬﻱ‪ ،‬ﺇﺫﺍ ﻟﻢ ﻳﺘﻢ ﺗﻔﺎﺩﻳﻪ‪ ،‬ﻗﺪ ﻳﺆﺩﻱ ﺇﻟﻰ ﺍﻟﻮﻓﺎﺓ ﺃﻭ ﺣﺪﻭﺙ ﺇﺻﺎﺑﺔ‬
‫ﺧﻄﻴﺮﺓ‪.‬‬
‫ً‬
‫ﻟﺘﻔﺎﺩﻱ ﺍﻟﺘﻌﺮﺽ ﺇﻟﻰ ﺻﺪﻣﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ‪ ،‬ﻻ ﺗﻘﻢ‬
‫ﻣﻄﻠﻘﺎ ﺑﻠﻤﺲ ﺍﻟﻤﻜﻮﻧﺎﺕ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﺑﻌﺪ ﺇﻳﻘﺎﻑ ﺇﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ ﺑﻔﺘﺮﺓ ﻗﺼﻴﺮﺓ‪ .‬ﺑﻌﺪ ﺇﻳﻘﺎﻑ‬
‫ﺍﻟﺘﺸﻐﻴﻞ‪ ،‬ﻗﻢ ﺩﺍﺋﻤًﺎ ﺑﺎﻻﻧﺘﻈﺎﺭ ﻟﻤﺪﺓ ‪ ١٠‬ﺩﻗﺎﺋﻖ ﺃﻭ ﺃﻛﺜﺮ ﻗﺒﻞ ﻟﻤﺲ ﺍﻟﻤﻜﻮﻧﺎﺕ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‪.‬‬
‫ﻳﺠﺐ ﺗﺮﻛﻴﺐ ﻫﺬﺍ ﺍﻟﻤﻨﺘﺞ ﺑﻮﺍﺳﻄﺔ ﻓﻨﻲ ﺧﺪﻣﺔ ﺧﺒﻴﺮ ﺃﻭ ﻓﻨﻲ ﺗﺮﻛﻴﺐ ﻣﻬﻨﻲ ﻓﻘﻂ ﺑﻤﺎ ﻳﺘﻮﺍﻓﻖ ﻣﻊ ﻫﺬﺍ ﺍﻟﺪﻟﻴﻞ‪ .‬ﻗﺪ ﻳﺆﺩﻱ ﺍﻟﺘﺮﻛﻴﺐ‬
‫ﺑﻮﺍﺳﻄﺔ ﺷﺨﺺ ﻏﻴﺮ ﻣﺤﺘﺮﻑ ﺃﻭ ﺍﻟﺘﺮﻛﻴﺐ ﻏﻴﺮ ﺍﻟﺼﺤﻴﺢ ﻟﻠﻤﻨﺘﺞ ﺇﻟﻰ ﺍﻟﺘﻌﺮﺽ ﻟﺤﻮﺍﺩﺙ ﺧﻄﻴﺮﺓ ﻣﺜﻞ ﺍﻹﺻﺎﺑﺔ ﺃﻭ ﺗﺴﺮﺏ ﺍﻟﻤﺎء‬
‫ﺃﻭ ﺣﺪﻭﺙ ﺻﺪﻣﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ ﺃﻭ ﺣﺮﻳﻖ‪ .‬ﺇﺫﺍ ﺗﻢ ﺗﺮﻛﻴﺐ ﺍﻟﻤﻨﺘﺞ ﻭﺗﺠﺎﻫﻞ ﺍﻹﺭﺷﺎﺩﺍﺕ ﺍﻟﻮﺍﺭﺩﺓ ﻓﻲ ﻫﺬﺍ ﺍﻟﺪﻟﻴﻞ‪ ،‬ﻓﺴﻴﺆﺩﻱ ﻫﺬﺍ ﺇﻟﻰ ﺇﻟﻐﺎء‬
‫ﺿﻤﺎﻥ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ‪.‬‬
‫ﻻ ﺗﻌﻤﺪ ﺇﻟﻰ ﺗﻮﺻﻴﻞ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﺇﻻ ﺑﻌﺪ ﺍﻻﻧﺘﻬﺎء ﻣﻦ ﺟﻤﻴﻊ ﺃﻋﻤﺎﻝ ﺍﻟﺘﺮﻛﻴﺐ‪ .‬ﻗﺪ ﻳﺆﺩﻱ ﺗﺸﻐﻴﻞ ﺍﻟﻄﺎﻗﺔ ﻗﺒﻞ ﺍﺳﺘﻜﻤﺎﻝ ﺍﻟﻌﻤﻞ ﺇﻟﻰ‬
‫ﺍﻟﺘﺴﺒﺐ ﻓﻲ ﺣﻮﺍﺩﺙ ﺧﻄﻴﺮﺓ ﻣﺜﻞ ﺻﺪﻣﺔ ﻛﻬﺮﺑﺎﺋﻴﺔ ﺃﻭ ﺣﺮﻳﻖ‪.‬‬
‫ﺇﺫﺍ ﺗﺴﺮﺏ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺃﺛﻨﺎء ﻗﻴﺎﻣﻚ ﺑﺎﻟﻌﻤﻞ‪ ،‬ﻓﻘﻢ ﺑﺘﻬﻮﻳﺔ ﺍﻟﻤﻨﻄﻘﺔ‪ .‬ﺇﺫﺍ ﻛﺎﻥ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻟﺬﻱ ﺗﺴﺮﺏ ﻣﻌﺮﺽ ﻟﺸﻌﻠﺔ ﻟﻬﺐ‪ ،‬ﻓﻘﺪ‬
‫ﻳﺆﺩﻱ ﺇﻟﻰ ﺍﻧﺒﻌﺎﺙ ﻏﺎﺯ ﺳﺎﻡ‪.‬‬
‫ﻳﺠﺐ ﺍﻟﻘﻴﺎﻡ ﺑﺎﻟﺘﺮﻛﻴﺐ ﺑﻤﺎ ﻳﺘﻮﺍﻓﻖ ﻣﻊ ﺍﻟﻘﻮﺍﻧﻴﻦ ﺃﻭ ﺍﻟﻠﻮﺍﺋﺢ ﺃﻭ ﺍﻟﻤﻌﺎﻳﻴﺮ ﺍﻟﺨﺎﺻﺔ ﺑﺘﻮﺻﻴﻞ ﺍﻷﺳﻼﻙ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻭﺍﻟﺠﻬﺎﺯ ﻓﻲ ﻛﻞ ﺩﻭﻟﺔ‬
‫ﺃﻭ ﻣﻮﻗﻊ ﺗﺮﻛﻴﺐ‪.‬‬
‫ﺗﺤﺬﻳﺮ‬
‫ﻻ ﺗﻀﻊ ﺃﻱ ﻣﺎﺩﺓ ﺃﺧﺮﻯ ﻏﻴﺮ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻟﻤﻘﺮﺭ ﻓﻲ ﺩﻭﺭﺓ ﺍﻟﺘﺒﺮﻳﺪ‪ .‬ﺇﺫﺍ ﺩﺧﻞ ﺍﻟﻬﻮﺍء ﺇﻟﻰ ﺩﻭﺭﺓ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺳﻴﺼﺒﺢ ﺍﻟﻀﻐﻂ ﻓﻲ‬
‫ﺩﻭﺭﺓ ﺍﻟﺘﺒﺮﻳﺪ ﻣﺮﺗﻔﻌﺎ ﺑﺸﻜﻞ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﻭ ﻳﺘﺴﺒﺐ ﻓﻲ ﺗﻤﺰﻕ ﺍﻷﻧﺎﺑﻴﺐ‪.‬‬
‫ﺇﺫﺍ ﺣﺪﺙ ﺗﺴﺮﺏ ﻓﻲ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﺗﺄﻛﺪ ﻣﻦ ﺃﻧﻪ ﻻ ﻳﺘﺠﺎﻭﺯ ﺣﺪ ﺍﻟﺘﺮﻛﻴﺰ‪ .‬ﺇﺫﺍ ﺗﺠﺎﻭﺯ ﺗﺴﺮﺏ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺣﺪ ﺍﻟﺘﺮﻛﻴﺰ‪ ،‬ﻳﻤﻜﻦ ﺃﻥ‬
‫ﻳﺆﺩﻱ ﺇﻟﻰ ﻭﻗﻮﻉ ﺣﻮﺍﺩﺙ ﻣﺜﻞ ﺍﻟﻤﻮﺕ ﺑﺴﺒﺐ ﻧﻘﺺ ﺍﻷﻛﺴﺠﻴﻦ‪.‬‬
‫ﻻ ﺗﻠﻤﺲ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻟﺬﻱ ﺗﺴﺮﺏ ﻣﻦ ﺗﻮﺻﻴﻼﺕ ﺃﻧﺒﻮﺏ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺃﻭ ﻣﻨﻄﻘﺔ ﺃﺧﺮﻯ‪ .‬ﻳﻤﻜﻦ ﺃﻥ ﻳﺘﺴﺒﺐ ﻟﻤﺲ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‬
‫ﺑﺸﻜﻞ ﻣﺒﺎﺷﺮ ﻓﻲ ﺗﻘﺮﺡ ﺍﻟﺠﻠﺪ ﻣﻦ ﺷﺪﺓ ﺍﻟﺒﺮﺩ‪.‬‬
‫ﻓﻲ ﺣﺎﻝ ﺣﺪﻭﺙ ﺗﺴﺮﺏ ﻟﺴﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺃﺛﻨﺎء ﺍﻟﺘﺸﻐﻴﻞ‪ ،‬ﺃﺧﻠﻲ ﺍﻟﻤﻜﺎﻥ ﻋﻠﻰ ﺍﻟﻔﻮﺭ ﻭﻗﻢ ﺑﺘﻬﻮﻳﺔ ﺍﻟﻤﻨﻄﻘﺔ ﺟﻴﺪﺍ‪ .‬ﺇﺫﺍ ﺣﺪﺙ ﺗﻼﻣﺲ ﻟﺴﺎﺋﻞ‬
‫ﺍﻟﺘﺒﺮﻳﺪ ﻣﻊ ﺷﻌﻠﺔ ﺳﻴﺘﻢ ﺗﻮﻟﻴﺪ ﻏﺎﺯ ﺳﺎﻡ‪.‬‬
‫ﺧﻄﻮﺍﺕ ﺃﻋﻤﺎﻝ ﺍﻟﺘﺮﻛﻴﺐ ﺍﻷﺳﺎﺳﻴﺔ ﻫﻲ ﻧﻔﺲ ﻧﻤﺎﺫﺝ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻟﺘﻘﻠﻴﺪﻳﺔ‪.‬‬
‫ﻭﻣﻊ ﺫﻟﻚ‪ ،‬ﺃﻋﻂ ﺍﻫﺘﻤﺎﻡ ﻛﺒﻴﺮ ﻟﻠﻨﻘﺎﻁ ﺍﻟﺘﺎﻟﻴﺔ‪:‬‬
‫ﻻ ﺗﻘﻢ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺍﻟﺠﻬﺎﺯ ﺃﺛﻨﺎء ﻭﺟﻮﺩ ﻫﻮﺍء ﺃﻭ ﺃﻱ ﺳﺎﺋﻞ ﺗﺒﺮﻳﺪ ﻏﻴﺮ ﻣﺤﺪﺩ ﺁﺧﺮ ﻓﻲ ﺃﻧﺎﺑﻴﺐ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ .‬ﻗﺪ ﻳﺆﺩﻱ ﺍﻟﻀﻐﻂ ﺍﻟﻤﻔﺮﻁ‬
‫ﺇﻟﻰ ﺣﺪﻭﺙ ﺍﻧﻔﺠﺎﺭ‪.‬‬
‫ﺃﺛﻨﺎء ﻋﻤﻠﻴﺔ ﺍﻟﺘﺮﻛﻴﺐ‪ ،‬ﺍﺣﺮﺹ ﻋﻠﻰ ﺃﻥ ﻳﻜﻮﻥ ﺃﻧﺒﻮﺏ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﻣﺜﺒﺘﺎً ﺑﺈﺣﻜﺎﻡ ﻗﺒﻞ ﺗﺸﻐﻴﻞ ﺍﻟﻀﺎﻏﻂ‪ .‬ﻻ ﺗﻘﻢ ﺑﺘﺸﻐﻴﻞ ﺍﻟﻀﺎﻏﻂ‬
‫ﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﺗﺮﻛﻴﺐ ﺃﻧﺎﺑﻴﺐ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺑﺸﻜﻞ ﺻﺤﻴﺢ ﺃﺛﻨﺎء ﻓﺘﺢ ﺍﻟﺼﻤﺎﻡ ﺛﻼﺛﻲ ﺍﻻﺗﺠﺎﻩ‪ .‬ﻗﺪ ﻳﺘﺴﺒﺐ ﻫﺬﺍ ﻓﻲ ﺣﺪﻭﺙ ﺿﻐﻂ ﻏﻴﺮ‬
‫ﻃﺒﻴﻌﻲ ﻓﻲ ﺩﻭﺭﺓ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻷﻣﺮ ﺍﻟﺬﻱ ﻳﺆﺩﻱ ﺑﺪﻭﺭﻩ ﺇﻟﻰ ﺣﺪﻭﺙ ﺍﻧﻔﺠﺎﺭ ﺃﻭ ﺇﺻﺎﺑﺎﺕ‪.‬‬
‫ﻋﻨﺪ ﺗﺮﻛﻴﺐ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء ﺃﻭ ﺗﻐﻴﻴﺮ ﻣﻮﺿﻌﻪ‪ ،‬ﻓﻼ ﺗﻘﻢ ﺑﺨﻠﻂ ﻏﺎﺯﺍﺕ ﺑﺨﻼﻑ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ ﺍﻟﻤﺤﺪﺩ ‪ R410A‬ﻹﺩﺧﺎﻟﻬﺎ ﺇﻟﻰ ﺩﻭﺭﺓ‬
‫ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪.‬‬
‫ﺇﺫﺍ ﺩﺧﻞ ﺍﻟﻬﻮﺍء ﺃﻭ ﺃﻱ ﻏﺎﺯ ﺁﺧﺮ ﺇﻟﻰ ﺩﻭﺭﺓ ﺳﺎﺋﻞ ﺍﻟﺘﺒﺮﻳﺪ‪ ،‬ﻓﺴﻴﺮﺗﻔﻊ ﺍﻟﻀﻐﻂ ﺩﺍﺧﻞ ﺍﻟﺪﻭﺭﺓ ﺇﻟﻰ ﻗﻴﻤﺔ ﻣﺮﺗﻔﻌﺔ ﺑﺸﻜﻞ ﻏﻴﺮ ﻃﺒﻴﻌﻲ ﻣﻤﺎ‬
‫ﻗﺪ ﻳﺆﺩﻱ ﺇﻟﻰ ﺍﻻﻧﻔﺠﺎﺭ ﺃﻭ ﺍﻹﺻﺎﺑﺔ ﺃﻭ ﻣﺎ ﺷﺎﺑﻪ‪.‬‬
‫ﻟﻀﻤﺎﻥ ﻋﻤﻞ ﻣﻜﻴّﻒ ﺍﻟﻬﻮﺍء ﺑﺸﻜﻞ ﻣﻨﺎﺳﺐ‪ ،‬ﻗﻢ ﺑﺘﺮﻛﻴﺒﻪ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﻤﺒﻴﻦ ﻓﻲ ﻫﺬﺍ ﺍﻟﺪﻟﻴﻞ‪.‬‬
‫ﻟﺘﻮﺻﻴﻞ ﺍﻟﻮﺣﺪﺓ ﺍﻟﺪﺍﺧﻠﻴﺔ ﻭﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ ﻗﻢ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺃﻧﺎﺑﻴﺐ ﻭﻛﺎﺑﻼﺕ ﻣﻜﻴﻒ ﺍﻟﻬﻮﺍء ﺍﻟﻤﺘﺎﺣﺔ ﻣﺤﻠﻴًﺎ ﻛﻘﻄﻊ ﻏﻴﺎﺭ ﻗﻴﺎﺳﻴﺔ‪.‬‬
‫ﻳﻮﺿﺢ ﻫﺬﺍ ﺍﻟﺪﻟﻴﻞ ﺍﻟﺘﻮﺻﻴﻼﺕ ﺍﻟﺼﺤﻴﺤﺔ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﺜﻞ ﻣﺠﻤﻮﻋﺔ ﺍﻟﺘﺮﻛﻴﺐ ﻫﺬﻩ‪.‬‬
‫‪Ar-١‬‬
‫‪29/3/2559 8:43:33‬‬
‫‪9381069118_IM_AR.indd 1‬‬
‫ﻣﻜﻴﻒ ﻫﻮﺍﺀ‬
‫ﺍﻟﻮﺣﺪﺓ ﺍﻟﺨﺎﺭﺟﻴﺔ‬
‫ﺧﺎﺹ ﺑﻤﺨﺘﺼﻲ ﺍﻟﺼﻴﺎﻧﺔ ﻓﻘﻂ‪.‬‬
‫ﻋﺮ ﺑﻲ‬
‫ﺩﻟﻴﻞ ﺗﻌﻠﻴﻤﺎﺕ ﺍﻟﺘﺮﻛﻴﺐ‬
‫ﺭﺍﺟﻊ ﻣﻠﺼﻖ ﺍﻟﺘﻘﺪﻳﺮ ﻣﻊ ﺍﻟﺮﻗﻢ ﺍﻟﻤﺴﻠﺴﻞ‬
‫ﺻﻨﻊ ﻓﻲ ﺗﺎﻳﻼﻧﺪ‬
‫‪PART No. 9381069118‬‬
‫‪29/3/2559 8:43:33‬‬
‫‪9381069118_IM_AR.indd 1‬‬