advertisement
▼
Scroll to page 2
of 8
ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ )ﺍﻟﻧﻭﻉ ﻋﻠﻰ ﺷﻛﻝ ﻋﻠﻳﺑﺔ( ﻋﺭﺑﻲ ﺩﻟﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ ﺍﺣﺗﻔﻅ ﺑﻬﺫﺍ ﺍﻟﺩﻟﻳﻝ ﻟﻠﺭﺟﻭﻉ ﺇﻟﻳﻪ ﻓﻲ ﺍﻟﻣﺳﺗﻘﺑﻝ. AUXM018GLAH AUXM024GLAH AUXM030GLAH AUXK018GLAH AUXK024GLAH AUXK030GLAH AUXK034GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH ﺭﺍﺟﻊ ﺑﻁﺎﻗﺔ ﺗﺻﻧﻳﻑ ﺍﻟﻣﻧﺗﺞ ﻟﻠﺗﻌﺭﻑ ﻋﻠﻰ ﺍﻟﺭﻗﻡ ﺍﻟﻣﺳﻠﺳﻝ. ﺻُﻧﻊ ﻓﻲ ﺟﻣﻬﻭﺭﻳﺔ ﺍﻟﺻﻳﻥ ﺍﻟﺷﻌﺑﻳﺔ ﺭﻗﻡ ﺍﻟﺻﻧﻑ 9369313226-02 25/4/2017 PM 1:06:32 1 9369313226-02_OM_AR.indd ﺩﻟﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ ﺭﻗﻡ ﺍﻟﺻﻧﻑ 9369313226-02 ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻓﻲ ﻧﻅﺎﻡ ) VRFﺍﻟﻧﻭﻉ ﺍﻟﺷﺭﻳﻁﻲ( ﺍﻟﻣﺣﺗﻭﻳﺎﺕ ﺍﺣﺗﻳﺎﻁﺎﺕ ﺍﻟﺳﻼﻣﺔ 1 ............................................................................................ ﺃﺳﻣﺎء ﺍﻷﺟﺯﺍء 1 ................................................................................................ ﺍﻟﺗﺷﻐﻳﻝ ) MANUAL AUTOﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ(2 ............................................................. ﺍﺗﺟﺎﻩ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء 2 ............................................................................................. ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ )ﺍﺧﺗﻳﺎﺭﻱ( 2 ............................................................................... ﺗﻠﻣﻳﺣﺎﺕ ﺍﻟﺗﺷﻐﻳﻝ3 .............................................................................................. ﺍﻟﺗﻧﻅﻳﻑ ﻭﺍﻟﻌﻧﺎﻳﺔ3 .............................................................................................. ﺍﺳﺗﻛﺷﺎﻑ ﺍﻷﻋﻁﺎﻝ ﻭﺇﺻﻼﺣﻬﺎ4 ............................................................................... ﺍﻟﻣﻭﺍﺻﻔﺎﺕ5 .................................................................................................... ﺍﺣﺗﻳﺎﻁﺎﺕ ﺍﻟﺳﻼﻣﺔ ● ﻗﺑﻝ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﺟﻬﺎﺯ ،ﺍﻗﺭﺃ ﻫﺫﻩ "ﺍﻻﺣﺗﻳﺎﻁﺎﺕ" ﺑﺎﻟﻛﺎﻣﻝ ﻭﻗﻡ ﺑﺗﺷﻐﻳﻝ ﺍﻟﺟﻬﺎﺯ ﺑﺎﻟﻁﺭﻳﻘﺔ ﺍﻟﺻﺣﻳﺣﺔ. ● ﺍﻟﺗﻌﻠﻳﻣﺎﺕ ﺍﻟﻭﺍﺭﺩﺓ ﻓﻲ ﻫﺫﺍ ﺍﻟﻘﺳﻡ ﺗﺭﺗﺑﻁ ﺟﻣﻳﻌًﺎ ﺑﺎﻟﺳﻼﻣﺔ؛ ﺗﺄﻛﺩ ﻣﻥ ﺍﻟﺣﻔﺎﻅ ﻋﻠﻰ ﻅﺭﻭﻑ ﺍﻟﺗﺷﻐﻳﻝ ﺍﻵﻣﻧﺔ. ● ﺗﺷﻳﺭ ﻋﺑﺎﺭﺗﻲ "ﺗﺣﺫﻳﺭ" ﻭ"ﺗﻧﺑﻳﻪ" ﻓﻲ ﻫﺫﻩ ﺍﻟﺗﻌﻠﻳﻣﺎﺕ ﺇﻟﻰ ﺍﻟﻣﻌﺎﻧﻲ ﺍﻟﺗﺎﻟﻳﺔ: ﺗﺣﺫﻳﺭ ﺗﺷﻳﺭ ﻫﺫﻩ ﺍﻟﻌﻼﻣﺔ ﺇﻟﻰ ﺍﻹﺟﺭﺍءﺍﺕ ،ﺍﻟﺗﻲ ﻓﻲ ﺣﺎﻟﺔ ﺗﻧﻔﻳﺫﻫﺎ ﺑﺷﻛﻝ ﻏﻳﺭ ﺻﺣﻳﺢ ،ﻗﺩ ﺗﺅﺩﻱ ﺇﻟﻰ ﺍﻟﻭﻓﺎﺓ ﺃﻭ ﺍﻹﺻﺎﺑﺔ ﺍﻟﺧﻁﻳﺭﺓ ﻟﻠﻣﺳﺗﺧﺩﻡ. ﺗﻧﺑﻳﻪ ﺗﺷﻳﺭ ﻫﺫﻩ ﺍﻟﻌﻼﻣﺔ ﺇﻟﻰ ﺍﻹﺟﺭﺍءﺍﺕ ،ﺍﻟﺗﻲ ﻓﻲ ﺣﺎﻟﺔ ﻋﺩﻡ ﺗﻧﻔﻳﺫﻫﺎ ﺑﺷﻛﻝ ﺻﺣﻳﺢ ،ﻗﺩ ﺗﺅﺩﻱ ﺿﺭﺭ ﺷﺧﺻﻲ ﻟﻠﻣﺳﺗﺧﺩﻡ ﺃﻭ ﺗﻠﻑ ﻓﻲ ﺍﻟﻣﻣﺗﻠﻛﺎﺕ. ● ﻻ ﺗﻠﻣﺱ ﺍﻟﻣﻭﺍﺳﻳﺭ ﺃﺛﻧﺎء ﺍﻟﺗﺷﻐﻳﻝ. ● ﺗﺄﻛﺩ ﻣﻥ ﺇﺑﻌﺎﺩ ﺃﻱ ﺃﺟﻬﺯﺓ ﻛﻬﺭﺑﺎﺋﻳﺔ ﻋﻥ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺃﻭ ﺍﻟﺧﺎﺭﺟﻳﺔ ﺑﻣﻘﺩﺍﺭ 1ﻣﺗﺭ ﻋﻠﻰ ﺍﻷﻗﻝ. ● ﻫﺫﺍ ﺍﻟﺟﻬﺎﺯ ﻏﻳﺭ ﻣﺧﺻﺹ ﻟﻼﺳﺗﺧﺩﺍﻡ ﻣﻥ ﺟﺎﻧﺏ ﺍﻷﺷﺧﺎﺹ ﺍﻟﺫﻳﻥ ﻳﻌﺎﻧﻭﻥ ﻣﻥ ﻧﻘﺹ ﻓﻲ ﺍﻟﻘﺩﺭﺍﺕ ﺍﻟﺑﺩﻧﻳﺔ ﺃﻭ ﺍﻟﺷﻌﻭﺭﻳﺔ ﺃﻭ ﺍﻟﺫﻫﻧﻳﺔ )ﺑﻣﺎ ﻓﻳﻬﻡ ﺍﻷﻁﻔﺎﻝ( ﺃﻭ ﻳﻌﺎﻧﻭﻥ ﻣﻥ ﻧﻘﺹ ﺍﻟﺧﺑﺭﺓ ﻭﺍﻟﻣﻌﺭﻓﺔ ،ﻣﺎ ﻟﻡ ﻳﺗﻡ ﺍﻹﺷﺭﺍﻑ ﻋﻠﻳﻬﻡ ﺃﻭ ﺇﻋﻁﺎﺋﻬﻡ ﺍﻟﺗﻌﻠﻳﻣﺎﺕ ﺍﻟﻣﺗﻌﻠﻘﺔ ﺑﺎﺳﺗﺧﺩﺍﻡ ﺍﻟﺟﻬﺎﺯ ﻣﻥ ﺟﺎﻧﺏ ﺷﺧﺹ ﻣﺳﺅﻭﻝ ﻋﻥ ﺳﻼﻣﺗﻬﻡ .ﻳﺟﺏ ﺍﻹﺷﺭﺍﻑ ﻋﻠﻰ ﺍﻷﻁﻔﺎﻝ ﻟﻠﺗﺄﻛﺩ ﻣﻥ ﺃﻧﻬﻡ ﻻ ﻳﻌﺑﺛﻭﻥ ﺑﺎﻟﺟﻬﺎﺯ. ﻣﻼﺣﻅﺔ: ﺇﻥ ﺗﺑﺩﻳﻝ ﻭﺿﻊ ﺍﻟﺗﺷﻐﻳﻝ ﻓﻲ ﻧﻅﺎﻡ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺣﺭﺍﺭﺓ ﻗﺩ ﻳﺣﺗﺎﺝ ﺇﻟﻰ ﺑﻌﺽ ﺍﻟﻭﻗﺕ ﻟﻠﺗﺣﺿﻳﺭ ﻟﻠﺗﺷﻐﻳﻝ. ﻟﻠﺗﺷﻐﻳﻝ .ﺑﺭﺟﺎء ﻣﻼﺣﻅﺔ ﺃﻥ ﻫﺫﺍ ﻟﻳﺱ ﻋﻁﻼ. ﺍﺣﺗﻳﺎﻁﺎﺕ ﻋﻧﺩ ﺍﻟﺗﺭﻛﻳﺏ ﺗﻧﺑﻳﻪ ● ﻻ ﺗﺣﺎﻭﻝ ﺗﺭﻛﻳﺏ ﺟﻬﺎﺯ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺍﻟﺣﺎﻟﻲ ﺑﻧﻔﺳﻙ. ● ﻻ ﺗﺣﺗﻭﻱ ﻫﺫﻩ ﺍﻟﻭﺣﺩﺓ ﻋﻠﻰ ﺃﺟﺯﺍء ﻳﻣﻛﻥ ﺻﻳﺎﻧﺗﻬﺎ ﺑﻭﺍﺳﻁﺔ ﺍﻟﻣﺳﺗﺧﺩﻡ .ﺍﺣﺭﺹ ﺩﺍﺋﻣًﺎ ﻋﻠﻰ ﺍﺳﺗﺷﺎﺭﺓ ﻣﻭﻅﻔﻲ ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﻣﻌﺗﻣﺩﻳﻥ ﻓﻳﻣﺎ ﻳﺗﻌﻠﻕ ﺑﺄﻱ ﺇﺻﻼﺣﺎﺕ. ● ﻋﻧﺩ ﺍﻟﻧﻘﻝ ،ﺍﺳﺗﺷﺭ ﻣﻭﻅﻔﻲ ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﻣﻌﺗﻣﺩﻳﻥ ﺑﺷﺄﻥ ﻓﺻﻝ ﺗﻭﺻﻳﻝ ﺍﻟﻭﺣﺩﺓ ﻭﺗﺭﻛﻳﺑﻬﺎ. ● ﻳﺟﺏ ﺗﻭﺻﻳﻝ ﺍﻟﻭﺣﺩﺓ ﺑﺎﻷﺭﺽ. ● ﺗﺄﻛﺩ ﻣﻥ ﺗﻧﻔﻳﺫ ﺃﻋﻣﺎﻝ ﺍﻟﺻﺭﻑ )ﻣﻭﺍﺳﻳﺭ ﺍﻟﺻﺭﻑ( ﺑﺷﻛﻝ ﺻﺣﻳﺢ ﻣﻥ ﺃﺟﻝ ﺍﻟﺗﺻﺭﻳﻑ. ● ﺗﺟﻧﺏ ﺗﺭﻛﻳﺏ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺑﺎﻟﻘﺭﺏ ﻣﻥ ﻣﺻﺩﺭ ﻟﻬﺏ ﺃﻭ ﺟﻬﺎﺯ ﺗﺳﺧﻳﻥ ﺁﺧﺭ. ● ﻋﻧﺩ ﺗﺭﻛﻳﺏ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻭﺍﻟﺧﺎﺭﺟﻳﺔ ،ﻳﺟﺏ ﺍﺗﺧﺎﺫ ﺍﻻﺣﺗﻳﺎﻁﺎﺕ ﻟﻣﻧﻊ ﻭﺻﻭﻝ ﺍﻷﻁﻔﺎﻝ. ﺃﺳﻣﺎء ﺍﻷﺟﺯﺍء ﺍﺣﺗﻳﺎﻁﺎﺕ ﻋﻧﺩ ﺍﻻﺳﺗﺧﺩﺍﻡ ﺗﺣﺫﻳﺭ ﻋﻼﻣﺔ ﻣﺣﻔﻭﺭﺓ )(1 ● ﻻ ﺗﻌﺭﺽ ﻧﻔﺳﻙ ﻟﺗﻳﺎﺭ ﻫﻭﺍء ﻣﺑﺎﺷﺭ ﻣﻥ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻟﻔﺗﺭﺓ ﻁﻭﻳﻠﺔ. ● ﺗﺟﻧﺏ ﺇﺩﺧﺎﻝ ﺍﻷﺻﺎﺑﻊ ﺃﻭ ﺍﻷﺟﺳﺎﻡ ﻓﻲ ﻣﻧﻔﺫ ﺍﻹﺧﺭﺍﺝ ﺃﻭ ﺷﺑﻛﺎﺕ ﺍﻻﻣﺗﺻﺎﺹ. ● ﺑﺎﺳﺗﺛﻧﺎء ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﻁﻭﺍﺭﺉ ،ﺗﺟﻧﺏ ﻣﻁﻠ ًﻘﺎ ﻓﺻﻝ ﺍﻟﺗﻳﺎﺭ ﺍﻟﺭﺋﻳﺳﻲ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﻗﺎﻁﻊ ﺍﻟﺗﻳﺎﺭ ﺍﻟﻔﺭﻋﻲ ﻟﻠﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺃﺛﻧﺎء ﺍﻟﺗﺷﻐﻳﻝ .ﺳﻭﻑ ﻳﺅﺩﻱ ﺫﻟﻙ ﺇﻟﻰ ﺗﻌﻁﻝ ﺍﻟﺿﺎﻏﻁ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺗﺳﺭﻳﺏ ﺍﻟﻣﻳﺎﻩ .ﻗﻡ ﺃﻭﻻ ﺑﺈﻳﻘﺎﻑ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻣﻥ ﺧﻼﻝ ﺗﺷﻐﻳﻝ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﺃﻭ ﺍﻟﻣﺣﻭﻝ ﺃﻭ ﺟﻬﺎﺯ ﺍﻹﺩﺧﺎﻝ ﺍﻟﺧﺎﺭﺟﻲ ﺛﻡ ﻗﻡ ﺑﻔﺻﻝ ﺍﻟﻘﺎﻁﻊ .ﺗﺄﻛﺩ ﻣﻥ ﺍﻟﺗﺷﻐﻳﻝ ﻣﻥ ﺧﻼﻝ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﺃﻭ ﺍﻟﻣﺣﻭﻝ ﺃﻭ ﺟﻬﺎﺯ ﺍﻹﺩﺧﺎﻝ ﺍﻟﺧﺎﺭﺟﻲ. ● ﻓﻲ ﺣﺎﻟﺔ ﺗﻠﻑ ﺳﻠﻙ ﻣﺻﺩﺭ ﺍﻟﻁﺎﻗﺔ ﻟﻬﺫﺍ ﺍﻟﺟﻬﺎﺯ ،ﻓﻼ ﻳﺟﺏ ﺍﺳﺗﺑﺩﺍﻟﻪ ﺇﻻ ﺑﻭﺍﺳﻁﺔ ﻣﻭﻅﻑ ﺻﻳﺎﻧﺔ ﻣﻌﺗﻣﺩ، ﻧﻅﺭً ﺍ ﻷﻥ ﻣﻥ ﺍﻟﻼﺯﻡ ﺍﺳﺗﺧﺩﺍﻡ ﺃﺩﻭﺍﺕ ﻷﻏﺭﺍﺽ ﻣﺧﺻﺻﺔ ﻭﺳﻠﻙ ﻣﺧﺻﺹ. (2)-2 (2)-1 )(3 (2)-3 (2)-4 ● ﻓﻲ ﺣﺎﻟﺔ ﺣﺩﻭﺙ ﺗﺳﺭﻳﺏ ﻟﺳﺎﺋﻝ ﺍﻟﺗﺑﺭﻳﺩ ،ﻓﻳﺟﺏ ﺇﻁﻔﺎء ﺃﻱ ﻟﻬﺏ ،ﻭﺗﻬﻭﻳﺔ ﺍﻟﻐﺭﻓﺔ ﻭﺍﻻﺗﺻﺎﻝ ﺑﻣﻭﻅﻔﻲ ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﻣﻌﺗﻣﺩﻳﻥ. ) (1ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء )ﻓﻲ ﺷﺑﻛﺔ ﺍﻣﺗﺻﺎﺹ ﺍﻟﻬﻭﺍء( ﺗﻧﺑﻳﻪ ● ﻻ ﺗﺿﻊ ﺍﻟﺣﻳﻭﺍﻧﺎﺕ ﺃﻭ ﺍﻟﻧﺑﺎﺗﺎﺕ ﻓﻲ ﺍﻟﻣﺳﺎﺭ ﺍﻟﻣﺑﺎﺷﺭ ﻟﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء. ● ﻻ ﺗﻭﺟﻪ ﺗﻳﺎﺭ ﺍﻟﻬﻭﺍء ﺇﻟﻰ ﺃﻣﺎﻛﻥ ﺍﻟﻠﻬﺏ ﺃﻭ ﺃﺟﻬﺯﺓ ﺍﻟﺗﺳﺧﻳﻥ. ● ﻻ ﺗﻘﻡ ﺑﺳﺩ ﺃﻭ ﺗﻐﻁﻳﺔ ﻣﻧﻔﺫ ﺍﻹﺩﺧﺎﻝ ﺃﻭ ﻣﻧﻔﺫ ﺍﻹﺧﺭﺍﺝ. ● ﻻ ﺗﺗﺳﻠﻕ ﻋﻠﻰ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺃﻭ ﺗﺿﻊ ﺍﻷﺷﻳﺎء ﻋﻠﻳﻪ. ● ﻻ ﺗﺿﻊ ﺍﻟﺯﻫﺭﻳﺎﺕ ﺃﻭ ﺣﺎﻭﻳﺎﺕ ﺍﻟﻣﻳﺎﻩ ﺃﻋﻠﻰ ﺃﺟﻬﺯﺓ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء. ● ﻻ ﺗﻘﻡ ﺑﺗﻌﻠﻳﻕ ﺍﻷﺷﻳﺎء ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ. ● ﻻ ﺗﺿﻊ ﺃﻱ ﺷﻲء ﻳﻧﺑﻐﻲ ﻋﺩﻡ ﺗﻌﺭﺿﻪ ﻟﻠﺑﻝ ﺃﺳﻔﻝ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ. ● ﺍﺣﺭﺹ ﺩﺍﺋﻣًﺎ ﻋﻠﻰ ﻓﺻﻝ ﺍﻟﻘﺎﻁﻊ ﺍﻟﻛﻬﺭﺑﺎﺋﻲ ﻋﻧﺩ ﺗﻧﻅﻳﻑ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺃﻭ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء. ● ﻻ ﺗﻘﻡ ﺑﺳﻛﺏ ﺍﻟﻣﻳﺎﻩ ﺃﻭ ﻣﺣﻠﻭﻝ ﺍﻟﺗﻧﻅﻳﻑ ﻋﻠﻰ ﺍﻟﻭﺣﺩﺓ ﻣﺑﺎﺷﺭﺓ ،ﺃﻭ ﻏﺳﻝ ﺍﻟﻭﺣﺩﺓ ﺑﺎﺳﺗﺧﺩﺍﻡ ﻫﺫﻩ ﺍﻟﻣﻭﺍﺩ. ● ﺗﺟﻧﺏ ﺗﻌﺭﻳﺽ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻟﻠﻣﺎء ﺑﺷﻛﻝ ﻣﺑﺎﺷﺭ. ● ﻻ ﺗﻘﻡ ﺑﺗﺷﻐﻳﻝ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺑﻳﺩﻳﻥ ﻣﺑﺗﻠﺔ. ● ﺍﻓﺣﺹ ﺣﺎﻟﺔ ﺣﺎﻣﻝ ﺍﻟﺗﺭﻛﻳﺏ ً ﺑﺣﺛﺎ ﻋﻥ ﺗﻠﻑ. ● ﻻ ﺗﻘﻡ ﺑﺎﻟﺗﺷﻐﻳﻝ ﺇﻻ ﻣﻊ ﺗﺭﻛﻳﺏ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء. ● ﻻ ﺗﺷﺭﺏ ﺍﻟﻣﺎء ﺍﻟﻣﺗﺻﺭﻑ ﻣﻥ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء. ● ﻻ ﺗﻌﺭﺽ ﺯﻋﺎﻧﻑ ﺍﻟﻣُﺷﻊ ﻷﻱ ﺿﻐﻁ ﺷﺩﻳﺩ. ● ﻻ ﺗﺳﺗﺧﺩﻡ ﻏﺎﺯﺍﺕ ﻗﺎﺑﻠﺔ ﻟﻼﺷﺗﻌﺎﻝ ﺑﺎﻟﻘﺭﺏ ﻣﻥ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء. ) (2ﺳﺩﺍﺋﻝ ﺍﺗﺟﺎﻩ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ﺃﺳﻣﺎء ﻣﻧﺎﻓﺫ ﺍﻹﺧﺭﺍﺝ )ﻓﻲ "ﺇﻋﺩﺍﺩ ﺗﺛﺑﻳﺕ VTﺍﻟﻔﺭﺩﻱ" ﺑﻭﺍﺳﻁﺔ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺳﻠﻛﻳﺔ(. ) :1-(2ﻣﺧﺭﺝ 1 ) :2-(2ﻣﺧﺭﺝ 2 ) :3-(2ﻣﺧﺭﺝ 3 ) :4-(2ﻣﺧﺭﺝ 4 ﻳُﺭﺟﻰ ﺍﻟﺭﺟﻭﻉ ﺇﻟﻰ "ﺇﻋﺩﺍﺩ ﺍﺗﺟﺎﻩ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء". ) (3ﺷﺑﻛﺔ ﺍﻣﺗﺻﺎﺹ ﺍﻟﻬﻭﺍء ) (4ﻟﻭﺣﺔ ﺍﻟﺗﺣﻛﻡ )ﺍﺧﺗﻳﺎﺭﻱ( )(5 )(4 )(8 )(7 )(6 ) (5ﻣﺳﺗﻘﺑﻝ ﺇﺷﺎﺭﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﻭﺯﺭ ) Manual autoﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( :ﻣﺳﺗﻘﺑﻝ ﺇﺷﺎﺭﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﻫﻭ ﻣﻛﺎﻥ ﺗﻠﻘﻲ ﺍﻹﺷﺎﺭﺍﺕ ﻣﻥ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ .ﻳُﺳﺗﺧﺩﻡ ﺯﺭ ) MANUAL AUTOﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( ﻟﺗﺷﻐﻳﻝ ﺍﻟﺟﻬﺎﺯ ﻓﻲ ﺣﺎﻟﺔ ﻋﺩﻡ ﺗﻭﺍﻓﺭ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ. Ar-1 25/4/2017 PM 1:06:30 9369313226-02_OM_AR.indd 1 ) (6ﻣﺅﺷﺭ ﻣﺻﺑﺎﺡ ﺍﻟﻣﺅﻗﺕ )ﺍﻟﺑﺭﺗﻘﺎﻟﻲ( :ﻳﺿﻲء ﻋﻧﺩﻣﺎ ﻳﻛﻭﻥ ﺍﻟﻣﺅﻗﺕ ﻗﻳﺩ ﺍﻟﺗﺷﻐﻳﻝ. ) (7ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( :ﻳﺿﻲء ﺃﺛﻧﺎء ﺍﻟﺗﺷﻐﻳﻝ. ً ) (8ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺭﺷﺢ )ﺍﻷﺣﻣﺭ( :ﻳﺿﻲء ﻋﻧﺩﻣﺎ ﻳﺻﺑﺢ ﺍﻟﻣﺭﺷﺢ ﻣﺗﺳﺧﺎ .ﻗﻡ ﺑﺗﻧﻅﻳﻑ ﺍﻟﻣﺭﺷﺢ ﻣﻥ ﺧﻼﻝ ﺍﻟﺭﺟﻭﻉ ﺇﻟﻰ ﻗﺳﻡ "ﺍﻟﺗﻧﻅﻳﻑ ﻭﺍﻟﻌﻧﺎﻳﺔ" .ﻳﻧﻁﻔﺊ ﻋﻧﺩ ﺿﻐﻁ ﺯﺭ ) RESETﺇﻋﺎﺩﺓ ﺗﻌﻳﻳﻥ( ﺑﻌﺩ ﺍﻟﺗﻧﻅﻳﻑ. ﺗﺛﺑﻳﺕ VTﺍﻟﻔﺭﺩﻱ ﻳﻣﻛﻧﻙ ﺇﻋﺩﺍﺩ ﺍﺗﺟﺎﻩ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ﻟﻣﻧﺎﻓﺫ ﺍﻟﻣﺧﺎﺭﺝ ﻓﺭﺩﻳًﺎ ﺑﺎﺳﺗﺧﺩﺍﻡ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ. ﻳﻣﻛﻥ ﺇﺟﺭﺍء "ﺇﻋﺩﺍﺩ ﺗﺛﺑﻳﺕ VTﺍﻟﻔﺭﺩﻱ" ﻣﻥ ﺧﻼﻝ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﻛﺎﻟﺗﺎﻟﻲ. ● *) UTY-RNR*Zﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺳﻠﻛﻳﺔ( ) (9ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ )ﺍﺧﺗﻳﺎﺭﻱ( ﺭﺍﺟﻊ ﺩﻟﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ ﻟﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ. ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ )ﺍﺧﺗﻳﺎﺭﻱ( ﺣﻭﻝ ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ )(9 ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ )ﺍﺧﺗﻳﺎﺭﻱ( ﻳﻛﺗﺷﻑ ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ ﻭﺟﻭﺩ ﺃﺷﺧﺎﺹ ﻓﻲ ﺍﻟﻐﺭﻓﺔ ﻣﻥ ﻋﺩﻣﻪ ﻣﻥ ﺧﻼﻝ ﺗﺗﺑﻊ ﺣﺭﻛﺔ ﺍﻷﺷﺧﺎﺹ ﻓﻲ ﺍﻟﻐﺭﻓﺔ. *ﻳﻘﺗﺻﺭ ﻓﻘﻁ ﻋﻠﻰ ﻁﻘﻡ ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ ﺍﻟﻣﺭﻓﻕ. ﻳﻣﻛﻥ ﺇﺟﺭﺍء ﺇﻋﺩﺍﺩ ﻟﻠﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ ﻓﻲ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻛﺎﻟﺗﺎﻟﻲ .ﺭﺍﺟﻊ ﺩﻟﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ ﻟﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ. ● *) UTY-RNR*Zﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺳﻠﻛﻳﺔ( ﺃﻧﻭﺍﻉ ﻭﺣﺩﺍﺕ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ: ● ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﻼﺳﻠﻛﻳﺔ ● ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺳﻠﻛﻳﺔ ● ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺑﺳﻳﻁﺔ ﺣﻭﻝ ﻭﻅﻳﻔﺔ ﺍﻟﺣﻔﻅ ﺍﻟﺗﻠﻘﺎﺋﻲ ﻟﻠﺗﻌﺭﻑ ﻋﻠﻰ ﻁﺭﻳﻘﺔ ﺍﻟﺗﺷﻐﻳﻝ ،ﻳﺭﺟﻰ ﺍﻟﺭﺟﻭﻉ ﺇﻟﻰ ﺩﻟﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ ﻟﻛﻝ ﺟﻬﺎﺯ. ﺍﻟﺗﺷﻐﻳﻝ ) MANUAL AUTOﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( ﺍﺳﺗﺧﺩﻡ ﺍﻟﺗﺷﻐﻳﻝ ) MANUAL AUTOﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( ﻓﻲ ﺣﺎﻟﺔ ﻓﻘﺩ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺃﻭ ﺃﺻﺑﺣﺕ ﻏﻳﺭ ﻣﺗﻭﺍﻓﺭﺓ ﺑﺷﻛﻝ ﺁﺧﺭ. *ﻳﻘﺗﺻﺭ ﻓﻘﻁ ﻋﻠﻰ ﻁﻘﻡ ﻣﺳﺗﻘﺑﻝ IRﺍﻟﻣﺭﻓﻕ. ﺗﻧﺑﻳﻪ ﺇﺫﺍ ﻟﻡ ﻳﺩﺧﻝ ﺃﺣﺩ ﺍﻟﻐﺭﻓﺔ ﺧﻼﻝ ﺍﻟﻭﻗﺕ ﺍﻟﺫﻱ ﺗﻡ ﺇﻋﺩﺍﺩﻩ ) 15ﻭ 30ﻭ 60ﻭ 90ﻭ 120ﻭ 180ﺩﻗﻳﻘﺔ( ،ﻳﺗﻡ ﺍﻟﺗﺣﻛﻡ ﺗﻠﻘﺎﺋﻳًﺎ )ﺗﻌﻳﻳﻥ( ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﺍﻟﺗﻲ ﺗﻡ ﺇﻋﺩﺍﺩﻫﺎ. )ﻋﻧﺩﻣﺎ ﻳﻌﻭﺩ ﺷﺧﺹ ﺇﻟﻰ ﺍﻟﻐﺭﻓﺔ ،ﻳﻛﺗﺷﻑ ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ ﻫﺫﺍ ﻭﻳﻘﻭﻡ ﺑﺎﻟﺭﺟﻭﻉ ﺗﻠﻘﺎﺋﻳًﺎ ﺇﻟﻰ ﺍﻹﻋﺩﺍﺩ ﺍﻷﺻﻠﻲ(. ﺣﻭﻝ ﻭﻅﻳﻔﺔ ﺇﻳﻘﺎﻑ ﺍﻟﺗﺷﻐﻳﻝ ﺍﻟﺗﻠﻘﺎﺋﻲ ﺇﺫﺍ ﻟﻡ ﻳﺩﺧﻝ ﺃﺣﺩ ﺍﻟﻐﺭﻓﺔ ﺧﻼﻝ ﺍﻟﻭﻗﺕ ﺍﻟﺫﻱ ﺗﻡ ﺇﻋﺩﺍﺩﻩ ) 1ﺇﻟﻰ 24ﺳﺎﻋﺔ ﻭﻓﻕ ﻗﻳﻡ ﺗﺯﺍﻳﺩﻳﻪ 1ﺳﺎﻋﺔ( ،ﻳﺗﻭﻗﻑ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻋﻥ ﺍﻟﺗﺷﻐﻳﻝ ﺗﻠﻘﺎﺋﻳًﺎ. ﻣﻼﺣﻅﺎﺕ: ﻻ ﺗﺿﻐﻁ ﺯﺭ ) MANUAL AUTOﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( ﺑﺄﻳﺩﻱ ﻣﺑﺗﻠﺔ ﺃﻭ ﺃﺟﺳﺎﻡ ﻣﺩﺑﺑﺔ ،ﻓﻲ ﺣﺎﻟﺔ ﻋﺩﻡ ﻣﺭﺍﻋﺎﺓ ﺫﻟﻙ ﻗﺩ ﺗﺣﺩﺙ ﺻﺩﻣﺔ ﻛﻬﺭﺑﺎﺋﻳﺔ ﺃﻭ ﺗﻌﻁﻝ. ﺑﺩء ﺍﻟﺗﺷﻐﻳﻝ ﺍﺿﻐﻁ ﺯﺭ ) MANUAL AUTOﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( ﻋﻠﻰ ﻟﻭﺣﺔ ﺍﻟﺗﺣﻛﻡ ﻓﻲ ﺍﻟﺗﺷﻐﻳﻝ. ● ﻹﻋﺎﺩﺓ ﺑﺩء ﺍﻟﺗﺷﻐﻳﻝ ،ﺍﺿﻐﻁ ﻋﻠﻰ ﺯﺭ ]) On/Offﺗﺷﻐﻳﻝ/ﺇﻳﻘﺎﻑ([ ﻓﻲ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ. ● ﻗﺩ ﻻ ﺗﻌﻣﻝ ﻭﻅﻳﻔﺔ ﺇﻳﻘﺎﻑ ﺍﻟﺗﺷﻐﻳﻝ ﺍﻟﺗﻠﻘﺎﺋﻲ ﺣﺗﻰ ﻟﻭ ﻟﻡ ﻳﻛﻥ ﻫﻧﺎﻙ ﺷﺧﺹ ﻓﻲ ﺍﻟﻐﺭﻓﺔ .ﻗﺩ ﻳﻛﺗﺷﻑ ﺍﻟﻣﺳﺗﺷﻌﺭ ﻭﺟﻭﺩ ﺃﺷﺧﺎﺹ ﺑﺷﻛﻝ ﻏﻳﺭ ﺻﺣﻳﺢ ﺣﺗﻰ ﻟﻭ ﻟﻡ ﻳﻛﻥ ﻫﻧﺎﻙ ﺷﺧﺹ ﻓﻲ ﺍﻟﻐﺭﻓﺔ. ﻧﻁﺎﻕ ﺍﻻﺳﺗﻌﻣﺎﻝ ﻳﻣﻛﻥ ﺿﺑﻁ ﺍﻟﺗﺷﻐﻳﻝ ﺣﺳﺏ ﺍﻹﻋﺩﺍﺩ ﺍﻟﺗﺎﻟﻲ. ) AUTOﺗﻠﻘﺎﺋﻲ(: ﻭﺿﻊ ﺍﻟﺗﺷﻐﻳﻝ ﻓﻲ ﺣﺎﻟﺔ ﺗﻌﺫﺭ ﺗﺣﺩﻳﺩ ﺍﻟﻭﺿﻊ ﺍﻟﺗﻠﻘﺎﺋﻲ ،ﻓﺈﻧﻪ ﻳﻌﻣﻝ ﺑﻧﻔﺱ ﻭﺿﻊ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺍﻷﺧﺭﻯ ﻋﻠﻰ ﻧﻔﺱ ﺍﻟﻧﻅﺎﻡ) .ﻭﺇﺫﺍ ﻛﺎﻧﺕ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺍﻷﺧﺭﻯ ﻋﻠﻰ ﻧﻔﺱ ﺍﻟﻧﻅﺎﻡ ﻻ ﺗﻌﻣﻝ ،ﺳﻭﻑ ﻳﻌﻣﻝ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻋﻠﻰ ﻭﺿﻊ ﺍﻟﺗﺑﺭﻳﺩ(. ) Fan Speedﺳﺭﻋﺔ ﺍﻟﻣﺭﻭﺣﺔ( ) AUTOﺗﻠﻘﺎﺋﻲ( 23ﺩﺭﺟﺔ ﻣﺋﻭﻳﺔ ﺇﻋﺩﺍﺩ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﺗﻧﺑﻳﻪ ● ﻻ ﺗﺿﻊ ﺃﺷﻳﺎء ﻛﺑﻳﺭﺓ ﺍﻟﺣﺟﻡ ﺑﺎﻟﻘﺭﺏ ﻣﻥ ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ .ﺃﻳﺿًﺎ ﺍﺟﻌﻝ ﻭﺣﺩﺍﺕ ﺍﻟﺗﺩﻓﺋﺔ ﺧﺎﺭﺝ ﻣﻧﻁﻘﺔ ﺍﻻﻛﺗﺷﺎﻑ ﻟﻠﻣﺳﺗﺷﻌﺭ. ﻣﺩﻯ ﺍﻟﺣﺳﺎﺳﻳﺔ ﺍﻟﻣﻛﺎﻓﺊ ﻟﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﺍﺭﺗﻔﺎﻉ ﺍﻟﺳﻘﻑ 3.2 :ﻣﺗﺭ ﻭﺿﻊ ﺍﻻﻛﺗﺷﺎﻑ 0.8 :ﻣﺗﺭ ﻣﻥ ﺳﻁﺢ ﺍﻷﺭﺽ 3.2ﻣﺗﺭ 8.8ﻣﺗﺭ 0.8ﻣﺗﺭ ﺇﻳﻘﺎﻑ ﺍﻟﺗﺷﻐﻳﻝ ﻣﻼﺣﻅﺎﺕ: ﺍﺿﻐﻁ ﺯﺭ ) MANUAL AUTOﻳﺩﻭﻱ ﺗﻠﻘﺎﺋﻲ( ﻋﻠﻰ ﻟﻭﺣﺔ ﺍﻟﺗﺣﻛﻡ ﻓﻲ ﺍﻟﺗﺷﻐﻳﻝ. ● ﻋﻧﺩﻣﺎ ﻳﻛﻭﻥ ﺍﺭﺗﻔﺎﻉ ﺍﻟﺗﺭﻛﻳﺏ ﺃﻛﺑﺭ ،ﺗﻘﻝ ﺣﺳﺎﺳﻳﺔ ﺍﺳﺗﺷﻌﺎﺭ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ. ﺍﺗﺟﺎﻩ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ● ﻗﺩ ﻻ ﺗﻌﻣﻝ ﻭﻅﻳﻔﺔ ﺗﻭﻓﻳﺭ ﺍﻟﻁﺎﻗﺔ ﺑﺷﻛﻝ ﺻﺣﻳﺢ ﻋﻧﺩﻣﺎ ﺗﻛﻭﻥ ﺣﺭﺍﺭﺓ ﺍﻟﻐﺭﻓﺔ ﻣﺧﺗﻠﻔﺔ ﻟﻠﻐﺎﻳﺔ ﻋﻥ ﺍﻟﺣﺭﺍﺭﺓ ﺍﻟﻣﺣﺩﺩﺓ ﻓﻲ ﺇﻋﺩﺍﺩ ﺍﻟﺣﺭﺍﺭﺓ ،ﻣﺛﻼ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﺍﻟﻣﻭﺟﻭﺩﺓ ﺑﻌﺩ ﺑﺩء ﺍﻟﺗﺷﻐﻳﻝ ﻣﺑﺎﺷﺭﺓ. ﻳﻣﻛﻥ ﺍﻟﺗﺣﻛﻡ ﻓﻲ ﺍﺗﺟﺎﻩ ﺍﻟﻬﻭﺍء ﺍﻟﺭﺃﺳﻲ ﻣﻥ ﺧﻼﻝ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ. ● ﻧﻅﺭً ﺍ ﻷﻥ ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ ﻳﻛﺗﺷﻑ ﺍﻹﺿﺎءﺓ ﺗﺣﺕ ﺍﻟﺣﻣﺭﺍء ﺍﻟﺻﺎﺩﺭﺓ ﻣﻥ ﺍﻷﺷﺧﺎﺹ ،ﻗﺩ ﺗﻛﻭﻥ ﻫﻧﺎﻙ ﺣﺎﻻﺕ ﻳﻛﻭﻥ ﻓﻳﻬﺎ ﻫﺫﺍ ﺍﻻﻛﺗﺷﺎﻑ ﻏﻳﺭ ﺻﺣﻳﺢ. ﺍﺗﺟﺎﻩ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ﺍﻟﺭﺃﺳﻲ )(1 )(2 )(3 )(4 ﺑﺎﺭﺩ ﻭﺟﺎﻑ(4) ،(3) ،(2) ،(1) : )(4) ،(3) ،(2) ،(1 ﺍﻟﺗﺩﻓﺋﺔ: Ar-2 25/4/2017 PM 1:06:28 9369313226-02_OM_AR.indd 2 ﺍﻟﻣﻭﺍﻗﻑ ﺍﻟﺗﻲ ﻳﻛﺗﺷﻑ ﻓﻳﻬﺎ ﺍﻟﻣﺳﺗﺷﻌﺭ ﻋﺩﻡ ﻭﺟﻭﺩ ﺃﺷﺧﺎﺹ ﻓﻲ ﺍﻟﻐﺭﻓﺔ ،ﺣﺗﻰ ﻋﻧﺩﻣﺎ ﻳﻛﻭﻥ ﻫﻧﺎﻙ ﺷﺧﺹ ﺑﻬﺎ ● ﻋﻧﺩﻣﺎ ﺗﻛﻭﻥ ﺍﻟﺣﺭﺍﺭﺓ ﻣﺭﺗﻔﻌﺔ ﻭﺍﻟﻔﺭﻕ ﺑﻳﻧﻬﺎ ﻭﺑﻳﻥ ﺣﺭﺍﺭﺓ ﺟﺳﻡ ﺍﻷﺷﺧﺎﺹ ﺻﻐﻳﺭ) .ﻣﺛﻼ ﺃﺛﻧﺎء ﺍﻟﺻﻳﻑ ﻋﻧﺩﻣﺎ ﺗﻛﻭﻥ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ 30ﺩﺭﺟﺔ ﻣﺋﻭﻳﺔ ﺃﻭ ﺃﻋﻠﻰ(. ● ﻋﻧﺩﻣﺎ ﻳﻛﻭﻥ ﻫﻧﺎﻙ ﺷﺧﺹ ﻓﻲ ﺍﻟﻐﺭﻓﺔ ،ﻟﻛﻧﻪ ﻻ ﻳﺗﺣﺭﻙ ﻟﻔﺗﺭﺓ ﻁﻭﻳﻠﺔ ﻣﻥ ﺍﻟﻭﻗﺕ. ● ﻋﻧﺩﻣﺎ ﻳﺗﺧﻔﻰ ﺍﻟﺷﺧﺹ ﺧﻠﻑ ﺍﻟﻛﻧﺑﺔ ،ﺃﻭ ﻗﻁﻌﺔ ﺃﺛﺎﺙ ﺃﺧﺭﻯ ،ﺃﻭ ﺯﺟﺎﺝ ﺃﻭ ﻓﻲ ﻣﻭﻗﻑ ﻣﻣﺎﺛﻝ. ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ ● ﻳﺗﻡ ﺑﺻﻔﺔ ﺩﻭﺭﻳﺔ ﺗﻧﻔﻳﺫ ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ ﻣﻥ ﺃﺟﻝ ﺇﻋﺎﺩﺓ ﺯﻳﺕ ﺍﻟﺿﺎﻏﻁ ﺇﻟﻰ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ. ﻭﺧﻼﻝ ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ ،ﻳﻭﻣﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( )ﻟﻣﺩﺓ 10ﺩﻗﺎﺋﻕ ﺗﻘﺭﻳﺑًﺎ(. ﻣﺩﻯ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻭﺍﻟﺭﻁﻭﺑﺔ ● ﻳﺗﻡ ﺗﻭﺿﻳﺢ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻭﺍﻟﺭﻁﻭﺑﺔ ﺍﻟﻣﻁﻠﻭﺑﺔ ﻟﺗﺷﻐﻳﻝ ﻫﺫﺍ ﺍﻟﻣﻧﺗﺞ ﻓﻲ ﺍﻟﺟﺩﻭﻝ ﺍﻟﺗﺎﻟﻲ. ● ﻋﻧﺩﻣﺎ ﻳﺭﺗﺩﻱ ﺍﻟﺷﺧﺹ ﻣﻼﺑﺱ ﺳﻣﻳﻛﺔ ﻟﻠﻐﺎﻳﺔ ﻭﻅﻬﺭﻩ ﻳﻭﺍﺟﻪ ﺍﻟﻣﺳﺗﺷﻌﺭ. ﺍﻟﻣﻭﺍﻗﻑ ﺍﻟﺗﻲ ﻳﻛﺗﺷﻑ ﻓﻳﻬﺎ ﺍﻟﻣﺳﺗﺷﻌﺭ ﻭﺟﻭﺩ ﺃﺷﺧﺎﺹ ﻓﻲ ﺍﻟﻐﺭﻓﺔ ﺑﺷﻛﻝ ﻏﻳﺭ ﺻﺣﻳﺢ ،ﺣﺗﻰ ﻋﻧﺩﻣﺎ ﻻ ﻳﻛﻭﻥ ﻫﻧﺎﻙ ﺷﺧﺹ ﺑﻬﺎ ● ﻋﻧﺩﻣﺎ ﻳﻛﻭﻥ ﻫﻧﺎﻙ ﻛﻠﺏ ﺃﻭ ﻗﻁﺔ ﺗﺗﺣﺭﻙ ﻓﻲ ﺍﻟﻐﺭﻓﺔ. ● ﻋﻧﺩﻣﺎ ﺗﺣﺭﻙ ﺍﻟﺭﻳﺎﺡ ﺍﻟﺳﺗﺎﺋﺭ ﺃﻭ ﺍﻟﻧﺑﺎﺗﺎﺕ. ● ﻋﻧﺩﻣﺎ ﺗﻭﺟﺩ ﻭﺣﺩﺍﺕ ﺗﺩﻓﺋﺔ ﺃﻭ ﺍﻷﺟﻬﺯﺓ ﺍﻟﻣﺭﻁﺑﺔ ﺃﻭ ﺃﺟﻬﺯﺓ ﻛﻬﺭﺑﺎﺋﻳﺔ ﻣﺛﻝ ﺗﺷﻐﻳﻝ ﺍﻟﻣﺭﺍﻭﺡ ﺍﻟﻛﻬﺭﺑﺎﺋﻳﺔ ﺍﻟﻣﺗﺫﺑﺫﺑﺔ. ﺗﻠﻣﻳﺣﺎﺕ ﺍﻟﺗﺷﻐﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ ﻭﺍﻷﺩﺍء ﺣﻭﻝ ﺣﺎﻟﺔ ﺍﻷﻭﻟﻭﻳﺔ ﻭﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ ● ﻳﻣﻛﻥ ﺗﻭﺻﻳﻝ ﻭﺣﺩﺍﺕ ﺩﺍﺧﻠﻳﺔ ﻣﺗﻌﺩﺩﺓ ﻋﻠﻰ ﻧﻔﺱ ﺍﻟﻧﻅﺎﻡ .ﻭﺗﺑﻌًﺎ ﻟﻠﻧﻅﺎﻡ ،ﻳﻛﻭﻥ ﺍﺧﺗﻳﺎﺭ ﻭﺿﻊ ﺍﻟﺗﺷﻐﻳﻝ ﻣﺣﺩﻭ ًﺩﺍ. ﻭﺿﻊ ﺑﺎﺭﺩ/ﺟﺎﻑ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻓﻲ ﺍﻟﺧﺎﺭﺝ ﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ: ﻳﺗﻡ ﺗﻧﺷﻳﻁ ﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ ﻋﻧﺩ ﺑﺩء ﺗﺷﻐﻳﻝ ﻭﺣﺩﺗﻳﻥ ) (2ﺃﻭ ﺃﻛﺛﺭ ﻣﻥ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻋﻠﻰ ﻭﺿﻊ ﻣﺧﺗﻠﻑ ﻓﻲ ﻧﻔﺱ ﺍﻟﻭﻗﺕ .ﻭﺗﻧﺗﻅﺭ ﺃﻱ ﻭﺣﺩﺓ ﺩﺍﺧﻠﻳﺔ ﺑﺧﻼﻑ ﺍﻟﻭﺣﺩﺍﺕ ﺫﺍﺕ ﻭﺿﻊ ﺍﻷﻭﻟﻳﺔ ﻋﻠﻰ ﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ ﺣﺗﻰ ﻳﺗﻐﻳﺭ ﻭﺿﻊ ﺍﻷﻭﻟﻭﻳﺔ )ﻭﻳﺑﺩﺃ ﺍﻟﺗﺷﻐﻳﻝ ﺑﻣﺟﺭﺩ ﺗﻐﻳﻳﺭ ﺍﻷﻭﻟﻭﻳﺔ(. ﻓﻲ ﻧﻔﺱ ﺍﻟﻭﻗﺕ ،ﻳﺿﻲء ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( ﻭﻳﻭﻣﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺅﻗﺕ )ﺍﻟﺑﺭﺗﻘﺎﻟﻲ(. ﺍﻟﺗﺑﺭﻳﺩ ﺍﻟﻣﺣﻳﻁ ﺍﻟﻣﻧﺧﻔﺽ ● ﻋﻧﺩﻣﺎ ﺗﻧﺧﻔﺽ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻓﻲ ﺍﻟﺧﺎﺭﺝ ،ﻗﺩ ﻳﺗﻡ ﺗﻐﻳﻳﺭ ﻣﺭﺍﻭﺡ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ ﺇﻟﻰ ﺳﺭﻋﺔ ﻣﻧﺧﻔﺿﺔ، ﺃﻭ ﻗﺩ ﺗﺗﻭﻗﻑ ﺇﺣﺩﻯ ﺍﻟﻣﺭﺍﻭﺡ ﺑﺷﻛﻝ ﻣﺗﻘﻁﻊ. ﺃﺩﺍء ﺍﻟﺗﺩﻓﺋﺔ ● ﻳﻌﻣﻝ ﻭﺿﻊ ﺍﻟﺗﺩﻓﺋﺔ ﺑﻣﺑﺩﺃ ﻣﺿﺧﺔ ﺍﻟﺣﺭﺍﺭﺓ ،ﺣﻳﺙ ﻳﺗﻡ ﺍﻣﺗﺻﺎﺹ ﺍﻟﺣﺭﺍﺭﺓ ﻣﻥ ﺍﻟﻬﻭﺍء ﻓﻲ ﺍﻟﺧﺎﺭﺝ ﻭﻧﻘﻝ ﺗﻠﻙ ﺍﻟﺣﺭﺍﺭﺓ ﺇﻟﻰ ﺍﻟﺩﺍﺧﻝ .ﻧﺗﻳﺟﺔ ﻟﺫﻟﻙ ،ﻳﻘﻝ ﺃﺩﺍء ﺍﻟﺗﺷﻐﻳﻝ ﻣﻊ ﺍﻧﺧﻔﺎﺽ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻓﻲ ﺍﻟﺧﺎﺭﺝ .ﺇﺫﺍ ﺷﻌﺭﺕ ﺃﻥ ﺃﺩﺍء ﺍﻟﺗﺩﻓﺋﺔ ﺍﻟﻧﺎﺗﺞ ﻏﻳﺭ ﻛﺎﻑٍ ،ﻋﻧﺩﺋﺫ ﻳﻭﺻﻰ ﺑﺎﺳﺗﺧﺩﺍﻡ ﺟﻬﺎﺯ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺍﻟﺣﺎﻟﻲ ﻣﻊ ﻧﻭﻉ ﺁﺧﺭ ﻣﻥ ﺃﺟﻬﺯﺓ ﺍﻟﺗﺩﻓﺋﺔ. ● ﻳﻘﻭﻡ ﻭﺿﻊ ﺍﻟﺗﺩﻓﺋﺔ ﺑﺗﺩﻓﺋﺔ ﺍﻟﻐﺭﻓﺔ ﺑﺎﻟﻛﺎﻣﻝ ﻣﻥ ﺧﻼﻝ ﺇﻋﺎﺩﺓ ﺗﺩﻭﻳﺭ ﺍﻟﻬﻭﺍء ﻓﻲ ﻛﺎﻓﺔ ﺃﺭﺟﺎء ﺍﻟﻐﺭﻓﺔ ،ﺣﻳﺙ ﻳﺗﻡ ﺍﻟﺣﺻﻭﻝ ﻋﻠﻰ ﺍﻟﻧﺗﻳﺟﺔ ﻓﻲ ﺑﻌﺽ ﺍﻷﺣﻳﺎﻥ ﺑﻌﺩ ﺑﺩء ﺗﺷﻐﻳﻝ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﺃﻭﻻ ﺣﺗﻰ ﺗﺗﻡ ﺗﺩﻓﺋﺔ ﺍﻟﻐﺭﻓﺔ. ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ ﺑﻭﺍﺳﻁﺔ ﻛﻣﺑﻳﻭﺗﺭ ﺻﻐﻳﺭ ● ﻋﻧﺩ ﺍﺳﺗﺧﺩﺍﻡ ﻭﺿﻊ ﺍﻟﺗﺩﻓﺋﺔ ﻓﻲ ﻅﺭﻭﻑ ﺍﻧﺧﻔﺎﺽ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺍﻟﻬﻭﺍء ﻓﻲ ﺍﻟﺧﺎﺭﺝ ﻭﺍﺭﺗﻔﺎﻉ ﺍﻟﺭﻁﻭﺑﺔ ،ﻗﺩ ﻳﺗﻛﻭﻥ ﺻﻘﻳﻊ ﻋﻠﻰ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ ،ﻣﻣﺎ ﻳﺅﺩﻱ ﺇﻟﻰ ﺗﻘﻠﻳﻝ ﺃﺩﺍء ﺍﻟﺗﺷﻐﻳﻝ .ﻭﻣﻥ ﺃﺟﻝ ﺗﻔﺎﺩﻱ ﻫﺫﺍ ﺍﻟﻧﻭﻉ ﻣﻥ ﺍﻷﺩﺍء ﺍﻟﻣﻧﺧﻔﺽ ،ﻳﺗﻡ ﺗﺯﻭﻳﺩ ﻫﺫﻩ ﺍﻟﻭﺣﺩﺓ ﺑﻭﻅﻳﻔﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ ﻭﺍﻟﺗﻲ ﻳﺗﻡ ﺍﻟﺗﺣﻛﻡ ﻓﻳﻬﺎ ﺑﻭﺍﺳﻁﺔ ﻛﻣﺑﻳﻭﺗﺭ ﺻﻐﻳﺭ .ﻓﻲ ﺣﺎﻟﺔ ﺗﻛﻭﻥ ﺍﻟﺻﻘﻳﻊ ،ﻳﺗﻭﻗﻑ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻋﻥ ﺍﻟﻌﻣﻝ ﻣﺅﻗ ًﺗﺎ ،ﻭﻳﺗﻡ ﺗﺷﻐﻳﻝ ﺩﺍﺋﺭﺓ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﻟﻔﺗﺭﺓ ﻭﺟﻳﺯﺓ )ﺣﻭﺍﻟﻲ 4ﺇﻟﻰ 15ﺩﻗﻳﻘﺔ(. ﺃﺛﻧﺎء ﺗﺷﻐﻳﻝ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺍﻷﻭﺗﻭﻣﺎﺗﻳﻛﻲ ،ﻳﻭﻣﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ(. ﻳﺭﺟﻰ ﺍﻟﺭﺟﻭﻉ ﺇﻟﻰ ﻣﻭﺍﺻﻔﺎﺕ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺧﺎﺭﺟﻳﺔ. ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻓﻲ ﺍﻟﺩﺍﺧﻝ 18ﺇﻟﻰ 32ﺩﺭﺟﺔ ﻣﺋﻭﻳﺔ DB ﺍﻟﺭﻁﻭﺑﺔ ﻓﻲ ﺍﻟﺩﺍﺧﻝ ﺣﻭﺍﻟﻲ 80%ﺃﻭ ﺃﻗﻝ 10ﺇﻟﻰ 30ﺩﺭﺟﺔ ﻣﺋﻭﻳﺔ DB ● ﻓﻲ ﺣﺎﻟﺔ ﺗﺷﻐﻳﻝ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻓﻲ ﻅﺭﻭﻑ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺃﻋﻠﻰ ﻣﻥ ﺗﻠﻙ ﺍﻟﻣﺑﻳﻧﺔ ،ﻳﺗﻡ ﺗﺷﻐﻳﻝ ﺩﺍﺋﺭﺓ ﺍﻟﺣﻣﺎﻳﺔ ﺍﻟﻣﺿﻣﻧﺔ ﻟﻣﻧﻊ ﺗﻠﻑ ﺍﻟﺩﺍﺋﺭﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ .ﺃﻳﺿًﺎ ﻓﻲ ﻭﺿﻊ ﺑﺎﺭﺩ ﻭﻭﺿﻊ ﺟﺎﻑ ،ﺇﺫﺍ ﺗﻡ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﻭﺣﺩﺓ ﻓﻲ ﻅﺭﻭﻑ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺃﻗﻝ ﻣﻥ ﺗﻠﻙ ﺍﻟﻣﺑﻳﻧﺔ ﺃﻋﻼﻩ ،ﻓﻘﺩ ﻳﺗﺟﻣﺩ ﻣﺑﺎﺩﻝ ﺍﻟﺣﺭﺍﺭﺓ ،ﻣﻣﺎ ﻳﺅﺩﻱ ﺇﻟﻰ ﺗﺳﺭﻳﺏ ﻣﻳﺎﻩ ﻭﺗﻠﻔﻳﺎﺕ ﺃﺧﺭﻯ. ● ﺇﺫﺍ ﺗﻡ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﻭﺣﺩﺓ ﻟﻔﺗﺭﺍﺕ ﻁﻭﻳﻠﺔ ﻓﻲ ﻅﺭﻭﻑ ﻣﺭﺗﻔﻌﺔ ﺍﻟﺭﻁﻭﺑﺔ ،ﻓﻘﺩ ﻳﺣﺩﺙ ﺗﻛﺛﻑ ﻋﻠﻰ ﺳﻁﺢ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ،ﻭﺗﺗﺳﺎﻗﻁ ﺍﻟﻣﻳﺎﻩ ﺍﻟﻣﺗﻛﺛﻔﺔ ﻋﻠﻰ ﺍﻷﺭﺽ ﺃﻭ ﻋﻠﻰ ﺍﻷﺷﻳﺎء ﺍﻷﺧﺭﻯ ﺗﺣﺕ ﺍﻟﻭﺣﺩﺓ. ● ﻻ ﺗﺳﺗﺧﺩﻡ ﻫﺫﻩ ﺍﻟﻭﺣﺩﺓ ﻓﻲ ﺃﻱ ﻏﺭﺽ ﺧﻼﻑ ﺍﻟﺗﺑﺭﻳﺩ ﻭﺍﻟﺗﺩﻓﺋﺔ ﻭﺍﻟﺗﺭﻁﻳﺏ ﻭﺗﺩﻭﻳﺭ ﻫﻭﺍء ﺍﻟﻐﺭﻑ ﻓﻲ ﺍﻟﻣﺳﺎﻛﻥ ﺍﻟﻌﺎﺩﻳﺔ. ﺍﻟﺗﻧﻅﻳﻑ ﻭﺍﻟﻌﻧﺎﻳﺔ ﺣﺎﻟﺔ ﺃﻭﻟﻭﻳﺔ ﺍﻟﺗﺑﺭﻳﺩ: ﻋﻧﺩ ﺗﺷﻐﻳﻝ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺍﻷﺧﺭﻯ ﻓﻲ ﻧﻔﺱ ﺍﻟﻧﻅﺎﻡ ﻋﻠﻰ ﻭﺿﻊ ﺑﺎﺭﺩ ﻭﺟﺎﻑ ،ﻻ ﻳﻣﻛﻥ ﺍﺧﺗﻳﺎﺭ ﺍﻟﺗﺩﻓﺋﺔ ﻓﻲ ﻧﻔﺱ ﺍﻟﻭﻗﺕ. ﺣﺎﻟﺔ ﺃﻭﻟﻭﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ: ﻋﻧﺩ ﺗﺷﻐﻳﻝ ﺍﻟﻭﺣﺩﺍﺕ ﺍﻟﺩﺍﺧﻠﻳﺔ ﺍﻷﺧﺭﻯ ﻓﻲ ﻧﻔﺱ ﺍﻟﻧﻅﺎﻡ ﻋﻠﻰ ﻭﺿﻊ ﺍﻟﺗﺩﻓﺋﺔ ،ﻻ ﻳﻣﻛﻥ ﺍﺧﺗﻳﺎﺭ ﻭﺿﻊ ﺑﺎﺭﺩ ﻭﺟﺎﻑ ﻓﻲ ﻧﻔﺱ ﺍﻟﻭﻗﺕ. ﻭﺿﻊ ﺍﻟﺗﺩﻓﺋﺔ ﺗﻧﺑﻳﻪ ● ﻗﺑﻝ ﺗﻧﻅﻳﻑ ﺍﻟﻭﺣﺩﺓ ،ﺗﺄﻛﺩ ﻣﻥ ﺇﻳﻘﺎﻓﻬﺎ ﻭﻓﺻﻝ ﻣﺻﺩﺭ ﺍﻟﻁﺎﻗﺔ. ● ﻻ ﺗﻘﻑ ﻋﻠﻰ ﻣﻧﺻﺔ ﻏﻳﺭ ﺛﺎﺑﺗﺔ ﺃﺛﻧﺎء ﺍﻟﺗﻧﻅﻳﻑ. ● ﻋﻧﺩ ﺇﺯﺍﻟﺔ ﺃﻭ ﺍﺳﺗﺑﺩﺍﻝ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ،ﺗﺄﻛﺩ ﻣﻥ ﻋﺩﻡ ﻟﻣﺱ ﻣﺑﺎﺩﻝ ﺍﻟﺣﺭﺍﺭﺓ ،ﻧﻅﺭً ﺍ ﻷﻧﻪ ﻗﺩ ﺗﺣﺩﺙ ﺇﺻﺎﺑﺔ ﺷﺧﺻﻳﺔ. ● ﺗﺄﻛﺩ ﻣﻥ ﺗﺭﻛﻳﺏ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ ﺑﺷﻛﻝ ﻣﺣﻛﻡ. ● ﻻ ﺗﻘﻡ ﺑﺗﻧﻅﻳﻑ ﺍﻟﻭﺣﺩﺓ ﻣﻥ ﺍﻟﺩﺍﺧﻝ ﺑﻧﻔﺳﻙ .ﻟﻠﺗﻧﻅﻳﻑ ﻣﻥ ﺍﻟﺩﺍﺧﻝ ،ﺍﺣﺭﺹ ﺩﺍﺋﻣًﺎ ﻋﻠﻰ ﺍﺳﺗﺷﺎﺭﺓ ﻣﻭﻅﻑ ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﻣﻌﺗﻣﺩ. ● ﻋﻧﺩ ﺗﻧﻅﻳﻑ ﺟﺳﻡ ﺍﻟﻭﺣﺩﺓ ،ﻻ ﺗﺳﺗﺧﺩﻡ ﻣﻳﺎﻩ ﺳﺎﺧﻧﺔ ﺗﺯﻳﺩ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺗﻬﺎ ﻋﻥ 40ﺩﺭﺟﺔ ﻣﺋﻭﻳﺔ ،ﺃﻭ ﻣﻧﻅﻔﺎﺕ ﻗﻭﻳﺔ ﻛﺎﺷﻁﺔ ،ﺃﻭ ﻋﻭﺍﻣﻝ ﺗﻧﻅﻳﻑ ﻣﺗﻁﺎﻳﺭﺓ ﻣﺛﻝ ﺍﻟﺑﻧﺯﻳﻥ ﺃﻭ ﻣﺭﻗﻕ ﺍﻟﻁﻼء )ﺍﻟﺗﻧﺭ(. ● ﻻ ﺗﻘﻡ ﺑﺈﺯﺍﻟﺔ ﺃﻱ ﺟﺯء ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺑﺎﺳﺗﺛﻧﺎء ﺍﻟﻣﺭﺷﺢ. ● ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺳﻣﺎﺡ ﺑﺗﺭﺍﻛﻡ ﺍﻟﻐﺑﺎﺭ ﻋﻠﻰ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ،ﻓﺳﻭﻑ ﻳﻘﻝ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ،ﻣﻣﺎ ﻳﻘﻠﻝ ﻣﻥ ﻛﻔﺎءﺓ ﺍﻟﺗﺷﻐﻳﻝ ﻭﺯﻳﺎﺩﺓ ﺍﻟﺿﻭﺿﺎء. ● ﺃﺛﻧﺎء ﻓﺗﺭﺍﺕ ﺍﻟﺗﺷﻐﻳﻝ ﺍﻟﻌﺎﺩﻳﺔ ،ﻳﺟﺏ ﺗﻧﻅﻳﻑ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ﻛﻝ 2ﺷﻬﺭ. ﺗﻧﻅﻳﻑ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﻋﻧﺩﻣﺎ ﻳﻭﻣﺽ ﻣﺻﺑﺎﺡ ﺍﻟﻣﺭﺷﺢ ،ﻗﻡ ﺑﺈﺯﺍﻟﺔ ﺍﻟﻣﺭﺷﺢ ﻭﺗﻧﻅﻳﻔﻪ. .1ﺍﺿﻐﻁ ﻋﻠﻰ ﺃﺯﺭﺍﺭ ﺍﻟﺿﻐﻁ ﺍﻟﺧﺎﺻﺔ ﺑﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ )ﻣﻛﺎﻧﻳﻥ( ﻭﺍﻓﺗﺢ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ. .2ﺍﺳﺣﺏ ﺍﻟﻣﺭﺷﺢ ﻟﻠﺧﺎﺭﺝ ﻣﻥ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ. .1 .2 Ar-3 25/4/2017 PM 1:06:26 9369313226-02_OM_AR.indd 3 .3ﻗﻡ ﺑﺗﻧﻅﻳﻑ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء. ﻗﻡ ﺑﺈﺯﺍﻟﺔ ﺍﻟﻐﺑﺎﺭ ﻣﻥ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ﺑﺎﺳﺗﺧﺩﺍﻡ ﻣﻛﻧﺳﺔ ﺃﻭ ﻋﻥ ﻁﺭﻳﻕ ﻏﺳﻠﻬﺎ .ﻭﺑﻌﺩ ﺍﻟﻐﺳﻝ ،ﺍﺗﺭﻙ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ﺗﺟﻑ ﺑﺎﻟﻛﺎﻣﻝ ﻓﻲ ﻣﻧﻁﻘﺔ ﻣﺣﻣﻳﺔ ﻣﻥ ﺿﻭء ﺍﻟﺷﻣﺱ. • ﻳﻣﻛﻥ ﺗﻧﻅﻳﻑ ﺍﻟﻐﺑﺎﺭ ﻣﻥ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﺇﻣﺎ ﺑﺎﺳﺗﺧﺩﺍﻡ ﻣﻛﻧﺳﺔ ﻛﻬﺭﺑﺎﺋﻳﺔ ،ﺃﻭ ﻏﺳﻝ ﺍﻟﻣﺭﺷﺢ ﻓﻲ ﻣﺣﻠﻭﻝ ﻣﻧﻅﻑ ﻣﻌﺗﺩﻝ ﻭﻣﺎء ﺩﺍﻓﺊ .ﻓﻲ ﺣﺎﻟﺔ ﻏﺳﻝ ﺍﻟﻣﺭﺷﺢ ،ﺗﺄﻛﺩ ﻣﻥ ﺗﺭﻛﻪ ﻳﺟﻑ ﺑﺎﻟﻛﺎﻣﻝ ﻓﻲ ﻣﻛﺎﻥ ﻣﻅﻠﻝ ﻗﺑﻝ ﺇﻋﺎﺩﺓ ﺍﻟﺗﺭﻛﻳﺏ. • ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺳﻣﺎﺡ ﺑﺗﺭﺍﻛﻡ ﺍﻟﻐﺑﺎﺭ ﻋﻠﻰ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ،ﻓﺳﻭﻑ ﻳﻘﻝ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ،ﻣﻣﺎ ﻳﻘﻠﻝ ﻣﻥ ﻛﻔﺎءﺓ ﺍﻟﺗﺷﻐﻳﻝ ﻭﺯﻳﺎﺩﺓ ﺍﻟﺿﻭﺿﺎء. .4ﺃﻋﺩ ﺗﺭﻛﻳﺏ ﻣﺭﺷﺣﺎﺕ ﺍﻟﻬﻭﺍء ﻓﻲ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ. ) (1ﺃﻋﺩ ﺗﺭﻛﻳﺏ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﻓﻲ ﺍﻟﺣﺎﻣﻝ ﺍﻟﺧﺎﺹ ﺑﻪ. ) (2ﺗﺄﻛﺩ ﻣﻥ ﺃﻥ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﻳﻼﻣﺱ ﺳﺩﺍﺩﺓ ﺍﻟﻣﺭﺷﺢ ﻋﻧﺩ ﺇﻋﺎﺩﺓ ﻭﺿﻌﻪ ﻓﻲ ﺣﺎﻣﻠﻪ. .5ﺃﻏﻠﻕ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ ﺛﻡ ﺍﺩﻓﻊ ﺧﻁﺎﻓﺎﺕ ﺷﺑﻛﺔ ﺍﻻﻣﺗﺻﺎﺹ ﻟﻠﺧﺎﺭﺝ. ● ﻗﺩ ﺗﻌﻣﻝ ﺍﻟﻣﺭﻭﺣﺔ ﺑﺳﺭﻋﺔ ﻣﻧﺧﻔﺿﺔ ﺃﺛﻧﺎء ﺗﺷﻐﻳﻝ ﻭﺿﻊ ﺟﺎﻑ ﺃﻭ ﻋﻧﺩ ﻣﺭﺍﻗﺑﺔ ﺍﻟﻭﺣﺩﺓ ﻟﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺍﻟﻐﺭﻓﺔ. ● ﻓﻲ ﻭﺿﻊ ﻋﻣﻠﻳﺔ ﺍﻟﻣﺭﺍﻗﺑﺔ ﺍﻟﺗﻠﻘﺎﺋﻲ ،ﺗﻌﻣﻝ ﺍﻟﻣﺭﻭﺣﺔ ﺑﺳﺭﻋﺔ ﻣﻧﺧﻔﺿﺔ. ﺍﻟﻣﺻﺎﺑﻳﺢ ﺍﻟﻭﺍﻣﺿﺔ: ● ﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ(: ﻳﺟﺭﻱ ﺗﻧﻔﻳﺫ ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ) .ﺭﺍﺟﻊ ﺻﻔﺣﺔ (2 ● ﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ(: ﻳﺟﺭﻱ ﺗﻧﻔﻳﺫ ﻋﻣﻠﻳﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ) .ﺭﺍﺟﻊ ﺻﻔﺣﺔ (2 ● ﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( ﻭﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺅﻗﺕ )ﺍﻟﺑﺭﺗﻘﺎﻟﻲ( ﺑﺎﻟﺗﺑﺎﺩﻝ: ﺗﻡ ﺍﻻﺳﺗﺭﺩﺍﺩ ﻣﻥ ﺍﻧﻘﻁﺎﻉ ﺍﻟﺗﻳﺎﺭ. ● ﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( ﻭﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺅﻗﺕ )ﺍﻟﺑﺭﺗﻘﺎﻟﻲ( ﻓﻲ ﺁﻥ ﻭﺍﺣﺩ: ﻳﺗﻡ ﺍﻟﺗﺷﻐﻳﻝ ﻓﻲ ﺍﻟﻭﺿﻊ ﺍﻟﺗﺟﺭﻳﺑﻲ .ﺍﺳﺄﻝ ﺍﻟﻣﺩﻳﺭ ﻓﻘﺩ ﺗﻛﻭﻥ ﻫﻧﺎﻙ ﺻﻳﺎﻧﺔ ﻗﻳﺩ ﺍﻟﺗﻧﻔﻳﺫ. ● ﺇﺿﺎءﺓ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﺗﺷﻐﻳﻝ )ﺍﻷﺧﺿﺭ( ﻭﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺅﻗﺕ )ﺍﻟﺑﺭﺗﻘﺎﻟﻲ(: ﻫﺫﻩ ﻫﻲ ﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ) .ﺭﺍﺟﻊ ﺻﻔﺣﺔ (2 ﺳﻣﺎﻉ ﺿﻭﺿﺎء: ● ﻓﻲ ﺍﻷﺣﻭﺍﻝ ﺍﻟﺗﺎﻟﻳﺔ ﺗﻅﻬﺭ ﺃﺻﻭﺍﺕ ﺗﺩﻓﻕ ﺍﻟﻣﻳﺎﻩ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻭﻳﺻﺑﺢ ﺻﻭﺕ ﺍﻟﺗﺷﻐﻳﻝ ﻣﺭﺗﻔﻊ .ﺗﻭﺟﺩ ﺃﺻﻭﺍﺕ ﻟﺗﺩﻓﻕ ﺳﺎﺋﻝ ﺍﻟﺗﺑﺭﻳﺩ. ﻋﻧﺩ ﺑﺩء ﺍﻟﻌﻣﻠﻳﺔ ﻋﻧﺩ ﺍﻧﺗﻬﺎء ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ ﻋﻧﺩ ﺍﻧﺗﻬﺎء ﻋﻣﻠﻳﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ ● ﺃﺛﻧﺎء ﺍﻟﺗﺷﻐﻳﻝ ،ﻗﺩ ﻳﻅﻬﺭ ﺻﻭﺕ ﺻﺭﻳﺭ ﻁﻔﻳﻑ .ﻭﻫﺫﺍ ﻳﻧﺗﺞ ﻋﻥ ﺍﻟﺗﻣﺩﺩ ﻭﺍﻻﻧﻛﻣﺎﺵ ﺍﻟﻠﺣﻅﻲ ﻟﻠﻭﺣﺔ ﺑﺳﺑﺏ ﺍﻟﺗﻐﻳﻳﺭﺍﺕ ﻓﻲ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ. ● ﻳﻣﻛﻥ ﺗﻧﻅﻳﻑ ﺍﻟﻐﺑﺎﺭ ﻣﻥ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﺇﻣﺎ ﺑﺎﺳﺗﺧﺩﺍﻡ ﻣﻛﻧﺳﺔ ﻛﻬﺭﺑﺎﺋﻳﺔ ،ﺃﻭ ﻏﺳﻝ ﺍﻟﻣﺭﺷﺢ ﻓﻲ ﻣﺣﻠﻭﻝ ﻣﻧﻅﻑ ﻣﻌﺗﺩﻝ ﻭﻣﺎء ﺩﺍﻓﺊ .ﻓﻲ ﺣﺎﻟﺔ ﻏﺳﻝ ﺍﻟﻣﺭﺷﺢ ،ﺗﺄﻛﺩ ﻣﻥ ﺗﺭﻛﻪ ﻳﺟﻑ ﺑﺎﻟﻛﺎﻣﻝ ﻓﻲ ﻣﻛﺎﻥ ﻣﻅﻠﻝ ﻗﺑﻝ ﺇﻋﺎﺩﺓ ﺍﻟﺗﺭﻛﻳﺏ. ● ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺳﻣﺎﺡ ﺑﺗﺭﺍﻛﻡ ﺍﻟﻐﺑﺎﺭ ﻋﻠﻰ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ،ﻓﺳﻭﻑ ﻳﻘﻝ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ،ﻣﻣﺎ ﻳﻘﻠﻝ ﻣﻥ ﻛﻔﺎءﺓ ﺍﻟﺗﺷﻐﻳﻝ ﻭﺯﻳﺎﺩﺓ ﺍﻟﺿﻭﺿﺎء. ● ﺑﻌﺩ ﺗﺷﻐﻳﻝ ﺍﻟﻁﺎﻗﺔ ،ﺍﺿﻐﻁ ﺯﺭ ﺍﻟﻣﺭﺷﺢ ﻋﻠﻰ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﻹﻳﻘﺎﻑ ﺗﺷﻐﻳﻝ ﻣﺻﺑﺎﺡ ﺍﻟﻣﺭﺷﺢ. )ﺭﺍﺟﻊ ﺩﻟﻳﻝ ﺍﻟﺗﺷﻐﻳﻝ ﺍﻟﻣﺭﻓﻕ ﻣﻊ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﻟﻠﺣﺻﻭﻝ ﻋﻠﻰ ﺗﻔﺎﺻﻳﻝ(. ﺗﻧﻅﻳﻑ ﺍﻟﺟﺳﻡ ﻗﻡ ﺑﻐﺳﻝ ﺍﻟﺟﺳﻡ ﺑﻣﺎء ﺩﺍﻓﺊ ،ﺛﻡ ﻗﻡ ﺑﺗﺟﻔﻳﻔﻪ ﺑﻘﻁﻌﺔ ﻗﻣﺎﺵ ﻧﻅﻳﻔﺔ ﻭﻧﺎﻋﻣﺔ. ﻋﻧﺩ ﻋﺩﻡ ﺍﻻﺳﺗﺧﺩﺍﻡ ﻟﻔﺗﺭﺓ ﻁﻭﻳﻠﺔ ﺍﺗﺭﻙ ﺍﻟﻘﺎﻁﻊ ﻗﻳﺩ ﺍﻟﺗﺷﻐﻳﻝ ﻟﻣﺩﺓ 12ﺳﺎﻋﺔ ﻋﻠﻰ ﺍﻷﻗﻝ ﻗﺑﻝ ﺑﺩء ﺍﻟﺗﺷﻐﻳﻝ ﻋﻧﺩ ﺍﻟﺭﻏﺑﺔ ﻓﻲ ﺍﺳﺗﺧﺩﺍﻡ ﺍﻟﻭﺣﺩﺓ ﻣﺭﺓ ﺃﺧﺭﻯ. ﺍﺳﺗﻛﺷﺎﻑ ﺍﻷﻋﻁﺎﻝ ﻭﺇﺻﻼﺣﻬﺎ ﺍﻷﺣﻭﺍﻝ ﺍﻟﺗﺎﻟﻳﺔ ﻻ ﺗﻣﺛﻝ ﺃﻋﻁﺎﻻ ﺃﻭ ﺇﺧﻔﺎ ًﻗﺎ ﻓﻲ ﺍﻟﺗﺷﻐﻳﻝ. ● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ ،ﻗﺩ ﻳﺗﻡ ﺳﻣﺎﻉ ﺻﻭﺕ ﻫﺳﻳﺱ ﻓﻲ ﺑﻌﺽ ﺍﻷﺣﻳﺎﻥ .ﻳﻧﺗﺞ ﻫﺫﺍ ﺍﻟﺻﻭﺕ ﻋﻥ ﻋﻣﻠﻳﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ) .ﺭﺍﺟﻊ ﺻﻔﺣﺔ (2 ﺍﻟﺭﻭﺍﺋﺢ: ● ﻗﺩ ﺗﻧﺑﻌﺙ ﺑﻌﺽ ﺍﻟﺭﻭﺍﺋﺢ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ .ﻫﺫﻩ ﺍﻟﺭﺍﺋﺣﺔ ﺗﻛﻭﻥ ﻧﺎﺗﺟﺔ ﻋﻥ ﺍﻟﺭﻭﺍﺋﺢ ﻓﻲ ﺍﻟﻐﺭﻓﺔ )ﻣﺛﻝ ﺭﻭﺍﺋﺢ ﺍﻟﻔﺎﻛﻬﺔ ﺃﻭ ﺍﻟﺗﺑﻎ ﺃﻭ ﻏﻳﺭﻩ( ﻭﺍﻟﺗﻲ ﻳﺗﻡ ﺍﻣﺗﺻﺎﺻﻬﺎ ﻓﻲ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء. ﺧﺭﻭﺝ ﺿﺑﺎﺏ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ: ● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺑﺭﻳﺩ ،ﻗﺩ ﺗﺗﻡ ﻣﺷﺎﻫﺩﺓ ﺿﺑﺎﺏ ﺭﻓﻳﻊ ﻳﻧﺑﻌﺙ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ .ﻳﻧﺗﺞ ﻫﺫﺍ ﺍﻷﻣﺭ ﺑﺳﺑﺏ ﺍﻟﺗﺑﺭﻳﺩ ﺍﻟﻣﻔﺎﺟﺊ ﻟﻬﻭﺍء ﺍﻟﻐﺭﻓﺔ ﺑﻭﺍﺳﻁﺔ ﺍﻟﻬﻭﺍء ﺍﻟﻣﻧﺑﻌﺙ ﻣﻥ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ،ﻣﻣﺎ ﻳﺅﺩﻱ ﺇﻟﻰ ﺍﻟﺗﻛﺛﻳﻑ ﻭﺗﻛﻭﻥ ﺍﻟﺿﺑﺎﺏ. ﺧﺭﻭﺝ ﺑﺧﺎﺭ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ: ● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ ،ﻗﺩ ﺗﺗﻭﻗﻑ ﻣﺭﻭﺣﺔ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ ،ﻭﻗﺩ ﺗﺗﻡ ﻣﺷﺎﻫﺩﺓ ﺑﺧﺎﺭ ﻳﺗﺻﺎﻋﺩ ﻣﻥ ﺍﻟﻭﺣﺩﺓ. ﻭﻫﺫﺍ ﻳﻧﺷﺄ ﺑﺳﺑﺏ ﻋﻣﻠﻳﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ) .ﺭﺍﺟﻊ ﺻﻔﺣﺔ (2 ﺇﺧﺭﺍﺝ ﻣﺎء ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ: ● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ ،ﻗﺩ ﻳﺧﺭﺝ ﻣﺎء ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ ﺑﺳﺑﺏ ﻋﻣﻠﻳﺔ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ. ﺍﻷﺣﻭﺍﻝ ﺍﻟﺗﺎﻟﻳﺔ ﻗﺩ ﻻ ﺗﻛﻭﻥ ﺃﻋﻁﺎﻝ ﻟﺫﺍ ﻗﻡ ﺑﺎﻟﻔﺣﺹ ﻣﺭﺓ ﺃﺧﺭﻯ. ﻋﺩﻡ ﺍﻟﺗﺷﻐﻳﻝ ﻣﻁﻠ ًﻘﺎ: ● ﻫﻝ ﻛﺎﻥ ﻫﻧﺎﻙ ﺍﻧﻘﻁﺎﻉ ﻓﻲ ﺍﻟﻁﺎﻗﺔ؟ ● ﻫﻝ ﺗﻠﻑ ﺍﻟﻣﺻﻬﺭ ،ﺃﻭ ﺗﻡ ﺗﻌﻁﻳﻝ ﻗﺎﻁﻊ ﺍﻟﺩﺍﺋﺭﺓ؟ ● ﻫﻝ ﺗﻡ ﺇﻋﺩﺍﺩ ﻣﻔﺗﺎﺡ ﺍﻟﻁﺎﻗﺔ ﺍﻟﺭﺋﻳﺳﻲ ﻋﻠﻰ ﻭﺿﻊ ﺇﻳﻘﺎﻑ ﺍﻟﺗﺷﻐﻳﻝ؟ ● ﻫﻝ ﺗﺣﺎﻭﻝ ﺍﻟﺗﺷﻐﻳﻝ ﻓﻲ ﻭﺿﻊ ﻣﺧﺗﻠﻑ ﻋﻥ ﺣﺎﻟﺔ ﺍﻷﻭﻟﻭﻳﺔ؟ )ﺭﺍﺟﻊ ﺻﻔﺣﺔ (3 ﺗﻌﺫﺭ ﺍﻟﺗﺷﻐﻳﻝ ﻣﺑﺎﺷﺭﺓ: ● ﻓﻲ ﺣﺎﻟﺔ ﺇﻳﻘﺎﻑ ﺍﻟﻭﺣﺩﺓ ﺛﻡ ﺗﺷﻐﻳﻠﻬﺎ ﻣﺭﺓ ﺃﺧﺭﻯ ﻋﻠﻰ ﺍﻟﻔﻭﺭ ،ﻟﻥ ﻳﻌﻣﻝ ﺍﻟﺿﺎﻏﻁ ﻟﻣﺩﺓ 3ﺩﻗﺎﺋﻕ ﺗﻘﺭﻳﺑًﺎ ،ﻣﻥ ﺃﺟﻝ ﻣﻧﻊ ﺗﻠﻑ ﺍﻟﻣﺻﻬﺭ. ● ﻫﻝ ﻋﻣﻠﻳﺔ ﺇﻳﻘﺎﻑ ﺍﻟﺗﺷﻐﻳﻝ ﺍﻟﺗﻠﻘﺎﺋﻲ ﻹﻋﺩﺍﺩ ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ ﻧﺷﻁﺔ؟ )ﺭﺍﺟﻊ ﺻﻔﺣﺔ (2 ● ﻓﻲ ﺣﺎﻟﺔ ﻓﺻﻝ ﺍﻟﻘﺎﻁﻊ ﺍﻟﻛﻬﺭﺑﺎﺋﻲ ﺛﻡ ﺗﻭﺻﻳﻠﻪ ﻣﺭﺓ ﺃﺧﺭﻯ ،ﻓﺳﻭﻑ ﺗﻌﻣﻝ ﺩﺍﺋﺭﺓ ﺍﻟﺣﻣﺎﻳﺔ ﻟﻣﺩﺓ 3ﺗﻘﺭﻳﺑًﺎ، ﺑﺣﻳﺙ ﺗﻣﻧﻊ ﺗﺷﻐﻳﻝ ﺍﻟﻭﺣﺩﺓ ﺧﻼﻝ ﻫﺫﻩ ﺍﻟﻔﺗﺭﺓ. ﺗﻌﺫﺭ ﺗﻐﻳﻳﺭ ﻭﺿﻊ ﺍﻟﺗﺷﻐﻳﻝ: ● ﻫﻝ ﺗﺣﺎﻭﻝ ﺗﻐﻳﻳﺭ ﺍﻟﺗﺷﻐﻳﻝ ﺇﻟﻰ ﻭﺿﻊ ﻣﺧﺗﻠﻑ ﻋﻥ ﺍﻷﺣﻭﺍﻝ ﺫﺍﺕ ﺍﻷﻭﻟﻭﻳﺔ؟ )ﺭﺍﺟﻊ ﺻﻔﺣﺔ (3 ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ﺿﻌﻳﻑ ﺃﻭ ﻳﺗﻭﻗﻑ: ● ﻋﻧﺩ ﺑﺩء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ ،ﻗﺩ ﺗﺗﻭﻗﻑ ﻣﺭﻭﺣﺔ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻣﺅﻗ ًﺗﺎ ﻟﻠﺳﻣﺎﺡ ﺑﺗﺳﺧﻳﻥ ﺍﻷﺟﺯﺍء ﺍﻟﺩﺍﺧﻠﻳﺔ. ﺿﻌﻑ ﺃﺩﺍء ﺍﻟﺗﺑﺭﻳﺩ )ﺃﻭ ﺍﻟﺗﺩﻓﺋﺔ(: ● ﻫﻝ ﻗﻣﺕ ﺑﺿﺑﻁ ﺇﻋﺩﺍﺩﺍﺕ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺍﻟﻐﺭﻓﺔ ﺑﺷﻛﻝ ﺻﺣﻳﺢ )ﻣﻧﻅﻣﺔ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ(؟ ● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ ،ﺇﺫﺍ ﺍﺭﺗﻔﻌﺕ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺍﻟﻐﺭﻓﺔ ﺃﻋﻠﻰ ﻣﻥ ﺇﻋﺩﺍﺩ ﻣﻧﻅﻡ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ،ﻓﺳﻭﻑ ﺗﺗﻭﻗﻑ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ ،ﻭﺗﺗﻭﻗﻑ ﻣﺭﻭﺣﺔ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ .ﺇﺫﺍ ﺃﺭﺩﺕ ﺗﺩﻓﺋﺔ ﺍﻟﻐﺭﻓﺔ ﺑﺷﻛﻝ ﺇﺿﺎﻓﻲ ،ﻗﻡ ﺑﺿﺑﻁ ﻣﻧﻅﻡ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻋﻠﻰ ﺇﻋﺩﺍﺩ ﺃﻋﻠﻰ. ● ﻫﻝ ﻣﺭﺷﺢ ﺍﻟﻬﻭﺍء ﻣﺗﺳﺦ؟ )ﺭﺍﺟﻊ ﺻﻔﺣﺔ (3 ● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﺳﺗﺭﺩﺍﺩ ﺍﻟﺯﻳﺕ ،ﻗﺩ ﻳﺗﻭﻗﻑ ﺗﺩﻓﻕ ﺍﻟﻬﻭﺍء ﻟﻣﺩﺓ 10ﺩﻗﺎﺋﻕ ﺗﻘﺭﻳﺑًﺎ) .ﺭﺍﺟﻊ ﺻﻔﺣﺔ (2 ● ﺃﺛﻧﺎء ﻋﻣﻠﻳﺔ ﺍﻟﺗﺩﻓﺋﺔ ،ﺗﺗﻭﻗﻑ ﺍﻟﻭﺣﺩﺓ ﻋﻥ ﺍﻟﺗﺷﻐﻳﻝ ﻣﺅﻗ ًﺗﺎ )ﻣﺎ ﺑﻳﻥ 4ﻭ 15ﺩﻗﻳﻘﺔ( ﻧﻅﺭً ﺍ ﻟﺗﺷﻐﻳﻝ ﻭﺿﻊ ﺇﺫﺍﺑﺔ ﺍﻟﺻﻘﻳﻊ ﺃﻭﺗﻭﻣﺎﺗﻳﻛﻳًﺎ) .ﺭﺍﺟﻊ ﺻﻔﺣﺔ (2 ● ﻫﻝ ﺍﻟﻭﺣﺩﺓ ﻓﻲ ﺣﺎﻟﺔ ﺍﻻﺳﺗﻌﺩﺍﺩ؟ )ﺭﺍﺟﻊ ﺻﻔﺣﺔ (3 ● ﻫﻝ ﻣﻧﻔﺫ ﺍﻹﺩﺧﺎﻝ ﺃﻭ ﻣﻧﻔﺫ ﺍﻹﺧﺭﺍﺝ ﻓﻲ ﺗﻛﻳﻳﻑ ﺍﻟﻬﻭﺍء ﻣﺳﺩﻭﺩ؟ ● ﻫﻝ ﻫﻧﺎﻙ ﻧﺎﻓﺫﺓ ﺃﻭ ﺑﺎﺏ ﻣﻔﺗﻭﺡ؟ ● ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺗﺑﺭﻳﺩ ،ﻫﻝ ﻫﻧﺎﻙ ﻧﺎﻓﺫﺓ ﺗﺳﻣﺢ ﺑﺩﺧﻭﻝ ﺿﻭء ﺷﻣﺱ ﺳﺎﻁﻊ؟ )ﺃﻏﻠﻕ ﺍﻟﺳﺗﺎﺋﺭ(. Ar-4 25/4/2017 PM 1:06:26 9369313226-02_OM_AR.indd 4 ● ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺗﺑﺭﻳﺩ ،ﻫﻝ ﻫﻧﺎﻙ ﺟﻬﺎﺯ ﺗﺳﺧﻳﻥ ﺃﻭ ﺃﺟﻬﺯﺓ ﻛﻣﺑﻳﻭﺗﺭ ﺩﺍﺧﻝ ﺍﻟﻐﺭﻓﺔ ،ﺃﻭ ﻫﻝ ﻳﻭﺟﺩ ﻋﺩﺩ ﻛﺑﻳﺭ ﻣﻥ ﺍﻷﺷﺧﺎﺹ ﻓﻲ ﺍﻟﻐﺭﻓﺔ؟ ﺍﻟﻣﻭﺍﺻﻔﺎﺕ ● ﻫﻝ ﺗﻡ ﺿﺑﻁ ﺳﺭﻋﺔ ﺍﻟﻣﺭﻭﺣﺔ ﻋﻠﻰ ﺇﻋﺩﺍﺩ ﻣﻧﺧﻔﺽ؟ ● ﻫﻝ ﻋﻣﻠﻳﺔ ﺍﻟﺣﻔﻅ ﺍﻟﺗﻠﻘﺎﺋﻲ ﻹﻋﺩﺍﺩ ﺍﻟﻣﺳﺗﺷﻌﺭ ﺍﻟﺑﺷﺭﻱ ﻧﺷﻁﺔ؟ )ﺭﺍﺟﻊ ﺻﻔﺣﺔ (2 ﺍﻟﻁﺭﺍﺯ ﺿﺑﻁ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻋﻠﻰ ﺩﺭﺟﺔ ﺃﻗﻝ ﻣﻥ ﺣﺭﺍﺭﺓ ﺍﻟﻐﺭﻓﺔ ﻭﺍﺳﺗﺧﺩﺍﻣﻬﺎ: ● ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﻻ ﺗﻧﺧﻔﺽ ﺟﻳ ًﺩﺍ .ﻗﺩ ﻻ ﺗﻧﺧﻔﺽ ﺩﺭﺟﺔ ﺍﻟﺣﺭﺍﺭﺓ ﺗﺑﻌًﺎ ﻷﺣﻭﺍﻝ ﺍﻟﻐﺭﻓﺔ) .ﺣﻳﻧﻣﺎ ﺗﻛﻭﻥ ﺍﻟﺭﻁﻭﺑﺔ ﻣﺭﺗﻔﻌﺔ ﺃﻭ ﺩﺭﺟﺔ ﺣﺭﺍﺭﺓ ﺍﻟﻐﺭﻓﺔ ﻣﺭﺗﻔﻌﺔ() .ﺭﺍﺟﻊ ﺻﻔﺣﺔ (3 ﻣﺻﺩﺭ ﺍﻟﻁﺎﻗﺔ AUXK AUXK AUXM AUXM AUXM 024GLAH 018GLAH 030GLAH 024GLAH 018GLAH 240-220ﻓﻭﻟﺕ ﻓﻭﻟﺕ ~ 50ﻫﺭﺗﺯ 230 ،ﻓﻭﻟﺕ ﻓﻭﻟﺕ ~ 60ﻫﺭﺗﺯ ﻣﺩﻯ ﻓﺭﻕ ﺍﻟﺟﻬﺩ ﺍﻟﻣﺗﺎﺡ 198ﺇﻟﻰ 264ﻓﻭﻟﺕ ) 50ﻫﺭﺗﺯ( 198 ،ﺇﻟﻰ 253ﻓﻭﻟﺕ ) 60ﻫﺭﺗﺯ( ﻓﻲ ﺍﻟﻣﻭﺍﻗﻑ ﺍﻟﺗﺎﻟﻳﺔ ﺃﻭﻗﻑ ﺍﻟﺗﺷﻐﻳﻝ ﻋﻠﻰ ﺍﻟﻔﻭﺭ ﻭﺍﺗﺻﻝ ﻣﻊ ﻣﻭﻅﻔﻲ ﺍﻟﺻﻳﺎﻧﺔ ﺍﻟﻣﻌﺗﻣﺩﻳﻥ. ]ﺑﺎﻟﻛﻳﻠﻭ ﻭﺍﺕ[ ﻗﺩﺭﺓ ﺍﻟﺗﺑﺭﻳﺩ ]ﻭﺣﺩﺓ ﺣﺭﺍﺭﻳﺔ ﺑﺭﻳﻁﺎﻧﻳﺔ/ﺳﺎﻋﺔ[ ]ﺑﺎﻟﻛﻳﻠﻭ ﻭﺍﺕ[ ﻗﺩﺭﺓ ﺍﻟﺗﺩﻓﺋﺔ ]ﻭﺣﺩﺓ ﺣﺭﺍﺭﻳﺔ ﺑﺭﻳﻁﺎﻧﻳﺔ/ﺳﺎﻋﺔ[ ● ﺗﻌﺫﺭ ﺣﻝ ﺍﻟﻣﺷﻛﻠﺔ ﺣﺗﻰ ﻓﻲ ﺣﺎﻟﺔ ﺗﻧﻔﻳﺫ ﻓﺣﻭﺻﺎﺕ ﺍﺳﺗﻛﺷﺎﻑ ﺍﻷﺧﻁﺎء ﻭﺇﺻﻼﺣﻬﺎ. ● ﻭﻣﻳﺽ ﻣﺻﺑﺎﺡ ﻣﺅﺷﺭ ﺍﻟﻣﺭﺷﺢ )ﺍﻷﺣﻣﺭ( ﺑﺳﺭﻋﺔ ﺷﺩﻳﺩﺓ. ● ﻅﻬﻭﺭ ﻋﻼﻣﺔ Erﻋﻠﻰ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺳﻠﻛﻳﺔ ﺃﻭ ﻭﺣﺩﺓ ﺍﻟﺗﺣﻛﻡ ﻋﻥ ﺑﻌﺩ ﺍﻟﺑﺳﻳﻁﺔ )ﻋﻥ ﺍﻟﺗﻭﺻﻳﻝ(. ● ﺷﻡ ﺭﺍﺋﺣﺔ ﺣﺭﻳﻕ. ]ﻭﺍﺕ[ ﻁﺎﻗﺔ ﺍﻹﺩﺧﺎﻝ ][A ﺍﻟﺗﻳﺎﺭ 5.6 9.0 7.1 7.1 5.6 19,100 24,200 30,700 19,100 24,200 6.3 8.0 10.0 6.3 8.0 21,500 27,300 34,100 21,500 27,300 20 25 49 40 40 0.20 0.24 0.41 0.34 0.34 ﻣﺳﺗﻭﻯ ﺍﻟﺿﻐﻁ ﺍﻟﺻﻭﺗﻲ ﻣﺭﺗﻔﻊ ﺩﻳﺳﻳﺑﻝ ][A 33 35 40 38 38 ﻣﺗﻭﺳﻁ -ﻣﺭﺗﻔﻊ ﺩﻳﺳﻳﺑﻝ ][A 32 33 36 37 37 ﻣﺗﻭﺳﻁ ﺩﻳﺳﻳﺑﻝ ][A 31 32 34 36 36 ﻣﺗﻭﺳﻁ -ﻣﻧﺧﻔﺽ ﺩﻳﺳﻳﺑﻝ ][A 30 31 32 35 35 ﻣﻧﺧﻔﺽ ﺩﻳﺳﻳﺑﻝ ][A 29 30 31 34 34 ﻫﺎﺩﺉ ﺩﻳﺳﻳﺑﻝ ][A 28 28 28 33 33 ﺍﻷﺑﻌﺎﺩ ﻭﺍﻟﻭﺯﻥ 246 ﺍﻻﺭﺗﻔﺎﻉ ]ﻣﻡ[ ﺍﻟﻌﺭﺽ ]ﻣﻡ[ 840 ﺍﻟﻌﻣﻕ ]ﻣﻡ[ 840 ﺍﻟﻭﺯﻥ ]ﻛﺟﻡ[ 24 288 26.5 24.5 ﻣﺻﺩﺭ ﺍﻟﻁﺎﻗﺔ AUXK AUXK AUXK AUXK AUXK 054GLAH 045GLAH 036GLAH 034GLAH 030GLAH 240-220ﻓﻭﻟﺕ ﻓﻭﻟﺕ ~ 50ﻫﺭﺗﺯ 230 ،ﻓﻭﻟﺕ ﻓﻭﻟﺕ ~ 60ﻫﺭﺗﺯ ﻣﺩﻯ ﻓﺭﻕ ﺍﻟﺟﻬﺩ ﺍﻟﻣﺗﺎﺡ 198ﺇﻟﻰ 264ﻓﻭﻟﺕ ) 50ﻫﺭﺗﺯ( 198 ،ﺇﻟﻰ 253ﻓﻭﻟﺕ ) 60ﻫﺭﺗﺯ( ﺍﻟﻁﺭﺍﺯ ﻗﺩﺭﺓ ﺍﻟﺗﺑﺭﻳﺩ ]ﺑﺎﻟﻛﻳﻠﻭ ﻭﺍﺕ[ ]ﻭﺣﺩﺓ ﺣﺭﺍﺭﻳﺔ ﺑﺭﻳﻁﺎﻧﻳﺔ/ﺳﺎﻋﺔ[ ]ﺑﺎﻟﻛﻳﻠﻭ ﻭﺍﺕ[ 9.0 10.0 11.2 12.5 14.0 30,700 34,100 38,200 42,700 47,800 10.0 11.2 12.5 14.0 16.0 ﻗﺩﺭﺓ ﺍﻟﺗﺩﻓﺋﺔ ]ﻭﺣﺩﺓ ﺣﺭﺍﺭﻳﺔ ﺑﺭﻳﻁﺎﻧﻳﺔ/ﺳﺎﻋﺔ[ 116 89 61 47 47 ]ﻭﺍﺕ[ ﻁﺎﻗﺔ ﺍﻹﺩﺧﺎﻝ 0.86 0.67 0.47 0.38 0.38 ][A ﺍﻟﺗﻳﺎﺭ ﻣﺳﺗﻭﻯ ﺍﻟﺿﻐﻁ ﺍﻟﺻﻭﺗﻲ 47 44 41 39 39 ﺩﻳﺳﻳﺑﻝ ][A ﻣﺭﺗﻔﻊ 45 42 40 38 38 ﺩﻳﺳﻳﺑﻝ ][A ﻣﺗﻭﺳﻁ -ﻣﺭﺗﻔﻊ 42 40 38 37 37 ﺩﻳﺳﻳﺑﻝ ][A ﻣﺗﻭﺳﻁ 39 38 37 36 36 ﺩﻳﺳﻳﺑﻝ ][A ﻣﺗﻭﺳﻁ -ﻣﻧﺧﻔﺽ 36 36 35 35 35 ﺩﻳﺳﻳﺑﻝ ][A ﻣﻧﺧﻔﺽ 33 33 33 33 33 ﺩﻳﺳﻳﺑﻝ ][A ﻫﺎﺩﺉ ﺍﻷﺑﻌﺎﺩ ﻭﺍﻟﻭﺯﻥ 288 ]ﻣﻡ[ ﺍﻻﺭﺗﻔﺎﻉ 840 ]ﻣﻡ[ ﺍﻟﻌﺭﺽ 840 ]ﻣﻡ[ ﺍﻟﻌﻣﻕ 29.5 ]ﻛﺟﻡ[ ﺍﻟﻭﺯﻥ ● ﻣﻌﻠﻭﻣﺎﺕ ﺍﻟﺿﻭﺿﺎء ﺍﻟﻣﺳﻣﻭﻋﺔ: ﻳﻛﻭﻥ ﺍﻟﺣﺩ ﺍﻷﻗﺻﻰ ﻟﻣﺳﺗﻭﻯ ﺍﻟﺿﻐﻁ ﺍﻟﺻﻭﺗﻲ ﺃﻗﻝ ﻣﻥ 70ﺩﻳﺳﻳﺑﻝ ) (Aﻟﻛﻝ ﻣﻥ ﺍﻟﻭﺣﺩﺓ ﺍﻟﺩﺍﺧﻠﻳﺔ ﻭﺍﻟﻭﺣﺩﺓ ﺍﻟﺧﺎﺭﺟﻳﺔ .ﺗﺑﻌًﺎ ﻟﻣﻌﻳﺎﺭ 1-IEC 704ﻭ.ISO 3744 34,100 38,200 42,700 47,800 54,600 ● ﻳﺣﺗﻭﻱ ﻫﺫﺍ ﺍﻟﻣﻧﺗﺞ ﻋﻠﻰ ﻏﺎﺯﺍﺕ ﺩﻓﻳﺋﺔ ﻣﻌﺎﻟﺟﺔ ﺑﺎﻟﻔﻠﻭﺭ. Ar-5 25/4/2017 PM 1:06:26 9369313226-02_OM_AR.indd 5 9369313226-02_OM_AR.indd 6 25/4/2017 PM 1:06:26 9369313226-02_OM_AR.indd 7 25/4/2017 PM 1:06:06
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project