Conrad energy 476 A Non-standard battery 476 A Alkali-manganese 6 V 145 mAh 1 pc(s) Data sheet

Conrad energy 476 A Non-standard battery 476 A Alkali-manganese 6 V 145 mAh 1 pc(s) Data sheet
4LR44
TECHNICAL SPECIFICATION
FOR
ALKALINE MANGANESE BATTERY
PREPARED BY:
APPROVED BY:
DATE:January 3, 2002
SPEC.NO.: REF----R44----0102
TECHNICAL SPECIFICATION
REF----R44----0102
1.Other name for the same type
L1325
4LR44
2.Chemical System
Alkaline Zinc—Manganese battery
(+) Zn|KOH|MnO2(-)
3.Nominal Voltage: 6.0V
4.Average Weight: 9.97g
5.Nominal Capacity: 145mAh
(continuous discharge at 20±2℃ under 0.22mA discharge current to 3.60V voltage)
6.Appearance:Metal Can
7.Electrical Characteristics:
7.1 Off—load Voltage:
New Battery≥6.05V
After 12 Months (Room Temp.)≥6.00V
7.2 Discharge Time(continuous discharge at 20±2℃ under 7.5KΩ discharge
load to 3.60V voltage)
New Battery≥190 hours
After 12 Months (Room Temp.)≥170 hours
7.3 Over—discharge Characteristic
Condition: 7.5KΩcontinuous discharge at 20±2℃&65±20%R.H.
Period: 48hours
Characteristic: No deformation is over 0.20mm of the nominal dimension,
and no visual electrolyte leakage
© DAILY POWER BATTERIES LTD.
Page 2 of 4
TECHNICAL SPECIFICATION
REF----R44----0102
8.Dimensions:
Nominal Dimension: ø13.00×25.20
(Unit: mm)
Range
A(ref.)
0.80
B
24.85±0.25
C
12.70±0.15
D(ref.)
0.20
D
B
A
Dimension
C
9. Typical Discharge Characteristics
(continuous discharge at 20±2℃ under 7.5KΩ discharge load to 3.60V voltage)
6. 40
6. 00
Voltage(V)
5. 60
5. 20
4. 80
4. 40
4. 00
3. 60
0
30
60
90
120
150
180
210
Discharge Time(hours)
© DAILY POWER BATTERIES LTD.
Page 3 of 4
TECHNICAL SPECIFICATION
REF----R44----0102
10. Mark:
The following message will be printed or stamped on the body of the
battery:
10.1 Designation: 4LR44、L1325 etc.
10.2 Manufacturer’s name:
10.3 Trademark: DPOWER.
10.4 Nominal Voltage: 6V.
10.5: Pole:
“+” and “-”.
10.6 Warning: May explode or leak if charged or disposed of in fire.
11. Caution for use :
11.1 There are risks of electrolyte leakage or causing damage to the device if
the battery is charged;
11.2 The battery shall be installed with “+”and “-” in correct position;
11.3 Short-circuiting and heating the battery、disposing of the can must not
be permitted.
—————END—————