Dixon DX60 Series Valve Manual
PDF
Dokument
Reklama
Reklama
Instruction & Operation Manual for DX60 Series Valve Read and understand this manual prior to installing, operating or servicing this equipment. 02/04/19 Table of Contents Safety ............................................................................................................................................................................3 Care of Stainless-Steel ...................................................................................................................................................... 5 Technical Specifications ..................................................................................................................................................... 6 Installation and Start-Up..................................................................................................................................................... 7 Unpacking .................................................................................................................................................................... 7 Tools Needed ............................................................................................................................................................... 7 Function Testing ......................................................................................................................................................................... 8 Orientation ................................................................................................................................................................... 8 Operation & Safety Labels ........................................................................................................................................... 9 Start-Up Cleaning ........................................................................................................................................................ 10 General Maintenance ......................................................................................................................................................... 11 Servicing Intervals ....................................................................................................................................................... 11 Lubrication ................................................................................................................................................................... 11 Inspection .................................................................................................................................................................... 12 Cleaning....................................................................................................................................................................... 12-13 Assembly and Disassembly ............................................................................................................................................... 13 Repair Kits .......................................................................................................................................................................... 22 Bill of Materials ................................................................................................................................................................... 23 Dimensions ........................................................................................................................................................................ 25 Model Numbers and Part Numbers.................................................................................................................................... 28 Troubleshooting ................................................................................................................................................................. 29 Certifications ...................................................................................................................................................................... 30 Warranty ............................................................................................................................................................................. 31 2 dixonvalve.com • 800.789.1718 DX60-Series | IOM Safety Information The following DANGER, WARNING and CAUTION signs are contained in this manual. To avoid serious injury and/or possible damage to equipment, pay attention to these messages. Hazards or unsafe practices could result in severe personal injury or death. DANGER is used in the most extreme cases. Hazards or unsafe practices which could result in minor or moderate injury. May also be used to alert against an unsafe operating or maintenance practice. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Safety logos, which appear throughout this manual, are used as a reminder that the user should carefully review for the appropriateness of the product for the media, application and environment in which it will be used. Use only replacement parts and devices recommended by the manufacturer to maintain the integrity of the equipment. Make sure the parts are properly matched to the series, model, serial number and revision level of the equipment. Safety labels are placed on equipment where appropriate. Do not remove any labeling from any piece of equipment. Replace any label that is missing. DO NOT modify any Dixon product. Non-factory modifications could create hazardous conditions and void all warranties. DO NOT attempt to use a Dixon product in any application that exceeds the product rating. General Guidelines • The owner must comply exclusively with these operating instructions and the authorized use of this piece of equipment. Should problems arise that cannot be solved using these operating instructions, please contact Dixon® – Sanitary Division. We will be happy to provide further assistance. • If any modification work is performed on the product by the owner themselves, Dixon ® shall no longer be considered the manufacturer of the device. In such cases, all components must be subjected to a new certification process for any applicable certifications that the equipment holds. Unless agreed to in writing by Dixon ®, liability, warranties and guarantees shall immediately be deemed null and void as soon as you: o Perform modifications/conversion work on the product. o Use the product for unauthorized purposes. o Remove or disable safety elements. o Process products whose material, form and size do not correspond exactly to the description provided. o Make alterations to the original state of the device. 3 • The operating instructions are regarded as part of the valve. • The operating and maintenance personnel must always be able to access the operating instructions. • The safety instructions provided in the operating instructions must be observed. • The operating instructions shall be valid for the entirety of the device's lifespan. • The operating instructions must be maintained and updated as necessary. • The operating instructions must be passed on to any subsequent owners or operators of the valve. dixonvalve.com • 800.789.1718 DX60-Series | IOM Safety Information Owner Must Ensure 4 • The valve is only used as authorized in this manual. • The valve is only used when it is in fault-free, fully functional condition, and that the safety equipment is regularly checked to ensure that it is fully functional. • The valve is only operated, maintained and repaired by personnel with the appropriate qualifications and authorization. • Checks are made before the valve is put into operation to ensure that only the authorized person is in the work area, and no one is in danger of being injured if the product is in operation. • The valve is checked for visual damage prior to commissioning to ensure that it is only operated when free of faults. • Any defects are reported immediately to the appropriate supervisor. • All safety and warning notices attached to the valve or near the valve are legible and none are removed. • The operating instructions are always kept close to the valve operation site, in a legible and complete state. • Personnel are regularly instructed on all occupational safety and environmental protection issues, and are familiar with and observe the operating instructions, especially the safety instructions contained herein. • Personnel are trained and supervised to ensure that they follow safety measures, including the obligatory use of personal protective equipment. • The valve is only connected to pipelines that are depressurized at the time of connection. • There is no tensile or compressive stress acting on the valve connections. • There is no residual risk at any point where high pressure could occur. High pressure can cause sudden failure in or damage to the lines and connections. • Warning notices in the documentation for supplier modules are observed and integrated into the risk assessments in the workplace. dixonvalve.com • 800.789.1718 DX60-Series | IOM Care of Stainless Steel The stainless-steel components in Dixon Sanitary equipment are machined, welded and assembled by skilled craftsmen using manufacturing methods that preserve the corrosion-resistant quality of the stainless-steel. Retention of corrosion-resistant qualities under processing conditions requires regular attention to the precautions listed below. 5 1. Regularly check all electrical devices connected to the equipment for stray currents caused by improper grounding, damaged insulation or other defects. Corrosion: Pitting often occurs when stray currents encounter moist stainless-steel. 2. Never leave rubber mats, fittings, wrenches, etc. in contact with stainless-steel. Corrosion: Pitting or galvanic action. Objects retard complete drying, preventing air from reforming the protective oxide film. Galvanic corrosion occurs when two dissimilar metals touch when wet. 3. Immediately rinse equipment after use with warm water until the rinse water is clear. Clean the equipment (manual or CIP) as soon as possible after rinsing. Corrosion: discoloration, deposits, pitting. Product deposits often cause pitting beneath the particles. 4. Use only recommended cleaning compounds. Purchase chemicals from reputable and responsible chemical manufacturers familiar with stainless-steel processing equipment they continuously check the effects of their products on stainless-steel. 5. Use cleaning chemicals exactly as specified by the manufacturer. Do not use excessive concentrations, temperatures or exposure times. Corrosion: Pitting, discoloration, stress cracks. Permanent damage often occurs from excessive chemical concentrations, temperatures or exposure times. 6. For manual cleaning, use only soft non-metallic brushes, sponges or pads. Brush with the grain on polished surfaces to avoid scratching the surface. Corrosion: Pitting, scratches. Metal brushes or sponges will scratch the surface and promote corrosion over a period of time. Metal particles allowed to remain on a stainless-steel surface will cause pitting. 7. Use chemical bactericides exactly as prescribed by the chemical manufacturer in concurrence with the local health authority. Use the lowest permissible concentration, temperature and exposure time possible. Flush immediately after bacterial treatment. In no case should the solution be in contact with stainless-steel for more than 20 minutes. Corrosion: Protective film destroyed. Chlorine and other halogen bactericides can destroy the protective film. A few degrees increase in temperature greatly increases chemical activity and accelerates corrosion. 8. Regularly inspect the joints in pipelines. Be sure all connections are tight fitting without binding. Corrosion: Crevice corrosion. Small crevices caused by improperly seated gaskets will promote crevice corrosion. Stainless-steel under stress will develop stress cracking, especially in the presence of bactericides containing chlorine. 9. Regularly inspect equipment for surface corrosion (i.e. pitting deposits, stress cracks, etc.). If deposit or color corrosion is detected, remove it immediately using mild scouring powder and detergents. Rinse thoroughly and allow to air dry. Review production and cleaning procedures to determine the cause. Note: If corrosion is not removed, the protective film cannot be restored, and corrosion will continue at an accelerated rate. dixonvalve.com • 800.789.1718 DX60-Series | IOM Technical Specifications Materials of Construction Technical Data • product contact components: 304 • non-product contact components: refer to BOM for individual component materials. Sealing Materials Technical Data • product contact components: 3A & FDA Grade FKM or Buna • non-product contact components: refer to BOM for individual component materials. Line Pressure Technical Data • max product line pressure: 75 PSI (5.17bar) Product Temperature Technical Data • max operating temperature: 212°F (100°C) For higher temperatures, consult factory. • minimum operating temperature: -20°F (-28.9°C) For lower temperatures, consult factory. • max ambient temperature: 140°F (60°C) Surface Finish Technical Data • product contact components: Ra ≤ 32 • optional finishes: upon request • non-product contact components: Ra ≤ 63 Connections • Flange with ANSI B16.5 Class 150# Flange Bolt Circle x Sanitary Male Threaded Bevel Seat Size • 3in Cleaning Method • CIP – models: sizes: DX60-Series. All Sizes. • COP – models: sizes: DX60-Series. All Sizes. Weight • Valve with standard plunger and valve cover: 27.0lbs • Valve with standard plunger and without valve cover: 24.6lbs • Valve with freeze rod plunger and valve cover: 28.0lbs • Valve with freeze rod plunger and without valve cover: 25.7lbs 6 dixonvalve.com • 800.789.1718 DX60-Series | IOM Installation & Start-Up The following should be performed upon receiving the valve and prior to installation and use of the valve. It is important that all the following processes and procedures are carefully followed and adhered to. Dixon ® is not responsible for any damage that occurs during the unpacking or installation process. Unpacking Carefully unpack the valve and inspect each part for any damage that may have occurred during shipment. The valve is shipped with a protective dust cover attached, so be sure to inspect the cover for any signs of damage as well as the valve itself. Report any damage to the carrier immediately. The valve is shipped with all necessary certificates and manuals. Please add this paperwork to the plant maintenance files for future use and reference. Additional information for the valve can be found at dixonvalve.com. The following items should be inspected for damage: Item # Description 1 Bevel Seat Nut 2 Bevel Seat Cap 3 Valve Housing 4 Valve Housing Cover Tools Needed The following tools will be required for any maintenance of the valve: • Item 1: Hammer • Item 2: 5/16” Allen Tool • Item 3: Punch • Item 4: 7/16” Box Wrench • Item 5: Jax PURgel KLEAR® • Item 6: O-Ring Pick • Item 7: Liquid Thread Locker (Not Shown) 2 3 4 5 1 6 7 dixonvalve.com • 800.789.1718 DX60-Series | IOM Installation & Start-Up Function Testing • Check visually to ensure that the equipment is not leaking. • Any defective seal that could have been damaged during disassembly or assembly must be replaced. • Check all equipment components for any signs of damage and replace damaged components. • Ensure that all bolts and clamps are securely tightened. • Ensure that any pneumatic hose connections are free of leaks if applicable. • Confirm all pipes and fittings connected to the equipment permitted for use are in the intended pressure range. • Check that the maximum pressure indicated on the equipment or in the specifications section of this manual has been complied with. Installation Orientation Equipment must be installed in the proper orientation to ensure proper functionality and cleanability. Please refer to the following diagrams below for proper installation. Figure 1 – Installation Orientation IMPORTANT: The valve must be installed with the outlet port facing downward if the valve is going to be cleaned-in-place (CIP’d). If the valve is installed with the outlet port in any other orientation other than what is depicted in Figure 1, the valve must be cleaned-outof-place (COP’d) in a COP tank. 8 dixonvalve.com • 800.789.1718 DX60-Series | IOM Operation & Safety Labels IMPORTANT: Each valve is supplied with operation instructions in the form of a 5in X 7in weatherproof sticker that must be installed on the back of the trailer so that the sticker can be clearly seen while operating the valve. This sticker is provided in both English & Spanish. Figure 2 shows an example of how the sticker should be placed on the trailer. Alternately, the sticker could be placed below or to the side of the valve, but it MUST be visible. Should the sticker degrade over time to the point that it is no longer readable, replace the sticker immediately. The sticker part number can be found in the BOM section of this manual. Figure 2 – Sticker Location Sticker Technical Specifications - Total Thickness - Adhesive Type - Min. Application Temperature - Service Temperature Range - Typical Service Life - Peel Adhesion (Stainless) 0.0073in ±10% Solvent Acrylic +45°F -40°F to +300°F 5 Years 4.2 lbs. Figure 3 – Sticker Example 9 dixonvalve.com • 800.789.1718 DX60-Series | IOM Cleaning IMPORTANT: Before operating the equipment during formal production, please follow the guidelines listed below to ensure that your equipment is clean and ready for service. • Ensure that the equipment is installed in a proper orientation to allow the equipment to be cleaned and drained properly. Reference the installation and startup section of the manual for orientation guidelines. • Flush the equipment with an appropriate cleaning agent to remove any residue that may be on the equipment from shipping. IMPORTANT: DO NOT use cleaning agents that will attack stainless-steel or the elastomers that were supplied with the valve. If you are unsure what elastomer is used in the valve, reference the part number key in this manual to make the determination. • Follow any MSDS instructions for proper use or handling of cleaning agents. • Flush the equipment sufficiently to remove any soiling from the product contact components. Depending on the process, there may be varying amounts of soiling. Cleaning times and cleaning agent concentrations will vary depending on the product being processed. It is the responsibility of the operator to determine and adjust these cleaning specifications as necessary. • The equipment should not be allowed to sit with product present in it for extended periods of time. Equipment should be cleaned immediately after processing is complete. 10 dixonvalve.com • 800.789.1718 DX60-Series | IOM General Maintenance To ensure proper operation of your Dixon® valve, proper maintenance must be performed at regular intervals. To prevent damage, check all fitting connections and screw connections for any loosening of the connections during equipment operation. Maintain adequate spare parts stock for all replacement components on the piece of equipment. Please refer to the repair kits section of the manual for complete component part numbers and kit part numbers. Servicing Intervals Recommended intervals for one shift operation would be 3 months. However, only the user/owner can determine the appropriate service intervals as the length between service intervals is dependent on the following parameters: • duration of use per day – number of cycles • type of product • product temperature • product viscosity • cleaning agent • type of cleaning (CIP/COP) Lubrication Please use the following chart below for proper grease type for varying component materials. DO NOT use mineral or animalproduct-based greases. Check all visible seals for any signs of damage and replace as necessary. For sliding surfaces, use Jax ® PurGel Klear food grade grease. If a different grease is used other than what is specified in this manual, there is risk of damaging the seals. Lubrication is only required when the equipment is being reassembled after servicing. 11 Seal Material Grease Type FKM JAX® PurGel Klear BUNA JAX® PurGel Klear PTFE Do Not Grease dixonvalve.com • 800.789.1718 DX60-Series | IOM General Maintenance Inspection Inspection of the components listed below should be done during regular servicing intervals. Before removing the valve from the trailer, please take care to do the following: • Clean the trailer completely to remove any product that may be harmful if contacting a person. • Drain the trailer completely that connects to the valve being serviced. • Make sure the valve is completely free of any product before removing from the trailer. • Once the valve has been removed from the trailer, cover the outlet of the trailer with a clean cotton rag to prevent any foreign material from entering the trailer. Components to be inspected (Refer to BOM Section of the manual): • Lip Seal (Item No. 6) • Plunger Seal (Item No. 8) • Bonnet Seal (Item No. 9) • Plunger (Item No. 4) • Bonnet (Item No. 3) • Valve Housing (Item No. 1) Any components that show signs of severe wear or damage should be replaced during the scheduled maintenance time for the equipment. Please refer to the assembly and disassembly section of this manual for proper instructions on removing and replacing any worn or damaged components. Replacement components and repair kits can be found in the BOM or repair kits section of this manual. Manual Cleaning (COP) 1. Refer to the disassembly section of the manual and follow instructions to remove all product contact components. 2. Inspect the product contact components of the equipment for any signs of possible damage. Replace components as necessary. (See the equipment BOM in this manual for replacement component part numbers.) 3. Clean all surfaces of the product contact components by manually brushing in a bath of cleaning solution (acid detergents or simple alkaline soda type detergents). 4. After cleaning, rinse all components thoroughly with water. 5. Refer to the assembly section of the manual and follow instructions to properly reassemble the equipment. Cleaning in Place (CIP) Note: Not all models or sizes may be certified for CIP. Please check the specifications section of the manual to determine what cleaning method is suitable. 1. Regularly flush the valve with a suitable medium to preserve seals and integrity of the product contact surfaces, such as when there is a product changeover or downtime. These intervals shall be determined by the end user. 2. Important: Only use cleaning agents which will not harm the seals and stainless-steel. 3. Follow any MSDS instructions for proper use or handling of cleaning agents. 4. The necessary cleaning times, temperatures and cleaning agents will depend on the degree of contamination and must be adapted accordingly. 5. Cleaning flow velocities of 5-6 ft/s should be maintained for proper cleaning of the equipment. 6. The valve plunger must be cycled between the “open” and “closed” positions during the CIP cleaning process to ensure that all product contact surfaces are properly exposed to the cleaning fluid. (See diagram) 12 dixonvalve.com • 800.789.1718 DX60-Series | IOM Push Close Pull Open Open Position Closed Position 7. After cleaning, rinse the equipment thoroughly with water. Assembly and Disassembly To ensure quality operation of your Dixon® equipment, the equipment must be disassembled and assembled properly to prevent equipment damage during operation. Please follow the instructions contained in this manual carefully and be sure to follow any safety warnings contained herein. If any questions should arise during the assembly or disassembly process that are not addressed in this manual, please feel free to contact Dixon® – Sanitary Division at 800.789.1718. Assembly 1. Grease the plunger seal O-Ring DX60-PS-V-30 with food grade grease install the plunger seal O-Ring onto the plunger DX60-PL-30 by pressing the O-Ring firmly into the O-Ring groove of the plunger. Press evenly around the diameter of the O-Ring to ensure that the ORing is sitting firmly in the groove. 13 dixonvalve.com • 800.789.1718 DX60-Series | IOM 2. Grease the bonnet seal O-Ring DX60-PS-V-30 and the lip seal DX60-LS-V-30 with food grade grease. Install the bonnet seal O-Ring on the bonnet by pressing the ORing firmly into the O-Ring groove of the bonnet being careful not to roll the O-Ring. 3. Grease the bonnet lip seal DX60-LS-V-30 liberally with food grade grease. Install the lip seal into the gland in the bonnet and press firmly into place. Pinching the lip seal will help to fit the seal into the gland groove. Ensure the seal is sitting securely in the bonnet and that there are no gaps between the lip seal and the bonnet face. Bonnet Cross Section There should be no large gaps between the stainless & the rubber. 14 dixonvalve.com • 800.789.1718 DX60-Series | IOM Assembly 4. Insert the plunger DX60-PL-30 carefully through the lip seal and bonnet. Check the lip seal to ensure that it was not damaged in any way. 5. Install stem bushing DX60-SB-30 onto the plunger stem and slide bushing down until it contacts the bonnet securely. 15 dixonvalve.com • 800.789.1718 DX60-Series | IOM Assembly 6. Install bonnet hub flange DX60-BF-30 by sliding it onto the plunger stem and pressing down until it contacts the bonnet. Align the clearance holes in the bonnet hub flange with the threaded holes in the bonnet. Insert the bonnet hub flange bolts DX60-BFHB-30 through the clearance holes and tighten the bolts to 75in-lb. Note: apply thread locker to the bolts. 7. Install the handle DX60-HA-30 onto the plunger stem being sure to line up the machined flat on the handle with the machined flat on the plunger stem. See diagram below. Apply thread locker to the plunger handle bolt DX60-HAB-30 & tighten using a 5/16” Allen. 16 dixonvalve.com • 800.789.1718 DX60-Series | IOM Assembly 8. Insert the plunger/bonnet/handle assembly into the valve housing making sure to align the bonnet locating pin with the notch in the valve housing. Install the body clamp DX60-CLMP-30 and tighten the wing nut securely. Disassembly 1. Remove plunger handle bolt DX60-HAB-30 using a 5/16” Allen tool and then remove handle DX60-HA-30. 17 dixonvalve.com • 800.789.1718 DX60-Series | IOM 2. Remove body clamp DX60-CLMP-30 by loosening the wing nut with your hand. Remove the plunger & bonnet assembly from the valve body DX60-BDY-30. 3. Remove the plunger DX60-PL-30 from the valve bonnet DX60-BON-30 and inspect for any signs of damage. Replace any components as necessary 18 dixonvalve.com • 800.789.1718 DX60-Series | IOM 4. Remove the bonnet flange bolts DX60-BFHB-30 from the bonnet hub flange DX60-BF-30 using a 7/16” box wrench. Remove the bonnet hub flange from the bonnet DX60-BON-30. 5. Remove the stem bushing DX60-SB-30 from the bonnet hub flange DX60-BF-30. 19 dixonvalve.com • 800.789.1718 DX60-Series | IOM 5a. Using a punch tool and hammer, knock out the handle pins G100HRP from the bonnet hub flange. Note: Handle cam arms G100HR only require disassembly if arms are damaged or worn and require replacement. 5b. Remove handle pins G100HRP and handle cam arms G100HR from bonnet hub flange DX60-BF-30. 20 dixonvalve.com • 800.789.1718 DX60-Series | IOM Disassembly 6. Remove the plunger seal O-Ring DX60-PS-V-30 from the plunger DX60-PL-30 using an O-Ring pick tool. You may need to pierce the O-Ring through to remove. 7. Remove bonnet seal O-Ring DX60-BS-V-30 and the lip seal DX60-LS-V-30 from the bonnet DX60-BON-30 using and O-Ring pick tool. You will need to pierce the lip seal to remove. 21 dixonvalve.com • 800.789.1718 DX60-Series | IOM Repair Kits To ensure proper operation of your Dixon® valve, proper maintenance must be performed at regular intervals. To prevent damage and improper operation, use only genuine replacement parts and kits offered by Dixon ® to maintain the integrity of the valve. Make sure the parts are properly matched to the series, model, serial number and revision level of the equipment. Please see the list of kits below offered for this piece of equipment: 9 6 8 22 Valve Size Lip Seal Material (Item 6) Plunger Seal Material (Item 8) Bonnet Seal Material (Item 9) Kit Part Number Kit Includes 3" — FKM FKM DX60-30-SK1-V Items 8, 9 3" FKM FKM FKM DX60-30-SK2-V Items 6, 8, 9 3" — Buna Buna DX60-30-SK1-B Items 8, 9 3" Buna Buna Buna DX60-30-SK2-B Items 6, 8, 9 dixonvalve.com • 800.789.1718 DX60-Series | IOM Bill of Materials Part Type Part Number Item No. Material Body Housing DX60-BDY-30 1* 304 DX60 Body [3in Valve] 1 Bonnet Hub Flange DX60-BF-30 2 304 DX60 Bonnet Hub Flange [3in Valve] 1 Bonnet DX60-BON-30 3* 304 DX60 Bonnet [3in Valve] 1 Plunger DX60-PL-30 4a* 304 DX60 Plunger [3in Valve] 1 Plunger - Freeze Rod (Optional) DX60-PL-30-R 4b 304 DX60 Plunger With Freeze Rod [3in Valve} 1 Stem Bushing DX60-SB-30 5 PTFE DX60 Stem Bushing [3in Valve] 1 23 Description Qty Lip Seal DX60-LS-V-30 6* FKM DX60 FKM Lip Seal [3in Valve] 1 Body Clamp DX60-CLMP-30 7 304 DX60 Body Clamp [3in Valve] 1 Plunger Seal DX60-PS-V-30 8* FKM DX60 FKM Plunger Seal [3in Valve] 1 Bonnet Seal DX60-BS-V-30 9* FKM DX60 FKM Bonnet Seal [3in Valve] 1 Plunger Handle DX60-HA-30 10 304 DX60 Plunger Handle [3in Valve] 1 Handle Cam Arm G100HR 11 304 Handle Cam Arm 2 Pin G100P 12 304 Handle Pin 2 Bevel Seat Cap DX60-16A-G30 13* 304 DX60 Bevel Seat Cap [3in Valve] 1 Bevel Seat Nut 13H-G300 14 304 3in Bevel Seat Nut 1 Bonnet Locating Pin DX60-BLP-30 15 ABS DX60 Bonnet Locating Pin [3in Valve] 1 Bonnet Marker - Red DX60-BMR 16 Nylon DX60 Red Bonnet Marker 1 Bonnet Marker - Green DX60-BMG 17 Nylon DX60 Green Bonnet Marker 1 Bonnet Flange Bolt DX60-BFHB-30 18 18-8 DX60 Bonnet Flange Bolt [3in Valve] 2 Plunger Handle Bolt DX60-HAB-30 19 304 DX60 Plunger Handle Bolt 1 Valve Housing Cover DX60-DC-30-AL 20** AL DX60 Valve Housing Cover [3in Valve] 1 dixonvalve.com • 800.789.1718 DX60-Series | IOM Dust Cover Eye Bolt DX60-DCEB-30 20a 304 DX60 Dust Cover Eye Bolt 1 Dust Cover Nut Washer DX60-DCNW-30 20b 18-8 DX60 Dust Cover Nut Washer 1 Dust Cover Nut Washer DX60-DCN-30 20c AL DX60 Dust Cover Nut 1 Dust Cover Lanyard DX60-DCL-30 20d 304 DX60 Dust Cover Lanyard 1 Body Clamp Wing Nut DX60-13DWN 21 304 DX60 Body Clamp Wing Nut 1 * Optionally Available Materials (See Table Below For Component Part Numbers) Part Type Part Number Item No. Material Body Housing DX60-BDY-30R 1 316L DX60 Body [3in Valve], 316L 1 Bonnet DX60-BON-30R 3 316L DX60 Bonnet [3in Valve], 316L 1 Plunger DX60-PL-30R 4a 316L DX60 Plunger [3in Valve], 316L 1 Bevel Seat Cap DX60-16A-G30R 13 316L DX60 Bevel Seat Cap [3in Valve], 316L 1 Lip Seal DX60-LS-B-30 6 Buna DX60 Buna Lip Seal [3in Valve] 1 Plunger Seal DX60-PS-B-30 8 Buna DX60 Buna Plunger Seal [3in Valve] 1 Bonnet Seal DX60-BS-B-30 9 Buna DX60 Buna Bonnet Seal [3in Valve] 1 Description Qty ** When ordering the cover as a repair part, order using part number DX60-DC-30-ALRK 24 dixonvalve.com • 800.789.1718 DX60-Series | IOM Dimensions DX60 With Standard Plunger – Cover Removed 25 Valve Size A B C D E F 3in 2.87in 3.22in 9.10in 3.29in 9.23in 3in Male Threaded Bevel dixonvalve.com • 800.789.1718 DX60-Series | IOM Dimensions cont. DX60 With Freeze Rod Plunger – Cover Removed Valve Size Plunger Closed Position Plunger Open Position 3in 8.00in 4.44in Note: All other dimensions of DX60 valve with optional freeze rod plunger are the same as the valve with standard plunger. Refer to the drawing on the previous page for additional dimensions. 26 dixonvalve.com • 800.789.1718 DX60-Series | IOM Dimensions cont. Valve Size A (4X) øB 3in 0.69in 6.00in DX60 Valve – Flange Bolt Circle Valve Size C D E 3in 10.98in 9.66in 9.57in DX60 Valve – Cover Installed 27 dixonvalve.com • 800.789.1718 DX60-Series | IOM Part Number Key To ensure proper specification of your Dixon ® DX60-Series valve, below is the complete valve part number key to configure the valve with the options that meet your specific requirements. To determine what seal material or valve component material your current valve is constructed of, refer to the complete part number that is laser marked on the flange of the valve. If you require an option that is not listed in this key, please feel free to contact Dixon® – Sanitary Division at 800.789.1718. DX60 Valve Size — 3.0in Valve Body Style — L (2-port Shut-Off) Surface Finish — 32 Ra (ID Mech. Polish) Connections — Flange x Male Threaded Bevel Stainless Steel Wetted Parts 1 Code Code FKM V — Buna (Optional) B Code — Aluminum 1 — No Cover 2 28 1 Code — Plunger With Freeze Rod V A R None G Code G — 1 Options 10 316L (Optional) — A Valve Cover Code 304 Options 10 Seal Material 30 — Valve Cover 30 Material Code — Seal Material Valve Body Valve Series Dixon DX60-Series Part Number Key Code Blank R dixonvalve.com • 800.789.1718 DX60-Series | IOM Troubleshooting Problem Possible Cause Plunger seal, bonnet seal, or lip seal damaged. Valve is leaking Body clamp is not tightened properly. Handle cam arms are not engaged. Suggested Action Check seals for any type of damage and replace as necessary. Tighten wing nut on body clamp. Push cam arms in tightly so they are completely secure. Plunger seal may be frozen to the valve housing. Rotate handle to break free. Valve was not cleaned after running a sticky or tacking product. Clean valve according to the cleaning instructions found in this manual. Check plunger lock arm or bonnet damaged. Check plunger lock arm & bonnet for any signs of damage. Repair as necessary. Accumulated product on the plunger or bonnet from not cleaning properly. Clean valve according to the cleaning instructions found in this manual. Damaged dust cover. Inspect cover for any signs of warping or damage around the diameter. Replace as necessary. Valve won't open Valve will not lock open Dust cover will not go on Significant damage to the valve housing flange. Worn PTFE stem bushing. Plunger alignment loose 29 Bonnet flange bolts are loose. Inspect valve housing flange for any signs of damage around where the cover meets the flange. Repair as necessary. Inspect bushing for signs of wear and replace as necessary. Tighten bolts properly per the assembly instructions given in this manual. dixonvalve.com • 800.789.1718 DX60-Series | IOM Certificates 30 dixonvalve.com • 800.789.1718 DX60-Series | IOM Limited Warranty DIXON VALVE AND COUPLING COMPANY (herein called "Dixon") warrants the products described herein and manufactured by Dixon to be free from defects in material and workmanship for a period of one (1) year from date of shipment by Dixon under normal use and service. Its sole obligation under this warranty being limited to repairing or replacing, as hereinafter provided, at its option any product found to Dixon's satisfaction to be defective upon examination by it, provided that such product shall be returned for inspection to Dixon's factory within three (3) months after discovery of the defect. The repair or replacement of defective products will be made without charge for parts or labor. This warranty shall not apply to: (a) parts or products not manufactured by Dixon, the warranty of such items being limited to the actual warranty extended to Dixon by its supplier; (b) any product that has been subject to abuse, negligence, accident, or misapplication; (c) any product altered or repaired by others than Dixon; and (d) to normal maintenance services and the replacement of service items (such as washers, gaskets and lubricants) made in connection with such services. To the extent permitted by law, this limited warranty shall extend only to the buyer and any other person reasonably expected to use or consume the goods who is injured in person by any breach of the warranty. No action may be brought against Dixon for an alleged breach of warranty unless such action is instituted within one (1) year from the date the cause of action accrues. This limited warranty shall be construed and enforced to the fullest extent allowable by applicable law. Other than the obligation of Dixon set forth herein, Dixon disclaims all warranties, express or implied, including but not limited to any implied warranties of merchantability or fitness for a particular purpose, and any other obligation or liability. The foregoing constitutes Dixon's sole obligation with respect to damages, whether direct, incidental or consequential, resulting from the use or performance of the product. Some products and sizes may be discontinued when stock is depleted or may require a minimum quantity for ordering. 31 dixonvalve.com • 800.789.1718 DX60-Series | IOM ">
/
Preuzimanje
Samo prijateljski podsetnik. Dokument možete pogledati ovde. Ali što je najvažnije, naš AI ga je već pročitao. Može da objasni složene stvari jednostavnim rečima, odgovori na vaša pitanja na bilo kom jeziku i pomogne vam da brzo navigirate čak i najdužim ili najkomplikovanijim dokumentima.
Reklama