Samsung AR18TQHQCWK/MG User manual
Below you will find brief information for AR12TQHQCWK, AR18TQHQCWK, AR24TQHQCWK, AR30TQHQCWK, AR12TRHQGWK, AR18TRHQHWK, AR24TRHQGWK, AR30TRHQGWK. These Samsung air conditioners offer features like auto-restart after power loss, anti-mildew function, and optional wireless control. They are designed for efficient cooling and heating with sleep operation to optimize energy use. The manual also provides safety precautions and troubleshooting tips.
Advertisement
Advertisement
Air conditioner
User manual / Installation manual / Remote manual
AR**T*HQ*WK*MG
• Thank you for purchasing this samsung air conditioner.
• Before operating this unit, please read this user manual carefully and retain it for future reference.
1
Table of Contents
Safety Precautions ....................................................................................
03
Owner’s Manual
Unit Specifications and Features
............................................................
07
1. Technical Specifications ………………………………………………………………………………………07
2. Indoor unit display ……………………………………………………………………………………………15
3. Operating temperature ………………………………………………………………………………………16
4. Other features …………………………………………………………………………………………………17
5. Setting angle of airflow ………………………………………………………………………………………18
6. Manual operation (without Remote) …………………………………………………………………………18
Care and Maintenance ..............................................................................
19
Troubleshooting ........................................................................................
21
Installation Manual
Accessories .................................................................................................
24
Packing and Unpacking ...............................................................................
Installation Summary - Indoor Unit ...............................................................
25
26
Unit Parts .........................................................................................27
Indoor Unit Installation ....................................................................28
1. Select installation location ……………………………………………………………………………………28
2. Attach mounting plate to wall ………………………………………………………………………………28
3. Drill wall hole for connective piping …………………………………………………………………………29
4. Prepare refrigerant piping ……………………………………………………………………………………30
5. Connect drain hose …………………………………………………………………………………………30
6. Connect signal cable …………………………………………………………………………………………31
7. Wrap pipes and cables ………………………………………………………………………………………32
8. Mount indoor unit ……………………………………………………………………………………………33
Outdoor Unit Installation ..........................................................................
34
1. Select installation location ……………………………………………………………………………………34
2. Install drain joint ………………………………………………………………………………………………35
3. Anchor outdoor unit …………………………………………………………………………………………35
4. Connect signal and power cables …………………………………………………………………………37
Refrigerant Piping Connection ................................................................
38
A. Note on Pipe Length …………………………………………………………………………………………38
B. Connection Instructions – Refrigerant Piping ……………………………………………………………38
1. Cut pipe ……………………………………………………………………………………………………38
2. Remove burrs ……………………………………………………………………………………………39
3. Flare pipe ends ……………………………………………………………………………………………39
4. Connect pipes ……………………………………………………………………………………………39
Air Evacuation ...........................................................................................
41
1. Evacuation Instructions ………………………………………………………………………………………41
2. Note on Adding Refrigerant …………………………………………………………………………………42
Electrical and Gas Leak Checks ..............................................................
43
Test Run .....................................................................................................
44
Inpedance Information ................................................................ 45
Please check the applicable models, technical data, F-GAS (if any) and manufacturer information from the “Owner’s Manual - Product Fiche “ in the packaging of the outdoor unit. (European Union products only)
2
Owner’s Manual &
Installation Manual
Safety Precautions
Read Safety Precautions Before Operation and Installation
Incorrect installation due to ignoring instructions can cause serious damage or injury.
The seriousness of potential damage or injuries is classified as either a WARNING or
CAUTION .
WARNING
This symbol indicates the possibility of personnel injury or loss of life.
CAUTION
This symbol indicates the possibility of property damage or serious consequences.
WARNING
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision (EN Standard requirements).
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance (IEC Standard requirements).
WARNINGS FOR PRODUCT USE
● If an abnormal situation arises (like a burning smell), immediately turn off the unit and disconnect the power. Call your dealer for instructions to avoid electric shock, fire or injury.
● Do not insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating at high speeds.
● Do not use flammable sprays such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.
● Do not operate the air conditioner in places near or around combustible gases. Emitted gas may collect around the unit and cause explosion.
● Do not operate your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
● Do not expose your body directly to cool air for a prolonged period of time.
● Do not allow children to play with the air conditioner. Children must be supervised around the unit at all times.
● If the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.
● In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed air-conditioning units is highly recommended.
3
Owner’s Manual &
Installation Manual
CLEANING AND MAINTENANCE WARNINGS
● Turn off the device and disconnect the power before cleaning. Failure to do so can cause electrical shock.
● Do not clean the air conditioner with excessive amounts of water.
● Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents can cause fire or deformation.
CAUTION
● Turn off the air conditioner and disconnect the power if you are not going to use it for a long time.
● Turn off and unplug the unit during storms.
● Make sure that water condensation can drain unhindered from the unit.
● Do not operate the air conditioner with wet hands. This may cause electric shock.
● Do not use device for any other purpose than its intended use.
● Do not climb onto or place objects on top of the outdoor unit.
● Do not allow the air conditioner to operate for long periods of time with doors or windows open, or if the humidity is very high.
ELECTRICAL WARNINGS
● Only use the specified power cord. If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
● Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty plugs can cause fire or electric shock.
● Do not pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling directly on the cord can damage it, which can lead to fire or electric shock.
● Do not modify the length of the power supply cord or use an extension cord to power the unit.
● Do not share the electrical outlet with other appliances. Improper or insufficient power supply can cause fire or electrical shock.
● The product must be properly grounded at the time of installation, or electrical shock may occur.
● For all electrical work, follow all local and national wiring standards, regulations, and the Installation
Manual. Connect cables tightly, and clamp them securely to prevent external forces from damaging the terminal. Improper electrical connections can overheat and cause fire, and may also cause shock. All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units.
● All wiring must be properly arranged to ensure that the control board cover can close properly. If the control board cover is not closed properly, it can lead to corrosion and cause the connection points on the terminal to heat up, catch fire, or cause electrical shock.
● If connecting power to fixed wiring, an all-pole disconnection device which has at least 3mm clearances in all poles, and have a leakage current that may exceed 10mA, the residual current device (RCD) having a rated residual operating current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner’s circuit board (PCB) is designed with a fuse to provide overcurrent protection.
The specifications of the fuse are printed on the circuit board, such as:
Indoor unit: T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, etc.
Outdoor unit: T20A/250VAC (<=18000Btu/h units), T30A/250VAC (>18000Btu/h units)
4
Owner’s Manual &
Installation Manual
WARNINGS FOR PRODUCT INSTALLATION
1. Installation must be performed by an authorized dealer or specialist. Defective installation can cause water leakage, electrical shock, or fire.
2. Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
(In North America,installation must be performed in accordance with the requirement of NEC and
CEC by authorized personnel only.)
3. Contact an authorized service technician for repair or maintenance of this unit. This appliance shall be installed in accordance with national wiring regulations.
4. Only use the included accessories, parts, and specified parts for installation. Using non-standard parts can cause water leakage, electrical shock, fire, and can cause the unit to fail.
5. Install the unit in a firm location that can support the unit’s weight. If the chosen location cannot support the unit’s weight, or the installation is not done properly, the unit may drop and cause serious injury and damage.
6. Install drainage piping according to the instructions in this manual. Improper drainage may cause water damage to your home and property.
7. For units that have an auxiliary electric heater, do not install the unit within 1 meter (3 feet) of any combustible materials.
8. Do not install the unit in a location that may be exposed to combustible gas leaks. If combustible gas accumulates around the unit, it may cause fire.
9. Do not turn on the power until all work has been completed.
10. When moving or relocating the air conditioner, consult experienced service technicians for disconnection and reinstallation of the unit.
11. How to install the appliance to its support, please read the information for details in “indoor unit installation” and “outdoor unit installation” sections .
5
Owner’s Manual &
Installation Manual
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal.
Correct disposal of batteries in this product
This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66.
6
Owner’s Manual &
Installation Manual
Unit Specifications and Features
Technical Specifications
Outdoor
Power supply
Cooling(T1)
Capacity
Input
Rated current
EER
EER Grade
Capacity
Cooling(T3) Input
Rated current
EER
Capacity
Heating
Input
Rated current
COP
Max. input consumption
Max. current
Starting current
Indoor air flow (Turbo/Hi/Mi/Lo)
Indoor noise level (Hi/Lo)
Indoor unit
Outdoor unit
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Refrigerant type
Design pressure
Refrigerant piping
Connection wiring
Plug type
Thermostat type
Operation temperature
Liquid side/ Gas side
Max. refrigerant pipe length
Max. difference in level
Room temperature
Indoor(cooling/ heating)
Outdoor(cooling/heating)
Country of origin
V-Hz-Ph
Btu/h kW
W
A
(Btu/h)/W
Btu/h kW
W
A
(Btu/h)/W
W
W
A
W/W
W
A
A m3/h dB(A) mm mm
Kg mm mm
Kg kg
MPa mm(inch) m m
°C
°C
°C
AR12TQHQCWK
230V,1Ph,60Hz
11800
3.45
952
4.3
12.40
D
10200
2.97
1172
5.1
8.70
3300
943
4.1
3.50
1490
7.6
27
750/710/628/506
44/34
965x215x319
1045x305x410
11.5/14.8
770x300x555
900x348x625
33.9/36.6
R410A/1.1
4.8/1.5
Φ6.35(1/4in)/Φ12.7(1/2in)
20
8
3x1.5(Optional)+2x0.75
1.5x3/no-plug
Remote Control
17-30
17-32/0-30
18-52/-7-24
CHINA
7
Outdoor
Power supply
Cooling(T1)
Capacity
Input
Rated current
EER
EER Grade
Capacity
Cooling(T3) Input
Rated current
EER
Capacity
Heating
Input
Rated current
COP
Max. input consumption
Max. current
Starting current
Indoor air flow (Turbo/Hi/Mi/Lo)
Indoor noise level (Hi/Lo)
Indoor unit
Outdoor unit
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Refrigerant type
Design pressure
Refrigerant piping
Connection wiring
Plug type
Thermostat type
Operation temperature
Liquid side/ Gas side
Max. refrigerant pipe length
Max. difference in level
Room temperature
Indoor(cooling/ heating)
Outdoor(cooling/heating)
Country of origin
Owner’s Manual &
Installation Manual
V-Hz-Ph
Btu/h kW
W
A
(Btu/h)/W
Btu/h kW
W
A
(Btu/h)/W
W
W
A
W/W
W
A
A m3/h dB(A) mm mm
°C
°C
°C
AR18TQHQCWK
230V,1Ph,60Hz
18000
5.28
1452
6.5
12.40
D
15900
4.65
1797
7.8
8.85
5100
1645
7.2
3.10
2120
10.7
34
1184/1089/1006
51/47
1080x226x335
1155x415x320
Kg mm mm
Kg
15.1/18.8
890x342x673
995x435x750
49.2/52.5
kg
MPa mm(inch) 6.35mm(1/4in)/15.9mm(5/8in) m m
R410A/1.96
4.8/1.5
25
10
1.5x3/0.75x2
2.5x3/no-plug
(Remote Control)
17-30
17-32/0-30
18-52/-7-24
CHINA
8
Owner’s Manual &
Installation Manual
Outdoor
Power supply
Cooling(T1)
Capacity
Input
Rated current
EER
EER Grade
Capacity
Cooling(T3) Input
Rated current
EER
Capacity
Heating
Input
Rated current
COP
Max. input consumption
Max. current
Starting current
Indoor air flow (Turbo/Hi/Mi/Lo)
Indoor noise level (Hi/Lo)
Indoor unit
Outdoor unit
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Refrigerant type
Design pressure
Refrigerant piping
Connection wiring
Plug type
Thermostat type
Operation temperature
Liquid side/ Gas side
Max. refrigerant pipe length
Max. difference in level
Room temperature
Indoor(cooling/ heating)
Outdoor(cooling/heating)
Country of origin
V-Hz-Ph
Btu/h kW
W
A
(Btu/h)/W
Btu/h kW
W
A
(Btu/h)/W
W
W
A
W/W
W
A
A m3/h dB(A) mm mm
°C
°C
°C
AR24TQHQCWK
230V,1Ph,60Hz
22000
6.42
1781
7.9
12.35
D
18400
5.40
2114
9.4
8.70
6450
1792
8.0
3.60
2500
12.6
50
1200/1100/1010
52/48
1080x226x335
1155x415x320
Kg mm mm
Kg
13.9/17.6
946x410x810
1090x500x885
62.5/67.3
kg
MPa mm(inch) 9.52mm(3/8in)/15.9mm(5/8in) m m
R410A/2.22
///
25
10
2.5x3/0.75x3
2.5x3/no-plug
(Remote Control)
17-30
17-32/0-30
18-54/-7-24
CHINA
9
Outdoor
Power supply
Cooling(T1)
Capacity
Input
Rated current
EER
EER Grade
Capacity
Cooling(T3) Input
Rated current
EER
Capacity
Heating
Input
Rated current
COP
Max. input consumption
Max. current
Starting current
Indoor air flow (Turbo/Hi/Mi/Lo)
Indoor noise level (Hi/Lo)
Indoor unit
Outdoor unit
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Refrigerant type
Design pressure
Refrigerant piping
Connection wiring
Plug type
Thermostat type
Operation temperature
Liquid side/ Gas side
Max. refrigerant pipe length
Max. difference in level
Room temperature
Indoor(cooling/ heating)
Outdoor(cooling/heating)
Country of origin
Owner’s Manual &
Installation Manual
V-Hz-Ph
Btu/h kW
W
A
(Btu/h)/W
Btu/h kW
W
A
(Btu/h)/W
W
W
A
W/W
W
A
A m3/h dB(A) mm mm
°C
°C
°C
AR30TQHQCWK
230V,1Ph,60Hz
27000
7.90
2180
9.7
12.40
D
23800
6.96
2645
11.7
9.00
7750
2095
9.3
3.70
3500
18
60
1343/1237/1103
55/48
1259x282x362
1340x450x385
Kg mm mm
Kg
20.3/26.1
946x410x810
1090x500x885
66.9/71.8
kg
MPa mm(inch) 9.52mm(3/8in)/19mm(3/4in) m m
R410A/2.6
4.8/1.5
25
10
2.5x3/0.75x3
2.5x3/no-plug
(Remote Control)
17-30
17-32/0-30
18-52/-7-24
CHINA
10
Owner’s Manual &
Installation Manual
Outdoor
Power supply
Cooling(T1)
Capacity
Input
Rated current
EER
EER Grade
Capacity
Cooling(T3) Input
Rated current
EER
Capacity
Heating
Input
Rated current
COP
Max. input consumption
Max. current
Starting current
Indoor air flow (Turbo/Hi/Mi/Lo)
Indoor noise level (Hi/Lo)
Indoor unit
Outdoor unit
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Refrigerant type
Design pressure
Refrigerant piping
Connection wiring
Plug type
Thermostat type
Operation temperature
Liquid side/ Gas side
Max. refrigerant pipe length
Max. difference in level
Room temperature
Indoor(cooling/ heating)
Outdoor(cooling/heating)
Country of origin
V-Hz-Ph
Btu/h kW
W
A
(Btu/h)/W
Btu/h kW
W
A
(Btu/h)/W
W
W
A
W/W
W
A
A m3/h dB(A) mm mm
Kg mm mm
Kg kg
MPa mm(inch) m m
°C
°C
°C
AR12TRHQGWK
230V,1Ph,60Hz
12000
3.51
1000
4.5
12.00
D
10400
3.03
1195
5.3
8.70
/
/
/
/
1490
7.6
27
750/690/610/490
43/34
965x215x319
1045x305x405
11.5/15
770x300x555
900x345x585
30.1/33
R410A/0.85
4.8/1.5
Φ6.35/Φ12.7(1/4"/1/2")
20
8
3x1.5(Optional)
3x1.5/(no-plug)
Remote Control
17-30
17-32/----
18-52/----
CHINA
11
Outdoor
Power supply
Cooling(T1)
Capacity
Input
Rated current
EER
EER Grade
Capacity
Cooling(T3) Input
Rated current
EER
Capacity
Heating
Input
Rated current
COP
Max. input consumption
Max. current
Starting current
Indoor air flow (Turbo/Hi/Mi/Lo)
Indoor noise level (Hi/Lo)
Indoor unit
Outdoor unit
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Refrigerant type
Design pressure
Refrigerant piping
Connection wiring
Plug type
Thermostat type
Operation temperature
Liquid side/ Gas side
Max. refrigerant pipe length
Max. difference in level
Room temperature
Indoor(cooling/ heating)
Outdoor(cooling/heating)
Country of origin
V-Hz-Ph
Btu/h kW
W
A
(Btu/h)/W
Btu/h kW
W
A
(Btu/h)/W
W
W
A
W/W
W
A
A m3/h dB(A) mm mm
Kg mm mm
Kg kg
MPa mm(inch) m m
°C
°C
°C
Owner’s Manual &
Installation Manual
AR18TRHQHWK
230V,1Ph,60Hz
18000
5.28
1500
6.5
12.00
D
15200
4.44
1790
7.8
8.50
/
/
/
/
2120
10.7
34
1210/1160/960/880
50/43
1080x226x335
1155x415x315
14.9/18.7
845x363x702
965x395x765
47.1/51
R410A/1.3
4.8/1.5
Φ6.35/Φ15.9(1/4"/5/8")
25
10
3x2.5(Optional)
3x2.5/(no-plug)
Remote Control
17-30
17-32/----
18-52/----
CHINA
12
Owner’s Manual &
Installation Manual
Outdoor
Power supply
Cooling(T1)
Capacity
Input
Rated current
EER
EER Grade
Capacity
Cooling(T3) Input
Rated current
EER
Capacity
Heating
Input
Rated current
COP
Max. input consumption
Max. current
Starting current
Indoor air flow (Turbo/Hi/Mi/Lo)
Indoor noise level (Hi/Lo)
Indoor unit
Outdoor unit
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Refrigerant type
Design pressure
Refrigerant piping
Connection wiring
Plug type
Thermostat type
Operation temperature
Liquid side/ Gas side
Max. refrigerant pipe length
Max. difference in level
Room temperature
Indoor(cooling/ heating)
Outdoor(cooling/heating)
Country of origin
V-Hz-Ph
Btu/h kW
W
A
(Btu/h)/W
Btu/h kW
W
A
(Btu/h)/W
W
W
A
W/W
W
A
A m3/h dB(A) mm mm
°C
°C
°C
AR24TRHQGWK
230V,1Ph,60Hz
21400
6.27
1754
7.8
12.20
D
17800
5.19
2094
9.3
8.50
/
/
/
/
2580
13.2
50
1200/1100/1010
50/45
1080x226x335
1155x415x320
Kg mm mm
Kg
14.1/17.8
946x410x810
1090x500x885
60.9/65.5
kg
MPa mm(inch) 9.52mm(3/8in)/15.9mm(5/8in) m m
R410A/2.2
4.8/1.5
25
10
2.5x4//
2.5x3/no-plug
(Remote Control)
17-30
17-32//
18-52//
CHINA
13
Outdoor
Power supply
Cooling(T1)
Capacity
Input
Rated current
EER
EER Grade
Capacity
Cooling(T3) Input
Rated current
EER
Capacity
Heating
Input
Rated current
COP
Max. input consumption
Max. current
Starting current
Indoor air flow (Turbo/Hi/Mi/Lo)
Indoor noise level (Hi/Lo)
Indoor unit
Outdoor unit
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Dimension(W*D*H)
Packing (W*D*H)
Net/Gross weight
Refrigerant type
Design pressure
Refrigerant piping
Connection wiring
Plug type
Thermostat type
Operation temperature
Liquid side/ Gas side
Max. refrigerant pipe length
Max. difference in level
Room temperature
Indoor(cooling/ heating)
Outdoor(cooling/heating)
Country of origin
V-Hz-Ph
Btu/h kW
W
A
(Btu/h)/W
Btu/h kW
W
A
(Btu/h)/W
W
W
A
W/W
W
A
A m3/h dB(A) mm mm
Kg mm mm
Kg kg
MPa mm(inch) m m
°C
°C
°C
GCC MODEL
AR12TQHQCWK
AR18TQHQCWK
AR24TQHQCWK
AR30TQHQCWK
AR12TRHQGWK
AR18TRHQHWK
AR24TRHQGWK
AR30TRHQGWK
Owner’s Manual &
Installation Manual
AR30TRHQGWK
230V,1Ph,60Hz
27200
7.95
2230
9.7
12.20
D
22600
6.63
2613
11.5
8.65
/
/
/
/
3320
17.1
60
1480/1400/1230/1000
53/43
1259x282x362
1340x450x380
22.8./28.5
946x410x810
1090x500x875
64.9/69.4
R410A/2.55
4.8/1.5
Φ9.52/Φ19(3/8"/3/4")
25
10
4x2.5(Optional)
3x2.5/(no-plug)
Remote Control
17-30
17-32/----
18-52/----
CHINA
14
Owner’s Manual &
Installation Manual
Indoor unit display
NOTE: Different models have different front panel and display window. Not all the indicators describing below are available for the air conditioner you purchased. Please check the indoor display window of the unit you purchased.
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail.
Front Panel
Louver
Power Cable (Some Units)
Remote Control Remote Control Holder
(Some Units)
Display window (A) fresh defrost run timer
Display window (B) Display window (C) Display window (D) fresh defrost run timer fresh defrost run timer
“ fresh ” when Fresh feature is activated (some units)
“ defrost ” when defrost feature is activated.
“ run ” when the unit is on.
“ timer ” when TIMER is set
“ ” when Wireless Control feature is activated (some units)
“ ” Displays temperature, operation feature and
Error codes:
When ECO function (some units) is activated, the
’ ’ illuminates gradually one by one as --
Display Code
Meanings
-- --set temperature -- ...... in one second interval.
“ ” for 3 seconds when:
● TIMER ON is set (if the unit is OFF, “ ” remains on when TIMER ON is set)
● FRESH, SWING, TURBO, or SILENCE feature is turned on “ ” for
3 seconds when:
● TIMER OFF is set
● FRESH, SWING, TURBO, or SILENCE feature is turned off
“ ” when anti-cold air feature is turned on
“ ” when defrosting (cooling & heating units)
“ ” when unit is self-cleaning (some units)
“ ” when 8ºC heating feature is turned on (some units)
15
Owner’s Manual &
Installation Manual
Operating temperature
When your air conditioner is used outside of the following temperature ranges, certain safety protection features may activate and cause the unit to disable.
Inverter Split Type
Room Temperature
Outdoor
Temperature
COOL mode
17°C - 32°C
(62°F - 90°F)
0°C - 50°C
(32°F - 122°F)
-15°C - 50°C
(5°F - 122°F)
(For models with low temp. cooling systems.)
HEAT mode
0°C - 30°C
(32°F - 86°F)
-15°C - 30°C
(5°F - 86°F)
DRY mode
10°C - 32°C
(50°F - 90°F)
0°C - 50°C
(32°F - 122°F)
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
When outside temperature is below
0°C (32°F), we strongly recommend keeping the unit plugged in at all time to ensure smooth ongoing performance.
0°C - 52°C
(32°F - 126°F)
(For special tropical models)
0°C - 52°C
(32°F - 126°F)
(For special tropical models)
Fixed-speed Type
COOL mode HEAT mode DRY mode
Room
Temperature
17°C-32°C (62°F-90°F)
0°C-30°C
(32°F-86°F)
10°C-32°C (50°F-90°F)
Outdoor
Temperature
18°C-43°C (64°F-109°F)
-7°C-43°C (19°F-1 09°F)
(For models with low-temp cooling systems)
-7°C-24°C
(19°F-75°F)
11°C-43°C (52°F-109°F)
18°C-43°C (64°F-109°F)
18°C-52°C (64°F-1 26°F)
(For special tropical models)
18°C-52°C (64°F-1 26°F)
(For special tropical models)
NOTE: Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
To further optimize the performance of your unit, do the following:
● Keep doors and windows closed.
● Limit energy usage by using TIMER ON and TIMER OFF functions.
● Do not block air inlets or outlets.
● Regularly inspect and clean air filters.
16
Owner’s Manual &
Installation Manual
A guide on using the infrared remote is not included in this literature package. Not all the functions are available for the air conditioner, please check the indoor display and remote control of the unit you purchased.
Other Features
● Auto-Restart (some units)
If the unit loses power, it will automatically restart with the prior settings once power has been restored.
● Anti-mildew (some units)
When turning off the unit from COOL, AUTO
(COOL), or DRY modes, the air conditioner will continue operate at very low power to dry up condensed water and prevent mildew growth.
● Wireless Control (some units)
Wireless control allows you to control your air conditioner using your mobile phone and a wireless connection.
For the USB device access, replacement, maintenance operations must be carried out by professional staff.
● Louver Angle Memory (some units)
When turning on your unit, the louver will automatically resume its former angle.
● Refrigerant Leakage Detection (some units)
The indoor unit will automatically display “EC” or “EL0C”or flash LEDS (model dependent ) when it detects refrigerant leakage.
● Sleep Operation
The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control.
And the Sleep function is not available in FAN or
DRY mode.
Press the SLEEP button when you are ready to go to sleep. When in COOL mode, the unit will increase the temperature by 1°C (2°F) after 1 hour, and will increase an additional 1°C (2°F) after another hour.
When in HEAT mode, the unit will decrease the temperature by 1°C (2°F) after 1 hour, and will decrease an additional 1°C (2°F) after another hour.
The sleep feature will stop after 8 hours and the system will keep running with final situation.
SLEEP Operation
Set temperature
Cool mode (+1°C/2°F) per hour for the first two hours
1hr 1hr
Heat mode (-1°C/2°F) per hour for the first two hours
Keep running
Saving energy during sleep
17
Owner’s Manual &
Installation Manual
Setting Angle of Air Flow
● Setting vertical angle of air fl ow
While the unit is on, use the SWING/DIRECT button on remote control to set the direction
(vertical angle) of airflow. Please refer to the Re mote Control Manual for details.
● NOTE ON LOUVER ANGLES
When using COOL or DRY mode, do not set louver at too vertical an angle for long periods of time. This can cause water to condense on the louver blade, which will drop on your floor or furnishings.
When using COOL or HEAT mode, setting the louver at too vertical an angle can reduce the performance of the unit due to restricted air flow.
● Setting horizontal angle of air flow
The horizontal angle of the airflow must be set manually. Grip the deflector rod (See Fig.B
) and manually adjust it to your preferred direction.
For some units, the horizontal angle of the airflow can be set by remote control. please refer to the
Remote Control Manual.
Range
NOTE: Do not move louver by hand. This will cause the louver to become out of sync. If this occurs, turn off the unit and unplug it for a few seconds, then restart the unit. This will reset the louver.
Fig. A
CAUTION
Do not put your fingers in or near the blower and suction side of the unit. The high-speed fan inside the unit may cause injury.
Manual Operation (without remote)
Deflector rod
CAUTION
The manual button is intended for testing purposes and emergency operation only. Please do not use this function unless the remote control is lost and it is absolutely necessary. To restore regular operation, use the remote control to activate the unit. Unit must be turned off before manual operation.
To operate your unit manually:
1. Open the front panel of the indoor unit.
2. Locate the MANUAL CONTROL button on the right-hand side of the unit.
3. Press the MANUAL CONTROL button one time to activate FORCED AUTO mode.
4. Press the MANUAL CONTROL button again to activate FORCED COOLING mode.
5. Press the MANUAL CONTROL button a third time to turn the unit off.
6. Close the front panel.
Fig. B
Manual control button
18
Owner’s Manual &
Installation Manual
Care and Maintenance
Cleaning Your Indoor Unit
BEFORE CLEANING OR
MAINTENANCE
A LWAYS TURN OFF YOUR AIR
CONDITIONER SYSTEM AND DISCONNECT
ITS POWER SUPPLY BEFORE CLEANING
OR MAINTENANCE.
6.
Rinse the filter with fresh water, then shake off excess water.
7. Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
8.
When dry, re-clip the air freshening filter to the larger filter, then slide it back into the indoor unit.
9. Close the front panel of the indoor unit.
CAUTION
Only use a soft, dry cloth to wipe the unit clean.
If the unit is especially dirty, you can use a cloth soaked in warm water to wipe it clean.
● Do not use chemicals or chemically treated cloths to clean the unit
● Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit.
They can cause the plastic surface to crack or deform.
● Do not use water hotter than 40°C (104°F) to clean the front panel. This can cause the panel to deform or become discolored.
Filter Tab
Cleaning Your Air Filter
A clogged air conditioner can reduce the cooling efficiency of your unit, and can also be bad for your health. Make sure to clean the filter once every two weeks.
1. Lift the front panel of the indoor unit.
2.
First press the tab on the end of filter to loosen the buckle, lift it up, then pull it towards yourself.
3.
Now pull the filter out.
4.
If your filter has a small air freshening filter, unclip it from the larger filter. Clean this air freshening filter with a hand-held vacuum.
5.
Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.
Remove air freshening filter from back of larger filter (some units)
CAUTION
Do not touch air freshening (Plasma) filter for at least 10 minutes after turning off the unit.
19
Owner’s Manual &
Installation Manual
CAUTION
● Before changing the filter or cleaning, turn off the unit and disconnect its power supply.
● When removing filter, do not touch metal parts in the unit. The sharp metal edges can cut you.
● Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause electrical shock.
● Do not expose filter to direct sunlight when drying. This can shrink the filter.
Air Filter Reminders (Optional)
Air Filter Cleaning Reminder
After 240 hours of use, the display window on the indoor unit will flash “CL.” This is a reminder to clean your filter. After 15 seconds, the unit will revert to its previous display.
To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL
CONTROL button 3 times. If you don’t reset the reminder, the “CL” indicator will flash again when you restart the unit.
Maintenance – Long Periods of Non-Use
If you plan not to use your air conditioner for an extended period of time, do the following:
Clean all filters
Turn off the unit and disconnect the power
Turn on FAN function until unit dries out completely
Remove batteries from remote control
Maintenance – Pre-Season Inspection
After long periods of non-use, or before periods of frequent use, do the following:
Air Filter Replacement Reminder
After 2,880 hours of use, the display window on the indoor unit will flash “nF.” This is a reminder to replace your filter. After 15 seconds, the unit will revert to its previous display.
To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL
CONTROL button 3 times. If you don’t reset the reminder, the “nF” indicator will flash again when you restart the unit.
Check for damaged wires Clean all filters
CAUTION
● Any maintenance and cleaning of outdoor unit should be performed by an authorized dealer or a licensed service provider.
● Any unit repairs should be performed by an authorized dealer or a licensed service provider.
Check for leaks Replace batteries
Make sure nothing is blocking all air inlets and outlets
20
Owner’s Manual &
Installation Manual
Troubleshooting
SAFETY PRECAUTIONS
If ANY of the following conditions occurs, turn off your unit immediately!
● The power cord is damaged or abnormally warm
● You smell a burning odor
● The unit emits loud or abnormal sounds
● A power fuse blows or the circuit breaker frequently trips
● Water or other objects fall into or out of the unit
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED
SERVICE PROVIDER IMMEDIATELY!
Common Issues
The following problems are not a malfunction and in most situations will not require repairs.
Issue Possible Causes
Unit does not turn on when pressing ON/OFF button
The unit changes from
COOL/HEAT mode to
FAN mode
The Unit has a 3-minute protection feature that prevents the unit from overloading.
The unit cannot be restarted within three minutes of being turned off.
The unit may change its setting to prevent frost from forming on the unit.
Once the temperature increases, the unit will start operating in the previously selected mode again.
The set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctuates again.
The indoor unit emits white mist
Both the indoor and outdoor units emit white mist
The indoor unit makes noises
Both the indoor unit and outdoor unit make noises
In humid regions, a large temperature difference between the room’s air and the conditioned air can cause white mist.
When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process.
A rushing air sound may occur when the louver resets its position.
A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts.
Low hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises.
21
Owner’s Manual &
Installation Manual
Issue
The outdoor unit makes noises
Dust is emitted from either the indoor or outdoor unit
Possible Causes
The unit will make different sounds based on its current operating mode.
The unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by covering the unit during long periods of inactivity.
The unit emits a bad odor
The unit may absorb odors from the environment (such as furniture, cooking, cigarettes, etc.) which will be emitted during operations.
The unit’s filters have become moldy and should be cleaned.
The fan of the outdoor unit does not operate
During operation, the fan speed is controlled to optimize product operation.
Operation is erratic, unpredictable, or unit is unresponsive
Interference from cell phone towers and remote boosters may cause the unit to malfunction.
In this case, try the following:
● Disconnect the power, then reconnect.
● Press ON/OFF button on remote control to restart operation.
NOTE: If problem persists, contact a local dealer or your nearest customer service center. Provide them with a detailed description of the unit malfunction as well as your model number.
Troubleshooting
When troubles occur, please check the following points before contacting a repair company.
Problem Possible Causes Solution
Temperature setting may be higher than ambient room temperature
The heat exchanger on the indoor or outdoor unit is dirty
The air filter is dirty
Lower the temperature setting
Clean the affected heat exchanger
Poor Cooling
Performance
The air inlet or outlet of either unit is blocked
Doors and windows are open
Excessive heat is generated by sunlight
Remove the filter and clean it according to instructions
Turn the unit off, remove the obstruction and turn it back on
Make sure that all doors and windows are closed while operating the unit
Close windows and curtains during periods of high heat or bright sunshine
Too many sources of heat in the room
(people, computers, electronics, etc.)
Low refrigerant due to leak or long-term use
SILENCE function is activated
(optional function)
Reduce amount of heat sources
Check for leaks, re-seal if necessary and top off refrigerant
SILENCE function can lower product performance by reducing operating frequency. Turn off SILENCE function.
22
Owner’s Manual &
Installation Manual
Problem
The unit is not working
The unit starts and stops frequently
Possible Causes
Power failure
The power is turned off
The fuse is burned out
Remote control batteries are dead
The Unit’s 3-minute protection has been activated
Timer is activated
There’s too much or too little refrigerant in the system
Incompressible gas or moisture has entered the system.
The compressor is broken
The voltage is too high or too low
Solution
Wait for the power to be restored
Turn on the power
Replace the fuse
Replace batteries
Wait three minutes after restarting the unit
Turn timer off
Check for leaks and recharge the system with refrigerant.
Evacuate and recharge the system with refrigerant
Replace the compressor
Install a manostat to regulate the voltage
Use auxiliary heating device
Poor heating performance
The outdoor temperature is extremely low
Cold air is entering through doors and windows
Low refrigerant due to leak or long-term use
Make sure that all doors and windows are closed during use
Check for leaks, re-seal if necessary and top off refrigerant
Indicator lamps continue flashing
Error code appears and begins with the letters as the following in the window display of indoor unit:
● E (x), P (x), F (x)
● EH (xx), EL (xx), EC
(xx)
● PH (xx), PL (xx), PC
(xx)
The unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself.
If not, disconnect the power, then connect it again. Turn the unit on.
If the problem persists, disconnect the power and contact your nearest customer service center.
NOTE: If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact an authorized service center.
23
Owner’s Manual &
Installation Manual
Accessories
The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock and fire, or cause the equipment to fail. The items are not included with the air conditioner must be purchased separately.
Name of Accessories Q’ty (pc) Shape
Name of
Accessories
Q’ty (pc) Shape
Manual 2-3
1
15cm (5.9in)
2.3m (90.55in)
2
5
3
6
7 8
9
STEP
Remote controller 1
Drain joint
(for cooling & heating models)
Seal
(for cooling & heating models)
Mounting plate
1
1
1
Anchor
Mounting plate fixing screw
5~8
(depending on models)
5~8
(depending on models)
Battery 2
Remote controller holder (optional)
Fixing screw for remote controller holder (optional)
1
2
Small Filter
(Need to be installed on the back of main air filter by the authorized technician while installing the machine)
1~2
(depending on models)
Name
Connecting pipe assembly
Liquid side
Gas side
Shape
ø6.35 (1/4 in) - 12K, 18K
ø9.52 (3/8in) - 24K, 30K
ø12.7 (1/2in) - 12K, 18K
ø15.9 (5/8in) - 18K, 24K
ø19.0 (3/4in) - 30K
Quantity (PC)
Parts you must purchase separately. Consult the dealer about the proper pipe size of the unit you purchased.
Magnetic ring and belt
(if supplied ,please refer to the wiring diagram to instal it on the connective cable.)
Pass the belt through the hole of the Magnetic ring to fix it on the cable
Varies by model
24
Owner’s Manual &
Installation Manual
Packing and Unpacking
Indoor unit
Packing the unit as below procedure
1 Put the indoor unit onto the packing case.
2 Assemble cushion-both side of indoor unit. (Left and Right)
3 Seal the packing case.
Unpacking the unit as below procedure
1 Open the packing case.
2 Take out the both side of cushion(Left and Right).
3 Move the set from the packing case.
Outdoor unit
Packing the unit as below procedure
1 Put the outdoor unit onto the cushion-bottom.
2 Put the cushion-top onto the outdoor unit
3 Put the packing case from the top of set.
4 Seal the packing case.
Unpacking the unit as below procedure
1 Take out the packing case from the set.
2 Take out the cushion-top.
3 Move the set from the cushion-bottom
25
1
Installation Summary - Indoor Unit
2 3
12cm
(4.75in)
12cm
(4.75in)
Owner’s Manual &
Installation Manual
Select Installation Location Determine Wall Hole Position
5 6
Attach Mounting Plate
7
Drill Wall Hole
8
Connect Piping Connect Wiring
(not applicable for some locations in the US )
Prepare Drain Hose
Wrap Piping and Cable
(not applicable for some locations in the US)
9
STEP
8
Mount Indoor Unit
26
Owner’s Manual &
Installation Manual
Unit Parts
NOTE: The installation must be performed in accordance with the requirement of local and national standards. The installation may be slightly different in different areas.
1
1
Air-break switch
3
4
2
2
4
3
6
5
7
8
5
6
7
8
9 10
11 11
(1) (2)
Wall Mounting Plate
Front Panel
Power Cable (Some Units)
Louver
Functional Filter (On Back of Main Filter - Some
Units)
Drainage Pipe
Signal Cable
Refrigerant Piping
Remote Controller
Remote controller Holder
(Some Units)
Outdoor Unit Power Cable
(Some Units)
NOTE ON ILLUSTRATIONS
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail.
27
Owner’s Manual &
Installation Manual
Indoor Unit Installation
Installation Instructions – Indoor unit
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to the label on the product box to make sure that the model number of the indoor unit matches the model number of the outdoor unit.
Step 1: Select installation location
Before installing the indoor unit, you must choose an appropriate location. The following are standards that will help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
Good air circulation
Convenient drainage
Noise from the unit will not disturb other people
Firm and solid—the location will not vibrate
Strong enough to support the weight of the unit
A location at least one meter from all other electrical devices (e.g., TV, radio, computer)
DO NOT install unit in the following locations:
Near any source of heat, steam, or combustible gas
Near flammable items such as curtains or clothing
Near any obstacle that might block air circulation
Near the doorway
In a location subject to direct sunlight
NOTE ABOUT WALL HOLE:
If there is no fixed refrigerant piping:
While choosing a location, be aware that you should leave ample room for a wall hole
(see Drill wall hole for connective piping step) for the signal cable and refrigerant piping that connect the indoor and outdoor units. The default position for all piping is the right side of the indoor unit (while facing the unit). However, the unit can accommodate piping to both the left and right.
Refer to the following diagram to ensure proper distance from walls and ceiling:
15cm (5.9in) or more
12cm (4.75in) or more
12cm (4.75in) or more
2.3m (90.55in) or more
Step 2: Attach mounting plate to wall
The mounting plate is the device on which you will mount the indoor unit.
● Take out the mounting plate at the back of the indoor unit.
● Secure the mounting plate to the wall with the screws provided. Make sure that mounting plate is flat against the wall.
NOTE FOR CONCRETE OR BRICK
WALLS:
If the wall is made of brick, concrete, or similar material, drill 5mm-diameter (0.2indiameter) holes in the wall and insert the sleeve anchors provided. Then secure the mounting plate to the wall by tightening the screws directly into the clip anchors.
28
Owner’s Manual &
Installation Manual
Step 3: Drill wall hole for connective piping
1. Determine the location of the wall hole based on the position of the mounting plate. Refer to Mounting Plate
Dimensions .
2. Using a 65mm (2.5in) or 90mm (3.54in)
(depending on models )core drill, drill a hole in the wall. Make sure that the hole is drilled at a slight downward angle, so that the outdoor end of the hole is lower than the indoor end by about 5mm to 7mm (0.2-0.275in). This will ensure proper water drainage.
3. Place the protective wall cuff in the hole. This protects the edges of the hole and will help seal it when you finish the installation process.
Type A
148mm (5.8in)
Type B
402mm (15.8in)
237mm (9.3in)
Left rear wall hole
65mm (2.5in)
45mm (1.7in) 103mm (4.1in)
715mm (28in)
Model A
130mm (5.1in) 107mm (4.2in)
Indoor unit outline
Right rear wall hole
65mm (2.5in)
CAUTION
When drilling the wall hole, make sure to avoid wires, plumbing, and other sensitive components.
Wall
Indoor Outdoor
230mm (9.1in)
Left rear wall hole
65mm (2.5in)
45mm (1.7in) 185mm (7.3in)
805mm (31.7in)
Model B
411mm (16.2in)
246mm (9.7in)
139mm (5.5in) 107mm (4.2in)
Indoor unit outline
Right rear wall hole
65mm (2.5in)
285mm (11.2in)
458mm (18in)
243mm (9.57in)
Left rear wall hole
65mm (2.5in)
45mm (1.7in) 240mm (9.5in)
958.3mm (37.7in)
Model C
143mm (5.6in) 100mm (3.9in)
Indoor unit outline
Right rear wall hole
65mm (2.5in)
264mm (10.4in)
559mm (22in)
344mm (13.5in)
MOUNTING PLATE DIMENSIONS
Different models have different mounting plates.
For the different customization requirements, the shape of the mounting plate may be slightly different. But the installation dimensions are the same for the same size of indoor unit.
See Type A and Type B for example:
Correct orientation of Mounting Plate
Left rear wall hole
65mm (2.5in)
219mm (8.6in) 299mm (11.8in)
1037.6mm (40.85in)
Model D
45mm
(1.77in)
Right rear wall hole
65mm (2.5in)
NOTE: When the gas side connective pipe is ø16mm (5/8in) or more, the wall hole should be 90mm (3.54in).
29
Owner’s Manual &
Installation Manual
Step 4: Prepare refrigerant piping
The refrigerant piping is inside an insulating sleeve attached to the back of the unit. You must prepare the piping before passing it through the hole in the wall.
1. Based on the position of the wall hole relative to the mounting plate, choose the side from which the piping will exit the unit.
2. If the wall hole is behind the unit, keep the knock-out panel in place. If the wall hole is to the side of the indoor unit, remove the plastic knock-out panel from that side of the unit. This will create a slot through which your piping can exit the unit. Use needle nose pliers if the plastic panel is too difficult to remove by hand.
Step 5: Connect drain hose
By default, the drain hose is attached to the lefthand side of unit (when you’re facing the back of the unit). However, it can also be attached to the right-hand side. To ensure proper drainage, attach the drain hose on the same side that your refrigerant piping exits the unit. Attach drain hose extension (purchased separately) to the end of drain hose.
● Wrap the connection point firmly with
Teflon tape to ensure a good seal and to prevent leaks.
● For the portion of the drain hose that will remain indoors, wrap it with foam pipe insulation to prevent condensation.
● Remove the air filter and pour a small amount of water into the drain pan to make sure that water flows from the unit smoothly.
Knock-out Panel
3. If existing connective piping is already embedded in the wall, proceed directly to the Connect Drain Hose step. If there is no embedded piping, connect the indoor unit’s refrigerant piping to the connective piping that will join the indoor and outdoor units. Refer to the
Refrigerant Piping Connection section of this manual for detailed instructions.
NOTE ON PIPING ANGLE
Refrigerant piping can exit the indoor unit from four different angles:Left-hand side,Right-hand side, Left rear, Right rear.
NOTE ON DRAIN HOSE
PLACEMENT
Make sure to arrange the drain hose according to the following figures.
CORRECT
Make sure there are no kinks or dent in drain hose to ensure proper drainage.
NOT CORRECT
Kinks in the drain hose will create water traps.
CAUTION
Be extremely careful not to dent or damage the piping while bending them away from the unit. Any dents in the piping will affect the unit’s performance.
NOT CORRECT
Kinks in the drain hose will create water traps.
NOT CORRECT
Do not place the end of the drain hose in water or in containers that collect water.
This will prevent proper drainage.
PLUG THE UNUSED DRAIN HOLE
To prevent unwanted leaks you must plug the unused drain hole with the rubber plug provided.
30
Owner’s Manual &
Installation Manual
BEFORE PERFORMING ANY
ELECTRICAL WORK, READ THESE
REGULATIONS
1. All wiring must comply with local and national electrical codes, regulations and must be installed by a licensed electrician.
2. All electrical connections must be made according to the Electrical Connection
Diagram located on the panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power supply, stop work immediately.
Explain your reasoning to the client, and refuse to install the unit until the safety issue is properly resolved.
4. Power voltage should be within 90-
110% of rated voltage. Insufficient power supply can cause malfunction, electrical shock, or fire.
5. If connecting power to fixed wiring, install a surge protector and main power switch with a capacity of 1.5 times the maximum current of the unit.
6. If connecting power to fixed wiring, a switch or circuit breaker that disconnects all poles and has a contact separation of at least 1/8in (3mm) must be incorporated in the fixed wiring.
The qualified technician must use an approved circuit breaker or switch.
7. Only connect the unit to an individual branch circuit outlet. Do not connect another appliance to that outlet.
8. Make sure to properly ground the air conditioner.
9. Every wire must be firmly connected.
Loose wiring can cause the terminal to overheat, resulting in product malfunction and possible fire.
10. Do not let wires touch or rest against refrigerant tubing, the compressor, or any moving parts within the unit.
11. If the unit has an auxiliary electric heater, it must be installed at least 1 meter (40in) away from any combustible materials.
12. To avoid getting an electric shock, never touch the electrical components soon after the power supply has been turned off. After turning off the power, always wait 10 minutes or more before you touch the electrical components.
WARNING
BEFORE PERFORMING ANY
ELECTRICAL OR WIRING WORK,
TURN OFF THE MAIN POWER TO THE
SYSTEM.
Step 6: Connect signal cable
The signal cable enables communication between the indoor and outdoor units. You must first choose the right cable size before preparing it for connection.
Cable Types
● Indoor Power Cable (if applicable):
H05VV-F or H05V2V2-F
● Outdoor Power Cable: H07RN-F
● Signal Cable: H07RN-F
Minimum Cross-Sectional Area of Power and Signal Cables (For reference)
Rated Current of Appliance (A)
> 3 and ≤ 6
> 6 and ≤ 10
> 10 and ≤ 16
> 16 and ≤ 25
> 25 and ≤ 32
> 32 and ≤ 40
Nominal Cross-Sectional
Area (mm²)
0.75
4
6
1
1.5
2.5
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal cable, fuse, and switch needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the side panel of the unit. Refer to this nameplate to choose the right cable, fuse, or switch.
31
Owner’s Manual &
Installation Manual
1. Open front panel of the indoor unit.
2. Using a screwdriver, open the wire box cover on the right side of the unit. This will reveal the terminal block.
Terminal block
Wire cover
Screw
Cable clamp
NOTE ABOUT WIRING
THE WIRING CONNECTION PROCESS
MAY DIFFER SLIGHTLY BETWEEN UNITS
AND REGIONS.
Step 7: Wrap pipes and cables
Before passing the piping, drain hose, and the signal cable through the wall hole, you must bundle them together to save space, protect them, and insulate them (Not applicable in North America).
1. Bundle the drain hose, refrigerant pipes, and signal cable as shown below:
Indoor Unit
WARNING
ALL WIRING MUST BE PERFORMED
STRICTLY IN ACCORDANCE WITH
THE WIRING DIAGRAM LOCATED ON
THE BACK OF THE INDOOR UNIT’S
FRONT PANEL.
3. Unscrew the cable clamp below the terminal block and place it to the side.
4. Facing the back of the unit, remove the plastic panel on the bottom left-hand side.
5. Feed the signal wire through this slot, from the back of the unit to the front.
6. Facing the front of the unit, connect the wire according to the indoor unit’s wiring diagram, connect the u-lug and firmly screw each wire to its corresponding terminal.
CAUTION
DO NOT MIX UP LIVE AND NULL
WIRES
This is dangerous, and can cause the air conditioning unit to malfunction.
7. After checking to make sure every connection is secure, use the cable clamp to fasten the signal cable to the unit. Screw the cable clamp down tightly.
8. Replace the wire cover on the front of the unit, and the plastic panel on the back.
Space behind
Refrigerant piping
Insulation tape
Signal wire Drain hose
DRAIN HOSE MUST BE ON BOTTOM
Make sure that the drain hose is at the bottom of the bundle. Putting the drain hose at the top of the bundle can cause the drain pan to overflow, which can lead to fire or water damage.
DO NOT INTERTWINE SIGNAL CABLE
WITH OTHER WIRES
While bundling these items together, do not intertwine or cross the signal cable with any other wiring.
2. Using adhesive vinyl tape, attach the drain hose to the underside of the refrigerant pipes.
3. Using insulation tape, wrap the signal wire, refrigerant pipes, and drain hose tightly together. Double-check that all items are bundled.
DO NOT WRAP ENDS OF PIPING
When wrapping the bundle, keep the ends of the piping unwrapped. You need to access them to test for leaks at the end of the installation process (refer to Electrical
Checks and Leak Checks section of this manual).
32
Owner’s Manual &
Installation Manual
Step 8: Mount indoor unit
If you installed new connective piping to the outdoor unit, do the following:
1. If you have already passed the refrigerant piping through the hole in the wall, proceed to Step 4.
2. Otherwise, double-check that the ends of the refrigerant pipes are sealed to prevent dirt or foreign materials from entering the pipes.
3. Slowly pass the wrapped bundle of refrigerant pipes, drain hose, and signal wire through the hole in the wall.
4. Hook the top of the indoor unit on the upper hook of the mounting plate.
5. Check that unit is hooked firmly on mounting by applying slight pressure to the left and right-hand sides of the unit.
The unit should not jiggle or shift.
6. Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps onto the hooks along the bottom of the mounting plate.
7. Again, check that the unit is firmly mounted by applying slight pressure to the left and the right-hand sides of the unit.
If refrigerant piping is already embedded in the wall, do the following:
1. Hook the top of the indoor unit on the upper hook of the mounting plate.
2. Use a bracket or wedge to prop up the unit, giving you enough room to connect the refrigerant piping, signal cable, and drain hose.
3. Connect drain hose and refrigerant piping (refer efer to Refrigerant Piping
Connection section of this manual for instructions).
4. Keep pipe connection point exposed to perform the leak test (refer to Electrical
Checks and Leak Checks section of this manual).
5. After the leak test, wrap the connection point with insulation tape.
6. Remove the bracket or wedge that is propping up the unit.
7. Using even pressure, push down on the bottom half of the unit. Keep pushing down until the unit snaps onto the hooks along the bottom of the mounting plate.
UNIT IS ADJUSTABLE
Keep in mind that the hooks on the mounting plate are smaller than the holes on the back of the unit. If you find that you don’t have ample room to connect embedded pipes to the indoor unit, the unit can be adjusted left or right by about 30-50mm (1.25-1.95in), depending on the model.
30-50mm
(1.2-1.95in)
Move to left or right
30-50mm
(1.2-1.95in)
Wedge
33
Owner’s Manual &
Installation Manual
Outdoor Unit Installation
Install the unit by following local codes and regulations , there may be differ slightly between different regions.
30cm (12in) on left
30cm (12in) from b ack w all
60cm (24in) on right
Installation Instructions – Outdoor unit
Step 1: Select installation location
Before installing the outdoor unit, you must choose an appropriate location. The following are standards that will help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
Meets all spatial requirements shown in
Installation Space Requirements above.
Good air circulation and ventilation
Firm and solid—the location can support the unit and will not vibrate
Noise from the unit will not disturb others
Protected from prolonged periods of direct sunlight or rain
Where snowfall is anticipated, raise the unit above the base pad to prevent ice buildup and coil damage. Mount the unit high enough to be above the average accumulated area snowfall. The minimum height must be 18 inches
DO NOT install unit in the following locations:
Near an obstacle that will block air inlets and outlets
Near a public street, crowded areas, or where noise from the unit will disturb others
Near animals or plants that will be harmed by hot air discharge
Near any source of combustible gas
In a location that is exposed to large amounts of dust
In a location exposed to a excessive amounts of salty air
SPECIAL CONSIDERATIONS FOR
EXTREME WEATHER
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier in front of the unit to protect it from extremely heavy winds.
See Figures below.
Strong wind
Wind
Baffle
Strong wind
Strong wind
If the unit is frequently exposed to heavy rain or snow:
Build a shelter above the unit to protect it from the rain or snow. Be careful not to obstruct air flow around the unit.
If the unit is frequently exposed to salty air (seaside):
Use outdoor unit that is specially designed to resist corrosion.
34
Owner’s Manual &
Installation Manual
Step 2: Install drain joint (Heat pump unit only)
Before bolting the outdoor unit in place, you must install the drain joint at the bottom of the unit. Note that there are two different types of drain joints depending on the type of outdoor unit.
If the drain joint comes with a rubber seal
(see Fig. A ), do the following:
1. Fit the rubber seal on the end of the drain joint that will connect to the outdoor unit.
2. Insert the drain joint into the hole in the base pan of the unit.
3. Rotate the drain joint 90° until it clicks in place facing the front of the unit.
4. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during heating mode.
If the drain joint doesn’t come with a rubber seal (see Fig. B ), do the following:
1. Insert the drain joint into the hole in the base pan of the unit. The drain joint will click in place.
2. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during heating mode.
Step 3: Anchor outdoor unit
The outdoor unit can be anchored to the ground or to a wall-mounted bracket with bolt (M10). Prepare the installation base of the unit according to the dimensions below.
UNIT MOUNTING DIMENSIONS
The following is a list of different outdoor unit sizes and the distance between their mounting feet. Prepare the installation base of the unit according to the dimensions below.
A
Air inlet
Air inlet
Air outlet
H
W
Seal
Base pan hole of outdoor unit
Seal
Drain joint
(A) (B)
IN COLD CLIMATES
In cold climates, make sure that the drain hose is as vertical as possible to ensure swift water drainage. If water drains too slowly, it can freeze in the hose and flood the unit.
35
Owner’s Manual &
Installation Manual
Outdoor Unit Dimensions (mm)
W × H × D
681 × 434 × 285 (26.8” × 17.1” × 11.2”)
700 × 550 × 270 (27.5” × 21.6” × 10.6”)
700 × 550 × 275 (27.5” × 21.6” × 10.8”)
720 × 495 × 270 (28.3” × 19.5” × 10.6”)
728 × 555 × 300 (28.7” × 21.8” × 11.8”)
765 × 555 × 303 (30.1” × 21.8” × 11.9”)
770 × 555 × 300 (30.3” × 21.8” × 11.8”)
805 × 554 × 330 (31.7” × 21.8” × 12.9”)
800 × 554 × 333 (31.5” × 21.8” × 13.1”)
845 × 702 × 363 (33.3” × 27.6” × 14.3”)
890 × 673 × 342 (35.0” × 26.5” × 13.5”)
946 × 810 × 420 (37.2” × 31.9” × 16.5”)
946 × 810 × 410 (37.2” × 31.9” × 16.1”)
If you will install the unit on the ground or on a concrete mounting platform, do the following:
1. Mark the positions for four expansion bolts based on dimensions chart.
2. Pre-drill holes for expansion bolts.
3. Place a nut on the end of each expansion bolt.
4. Hammer expansion bolts into the predrilled holes.
5.
Remove the nuts from expansion bolts, and place outdoor unit on bolts.
6.
Put washer on each expansion bolt, then replace the nuts.
7.
Using a wrench, tighten each nut until snug.
WARNING
WHEN DRILLING INTO CONCRETE,
EYE PROTECTION IS RECOMMENDED
AT ALL TIMES.
Mounting Dimensions
Distance A (mm) Distance B (mm)
460 (18.1”)
450 (17.7”)
450 (17.7”)
452 (17.7”)
452 (17.8”)
452 (17.8”)
487 (19.2”)
511 (20.1”)
514 (20.2”)
540 (21.3”)
663 (26.1”)
673 (26.5”)
673 (26.5”)
292 (11.5”)
292 (10.2”)
260 (10.2”)
255 (10.0”)
302 (11.9”)
286 (11.3”)
298 (11.7”)
317 (12.5”)
340 (13.4”)
350 (13.8”)
354 (13.9”)
403 (15.9”)
403 (15.9”)
If you will install the unit on a wallmounted bracket, do the following:
CAUTION
Make sure that the wall is made of solid brick, concrete, or of similarly strong material. The wall must be able to support at least four times the weight of the unit.
1. Mark the position of bracket holes based on dimensions chart.
2. Pre-drill the holes for the expansion bolts.
3.
Place a washer and nut on the end of each expansion bolt.
4. Thread expansion bolts through holes in mounting brackets, put mounting brackets in position, and hammer expansion bolts into the wall.
5. Check that the mounting brackets are level.
6. Carefully lift unit and place its mounting feet on brackets.
7.
Bolt the unit firmly to the brackets.
8.
If allowed, install the unit with rubber gaskets to reduce vibrations and noise.
36
Owner’s Manual &
Installation Manual
Step 4: Connect signal and power cables
The outside unit’s terminal block is protected by an electrical wiring cover on the side of the unit. A comprehensive wiring diagram is printed on the inside of the wiring cover.
WARNING
BEFORE PERFORMING ANY
ELECTRICAL OR WIRING WORK,
TURN OFF THE MAIN POWER TO THE
SYSTEM.
1.
Prepare the cable for connection:
USE THE RIGHT CABLE
● Indoor Power Cable (if applicable):
H05VV-F or H05V2V2-F
● Outdoor Power Cable: H07RN-F
● Signal Cable: H07RN-F
2.
Unscrew the electrical wiring cover and remove it.
3.
Unscrew the cable clamp below the terminal block and place it to the side.
4.
Connect the wire according to the wiring diagram, and firmly screw the u-lug of each wire to its corresponding terminal.
5.
After checking to make sure every connection is secure, loop the wires around to prevent rain water from flowing into the terminal.
6.
Using the cable clamp, fasten the cable to the unit. Screw the cable clamp down tightly.
7.
Insulate unused wires with PVC electrical tape. Arrange them so that they do not touch any electrical or metal parts.
8.
Replace the wire cover on the side of the unit, and screw it in place.
Cover
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal cable, fuse, and switch needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the side panel of the unit. Refer to this nameplate to choose the right cable, fuse, or switch. a. Using wire strippers, strip the rubber jacket from both ends of cable to reveal about 40mm (1.57in) of the wires inside.
b. Strip the insulation from the ends of the wires.
c. Using a wire crimper, crimp u-lugs on the ends of the wires.
PAY ATTENTION TO LIVE WIRE
While crimping wires, make sure you clearly distinguish the Live (“L”) Wire from other wires.
In North America
Screw
1.
Remove the wire cover from the unit by loosening the 3 screws.
2. Dismount caps on the conduit panel.
3. Temperarily mount the conduit tubes (not included) on the conduit panel.
4.
Properly connect both the power supply and low voltage lines to the corresponding terminals on the terminal block.
5.
Ground the unit in accordance with local codes.
6.
Be sure to size each wire allowing several inches longer than the required length for wiring.
7.
Use lock nuts to secure the conduit tubes.
WARNING
ALL WIRING WORK MUST BE
PERFORMED STRICTLY IN
ACCORDANCE WITH THE WIRING
DIAGRAM LOCATED INSIDE OF WIRE
COVER OF THE OUTDOOR UNIT.
37
Terminal block
Over 1.57in. (40mm)
G
Connecting cable
Power supply cord
Conduit panel
Wire Cover
Please select the appropriate through-hole according to the diameter of the wire.
Owner’s Manual &
Installation Manual
Refrigerant Piping Connection
When connecting refrigerant piping, do not let substances or gases other than the specified refrigerant enter the unit. The presence of other gases or substances will lower the unit’s capacity, and can cause abnormally high pressure in the refrigeration cycle. This can cause explosion and injury.
Note on Pipe Length
The length of refrigerant piping will affect the performance and energy efficiency of the unit. Nominal efficiency is tested on units with a pipe length of 5 meters (16.5ft) (In North
America, the standard pipe length is 7.5m (25’). A minimum pipe run of 3 metres is required to minimise vibration & excessive noise. In special tropical area, for the R290 refrigerant models, no refrigerant can be added and the maximum length of refrigerant pipe should not exceed 10 meters (32.8ft).
Refer to the table below for specifications on the maximum length and drop height of piping.
Maximum Length and Drop Height of Refrigerant Piping per Unit Model
Model
R410A Fixed-speed
Split Air Conditioner
Capacity (BTU/h) Max. Length (m) Max. Drop Height (m)
< 18,000
≥ 18,000 and < 36,000
20 (66ft)
25 (82ft)
8 (26ft)
10 (33ft)
Connection Instructions – Refrigerant Piping
Step 1: Cut pipes
When preparing refrigerant pipes, take extra care to cut and flare them properly. This will ensure efficient operation and minimize the need for future maintenance.
1.
Measure the distance between the indoor and outdoor units.
2.
Using a pipe cutter, cut the pipe a little longer than the measured distance.
3. Make sure that the pipe is cut at a perfect 90° angle.
90° Oblique Rough Warped
DO NOT DEFORM PIPE WHILE
CUTTING
Be extra careful not to damage, dent, or deform the pipe while cutting. This will drastically reduce the heating efficiency of the unit.
38
Owner’s Manual &
Installation Manual
Step 2: Remove burrs
Burrs can affect the air-tight seal of refrigerant piping connection. They must be completely removed.
1.
Hold the pipe at a downward angle to prevent burrs from falling into the pipe.
2.
Using a reamer or deburring tool, remove all burrs from the cut section of the pipe.
Pipe
Reamer
PIPING EXTENSION BEYOND FLARE
FORM
Outer Diameter of Pipe (mm) Min.
A (mm)
Max.
ø6.35 (ø0.25”) 0.7 (0.0275”) 1.3 (0.05”)
ø9.52 (ø0.375”) 1.0 (0.04”) 1.6 (0.063”)
ø12.7 (ø0.5”) 1.0 (0.04”) 1.8 (0.07”)
ø16 (ø0.63”) 2.0 (0.078”) 2.2 (0.086”)
ø19 (ø0.75”) 2.0 (0.078”) 2.4 (0.094”)
Point down
Flare form
Step 3: Flare pipe ends
Proper flaring is essential to achieve an airtight seal.
1.
After removing burrs from cut pipe, seal the ends with PVC tape to prevent foreign materials from entering the pipe.
2.
Sheath the pipe with insulating material.
3.
Place flare nuts on both ends of pipe.
Make sure they are facing in the right direction, because you can’t put them on or change their direction after flaring.
Flare nut
Copper pipe
Pipe
6.
Place flaring tool onto the form.
7.
Turn the handle of the flaring tool clockwise until the pipe is fully flared.
8.
Remove the flaring tool and flare form, then inspect the end of the pipe for cracks and even flaring.
Step 4: Connect pipes
When connecting refrigerant pipes, be careful not to use excessive torque or to deform the piping in any way. You should first connect the low-pressure pipe, then the high-pressure pipe.
MINIMUM BEND RADIUS
When bending connective refrigerant piping, the minimum bending radius is 10cm.
4.
Remove PVC tape from ends of pipe when ready to perform flaring work.
5.
Clamp flare form on the end of the pipe.
The end of the pipe must extend beyond the edge of the flare form in accordance with the dimensions shown in the table below.
Radius ≥10cm (4in)
Instructions for Connecting Piping to
Indoor Unit
1.
Align the center of the two pipes that you will connect.
Indoor unit tubing Flare nut Pipe
39
Owner’s Manual &
Installation Manual
2.
Tighten the flare nut as tightly as possible by hand.
3.
Using a spanner, grip the nut on the unit tubing.
4.
While firmly gripping the nut on the unit tubing, use a torque wrench to tighten the flare nut according to the torque values in the Torque Requirements table below. Loosen the flaring nut slightly, then tighten again.
TORQUE REQUIREMENTS
Outer Diameter of
Pipe (mm)
ø6.35 (ø0.25”)
ø9.52 (ø0.375”)
ø12.7 (ø0.5”)
ø16 (ø0.63”)
ø19 (ø0.75”)
Tightening Torque
(N•m)
Flare dimension (B)
(mm)
18~20 (180~ 200kgf.cm) 8.4~8.7 (0.33~ 0.34”)
32~39 (320~ 390kgf.cm) 13.2~13.5 (0.52~ 0.53”)
49~59 (490~ 590kgf.cm) 16.2~16.5 (0.64~ 0.65”)
57~71 (570~ 710kgf.cm) 19.2~19.7 (0.76~ 0.78”)
67~101 (670~ 1010kgf.cm) 23.2~23.7 (0.91~ 0.93”)
Flare shape
90°±4
45°±2
B
R0.4~0.8
DO NOT USE EXCESSIVE TORQUE
Excessive force can break the nut or damage the refrigerant piping. You must not exceed torque requirements shown in the table above.
Instructions for Connecting Piping to Outdoor Unit
1.
Unscrew the cover from the packed valve on the side of the outdoor unit.
2.
Remove protective caps from ends of valves.
3.
Align flared pipe end with each valve, and tighten the flare nut as tightly as possible by hand.
4.
Using a spanner, grip the body of the valve. Do not grip the nut that seals the service valve.
6.
Loosen the flaring nut slightly, then tighten again.
7. Repeat Steps 3 to 6 for the remaining pipe.
USE SPANNER TO GRIP MAIN
BODY OF VALVE
Torque from tightening the flare nut can snap off other parts of valve.
Valve cover
5.
While firmly gripping the body of the valve, use a torque wrench to tighten the flare nut according to the correct torque values.
40
Owner’s Manual &
Installation Manual
Air Evacuation
Preparations and Precautions
Air and foreign matter in the refrigerant circuit can cause abnormal rises in pressure, which can damage the air conditioner, reduce its efficiency, and cause injury. Use a vacuum pump and manifold gauge to evacuate the refrigerant circuit, removing any non-condensable gas and moisture from the system.
Evacuation should be performed upon initial installation and when unit is relocated.
BEFORE PERFORMING EVACUATION
Check to make sure the connective pipes between the indoor and outdoor units are connected properly.
Check to make sure all wiring is connected properly.
Evacuation Instructions
1. Connect the charge hose of the manifold gauge to service port on the outdoor unit’s low pressure valve.
2. Connect another charge hose from the manifold gauge to the vacuum pump.
3.
Open the Low Pressure side of the manifold gauge. Keep the High Pressure side closed.
4.
Turn on the vacuum pump to evacuate the system.
5.
Run the vacuum for at least 15 minutes, or until the Compound Meter reads
-76cmHG (-10 5 Pa).
Manifold Gauge
Compound gauge
-76cmHg
Low pressure valve
Pressure hose/
Charge hose
High pressure valve
Charge hose
Vacuum pump
7. Wait for 5 minutes, then check that there has been no change in system pressure.
8. If there is a change in system pressure, refer to Gas Leak Check section for information on how to check for leaks. If there is no change in system pressure, unscrew the cap from the packed valve
(high pressure valve).
9.
Insert hexagonal wrench into the packed valve (high pressure valve) and open the valve by turning the wrench in a 1/4 counterclockwise turn. Listen for gas to exit the system, then close the valve after 5 seconds.
10. Watch the Pressure Gauge for one minute to make sure that there is no change in pressure. The Pressure
Gauge should read slightly higher than atmospheric pressure.
11.
Remove the charge hose from the service port.
Flare nut valve body valve stem
Cap
12.
Using hexagonal wrench, fully open both the high pressure and low pressure valves.
13.
Tighten valve caps on all three valves
(service port, high pressure, low pressure) by hand. You may tighten it further using a torque wrench if needed.
OPEN VALVE STEMS GENTLY
Low pressure valve
6.
Close the Low Pressure side of the manifold gauge, and turn off the vacuum pump.
When opening valve stems, turn the hexagonal wrench until it hits against the stopper. Do not try to force the valve to open further.
41
Owner’s Manual &
Installation Manual
Note on Adding Refrigerant
Some systems require additional charging depending on pipe lengths. The standard pipe length varies according to local regulations. For example, in North America, the standard pipe length is 7.5m (25’). In other areas, the standard pipe length is 5m (16’). The refrigerant should be charged from the service port on the outdoor unit’s low pressure valve.
The additional refrigerant to be charged can be calculated using the following formula:
ADDITIONAL REFRIGERANT PER PIPE LENGTH
Connective Pipe
Length (m)
Air Purging
Method
≤ Standard pipe length
Vacuum Pump
Additional Refrigerant
N/A
> Standard pipe length
Vacuum Pump
Liquid Side: ø6.35 (ø0.25”)
R32:
(Pipe length – standard length) × 12g/m
(Pipe length – standard length) × 0.13oZ/ft
R290:
(Pipe length – standard length) × 10g/m
(Pipe length – standard length) × 0.10oZ/ft
R410A:
(Pipe length – standard length) × 15g/m
(Pipe length – standard length) × 0.16oZ/ft
R22:
(Pipe length – standard length) × 20g/m
(Pipe length – standard length) × 0.21oZ/ft
Liquid Side: ø9.52 (ø0.375”)
R32:
(Pipe length – standard length) × 24g/m
(Pipe length – standard length) × 0.26oZ/ft
R290:
(Pipe length – standard length) × 18g/m
(Pipe length – standard length) × 0.19oZ/ft
R410A:
(Pipe length – standard length) × 30g/m
(Pipe length – standard length) × 0.32oZ/ft
R22:
(Pipe length – standard length) × 40g/m
(Pipe length – standard length) × 0.42oZ/ft
For R290 refrigerant unit, the total amount of refrigerant to be charged is no more than:
387g (<=9000Btu/h), 447g (>9000Btu/h and <=12000Btu/h), 547g (>12000Btu/h and
<=18000Btu/h), 632g (>18000Btu/h and <=24000Btu/h).
CAUTION
DO NOT mix refrigerant types.
42
Owner’s Manual &
Installation Manual
Electrical and Gas Leak Checks
Before Test Run
Only perform test run after you have completed the following steps:
● Electrical Safety Checks – Confirm that the unit’s electrical system is safe and operating properly
● Gas Leak Checks – Check all flare nut connections and confirm that the system is not leaking
● Confirm that gas and liquid (high and low pressure) valves are fully open
Electrical Safety Checks
After installation, confirm that all electrical wiring is installed in accordance with local and national regulations, and according to the Installation Manual.
BEFORE TEST RUN
Check Grounding Work
Measure grounding resistance by visual detection and with grounding resistance tester. Grounding resistance must be less than 0.1Ω.
Note: This may not be required for some locations in the US.
DURING TEST RUN
Check for Electrical Leakage
During the Test Run , use an electroprobe and multimeter to perform a comprehensive electrical leakage test.
If electrical leakage is detected, turn off the unit immediately and call a licensed electrician to find and resolve the cause of the leakage.
Note: This may not be required for some locations in the US.
WARNING – RISK OF ELECTRIC
SHOCK
ALL WIRING MUST COMPLY WITH
LOCAL AND NATIONAL ELECTRICAL
CODES, AND MUST BE INSTALLED BY A
LICENSED ELECTRICIAN.
Gas Leak Checks
There are two different methods to check for gas leaks.
Soap and Water Method
Using a soft brush, apply soapy water or liquid detergent to all pipe connection points on the indoor unit and outdoor unit. The presence of bubbles indicates a leak.
Leak Detector Method f using leak detector, refer to the device’s operation manual for proper usage instructions.
AFTER PERFORMING GAS LEAK
CHECKS
After confirming that the all pipe connection points DO NOT leak, replace the valve cover on the outside unit.
Check-point of indoor unit
Check-point of outdoor unit
B
A
D
C
A: Low pressure stop valve
B: High pressure stop valve
C& D: Indoor unit flare nuts
43
Owner’s Manual &
Installation Manual
Test Run
Test Run Instructions
You should perform the Test Run for at least
30 minutes.
1. Connect power to the unit.
2. Press the ON/OFF button on the remote controller to turn it on.
3. Press the MODE button to scroll through the following functions, one at a time:
● COOL – Select lowest possible temperature
● HEAT – Select highest possible temperature
4. Let each function run for 5 minutes, and perform the following checks:
List of Checks to
Perform
No electrical leakage
Unit is properly grounded
All electrical terminals properly covered
Indoor and outdoor units are solidly installed
All pipe connection points do not leak
Water drains properly from drain hose
All piping is properly insulated
Unit performs COOL function properly
Unit performs HEAT function properly
Indoor unit louvers rotate properly
Indoor unit responds to remote controller
PASS/FAIL
Outdoor
(2):
Indoor
(2):
DOUBLE-CHECK PIPE CONNECTIONS
During operation, the pressure of the refrigerant circuit will increase. This may reveal leaks that were not present during your initial leak check. Take time during the
Test Run to double-check that all refrigerant pipe connection points do not have leaks.
Refer to Gas Leak Check section for instructions.
5. After the Test Run is successfully completed, and you confirm that all checks points in List of Checks to
Perform have PASSED, do the following: a. Using remote control, return unit to normal operating temperature.
b. Using insulation tape, wrap the indoor refrigerant pipe connections that you left uncovered during the indoor unit installation process.
IF AMBIENT TEMPERATURE IS BELOW
17°C (62°F)
You can’t use the remote controller to turn on the COOL function when the ambient temperature is below 17°C. In this instance, you can use the MANUAL CONTROL button to test the COOL function.
1. Lift the front panel of the indoor unit, and raise it until it clicks in place.
2. The MANUAL CONTROL button is located on the right-hand side of the unit. Press it 2 times to select the COOL function.
3. Perform Test Run as normal.
Manual control button
44
Owner’s Manual &
Installation Manual
Impedance Information
(Applicable to the following units only)
This appliance MSAFB-12HRN1-QC6 can be connected only to a supply with system impedance no more than 0.373Ω. In case necessary, please consult your supply authority for system impedance information.
This appliance MSAFD-17HRN1-QC5 can be connected only to a supply with system impedance no more than 0.210Ω. In case necessary, please consult your supply authority for system impedance information.
This appliance MSAFD-22HRN1-QC6 can be connected only to a supply with system impedance no more than 0.129Ω. In case necessary, please consult your supply authority for system impedance information.
45
Remote Manual
AIR CONDITIONER
REMOTE CONTROLLER ILLUSTRATION
Thank you very much for purchasing our air conditioner.
Please read this owner’s manual carefully before using your air conditioner. Make sure to save this manual for future reference.
46
Remote Manual
CONTENTS
Remote controller Specifications
................................................. 48
Operation buttons .......................................................................... 49
Indicators on LCD
.......................................................................... 52
How to use the buttons ................................................................. 53
Auto operation ............................................................................... 53
Cooling/Heating/Fan operation
..................................................... 53
Dehumidifying operation
............................................................... 54
Adjusting air flow direction
........................................................... 54
Timer operation .............................................................................. 55
Handling the remote controller ..................................................... 59
NOTE:
● Buttons design is based on typical model and might be slightly different from the actual one you purchased, the actual shape shall prevail.
● All the functions described are accomplished by the unit. If the unit has no this feature, there is no corresponding operation happened when press the relative button on the remote controller.
● When there are wide differences between “Remote controller Illustration” and “USER’S
MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.
47
Remote Controller Specifications
Model
Rated Voltage
Signal Receiving
Range
Environment
RG57A3/BGEF,RG57A2/BGEF,RG57B/BGE,RG57D/BGE
3.0V (Dry batteries R03/LR03×2)
8m
-5ºC ~ 60ºC
Remote Manual
RG57A2/BGEF
(FRESH button is not available)
RG57A3/BGEF
RG57B/BGE
(FRESH button is not available)
RG57D/BGE
48
Remote Manual
1
2
3
4
5
6
7
49
Operation of buttons
RG57A3/BGEF
8
9
10
11
12
13
14 a ON/OFF Button
This button turns the air conditioner ON and OFF.
b MODE Button
Press this button to modify the air conditioner mode in a sequence of following:
AUTO COOL DRY HEAT FAN
NOTE: Please do not select HEAT mode if the machine you purchased is cooling only type.
Heat mode is not supported by the cooling only appliance.
c FAN Button
Used to select the fan speed in four steps:
AUTO LOW MED HIGH
NOTE: You can not switch the fan speed in
AUTO or DRY mode.
d SLEEP Button
● Active/Disable sleep function. It can maintain the most comfortable temperature and save energy. This function is available on COOL,
HEAT or AUTO mode only.
● For the detail, see “sleep operation” in
“USER’S MANUAL”.
NOTE: While the unit is running under
SLEEP mode, it would be cancelled if MODE,
FAN SPEED or ON/OFF button is pressed.
e FRESH Button (applicable to RG57A3/
BGEF and RG57D/BGE only)
Active/Disable FRESH function. When the
FRESH function is initiated, the Ionizer/
Plasma Dust Collector (depending on models) is energized and will help to remove pollen and impurities from the air.
f TURBO Button
Active/Disable Turbo function. Turbo function enables the unit to reach the preset temperature at cooling or heating operation in the shortest time (if the indoor unit does not support this function, there is no corresponding operation happened when pressing this button.) g SELF CLEAN Button (applicable to Rg57
(A2)A3/BGEF)
Active/Disable Self Clean function
Remote Manual
1
2
3
4
6
Operation of buttons
RG57B/BGE
8
11
12
9
10
14 h UP Button ( )
Push this button to increase the indoor temperature setting in 1ºC increments to
30ºC.
DOWN Button ( )
Push this button to decrease the indoor temperature setting in 1ºC increments to
17ºC.
NOTE: Temperature contol is not available in Fan mode.
i SHORTCUT Button
● Used to restore the current settings or resume previous settings.
● On the first time connecting to the power, if push the SHORTCUT button, the unit will operate on AUTO mode, 26ºC, and fan speed is Auto.
● Push this button when remote controller is on, the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed level and sleep feature (if activated).
● If pushing more than 2 seconds, the system will automatically restore the current operation settings including operating mode, setting temperature, fan speed level and sleep feature (if activated).
j TIMER ON Button
Press this button to initiate the auto-on time sequence. Each press will increase the auto-timed setting in 30 minutes increments.
When the setting time displays 10.0, each press will increase the autotimed setting
60 minutes increments. To cancel the autotimed program, simply adjust the auto-on time to 0.0.
k TIMER OFF Button
Press this button to initiate the auto-off time sequence. Each press will increase the auto -timed setting in 30 minutes increments.
When the setting time displays 10.0, each press will increase the auto-timed setting
60 minutes increments. To cancel the autotimed program, simply adjust the auto-off time to 0.0
50
Remote Manual
1
2
3
4
6
1
2
3
4
6
7
Operation of buttons
RG57A2/BGEF
8
9
10
11
12
14
8
9
10
11
12
13
14 l Swing Button (applicable to RG57 (A2)
A3/BGEF)
Used to stop or start vertical louver movement and set the desired left/right air flow direction.
The vertical louver changes 6 degree in angle for each press. And the temperature display area of indoor unit displays ’ ’ for one second. If keep pushing more than 2 seconds, the vertical louver swing feature is activated. And the display area of indoor unit displays ’ IIII ’, flashes four times, then the temperature setting reverts back. If the vertical louver swing feature is stopped, it displays ’LC’ and remains on for 3 seconds.
Swing Button (applicable to RG57A3
(A2)/BGEF)
Used to stop or start horizontal louver movement or set the desired up/down air flow direction. The louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds, the louver will swing up and down automatically.
SWING Button (applicable to RG57B (D)/
BGE)
Used to stop or start horizontal louver auto swing feature.
DIRECT Button (applicable to RG57B (D)/
BGE)
Used to change the louver movement and set the desired up/down air flow direction.
The louver changes 6º in angle for each press.
m FOLLOW ME Button
(applicable to RG57 (A2)A3/BGEF)
Push this button to initiate the Follow
Me feature, the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again. The air conditioner will cancel the Follow Me feature automatically if it does not receive the signal during any 7 minutes interval.
n LED Button
Disable/Active indoor screen Display. When pushing the button, the indoor screen display is cleared, press it again to light the display.
51
RG57D/BGE
Indicators on LCD
Information are displayed when the remote controller is powered up.
Remote Manual
Mode display
AUTO COOL
HEAT FAN
DRY
Displayed when data transmitted.
Displayed when remote controller is ON.
Battery display (low battery detection)
Not available for this unit
Displayed when TIMER ON time is set.
Displayed when TIMER OFF time is set.
Show set temperature or room temperature, or time under TIMER setting.
Displayed in Sleep Mode operation.
Indicated that the air conditioner is operating in Follow me mode
Not available for this unit
Not available for this unit
Fan speed indication
Low speed
Medium speed
High speed
Auto fan speed
Note:
All indicators shown in the figure are for the purpose of clear presentation. But during the actual operation only the relative functional signs are shown on the display window.
52
Remote Manual
53
3
1
4
1
3
How to use the buttons
2
2
Auto operation
Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing.
1. Press the MODE button to select Auto.
2. Press the UP/DOWN button to set the desired temperature. The temperature can be set within a range of 17ºC ~ 30ºC in 1ºC increments.
3. Press the ON/OFF button to start the air conditioner.
NOTE
1. In the Auto mode, the air conditioner can logically choose the mode of Cooling, Fan, and Heating by sensing the difference between the actual ambient room temperature and the setting temperature on the remote controller.
2. In the Auto mode, you can not switch the fan speed. It has already been automatically controlled.
3. If the Auto mode is not comfortable for you, the desired mode can be selected manually.
Cooling /Heating/Fan operation
Ensure the unit is plugged in and power is available.
1. Press the MODE button to select COOL,
HEAT (cooling & heating models only) or
FAN mode.
2. Press the UP/DOWN buttons to set the desired temperature. The temperature can be set within a range of 17ºC ~ 30ºC in 1ºC increments.
3. Press the FAN button to select the fan speed in four steps-Auto, Low, Med, or High.
4. Press the ON/OFF button to start the air conditioner.
NOTE
In the FAN mode, the setting temperature is not displayed in the remote controller and you are not able to control the room temperature either. In this case, only step 1,
3 and 4 may be performed.
Remote Manual
3
1
How to use the buttons
2
Dehumidifying operation
Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing.
1. Press the MODE button to select DRY mode.
2. Press the UP/DOWN buttons to set the desired temperature. The temperature can be set within a range of 17ºC ~ 30ºC in 1ºC increments.
3. Press the ON/OFF button to start the air conditioner.
NOTE
In the Dehumidifying mode, you can not switch the fan speed. It has already been automatically controlled.
Adjusting air flow direction
Use the SWING & button to adjust the desired airflow direction.
1. Up/Down direction can be adjusted with the
button on the remote controller. Each time when you press the button, the louver moves an angle of 6 degree. If pressing more than 2 seconds ,the louver will swing up and down automatically.
2. Left/Right direction can be adjusted with the
button on the remote controller. Each time when you press the button, the louver moves an angle of 6 degree. If pressing more than 2 seconds ,the louver will swing up and down automatically.
When the louver swing or move to a position which would affect the cooling or heating effect of the air conditioner, it would automatically change the swing/ moving direction.
54
Remote Manual
1
2
Timer operation
Press the TIMER ON button can set the auto-on time of the unit. Press the TIMER OFF button can set the auto-off time of the unit.
To set the Auto-on time.
1. Press the TIMER ON button. The remote controller shows TIMER ON, the last Autoon setting time and the signal “H” will be shown on the LCD display area. Now it is ready to reset the Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired Auto-on time. Each time you press the button, the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours.
3. After setting the TIMER ON ,there will be a one second delay before the remote controller transmits the signal to the air conditioner. Then, after approximately another 2 seconds, the signal “h” will disappear and the set temperature will re-appear on the LCD display window.
To set the Auto-off time.
1. Press the TIMER OFF button. The remote controller shows TIMER OFF, the last Autooff setting time and the signal “H” will be shown on the LCD display area. Now it is ready to reset the Auto-off time to stop the operation.
2. Push the TIMER OFF button again to set desired Auto-off time. Each time you press the button, the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours.
3. After setting the TIMER OFF, there will be a one second delay before the remote controller transmits the signal to the air conditioner. Then, after approximately another 2 seconds, the signal “H” will disappear and the set temperature will re-appear on the LCD display window.
55
Remote Manual
CAUTION
● When you select the timer operation, the remote controller automatically transmits the timer signal to the indoor unit for the specified time. Therefore, keep the remote controller in a location where it can transmit the signal to the indoor unit properly.
● The effective operation time set by the remote controller for the timer function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0,
7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13, 14, 15,16,17, 18, 19, 20, 21, 22, 23 and 24.
Example of timer setting
Start
TIMER ON
(Auto-on Operation)
The TIMER ON feature is useful when you want the unit to turn on automatically before you return home. The air conditioner will automatically start operating at the set time.
Off
Set 6 hours later
Example:
To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last setting of starting operation time and the signal “H” will show on the display area.
2. Press the TIMER ON button to display “6.0H” on the TIMER ON display of the remote controller.
3. Wait for 3 seconds and the digital display area will show the temperature again. The
“TIMER ON” indicator remains on and this function is activated.
56
Remote Manual
On
Set
Stop
10 hours later
Start
Stop
On
Set 2 hours later after setting
10 hours later after setting
TIMER OFF
(Auto-off Operation)
The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed. The air conditioner will stop automatically at the set time.
Example:
To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the last setting of stopping operation time and the signal “H” will show on the display area.
2. Press the TIMER OFF button to display
“10H” on the TIMER OFF display of the remote controller.
3. Wait for 3 seconds and the digital display area will show the temperature again. The
“TIMER OFF” indicator remains on and this function is activated.
COMBINED TIMER
(Setting both ON and OFF timers simultaneously)
TIMER OFF → TIMER ON
(On → Stop → Start operation)
This feature is useful when you want to stop the air conditioner after you go to bed, and start it again in the morning when you wake up or when you return home.
Example:
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to display 2.0H on the TIMER OFF display.
3. Press the TIMER ON button.
4. Press the TIMER ON button again to display
10H on the TIMER ON display.
5. Wait for 3 seconds and the digital display area will show the temperature again. The
“TIMER ON OFF” indicator remains on and this function is activated.
57
Off
Start
Stop
Set 2 hours later after setting
5 hours later after setting
Remote Manual
TIMER ON → TIMER OFF
(Off → Start → Stop operation)
This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house.
Example:
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again to display
2.0H on the TIMER ON display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to display 5.0H on the TIMER OFF display .
5. Wait for 3 seconds and the digital display area will show the temperature again.
The “TIMER ON & TIMER OFF” indicator remains on and this function is activated.
58
Remote Manual
Handling the remote controller
8m
MOD
E
SLEE
P
SWIN
G
DIRE
CT
TEM
P
SHO
ON R
SELF
CLE O
RE
SET
L
ED
ME
TIM
ER
FA
N
RTC
UT
Location of the remote controller.
● Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.
CAUTIONS
● The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit.
● Prevent any liquid from falling into the remote controller. Do not expose the remote controller to direct sunlight or heat.
● If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
● If other electrical appliances react to the remote controller, either move these appliances or consult your local dealer.
● Do not drop the remote controller. Handle with care.
● Do not place heavy objects on the remote controller, or step on it.
Using the remote controller holder
(optional)
● The remote controller can be attached to a wall or pillar by using a remote controller holder (not supplied, purchased separately).
● Before installing the remote controller, check that the air conditioner receives the signals properly.
● Install the remote controller with two screws.
● For installing or removing the remote controller, move it up or down in the holder.
59
Remote Manual
Replacing batteries
The following cases signify exhausted batteries.
Replace old batteries with new ones.
● Receiving beep is not emitted when a signal is transmitted.
● Indicator fades away.
The remote controller is powed by two dry batteries (R03/LR03×2) housed in the back rear part and protected by a cover.
(1) Remove the cover in the rear part of the remote controller.
(2) Remove the old batteries and insert the new batteries,placing the (+) and (-) ends correctly.
(3) Install the cover back on.
NOTE: When the batteries are removed, the remote controller erases all programming. After inserting new batteries, the remote controller must be reprogrammed.
CAUTIONS
● Do not mix old and new batteries or batteries of different types.
● Do not leave the batteries in the remote controller if they are not going to be used for 2 or 3 months.
● Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
60
Remote Manual
AIR CONDITIONER
REMOTE CONTROLLER ILLUSTRATION
61
Thank you very much for purchasing our air conditioner.
Please read this owner’s manual carefully before using your air conditioner. Make sure to save this manual for future reference.
Remote Manual
CONTENTS
Remote controller Specifications
................................................. 63
Operation buttons .......................................................................... 64
Indicators on LCD
.......................................................................... 67
How to use the buttons ................................................................. 68
Auto operation ............................................................................... 68
Cooling/Heating/Fan operation
..................................................... 68
Dehumidifying operation
............................................................... 69
Timer operation .............................................................................. 70
Handling the remote controller ..................................................... 74
62
Remote Manual
Remote Controller Specifications
Model
Rated Voltage
Signal Receiving
Range
Environment
RG57A7/BGEF,RG57B1/BGE
3.0V (Dry batteries R03/LR03×2)
8m
-5ºC ~ 60ºC
63
RG57A7/BGEF RG57B1/BGE
Remote Manual
1
2
3
4
5
6
Operation of buttons
RG57A7/BGEF
7
9
8
10
11
12
13
14 a ON/OFF Button
This button turns the air conditioner ON and
OFF.
b MODE Button
Press this button to modify the air conditioner mode in a sequence of following:
AUTO COOL DRY HEAT FAN
NOTE: Please do not select HEAT mode if the machine you purchased is cooling only type. Heat mode is not supported by the cooling only appliance.
c FAN Button
Used to select the fan speed in four steps:
AUTO LOW MED HIGH
NOTE: You can not switch the fan speed in
AUTO or DRY mode.
d SLEEP Button
● Active/Disable sleep function. It can maintain the most comfortable temperature and save energy. This function is available on COOL,
HEAT or AUTO mode only.
● For the detail, see “sleep operation” in
“USER’S MANUAL”.
NOTE: While the unit is running under
SLEEP mode, it would be cancelled if MODE,
FAN SPEED or ON/OFF button is pressed.
e TURBO Button
Active/Disable Turbo function. Turbo function enables the unit to reach the preset temperature at cooling or heating operation in the shortest time (if the indoor unit does not support this function, there is no corresponding operation happened when pressing this button.) f SELF CLEAN Button
(applicable to RG57A7/BGEF)
Active/Disable Self Clean function
64
Remote Manual
65
1
2
3
4
5
Operation of buttons
RG57B1/BGE
7
8
9
10
11
12
14 g UP Button ( )
Push this button to increase the indoor temperature setting in 1ºC increments to
30ºC.
DOWN Button ( )
Push this button to decrease the indoor temperature setting in 1ºC increments to
17ºC.
NOTE: Temperature contol is not available in Fan mode.
h ECO Button
Used to enter the energy efficient mode.
Under cooling mode, press this button, the remote controller will adjust the temperature automatically to 24ºC, fan speed of Auto to save energy (but only if the set temperature is less than 24ºC). If the set temperature is between 24ºC and 30ºC, press the ECO button, the fan speed will change to Auto, the set temperature will remain unchanged.
NOTE:
● Pressing the TURBO and SLEEP button, modifying the mode or adjusting the set temperature to less than 24ºC will stop ECO operation.
● Under ECO operation, the set temperature should be 24ºC or more. it may result in insufficient cooling. If you feel uncomfortable, just press the ECO button again to stop it.
i TIMER ON Button
Press this button to initiate the auto-on time sequence. Each press will increase the autotimed setting in 30 minutes increments. When the setting time displays 10.0, each press will increase the autotimed setting 60 minutes increments. To cancel the auto-timed program, simply adjust the auto-on time to 0.0.
j TIMER OFF Button
Press this button to initiate the auto-off time sequence. Each press will increase the auto
-timed setting in 30 minutes increments. When the setting time displays 10.0, each press will increase the auto-timed setting 60 minutes increments. To cancel the autotimed program, simply adjust the auto-off time to 0.0
1
2
3
4
5
1
2
3
4
5
6
Operation of buttons
RG57A7/BGEF
7
8
9
10
11
12
14
7
8
9
10
11
12
13
14
Remote Manual k SWING Button
Used to stop or start horizontal louver auto swing feature.
l DIRECT Button
Used to change the louver movement and set the desired up/down air flow direction.
The louver changes 6º in angle for each press.
m FOLLOW ME Button
(applicable to RG57A7/BGEF)
Push this button to initiate the Follow
Me feature, the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again. The air conditioner will cancel the Follow Me feature automatically if it does not receive the signal during any 7 minutes interval.
n LED Button
Disable/Active indoor screen Display. When pushing the button, the indoor screen display is cleared, press it again to light the display.
NOTE:
● Buttons design is based on typical model and might be slightly different from the actual one you purchased, the actual shape shall prevail.
● All the functions described are accomplished by the unit. If the unit has no this feature, there is no corresponding operation happened when press the relative button on the remote controller.
● When there are wide differences between
“Remote controller Illustration” and “USER’S
MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.
RG57B1/BGE
66
Remote Manual
Indicators on LCD
Information are displayed when the remote controller is powered up.
Mode display
AUTO COOL
HEAT FAN
DRY
Displayed when data transmitted.
Displayed when remote controller is ON.
Battery display (low battery detection).
Displayed when ECO feature is activated.
Displayed when TIMER ON time is set.
Displayed when TIMER OFF time is set.
Shows set temperature or room temperature, or time under TIMER setting.
Displayed in Sleep Mode operation.
Indicated that the air conditioner is operating in Follow me mode.
Not available for this unit.
Not available for this unit.
Fan speed indication
Low speed
Medium speed
High speed
Auto fan speed
Note:
All indicators shown in the figure are for the purpose of clear presentation. But during the actual operation only the relative functional signs are shown on the display window.
67
Remote Manual
3
1
4
1
3
How to use the buttons
2
2
Auto operation
Ensure the unit is plugged in and power is available.
1. Press the MODE button to select Auto.
2. Press the UP/DOWN button to set the desired temperature. The temperature can be set within a range of 17ºC ~ 30ºC in 1ºC increments.
3. Press the ON/OFF button to start the air conditioner.
NOTE
1. In the Auto mode, the air conditioner can logically choose the mode of Cooling, Fan, and Heating by sensing the difference between the actual ambient room temperature and the setting temperature on the remote controller.
2. In the Auto mode, you can not switch the fan speed. It has already been automatically controlled.
3. If the Auto mode is not comfortable for you, the desired mode can be selected manually.
Cooling /Heating/Fan operation
Ensure the unit is plugged in and power is available.
1. Press the MODE button to select COOL,
HEAT (cooling & heating models only) or
FAN mode.
2. Press the UP/DOWN buttons to set the desired temperature. The temperature can be set within a range of 17ºC ~ 30ºC in 1ºC increments.
3. Press the FAN button to select the fan speed in four steps- Auto, Low, Med,or High.
4. Press the ON/OFF button to start the air conditioner.
NOTE
In the FAN mode, the setting temperature is not displayed in the remote controller and you are not able to control the room temperature either. In this case, only step 1,
3 and 4 may be performed.
68
Remote Manual
3
1
How to use the buttons
2
Dehumidifying operation
Ensure the unit is plugged in and power is available.
1. Press the MODE button to select DRY mode.
2. Press the UP/DOWN buttons to set the desired temperature. The temperature can be set within a range of 17ºC ~ 30ºC in 1ºC increments.
3. Press the ON/OFF button to start the air conditioner.
NOTE
In the Dehumidifying mode, you can not switch the fan speed. It has already been automatically controlled.
69
1
2
Remote Manual
Timer operation
Press the TIMER ON button can set the auto-on time of the unit. Press the TIMER OFF button can set the auto-off time of the unit.
To set the Auto-on time.
1. Press the TIMER ON button. The remote controller shows TIMER ON, the last Autoon setting time and the signal “H” will be shown on the LCD display area. Now it is ready to reset the Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired Auto-on time. Each time you press the button, the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours.
3. After setting the TIMER ON ,there will be a one second delay before the remote controller transmits the signal to the air conditioner. Then, after approximately another 2 seconds, the signal “h” will disappear and the set temperature will re-appear on the LCD display window.
To set the Auto-off time.
1. Press the TIMER OFF button. The remote controller shows TIMER OFF, the last Autooff setting time and the signal “H” will be shown on the LCD display area. Now it is ready to reset the Auto-off time to stop the operation.
2. Push the TIMER OFF button again to set desired Auto-off time. Each time you press the button, the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours.
3. After setting the TIMER OFF ,there will be a one second delay before the remote controller transmits the signal to the air conditioner. Then, after approximately another 2 seconds, the signal “H” will disappear and the set temperature will re-appear on the LCD display window.
70
Remote Manual
CAUTION
● The effective operation time set by the remote controller for the timer function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0,
7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13, 14, 15,16,17, 18, 19, 20, 21, 22, 23 and 24.
Example of timer setting
Set
Off
Start
6 hours later
TIMER ON
(Auto-on Operation)
The TIMER ON feature is useful when you want the unit to turn on automatically before you return home. The air conditioner will automatically start operating at the set time.
Example:
To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last setting of starting operation time and the signal “H” will show on the display area.
2. Press the TIMER ON button to display “6.0H” on the TIMER ON display of the remote controller.
3. Wait for 3 seconds and the digital display area will show the temperature again. The
“TIMER ON” indicator remains on and this function is activated.
71
On
Set
Stop
10 hours later
Start
Stop
On
Set 2 hours later after setting
10 hours later after setting
Remote Manual
TIMER OFF
(Auto-off Operation)
The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed. The air conditioner will stop automatically at the set time.
Example:
To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the last setting of stopping operation time and the signal “H” will show on the display area.
2. Press the TIMER OFF button to display
“10H” on the TIMER OFF display of the remote controller.
3. Wait for 3 seconds and the digital display area will show the temperature again. The
“TIMER OFF” indicator remains on and this function is activated.
COMBINED TIMER
(Setting both ON and OFF timers simultaneously)
TIMER OFF → TIMER ON
(On → Stop → Start operation)
This feature is useful when you want to stop the air conditioner after you go to bed, and start it again in the morning when you wake up or when you return home.
Example:
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to display 2.0H on the TIMER OFF display.
3. Press the TIMER ON button.
4. Press the TIMER ON button again to display
10H on the TIMER ON display .
5. Wait for 3 seconds and the digital display area will show the temperature again. The
“TIMER ON OFF” indicator remains on and this function is activated.
72
Remote Manual
Off
Start
Stop
Set 2 hours later after setting
5 hours later after setting
TIMER ON → TIMER OFF
(Off → Start → Stop operation)
This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house.
Example:
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again to display
2.0H on the TIMER ON display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to display 5.0H on the TIMER OFF display .
5. Wait for 3 seconds and the digital display area will show the temperature again.
The “TIMER ON & TIMER OFF” indicator remains on and this function is activated.
The device could comply with the local national regulations.
● In Canada, it should comply with CAN ICES-3 (B)/NMB-3 (B).
● In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
● Consult the dealer or an experienced radio/TV technician for help.
73
Remote Manual
Handling the remote controller
8m
MOD
E
SLEE
P
SWIN
G
DIRE
CT
TEM
P
SHO
ON R
SELF
CLE O
RE
SET
L
ED
ME
TIM
ER
FA
N
RTC
UT
Location of the remote controller.
● Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.
CAUTIONS
● The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit.
● Prevent any liquid from falling into the remote controller. Do not expose the remote controller to direct sunlight or heat.
● If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
● If other electrical appliances react to the remote controller, either move these appliances or consult your local dealer.
● Do not drop the remote controller. Handle with care.
● Do not place heavy objects on the remote controller, or step on it.
Using the remote controller holder
(optional)
● The remote controller can be attached to a wall or pillar by using a remote controller holder (not supplied, purchased separately).
● Before installing the remote controller, check that the air conditioner receives the signals properly.
● Install the remote controller with two screws.
● For installing or removing the remote controller, move it up or down in the holder.
74
Remote Manual
Replacing batteries
The following cases signify exhausted batteries.
Replace old batteries with new ones.
● Receiving beep is not emitted when a signal is transmitted.
● Indicator fades away.
The remote controller is powered by two dry batteries (R03/LR03×2) housed in the back rear part and protected by a cover.
(1) Remove the cover in the rear part of the remote controller.
(2) Remove the old batteries and insert the new batteries, placing the (+) and (-) ends correctly.
(3) Install the cover back on.
NOTE: When the batteries are removed, the remote controller erases all programming. After inserting new batteries, the remote controller must be reprogrammed.
CAUTIONS
● Do not mix old and new batteries or batteries of different types.
● Do not leave the batteries in the remote controller if they are not going to be used for
2 or 3 months.
● Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
75
Questions or comments?
COUNTRY
IRAN
SAUDI ARABIA
CALL
021-8255
8002474357
U.A.E
QATAR
800-SAMSUNG
(800 - 726 7864)
800-CALL (800-2255)
BAHRAIN 8000-GSAM (8000-4726)
OMAN 800-SAM CS (800-72627)
JORDAN
SYRIA
LEBANON
EGYPT
MOROCCO
KUWAIT
0800-22273
06 5777444
962 5777444
1299
08000-7267864
16580
080 100 22 55
183-CALL (183-2255)
NIGERIA
ALGERIA
0800-726-7864
3004
PAKISTAN 0800-Samsung (72678)
TUNISIA
SOUTH AFRI
CA
GHANA
ZAMBIA
ISRAEL
-
80 100 012
0860 SAMSUNG (726
7864)
0800-100-077
3434
*6963
OR VISIT US ONLINE AT www.samsung.com/iran/support www.samsung.com/sa/home www.samsung.com/sa_en www.samsung.com/ae/support (English) www.samsung.com/ae_ar/support (Arabic) www.samsung.com/ae/support (English) www.samsung.com/ae_ar/support (Arabic) www.samsung.com/ae/support (English) www.samsung.com/ae_ar/support (Arabic) www.samsung.com/ae/support (English) www.samsung.com/ae_ar/support (Arabic) www.samsung.com/levant www.samsung.com/levant www.samsung.com/levant/support www.samsung.com/eg/support www.samsung.com/n_africa/support www.samsung.com/ae/support (English) www.samsung.com/ae_ar/support (Arabic) www.samsung.com/africa_en/support www.samsung.com/n_africa/support www.samsung.com/pk/support www.samsung.com/n_africa/support www.samsung.com/support www.samsung.com/africa_en/support www.samsung.com/support www.samsung.com/il/support/

Download
Advertisement
Key features
- Auto-Restart Function
- Anti-Mildew Feature
- Optional Wireless Control
- Sleep Operation for Energy Saving
- Louver Angle Memory
- Refrigerant Leakage Detection