General Pump 24 in. 4000 psi 8 GPM Pressure Washer Flat Surface Cleaner Product information
General Pump DCFSCP24GZ is a professional flat surface cleaner designed for heavy-duty cleaning tasks. With a full 24" cleaning path and operating pressures ranging from 1,000 to 4,000 PSI, it delivers exceptional cleaning performance on large flat surfaces like driveways, patios, and sidewalks. Its durable construction featuring anodized aluminum components and a rugged ABS cover ensures longevity.
Advertisement
Advertisement
AVAILABLE REPAIR KITS
Rotary Head Kit - Major:
P/N 2100372
Includes items 2, 3, 4, 5, 6, 7, 8, 9,
10, 11, 12, 13, 14, 15 and 17
Rotary Head Kit - Minor:
P/N 2100203
Includes items 9, 10, 15 and 17
Complete Rotary Head Kit:
P/N 2103220
Includes all items
Replacement Nozzles
For Arm 2103288:
P/N 925020M
(3 Required)
Photo of Rotary Head - Major as assembled.
ITEM
NO.
13
14
15
16
17
9
10
11
12
7
8
5
6
3
4
1
2
PART
NO.
DESCRIPTION
2500010 HOUSING
2520030 RETAINER, BEARING
2520028 RETAINER, BEARING
2520027 SPACER, BEARING
2640004 BEARING
2701012 O-RING
2701011 O-RING
2701010 O-RING
2720007 SPRING
2530008 PIN
2530007 STEM, SMALL
2520029 SNAP RING
2710000 BACK UP RING
2520113 STEM
2200092 SCREW, M5 X 16
2200050 WASHER
2500012 RETAINER, BEARING
Ref 300988 Rev. B
07-17
QTY.
3
3
1
1
1
1
3
1
2
1
1
2
1
1
2
1
1
PROFESSIONAL FLAT SURFACE CLEANER
FROM GENERAL PUMP
• COMPENSATING GUN FEATURE
• FULL 24” CLEANING PATH
• HEAVY-DUTY ANODIZED
ALUMINUM COMPONENTS
• RUGGED ABS COVER
• SWIVEL HAS GREASE ZERK
FOR BEARING LUBRICATION
DCFSCP24GZ
OPERATOR’S MANUAL
General Pump is a member of the
Interpump Group
Ref 300988 Rev. B
07-17
WARNING: Read Before Operating Machine
Always wear protective eyewear
Keep clear of rotating nozzles
Never lock trigger gun open with any device
Drain water in cold weather to avoid freezing
Tampering with any part of this machine will void all warranties
8
Operating Instructions
1. Bolt the two halves of the handle together with the two M6 x 60mm long bolts, nylok nuts and
four washers.
2. Connect the handle to the brackets on the deck with the two 55mm long pins and rings.
3. Using thread sealant on hose’s male threads, connect the hose to the swivel on the deck.
4. Again, using thread sealant, attach the in-line filter to the inlet of the gun.
5. Connect inlet flter, D40014, to FSC gun inlet.
6. Connect to Pressure Washer.
7. Turn water on and open valve. Open trigger gun for flow of water through nozzles. Nozzles
must have flowing spray. If not, remove tips and clean; reassemble, making sure that groove of
nozzle is parallel to spray bar. Use thread sealant when installing nozzles.
8. Start Pressure Washer. The Hammerhead is ready for operation.
9. Walk slowly behind the Hammerhead cleaning as you go. If striping occurs, slow down your
pace.
10. Periodically check weep hole on bottom of swivel. Water will seep slowly; if water shoots out,
stop and replace seals. Swivel assembly can be rebuilt.
11. For maximum effectiveness keep spray tips clean. If the machine vibrates, stop and clean spray tips.
12.Grease the swivel with one or two grease gun pumps every 200 hours (or once about every 30
days of use). Use No. 2 general purpose waerproof lithium grease. For hot water applications,
use a quality high temperaure grease.
NOTE: NOTE: After 50 hours of use, remove the inlet filter, take apart and clean filter screen.
DO NOT ALLOW MACHINE TO REMAIN STATIONARY
ON SOFT SURFACES SUCH AS WOOD.
Caution: Striking any raised obstacle during operation will damage machine. If contact does
occur and results in vibration when operating machine, STOP and replace spray bar. Continued
operation could result in serious injury or damage to machine.
STORAGE NOTE
When storing the FSC for a few weeks or months, it is best to drain as much water as possible.
Disconnect the FSC from the pump and stand the handle up. Clamp the gun trigger open and let the water run out. Shop air can also be used at the gun inlet to force out the water.
IMPORTANT: TROUBLEHOOTING
If the flat surface cleaner rotating arm is not spinning, tilt the flat surface cleaner up so you can see the underside of the deck. If a nozzle is not spraying it is plugged and needs to be cleaned. The best way is to do this is to remove the nozzle (9/16” wrench) and tap it on a hard surface (be careful not to damage the threads). Sometimes it’s necessary to unplug the nozzle by running a thin wire through the tip.
Seal the threads before replacing the nozzle. Teflon tape can often plug a nozzle so be sure tape does not get into the nozzle flow path. A light duty liquid or paste thread sealant is the best way to seal the threads. SEE PHOTO BELOW.
General Pump
1174 Northland Drive • Mendota Heights, MN 55120
Phone: 651.686.2199 • Fax: 800.535.1745
www.generalpump.com • [email protected]
Ref 300988 Rev.B
07-17
21
18
4
5
14
24
23
10
9
19
16
15
22 20
7
17
6
2
3
25
13
28
12
26
1
8
11 Operating Pressures:
1,000 to 4,000 PSI
Max Flow: 8.0 GPM
Dimensions: 70” x 21” x 21”
Weight: 21 lbs.
ITEM
NO.
PART
NO.
DESCRIPTION QTY.
7
8
5
6
3
4
1
2
2630010 PLATE, RETAINING
2540023 COLLAR, SPLIT
2540020 BLOCK, HANDLE
2660047 GRIP, HANDLE
2660046 PLUG, HANDLE
2200055 SHCS, M8 X 30
2200054 SHCS
2200053 NUT, M8X1.25
9 D10009 PLUG, 3/8 X 3/8-M
10 D10004 QC, 3/8 X 3/8 NPT-M
11 2200047 BOLT, M6
12 2203406 WASHER, M6
13 2202010 PIN, 55MM, W/RING, SS
14 2200058 HHCS, M6 X 60
8
8
1
1
2
2
1
1
1
1
2
1
1
1
27
ITEM
NO.
PART
NO.
DESCRIPTION QTY.
15
16
2200026 NUT, NYLOK, M6
2200018 WASHER, M6
17 2203507 WASHER
18 DCG4000FSC GUN, FSC
23
24
25
26
27
28
19
20
21
22
2702000 HOSE, FSC
2540021 HANDLE, LOWER
2540037 HANDLE, FSC, UPPER
2103220 SWIVEL
D40014 FILTER, IN-LINE, BRASS
2103016 NOZZLE
2660317 DECK, FSC, 24” 1
2103288 ARM, ROTARY, ASSY, 24” 1
1
2
2103289 BRUSH ASSY, 24”
2103228 CASTER KIT,SS
1
1
1
1
1
1
1
1
2
4
Ref 300988 Rev. B