TECHNICAL DATA
ZNR-35
LOCK-DOWN
PRIMER & CONDITIONER
.DESCRIPTION AND USES
.
.PRODUCT APPLICATION (cont.)
®
SURFACE PREPARATION (cont.)
Zinsser Lock-Down is a high performance water-based
primer and conditioner that penetrates and seals vertical
concrete, masonry, and stucco. Lock-Down provides
excellent adhesion to lock down chalky and spalling
surfaces and bind paint. The advanced formula has
excellent efflorescence and alkali resistance for long
lasting protection. Ideal for sealing exterior and interior
vertical surfaces. Lock-down can be applied in
temperatures down to 35°F and tolerates high PH levels
(up to 13) for application to new concrete and masonry in
as soon as seven days. The white guide-coat aids in the
visibility of application. This coatings dries to a semitranslucent white color.
WARNING! If you scrape, sand or remove old paint, you
may release lead dust. LEAD IS TOXIC. EXPOSURE TO
LEAD DUST CAN CAUSE SERIOUS ILLNESS, SUCH AS
BRAIN DAMAGE, ESPECIALLY IN CHILDREN.
PREGNANT WOMEN SHOULD ALSO AVOID
EXPOSURE. Wear a NIOSH-Approved respirator to
control lead exposure. Clean up carefully with a HEPA
vacuum and a wet mop. Before you start, find out how to
protect yourself and your family by contacting the National
Lead Information Hotline at 1-800-424-LEAD or log on to
www.epa.gov/lead.
APPLICATION
Zinsser Lock-Down is suitable for use on concrete
(including new tilt-up structures), stucco, masonry, fiber
cement siding, concrete block, EIFS, brick, interior plaster,
drywall, joint compounds, and torn drywall facing paper.
. FEATURES






Mix thoroughly to ensure any settled pigment is redispersed. Apply when air and surface temperature is
between 35°F (2ºC) and 100°F (38ºC). For brush
application, use a high quality synthetic bristle brush. For
roller application use a ⅜” to ¾” synthetic nap roller. For
spray application, follow manufacturer’s instructions for
spray equipment. For Airless spray, use 0.015-0.019” tip
at 1500-2100 psi.
.
Excellent adhesion
Seals chalky surfaces
Low temperature application down to 35ºF
Excellent efflorescence and alkali resistance
Binds paint to new or previously painted surfaces
Apply to new concrete prior to the 30 day cure
PRODUCTS
SKU
322989
322990
TINTING
Lock-Down can be tinted with up to 2 ounces of universal
tint per gallon.
.
COVERAGE
Container Size
1-Gallon Guidecoat White
5-Gallon Guidecoat White
.PRODUCT APPLICATION
.
Lock-Down will cover approximately 200-300 square feet
per gallon. Coverage will vary depending on application
method and surface porosity.
.
DRY TIME
SURFACE PREPARATION
Dry time is based on 70°F and 50% relative humidity.
Lock-Down will dry to touch in approximately 30 minutes
and can be topcoated in 1 hour. Lower temperatures or
higher humidity can prolong dry and cure time.
Surfaces should be clean, dry, sound and free of any
contamination, mildew, or unsound coatings that may
interfere with adhesion. Repair cracks and surface holes
with appropriate sealant. Remove excessive chalk or any
loose paint. If needed, wash surface with a low suds
cleaning solution like ammonia or a TSP substitute. Rinse
thoroughly and allow to dry. Allow new concrete and
masonry to cure for at least 7 days before applying.
CLEAN-UP
Wash promptly with soap and water. Follow equipment
manufacturer instructions for cleaning spray equipment.
LIMITATIONS
Not recommended for application to floors or decks or to
surfaces subject to immersion or prolonged contact with
water. For full surface priming under wallcovering, use
®
Zinsser Gardz Problem Surface Sealer. For maximum
hide, use Zinsser Bulls Eye 1-2-3 Primer & Sealer.
STAIN
S
1
Form: GDH-1368
Rev.: 061217
TECHNICAL DATA
LOCK-DOWN PRIMER & CONDITIONER
.PHYSICAL PROPERTIES
.
Physical Properties
LOCK-DOWN PRIMER & CONDITIONER
Resin Type
Acrylic
Pigment Type
Titanium Dioxide, Calcium Carbonate
Solvents
Weight
Solids
Water, Ethylene Glycol
Per Gallon
8.8 lbs.
Per Liter
1.06 kg
By Weight
18.1%
By Volume
13.3%
Volatile Organic Compounds
<50 g/l
Recommended Dry Film
Thickness (DFT) per Coat
0.5-1.0 mils
(12.5-25µ)
Wet Film to Achieve DFT (Unthinned
material)
4.0-7.5 mils
(100-187.5µ)
Practical Coverage at Recommended
DFT (assume 15% material loss)
Approximately 200-300 sq.ft./gal. (4.9-7.4 m /l)
depending on application method and surface porosity
Touch
Dry Times at 70-80°F
(21-27ºC) and 50%
Relative Humidity
2
30 minutes
Topcoat
1 hour
Fully Dry
24 hours
Shelf Life
2 years
Flash Point
>200ºF (93ºC)
Safety Information
For additional information, see SDS
The technical data and suggestions for use contained herein are correct to the best of our knowledge, and offered in good faith. The
statements of this literature do not constitute a warranty, express, or implied, as to the performance of these products. As conditions and use
of our materials are beyond our control, we can guarantee these products only to conform to our standards of quality, and our liability, if any,
will be limited to replacement of defective materials. All technical information is subject to change without notice.
Rust-Oleum Corporation
11 Hawthorn Parkway
Vernon Hills, Illinois 60061
An RPM Company
Phone: 877•385•8155
www.rustoleum.com
Form: GDH-1368
Rev.: 061217
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement