RINKMO Portable Mini Dehumidifiers for Small Space Up to 1900 Cubic Feet(215 sq ft), Quiet Compact Home Electric Dehumidifier for Kitchen, Bedroom, Basement, Caravan, Office, Garage, RV Dehumidifier User Manual

RINKMO Portable Mini Dehumidifiers for Small Space Up to 1900 Cubic Feet(215 sq ft), Quiet Compact Home Electric Dehumidifier for Kitchen, Bedroom, Basement, Caravan, Office, Garage, RV Dehumidifier User Manual

The RINKMO Portable Mini Dehumidifiers have a 1.4L water tank capacity and a maximum capacity of 2.4L. It has a dehumidification capacity of 420mL/d at 86°F/80%RH and 600mL/d at 95°F/90%RH. It comes with a timing function that allows you to set it to run for a specific number of hours (0-24h) and a humidity control function that lets you set the desired humidity level (30-80%). The dehumidifier also has a full water protection feature that automatically stops the dehumidification process when the tank is full.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
RINKMO Portable Mini Dehumidifiers for Small Space Up to 1900 Cubic Feet(215 sq ft), Quiet Compact Home Electric Dehumidifier for Kitchen, Bedroom, Basement, Caravan, Office, Garage, RV Dehumidifier User Manual | Manualzz
User Manual
DS01A Semi-Conductor Dehumidifier
NN
— |
Before installation and application, please read this manual carefully!
Please keep this manual for future reference!
Technical Specifications
Product name
Semi-Conductor Dehumidifier
model number DSO1A-01
Rated voltage and frequency 110-120V-60HZ
Dehumidification capacity (86°F/80%RH) 420mL/d
Dehumidification capacity (95°F/90%RH) 600mL/d
Rated power 68W
Protection against electric shock type I
Protection level IP20
Water Tank Capacity 1.4L
Water Tank Max Capacity 2.4L
Machine size 190 x 190 x 340 mm
Net weight 2.1kg
Will not advice once specification and design changed.
P12
Preface
Thanks for your trust and support! For
achieving better installation and methods of
this equipment and maximum the function of
this unit, please read this manual carefully
before installation and application.
P.1
Catalog
Thank you for using this product, in order to correct to operation
your product, please read the instructions carefully before use,
be sure to read "Notice" (Will not advice once this specification changed)
Preface oo coo coa coo ceo coa cea coo oa cea coa ea tea coa cea ea ses ses ses ses ses sas ses ses ses ses ses sas
Notice
Product structure ------========e eses vue stn sen vot vos vou vou sue sue sen sae sue vou veu sue 00
Cleaning and maintenance ------------ =r ener ное оне анионы e a ns
Usual Malfunctions and Treatments «cee wees er cvs ere vue eu 000
Safety Notice ------.--.--.- 6.0 eee ee ne nene nene ne nee nene reee aoe sae ses sae ens
P.2
10
11
12
Safety Notice
Do not place unit on uneven Do not insert any sharp objects Do not operate unit near radiators,
surface. into air inlet/airoutlet. kettles or any object that releases
steam.
Do not operate unit near windows Do not obstruct air inlet and outlet. Unplug power when the unitis not
or doors opening to the outdoor. in use for an extended period.
Do not spray any liquid onto unit. Do not put heavy objects on top Wash the air filter once every 2
of unit. weeks with cold water. (Do not
use water >40 or benzene)
When draining water continuously, Do not place filter directly under Empty water tank before moving unit.
make sure drain hose is not tangled.
P11
Usual Malfunctions And Treatments
If there are problems in using the machine to operate, please check in accordance with
the following table.
Failure phenomena
The machine does not
dehumidify
Cause analysis
Whether power line
connected properly?
Processing method
The power cord plug and
socket connectors good.
Notice
Display display "E7"?
(Tank full of water or put
in wrong position)
pull out the water and putin
correct position of the machine.
Room temperature is
between 41°F (5 °C)
to 104°F (40°C) ?
Because this product does not
apply to hot or cold Environment,
dehumidification intermittent work.
Dehumidifying
efficiency poor
Poor air flow
Around the machine should
leave at least 20cm space.
Low humidity or Ambient
temperature is too high.
Replace the use environment.
Running noise bigger
whether the machine
is tilted?
The move to put the machine
to the horizontal position.
Air inlet or outlet blocked?
Clean up dirty at the air inlet
and outlet place.
Note: If the problem persists, please turn off and unplug the power plug, and returned
to our company service.
P10
1.When cleaning or storing the unit, please pull the plug.
2.Do not place the unit near water or immersed in water.
3.Do not place the unit near heating devices or flammable dangerous place.
4.Do not put fingers or stick objects into the air inlet or the outlet.
5.Do not sit on this machine.
6.Follow the requirements to drain out the water tank water.
7.The body should be level, to avoid placing the unit on uneven or sloping ground.
8.Never spray the unitwith water.
9.Do not spray insecticide or flammable liquids on the machine.
10.Do not place heavy objects on the machine or let children, animals ride.
11.The machine can not be operation within a narrow operating space.
12.The power cord is damaged, shall be have approved or qualified technician to
replace it.
13.The machine power supply wiring must be in accordance with national wiring
rules, the power wire securely connected to the external ground.
14.Fixed wiring connecting the machine must be equipped with an all-pole
disconnect device with a contact separation of at least 3mm.
15.When the dehumidifier operation to ensure minimum spacing around it as
shown below:
201
РЗ
Product structure Cleaning and maintenance
Host computer A Attention
To avoid electrical shock, before cleaning and maintenance of the unit must be switched
DSO1A-01 off, and unplug the power cord.
A.Machine cleaning
1. Using a soft slightly damp cloth to wipe the surface of the body, do not use water to clean.
2. Application of serious dirt designated neutral kitchen cleaner to dampen the cloth, wipe
dry after defend.
Air outlet
B.Cleaning water tank
1. Use a soft cloth to clean the water tank inside.
2. Do not cannibalized float assembly, and the elimination of residual water in the
Air inlet float clear, whether the measure will not work float float.
Operation panel
| я Trim
C.Dehumidifier store
Long time will note use the dehumidifiers and want to store it, notice the following steps:
À 1. Empty the water inside the tank.
Water tank 2. Rolled the power cord.
3. Place in the cool dry environment.
P4 P9
Instructions
Remark:
Before starting the machine make sure the outlet is turned on, otherwise the unit will
overheating.
Do not unplug the power cord directly to make the machine power off.
9. Tank drain
When the water tank is full, the display HE will show "E7", dehumidifying stops automatically,
water in the tank to be emptied on this moment.
Empty the water tank
Hold the tank on both sides Reverse water tank emptied. Replace the water tank,
of the handle position, pull the water full indicator
out the water tank. disappears.
Remark:
- Do notremove the float from water tank, otherwise it will not sensing the water level,
and once the water is full does not stop dehumidification, final water will from the
tank overflow.
- If the tank is dirty, use cold or warm water to wash, do not use detergent, just velvet,
chemical processing dust cloth, gasoline, benzene, thinner or other solvents,
otherwise it could cause damage to the tank then lead to leaking
- If the tank is not placed well, the water ull sensor will be on and activated,
dehumidifier will not operate.
P8
Instructions
1, Control Panel
Timing Key
© ©; ©
1
Timing Humidity | Power Supply
1
Power Button
Display
Ou
Humidity Key
Key Description
Timing key
It sets the timing,setting range 0 ~ 24h.
Once Time is set to 00, the timer function ]
is invalid
с
©
PS
Power button
The switch for machine control.
Humidity key
It is used to set the humidity setpoint ,setting
range of 30 to 80%.Set at 30% humidity, the
dehumidifying operation.
Instructions
2,
Set The Humidity
In power on status, press [humidity] key once time, then to enter the set state of humidity,
humidity symbol @ flashes, BHblinks humidity setting value, press [humidity] key once again,
the humidity setting value increase of 10%, setting range 30% ~ 80% RH, the can be cycle set,
continuously forafew seconds no key operation,will automatically exitthe humidity setting state.
If the humidity is set to 30, the machine continuously dehumidifying running
Timing Setting
In the power on / off status, press [Timing] key once time, then enter the timer setting mode,
Timer symbol ® flashes, BH flashing display set time, then press [Timing] key once again,
the regular time increments 1h, setting range 1 ~ 24h, can cycle setting, continuous
seconds no key operation, will automatically exit timer setting mode.
If the timing is 00, the timing function is not valid.
Timing Inquiry
When the timer is valid, press [Timing] key once, the symbol timing O
blinking, HH display the remaining time.
Continuous seconds no key operation will automatically exit the humidity
setting state.
If the revised timing inquiry into the state of timing, no re-timing.
State Memory Function
Set the start and stop switch machine status and humidity set value,
automatic power-off memory. Again after power off, Machine according
to before the power failure state continue to run (the timer ,switch
function failure).
P.6
Instructions
6.
7.
Full Water Protection
Once the machine tank full of water phenomenon occurs, the dehumidifier
stops, fan continue to operate.
Action Description
Power on: fan delay start, then a few seconds later, refrigeration slice open.
Power Off: refrigeration films stop immediately , fan delay stop.
Special notice: fans and cooling sheet start and stop shall meet the requirements set by
the user.
Status Description
Machine is turned on, the humidity indicator ©) light, otherwise off.
Dehumidifying operation state, the humidity indicator ® light; the set humidity or temperature
protection status, humidity indicator @) flashes, otherwise off.
Timing function is active, the timing indicator @ light; the timing set state, the timer lamp ®
blinks, otherwise off.
The machine running, the display HH shows humidity, downtime error code.
Number Fault code Fault Name
1 ET Humidity sensor fault
2 E2 Cold junction temperature sensor fault
3 E4 Ambient temperature sensor failure
4 E7 Full of water alarm
Notice:
1) E1 and E4 fault, dehumidification continuous operation, fan operational as usually.
2) E2 failure, intermittent dehumidification,fan continue to operate.
3) E7 fault the chip cooling stop, fan continue to operate.
P.7

advertisement

Related manuals

Download PDF

advertisement