Varytec Giga Bar 240 LED RGB User Manual
Varytec Giga Bar 240 LED RGB is an LED bar with a beam angle of 30°. It is perfect for stages, clubs and other applications where a powerful and versatile light source is needed. The bar has 240 RGB LEDs and can be controlled via DMX or stand-alone. With its various functions and effects, the Varytec Giga Bar 240 LED RGB is a perfect choice for professional lighting applications.
Advertisement
Advertisement
Giga Bar LED 240 RGB 30°
LED bar
Musikhaus Thomann
Thomann GmbH
Hans-Thomann-Straße 1
96138 Burgebrach
Germany
Telephone: +49 (0) 9546 9223-0
E-mail: [email protected]
Internet: www.thomann.de
05.08.2019, ID: 452370
Table of contents
Table of contents
1 General information................................................................................................................................. 6
1.1 Further information........................................................................................................................... 7
1.2 Notational conventions.................................................................................................................... 8
1.3 Symbols and signal words............................................................................................................... 8
2 Safety instructions.................................................................................................................................. 11
3 Features....................................................................................................................................................... 17
4 Installation.................................................................................................................................................. 19
5 Starting up.................................................................................................................................................. 23
6 Connections and operating elements........................................................................................... 26
7 Operating.................................................................................................................................................... 33
7.1 Starting the device........................................................................................................................... 33
7.2 Main menu.......................................................................................................................................... 33
7.3 Menu overview................................................................................................................................. 42
7.4 Functions in 2-channel DMX mode........................................................................................... 45
7.5 Functions in 3-channel DMX mode........................................................................................... 47
Giga Bar LED 240 RGB 30°
LED bar
3
Table of contents
7.6 Functions in 5-channel DMX mode........................................................................................... 48
7.7 Functions in 24-channel DMX mode........................................................................................ 49
8 Technical specifications....................................................................................................................... 52
9 Plug and connection assignments.................................................................................................. 55
10 Troubleshooting...................................................................................................................................... 56
11 Cleaning....................................................................................................................................................... 58
12 Protecting the environment.............................................................................................................. 59
4 Giga Bar LED 240 RGB 30°
LED bar
Giga Bar LED 240 RGB 30°
LED bar
5
General information
1 General information
This user manual contains important information on the safe operation of the device. Read and follow all safety notes and all instructions. Save this manual for future reference. Make sure that it is available to all persons using this device. If you sell the device to another user, be sure that they also receive this manual.
Our products and user manuals are subject to a process of continuous development. We there‐ fore reserve the right to make changes without notice. Please refer to the latest version of the user manual which is ready for download under www.thomann.de
.
6 Giga Bar LED 240 RGB 30°
LED bar
General information
1.1 Further information
On our website ( www.thomann.de) you will find lots of further information and details on the following points:
Download
Keyword search
Service
This manual is also available as PDF file for you to download.
Use the search function in the electronic version to find the topics of interest for you quickly.
Online guides
Our online guides provide detailed information on technical basics and terms.
Personal consultation For personal consultation please contact our technical hotline.
If you have any problems with the device the customer service will gladly assist you.
Giga Bar LED 240 RGB 30°
LED bar
7
General information
1.2 Notational conventions
This manual uses the following notational conventions:
Letterings The letterings for connectors and controls are marked by square brackets and italics.
Examples: [VOLUME] control, [Mono] button.
Displays Texts and values displayed on the device are marked by quotation marks and italics.
Examples: ‘24ch’ , ‘OFF’ .
1.3 Symbols and signal words
In this section you will find an overview of the meaning of symbols and signal words that are used in this manual.
8 Giga Bar LED 240 RGB 30°
LED bar
Signal word
DANGER!
WARNING!
NOTICE!
Warning signs
General information
Meaning
This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided.
This combination of symbol and signal word indicates a pos‐ sible dangerous situation that can result in death or serious injury if it is not avoided.
This combination of symbol and signal word indicates a pos‐ sible dangerous situation that can result in material and environmental damage if it is not avoided.
Type of danger
Warning – high-voltage.
Warning – dangerous optical radiation.
Giga Bar LED 240 RGB 30°
LED bar
9
General information
Warning signs Type of danger
Warning – suspended load.
Warning – danger zone.
10 Giga Bar LED 240 RGB 30°
LED bar
Safety instructions
2 Safety instructions
Intended use This device is intended for use as an electronic lighting effect by means of LED technology. The device is designed for professional use and is not suitable for use in households. Use the device only as described in this user manual. Any other use or use under other operating con‐ ditions is considered to be improper and may result in personal injury or property damage. No liability will be assumed for damages resulting from improper use.
This device may be used only by persons with sufficient physical, sensorial, and intellectual abilities and having corresponding knowledge and experience. Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety.
Extend the life of the device by regular breaks in operation and avoid switching it on and off frequently. This device is not suitable for continuous use.
Giga Bar LED 240 RGB 30°
LED bar
11
Safety instructions
Safety
DANGER!
Danger for children
Ensure that plastic bags, packaging, etc. are disposed of properly and are not within reach of babies and young children. Choking hazard!
Ensure that children do not detach any small parts (e.g. knobs or the like) from the unit. They could swallow the pieces and choke!
Never let children unattended use electrical devices.
12 Giga Bar LED 240 RGB 30°
LED bar
Safety instructions
DANGER!
Electric shock caused by high voltages inside
Within the device there are areas where high voltages may be present. Never remove any covers.
There are no user-serviceable parts inside.
Do not use the device if covers, protectors or optical components are missing or damaged.
DANGER!
Electric shock caused by short-circuit
Always use proper ready-made insulated mains cabling (power cord) with a pro‐ tective contact plug. Do not modify the mains cable or the plug. Failure to do so could result in electric shock/death or fire. If in doubt, seek advice from a regis‐ tered electrician.
Giga Bar LED 240 RGB 30°
LED bar
13
Safety instructions
WARNING!
Eye damage caused by high light intensity
Never look directly into the light source.
WARNING!
Risk of epileptic shock
Strobe lighting can trigger seizures in photosensitive epilepsy. Sensitive persons should avoid looking at strobe lights.
NOTICE!
Risk of fire
Do not block areas of ventilation. Do not install the device near any direct heat source. Keep the device away from naked flames.
14 Giga Bar LED 240 RGB 30°
LED bar
Safety instructions
NOTICE!
Operating conditions
This device has been designed for indoor use only. To prevent damage, never expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and strong vibrations.
Only operate the device within the ambient conditions specified in the chapter
‘Technical specifications’ of this user manual. Avoid heavy temperature fluctua‐ tions and do not switch the device on immediately after it was exposed to tem‐ perature fluctuations (for example after transport at low outside temperatures).
Dust and dirt inside can damage the unit. When operated in harmful ambient conditions (dust, smoke, nicotine, fog, etc.), the unit should be maintained by qualified service personnel at regular intervals to prevent overheating and other malfunction.
Giga Bar LED 240 RGB 30°
LED bar
15
Safety instructions
NOTICE!
Power supply
Before connecting the device, ensure that the input voltage (AC outlet) matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker. Failure to do so could result in damage to the device and possibly injure the user.
Unplug the device before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire.
NOTICE!
Possible damage due to installation of a wrong fuse
The use of different types of fuses can cause serious damage to the unit. Fire hazard!
Only fuses of the same type may be used.
16 Giga Bar LED 240 RGB 30°
LED bar
3 Features
Features
The LED bar is particularly suitable for professional lighting tasks, for example at events, on rock stages, in theatres and musicals. It's characterized by low power consumption and long service life.
Special features of the device: n 240 × LEDs (96 × red, 72 × green, 72 × blue, each 10 mm) in eight segments n Control via DMX (4 different modes), via buttons and display on the unit as well as an optionally available IR remote control (item no. 354223) n 21 preprogrammed automatic shows n Sound control n Master / Slave mode n Robust metal housing n optionally available case for four LED bars (item no. 309617)
Giga Bar LED 240 RGB 30°
LED bar
17
Features
For technological reasons, the light output of LEDs decreases over their lifetime. This effect increases with higher operating temperature. You can extend the service life of the illuminants by providing adequate ventilation and operating the LEDs with the lowest possible brightness.
18 Giga Bar LED 240 RGB 30°
LED bar
4 Installation
Mounting options
Installation
Unpack and check carefully there is no transportation damage before using the unit. Keep the equipment packaging. To fully protect the product against vibration, dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage, respectively.
You can install the unit in hanging or standing position. When in use, the device must always be attached to a solid surface or an approved truss. Use the openings of the brackets for fixing.
Always work from a stable platform whenever installing, moving or servicing the unit. In doing so, the area underneath the unit must be cordoned off.
The safety rope must be attached to both brackets.
Giga Bar LED 240 RGB 30°
LED bar
19
Installation
WARNING!
Risk of injury caused by falling objects
Make sure that the installation complies with the standards and rules that apply in your country. Always secure the device with a secondary safety attachment, such as a safety cable or a safety chain.
NOTICE!
Risk of overheating
The distance between light output and the illuminated surface must be more than 1.5 m (19.7in).
Provide sufficient ventilation.
The ambient temperature must always be below 40 °C (104 °F).
20 Giga Bar LED 240 RGB 30°
LED bar
Installation
NOTICE!
Use of stands
When mounting the device onto a stand, ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the maximum permissible load capacity of the stand.
NOTICE!
Possible data transmission errors
For error-free operation make use of dedicated DMX cables and do not use ordi‐ nary microphone cables.
Never connect the DMX input or output to audio devices such as mixers or ampli‐ fiers.
Giga Bar LED 240 RGB 30°
LED bar
21
Installation
Please note that this device must not be connected to a dimmer.
22 Giga Bar LED 240 RGB 30°
LED bar
5 Starting up
Starting up
Create all connections while the device is off. Use the shortest possible high-quality cables for all connections. Take care when running the cables to prevent tripping hazards.
Giga Bar LED 240 RGB 30°
LED bar
23
Starting up
Connections in DMX mode Connect the DMX input of the device to the DMX output of a DMX controller or another DMX device. Connect the output of the first DMX device to the input of the second one, and so on to form a daisy chain. Always ensure that the output of the last DMX device in the daisy chain is terminated with a resistor (110 Ω, ¼ W).
24 Giga Bar LED 240 RGB 30°
LED bar
DMX indicator
Connections in master/slave mode
Starting up
If the indicator is flashing in the DMX mode, no DMX signal is received. Maybe the DMX con‐ troller is not switched on or there is a cabling error. If the indicator lights permanently, the device receives a valid DMX signal.
When you configure a group of devices in master/slave mode, the first unit will control the other units for an automatic, sound-activated, synchronized show. This function is ideal when you want to start a show immediately. Connect the DMX output of the master device to the
DMX input of the first slave device. Then connect the DMX output of the first slave device to the DMX input of the second slave device and so on.
Giga Bar LED 240 RGB 30°
LED bar
25
Connections and operating elements
6 Connections and operating elements
26 Giga Bar LED 240 RGB 30°
LED bar
Connections and operating elements
1 Locking screws for the mounting bracket
2 Mounting bracket
3 [POWER IN]
IEC chassis plug for operating voltage supply with fuse holder
4 Display
5 [MODE]
Activates the main menu and toggles between menu items.
6 [SETUP]
Selects an option of the respective operating mode.
7 [UP]
Navigates upwards in a menu list. Increases the displayed value by one.
8 [DOWN]
Navigates downwards in a menu list. Decreases the displayed value by one.
Giga Bar LED 240 RGB 30°
LED bar
27
Connections and operating elements
9 [DMX IN]
DMX input.
10 [DMX OUT]
DMX output
11 [POWER Out]
IEC chassis socket for the power supply cable to the next unit.
28 Giga Bar LED 240 RGB 30°
LED bar
IR remote control
Connections and operating elements
IR remote control is optional accessory and not included.
Giga Bar LED 240 RGB 30°
LED bar
29
Connections and operating elements
12 [AUTO]
Enables the Auto mode
13 [PRG]
Enables the Programme mode. Select the desired programme with the buttons [+] and [–] .
14 [ON/OFF]
Activates / deactivates the device
15 [SPEED]
Activates the setting mode for the programme speed. Adjust the speed using the buttons [+] and [–] .
16 [SOUND]
Activates the sound control
17 [STROBE]
Turns the strobe function on / off
18 [+]
Increases the set value by one
30 Giga Bar LED 240 RGB 30°
LED bar
19 [–]
Decreases the set value by one
20 [Dimming]
Enables the dimmer function
21 [0 … 9]
Numeric buttons for direct selection of a constant colour.
22 [R] , [G] , [B] , [A] , [W]
Buttons to select a colour tone for the dimmer mode
Connections and operating elements
Giga Bar LED 240 RGB 30°
LED bar
31
Connections and operating elements
Inserting the battery into the remote control
Press the lock of the battery holder to the centre of the housing and pull out the battery holder like a drawer. Insert the battery. The battery is correct if the positive pole points to the housing base of the remote control. Slide the battery holder back into the remote until it clicks into place.
When shipping, the battery is already installed in the remote and protected against discharge by a transparent plastic foil. Remove the plastic foil prior to first use.
32 Giga Bar LED 240 RGB 30°
LED bar
Operating
7 Operating
7.1 Starting the device
Connect the device to the power supply to start operation. After a few seconds, the display indicates that a reset is in progress. The device is then ready for use.
7.2 Main menu
Press [MODE] to activate the main menu and select an operating mode. Use [UP] and [DOWN] to change the respectively indicated value. When the display shows the desired value press
[MODE] .
If you don't press any button for about 30 seconds, the current setting will be automatically applied and the display turns off. The set values are retained as long as the device is connected to the mains power supply.
Giga Bar LED 240 RGB 30°
LED bar
33
Operating
Operating mode ‘Built-in auto‐ matic show’
A built-in automatic show can only be activated when the unit is operating in stand-alone mode or as master in a master / slave combination. This setting is only relevant if the device is not controlled via DMX.
Press [MODE] repeatedly until the display shows ‘Prxx’ . Now you can select one of the preprog‐ rammed automatic shows. Use [UP] and [DOWN] to select a value between ‘Pr01’ and ‘Pr21’ .
For programmes Pr20 and Pr21 you can set a static colour across all segments (background colour) or a colour that lights up segment-wise (hopping colour). Press [SETUP] repeatedly until the display shows ‘1xxx’ (background colour) or ‘2xxx’ (hopping colour), respectively. With
[UP] and [DOWN] you can choose from the following options:
Display
‘--r’
‘-rg’
‘--g’
‘-gb’
‘--b’
Meaning
Red
Red and green
Green
Green and blue
Blue
34 Giga Bar LED 240 RGB 30°
LED bar
Operating
Display
‘-rb’
‘rgb’
‘ OFF’
Meaning
Red and blue
Red and green and blue
LEDs off
To adjust the speed of the selected automatic show, press [SETUP] repeatedly until the display shows ‘SPxx’ . With [UP] and [DOWN] you can now select a value between ‘SP01’ (slow) and
‘SP99’ (fast) as well as ‘SPFL’ (flash effect).
To adjust the strobe frequency, press [SETUP] repeatedly until the display shows ‘FSxx’ . With
[UP] and [DOWN] you can now select a value between ‘SPFS00’ (slow) and ‘FS99’ (fast).
To adjust the fade speed of the selected automatic show, press [SETUP] repeatedly until the display shows ‘Fdxx’ . With [UP] and [DOWN] you can now select a value between ‘Fd00’ (slow) and ‘Fd99’ (fast).
Wait about 30 seconds until the display turns dark. Then the settings have been applied. To return to the parent menu without making changes, press [MODE] .
Giga Bar LED 240 RGB 30°
LED bar
35
Operating
Operating mode ‘Automatic’ Automatic operation can only be activated when the unit is operating in stand alone mode or as master in a master / slave combination. This setting is only relevant if the device is not con‐ trolled via DMX.
Press [MODE] repeatedly until the display shows ‘Auto’ .
To adjust the speed of the automatic mode, press [SETUP] repeatedly until the display shows
‘SPxx’ . With [UP] and [DOWN] you can now select a value between ‘SP01’ (slow) and ‘SP99’
(fast) as well as ‘SPFL’ (flash effect).
To adjust the strobe frequency of the automatic mode, press [SETUP] repeatedly until the dis‐ play shows ‘FSxx’ . With [UP] and [DOWN] you can now select a value between ‘SPFS00’ (slow) and ‘FS99’ (fast).
To adjust the fade speed of the automatic mode, press [SETUP] repeatedly until the display shows ‘Fdxx’ . With [UP] and [DOWN] you can now select a value between ‘Fd00’ (slow) and
‘Fd99’ (fast).
Wait about 30 seconds until the display turns dark. Then the settings have been applied. To return to the parent menu without making changes, press [MODE] .
36 Giga Bar LED 240 RGB 30°
LED bar
DMX address
Operating
This setting is only relevant when the device is controlled via DMX.
Press [MODE] repeatedly until the display shows ‘dxxx’ .
Now you can set the number of the first DMX channel to be used by the device (DMX address).
Use [UP] and [DOWN] to select a value between 1 and 512 (the display shows ‘d001’ … ‘d512’ ).
Make sure that this number matches the configuration of your DMX controller. The following table shows the highest possible first DMX address for the various DMX modes.
Mode
2-channel
3-channel
5-channel
24-channel
Highest possible DMX address
511
510
508
489
Wait about 30 seconds until the display turns dark. Then the settings have been applied. To return to the parent menu without making changes, press [MODE] .
Giga Bar LED 240 RGB 30°
LED bar
37
Operating
DMX mode
Operating mode ‘Slave’
This setting is only relevant when the device is controlled via DMX.
Press [MODE] repeatedly until the display shows ‘dxxx’ . Press [SETUP] . With [UP] and [DOWN] you can now select one of the following DMX operating modes: n ‘2-ch’ (two channels) n ‘3-ch’ (three channels) n ‘5-ch’ (five channels) n ‘24Ch’ (twenty-four channels)
Wait about 30 seconds until the display turns dark. Then the settings have been applied. To return to the parent menu without making changes, press [MODE] .
This setting is only relevant if the device is serving as Slave in a Master / Slave configuration and is not controlled via DMX.
Press [MODE] repeatedly until the display shows ‘SLAv’ .
Wait about 30 seconds until the display turns dark. Then the settings have been applied. To return to the parent menu without making changes, press [MODE] .
38 Giga Bar LED 240 RGB 30°
LED bar
Sound control and microphone sensitivity
Operating
A sound controlled automatic show can only be activated when the unit is operating in stand alone mode or as master in a master / slave combination. This setting is only relevant if the device is not controlled via DMX.
Press [MODE] repeatedly until the display shows ‘SUxx’ . This activates a sound controlled auto‐ matic show.
Now you can adjust the sensitivity of the built-in microphone for sound control. Use [UP] and
[DOWN] to select a value between 0 (low sensitivity) and 31 (high sensitivity), the display shows ‘SU00’ … ‘SU31’ .
Wait about 30 seconds until the display turns dark. Then the settings have been applied. To return to the parent menu without making changes, press [MODE] .
Giga Bar LED 240 RGB 30°
LED bar
39
Operating
Constant unicoloured pattern A constant unicoloured pattern can only be activated when the unit is operating in stand alone mode or as master in a master / slave combination. This setting is only relevant if the device is not controlled via DMX.
Press [MODE] repeatedly until the display shows ‘Colr’ .
Press [SETUP] . With [UP] and [DOWN] you can choose from the following options:
Display
‘I--r’
‘2-rg’
‘3--g’
‘4-gb’
‘5--b’
‘6-rb’
Meaning
Red
Red and green
Green
Green and blue
Blue
Red and blue
40 Giga Bar LED 240 RGB 30°
LED bar
Operating
Display
‘7rgb’
‘ OFF’
Meaning
Red and green and blue
LEDs off
To adjust the strobe frequency, press [SETUP] repeatedly until the display shows ‘FSxx’ . With
[UP] and [DOWN] you can now select a value between ‘SPFS00’ (slow) and ‘FS99’ (fast).
Wait about 30 seconds until the display turns dark. Then the settings have been applied. To return to the parent menu without making changes, press [MODE] .
Giga Bar LED 240 RGB 30°
LED bar
41
Operating
7.3 Menu overview
42 Giga Bar LED 240 RGB 30°
LED bar
Operating
Giga Bar LED 240 RGB 30°
LED bar
43
Operating
44 Giga Bar LED 240 RGB 30°
LED bar
Operating
7.4 Functions in 2-channel DMX mode
Channel
1
2
Value
0…7
8…15
16…23
24…31
32…39
40…47
48…55
Function
LEDs off
Constant unicoloured pattern in red
Constant unicoloured pattern in red and green
Constant unicoloured pattern in green
Constant unicoloured pattern in blue and green
Constant unicoloured pattern in blue
Constant unicoloured pattern in blue and red
56…63
64…231
Constant unicoloured pattern in red, green and blue
Built-in automatic show programmes
232…255 Sound-controlled show
Function depending on setting of channel 1
Giga Bar LED 240 RGB 30°
LED bar
45
Operating
Channel Value
Channel 1 = 0…63
Function
No function
Channel 1 = 64…231
0…255 Increasing speed
Channel 1 = 232…255
0…255 Sensitivity of the built-in microphone for sound control
46 Giga Bar LED 240 RGB 30°
LED bar
7.5 Functions in 3-channel DMX mode
2
3
Channel
1
Value
0…255
0…255
0…255
Function
Intensity (0 % to 100 %) of the 96 red LEDs
Intensity (0 % to 100 %) of the 72 green LEDs
Intensity (0 % to 100 %) of the 72 blue LEDs
Operating
Giga Bar LED 240 RGB 30°
LED bar
47
Operating
7.6 Functions in 5-channel DMX mode
4
5
2
3
Channel
1
Value
0…255
0…255
0…255
0…255
0…255
Function
Intensity (0 % to 100 %) of the 96 red LEDs
Intensity (0 % to 100 %) of the 72 green LEDs
Intensity (0 % to 100 %) of the 72 blue LEDs
Dimmer (0 % to 100 %), for all LEDs
Strobe effect, increasing speed
48 Giga Bar LED 240 RGB 30°
LED bar
Operating
7.7 Functions in 24-channel DMX mode
8
9
10
11
6
7
4
5
2
3
Channel
1
Value
0…255
0…255
0…255
0…255
0…255
0…255
0…255
0…255
0…255
0…255
0…255
Function
Intensity (0 % bis 100 %) of the red LEDs in the 1. Segment
Intensity (0 % bis 100 %) of the green LEDs in the 1. Segment
Intensity (0 % bis 100 %) of the blue LEDs in the 1. Segment
Intensity (0 % bis 100 %) of the red LEDs in the 2. Segment
Intensity (0 % bis 100 %) of the green LEDs in the 2. Segment
Intensity (0 % bis 100 %) of the blue LEDs in the 2. Segment
Intensity (0 % bis 100 %) of the red LEDs in the 3. Segment
Intensity (0 % bis 100 %) of the green LEDs in the 3. Segment
Intensity (0 % bis 100 %) of the blue LEDs in the 3. Segment
Intensity (0 % bis 100 %) of the red LEDs in the 4. Segment
Intensity (0 % bis 100 %) of the green LEDs in the 4. Segment
Giga Bar LED 240 RGB 30°
LED bar
49
Operating
19
20
21
22
15
16
17
18
Channel
12
13
14
Value
0…255
0…255
0…255
0…255
0…255
0…255
0…255
0…255
0…255
0…255
0…255
Function
Intensity (0 % bis 100 %) of the blue LEDs in the 4. Segment
Intensity (0 % bis 100 %) of the red LEDs in the 5. Segment
Intensity (0 % bis 100 %) of the green LEDs in the 5. Segment
Intensity (0 % bis 100 %) of the blue LEDs in the 5. Segment
Intensity (0 % bis 100 %) of the red LEDs in the 6. Segment
Intensity (0 % bis 100 %) of the green LEDs in the 6. Segment
Intensity (0 % bis 100 %) of the blue LEDs in the 6. Segment
Intensity (0 % bis 100 %) of the red LEDs in the 7. Segment
Intensity (0 % bis 100 %) of the green LEDs in the 7. Segment
Intensity (0 % bis 100 %) of the blue LEDs in the 7. Segment
Intensity (0 % bis 100 %) of the red LEDs in the 8. Segment
50 Giga Bar LED 240 RGB 30°
LED bar
Channel
23
24
Value
0…255
0…255
Function
Intensity (0 % bis 100 %) of the green LEDs in the 8. Segment
Intensity (0 % bis 100 %) of the blue LEDs in the 8. Segment
Operating
Giga Bar LED 240 RGB 30°
LED bar
51
Technical specifications
8 Technical specifications
Light source
Optical properties
Control
Number of DMX channels
Input connections
Output connections
Power consumption
Operating supply voltage
Fuse
240 LEDs (96 ×red, 72 ×green, 72 ×blue) in eight segments
Beam angle 30°
DMX, manually via buttons and display on the unit, infrared remote control
2, 3, 5 or 24
Voltage supply
DMX control
Voltage supply
DMX control
25 W
IEC chassis plug C14
XLR chassis plug, 3-pin
IEC chassis socket C14
XLR chassis socket, 3-pin
100 – 240 V 50/60 Hz
5 mm × 20 mm, 1 A, 250 V, slow-blow
52 Giga Bar LED 240 RGB 30°
LED bar
Protection class
Mounting options
Dimensions (W × H × D)
Weight
Ambient conditions
Technical specifications
IP20 hanging, standing
1084 mm × 88.5 mm × 65 mm
2.6 kg
Temperature range
Relative humidity
0 °C…40 °C
50 %, non-condensing
Giga Bar LED 240 RGB 30°
LED bar
53
Technical specifications
Further information
Outdoor-ready
Size of the individual LEDs
Fanless
Remote control
Wireless DMX
LEDs individually controllable
Housing colour
No
10 mm
Yes
Optional
No
No black
54 Giga Bar LED 240 RGB 30°
LED bar
Plug and connection assignments
9 Plug and connection assignments
Introduction This chapter will help you select the right cables and plugs to connect your valuable equip‐ ment so that a perfect light experience is guaranteed.
Please take our tips, because especially in ‘Sound & Light’ caution is indicated: Even if a plug fits into a socket, the result of an incorrect connection may be a destroyed DMX controller, a short circuit or ‘just’ a not working light show!
DMX connections The unit offers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX input. Please refer to the drawing and table below for the pin assignment of a suitable XLR plug.
2
3
Pin
1
Configuration
Ground, shielding
Signal inverted (DMX–, ‘cold signal’)
Signal (DMX+, ‘hot signal’)
Giga Bar LED 240 RGB 30°
LED bar
55
Troubleshooting
10 Troubleshooting
NOTICE!
Possible data transmission errors
For error-free operation make use of dedicated DMX cables and do not use ordi‐ nary microphone cables.
Never connect the DMX input or output to audio devices such as mixers or ampli‐ fiers.
In the following we list a few common problems that may occur during operation. We give you some suggestions for easy troubleshooting:
56 Giga Bar LED 240 RGB 30°
LED bar
Troubleshooting
Symptom Remedy
The unit does not work, no light Check the mains connection and the main fuse.
No response to the DMX con‐ troller
1. When the display flashes, e.g. ‘d001’ switched on. Check the DMX connectors and cables for proper connection.
2. If the display is not flashing but there is still no response, check the address settings and the DMX polarity.
3. Try using another DMX controller.
, no valid DMX signal is received. Check whether the DMX controller is
4. Check whether the DMX cables run near or parallel to high-voltage cables that may cause damage or interfer‐ ence to a DMX interface circuit.
If the procedures recommended above do not succeed, please contact our Service Center. You can find the contact information at www.thomann.de
.
Giga Bar LED 240 RGB 30°
LED bar
57
Cleaning
11 Cleaning
Optical lenses Clean the optical lenses, that are accessible from the outside, regularly in order to optimize the light output. The frequency of cleaning depends on the operating environment: wet, smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device.
n Clean with a soft cloth using our lamp and lens cleaner (item no. 280122).
n Always dry the parts carefully.
58 Giga Bar LED 240 RGB 30°
LED bar
Protecting the environment
12 Protecting the environment
Disposal of the packaging mate‐ rial
For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling.
Ensure that plastic bags, packaging, etc. are properly disposed of.
Do not just dispose of these materials with your normal household waste, but make sure that they are collected for recycling. Please follow the notes and markings on the packaging.
Disposal of your old device
This product is subject to the European Waste Electrical and Electronic Equipment Directive
(WEEE) in its currently valid version. Do not dispose with your normal household waste.
Dispose of this device through an approved waste disposal firm or through your local waste facility. When discarding the device, comply with the rules and regulations that apply in your country. If in doubt, consult your local waste disposal facility.
Giga Bar LED 240 RGB 30°
LED bar
59
Notes
60 Giga Bar LED 240 RGB 30°
LED bar
Notes
Giga Bar LED 240 RGB 30°
LED bar
61
Notes
62 Giga Bar LED 240 RGB 30°
LED bar
Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.de
Download
Advertisement
Key features
240 RGB LEDs
Beam angle of 30°
DMX and stand-alone control
Various functions and effects
Perfect for stages, clubs and other applications
Frequently asked questions
The beam angle is 30°.
The bar has 240 RGB LEDs.
Yes, the bar can be controlled via DMX or stand-alone.
This information is not available in the provided manual.
This information is not available in the provided manual.