OpERATING INSTRuCTIONS AND OWNER`S MANuAl

Add to my manuals
20 Pages

advertisement

OpERATING INSTRuCTIONS AND OWNER`S MANuAl | Manualzz
Starting Serial Number: SKU-09001001
Operating Instructions
and Owner’s Manual
Model #
MH50KR, MH75KTR,
MH125KTR, MH175KTR,
MH210KTR
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
KEROSENE
FORCED-AIR HEATER
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
­— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
— Service must be performed by a qualified service agency.
This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate
combustion and ventilation air must be provided. Refer to page 3.
UL-733, &CSA/CAN3-B140.9.3
MR. HEATER, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-916-3000
03/09
70202 Rev. A
WARNING:
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING:
GENERAL HAZARD WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING
MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE
AWAY FROM THE HEATER AS RECOMMENDED BY THE
INSTRUCTIONS NEVER USE THE HEATER IN SPACES
WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN
RESULT IN DEATH, SERIOUS BODILY INJURY AND
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE,
EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS
HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC.
CONTACT THE MANUFACTURER.
WARNING:
The State of California requires the following warning:
COMBUSTION BY-PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE,
A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER
REPRODUCTIVE HARM).
WARNING:
CARBON MONOXIDE CAN KILL YOU
USING A PORTABLE GAS CAMPING HEATER INSIDE A
TENT, RV, CAMPER, VEHICLE, SHELTER OR OTHER ENCLOSED AREAS CAN PRODUCE DEADLY CARBON MONOXIDE
CONTENTS
WARNINGS.................................................................................. 2
HEATER SPECIFICATIONS.............................................................. 3
OPERATING PRECAUTIONS........................................................... 3
SAFETY PRECAUTIONS................................................................. 3
OPERATING INSTRUCTIONS......................................................... 3
MAINTENANCE, STORAGE AND SERVICE .................................... 4
TROUBLE SHOOTING................................................................... 6
WIRING DIAGRAM....................................................................... 7
PARTS LIST................................................................................... 8
EXPLODED VIEW.......................................................................... 9
WARRANTY................................................................................10
INSTRUCTIONS FOR ORDERING PARTS........................................10
WARNING:
• DO NOT USE GASOLINE, NAPHTHA OR VOLATILE
FUELS.
• STOP HEATER BEFORE ADDING FUELS.
• ALWAYS FILL OUTDOORS AWAY FROM OPEN FLAME
• DO NOT USE EXTERNAL FUEL SOURCE.
• DO NOT OPERATE HEATER WHERE FLAMMABLE
LIQUIDS OR VAPORS MAY BE PRESENT.
• DO NOT START HEATER WHEN CHAMBER IS HOT
• DO NOT START HEATER WHEN EXCESS FUEL HAS
ACCUMULATED IN THE CHAMBER.
• DO NOT PLACE COOKING UTENSILS ON TOP OF
THE HEATER.
• PLUG ELECTRICAL CORD INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE.
MH50KR & MH75KTR WARNING:
Not suitable for use on wood floors or other
combustible materials. When used the heater
should rest on a suitable insulating material at
least 1 inch thick and extending 3 feet or more
beyond the heater in all directions.
Mr. Heater, Inc. | Kerosene Forced Air Heater
2
Operating Instructions and Owner’s Manual
SPECIFICATIONS
CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Model
Burn Rate:
Fuel Rate:
Electrical Input:
Line Protection:
Min. Operating Voltage:
Pressure Setting:
Max. Outlet Temperature:
Fuel Tank Capacity:
Ignition:
Spark Generator:
Primary Safety Control:
Certification:
50KR
75KTR
50,000 Btu/hr (14.7 kW) 75,000 Btu/hr (22 kW)
0.37 gal/hr (1.4 L/hr)
0.55 gal/hr (2.1 L/hr)
115V, 60Hz, 3.5a
115V, 60Hz, 4a
10 amps
10 amps
110V
110V
3.5 psig (24 kPa)
4.2 psig (29 kPa)
1450oF (787oC)
1450oF (787oC)
4 gallons (15.1 L)
6 gallons (22.7 L)
Direct Spark, Continuous Direct Spark, Continuous
Igniter 13 kV, 10ma
Igniter 13 kV, 10ma
Solid State Control
Solid State Control
125KTR
125,000 Btu/hr (37 kW)
0.96 gal./hr (3.5 L/hr) 115V, 60Hz, 5.5a
20 amps
110V
5.5 psig (38 kPa)
1450oF (787oC)
8.45 gallons (32 L)
Direct Spark, Continuous
Igniter 13 kV, 10ma
Solid State Control
OPERATING PRECAUTIONS
OPERATING INSTRUCTIONS
UNPACKING
1. Remove heater from carton.
2. Remove all protective material which may have been applied
to the heater for shipment.
3. Check the heater for possible shipping damage. If any
damage is found immediately contact the manufacturer at
800-251-0001.
ASSEMBLY (For 125,000, 175,000 and 210,000 BTU/hr models
only, see figure 1, page 8.)
Wheels and handles are found in the shipping carton along with
mounting hardware. The wheels, axle and mounting hardware are
in a package. Tools required are a 5/16” nut driver, 3/8” open or
adjustable wrench and standard pliers.
1. Assemble the wheels onto the wheel support as shown.
2. Install one of the cotter pins into the hole on one end of
axle.
SAFETY PRECAUTIONS
2. 3.
4.
5.
Recommended for use with No.1-K kerosene fuel. Factory
tested for use with No.2-K kerosene, No.1 or No.2 Diesel,
No.1 or No.2 fuel oil or JP8 Jet A fuel and these fuels may
be used as well. Never use gasoline, oil drained from crank
cases, naphtha, paint thinners, alcohol or any other highly
flammable fuels.
Check the heater thoroughly for damage. DO NOT operate a
damaged heater.
DO NOT modify the heater or operate a heater which has
been modified from its original condition.
For indoor use only. Not for use where exposed to weather.
Use in well ventilated areas, provide at least 2 sq. ft. (0.19
sq. m.) of opening near the floor and 2 sq. ft. (0.19 sq. m.)
near the ceiling directly to outdoors. Increase air openings as
marked for each additional heater.
Mr. Heater, Inc.| Kerosene Forced Air Heater
210KTR
210,000 Btu/hr (61.5 kW)
1.6 gal/hr (6.0 L/hr)
115V, 60Hz, 5.5a
20 amps
110V
8.5 psig (58.6 kPa)
1450oF (787oC)
13.5 gallons (51 L)
Direct Spark, Continuous
Igniter 13 kV, 10ma
Solid State Control
6. Always keep combustibles, like paper and wood at least
8 ft. (2.4 m) from the heater outlet and 3 ft. (1.0 m) from
the top, sides and inlet. Locate 10 ft. (3.0 m) from canvas
or plastic coverings and secure them to prevent flapping
movement.
7. Caution: Due to the high surface and exhaust temperatures,
adults and children must observe clearances to avoid burns
or clothing ignition. Do Not Touch. Keep children, clothing,
and combustible away.
8. Install the heater such that it is not directly exposed to water
spray, rain and / or water.
9. Never use in areas normally for habitation and /or where
children may be present.
10. Operate only on a stable, level surface. (MH50KR &
MH75KTR – See wood floor warning).
11. Do not use with duct work. Do not restrict inlet or exit.
12. Use only with electrical power specified. The electrical
connection and grounding must comply with National
Electrical Code – ANSI/NFPA 70 (USA) and CSA C22.1
Canadian Electrical Code, Part 1 (Canada).
13. Use only a properly grounded 3-prong receptacle or
extension cord.
14. Do not move, handle, or service while hot or in operation.
15. Use only in accordance with local, state (provincial) or
national requirements, ordinances and codes.
This is a kerosene, direct-fired, forced air heater. It’s intended use
is primarily temporary heating of buildings under construction,
alteration or repair.
Direct-Fired means that all of the combustion products enter the
heated space. Even though this heater operates very close to 100
percent combustion efficiency, it still produces small amounts of
carbon monoxide. Carbon monoxide (called CO) is toxic. CO can
build up in a heated space and failure to provide adequate ventilation could result in death. The symptoms of inadequate ventilation
are:
• headache
• dizziness
• burning eyes and nose
• nausea
• dry mouth or sore throat
Be sure to follow advice about ventilation in the Safety Precautions
section.
Forced Air means that a blower or fan pushes the air through the
heater. Proper combustion depends upon this air flow; therefore,
the heater must not be revised, modified or operated with parts
removed or missing. Likewise, safety systems must not be circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people
the user is responsible for properly acquainting those present
with the safety precautions and instructions, and of the hazards
involved.
1.
175KTR
175,000 Btu/hr (51 kW)
1.3 gal/hr (5.0 L/hr)
115V, 60Hz, 5.5a
20 amps
110V
5.8 psig (40 kPa)
1450oF (787oC)
13.5 gallons (51 L)
Direct Spark, Continuous
Igniter 13 kV, 10ma
Solid State Control
3
Operating Instructions and Owner’s Manual
3. Slide the large washer, then wheel onto the axle next to the
cotter pin.
4. Slide the spacer onto the axle next to the wheel.
5. Slide the partially assembled axle through the wheel support
frame.
6. Slide the spacer onto the axle next to the wheel support.
7. Slide the wheel then large washer onto the axle and hold in
place with the remaining cotter pin.
8. Install the caps over the larger washers to finish the wheel
assembly.
MH50KR - Unplug unit. Wait 5 minutes. Plug back in.
MH75KTR, MH125KTR, MH175KTR & MH210KTR - Toggle switch to
“OFF” position, wait 5 minutes. Restart.
MAINTENANCE AND STORAGE
WARNING. To prevent personal injury, unplug the heater from the
wall outlet before servicing.
For maximum efficiency and trouble-free service, make the
following periodic maintenance, cleaning and inspections.
Adjusting Pump Pressure
Due to varying fuel viscosities and normal component wear the
pump pressure on this heater may need to be adjusted.
PREPARING FOR OPERATION
1. Check the heater for possible shipping damage. If any is
found, immediately contact the manufacturer at
800-251-0001.
2. Follow all of the “Precautions”.
3. Fill the fuel tank with clean kerosene. In extremely cold
weather, condensation may develop in the tank and it is
recommended that a tablespoon of de-icer be added for
each gallon (4 liters) of fuel in the tank. When filling the
heater, use at least 2 gallons (8 liters) of fuel. Be sure heater
is level and do not overfill. Use a funnel or can with a long fill
spout.
IMPORTANT: Before filling fuel tank the first time or after extended storage periods, drain the fuel tank of any moisture
or condensation.
4. Locate heater at a safe distance from combustible materials.
Models MH50KR & MH75KTR are not suitable for use on
wood floors or other combustible materials. When used, the
heater should rest on suitable insulating material at least 1
inch thick and extending 3 ft. or more beyond the heater in
all directions.
Adjustment Procedure:
1. Fill fuel tank.
2. Start heater.
3. Locate the fuel pressure adjustment screw (ref. #29) in the
exploded parts drawing. The pressure adjustment screw
is located at the rear of the heater, in the air filter housing
cover (approx.2” from the left side and 1” from the top).
Remove and discard the rubber cap (ref. #4) to expose the
screw.
4. Using a flat bladed screw driver, turn the pump pressure
adjustment screw clockwise to increase pump pressure and/
or counter-clockwise to decrease pump pressure. Base pump
pressures can be found in the specifications chart on page 3
of the “Operating Instructions and Owners’ Manual”.
5. For best results, the nose cone in the combustion chamber
should be cherry red with no dark spots and the flame
should not extend beyond the nose cone.
Improper Pressure Adjustment
Problem: Heater does not have a strong consistent flame.
Heater smokes and spits raw fuel.
Nose cone does not get cherry red.
HEATER START UP
MH50KR: Plug the heater into a grounded 115V, 60 Hz, 1 Ø
outlet.
MH75KTR, MH125KTR, MH175KTR & MH210KTR: Turn
thermostat to lowest setting, make sure “On/Off” switch
is “Off”. Plug the heater into a grounded 115V, 60 Hz, 1 Ø
outlet. Turn thermostat to highest setting. Start heater by
pushing toggle switch to “On” position (light signifies switch
is in “ON” position). Adjust thermostat to desired setting.
Heater will cycle on/off as heat is required.
EXTENSION CORD REQUIREMENTS: Up to 100’ (30.5m) use
16 awg. conductor. 101’ - 200’ (30.5 - 61.0m) use 14 awg.
conductor.
For all models:
• In cold weather (below 10° F), starting may be improved by
holding a finger over the vent hole of the pump adjustment
screw cap until the heater starts.
• This unit is equipped with an interrupt circuit. The reset is
integrated into the “On/Off” switch. If the unit does not
start, toggle the switch to “Off”, wait 5 min. and toggle
the switch to “On”.
1.
Adjustment:Pump pressure is too low.
Turn adjustment screw clockwise to increase pump pressure.
Problem:
Adjustment:Pump pressure is too high.
Turn adjustment screw counter clockwise to decrease pump pressure.
DAILY SCHEDULE
1.
GENERAL. Make general visual inspection of heater for loose
or damaged parts. Check nuts and bolts to insure against
looseness caused by vibration or rough handling. Damaged
parts should be repaired or replaced before using heater
again. Check heater operation to be sure it is operating
normally (See “Servicing” section for description of normal
operation).
2. FILTERS. Dirty air or fuel filters will cause an imbalance in
the air-fuel mixture. The best indication that this condition
exists is an increase in odors or difficulty getting your heater
to ignite. This heater should never be operated without the
filters in place. If required, clean filters as described under
“500 Hours” and “Annual Schedules”.
HEATER SHUT DOWN
1.
MH50KR: Unplug heater from power source.
MH75KTR, MH125KTR, MH175KTR & MH210KTR: Push
“On/Off” switch to “Off” position. For extended shutdown,
unplug heater from power source.
RESTART AFTER SAFETY SHUTDOWN (MH50KR, MH75KTR,
MH125KTR, MH175KTR & MH210KTR) See page 7
Mr. Heater, Inc. | Kerosene Forced Air Heater
Flame extends beyond the end of the heater.
4
Operating Instructions and Owner’s Manual
500 HOUR SCHEDULE
1.
2.
3.
4.
5.
AIR INTAKE FILTER. Remove and wash the filter element
with a mild detergent, dry thoroughly and replace. Do not
oil the filter element. If your heater is used where there
is considerable dust or dirt, clean as often as necessary
(approximately every 50 hrs.).
REMOVE DUST. Clean heater twice a season (more often
under dusty conditions). Remove accumulated dust from the
transformer, burner, motor and fan blades with compressed
air. Wipe area clean with a clean dry cloth. Inspect area to
insure all foreign materials are removed, especially around
the burner and combustion area.
CAD CELL. Clean the glass portion of the cad cell with a soft
dry cloth.
NOZZLE. Accumulation of dirt from fuel and carbon from the
compressor vanes will eventually fill up the passages in the
nozzle, resulting in reduction of fuel and air flow. Pressure
will gradually increase giving improper fuel-air mixture and
excess odor and smoke. If this occurs, replace the fuel
nozzle.
FUEL TANK. Clean twice a season (during frequently used
periods, clean twice a month). Drain and flush the fuel tank
with clean fuel oil.
ANNUAL SCHEDULE
1.
AIR OUTPUT FILTER. Remove the air output filter and tap
the contaminated side gently on a solid object to remove
contaminates. Compressed air or liquids should not be used
to clean this filter. Reinstall cleaned filter in filter body in the
same position as it was when removed. If the filter appears
extremely dirty, replace it with a new filter of the same type.
When replacing the filter cover, be sure the gasket is firmly
in place and the screws in the filter cover are tight to prevent
air leaks.
2. FUEL FILTER. Remove the fuel filter from fuel line and direct
compressed air through the filter in the opposite direction
of fuel flow. Safety glasses should be worn when using
compressed air.
3. AIR AND FUEL LINES. If the air or fuel lines are removed
during cleaning, be sure all connections are tight before
operating unit.
STORAGE
Store the heater in a dry location free from fumes or dust.
At the end of each heating season, clean the heater as described
in the MAINTENANCE section. Drain and flush the fuel tank with
clean fuel. The manufacturer recommends completely filling the
tank with fuel for extended storage to minimize condensation
inside the tank.
SERVICING
A hazardous condition may result if a heater is used that has been
modified or is not functioning properly.
When the heater is working normally:
* The flame is contained within the heater.
* The flame is essentially yellow.
* There is no strong disagreeable odor, eye burning or other
physical discomfort.
* There is no smoke or soot internal or external to the heater.
* There are no unplanned or unexplained shut downs of the
heater.
Mr. Heater, Inc.| Kerosene Forced Air Heater
5
Operating Instructions and Owner’s Manual
DIAGNOSTIC SAFETY SHUTDOWN AND TROUBLE SHOOTING
Model MH125KTR, MH175KTR and MH210KTR heaters are equipped with a diagnostic control board and flashing LED error indicator. This
flashing LED signals indicate unit operation status. See the following diagnostic guide for unit status and corrective action if necessary.
LED
UNIT OPERATION
TROUBLE SHOOTING
Steady ON
System Check
System performing self test. No action required.
Steady OFF
Operation OK
No action required.
2 Flashes
No flame detected
Heater fails to start during the first 30 sec. of operation.
1. Check wiring to motor (per wiring schematic in manual).
2. Make sure that the pressure gauge is in place and not damaged.
3. Adjust pressure for proper heater operation per manual.
4. With heater disconnected from AC source, rotate fan clockwise to verify motor is free.
5. Remove air filter housing from motor and inspect the pump rotor for damage. If damaged, replace rotor assembly.
6. If wiring is correct, pump rotor is okay, and motor is not rotating freely, replace motor or power-pack assembly.
7. If problem persists, replace oil flame control assembly.
8. Check for spark arching from the electrode assembly (ref. 50), to the combustion cylinder (ref. 39).
9. Check the cad cell (ref. 38) for continuity.
3 Flashes
High limit switch
failure
1.
Make sure heater is cooled off, press reset switch and retry.
4 Flashes
CAD Cell Failure
1.
2.
•
•
•
•
•
3.
4.
Check wiring to cad cell (per wiring schematic in manual).
Clean cad cell photo cell.
Slide cad cell out of cad cell holder.
Push the photo cell out of the black rubber cad cell housing by pushing on the 2 purple wires.
Clean the photo cell with a soft cloth and rubbing alcohol.
Pull the photo cell back into the cad cell housing and reinstall into holder.
Test heater.
If the heater still does not operate, replace cad cell.
Replace oil flame control assembly.
Power Light
Power to control
1.
Sensing power. No action required.
Model MH50KR and MH75KTR heaters are NOT equipped with a diagnostic control board or flashing LED error indicator. See the following
troubleshooting guide for unit status and corrective action if necessary.
SYMPTOM
TROUBLE SHOOTING
High limit switch Open Circuit
1)
Sparks, calling for flame, but
1)
no or slow motor operation
2)
3)
4)
5)
6)
7)
8)
9) Make sure heater is cooled off, toggle switch to “OFF” position, wait 5 minutes and retry.
No Spark
Check length and gage of extension cord for proper amp. draw. (Check requirements on page 4.)
Check wiring to igniter (per wiring schematic in manual).
Check gap between electrode probes (2.3 - 3 mm).
Still no spark, replace igniter assembly.
Replace oil flame control assembly.
1) 2)
3)
4)
5)
Check wiring to motor (per wiring schematic in manual).
Make sure that the pressure gauge is in place and not damaged.
Adjust pressure for proper heater operation per manual.
With heater disconnected from AC source, rotate fan clockwise to verify motor is free.
Remove air filter housing from motor and inspect the pump rotor for damage. If damaged, replace rotor assembly.
If wiring is correct, pump rotor is okay, and motor is not rotating freely, replace motor or power-pack assembly.
If problem persists, replace oil flame control assembly.
Check for spark arching from the electrode assembly, to the combustion cylinder.
Check the cad cell for continuity.
Abnormal Motor Operation -
1)
Motor overheats or Stops
2)
3)
4)
5)
Motor speed too low (Motor should operate at 3450rpm) - Replace motor.
With heater disconnected from AC source, rotate fan clockwise to verify motor is free.
Remove air filter housing from motor and inspect the pump rotor for damage. If damaged, replace rotor assembly.
If wiring is correct, pump rotor is okay, and motor is not rotating freely, replace motor or power-pack assembly.
Replace oil flame control assembly.
Unable to Detect Flame
1)
2)
3)
4)
Check wiring to cad cell (per wiring schematic in manual).
Clean cad cell photo cell.
a) Slide cad cell out of cad cell holder.
b) Push the photo cell out of the black rubber cad cell housing by pushing on the 2 purple wires.
c) Clean the photo cell with a soft cloth and rubbing alcohol.
d) Pull the photo cell back into the cad cell housing and reinstall into holder.
e) Test heater.
If the heater still does not operate, replace cad cell.
Replace oil flame control assembly.
Flame Control Failure
Check wiring in heater (per wiring schematic in manual).
Replace oil flame control assembly.
1)
2)
Mr. Heater, Inc. | Kerosene Forced Air Heater
6
Operating Instructions and Owner’s Manual
WIRING DIAGRAM
18AWG GRN
18AWG BLK
1
18AWG WHT
18AWG YELL
2
3
MH50KR/MH75KTR
HI-LIMIT
SWITCH
ON/OFF SWITCH
18AWG YELL
THERMOSTAT
18AWG BLUE
CAD CELL
18AWG BLK
18AWG WHT
CORD SET
75KT,125KT,175KT,210KT ONLY
18AWG GRN
H1 H2
FLAME CONTROL SCHEMATIC
(connections may not be in same
position on circuit board)
125KT,175KT,
210KT ONLY
M1
18AWG PURPLE
17AWG BLK
I2
I1
M2
18AWG PURPLE
COM1
AC OUTLET
ELECTR0DE
17AWG BLK
L
N
18AWG ORG
18AWG ORG
MOTOR
18AWG GRN
18AWG PINK
MOTOR CAPACITOR
18AWG PINK
18AWG RED
IGNITION TRANSFORMER
18AWG RED
MH125KTR/MH175KTR/MH210KTR
18AWG GRN
18AWG BLK
ON/OFF SWITCH
1
18AWG WHT
2
3
18AWG BLUE
CORD SET
18AWG BLK
18AWG WHT
18AWG BLUE
18AWG PURPLE
CAD CELL
18AWG PURPLE
AC OUTLET
9
CIRCUIT BOARD
10
11 12
24AWG BLK
18AWG GRN
24AWG RED
2
3
5
4
6
7
18AWG YELL
18AWG YELL
MOTOR
RED LED
8
17AWG BLK
17AWG BLK
1
HI-LIMIT
SWITCH
THERMOSTAT
18AWG ORG
18AWG RED
18AWG ORG
18AWG RED
ELECTR0DE
IGNITION TRANSFORMER
18AWG PINK
18AWG PINK
MOTOR CAPACITOR
have it checked.
A heater which is not working right must be repaired, but only
by a trained, experienced service person.
The parts lists and wiring diagram show the heater as it was
constructed. Do not use a heater which is different from that
shown. Heater performance is effected by air pressure setting. If there is any uncertainty about the air pressure setting,
Mr. Heater, Inc.| Kerosene Forced Air Heater
18AWG GRN
7
Operating Instructions and Owner’s Manual
PARTS LIST
Ref. Item # Item # Item # Item # Item #Description
Ref. Item # Item # Item # Item # Item #Description
MH50KR MH75KTR MH125KTRMH175KTRMH210KTR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
21036 21036 21036 21036 21036
21832 21833 21915 21834 21834
****
21883 21884 21885 21886
21807 21808 21809 21809 21809
21686 24343 24346 24346 24346
21835 21836 21837 21837 21837
24011 24011 24011 24011 24011
28779 28779 28780 28780 28780
23449 23449 23449 23449 23449
21839 21840 21841 21842 21843
21844 21846 21848 21850 21852
21854 21856 21858 21860 21862
21864 21864 21865 21865 21865
****
28788 28735 28735 28735
23725 23725 24345 24345 24345
26225 26225 26225 26225 26225
21794 21794 26901 26902 22105
F226831 F226831 F226831 F226831 F226831
19
20
21
22
23
24
25
26
27
28
****
26898 26898 26898 26898
****
22104 22104 22104 22104
26833 26833 26833 26833 26833
21810 21810 21810 21810 21810
21812 21812 21812 21812 21812
****
****
22257 22257 22257
F221887 F221887 F221887 F221887 F221887
21814 21814 21814 21814 21814
21815 21815 21815 21815 21815
F266842 F266842 F266842 F266842 F266842
Power Cord
Fuel Tank Assembly
RadiationShield Ass’y
Power Pac Ass’y
Fuel Tube
Grille Assembly
Oil cad cell Bracket
Fuel Filter
Motor Cord Sleeve
Bottom Shell
Top Shell, Burner
Top Shell, Insp. Cover
Motor Mounting Brkt
Start Capacitor
Air Tube
Snap Bushing
High Limit Control
Kit, Rotor
- Air Pump Rotor w/Vanes
- Nylon Air Pump Insert
- Nylon Pipe Plug
- Pump Adj. Screw Cap
- Ball,. Pressure adj.
- Spring, Pressure adj.
29 21866 21866
30 21816 21816
31 26903 26903
32 21882 21868
33 26909 26909
34 26910 26910
35 27339 21817
36 27790 27790
37 27421 28740
38 22142 22142
39 27416 28741
40 26223 26223
41 21819 21819
42 21820 21820
43 21821 21821
44 ****
21822
45 ****
21734
46 28785 28785
47 ****
28791
48 21830 21888
49 21892 21892
50 28786 28786
51 27094 27094
52 27095 27095
53 21813 21813
*
24171 24171
*
*
27429 27429
*
28745 28745
*
****
22146
*
****
26070
Receptacle, 110V
AC Receptacle Cover
Air Pump Cylinder
Outlet Housing
Inlet Housing
Burner Head Ass’y
Kit, Filter
Outlet Filter
Inlet Filter
Kit, Pump Adjustment
*
PARTS LIST
Item #
21867
21816
26903
21869
26909
26910
21818
28739
26885
22142
28742
26223
21819
21820
21821
21822
21734
28785
28778
21826
21893
28786
****
****
21813
****
26227
27429
****
22146
26070
21867
21816
26903
21870
26909
26910
21818
28739
26866
22142
28743
26223
21819
21820
21821
21822
21734
28785
28778
21826
21893
28786
****
****
21813
****
26227
27429
****
22146
26070
21867
21816
26903
21871
26909
26910
21818
28739
22108
22142
22109
26223
21819
21820
21821
21822
21734
28785
28778
21826
21893
28786
****
****
21813
****
26227
27429
****
22146
26070
Flame Control Ass’y
Flame Control Bracket
cad cell Flame Sensor
Comb.Chamber Cyl.Ass’y
Fuel Cap
Fuel Cap Gasket
Motor
Nozzle Adapter
Fan
Igniter Assembly
Fuel Air Aspir. Nozzle
Strain Relief Bushing
Electrode Assembly
Electrode Insulated Cover
Hose Barb Adapter
Thermostat Knob
Thermostat Assembly
ON/OFF Switch
Fuel Gauge
Control Panel
Control Panel Back
Pressure Gauge, Round
Clip Handle Mtg.
Handle
Gasket, Outlet Filter
Nozzle mtg. plate
Snap Bushing
Nozzle Ext. Retaining Ring
Fuel Line Bushing
Bracket Thermostat Mtg.
Clamp Loop
Not shown in the drawing
2
Handle and wheel assembly for MH125KTR,
MH175KTR & MH210KTR only.
Ref.
Item #
MH125KTR MH175KTR MH210KTR
1
2
*
3
*
4
5
6
7
8
9
10
11
*
22169
22172
22173
22174
22176
22177
22178
22179
28749
28750
28751
28754
21897
28787
22169
22172
22173
22174
22176
22177
22178
22179
28749
28750
28751
28754
21897
28787
MH50KR MH75KTR MH125KTRMH175KTRMH210KTR
Item #Description
22169
22172
22173
22174
22176
22177
22178
22179
28749
28750
28751
28754
21897
28787
10
Wheel Assembly, 10”
Upper Handle w/Spring Clips
Lower Handle, Right
Lower Handle, Left
Leg Support, Right
Leg Support, Left
Support Leg
Front Handle w/Axle
Large Retainer Washer
Cotter Pin
Hub Cap
Extension Cord Caddy
Wheel Spacer
Hardware Package
6
3
4
5
7
1
9
8
11
* Not shown in drawing
Figure 1.
Mr. Heater, Inc. | Kerosene Forced Air Heater
8
Operating Instructions and Owner’s Manual
Kerosene Forced Air Heater • Model MH50KR, MH75KTR, MH125KTR, MH175KTR, MH210KTR
22
27
23
9
35
28
50
25
18
21
26
51
43
53
Filter Kit
52
12
11
3
32
42
41
37
24
39
17
4
36
7
31
5
40
13
15
20
10
19
29
30
38
47
33 34
49
8
16
1
14
2
45
44
48
46
Mr. Heater, Inc.| Kerosene Forced Air Heater
9
Operating Instructions and Owner’s Manual
6
Operating Instructions
and Owner’s Manual
Model #
MH50KR, MH75KTR,
MH125KTR, MH175KTR,
MH210KTR
WARNING:
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE
DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE
AGENCY.
PARTS ORDERING INFORMATION:
PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or
direct from the factory
FOR INFORMATION REGARDING SERVICE
Please call Toll-Free 800-251-0001
www.mrheater.com
Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in
all communication.
LIMITED WARRANTY
Mr. Heater, Inc. warrants its heaters and accessories to be free from defects in
material and workmanship for a period of 1 year from date of purchase. Mr. Heater,
Inc. will repair or replace this product free of charge if it has been proven to be
defective within the 1-year period, and is returned at customer expense with proof
of purchase to Mr. Heater, Inc. within the warranty period.
Mr. Heater, Inc. reserves the right to make changes at any time, without notice or
obligation, in colors, specifications, accessories, materials and models.
MR. HEATER, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
Mr. Heater is a registered trademarks of
Enerco Technical Products, Inc.
© 2009, Enerco/Mr. Heater. All rights reserved
UL-733, &CSA/CAN3-B140.9.3
Mr. Heater, Inc. | Kerosene Forced Air Heater
10
Operating Instructions and Owner’s Manual
Guide d'utilisation
et instructions de
fonctionnement
Modèle n°
MH50KR, MH75KTR,
MH125KTR, MH175KTR,
MH210KTR
AVERTISSEMENT :
N'UTILISEZ QUE LES PIÈCES DE RECHANGE DU FABRICANT. L'UTILISATION D'AUTRES
PIÈCES RISQUE DE CAUSER DES BLESSURES ET LA MORT. LES PIÈCES DE REMPLACEMENT NE SONT OFFERTES QUE PAR LE FABRICANT ET DOIVENT ÊTRE INSTALLÉES
PAR UNE ENTREPRISE SPÉCIALISÉE.
INFORMATIONS SUR LA COMMANDE DE PIÈCES :
ACHAT : On peut se procurer des accessoires auprès de tous les détaillants locaux
Mr. Heater ou directement du fabricant.
POUR OBTENIR DES INFORMATIONS SUR LE SERVICE
Appelez sans frais au 1 800 251-0001
www.mrheater.com
Nos heures d'ouverture sont de 8 h 30 à 17 h HNE, du lundi au vendredi.
Veuillez indiquer le numéro du modèle, la date d'achat et la description du problème
dans toutes vos communications avec nous.
GARANTIE LIMITÉE
Mr. Heater, Inc. garantit ses appareils de chauffage et ses accessoires contre les
défauts de matériel et de main-d'œuvre pour une période de un an à partir de la
date d'achat. Mr. Heater Inc. réparera ou remplacera ce produit sans frais s'il est
démontré qu'il est devenu défectueux pendant la période de garantie et qu'il est
retourné à Mr. Heater Inc. aux frais de l'acheteur avec une preuve d'achat, durant la
période de garantie.
Mr. Heater Inc. se réserve le droit de modifier en tout temps, sans préavis ni
obligation, les couleurs, spécifications, accessoires, matériaux et modèles.
MR. HEATER, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 USA • (216) 916-3000
Mr. Heater est une marque déposée d'Enerco Technical Products, Inc.
© Enerco/Mr. Heater, 2009. Tous droits réservés.
UL-733, et CSA/CAN3-B140.9.3
Mr. Heater, Inc. | Appareil de chauffage à air pulsé au kérosène
10
Guide d’utilisation et instructions de fonctionnement
Appareil de chauffage à air pulsé au kérosène • Modèles MH50KR, MH75KTR, MH125KTR, MH175KTR, MH210KTR
27
22
23
9
35
28
50
25
18
21
26
51
43
53
Filter Kit
52
12
11
3
32
42
41
39
17
37
24
4
36
7
31
5
40
13
15
20
10
19
29
30
38
6
47
33 34
49
8
16
1
14
2
45
44
48
46
9
Mr. Heater, Inc. | Appareil de chauffage à air pulsé au kérosène
Guide d’utilisation et instructions de fonctionnement
LISTE DES PIÈCES
Réf. N° de pièce N° de pièce N° de pièce N° de pièce N° de pièce Description
21866
29
****
****
26833
21810
21812
****
F221887
21814
21815
F266842
19
20
21
22
23
24
25
26
27
28
21036
21832
21679
21807
21686
21835
24011
28779
23449
21839
21844
21854
21864
****
23725
26225
21794
F226831
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
MH50KR MH75KTR MH125KTRMH175KTRMH210KTR
21036
21833
22215
21808
24343
21836
24011
28779
23449
21840
21846
21856
21864
28788
23725
26225
21794
F226831
21036
21915
22216
21809
24346
21837
24011
28780
23449
21841
21848
21858
21865
28735
24345
26225
26901
F226831
21036
21834
21783
21809
24346
21837
24011
28780
23449
21842
21850
21860
21865
28735
24345
26225
26902
F226831
21036
21834
22099
21809
24346
21837
24011
28780
23449
21843
21852
21862
21865
28735
24345
26225
22105
F226831
26898
22104
26833
21810
21812
****
F221887
21814
21815
F266842
26898
22104
26833
21810
21812
22257
F221887
21814
21815
F266842
26898
22104
26833
21810
21812
22257
F221887
21814
21815
F266842
26898
22104
26833
21810
21812
22257
F221887
21814
21815
F266842
21866
21866
21866
21866
Cordon d'alimentation
Réservoir de combustible
Bouclier thermique
Boîtier d'alimentation
Canalisation du combustible
Grille
Support de cellule au cadmium
Filtre à combustible
Gaine du cordon moteur
Coque inférieure
Coque supérieure, brûleur
Coque supérieure, inspection
Support de moteur
Condensateur de démarrage
Canalisation d'air
Bague pression
Commande à maximum
Ensemble de rotor
- Rotor de pompe à air avec ailettes
- Raccord de nylon pour pompe à air
Réceptacle, 110 V
Couvercle de réceptacle
Cylindre de pompe à air
Boîtier de sortie
Boîtier d'admission
Tête de brûleur
Ensemble de rotor
Filtre de sortie
Filtre d'entrée
Ensemble de réglage de pompe
- Bouchon en nylon
- Capuchon de vis de pression
- Bille de réglage
- Ressort de réglage
Commande de flamme
Réf. N° de pièce N° de pièce N° de pièce N° de pièce N° de pièce Description
MH125KTR MH175KTR MH210KTR
22169
22172
22173
22174
22176
22177
22178
22179
28749
28750
28751
28754
21897
28787
22169
22172
22173
22174
22176
22177
22178
22179
28749
28750
28751
28754
21897
28787
MH50KR MH75KTR MH125KTRMH175KTRMH210KTR
30 21816 21816
31 26903 26903
32 21882 21868
33 26909 26909
34 26910 26910
35 27339 21817
36 27790 27790
37 27421 28740
38 22142 22142
39 27416 28741
40 26223 26223
41 21819 21819
42 21820 21820
43 21821 21821
44 ****
21823
45 ****
21734
46 21872 21872
47 ****
28791
48 21831 21891
49 21892 21892
50 28786 28786
51 27094 27094
52 27095 27095
53 21813 21813
*
24171 24171
*
*
27429 27429
*
28745 28745
*
****
22146
*
****
26070
*
LISTE DES PIÈCES
21816
26903
21869
26909
26910
21818
28739
26885
22142
28742
26223
21819
21820
21821
21823
21734
21872
28778
21827
21893
28786
****
****
21813
****
26227
27429
****
22146
26070
21816
26903
21870
26909
26910
21818
28739
26866
22142
28743
26223
21819
21820
21821
21823
21734
21872
28778
21827
21893
28786
****
****
21813
****
26227
27429
****
22146
26070
21816
26903
21871
26909
26910
21818
28739
22108
22142
22109
26223
21819
21820
21821
21823
21734
21872
28778
21827
21893
28786
****
****
21813
****
26227
27429
****
22146
26070
Support de commande de flamme
Capteur de flamme
Cyl. chambre combustion
Bouchon de réservoir
Joint de bouchon
Moteur
Adaptateur gicleur
Ventilateur
Allumeur
Embout entrée d'air
Bague réd. tension
Électrode
Couv. isolé d'électrode
Adaptateur à barbelures
Bouton thermostat
Thermostat
Interrupteur
Jauge à combustible
Panneau de commande
Panneau de comm., arrière
Manomètre
Serre-câble poignée
Poignée
Joint de filtre de sortie
Plaque de gicleur
Bague pression
Bague de retenue ext.
Bague filtre combustible
Support de thermostat
Boucle étrier
Pièces non illustrées dans le schéma.
Assemblage de la poignée et des roues
– Modèles MH125KTR, MH175KTR et
MH210KTR seulement.
Réf. N° de pièce N° de pièce N° de pièce Description
22169
22172
22173
22174
22176
22177
22178
22179
28749
28750
28751
28754
21897
28787
1
2
*
3
*
4
5
6
7
8
9
10
11
*
3
10
Roues de 10 po
Poignée supérieure
Poignée inférieure, droite
Poignée inférieure, gauche
Support de patte, droit
Support de patte, gauche
Béquille
Poignée avant avec essieu
Grande rondelle
Goupille fendue
Chapeau de moyeu
Support de rallonge électr.
Séparateur
Ensemble de quincaillerie
6
4
5
7
1
9
8
11
* Article non présenté dans le schéma.
Figure 1.
Mr. Heater, Inc. | Appareil de chauffage à air pulsé au kérosène
8
Guide d’utilisation et instructions de fonctionnement
SCHÉMA DE CÂBLAGE
VRT AWG 18
INTERRUPTEUR
MARCHE-ARRÊT
NOIR AWG 18
BLC AWG 18
1
2
3
JAUNE AWG 18
INTERRUPTEUR
COMMANDE MAX.
MH50KR/MH75KTR
JAUNE AWG 18
CORDON
D’ALIMENTATION
BLC AWG 18
NOIR AWG 18
BLEU AWG 18
THERMOSTAT
MODÈLES 75KT, 125KT, 175KT ET
210KT UNIQUEMENT
CELLULE AU
CADMIUM
VRT AWG 18
H1 H2
PRISE C.A.
SCHÉMA DE LA COMMANDE
DE FLAMME
(la position des connexions peut
différer sur le circuit imprimé)
MODÈLES 125KT,175KT
ET 210KT UNIQUEMENT
M1
M2
COM1
VIOLET AWG 18
VIOLET AWG 18
NOIR AWG 17
I2
I1
ÉLECTRODE
L
N
NOIR AWG 17
ORG AWG 18
ORG AWG 18
MOTEUR
ROSE AWG 18
CONDENSATEUR
DU MOTEUR
ROSE AWG 18
VRT AWG 18
TRANSFORMATEUR
D’ALLUMAGE
RGE AWG 18
RGE AWG 18
MH125KTR/MH175KTR/MH210KTR
18AWG GRN
18AWG BLK
ON/OFF SWITCH
1
18AWG WHT
2
3
18AWG BLUE
CORD SET
THERMOSTAT
18AWG BLUE
18AWG WHT
18AWG BLK
18AWG PURPLE
CAD CELL
18AWG PURPLE
AC OUTLET
9
10
11 12
CIRCUIT BOARD
24AWG BLK
18AWG GRN
RED LED
24AWG RED
2
1
HI-LIMIT
SWITCH
3
5
4
8
7
6
18AWG YELL
18AWG YELL
18AWG ORG
ELECTR0DE
18AWG RED
18AWG ORG
MOTOR
17AWG BLK
17AWG BLK
IGNITION TRANSFORMER
18AWG RED
18AWG PINK
MOTOR CAPACITOR
18AWG PINK
La liste des pièces et le schéma de câblage présentent l'appareil de chauffage
tel qu'il a été construit. N'utilisez pas un appareil de chauffage qui diffère de ce
qui est illustré. Le rendement de l'appareil de chauffage dépend du réglage de
la pression d'air. Si vous avez un doute au sujet de la pression d'air, faites-la
18AWG GRN
vérifier.
Si l'appareil de chauffage ne fonctionne pas correctement, il doit être réparé
uniquement par un technicien qualifié.
7
Mr. Heater, Inc. | Appareil de chauffage à air pulsé au kérosène
Guide d’utilisation et instructions de fonctionnement
DIAGNOSTIC ET DÉPANNAGE APRÈS UN ARRÊT D'URGENCE
Ces instructions s'appliquent aux modèles MH125KTR, MH175KTR et MH210KTR.
Utilisez le guide de dépannage suivant pour diagnostiquer et corriger les problèmes.
VOYANT
CAUSE
SOLUTION
1 clignotement
Verrouillage du système
1)
Assurez-vous que l'appareil est refroidi, appuyez sur le bouton de réinitialisation et essayez de nouveau. (Circuit ouvert du contacteur de commande maximale)
2 clignotements
Verrouillage du système
1)
2)
3)
4)
5)
6)
7)
8)
9) 10)
1)
2)
3)
4)
Vérifiez le câblage vers le moteur (selon le schéma de câblage du présent guide).
Assurez-vous que le bouchon du manomètre est bien en place et qu'il n'est pas endommagé.
Réglez la pression pour assurer le bon fonctionnement de l'appareil de chauffage selon les spécifications du présent guide. (étincelles, appel de flamme, mais
Débranchez l'appareil de la source d'alimentation, tournez le ventilateur dans le sens horaire le moteur ne fonctionne pas ou ne fonctionne qu'à très bas régime) pour vous assurer que le moteur peut tourner librement.
Retirez le boîtier du filtre à air du moteur et vérifiez si le rotor de la pompe présente des dommages. Le cas échéant, remplacez le rotor.
Si le câblage est adéquat, que le rotor est en bon état et que le moteur ne tourne pas librement, remplacez le moteur ou le boîtier d'alimentation.
Si le problème persiste, remplacez l'ensemble commande de flamme.
Vérifiez la formation d'arc de l'étincelle depuis l'électrode (réf. 50) jusqu'au cylindre de combustion (réf. 39).
Vérifiez la continuité de la cellule au cadmium (réf. 38).
Assurez-vous que la longueur et le calibre de la rallonge correspondent au courant d'alimentation.
Régime moteur réduit (le moteur doit tourner à 3 450 tr/min - Remplacez le moteur.
Débranchez l'appareil de la source d'alimentation, puis tournez le ventilateur dans le sens horaire pour vous assurer que le moteur tourne librement.
Retirez le boîtier du filtre à air du moteur et assurez-vous que le rotor de la pompe n'est pas endommagé. Le cas échéant, remplacez le rotor.
Si le câblage est adéquat, que le rotor est en bon état et que le moteur ne tourne pas librement, remplacez le moteur ou le boîtier d'alimentation.
Remplacez l'ensemble commande de flamme.
4 clignotements
Verrouillage du système
1)
(fonctionnement anormal du moteur - 2)
Le moteur surchauffe ou s’arrête)
3)
4)
5)
Vérifiez le câblage vers le moteur (selon le schéma de câblage du présent guide).
Vérifiez l'écart entre les pointes d'électrode (2,3 à 3 mm).
Toujours aucune étincelle; remplacez l'allumeur.
Remplacez l'ensemble commande de flamme.
3 clignotements
Verrouillage du système (aucune étincelle)
5 clignotements
Verrouillage du système
(erreur liée au bouton de réinitialisation)
1)
2)
3)
Vérifiez le câblage du bouton de réinitialisation.
Remplacez le bouton de réinitialisation.
Remplacez l'ensemble commande de flamme.
6 clignotements
Verrouillage du système
1)
Vérifiez le câblage vers la cellule au cadmium (selon le schéma de câblage du présent guide).
(impossible de détecter une flamme)
2)
Nettoyez l'élément photoélectrique de la cellule au cadmium.
a) Dégagez la cellule au cadmium de son support.
b) Dégagez l'élément photoélectrique du caoutchouc blanc du boîtier de la cellule en poussant sur les fils bleu et blanc.
c) Nettoyez l'élément photoélectrique avec un chiffon doux et de l'alcool à friction.
d) Remettez l'élément photoélectrique dans le boîtier de la cellule au cadmium, puis réinstallez le support.
e) Vérifiez le fonctionnement de l'appareil de chauffage.
3)
Si l'appareil ne fonctionne toujours pas, remplacez la cellule au cadmium.
4)
Remplacez l'ensemble commande de flamme.
Allumé en permanence Défaillance de la commande de flamme
1) Vérifiez le câblage de l'appareil de chauffage (selon le schéma de câblage du présent guide).
2)
Remplacez l'ensemble commande de flamme.
Ces instructions s'appliquent aux modèles MH50KR et MH75KTR. Utilisez le guide de dépannage suivant pour diagnostiquer et corriger les
problèmes.
1) Régime moteur trop bas (le moteur doit tourner à 3 450 tr/min) – Remplacez le moteur.
2)Débranchez l'appareil, puis tournez le ventilateur dans le sens horaire pour vérifier si le moteur tourne librement.
3)Retirez le boîtier de filtre à air du moteur et vérifiez si le rotor de la pompe présente des dommages. Le cas échéant, remplacez le rotor.
4)Si le câblage est adéquat, que le rotor est en bon état et que le moteur ne tourne pas librement, remplacez le moteur ou le boîtier d'alimentation.
5)
Remplacez l'ensemble commande de flamme.
Fonctionnement anormal du moteur –
Le moteur surchauffe ou s’arrête
1) Assurez-vous que la longueur et le calibre de la rallonge électrique sont conformes aux spécifications (voir page 4).
2)
Vérifiez le câblage vers l'allumeur (selon le schéma de câblage du présent guide).
3)
Vérifiez l'écart entre les pointes d'électrode (2,3 - 3 mm).
4)
S'il n'y a toujours pas d'étincelle, remplacez l'allumeur.
5)
Remplacez l'ensemble commande de flamme.
Aucune étincelle
1)
Vérifiez le câblage vers le moteur (selon le schéma de câblage du présent guide).
2)
Assurez-vous que le manomètre est bien en place et qu'il n'est pas endommagé.
3)Réglez la pression pour assurer le bon fonctionnement de l'appareil de chauffage selon les spécifications du présent guide.
4)Débranchez l'appareil, puis tournez le ventilateur dans le sens horaire pour vérifier si le moteur tourne librement.
5)Retirez le boîtier du filtre à air du moteur et vérifiez si le rotor de la pompe présente des dommages. Le cas échéant, remplacez le rotor.
6)Si le câblage est adéquat, que le rotor est en bon état et que le moteur ne tourne pas librement, remplacez le moteur ou le boîtier d'alimentation.
7)
Si le problème persiste, remplacez l'ensemble commande de flamme.
8)
Vérifiez si un arc électrique se produit entre l'électrode et le cylindre de combustion.
9) Vérifiez la continuité de la cellule au cadmium.
Présence d'étincelles et appel de flamme, mais
le moteur ne fonctionne pas ou tourne à très bas régime
DÉPANNAGE
1)Assurez-vous que l'appareil est refroidi, placez l'interrupteur à « OFF », attendez 5 minutes et redémarrez l'appareil.
SYMPTÔME
Circuit ouvert du contacteur de commande maximale
La flamme n'est pas détectée
1)Vérifiez le câblage vers la cellule au cadmium (selon le schéma de câblage du présent guide).
2)
Nettoyez l'élément photoélectrique de la cellule au cadmium.
a) Dégagez la cellule au cadmium de son support.
b) Dégagez l'élément photoélectrique du caoutchouc noir du boîtier de la cellule en poussant sur les 2 fils violets.
c) Nettoyez l'élément photoélectrique avec un chiffon doux et de l'alcool à friction.
d) Remettez l'élément photoélectrique dans le boîtier de la cellule au cadmium, puis réinstallez le support.
e) Vérifiez le fonctionnement de l'appareil de chauffage.
3)
Si l'appareil ne fonctionne toujours pas, remplacez la cellule au cadmium.
4)Remplacez l'ensemble commande de flamme.
Défaillance de la commande de flamme
1)Vérifiez le câblage de l'appareil de chauffage (selon le schéma de câblage du présent guide).
2)Remplacez l'ensemble commande de flamme.
Mr. Heater, Inc. | Appareil de chauffage à air pulsé au kérosène
6
Guide d’utilisation et instructions de fonctionnement
2.
une description du fonctionnement normal).
FILTRES. Les filtres à air et à combustible doivent être propres
pour assurer l'équilibre du mélange air-combustible. À défaut de
quoi, l'odeur augmentera et l'appareil de chauffage démarrera
difficilement. Ne faites pas fonctionner l'appareil sans les filtres.
Si nécessaire, nettoyez les filtres tel qu'il est décrit aux sections
« Programme 500 heures » et « Programme annuel ».
PROGRAMME 500 HEURES
1.
2.
3.
4.
5.
FILTRE D'ADMISSION D'AIR. Enlevez le filtre et lavez-le à l'aide d'un
détergent doux. Séchez-le à fond et remettez-le en place. Ne huilez
pas l'élément filtrant. Si vous utilisez l'appareil dans un endroit
contenant beaucoup de poussières et de saletés, nettoyez le filtre
aussi souvent que requis (aux 50 heures environ).
ENLÈVEMENT DE LA POUSSIÈRE. Nettoyez l'appareil de chauffage
deux fois par saison (plus souvent dans les endroits poussiéreux).
Enlevez la poussière accumulée sur le transformateur, le brûleur, le
moteur et les pales du ventilateur à l'aide d'un jet d'air comprimé.
Essuyez les surfaces avec un chiffon sec et propre. Inspectez ces
endroits pour vous assurer que toute matière étrangère a été
enlevée, particulièrement autour du brûleur et de la zone de
combustion.
CELLULE AU CADMIUM. Nettoyez la partie vitrée de la cellule au
cadmium à l'aide d'un chiffon doux et sec.
GICLEUR. L'accumulation de saleté de combustible et de carbone
causée par l'aube d'entrée obstruera éventuellement les conduits du
gicleur et entraînera une diminution du débit d'air et de combustible.
La pression augmentera graduellement, ce qui déséquilibrera le
mélange air-combustible et produira un surplus de fumée et d'odeur.
Dans un tel cas, remplacez le gicleur.
RÉSERVOIR DE COMBUSTIBLE. Nettoyez-le deux fois par saison (au
cours des périodes d'utilisation intensive, nettoyez-le deux fois par
mois). Rincez et vidangez le réservoir à l'aide de mazout propre.
ENTRETIEN
Un appareil de chauffage qui a été modifié ou qui ne fonctionne pas
correctement risque d'être une cause de dangers.
Lorsque l'appareil de chauffage fonctionne normalement :
* La flamme reste dans l'appareil de chauffage.
* La flamme est vraiment jaune.
* Il n'y a pas de forte odeur désagréable, pas de sensation de brûlure
aux yeux, ni de malaise physique général.
* Il n'y a pas de fumée ni de suie à l'intérieur ou à l'extérieur de
l'appareil de chauffage.
Il ne se produit pas d'arrêts imprévus ou inexpliqués de l'appareil.
*
PROGRAMME ANNUEL
1.
2.
3.
FILTRE DE SORTIE D'AIR. Enlevez le filtre de sortie d'air et frappez-en
doucement le côté sale sur un objet dur pour enlever les saletés.
N'utilisez pas d'air comprimé ni de liquide pour nettoyer le filtre.
Replacez le filtre propre dans son réceptacle dans la position où il
était. Si le filtre paraît extrêmement sale, remplacez-le par un autre
du même type. En remettant le couvercle du filtre en place, assurezvous que le joint d'étanchéité est solidement en place et que les vis
du couvercle sont assez serrées pour empêcher des fuites d'air.
FILTRE À COMBUSTIBLE. Enlevez le filtre de la canalisation de
combustible et dirigez de l'air comprimé à travers le filtre dans le
sens contraire du débit du combustible. Veuillez porter des lunettes
protectrices en utilisant de l'air comprimé.
CANALISATIONS D'AIR ET DE COMBUSTIBLE. Si ces canalisations
sont enlevées au cours du nettoyage, assurez-vous de bien serrer les
raccords avant de faire fonctionner l'appareil.
ENTREPOSAGE
Entreposez l'appareil de chauffage dans un endroit sec exempt de vapeurs
et de poussières.
À la fin de chaque saison, nettoyez l'appareil de chauffage tel qu'indiqué
dans la section ENTRETIEN. Rincez et vidangez le réservoir à l'aide de
combustible propre. Le fabricant recommande de remplir complètement le
réservoir de combustible avant un entreposage prolongé pour diminuer les
risques de condensation.
Mr. Heater, Inc. | Appareil de chauffage à air pulsé au kérosène
5
Guide d’utilisation et instructions de fonctionnement
dommage, avisez immédiatement le fabricant au 1 800 251-0001.
ASSEMBLAGE (Pour modèles de 125 000, 175 000 et 210 000 BTU/h
uniquement, voir la figure 1, page 8.)
Les roues et les poignées se trouvent dans la boîte avec les pièces servant
à l'assemblage. Les roues, l'essieu et les pièces servant à l'assemblage se
trouvent dans un emballage. Les outils nécessaires sont une clé de 5/16 po,
une clé ou une clé à molette de 3/8 po et une pince ordinaire.
1. Assemblez les roues sur le cadre de support tel qu'illustré.
2. Insérez l'une des goupilles fendues dans le trou situé au bout de
l'essieu.
3. Insérez la grande rondelle sur l'essieu, à côté de la goupille fendue,
puis la roue.
4. Insérez un séparateur sur l'essieu jusqu'à côté de la roue.
5. Insérez l'essieu partiellement assemblé dans le cadre de support des
roues.
6. Insérez un séparateur sur l'essieu jusqu'à côté du support de roue.
7. Insérez la roue sur l'essieu, puis la grande rondelle et fixez-les en place
avec l'autre goupille fendue.
Installez les capuchons sur les grandes rondelles pour terminer
l'assemblage des roues.
8.
AVANT LE FONCTIONNEMENT
1. Vérifiez soigneusement tout dommage qu'aurait pu subir l'appareil
de chauffage pendant l'expédition. Si vous constatez des dommages,
avisez immédiatement le fabricant au 1 800 251-0001.
2. Respectez toutes les « Précautions ».
3. Remplissez le réservoir de kérosène propre. Dans des conditions de
froid intense, il est possible que de la condensation se forme dans
le réservoir. Il est donc recommandé d'ajouter une cuillère à table
de liquide antigivrant par 4 litres (1 gallon) de combustible. Utilisez
au moins 8 litres (2 gallons) de combustible lors du remplissage du
réservoir. Assurez-vous que l'appareil de chauffage est de niveau et
que le réservoir ne déborde pas. Servez-vous d'un entonnoir ou d'un
contenant muni d'un long bec verseur.
IMPORTANT : Avant de remplir le réservoir la première fois ou après
des périodes d'entreposage prolongées, enlevez-en la condensation.
4. Placez l'appareil de chauffage à une distance sécuritaire des
matériaux combustibles. Les modèles MH50KR et MH75KTR ne sont
pas conçus pour être utilisés sur des planchers de bois ni d'autres
matériaux combustibles. Lors de son fonctionnement, l'appareil de
chauffage doit reposer sur un matériau isolant adéquat d'au moins
2,5 cm (1 po) d'épaisseur et dépassant l'appareil d'au moins 90 cm
(3 pi) ou plus de tous les côtés.
DÉMARRAGE DE L'APPAREIL
1. MH50KR : Branchez le câble d'alimentation dans une prise mise à la
terre de 115 V, 60 Hz, 1 Ø.
MH75KTR, MH125KTR, MH175KTR et MH210KTR : Réglez
le thermostat au minimum et assurez-vous que l'interrupteur est
à « OFF ». Branchez le cordon de l'appareil de chauffage dans une
prise mise à la terre de 115 V, 60 Hz, 1 Ø. Réglez le thermostat à sa
position la plus élevée. Démarrez l'appareil de chauffage en mettant
l'interrupteur à « ON » (Marche) (La lumière s’allume à la position
« ON »). Réglez le thermostat à la température désirée. L'appareil de
chauffage s'arrêtera et redémarrera au besoin.
CONDITIONS POUR UTILISER UNE RALLONGE ÉLECTRIQUE : pour
une rallonge jusqu'à 30,5 m (100 pi), conducteurs de calibre 16; pour
une rallonge de 30,5 à 61 m (101-200 pi), conducteurs de calibre 14.
Pour tous les modèles :
• Lorsque la température est inférieure à -12 °C (10 °F), le démarrage
sera facilité si l'on met un doigt sur l'orifice de ventilation de la vis de
réglage de pression jusqu'à ce que l'appareil de chauffage démarre.
• Cet appareil est équipé d'un disjoncteur intégré à l'interrupteur
marche-arrêt. Si l'appareil ne démarre pas, placez l'interrupteur
Mr. Heater, Inc. | Appareil de chauffage à air pulsé au kérosène
4
à « OFF », attendez 5 minutes et placez-le à « ON ».
ARRÊT DE L'APPAREIL
1.
MH50KR : Débranchez l'appareil.
MH75KTR, MH125KTR, MH175KTR et MH210KTR : Placez
l'interrupteur à « OFF ». Pour un arrêt prolongé, débranchez l'appareil
de chauffage de sa source d'alimentation.
REDÉMARRAGE APRÈS UN ARRÊT D'URGENCE (MH50KR, MH75KTR,
MH125KTR, MH175KTR et MH210KTR) Voir page 7.
MH50KR : Débranchez l'appareil, attendez cinq minutes puis rebranchez
l'appareil.
MH75KTR, MH125KTR, MH175KTR et MH210KTR : Placez l'interrupteur
à « OFF », attendez 5 minutes puis démarrez l'appareil.
ENTRETIEN ET ENTREPOSAGE
AVERTISSEMENT. Pour éviter toute blessure, débranchez l'appareil de
chauffage de la prise murale avant d'en effectuer l'entretien.
Pour optimiser le fonctionnement et éviter les problèmes, effectuez
régulièrement les inspections, le nettoyage et l'entretien suivants.
Réglage de pression de la pompe
En raison des variations de viscosité des combustibles et de l'usure normale
des pièces, il peut devenir nécessaire de régler la pression de la pompe.
Pour régler la pression :
1. Remplissez le réservoir.
2. Démarrez l'appareil.
3. Repérez la vis du régulateur de pression de combustible (n° 29 de
la vue éclatée). Cette vis est située à l'arrière, sous le couvercle du
boîtier de filtre à air (à environ 2 po à partir de la gauche et 1 po
à partir du haut).
4. À l'aide d'un tournevis plat, serrez la vis pour augmenter la pression
ou desserrez-la pour réduire la pression. Les pressions nominales sont
indiquées dans le tableau des spécifications à la page 3 du Guide
d'utilisation et instructions de fonctionnement.
5. Pour une efficacité maximale, le cône avant de la chambre de
combustion doit être rouge cerise sans présenter de taches foncées,
et la flamme ne doit pas se prolonger au-delà du cône.
Symptômes de réglage de pression incorrect
Problème : L'appareil ne produit pas une flamme forte et homogène.
L'appareil émet de la fumée et éjecte du combustible brut.
Le cône avant ne devient pas rouge cerise.
Cause :
La pression est trop faible.
Serrez la vis de réglage pour augmenter la pression de la
pompe.
La pression est trop forte.
Desserrez la vis pour réduire la pression de la pompe.
Cause :
La flamme dépasse l'extrémité du tube de sortie.
Problème :
PROGRAMME QUOTIDIEN
1.
GÉNÉRAL. Faites une inspection visuelle générale de l'appareil de
chauffage pour déceler les pièces endommagées ou desserrées.
Inspectez les boulons et les écrous pour vous assurer que les
vibrations et les manipulations brusques ne les ont pas desserrés.
Les pièces endommagées doivent être réparées ou remplacées
avant d'utiliser à nouveau l'appareil de chauffage. Vérifiez si l'appareil
fonctionne normalement (consultez la section « Réparation » pour
Guide d’utilisation et instructions de fonctionnement
SPÉCIFICATIONS
PRUDENCE : CSA certifié pour l’utilisation avec seulement No. 1-K le combustible de pétrole.
Modèles
MH50KR
MH75KTR
MH125KTR
MH175KTR
MH210KTR
Taux de combustion :
50 000 Btu/h (14.7 kW)
75 000 Btu/h (22 kW)
125 000 Btu/h (37 kW)
175 000 Btu/h (51 kW)
210 000 Btu/h (61,5 kW)
Consommation de
0,37 gal/h (1,4 L/h)
0,55 gal/h (2,1 L/h)
0,96 gal/h (3,5 L/h) 1,3 gal/h (5,0 L/h)
1,6 gal/h (6,0 L/h)
combustible :
Consommation électrique : 115 V, 60 Hz, 3,5 A
115 V, 60 Hz, 4 A
115 V, 60 Hz, 5,5 A
115 V, 60 Hz, 5,5 A
115 V, 60 Hz, 5,5 A
Courant maximal :
10 A
10 A
20 A
20 A
20 A
Temp. minimale 110 V
110 V
110 V
110 V
110 V
de fonctionnement :
Pression :
3,5 psig (24 kPa)
4,2 psig (29 kPa)
5,5 psig (38 kPa)
5,8 psig (40 kPa)
8,5 psig (58,6 kPa)
Température de sortie 704 oC (1 300 oF)
704 oC (1 300 oF)
704 oC (1 300 oF)
704 oC (1 300 oF)
704 oC (1 300 oF)
maximale :
Capacité du réservoir :
15,1 l (4 gal.)
22,7 l (6 gal.)
32 l (8,45 gal.)
51 l (13,5 gal.)
51 l (13,5 gal.)
Allumage :
Par étincelle, en continu Par étincelle, en continu
Par étincelle, en continu
Par étincelle, en continu
Par étincelle, en continu
Générateur d'étincelle :
Allumeur 13 kV, 10 mA
Allumeur 13 kV, 10 mA
Allumeur 13 kV, 10 mA
Allumeur 13 kV, 10 mA
Allumeur 13 kV, 10 mA
Appareil de commande :
Commande transistorisée Commande transistorisée
Commande transistorisée
Commande transistorisée
Commande transistorisée
Certification :
PRÉCAUTIONS LIÉES AU
FONCTIONNEMENT
Cet appareil de chauffage à air pulsé et à feu direct fonctionne au
kérosène. Il est destiné principalement à chauffer temporairement des
édifices en construction, en rénovation ou en réparation.
Le fonctionnement à feu direct de cet appareil signifie que tous les produits
de combustion se retrouvent dans l'air ambiant. Même si la combustion
de l'appareil de chauffage est presque complète, il produit quand même
de petites quantités de monoxyde de carbone. Le monoxyde de carbone
(appelé CO) est toxique. Il est possible que le CO s'accumule dans le local
à chauffer. Une ventilation inadéquate pourrait ainsi causer la mort. Les
symptômes ressentis en cas de ventilation inadéquate sont les suivants :
• mal de tête
• étourdissement
• sensation de brûlure au nez et aux yeux
• nausée
• mal de gorge ou bouche sèche
Assurez-vous de respecter les conseils au sujet de la ventilation mentionnés
dans la section Précautions liées à la sécurité.
Un appareil à air pulsé signifie que l'air est soufflé dans l'appareil de
chauffage par une soufflerie. La qualité de la combustion dépend du débit
d'air. Par conséquent, l'appareil de chauffage ne doit pas être modifié ni être
utilisé si des pièces sont manquantes. De même, les systèmes de sécurité ne
doivent pas être contournés ni modifiés pour faire fonctionner l'appareil.
Lorsque l'appareil de chauffage doit fonctionner en présence d'autres
personnes, l'utilisateur est responsable d'informer ces dernières des
instructions et précautions liées à la sécurité et de les avertir des dangers
inhérents.
PRÉCAUTIONS LIÉES À LA SÉCURITÉ
1. Recommandé pour l’utilisation avec le combustible de pétrole
No.1-K. L’usine évaluée pour l’utilisation avec le pétrole No.2-K, No.
1 ou le Gazole de No. 2, No. 1 ou le fuel de No. 2 ou le Jet de JP8
un combustible et ces combustibles peut être utilisée aussi. N’utilisez
jamais de l’essence, le pétrole égoutté des cas de fanatique, le
naphte, peignez thinners, de l’alcool ou autres combustibles
extrêmement inflammables.
2. Vérifiez attentivement si l'appareil de chauffage a subi des
dommages. NE FAITES PAS fonctionner un appareil endommagé.
3. NE MODIFIEZ PAS l'appareil de chauffage et ne le faites pas
fonctionner s'il n'est plus dans son état d'origine.
Pour utilisation intérieure seulement. L'appareil ne doit pas être
exposé aux intempéries.
4.
Mr. Heater, Inc. | Appareil de chauffage à air pulsé au kérosène
3
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Faites fonctionner l'appareil dans des endroits bien aérés en
laissant une ouverture d'au moins 0,19 m² (2 pi²) près du plancher
et une autre d'au moins 0,19 m² (2 pi²) près du plafond, qui
donnent directement sur l'extérieur. Augmentez la dimension de
ces ouvertures tel qu'indiqué pour chaque appareil de chauffage
additionnel.
Gardez tous les matériaux combustibles, comme le papier et le bois,
à au moins 2,4 m (8 pi) de la sortie de l'appareil de chauffage et à
1,0 m (3 pi) du dessus et des côtés de l'appareil ainsi que de la prise
d'air. Placez l'appareil à 3 m (10 pi) des toiles et des revêtements
plastiques, et fixez-les afin d'empêcher tout battement.
Attention : En raison des températures élevées à la surface et à la
sortie, les adultes et les enfants doivent respecter les distances de
sécurité pour éviter les brûlures et l'inflammation des vêtements.
Ne touchez pas à l'appareil. Gardez les enfants, les vêtements et les
produits combustibles à bonne distance de l'appareil.
Placez l'appareil de chauffage de façon à ce qu'il ne soit pas exposé
directement à l'eau.
Ne l'utilisez jamais dans des endroits qui servent normalement à
l'habitation ni où sont présents des enfants.
Utilisez uniquement sur des surfaces stables et de niveau. (Modèles
MH50KR et MH75KTR – Voir l'avertissement au sujet des planchers
de bois.)
N'utilisez pas l'appareil avec des conduits d'air. N'obstruez pas l'entrée
et la sortie d'air.
Utilisez uniquement avec l'alimentation électrique spécifiée. Le
raccordement électrique et la mise à la terre doivent être conformes
au Code national de l'électricité – ANSI/NFPA 70 (É.-U.) – et au Code
canadien de l'électricité – CSA C22.1 – partie 1 (Canada).
N'utilisez qu'avec une fiche ou une rallonge mise à la terre munie de
trois broches.
Ne déplacez pas l'appareil, ne lui touchez pas et n'essayez pas d'en
faire l'entretien lorsqu'il est chaud.
Utilisez-le uniquement en conformité avec les codes, les ordonnances
et les exigences de la province, de l'État ou de la municipalité
concernés.
INSTRUCTIONS DE FONCTIONNEMENT
DÉBALLAGE
1. Retirez l'appareil de chauffage de la boîte.
2. Enlevez tout le matériel de protection installé sur l'appareil pour le
transport.
Vérifiez soigneusement tout dommage qu'aurait pu subir l'appareil
de chauffage pendant l'expédition. Si vous constatez quelque
3.
Guide d’utilisation et instructions de fonctionnement
AVERTISSEMENT :
VOTRE SÉCURITÉ PERSONNELLE ÉTANT IMPORTANTE
POUR TOUS, VEUILLEZ LIRE LES INSTRUCTIONS AVANT
D'UTILISER CET APPAREIL DE CHAUFFAGE.
AVERTISSEMENT GÉNÉRAL DE DANGER :
LE NON-RESPECT DES MESURES DE PRÉVENTION ET
INSTRUCTIONS FOURNIES AVEC CET APPAREIL DE
CHAUFFAGE RISQUE DE CAUSER LA MORT, DES BLESSURES
GRAVES ET DES DOMMAGES OU DES PERTES MATÉRIELLES
RÉSULTANT D'INCENDIE, D'EXPLOSION, DE BRÛLURE,
D'ASPHYXIE, D'INTOXICATION AU MONOXYDE DE CARBONE
OU D'ÉLECTROCUTION.
SEULES LES PERSONNES APTES À COMPRENDRE ET À
RESPECTER LES INSTRUCTIONS DEVRAIENT UTILISER OU
EFFECTUER L'ENTRETIEN DE CET APPAREIL DE CHAUFFAGE.
SI VOUS AVEZ BESOIN D'AIDE OU D'INFORMATION AU SUJET
DE L'APPAREIL DE CHAUFFAGE (MANUEL D'INSTRUCTIONS,
ÉTIQUETTES, ETC.), VEUILLEZ COMMUNIQUER AVEC LE
FABRICANT.
AVERTISSEMENT :
LE MONOXYDE DE CARBONE PEUT VOUS TUER.
L'UTILISATION D'UN APPAREIL DE CHAUFFAGE DE
CAMPING PORTATIF À GAZ DANS UNE TENTE, UN
VÉHICULE RÉCRÉATIF, UNE ROULOTTE, UNE VOITURE,
UN ABRI OU TOUT AUTRE ENDROIT FERMÉ PRODUIT DU
MONOXYDE DE CARBONE, UN GAZ MORTEL.
AVERTISSEMENT :
• N'EMPLOYEZ PAS D'ESSENCE, DE NAPHTE OU DE
PRODUITS COMBUSTIBLES VOLATILS.
• ARRÊTEZ L'APPAREIL DE CHAUFFAGE AVANT D'Y AJOUTER
DU COMBUSTIBLE.
• REMPLISSEZ TOUJOURS LE RÉSERVOIR À L'EXTÉRIEUR,
LOIN D'UNE FLAMME NUE.
• N'UTILISEZ PAS DE SOURCE DE COMBUSTIBLE EXTERNE.
• NE FAITES PAS FONCTIONNER L'APPAREIL DE CHAUFFAGE
SI DES VAPEURS OU DES LIQUIDES INFLAMMABLES
RISQUENT D'ÊTRE PRÉSENTS.
• NE DÉMARREZ PAS L'APPAREIL DE CHAUFFAGE SI LA
CHAMBRE DE COMBUSTION EST CHAUDE.
• NE DÉMARREZ PAS L'APPAREIL DE CHAUFFAGE SI UN
SURPLUS DE COMBUSTIBLE S'EST ACCUMULÉ DANS LA
CHAMBRE DE COMBUSTION.
• NE PLACEZ PAS D'USTENSILES DE CUISSON SUR
L'APPAREIL DE CHAUFFAGE.
• BRANCHEZ LE CORDON ÉLECTRIQUE DANS UNE PRISE À
TROIS BROCHES ADÉQUATEMENT MISE À LA TERRE.
AVERTISSEMENT :
NON CONÇU POUR ÊTRE UTILISÉ DANS UNE HABITATION
OU UN VÉHICULE RÉCRÉATIF.
AVERTISSEMENT :
DANGER D'INCENDIE, D'EXPLOSION ET D'INHALATION.
CONSERVEZ LES MATÉRIAUX COMBUSTIBLES TELS QUE LES
MATÉRIAUX DE CONSTRUCTION, LE PAPIER ET LE CARTON À
UNE DISTANCE SÉCURITAIRE DE L'APPAREIL DE CHAUFFAGE
COMME LE RECOMMANDENT LES INSTRUCTIONS. N'UTILISEZ
JAMAIS L'APPAREIL DE CHAUFFAGE DANS UN LOCAL QUI
CONTIENT OU RISQUE DE CONTENIR DES PARTICULES
COMBUSTIBLES EN SUSPENSION DANS L'AIR OU DES
PRODUITS TELS QUE DE L'ESSENCE, DES SOLVANTS, DU
DILUANT À PEINTURE, DES PARTICULES DE POUSSIÈRE OU
DES PRODUITS CHIMIQUES INCONNUS.
AVERTISSEMENT :
L'État de la Californie exige que l'avertissement suivant soit fourni :
L'UTILISATION DE CET APPAREIL GÉNÈRE DES SOUSPRODUITS DE COMBUSTION CONTENANT DU
MONOXYDE DE CARBONE, PRODUIT CHIMIQUE
RECONNU PAR L'ÉTAT DE LA CALIFORNIE COMME
CAUSE DE CANCER ET D'ANOMALIES CONGÉNITALES
(OU AUTRES RISQUES POUR LA REPRODUCTION).
TABLE DES MATIÈRES
AVERTISSEMENTS........................................................................ 2
FICHE TECHNIQUE....................................................................... 3
PRÉCAUTIONS LIÉES AU FONCTIONNEMENT............................... 3
PRÉCAUTIONS LIÉES À LA SÉCURITÉ............................................ 3
INSTRUCTIONS D'UTILISATION..................................................... 3
ENTRETIEN, ENTREPOSAGE ET RÉPARATION................................. 4
DÉPANNAGE................................................................................ 6
SCHÉMA DE CÂBLAGE................................................................. 7
LISTE DES PIÈCES......................................................................... 8
VUE ÉCLATÉE............................................................................... 9
GARANTIE..................................................................................10
INSTRUCTIONS POUR LA COMMANDE DE PIÈCES......................10
AVERTISSEMENT RELATIF AUX
MODÈLES MH50KR ET MH75KTR :
Non conçu pour être utilisé sur des planchers de bois
ou d'autres matériaux combustibles. Lors de son
fonctionnement, l'appareil de chauffage doit reposer sur
un matériau isolant adéquat d'au moins 2,5 cm (1 po)
d'épaisseur et dépassant l'appareil d'au moins 90 cm (3 pi)
de tous les côtés.
Mr. Heater, Inc. | Appareil de chauffage à air pulsé au kérosène
2
Guide d’utilisation et instructions de fonctionnement
Guide d'utilisation
et instructions de
fonctionnement
Numéro de série : SKU-09001001
Modèle n°
MH50KR, MH75KTR,
MH125KTR, MH175KTR,
MH210KTR
LISEZ SOIGNEUSEMENT LES INSTRUCTIONS. Lisez et observez toutes les instructions. Conservez
les instructions pour vous y référer ultérieurement. Interdisez à quiconque n'ayant pas lu les présentes
instructions d'assembler, d'allumer, de régler ou de faire fonctionner cet appareil de chauffage.
APPAREIL DE CHAUFFAGE
À AIR PULSÉ AU KÉROSÈNE
AVERTISSEMENT : Le non-respect des instructions, telles qu'indiquées dans le
présent guide, risque d'entraîner une explosion ou un incendie entraînant des
dommages matériels ou des blessures graves, voire mortelles.
– N'entreposez pas et n'utilisez pas d'essence ou d'autres liquides ou vapeurs inflammables
à proximité de ce type d'appareil.
– L'entretien doit être effectué par un fournisseur de services d'entretien qualifié.
Cet appareil de chauffage portatif n'est pas ventilé. Il utilise l'oxygène de l'air ambiant. Une
circulation d'air adéquate doit être assurée pour la combustion et la ventilation. Voir page 3.
UL-733, et CSA/CAN3-B140.9.3
MR. HEATER, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 USA • (216) 916-3000
03/09
70202 Rev. A

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement