ATTICAT
®
PINK
FIBERGLAS
TM
®
BLOWN-IN
INSULATION
OPTIMUM R-VALUE AND
COMPLETE COVERAGE
AttiCat ® PINK ® Blown-In Insulation is an unbonded loosefill
Fiberglas™ thermal insulation. It is designed for use exclusively with the AttiCat ® machine.
Features
Applications
Standards,
Code
Compliance
• Owens Corning ® AttiCat ® PINK
(1000 sq. ft. attic with R-30)
® Blown-In Insulation covers entire attic in less than 1.5 hours
• Puts AttiCat ® Blown-in PINK for your climate zone
® Insulation where you need it, providing optimum insulating R-value
• Provides complete coverage, even around HVAC ducts, pipes, wires and outlets
AttiCat ® PINK ® Blown-In Insulation is designed for application in attics of new and existing homes.
• AttiCat ® PINK ® Blown-In Insulation is:
• Noncorrosive (per ASTM C764, section 12.7)
• Does not absorb moisture (per ASTM C1104)
• Does not support mold growth (per ASTM C1338)
• Noncombustible by the model building codes per ASTM E136
• Manufactured in accordance with ASTM C764 Type I (pneumatic application)
• R-values are determined in accordance with ASTM C687
• The surface burning characteristics of this product have been determined in accordance with:
• Flame spread <0 per ASTM E 84 1,2
• Smoke developed <0 per ASTM E 84 1,2,3
• Conforms to the quality standards of the State of California.
1.These laboratory tests are not intended to describe the hazard presented by this material under actual fire conditions.
2. Data from Underwriters Laboratories, Inc ® classified. See Classification Certificate U-197.
3. ASTM E 84 is thickness-dependent, therefore a range of values is given.
ATTICAT ® PINK ® BLOWN-IN INSULATION Nominal Bag Weight 27.5 lbs.
R-VALUE BAGS PER
R-13
R-19
R-22
R-26
R-30
R-38
R-44
R-49
R-60
1000 SQ. FT.
5.9
9
10.5
12.6
14.6
19
22.4
25
31.5
MAXIMUM
NET
COVERAGE
169.8
110.7
94.8
79.3
68.5
52.6
44.6
39.9
31.8
MINIMUM
WEIGHT / SQ.
FT.
0.162
0.248
0.29
0.347
0.402
0.523
0.616
0.688
0.866
MINIMUM
THICKNESS
(IN)
5
7
8
9.5
10.75
13.5
15.5
17
20.5
MINIMUM
SETTLED
THICKNESS 1
5
7
8
9.5
10.75
13.5
15.5
17
20.5
(MINNESOTA ONLY*)
ADDITIONAL INCHES
0
0
0.25
0.5
1.0
1.5
1.5
2.0
2.5
(MINNESOTA ONLY*)
ADDITIONAL BAGS
PER 1000 SQ. FT.
0
0
0.30
0.9
1.6
2.5
2.6
3.7
4.9
*Minnesota Administrative Code requires insulation products to provide their stated R-value(s) at Winter Design Temperatures. These columns provide the additional inches and bags.
Product Data Sheet | AttiCat ® PINK ® Blown-In Insulation | November 2018
Thermal Performance
Stated R-value is achieved by installing the minimum required number of bags per 1,000 net sq. ft. at a thickness not less than the label minimum thickness and minimum sq. ft. weight. Failure by the installer to provide both the required number of bags and at least the minimum thickness will result in lower insulation R-value.
All insulation varies in thermal performance due to factors such as mean temperature, settlement, convection, moisture absorption and installation variation. Convection in fiber glass loosefill insulation installed in open attics can reduce its thermal performance at extreme winter temperatures. AttiCat ® PINK ® Blown-In Insulation has been designed to anticipate this phenomenon and the labeled
R-value reflects the average performance over the winter heating season.
Design Considerations
Owens Corning does not recommend or approve blending or adding additional materials or adhesives to this product during installation. Owens Corning will accept no responsibility or liability when the product is not installed in accordance with the product label and installation instructions.
To help prevent fire or overheating of recessed light fixtures or similar electrical devices, do not insulate on top of or within 3 inches of such devices unless they are specifically approved to be covered by insulation. Do not place insulation in air spaces surrounding metal flues, chimneys or fireplaces. Provide minimum clearances specified in applicable NFPA standard(s), or as required by local building codes. In Canada, maintain building, electrical, gas and oil safety code required clearances between the insulation and heat emitting devices, such as fuel burning appliances, chimneys, pipes, ducts and vents to these appliances (at least 50 mm) and recessed light fixtures (at least 75 mm).
Fiberglass and Mold
As manufactured, fiberglass insulation is resistant to mold growth. However, mold growth can occur on building materials, including insulation, when it becomes contaminated with organic material and when water is present. To avoid mold growth on fiberglass insulation, remove any water that has accumulated and correct or repair the source of that water as soon as possible. Insulation that has become wet should be inspected for evidence of residual moisture and contamination, and any insulation that is contaminated should be promptly removed and replaced.
Enviromental and Sustainability
Owens Corning is a worldwide leader in building material systems, insulation and composite solutions, delivering a broad range of high-quality products and services. Owens
Corning is committed to driving sustainability by delivering solutions, transforming markets and enhancing lives. More information can be found at www.owenscorning.com.
Notes
Fiberglass products may cause temporary skin and mucous membranes itching due to the mechanical abrasion effects of fibers, a condition which is completely reversible. Owens
Corning does not recommend the use of unfaced PINK ®
Fiberglas™ Insulation in exposed applications where it will be subject to routine human contact due to this potential temporary irritation.
For additional information, refer to the Safe Use Instruction
Sheet (SUIS) found in the SDS Database via http://sds.
owenscorning.com
Certifications and Sustainable Features
• Certified by SCS Global Services to contain an
average 55% with minimum 37% post-consumer and
balance 18% pre-consumer eecycled glass content
• UL Environment GreenGuard Gold Certified.
GREENGUARD Gold Certified products are certified to
GREENGUARD Gold standards for low chemical
emissions into indoor air during product usage, and are
qualified for use in environments such as schools and
healthcare facilities. For more information, visit ul.com/gg
• UL Environment validated Formaldehyde-Free. For more
information, visit ul.com/ecv
• Environmental Product Declaration (EPD) has been
certified by UL Environment*
• Owens Corning ® Loosefill Insulation has received the
Cradle to Cradle Products Innovation Institute’s Platinum
Level Material Health Certificate. For more information,
visit c2ccertified.org
• ENERGY STAR and the ENERGY STAR mark are
registered trademarks of the U.S. Environmental
Protection Agency
• This product is participating in Declare, and is Living
Building Challenge compliant. For more information,
visit living-future.org/declare. Owens Corning ® Loosefill
Insulation is Living Product Challenge Imperative
Certified. For more information, visit living-future.org/lpc/
Disclaimer of Liability
Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient’s sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein.
OWENS CORNING INSULATING
SYSTEMS, LLC
ONE OWENS CORNING PARKWAY
TOLEDO, OHIO 43659
1-800-GET-PINK ® www.owenscorning.com
Pub. No. 10011273-E. Printed in U.S.A. November 2018. THE PINK PANTHER™ &
©1964-2018 Metro-Goldwyn-Mayer Studios Inc. All Rights Reserved.
© 2018 Owens Corning. All Rights Reserved.

Public link updated
The public link to your chat has been updated.
Advertisement