ToughRock NA Drywall Panel Use and Care Guide
Advertisement
Advertisement
Building Reputations Together ™
TOUGHROCK
Gypsum Board and Products
®
ToughRock ® Gypsum Products
Product Overview
Georgia-Pacific Gypsum constantly monitors and controls the manufacturing process to ensure gypsum product reliability and consistency. To support this commitment to customer satisfaction, Georgia-Pacific Gypsum offers limited warranties for its gypsum products. See www.gpgypsum.com for warranty details. Products are certified through testing procedures with established designations for:
ASTM Product Standards
ASTM Application Standards
CSA Standards
Additional testing has been performed on certain products indicated as:
UL Classified
ULC Classified
WHI Classified
CTC Tested
TPI Tested
Other classifications, designations and testing, which may have been performed on particular products, have been indicated where applicable in this directory.
The information contained in this directory is intended to be informative and accurate. However, it is to be used as a technical guideline and does not replace the judgments and designs of a qualified architect and/or engineer. Georgia-Pacific Gypsum is not responsible for product damage or defects resulting from incorrect application, storage, handling or abuse.
Georgia-Pacific Gypsum Products and LEED ®
Our definition at Georgia-Pacific of sustainability is meeting the needs of society today without jeopardizing our ability to do so in the future. The Georgia-Pacific Gypsum manufacturing process is influenced by our concern for the environment, our commitment to the responsible use of natural resources and doing the right thing.
In the coming years, we will continue to focus on:
• Improving energy efficiency at our manufacturing plants, with innovative technologies, that will also result in reduced green house gas emissions.
• Opportunities to reduce water use, to reuse water more effectively.
• Finding cost effective ways to further reduce air emissions.
By using recycled materials for nearly 50 years, we have found innovative ways to recover and reuse materials that otherwise would end up in landfills. We recover and reuse the wallboard that does not meet our standards and are developing beneficial applications for the very small amount of material left over at the end of each production cycle.
Green building codes, programs and standards are establishing themselves all across the country. They all promote the use of products that contribute to both the building science performance of the structure and to minimize the environmental and human health impacts of the products used in construction and over the life of the building or home. Because we are embracing sustainable practices in the manufacture of our products, architects and owners can feel good about the structures they build with our products. It is all a part of being mindful of the environment, and the social and economic impact of our products from start to finish.
Many of our products may contribute to LEED credits. To find out more, please reference the Sustainable Materials Data Sheets
(SMDS) at www.gpgypsum.com for recycled content, regional materials, low emitting materials and other potential categories for LEED credit contributions. For general information on sustainability, click the “Sustainability” tab on the website.
Architectural Specifications
Georgia-Pacific Gypsum’s 3-part guide specifications are downloadable, as rewritable Microsoft ® Word documents, in both CSI and ARCOM MasterSpec ® formats. Please visit www.gpgypsum.com for details. Downloadable specifications are also available online from Building Systems Design, Inc. at www.bsdsoftlink.com, and ARCOM
Product Masterspec at http://www.arcomnet.com/users/masterspec_sections_manufacturers.php. Georgia-Pacific
Gypsum specifications and 3-D Revit ® compatible models can also be generated in the Georgia-Pacific Design Studio at www.gpdesignstudio.com.
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
2 • For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com
ToughRock ® Gypsum Products
ToughRock
®
Gypsum Board
The federal and CSA standards, as well as certain ASTM standards, listed have been withdrawn or replaced and are provided for information only.
Product
ToughRock ® Gypsum Wallboard – For interior walls and ceilings. Accommodates wide range of decorative treatments.
Dimensions Edge Standard
TH
1/4” (6.4 mm)
3/8” (9.5 mm)
1/2” (12.7 mm)
W
4’ (1219 mm)
4’ (1219 mm)
4’ (1219 mm)
L
8’ to 12’
(2438 mm to 3658 mm)
8’ to 12’
(2438 mm to 3658 mm)
8’ to 12’
(2438 mm to 3658 mm)
5/8” (15.9 mm) 4’ (1219 mm) 8’ to 12’
(2438 mm to 3658 mm)
TE S RE B DB ASTM FEDERAL CSA
• • C 1396
C 36
SS-L-30d
• Type III
A82.27
M
• • •
• • • • C 1396
C 36
Grade R
SS-L-30d
Type III
Grade X
A82.27
M
ToughRock ® Fireguard ® Gypsum Board –
Noncombustible gypsum core. Interior wall, floor and ceiling applications. Can be used in select fire-rated assemblies. Meets basic Type X requirements.
ToughRock ® Fireguard C ™ Gypsum Board –
Use as described above. Appropriate for select commercial applications requiring extended fire resistance. Exceeds basic Type X requirements.
ToughRock ® Mold-Guard ™ (Mold-Resistant) –
For interior walls and ceiling, enhanced mold and moisture protection for high humidity areas, treated paper and moisture-treated core.
ToughRock ® Mold-Guard ™ Type X Gypsum
Board – Use as described above. Can be used in select fire-rated assemblies. Meets basic
Type X requirements.
1/2” (12.7 mm)
5/8” (15.9 mm)
4’ (1219 mm)
4’ (1219 mm)
8’ to 12’
(2438 mm to 3658 mm)
8’ to 16’
(2438 mm to 4876 mm)
1/2” (12.7 mm) 4’ (1219 mm) 8’ to 12’
(2438 mm to 3658 mm)
5/8” (15.9 mm) 4’ (1219 mm) 8’ to 12’
(2438 mm to 3658 mm)
•
•
•
•
• •
•
•
•
C 1396
C 36
C 1396
C 630
C 1396
C 630
SS-L-30d
Type III
Grade R
SS-L-30d
Type VII
Grade W
A82.27
M
A82.27
M
SS-L-30d
Type VII
Grade W, X
A82.27
M
ToughRock
®
Specialty Products
Product
ToughRock ® 54” Wide Gypsum Board – For interior walls and ceilings. Accommodates wide range of decorative treatments. Eliminates filler strip.
ToughRock ® CD ® Ceiling Board – Specially formulated core and paper ceiling board designed for water-based, textured ceiling applications. Sag resistant.
ToughRock ® Fireguard ® Soffit Board – Soffit board with treated paper face bonded to specially formulated core designed to resist sag and moisture. For exterior use such as outdoor building soffits, carports and outdoor applications where there is no direct exposure to weather.
ToughRock ® Sound Deadening Board – Use with 1/2” (12.7 mm) ToughRock Fireguard C or
5/8” (15.9 mm) ToughRock Fireguard to meet requirements for sound and fire resistance.
ToughRock ® FlexRoc ® radius curve installations including archways, columns, curved columns, curved partition walls and curved stairways.
Gypsum Board – High flex gypsum board designed for inside and outside
ToughRock ® Fireguard ® Abuse-Guard ®
Gypsum Board – Abuse-resistant gypsum board for high traffic areas where surface durability and surface indentation are important. Specifically formulated to offer greater abrasion, rubbing, scraping and gouging resistance than regular paper-faced drywall.
TH
1/2” (12.7 mm)
5/8” (15.9 mm)
1/2” (12.7 mm) 4’ (1219 mm) 12’ (3658 mm)
1/2” (12.7 mm)
5/8” (15.9 mm)
Dimensions
W
54” (1371 mm)
L
8’ to 12’
(2438 mm to 3658 mm)
54” (1371 mm)
4’ (1219 mm)
4’ (1219 mm)
8’, 9’, 10’
(2438 mm to 3048 mm)
1/4” (6.4 mm) 4’ (1219 mm) 8’ (2438 mm)
1/4” (6.4 mm) 4’ (1219 mm) 8’ (2438 mm)
5/8” (15.9 mm) 4’ (1219 mm) 12’ (3658 mm)
Edge Standard
TE S RE B DB ASTM FEDERAL CSA
• C 1396
C 36
SS-L-30d
Type III
Grade R
A82.27
M
•
•
•
•
•
•
Note: Some products are not available at all plants or locations. Call sales office listed on back cover for specific product availability.
C 1396
C 1395
C 1396
C 931
C 1396
C 442
C 1396
C 36
C 1396
C 36
SS-L-30d
Type III
Grade R
SS-L-30d
Type IV
Grade R
SS-L-30d
Type III
Grade R
SS-L-30d
Type III
Grade X
A82.27
M
A82.27
M
A82.27
M
A82.27
M
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 3
ToughRock ® Gypsum Products
Veneer Board
The federal and CSA standards, as well as certain ASTM standards, listed have been withdrawn or replaced and are provided for information only.
Product Dimensions Edge Standard
TH W L
1/2” (12.7 mm) 4’ (1219 mm) 8’ to 16’
(2438 mm to 4876 mm)
TE S RE B DB ASTM FEDERAL CSA
• C 1396
C 588
SS-L-30d
Type VI
Grade R
A82.27
M
ToughRock ® Veneer Plaster Base (Blue
Board) – Gypsum wallboard with high-suction face paper. Use in conjunction with PearlCote ™
Interior Veneer Plaster.
ToughRock ® Fireguard ®
Veneer Plaster Base –
Use as described above. Same fire rating as
ToughRock Fireguard gypsum board. UL/ULC
Classified. Type X core.
5/8” (15.9 mm) 4’ (1219 mm) 8’ to 16’
(2438 mm to 4876 mm)
• C 1396
C 588
SS-L-30d
Type VI
Grade X
A82.27
M
Joint Treatment Products
Product
ToughRock ® All-Purpose Dry Compound – Use for bedding tape, finishing joints, filling corner bead, spotting, skim coating and texturing.
Package Size
25 lb. (11 kg) bags
ToughRock ® Ready-Mix All-Purpose Joint Compound –
Pre-mixed, ready to use for bedding tape, finishing joints, skim coating and texturing.
ToughRock ® Lightweight Joint Compound – Pre-mixed, ready to use for finishing joints and cornerbead. Shrinks less and is easier to sand than
All Purpose.
ToughRock ® Semi-Light Joint Compound – Pre-mixed, ready to use for bedding tape, finishing joints, cornerbead and skim coating.
12 lb. (5.5 kg) pails
61.7 lb. (28 kg) pails
48 lb. (22 kg) carton
4.5-gallon (17 L) cartons & pails
1 gal (4 L) pail
3.5-gallon (13 L) and
4.5-gallon (17 L) cartons & pails
51 lb. (23 kg) cartons
61.7 lb. (28 kg) pail
48 lb. (22 kg) carton
ToughRock ® Ready-Mix Topping Compound – Pre-mixed and ready to use. Finish applications only. Very white in color, easy to sand.
ToughRock ® Setting Compounds – Allows complete taping and finishing in one day. Recommended for cold weather and slow drying conditions. Hardens by setting, not drying. Available 45- and 90-minute.
Ideal products for patch and repair jobs.
ToughRock ® Sandable Setting Compounds – Same use as ToughRock
Setting Compounds. Applies and sands easier than ToughRock Setting
Compounds. Available in 20-, 45- and 90-minute.
33 lb. (15 kg) bags
18 lb. (8 kg) bags
24 lb. (11 kg) bags
ToughRock ® Fire-Halt ® Sealant – A noncombustible fast-setting compound for use as a firestop sealant for penetrations such as pipes, conduit and telephone cables in fire-resistive assemblies; and as filler for the flutes in steel decks. Listed with Warnock Hersey International/
Intertek Testing Services.
ToughRock ™ Tape – Special 2-1/16” (52.4 mm) wide paper tape.
Reinforces gypsum joints. Pre-creased for ease of application.
15 lb. (7 kg) pails
33 lb. (15 kg) bags
75 ft. (22.86 m) rolls
250 ft. (76.2 m) rolls
500 ft. (152.4 m) rolls
Coverage
25 lbs. (11 kg) per 400 sq. ft. (37 m 2 ) for joints;
15–50 lbs. (7–23 kg) per
1,000 sq. ft. (93 m texturing
2 ) for
C 475
Standards
ASTM
61.7 lbs. (28 kg) per
500 sq. ft. (46 m 2 )
C 475
4.5 gallons (17 L) per
500 sq. ft. (46 m 2 )
4.5 gallons (17 L) per
500 sq. ft. (46 m 2 )
40 lbs. (18 kg) per
500 sq. ft. (46 m 2 )
1,800 sq. ft. (167 m 2 ) per 33 lb. (15 kg) bag
400’ (122 m) per
1,000 sq. ft. (93 m of gypsum board
2 )
C 475
C 475
C 475
C 475
1,000 sq. ft. (93 m 2 ) per 18 lb. (8 kg) bag
1,300 sq. ft. (121 m 2
24 lb. (11 kg) bag
) per
C 475
1 lb. (0.5 kg) powder mixed will fill 30 cubic inches (.05 m 3 )
C 475
C 475
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
4 • For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com
ToughRock ® Gypsum Products
Textures and Plaster
The federal and CSA standards, as well as certain ASTM standards, listed have been withdrawn or replaced and are provided for information only.
Product
PearlCote ™ Interior Veneer Plaster – A one-coat plaster application designed for commercial or residential use on walls or ceilings to resist abrasion or damage while maintaining mold resistance.
Package Size Coverage
50-lb. (22 kg) bag 150 2 ) per bag
ToughRock ™ Regency Ceiling Textures/Polystyrene – For spray
application only. A high-quality aggregate finish with superior ceiling
coverage. For use with gypsum board or concrete ceilings.
Not recommended for high-moisture areas such as bathrooms.
35-lb. (16 kg) bag
40-lb. (18 kg) bag
50-lb. (22 kg) bag
250 sq. ft. (23 m 2 ) per bag
285 sq. ft. (26 m 2 ) per bag
350 sq. ft. (33 m 2 ) per bag
ToughRock ™ Wall and Ceiling Texture – A decorative spray application
for both walls and ceilings. Commonly used for splatter application,
50-lb. (22 kg) bag Up 2 ) per bag depending on finish
knock-down and orange peel type textures.
Note: Some products are not available at all plants or locations. Call sales office listed on back cover for specific product availability.
Standards
ASTM
C 587
Gypsum Board Edge Details
Gypsum Board Edge Details
S
TE RE
Tapered
The tapered edge was originally called the “recessed edge.” This taper allows space for tape and joint treatment to be applied, so the completed job will be flat, smooth and monolithic. Width of taper is about 2” (51mm).
Square
Square edge was the original wallboard edge. Initially designed to be a base with a final covering such as wallpaper, paneling or tile. Now used primarily as sheathing and backer board.
Tapered with Round Edge
Round edge is designed to reduce the beading and ridging problems commonly associated with standard-type gypsum board. This edge formation provides a stronger joint when ToughRock ®
Setting Compound is used for all joint finishing steps.
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 5
ToughRock ® Gypsum Products
Where to use ToughRock
®
Gypsum Board
Product
ToughRock ®
Gypsum Wallboard
1/4”
(6.4 mm)
3/8”
(9.5 mm)
1/2”
(12.7 mm)
ToughRock ® Fireguard
Gypsum Board
®
5/8”
(15.9 mm)
ToughRock ® Fireguard C
Gypsum Board
™ 1/2”
(12.7 mm)
5/8”
(15.9 mm)
ToughRock ® Mold-Guard ™
(Mold Resistant)
1/2”
(12.7 mm)
ToughRock ® Mold-Guard ™
Type X Gypsum Board
5/8”
(15.9 mm)
ToughRock ® 54” Wide
Gypsum Board
ToughRock ® CD
Ceiling Board
®
1/2”
(12.7 mm)
5/8”
(15.9 mm)
1/2”
(12.7 mm)
X
X
X
Single Layer
Over existing walls
Masonry Wood framing
Steel framing
Interior Walls
Masonry
Base Finish
Double Layer
Wood framing
Base Finish
X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Steel framing
Base Finish
X
X
X
X
X
X
X
X
X
X
X
X
X
ToughRock
Soffit Board
ToughRock
®
®
Fireguard ®
Sound Deadening Board
1/2”
(12.7 mm)
5/8”
(15.9 mm)
1/4”
(6.4 mm)
ToughRock ® FlexRoc
Gypsum Board
®
1/4”
(6.4 mm)
ToughRock ® Fireguard ®
Abuse-Guard ®
Gypsum Board
ToughRock ®
Plaster Base
Veneer
5/8”
(15.9 mm)
1/2”
(12.7 mm)
ToughRock ® Fireguard ®
Veneer Plaster Base
5/8”
(15.9 mm)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
6 • For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com
ToughRock ® Gypsum Products
X
X
X
X
X
X
X
X
Interior of Exterior Walls
Single Layer Double Layer
Masonry
(furred)
Wood or steel framing
Rigid insulation board
Masonry
(furred)
Base Finish
Wood or steel framing
Base Finish
Over existing ceiling
Single Layer
Wood framing
Steel framing
Ceilings
Double Layer
Wood framing
Base Finish
Steel framing
Base Finish
Acoustical Base
Over suspended metal grillage
Over channel
X X X X
X
X
X X
X
X
X
X
X
X
X
X X
X
X
X
X X X X X
X
X
X
X
X
X
X
X
X
X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X
X X X X
X
X
X
X X X X X X
X
X
X X X X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X X
X
X
X
X
X
X
X
X
X X
X X X X
X X X X X
X
X
X X X X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 7
ToughRock ® Gypsum Products
Toughrock
®
Gypsum Board Physical Properties
Properties
1/4” ToughRock
Gypsum Board
® 3/8” ToughRock
Gypsum Board
®
1/2” ToughRock
Gypsum Board
® and
ToughRock ® Mold-Guard ™
Thickness, nominal inches 1/4” (6.4 mm), ± 1/64” (0.4 mm) 3/8” (9.5 mm), ± 1/64” (0.4 mm) 1/2” (12.7 mm), ± 1/64” (0.4 mm)
Width, nominal
Length, standard
Weight
Edges
1 , lbs./sq. ft. nominal (kg/m 2
Surfacing
)
4’ (1220 mm), ± 3/32” (2.4 mm) 4’ (1220 mm), ± 3/32” (2.4 mm) 4’ (1220 mm), ± 3/32” (2.4 mm)
8’ (2440 mm) to 12’ (3660 mm)
± 1/4” (6.4 mm)
8’ (2440 mm) to 12’ (3660 mm)
± 1/4” (6.4 mm)
8’ (2440 mm) to 16’ (4880 mm)
± 1/4” (6.4 mm)
1.2 (5.0)
Tapered edge
1.35 (6.1)
Tapered edge
1.39
3 (6.3), 1.65 (7.5)
100% recycled paper face, back and long edges
100% recycled paper face, back and long edges
Tapered, square or tapered with round edges
100% recycled paper face, back and long edges
Flexural strength, min.
Parallel, lbs. (N)
Perpendicular (N)
>16 (71)
>46 (205)
R Value 2 , ft 2 •°F•hr/BTU (m2•K/W) .22 est. (0.04)
Nail pull resistance, Min., lbs. (N) >36 (160)
>26 (116)
>77 (343)
.33 (0.06)
>56 (249)
>36 (160)
>107 (476)
.45 (0.08)
>77 (343)
Hardness, lbs. force (core edge & end) >15
Humidified deflection Not applicable
Packaging Two pieces per bundle, face-to-face and end taped
Surface Burning Characteristics 4
(per ASTM E 84 or CAN/ULC-S102)
Flame Spread
Smoke Developed
(The core is noncombustible when tested in accordance with ASTM E 136.)
15
0
>15
15/8” (45 mm)
Two pieces per bundle, face-to-face and end taped
15
0
>15
5/16” 3 (8 mm), 10/8” (30 mm)
Two pieces per bundle, face-to-face and end taped
15
0
Toughrock
®
Fireguard
®
Gypsum Board Physical Properties
Properties
5/8” ToughRock
Fireguard ®
®
and ToughRock
Mold-Guard ™ Type X
®
1/2” ToughRock
Fireguard C ™
® 5/8” ToughRock
Fireguard C ™
®
Thickness, nominal inches
Width, nominal
Length, standard
Weight 1 nominal, lbs./sq. ft. (Kg/m 2 )
Edges
Flexural Strength, min.
Parallel, lbf. (N)
Perpendicular, lbf. (N)
R Value 2 , ft
Packaging
2
•
°F
• hr/BTU (m 2
•
K/W)
Nail pull resistance minimum lbf. (N)
Hardness, lbf. (core, edge and end) (N)
Humidified Deflection, max in. (mm)
5/8” (15.9 mm) ±
1/64” (0.4 mm)
4’ (1220 mm)
8’ (2440 mm) to
14’ (4270 mm)
2.3 (10.0)
Tapered, Square or Rounded
50 (222)
150 (666)
.56 est. (0.10)
90 (400)
15 (67)
5/8” (16)
Two pieces per bundle, face-to-face and end taped
1/2” (12.7 mm)
4’ (1220 mm)
8’ (2440 mm) to
14’ (4270 mm)
2.0 (9.0)
Tapered, Square or Rounded
40 (178)
110 (489)
.45 (0.08)
80 (356)
15 (67)
10/8” (32)
Two pieces per bundle, face-to-face and end taped
5/8” (15.9 mm)
4’ (1220 mm)
8’ (2440 mm) to
14’ (4270 mm)
2.0 (9.0)
Tapered, Square or Rounded
50 (222)
150 (666)
.56 (0.10)
90 (400)
15 (67)
5/8” (16)
Two pieces per bundle, face-to-face and end taped
Surface Burning Characteristics
(per ASTM E 84 or CAN/ULC-S102)
Flame Spread
Smoke Developed
(The core is noncombustible when tested in accordance with ASTM E 136.)
15
0
15
0
15
0
1 Represents approximate weight for design and shipping purposes. For more exacting weight for your area, consult your local representative.
2 Tested in accordance with ASTM C 518
3 Based on new and improved, lighter and stronger ToughRock. Available from select manufacturing facilities. Call GP Gypsum Customer Service for availabilty.
NOTE: Specified minimum values are as defined in ASTM C 1396
4 New and improved, lighter and stronger ½” (12.7 mm) ToughRock has not been tested per ASTM E84 for flame spread and smoke developed.
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
8 • For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com
ToughRock ® Gypsum Products
Maximum Framing Spacing for Single-Ply Construction
1
Single-Ply ToughRock Gypsum Board Thickness Application 2 Maximum Framing Members on Centers Spacing
Ceilings: 3/8” (9.5 mm) 3
Walls:
1/2” (12.7 mm)
5/8” (15.9 mm)
1/2” (12.7 mm)
5/8” (15.9 mm)
3/8” (9.5 mm)
1/2” (12.7 mm)
5/8” (15.9 mm)
Tile Applications
3
:
Ceilings: 1/2” (12.7 mm)
5/8” (15.9 mm) perpendicular
parallel parallel
perpendicular 1
perpendicular
perpendicular
perpendicular
parallel
perpendicular
perpendicular
16” (406 mm)
16” (406 mm)
16” (406 mm)
24” (610 mm)
24” (610 mm)
16” (406 mm)
24” (610 mm)
24” (610 mm)
12” (305 mm)
16” (406 mm)
Walls: 1/2” (12.7 mm)
5/8” (15.9 mm)
perpendicular
parallel
16” (406 mm)
24” (610 mm)
1 ToughRock gypsum boards to receive hand or spray-applied water-based texture material, shall be applied perpendicular to framing. Board thickness shall
be increased from 3/8” (9.5 mm) to ½” (12.7 mm) for 16” (406 mm) o.c. framing and from ½” (12.7 mm) to 5/8” (15.9 mm) for 24” (610 mm) o.c. framing.
2 Nails for ToughRock gypsum boards applied over existing surfaces shall have a fl at head and diamond point, and shall penetrate not less than 7/8” (22 mm), nor more than 1-1/4” (32 mm) into the framing member.
3 3/8” (9.5 mm) single-ply gypsum board shall not be applied to ceilings where the gypsum board supports insulation.
Fire-Rating Information
ToughRock ® Fireguard, ® ToughRock ® Mold-Guard ™ Type X and ToughRock Fireguard C ™ gypsum board products have been classified by Underwriters Laboratories Inc. (UL) and included in numerous assembly designs investigated by UL for hourly fire resistance ratings. Several ToughRock Fireguard and ToughRock Fireguard C gypsum board products have also been listed by
Underwriters Laboratories of Canada (ULC) for inclusion in fire resistance ratings. Each UL or ULC design lists specific manufacturers and products approved for use in the assembly. Products are identified as designated Types that correlate to specific board formulations. The Type designation appears on the UL or ULC label on the product. The following tables provide a quick and easy reference to identify current ToughRock Fireguard gypsum board products and their designations in the UL or
ULC directories.
ULC Type Designation
Type 5
Type 6
Type 9
Product Name
1/2” (12.7 mm) ToughRock ® Fireguard C ™ Gypsum Board
5/8” (15.9 mm) ToughRock ® Fireguard C ™ Gypsum Board
5/8” (15.9 mm) ToughRock ® Mold-Guard ™ Type X Gypsum Board
5/8” (15.9 mm) ToughRock
5/8” (15.9 mm) ToughRock
5/8” (15.9 mm) ToughRock
®
®
®
5/8” (15.9 mm) ToughRock ®
Fireguard
Fireguard
Fireguard
Fireguard
®
®
®
®
Gypsum Board
Soffit Board
Veneer Plaster Base
Abuse-Resistant Gypsum Board
ULC Type Designation
Type Fireguard C
Type GF-2
Type GF-6
Product Name
1/2” (12.7 mm) ToughRock ®
5/8” (15.9 mm) ToughRock ®
Fireguard C ™ Gypsum Board
Fireguard C ™ Gypsum Board
5/8” (15.9 mm) ToughRock ® Mold-Guard ™ Type X Gypsum Board
5/8” (15.9 mm) ToughRock ®
5/8” (15.9 mm) ToughRock ®
Fireguard
Fireguard
®
®
Gypsum Board
Abuse-Resistant
For ToughRock Fireguard gypsum board, UL designation “Type 9” should be used for all UL and cUL assemblies, and ULC designation “Type GF-6” should be used for all ULC assemblies. Please check UL, cUL or ULC certification mark on product for confirmation prior to use. Please note that ToughRock Mold-Guard (UL Type 6 or ULC Type GF-2) may not be approved for listing in certain assemblies. Please check with UL or ULC for current information.
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 9
ToughRock ® Gypsum Products
Fire-Rating Information
continued
In addition, ToughRock ® Fireguard, ® ToughRock ® Mold-Guard ™ Type X and ToughRock Fireguard C ™ gypsum board products are classified as “Type X” in accordance with ASTM C 1396 and may be used in generic fire-rated assemblies where Type X gypsum board (as defined in ASTM C 12396) is required. Generic systems in the GA-600 Fire Resistance Design Manual are applicable to the products of any manufacturer, including Georgia-Pacific Gypsum, provided they meet certain standards set forth in such manual, such as Type X gypsum board per applicable ASTM standard with specified thickness and size described in the design.
“Type X” as used in this technical guide designates gypsum board manufactured and tested in accordance with specific ASTM standards for increased fire resistance beyond regular gypsum board. Please consult the ASTM standard for the specific product
(for example, ASTM C 1396 for gypsum board) for further information and significance of use.
It is important that you consult a design professional and the appropriate fire resistance directory or test report for complete assembly information and related information. Georgia-Pacific Gypsum does not provide architectural or engineering services. For additional fire safety information concerning Georgia-Pacific Gypsum’s products visit www.gp.com/safetyinfo.
Board Calculator
Determine the wall and ceiling areas:
Width of the room x Length of the room = Ceiling area
(Width + Length) x 2 x Height of the room = Wall area
For example, a 12’ x 16’ x 8’ room has a wall/ceiling area of 640 sq. ft.
Ceiling area: 12 x 16 = 192
Wall area: (12 + 16) x 2 x 8 = 448; 192 + 448 = 640.
Room Measurement Table
44 55 66 77 88 99 1100 1111 1122 1133 1144 1155 1166
88 224 248 272 296 320 334 368 392 416 440 464 488 512
99 244 269 294 319 344 369 394 419 444 469 494 519 544
1100 264 290 316 342 368 394 420 446 472 498 524 550 576
1111 284 311 338 365 392 419 446 473 500 527 554 581 608
1122 304 332 360 388 416 444 472 500 528 556 584 612 640
1133 324 353 382 411 440 469 498 527 556 585 614 643 672
1144 344 374 404 434 464 494 524 554 584 614 644 674 704
1155 364 395 426 457 488 519 550 581 612 643 674 705 736
1166 384 416 448 480 512 544 576 608 640 672 704 736 768
Panel Coverage Table (in sq. ft. of wall area)
4’ x 8’ Panel
4’ x 9’ Panel
4’ x 10’ Panel
4’ x 12’ Panel
4’ x 14’ Panel
4’ x 16’ Panel
1
Panel
32
36
40
48
56
64
2
Panels
64
72
80
96
112
128
3
Panels
96
108
120
144
168
192
4
Panels
128
144
160
192
224
256
5
Panels
6
Panels
160 192
180
200
216
240
240
280
320
288
336
384
Estimating
Estimating Gypsum Board Nails
Joist/Stud width
(on center)
Wallboard
Thickness
Gypsum Board
Nails
16”
24”
1/2”
5/8”
1 5 /
8
”
1 7 /
8
”
Approx. weight of nails per 1000 sq. ft.
of wallboard
5 1 /
4
” lbs.
5 1 /
4
” lbs.
Estimating Ready-Mix ™ Joint Compound and Tape
ToughRock ®
Wallboard
Sq. Ft.
Georgia-Pacific
Ready-Mix
Joint Compound
Estimated Amount of GP
Wallboard Tape
100–200 sq. ft.
500 sq. ft.
800 sq. ft.
12 lb. Pail
48 lb. Carton
61.7 lb. Pail two 60’ rolls one 250’ roll two 250’ rolls
Besides standard 4’ widths, ToughRock ® gypsum board is also available in a 54” width that eliminates the need for gap filler boards in horizontal applications when walls are 9’ high (see above illustration). Using 54” wide gypsum board when you have 9’ ceilings reduces the number of seams you’ll need to finish and cuts waste.
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
10 • For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com
ToughRock ® Gypsum Products
Installation
Ceilings
Apply gypsum boards to the ceiling before applying gypsum boards to the walls. Joists must not be spaced more than 24” (610 mm) o.c. For residential applications use 1/2” (12.7 mm)
ToughRock ® CD ® gypsum panels as a sag resistant alternative to 1/2” (12.7 mm) ToughRock gypsum panels. These panels are formulated to support spray textures paints and are able to support the same amount of insulation weight as 5/8” (15.9 mm) ToughRock ® Fireguard gypsum boards. Joists spaced 24” (610 mm) should only receive 1/2” (12.7 mm) ToughRock ®
CD ® gypsum boards or 5/8” (15.9 mm) ToughRock Fireguard gypsum boards. The boards may be applied either parallel or perpendicular to the ceiling framing. The maximum insulation load should not be more than 2.2 lbs/sf (10.7 kg/m2 ). Space nails 7” (178 mm), screws should be spaced 12” (305 mm) o.c. Please refer to the framing spacing requirements on page 9.
Improper framing construction and alignment can cause problems to telegraph through the boards. Excessive moisture or insulation weight can cause the ceiling boards to sag or cause problems with the joint treatment system.
Walls
Several methods are used to attach gypsum boards to the framing members, depending on the type of framing. Nailing is the conventional attachment method for wood stud walls.
Double nailing helps to minimize defects that are a result from loose attachment of the gypsum board. The use of screws helps to minimize loose board problems in wood framing and is required for steel stud framing.
Gypsum wallboard may also be attached by using adhesive. Use a caulking gun to put a 3/8”
(10 mm) bead of gypsum board adhesive on the wall studs before installing the board. Then nail the board around the edges, 8” (203 mm) o.c. and along the ends. This improves bond strength and reduces the number of fasteners needed.
Gypsum board may be hung perpendicular or parallel to the framing members. If horizontal, start at the top of the wall and attach the top boards first and work down the wall. Perpendicular orientation is often preferred because it generally reduces the number of joints that need to be finished. Fire-rated partitions may require parallel application.
Please refer to the specific rated assembly for details.
Masonry
Although it is permissible to apply gypsum boards directly to masonry walls, it is recommended that the wall be framed with studs or furring strips, either 16” (406 mm) or
24” (610 mm) o.c. The furring strips can either be 1” (25 mm) x 2” (51 mm) or 2’ (51 mm) x
2” (51 mm). Furring strips are necessary if the wall is to be insulated. Rigid foam is typically used to insulate the cavity. Gypsum wall boards would then be applied as described in the wall section above.
Corner Bead
Metal or paper corner beads provide strong, durable protection for outside angle corners, uncased openings, beams and soffits. The exposed portion of the bead resists impact and forms a surface to finish. Bead should be installed in one piece. Corner beads, depending on the type, may be nailed, crimped or embedded in place with drywall joint compound.
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 11
ToughRock ® Gypsum Products
Finishing Gypsum Board
Joints
The quality of framing and gypsum board application helps determine the finished appearance of drywall. The joints need to be finished to meet the desired visual appearance expectation. Please refer to the Levels of Gypsum Board Finish on page 13.
Gypsum Association publication, GA-214 Recommended Levels of Finish provides greater detail and explanation. Also, visit www.dwfc.org for further information about joints and finishing gypsum boards.
Bedding
No fasteners should protrude above the surface of the gypsum board. Apply a smooth, full, even coat of Ready-Mix Joint Compound into the recess created by the tapered edges of adjoining boards with a joint finishing knife. Center a strip of wallboard tape over the joint, and press it firmly into the wet bedding compound with a wallboard knife at a 45° angle.
Press hard enough to squeeze excess compound out from the edge of the tape, but leave enough compound for a good bond. Pull the wallboard knife back over the tape, drawing the excess compound back over the surface of the tape. The top of the tape should be covered with a thin layer of compound. Let dry about 24 hours.
Taping and Finishing
When the bedding coat is dry, use a 10” (254 mm) joint finishing knife to apply the second finish coat of Ready-Mix Joint Compound. Feather the edges and let dry about 24 hours. Then apply a final finish coat with a 12”
(305 mm) joint finishing knife. Extend this coat 2” (51 mm) wider than the first finish coat. Wait 24 hours, and sand lightly with a medium grit sandpaper. Avoid sanding down to the tape. Care should be taken to avoid sanding or scratching the face paper of the wallboard. Remove joint compound dust prior to decoration.
Fastener Heads
Drive fasteners at least 3/8” (10 mm) from the edge and end of the boards. Fastener should be driven perpendicular to the face of the gypsum board. Seat nails in a shallow dimple left by the hammer head. Do not crush the gypsum core or break the paper.
Drywall screws should applied with an electric screw gun and an adjustable screw-depth control head and a Phillips head bit.
The screw head should be driven slightly below the face of the gypsum boards. Care should be taken to avoid breaking the face paper. For proper nail and screw spacing requirements, please refer to the Maximum Framing Spacing chart on page 9.
Butt Joints
Butt joints (square cut edge joints) are finished in a similar manner as regular joints. Because butt joints are not tapered, care is needed to not allow the joint compound and tape to build up any more than necessary. To reduce the effect of the build-up, feather the edges of the finish coat to a width twice that of a tapered edge joint.
Outside Corner
Be sure the metal or paper cornerbead is attached firmly. Use a 5” (127 mm) joint finishing knife to spread Ready-Mix Joint
Compound about 3” (76 mm) or 4” (102 mm) past the metal or paper corner. Be sure to cover the edges. Let dry 24 hours. Apply second coat with a 10” (254 mm) knife. Feather edges 2” (51 mm) or 3” (76 mm) beyond first coat. Sand lightly when dry. A third coat may be needed.
Inside Corner
Cut a strip of wallboard tape the length of the corner to be finished. Crease the tape down the center. Use a 5” (127 mm) joint finishing knife to spread Ready-Mix Joint Compound about
2” (51 mm) on both sides of the corner. With the knife press the tape into the corner. Use enough pressure to squeeze some compound from the edge of the tape, leaving enough compound to form a good bond. Feather the compound 2” (51 mm) from the edge of the tape.
Let dry 24 hours, finishing only one side at a time. Let dry, finish other side of corner. Let dry, then sand. Be careful not to let the compound build up in the corner of the tape. Excess compound in the corner could cause hairline cracks.
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
12 • For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com
ToughRock ® Gypsum Products
Levels of Gypsum Board Finish
Level Joints Interior Angles Accessories Fasteners Surface
#0 No taping, fi nishing or accessories required.
This level of fi nish may be useful in temporary construction or whenever the fi nal decoration has not been determined.
#1 Tape set in joint compound.
Tape set in joint compound.
Tool marks and ridges acceptable. Surface free of excess joint compound.
Frequently specifi ed in plenum areas above ceilings, in attics, in areas where the assembly would generally be concealed, or in building service corridors and other areas not normally open to public view. Accessories optional at specifi er discretion in corridors and other areas with pedestrian traffi c. Some degree of sound and smoke control is provided; in some geographic areas, this level is referred to as “fi re-taping.” Where a fi re-resistance rating is required for the gypsum-board assembly, details of construction shall be in accordance with reports of fi re tests of assemblies that have met the fi re-rating requirement. Tape and fastener heads need not be covered with joint compound.
#2 Tape embedded in joint compound and wiped with a joint knife, leaving a thin coat of compound over tape.
Tape embedded in joint compound and wiped with a joint knife, leaving a thin coat of compound over tape.
Shall be covered by one separate coat of joint compound.
Shall be covered by one separate coat of joint compound.
Surface shall be free of excess joint compound.
Tool marks and ridges acceptable. Joint compound applied over the body of the tape at the time of tape embedment shall be considered a separate coat of joint compound and shall satisfy the conditions of this level.
Specifi ed where gypsum board is used as a substrate for tile. May also be specifi ed in garages, warehouse storage or other similar areas where surface appearance is not of primary concern.
#3 Taped as in level #2, then covered with one separate coat of joint compound.
Taped as in level #2, then covered with one separate coat of joint compound.
Shall be covered by two separate coats of joint compound.
Shall be covered by two separate coats of joint compound.
Joint compound shall be smooth and free of tool marks and ridges.
Note: It is recommended that the prepared surface be coated with a drywall primer prior to the application of final finishes. See architect’s painting and wallcovering specifications.
Typically specifi ed in appearance areas which are to receive heavy- or medium-texture (spray or hand-applied) fi nishes before wall painting, or where heavy-grade wallcoverings are to be applied as the fi nal decoration. This level of fi nish is not recommended where smooth painted surfaces, or light- to medium-weight wallcoverings are specifi ed.
#4 Taped as in level #2, then covered with two separate coats of joint compound.
Taped as in level #2, then covered with one separate coat of joint compound.
Shall be covered by three separate coats of joint compound.
Shall be covered by three separate coats of joint compound.
Joint compound shall be smooth and free of tool marks and ridges.
Note: It is recommended that the prepared surface be coated with a drywall primer prior to the application of final finishes. See architect’s painting and wallcovering specifications.
This level should be specifi ed where fl at paints, light textures, or wallcoverings are to be applied. In critical lighting areas, fl at paints applied over light textures tend to reduce joint photographing. Gloss, semi-gloss and enamel paints are not recommended over this level of fi nish. The weight, texture and sheen level of wallcoverings applied over this level of fi nish should be carefully evaluated. Joints and fasteners must be adequately concealed if the wallcovering material is lightweight, contains limited pattern, has a gloss fi nish or any combination of these features is present. Unbacked vinyl wallcoverings are not recommended over this level of fi nish.
#5 Taped as in level #2, then covered with two separate coats of joint compound.
Taped as in level #2, then covered with one separate coat of joint compound.
Shall be covered by three separate coats of joint compound.
Shall be covered by three separate coats of joint compound.
A thin skin of joint compound, or a material manufactured especially for this purpose, shall be applied to the entire surface. The surface shall be smooth and free of tool marks and ridges.
Note: It is recommended that the prepared surface be coated with a drywall primer prior to the application of final finishes. See architect’s painting specifications.
This level of fi nish is highly recommended where gloss, semi-gloss, enamel or non-textured fl at paints are specifi ed, or where severe lighting conditions occur. This highest-quality fi nish is the most effective method to provide a uniform surface and minimize the possibility of joint photographing or fasteners showing through the fi nal decoration.
Source: GA-214 Recommended Levels of Gypsum Board Finish.
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 13
ToughRock ® Gypsum Products
Recommendations and Limitations for Use
The following recommendations and limitations are important to ensure the proper use and benefits of ToughRock ® gypsum board, ToughRock ® joint treatment systems and ToughRock ® textures and plaster. Failure to strictly adhere to such recommendations and limitations may void the limited warranty provided by Georgia-Pacific Gypsum for such product.
For additional details, please go to www.gpgypsum.com and select ToughRock gypsum board, ToughRock joint treatment systems or ToughRock textures and plaster for warranty information.
ToughRock Gypsum Board
1. Exposure to excessive or continuous moisture and extreme temperatures should be avoided. Gypsum board is not recommended in solar heating systems where board will be in contact with surfaces exceeding 125°F (52°C).
2. Must be adequately protected against wetting when used as a base for ceramic wall tile (use DensShield ® Tile Backer for this purpose.)
3. Maximum spacing of framing members: 1/2” (12.7 mm) and 5/8” (15.9 mm) gypsum boards are designed for use on framing centers up to 24” (610 mm); 1/4” (6.4 mm) and 3/8” (9.5 mm) boards on centers up to 16” (406 mm) (but neither is intended for single layer application). In both walls and ceilings when 1/2” (12.7mm) or 5/8” (15.9 mm) gypsum boards are applied across framing on 24” (610 mm) centers and joints reinforced, blocking is not required. Neither 3/8” (9.5 mm) nor 1/4”
(6.4 mm) ToughRock Gypsum Boards are recommended for use on steel framing as base for water-based texturing materials.
When a water-based texture is used on ceilings with framing 24” (610 mm) o.c., 5/8” (15.9 mm) ToughRock ® Fireguard ® gypsum boards, 1/2” ToughRock ® Fireguard C ™ gypsum boards or 1/2” (12.7 mm) ToughRock ® CD ® Ceiling Boards should be used to prevent sag.
4. The application of gypsum panels over an insulating blanket that has first been installed continuously across the face of the framing members is not recommended. Blankets should be recessed and the blanket flanges attached to sides of studs or joists.
5. To prevent objectionable sag in new gypsum board ceilings, the weight of the overlaid unsupported insulation should not exceed
1.3 psf (6.3 kg/m 2 ) for 1/2” (12.7 mm) thick gypsum boards with frame spacing 24” (610 mm) o.c.; 2.2 psf (10.7 kg/m 2 ) for 1/2”
(12.7 mm) gypsum boards on 16” (406 mm) o.c. framing or 1/2” (12.7 mm) ToughRock CD Ceiling Boards on 24” (610 mm) framing and 5/8” (15.9 mm) gypsum boards 24” (15.9 mm) o.c.; 3/8” (9.5 mm) thick gypsum boards must not be overlaid with unsupported insulation. A vapor retarder should be installed in exterior ceilings and the plenum or attic space should be properly vented.
During periods of cold or damp weather when an independent vapor retarder is installed on ceilings behind the gypsum board, it is important to install the ceiling insulation before or immediately after installing the ceiling board. Failure to follow this procedure may result in moisture condensation on the back side of the gypsum board, causing the board to sag.
Water-based textures, interior finishing materials and high ambient humidity conditions can produce sag in gypsum ceiling panels if adequate vapor and moisture control is not provided. The following precautions must be observed to minimize sagging of ceiling panels:
a) Where vapor retarder is required in cold weather conditions, the temperature of the gypsum ceiling panels and vapor retarder must remain above the interior air dew point temperature during and after the installation of panels and finishing materials.
b) The interior space must be adequately ventilated and air circulation must be provided to remove water vapor from the structure. Most sag problems are caused by the condensation of water within the gypsum panel. The placement of vapor retarders, insulation levels and ventilation requirements will vary by location and climate and should be reviewed by a qualified engineer if in question.
6. To produce final intended results, certain recommendations regarding surface preparation, painting products and systems must be adhered to for satisfactory performance.
7. Precautions should be taken against creating a double vapor retarder by using gypsum panels as a base for highly water vapor resistant coverings when the wall already contains a vapor retarder. Moreover, do not create a vapor retarder by such wall coverings on the interior side of exterior walls of air-conditioned buildings in hot humid climates where conditions dictate a vapor retarder location near the exterior side of the wall. Such conditions require assessment by a qualified mechanical engineer.
HANDLING AND USE – CAUTION: This product may contain fiberglass which may cause skin irritation. Dust and fibers produced during the handling and installation of the product may cause skin, eye and respiratory tract irritation. Avoid breathing dust and minimize contact with skin and eyes. Wear long sleeve shirts, long pants and eye protection. Always maintain adequate
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
14 • For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com
ToughRock ® Gypsum Products ventilation. Use a dust mask or NIOSH/MSHA approved respirator as appropriate in dusty or poorly ventilated areas.
For additional product fire, safety and use information go to www.gp.com/safetyinfo or call 1-800-225-6119.
Joint Treatment
8. Georgia-Pacific Gypsum joint compounds should not be intermixed with any other compounds.
9. For interior use only—except ToughRock ® Setting Joint Compound, which may be used for treating joints of DensGlass ®
Sheathing panels in exterior soffit applications.
10. Protect bagged and boxed products against wetting; protect ready-mixed products from freezing and extreme heat.
11. Each compound coat must be dry before the next is applied—except ToughRock ® Setting and ToughRock ® Sandable Setting
Compound—and completed joint treatment must be thoroughly dry before decorating.
12. Prior to using any epoxy coating over any surface treated with joint compound, consult the epoxy coating manufacturer and follow manufacturer’s specific recommendations regarding the preparation or suitability of substrates for the epoxy coating.
Many epoxy coatings exert significant shear stress on the substrate as the strong epoxy film shrinks while curing/drying. This stress can cause the bond of the joint compound to fail, resulting in delamination problems.
HANDLING AND USE – WARNING! Heat develops as the product hardens (rehydrates) and may cause serious burns resulting in possible permanent injury. After mixing with water, do not allow prolonged contact with skin until the product has completely hardened and cooled.
Mixing or sanding this product after drying may generate dust which can irritate eyes, nose, throat, skin and upper respiratory tract. Use wet sanding to minimize dust generation and always maintain proper ventilation in the work area. Avoid breathing dust and minimize contact with skin and eyes. Wear long sleeve shirts, long pants and eye protection. Use a dust mask or
NIOSH/MSHA approved respiratory protection during mixing dry materials, while sanding and during clean-up as appropriate.
For Material Safety Data Sheet or additional information, call 1-800-225-6119 or go to www.gpgypsum.com.
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo.
For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.com • 15
High-Performance Gypsum Products from Georgia-Pacific
DensDeck ® Roof Boards Fiberglass mat roof board used as the ideal thermal barrier and cover board to improve resistance to wind uplift, hail, foot traffic, fire and mold in a broad range of commercial roofing applications. Look for DensDeck Prime and DensDeck DuraGuard, too.
DensGlass
®
Sheathing The original and universal standard of exterior gypsum sheathing offers superior weather resistance, with a 12-month weather exposure limited warranty. Look for the familiar GOLD color.
DensGlass
®
Shaftliner Specially-designed panels for moisture-prone vertical or horizontal shafts, interior stairwells and area separation wall assemblies.
12-month weather exposure limited warranty. GREENGUARD listed for microbial resistance.
DensArmor Plus ®
High-Performance
Interior Panel
DensArmor Plus
Abuse-Resistant
Interior Panel
DensArmor Plus
®
®
Impact-Resistant
Interior Panel
High-performance interior panel accelerates scheduling because it can be installed before the building is dried-in. 12-month weather exposure limited warranty. GREENGUARD Indoor Air Quality Certified, ® GREENGUARD Children & Schools SM Certified.
GREENGUARD listed for microbial resistance. Listed in CHPS ® High Performance Product Database as a low emitting product.
Same benefits as DensArmor Plus ® High-Performance Interior Panel with added resistance to scuffs, abrasions and surface indentations. Ideal for healthcare facilities and schools. GREENGUARD Indoor Air Quality Certified, ® GREENGUARD Children &
Schools SM Certified. GREENGUARD listed for microbial resistance. Listed in CHPS ® High Performance Product Database as a low emitting product.
Even greater durability with an embedded impact-resistant mesh for the ultimate resistance in high traffic areas. Ideal for healthcare facilities, schools and correctional institutions. GREENGUARD Indoor Air Quality Certified, ® GREENGUARD Children &
Schools SM Certified. GREENGUARD listed for microbial resistance. Listed in CHPS ® High Performance Product Database as a low emitting product.
DensShield ® Tile Backer Acrylic-coated tile backer stops moisture at the surface. Lightweight and strong, built for speed on the job site. Conforms to requirements of IBC/IRC Code. GREENGUARD listed for microbial resistance.
ToughRock ®
Gypsum Boards
Paper-faced line of gypsum panels for a variety of applications including interior wall and ceiling applications, abuse-resistant boards, veneer plaster base systems, and panels for use in fire-rated assemblies. Listed in CHPS ® High Performance Product Database as a low emitting product. Use Mold-Guard TM treated paper gypsum boards for enhanced mold resistance.
U.S.A.
Georgia-Pacific Gypsum LLC
CANADA Georgia-Pacific Canada LP
SALES INFORMATION AND ORDER PLACEMENT
U.S.A.
Midwest: 1-800-876-4746 West: 1-800-824-7503
South: 1-800-327-2344 Northeast: 1-800-947-4497
CANADA Canada Toll Free: 1-800-387-6823
Quebec Toll Free: 1-800-361-0486
TECHNICAL HOTLINE U.S.A. and Canada: 1-800-225-6119
Some of our products have been certified by Scientific Certification
Systems (SCS). SCS is an internationally recognized third-party evaluation, testing and certification organization. Its program spans a wide cross-section of the economy, including manufacturing and retailing, consumer products, the energy industry, and the home improvement and construction sectors. For details on specific
Georgia-Pacific Gypsum products and plants, please contact our
Technical Hotline at 800-225-6119.
TRADEMARKS –
Unless otherwise noted, all trademarks are owned by or licensed to Georgia-
Pacifi c Gypsum LLC. The
GREENGUARD INDOOR AIR
QUALITY CERTIFIED Mark and the GREENGUARD Children &
Schools Mark are registered certifi cation marks used under license through the
GREENGUARD Environmental
Institute. LEED, USGBC and related logo are trademarks owned by the U.S. Green
Building Council and are used by permission. Collaborative for High Performance Schools and CHPS are trademarks owned by Collaborative for
High Performance Schools Inc.
MICROSOFT is a registered trademark of Microsoft
Corporation. MASTERSPEC is a registered trademark of The
American Institute of
Architects. REVIT is a registered trademark of
AutoDesk, Inc.
WARRANTIES, REMEDIES
AND TERMS OF SALE –
For current warranty information for this product, please go to www.gpgypsum.com and select the product for warranty information.
All sales of this product by
Georgia-Pacifi c are subject to our Terms of Sale available at www.gpgypsum.com.
UPDATES AND CURRENT
INFORMATION –
The information in this document may change without notice. Visit our website at www.gpgypsum.com for updates and current information.
CAUTION: For product fire, safety and use information, go to gp.com/safetyinfo or call 1-800-225-6119.
FIRE SAFETY CAUTION –
Passing a fi re test in a controlled laboratory setting and/or certifying or labeling a product as having a one-hour, two-hour, or any other fi re resistance or protection rating and, therefore, as acceptable for use in certain fi re rated assemblies/systems, does not mean that either a particular assembly/system incorporating the product, or any given piece of the product itself, will necessarily provide one-hour fi re resistance, two-hour fi re resistance, or any other specifi ed fi re resistance or protection in an actual fi re.
In the event of an actual fi re, you should immediately take any and all actions necessary for your safety and the safety of others without regard for any fi re rating of any product or assembly/system.
www.gpgypsum.com
©2011 Georgia-Pacific Gypsum LLC. All rights reserved. Printed in the U.S.A. GEO 5/11. GP Lit. Item #622604.