All Power APGG12000GL Dual Fuel 12000-Watt Gasoline/Propane Portable Generator Operating Guide
All Power APGG12000GL is a dual-fuel generator that can run on either gasoline or propane, providing a versatile power source for various applications. With a maximum output of 12,000 watts on gasoline and 9,000 watts on propane, it delivers ample power for demanding tasks like running appliances, tools, or lights during power outages or outdoor activities. Its 8-gallon fuel tank allows for extended operation, while the electric start feature ensures easy ignition.
Advertisement
Advertisement
APGG12000GL
DUAL-FUEL GENERATOR
12000 WATT GASOLINE / 9000 WATT PROPANE
Please read and save these instructions.
www.jdna.com
12000W Dual-Fuel Generator
Topi c
YtnarraWdetimiL
Limitations and Exclusions
Senilediu GytefaS
Snoituacer PlareneG
Battery
Assembly
Operation
Spark Plug Service
Inspection, Cleaning, Maintenance and Storage
Installation
Speci fications
GnitsiLstra PlareneG
Page
16
17
18
3
5
6
7
25
26
32
34
53 altitude kit
2 altitude kit
12000W
Dual-Fuel Generator
JD North America warrants to the original purchaser who uses the product in a consumer application (personal, residential or household usage) that all products covered under this warranty are free from defects in material and workmanship for 2 years or 300 hours whichever comes first (1-year parts and labor and following 1 year parts only) from the date of purchase.
All products covered by this limited warranty which are used in commercial applications
(i.e. income producing) are warranted to be free of defects in material and workmanship for 90 days from the date of original purchase. Products covered under this warranty include air compressors, air tools, service parts, pressure washers and generators.
An individual or entity that purchases the product from whatever source with the intent to resell the product is an unauthorized reseller ("unauthorized dealer").
Please note this Limited Warranty does not apply to floor models or "demos" (except as specifically provided herein) or to products sold by unauthorized dealers, including without limitation, unauthorized resellers on third party websites, including, without limitation, Craigslist, eBay, Amazon, etc.
Unauthorized dealers are not "original purchasers" for the purpose of this Limited Warranty.
If purchaser is not the original purchaser of this product, purchaser takes the product "AS IS,"
"with all faults" and without warranty. If the purchase of this product was not directly from JDNA, proof of purchase will be required to demonstrate that purchaser is the original purchaser and the product was purchased from an authorized dealer, and eligible to make a valid claim under this limited warrant y.
JD North America JD North America
JD North America
Purchaser JD North America
Service
12000W
Dual-Fuel Generator
JD North America
JD North America
4
12000W
Dual-Fuel Generator
Limitations and exclusions
This Limited Warranty shall not apply to:
1. Bent or broken crankshaft or resultant damage caused by vibration related to a bent or broken crankshaft. Also, damage caused by loose engine mounting bolts or improper or imbalanced accessories or blades mounted to the crankshaft.
2. Repairs required because of prolonged storage including damage caused by old or contaminated fuel in the fuel tank, fuel lines or carburetor, sticky valves or corrosion and rust of engine parts.
3. Repair required due to overheating. (Most often caused by overloaded or clogged or damaged or missing flywheel, fan, inlet air passages, cooling
fans or air shrouds.)
4. Dirt or grit related wear caused by improper air cleaner mai ntenance (most often resulting in worn piston, piston rings, cylinders, valves, valve
guides, carburetor or other internal components).
5. Broken or scored parts caused by low oil level, dirty or imp roper grade of oil.
6. Engine tune-ups and normal maintenance service including, but not limited to, valve adjustment,normal replacement of service items, fuel and lubricating oil, etc.
7. Any engine which has been subject to negligence, misuse, acc ident, mis-application or over-speeding.
8. Any engine that has been installed, repaired, or altered by anyone in a manner which in JDNA’s sole judgment adversely affects its performance
or reliability.
9. Any engine which has been fitted with or repaired with parts or components not manufactured or approved by JDNA which in JDNA’s sole judgment
adversely affects its performance or reliability.
10. Instances when normal use has exhausted the life of a compo nent or an engine, including but not limited to using as a sole source of power.
5
Owner’s Manual
Safety Guidelines - Definitions
This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREVENT
EQUIPMENT PROBLEMS. The following symbols help you recognize this information. Please read the manual and pay attention to these sections.
Save These Important Safety Instructions!
Read and understand all of these safety instructions. Be sure to retain them f or future use.
WARNING! WARNINGS INDICATE A CERTAINTY OR STRONG
POSSIBILITY OF PERSONAL INJURY OR DEATH IF
INSTRUCTIONS ARE NOT FOLLOWED.
CAUTION: CAUTIONS INDICATE A POSSIBILITY OF
EQUIPM ENT DAM AGE IF INSTRUCTIONS ARE NOT
FOLLOWED.
NOTE: NOTES GIVE HELPFUL INFORM ATION
WARNING! IM PROPER OPERATION OR M AINTENANCE
OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY
AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL
WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING
THIS EQUIPM ENT. WHEN USING AIR TOOLS, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE
THE RISK OF PERSONAL INJURY.
6
12000W
Dual-Fuel Generator
General Precautions
WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN
SEVERE IN JURY OR DEATH.
CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN ALSO
RESULT IN DAMAGE TO THE TOOL AND/OR THE ITEM YOU ARE WORKING
ON.
DANGER
CARBON MONOXIDE
Using a generator indoors WILL KILL YOU IN MINUTES.
Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust, you are breathing CO. But even If you cannot smell the exhaust, you could be breathing CO.
• Never use a generator inside your home, basement, or garage or less than 20 feet from any window, door, or vent.
• When using a generator, use a battery-powered or battery backup CO detector in your home.
Even when you use a generator correctly, CO may leak into the home.
If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air
RIGHT AWAY. See a doctor. You could have carbon monoxide poisoning.
WARNING! THE EXHAUST CONTAINS POISONOUS CARBON MONOXIDE
GAS THAT CAN CAUSE LOSS OF CONSCIOUSNESS AND MAY LEAD TO
DEATH.
Fuel and Oil
This product requires oil and fuel. Attempting to start the engine without oil will ruin the engine and void the warranty. Work in well ventilated area. Keep cigarettes, flames or sparks away from the work area or where gasoline is stored.
WARNING! GASOLINE AND PROPANE ARE EXTREMELY FLAMMABLE AND
ARE EXPLOSIVE UNDER CERTAIN CONDITIONS.
KEEP OUT OF REACH OF CHILDREN.
• Gasoline and propane fuel and fumes are flammable and potentially explosive. Use proper fuel storage and handling procedures. Always have multiple ABC class fire extinguishers nearby.
• Keep the generator and surrounding area clean at all times.
7
Owner’s Manual
• Gasoline or oil spills must be cleaned up immediately. Dispo se of fluids and cleaning materials as per any local, state,or federal codes and regulations. Store oily rags in a covered metal container. If Propane is leaking, the valve must be closed immediately. Check for leaks and deal with them immediately.
• Never store fuel or other flammable materials near the generator.
General Precautions (cont’d)
Fuel and Oil (cont’d)
• Do not smoke or allow sparks, flames or other sources of ignition around the engine and fuel tank. Fuel vapors are explosive.
• Keep grounded conductive objects, such as tools, away from exposed, live electrical parts and connections to avoid sparking or arcing. These events could ignite fumes or vapors.
• Do not refill the fuel tank or replace the propane cylinder while the engine is running or while the engine is still hot. Do not operate the generator with known leaks in the fuel system
• Excessive buildup of unburned fuel gases in the exhaust system can create a potentially
explosive condition. This buildup can occur after repeated failed start attempts, valve testing, or hot engine shutdown. If this occurs, open exhaust system drain plugs, if equipped, and allow the gases to dissipate before attempting to restart the generator.
• Use only engine manufacturer recommended fuel and oil.
Fuel:
Fuel capacity is 8 gallons(30 L). Use regular unleaded gasoline with a minium octane rating of 90.
Use only an approved propane cylinder equipped and supplied inlet pipe with LPG regulator.
Oil:
Oil capacity is 1.16 qt (1.1 L)
Please change oil types on weather conditions.
Hot Components
WARNING! ENGINE AND EXHAUST SYSTEM PARTS BECOME VERY
HOT AND REMAIN HOT FOR SOME TIME AFTER THE ENGINE IS RUN. WEAR
INSULATED GLOVES OR WAIT UNTIL THE ENGINE AND EXHAUST SYSTEM
HAVE COOLED BEFORE HANDLING THESE PARTS.
Power Output
This generator is not designed to power sensitive electronic equipment (including computers and medical devices) without the addition of an approved line conditioner, which is sold separately.
CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT
WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE
DAMAGE TO THE EQUIPMENT. JD NORTH AMERICA IS NOT RESPONSIBLE
FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN
APPROVED LINE CONDITIONER.
8
12000W
Dual-Fuel Generator
General Precautions (cont’d)
Work Area
• Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.
• Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes.
• Keep bystanders, children, and visitors away while operating a generator. Provide barriers or shields as needed.
Electrical Safety
• Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs.
• Grounding provides a low-resistance path to carry electricity away from the user in the event of an electrical malfunction.
• Double insulated tools are equipped with a polarized plug where one blade is wider than the other. This plug fits in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized outlet.
Do not change the plug in any way. Double insulation eliminates the need for the three-wire grounded power cord and grounded power supply system.
• Do not expose generator to rain or wet conditions. Water entering a generator will increase the risk of electric shock.
• Do not abuse the power cord. Keep power cords away from heat, oil, sharp edges, or moving parts. Replace damaged power cords immediately. Damaged power cords increase the risk of electric shock.
• When operating a power tool outside, use an outdoor extension cord marked “W-A” or “W”.
These extension cords are rated for outdoor use, and reduce the risk of electric shock.
9
Owner’s Manual
General Precautions (cont’d)
Electrical Safety (cont’d)
• All connections and conduits from the generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable.
• The generator must be earth-grounded for fixed installations in accordance with all relevant electrical codes and standards before operation.
• Do not attempt to connect or disconnect load connections while standing in water or on wet or soggy ground.
• Do not touch electrically energized parts of the generator and interconnecting cables or conductors with any part of the body or with any non-insulated conductive object.
• Connect the generator only to a load or electrical system (120 volt) that is compatible with the electrical characteristics and rated capacities of the generator.
• Before servicing equipment powered by the generator, disconnect the equipment from its power input.
• Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked, cut abraded or otherwise degraded. Replace terminals that are worn, discolored, or corroded.
Keep terminals clean and tight.
• Insulate all connections and disconnected wires.
• Guard against electric shock. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures.
Personal Safety
• Stay alert. Watch what you are doing, and use common sense when operating a generator. Do not use generator while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating generators may result in serious personal injury.
• Contain all hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry or long hair can be caught in moving parts.
10
12000W
Dual-Fuel Generator
General Precautions (cont’d)
Personal Safety (cont’d)
• Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect the spark plug wire when not in use.
• Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is left attached to a rotating part of the generator may result in personal injury.
• Do not overreach. Keep proper footing and balance at all times.
• Use safety equipment. Always wear eye protection. Wear ANSI approved safety impact eye goggles. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for appropriate conditions.
• Do not force the generator. Use the correct generator for your application. The correct generator will do the job better and safer at the rate for which it is designed.
• Do not use the generator if the power switch does not turn it on or off. Any generator that cannot be controlled with the power switch is dangerous and must be replaced.
Generator Use and Care
Make sure the power switch is in its “OFF” position and disconnect the spark plug wire before making any adjustment, changing accessories, or storing the generator. Such preventive safety measures reduce the risk of starting the generator accidentally.
Store idle generators out of reach of children and other untrained persons. Generators are dangerous in the hands of untrained users.
Maintain generators with care. Do not use damaged generator. Tag damaged generators “Do not use” until repaired.
Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the generator’s operation. If damaged, have the generator serviced before using. Many accidents are caused by poorly maintained generators.
Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one generator may become hazardous when used on another generator.
11
Owner’s Manual
General Precautions (cont’d)
Servicing
Maintain labels and name plates on the generator and engine. These carry important information.
If unreadable or missing, contact our service center toll free at 888-896-6881 immediately for a replacement.
Generator service must be performed only by a qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury.
When servicing a generator, use only identical replacement parts. Follow all appropriate instructions in this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury.
Heart Pacemakers
WARNING! PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR
PHYSICIAN(S) BEFORE USING THIS PRODUCT. ELECTROMAGNETIC
FIELDS IN CLOSE PROXIMITY TO A HEART PACEMAKER COULD CAUSE
INTERFERENCE TO OR FAILURE OF THE PACEMAKER.
Installation
• Ensure installation meets all applicable safety, and local and national electrical codes. Have installation performed by a qualified, licensed electrician and building contractor.
• All electrical work, including the earth-ground connection, should be completed by a licensed electrician.
• Any separate fuel storage or generator supply facility must be built or installed in full compliance with all relevant local, state, and federal regulations.
12
12000W
Dual-Fuel Generator
General Precautions (cont’d)
Installation (cont’d)
• If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It should not be run outdoors without protection to the generator and wiring conduit.
• The generator weighs 220 lbs (approx). Two or more people should assist when moving or lifting this product. Never lift the generator using the engine or alternator lifting lugs. Connect lifting equipment to the frame of the generator.
• Before lifting the generator, ensure the lift rigging and supporting structure are in good condition, and are rated to lift such a load.
• Keep all personnel away from the suspended generator during relocating process.
• The supporting floor/ground surface should be level and strong enough to safely hold the weight of the generator. If the floor/grounded surface is not level, strong cross members should be placed under the full length of the generator frame at its low side.
• For trailer installation, the generator should be mounted on the center point of the trailer, over the wheels. The trailer must be capable of supporting the weight of the generator and all contents (tools, etc.)
• Install sound-and weather-proofing only when it is not raining or snowing to avoid trapping moisture within the generator’s area.
Mechanical
• Always make sure the power switch is in its “OFF” position. Disconnect the spark plug wire, and allow the engine to completely cool before carrying out maintenance.
• Check for damaged parts. Before using the generator, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function.
Check for alignment and binding of moving parts, any broken parts or mounting fixtures, and any other condition that may affect proper operation.
• The generator is designed with guards for protection from moving parts. In any case, care must still be taken to protect personnel and equipment from other mechanical hazards when working around the generator.
13
Owner’s Manual
General Precautions (cont’d)
Mechanical (cont’d)
• Do not operate the generator with safety guards removed. While the generator is running, do not attempt to reach around the safety guard for maintenance or any other reason.
• Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts. Be aware that when engine parts are moving fast they cannot be seen clearly.
• Keep access doors on enclosures closed and locked when access is not required.
• When working on or around the generator always wear protective clothing including ANSI approved safety gloves, safety eye goggles, and safety hat.
• Do not alter or adjust any part of the generator that is assembled and supplied by the manufacturer.
• Always follow and complete scheduled engine and generator maintenance.
Chemicals
• Avoid contact with hot fuel, oil, exhaust fumes, and hot solid surfaces.
• Avoid body contact with fuels, oils, and lubricants used in the generator. If swallowed, seek medical treatment immediately. Do not induce vomiting if fuel is swallowed. For skin contact, immediately wash with soap and water. For eye contact, immediately flush eyes with clean water and seek medical attention.
Noise
• Prolonged exposure to noise levels above 68 DBA is hazardous to hearing. Always wear ANSI approved ear protection when operating or working around the generator when it is running.
14
12000W
Dual-Fuel Generator
General Precautions (cont’d)
Extension Cord
If an extension cord (not included) is used, make sure to use only UL approved cords having the correct gauge and length according to the following table:
Nameplate Amps (@ full load) Cord Lengths
0 ft.- 50 ft. 50 ft.-100 ft. 100 ft.-150 ft. 150 ft.-200 ft.
0 - 5
5.1 - 8
16
16
AWG
AWG
16
14
AWG
AWG
12
10
AWG
AWG
12
-
AWG
8.1 - 12
12.1 - 15
15 - 20
14 AWG
12 AWG
10 AWG
12
10
10
AWG
AWG
AWG
-
-
-
-
-
-
15
Owner’s Manual
Battery
To start generator electrically you will need have the battery installed correctly.
This requires a 12v 18ah lawn tractor battery with the following dimensions: The dimensions are Wx7.5” Dx5” Hx7” (including terminals).
A rated cranking amperage of 200. Terminals are regular, not reversed.
Photos below demonstrate battery plate attachment.
16
12000W
Dual-Fuel Generator
Assembly
Unpacking
1. Remove the generator and loose parts box from the carton.
2. Compare the accessory with the inventory list below.
Loose Parts (Wheel kit and handle)
Check all loose parts against the following list. Contact your dealer toll free at 888.896.6881 if any of the loose parts shown are not included with your generator
Hardware Check:
Your Hardware Kit should include:
1)
2)
3)
4)
Two Handles with bolts, nuts, pin with chain and brackets
One axle shaft with bolts and nuts
Four washers
Two cotter pins
5)
6)
One generator leg with bolts and nuts
Two wheels
4
1
3
6 5
2
17
Owner's Manual
Operation
�
&
NOTE: THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE
CONTROLS MENTIONED BELOW.
CAUTION: PRIOR TO FIRST USING THE GENERATOR, THE ENGINE MUST BE
FILLED WITH OIL OF A HIGH QUALITY SAE 10W-30 GRADE ENGINE OIL.
TO DO SO, UNSCREW AND REMOVE THE ENGINE'S OIL DIPSTICK LOCATED
AT THE BOTTOM OF THE ENGINE CRANKCASE. FILL THE ENGINE'S
CRANKCASE UNTIL THE OIL LEVEL IS LEVEL WITH THE UPPER MARKED
LINE ON THE DIPSTICK. THEN SCREW THE DIPSTICK BACK INTO
THE OIL FILL HOLE.
Before Starting the Gener��or
1. Check that the engine key switch 1s in its
"RUN" position.
2. Before the first use, remove the fuel tank cap and fill the fuel tank with unleaded gasoline.
When fueling, be sure that the fuel strainer is in place. Check the fuel amount
「 eached the fuel level in the fuel tank and has not exceeded the maximum amount. Replace the fuel tank cap.
_
三
言
L
。三:
E
We recommend unleaded gasoline high octane non-ethanol, Because it produces fewer engine and spark plug deposits and extends exhaust system I ife.
Never use stale or contaminated gasoline or LPG of inferior propane composition. Avoid getting dirt or water in the fuel tank.
Fuel tank capacity:30L(8 gallons)
18
12000W
Dual-Fuel Generator
Gasoline Starting.
1
、
Move the GAS-LPG switch clockwise to the vertical position.
2
Disconnect any electric devices.
3
、 ut the key switch on the “RUN” positi on.
The engine switch enables and disables the ignition system.
STOP: To stop the engine
RUN: To run the engine
START: To Start the engine
4. Turn the fuel valve clockwise to the “ON” position.
5. To start a cold engine, move the choke lever to th e
CLOSED position. To restart a warm engine, leave the choke lever in the OPEN position.
The choke lever opens and clo ses the choke valve in the carburetor.
The CLOSED position enriches the fuel mixture from starting a cold engine .
The OPEN position provides the correct fuel mixture for operation after starting, and fo r restarting a warm engine.
19
6. To o perate the Recoil Start :
Pull the starter grip lightly until you feel resistance, then pull briskly. Return the starter grip gently.
Pulling the starter grip ope rates the recoil sta rt t o crank the engine
To operate the Electric start:
Push and hold the engine switch on the “START” position for 3~5s and crank the engine.
Holding this position longer can damage the starter solenoid and void its warranty.
Owner’s Manual
Starter Grip
7. If the choke has been moved to the “OPEN ” position
to start the engine, gradually move it to the “CLOSE”
position as the engine warms up.
8. Push the circuit breakers to “ON” position.
Propane Starting
1. Move the GAS-LPG switch counter
-clockwise to the horizontal position.
2. Attach the LPG Supply hose to the LPG cylinder and the other end to the inlet connector .
20
12000W
Dual-Fuel Generator
3.
Fully open the LPG cylinder fuel knob.
4. Put the circuit breaker to “OFF” position.
Disconnect any electric devices.
5.
Move the choke lever to the “CLOSE” position. For restarting a warm engine, move the choke lever to the “OPEN” position.
6.
KEY START: Turn the key to the “START” position.
When engine starts, release the key back to the
“RUN” position.
,
RECOIL START: Turn the key to the “RUN” position, pull the recoil starter slowly until resistance is felt and then pull rapidly to start engine.
21
Starter Grip
Owner’s Manual
7. Move the choke lever to the “OPEN” position.
8. Push the circuit breakers to the “ON” position.
Note: If you need to alternate fuel, you can change-over directly the GAS-LPG fuel
Stopping Engin e
1. Put the circuit breaker to “OFF” position.
2. Turn the engine switc h to the “STOP” position .
STOP
3. Turn the fuel valve lever to the “ OFF” positio n.
When the engine is not in use, leave the fuel valve in
the “O FF” position to prevent to reduce the possibility of fuel leakage.
4. Shut down the LPG cylinder fuel knob.
22
12000W
Dual-Fuel Generator
Operation (cont’d)
Powering 120 Volt AC Tools And Equipment:
1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity (120 V AC @ 66.7 AMPs) is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator.
CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT
WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE
DAMAGE TO THE EQUIPMENT. ALL-POWER IS NOT RESPONSIBLE FOR
ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN
APPROVED LINE CONDITIONER.
2. Once the generator is running, simply connect the power cords of 120 volt AC powered tools and equipment into the 120 volt AC dual outlets.
NOTE: THE GENERATOR FEATURES AN AC NON-FUSE THERMAL PROTECTOR
TO PROTECT THE AC CIRCUIT IN CASE OF AN OVERLOAD. SHOULD
AN OVERLOAD OCCUR, THE BREAKER WILL POP.
3. Disconnect all electrical powered tools and equipment from the generator’s 120 volt AC dual outlets.
4. After the engine and generator have completely cooled, store generator in a safe, clean, dry location (if not already installed).
23
Owner’s Manual
Operation (cont’d)
Powering 12 Volt DC tools and Equipment:
1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity (12V DC) is adequate to supply all electrical loads that the unit will power. If powering
exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or
equipment for connection to a separate generator.
2. Connect the power cord of a 12V DC powered tool or equipment to the DC Terminals.
CAUTION: MAKE SURE TO CONNECT THE POSITIVE (+) LEAD OF THE
POWER CORD TO THE POSITIVE (+) TERMINAL ON THE GENERATOR,
AND CONNECT THE NEGATIVE (-) LEAD OF THE POWER CORD TO THE
NEGATIVE (-) TERMINAL ON THE GENERATOR.
THE 12V DC IS FOR BATTERY CHARGING ONLY.
24
12000W Dual-Fuel Generator
Spark Plug Service
rench (commercially available).
Recommended spark plugs: NHSP LD F7TC or NGKBPRGES but we recommend our OEM spark plug. To ensure proper engine operation, the spark plug must be properly gapped and free of deposits.
1. Remove the spark plug cap.
2. Clean any dirt from around the spark plug base.
3. Use a spark plug wrench to remove the spark plug.
4. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused.
5. Measure the plug gap with a feeler gauge.
The gap should be : 0.70-0.80 mm (0.028-0.031in)
6. Check that the spark plug washer is in good condition.
7. After the spark plug is seated, tighten with a spark plug in by hand to prevent cross-threading.
8 . After the spark plug is seated, tighten with a spark plug wrench to compress the washer.
NOTE: THE SPARK PLUG MUST BE SECURELY TIGHTENED. AN IMPROPERLY
TIGHTENED SPARK PLUG CAN BECOME VERY HOT AND COULD DAMAGE THE
ENGINE. NEVER USE SPARK PLUGS WHICH HAVE AN IMPROPER HEAT RANGE.
USE ONLY RECOMMENDED SPARK PLUG OR EQUIVALENT.
25
Owner’s Manual
Inspection, Cleaning, and
Maintenance
WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH IS IN ITS
“STOP” POSITION. DISCONNECT THE SPARK PLUG WIRE FROM THE ENGINE
AND ALLOW SUFFICIENT TIME FOR THE ENGINE AND GENERATOR TO
COMPLETELY COOL BEFORE PERFORMING ANY INSPECTIONS,
MAINTENANCE, OR CLEANING.
26
12000W
Dual-Fuel Generator
Fuel Sediment Cup Cleaning
The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor.
If the engine has not been run for a long time, the sediment cup should be cleaned.
1. Turn the fuel valve to the OFF position. Remove the sediment cup, and O-ring.
2. Clean the sediment cup and O-ring in nonflammable or high flash point solvent.
3. Reinstall O-ring, and sediment cup.
4. Turn the fuel valve ON and check for leaks.
27
Owner’s Manual
Maintenance Guide
Periodic maintenance and adjustment is necessary to keep the generator in good operating condition.
WARNING! Exhaust gas contains poisonous carbon monoxide. Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated.
• Before each use, inspect the generator. Check for:
- Loose screws
- Misaligned or binding moving parts
- Cracked or broken parts
- Damaged electrical wiring
- Any other condition that may affect safe operation.
• If an engine problem occurs, have it checked by a qualified service technician before further use.
Do not use damaged equipment.
• Before each use, make sure the engine’s oil and gas levels are adequate.
• Before each use, remove all debris with a soft brush, rag, or vacuum.
• Lubricate all moving parts using a premium quality, lightweight machine oil.
• E very 50 hours of use, drain the old engine oil and replace with a high quality
SAE 10W-30 grade engine oil.
• E very 300 hours of use, have a qualified, certified technician perform thorough maintenance on the generator and engine.
• For long term storage, either drain fuel into suitable container or add a fuel preservative/ stabilizer (not included) to prevent fuel breakdown.
Upper Level
28
12000W
Dual-Fuel Generator
Air cleaner service
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfuncion, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas.
WARNING! Using gasoline or flammable solvent to clean the filter element
can cause a fire or explosion. Use only soapy water or nonflammable
solvent.
NOTE: Never run the generator without the air cleaner. Rapid engine wear
will result.
1. Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element.
2. Wash the element in a solution of household detergent and warm water, then rinse thoroughly, or wash in nonflammable or high flash point solvent. Allow the element to dry thoroughly.
3. Soak the element in clean engine oil and squeeze out the excess oil. The engine will smoke during initial start-up if too much oil is left in the element.
4. Reinstall the air cleaner element and the cover.
29
30
Owner’s Manual before use before use before use
12000W
Dual-Fuel Generator
Transporting/Storage
1.Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container.
!
WARNING
Gasoline is extremely flammable and is explosive under certain conditions.
Perform this task in a well ventilated area with the engine stopped.
Do not smoke or allow flames or sparks in the area during this procedure.
DRAIN SCREW
2. Change the engine oil
3. Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the spark plug.
4. Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed. Storing the engine in this position will help to protect it from internal corrosion.
31
Owner’s Manual
Installation
NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE
GENERATOR’S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY IS
ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS THAT THE UNIT WILL
POWER. IF POWERING EXCEEDS THE GENERATOR’S CAPACITY, IT MAY BE
NECESSARY TO GROUP ONE OR MORE OF THE TOOLS AND/OR EQUIPMENT
FOR CONNECTION TO A SEPARATE GENERATOR.
Electrical and other permits may be required for the installation of emergency power systems.
Investigate your local building and electrical codes before installing this unit. Installation must be completed by licensed contractors.
WARNING! THE GENERATOR WEIGHS APPROXIMATELY 220 POUNDS. USE
CARE AND THE PROPER LIFTING OR HOISTING EQUIPMENT WHEN MOVING
IT TO THE INSTALLATION LOCATION. ALWAYS CONNECT HOIST LINES TO
THE FRAME OF THE GENERATOR.
General Location
• Make sure to locate and install the generator outdoors where cooling air is readily available.
• Install the generator so that the air inlets and outlets are not blocked by obstructions such as bushes, trees, or snow drifts. Locating it in the path of heavy winds or snowdrifts may require the placement of a barrier for protection. In normal weather conditions, the air vent should face the prevailing wind direction.
• Install the generator on a concrete slab or other area where rain drainage or flood waters can not reach it.
• Generator placement should allow four feet of access to all sides for maintenance.
• Place the generator as close as possible to the electrical tools and equipment being powered to reduce the length of extension cords.
32
12000W
Dual-Fuel Generator
Installation (cont’d)
Supporting and Mounting
Mount the generator on a concrete slab capable of supporting the weight of the generator. The slab must extend on all sides beyond the frame by at least one foot. Contact a cement contractor for slab specifications if necessary. Attach the frame to the concrete slab using 3/8” diameter expansion anchor bolts (not supplied).
Grounding
NOTE: IT IS RECOMMENDED THAT ONLY A TRAINED AND LICENSED
ELECTRICIAN PERFORM THIS PROCEDURE
Connect a #6 AWG grounding wire (not included) from the ground connector on the generator to a grounding rod (not included) that has been driven at least 24 inches deep into the earth. The grounding rod must be an earth-driven copper or brass rod (electrode) which can adequately ground the generator.
33
AC Load 120V/240V
9
000W (Gasoline) / 7
25
0W (Propane)
12
000 W (Gasoline) /
90
00W (Propane)
2-AC Duplex 120V Outlets,1-120V Twist-Lock Outlet,
1-120/240V Twist-Lock Outlet
EPA approved
459cc
76
/Propane
10
hours(approx.) @ 1/2 load
22
7
lbs.
34
PARTS LISTING
35
12000W
Dual-Fuel Generator
Cylinder head system assy.
APA Par t No.
APGG12000
-A-01-JD
APGG12000
-A-02-JD
APGG12000
-A-03-JD
APGG12000
-A-04-JD
APGG12000
-A-05-JD
APGG12000
-A-06-JD
APGG12000
-A-07-JD
APGG12000
-A-08-JD
APGG12000
-A-09-JD
APGG12000
-A-10-JD
APGG12000
-A-11-JD
APGG12000
-A-12-JD
APGG12000
-A-13-JD
JF240.1.1-3
JF340.2-4
JF168.10-1
JF240.1-4B
JF4
6
0.1.1
JF240.1-2B
JF4
6
0.2-3
JF340.2-5
JF240.1.3-1
JF340.1.1-2B
Description
HEAD COVER COMP
HEAD COVER PACKING
FLANGE BOLT (M10X80)
SPARK PLUG
EXHAUST PIPE STUD BOLT
CYLINDER HE A D C O M P
CARBURETOR S T U D B O L T
CYLINDER HE A D S E A L I N G P A D
DOWEL PIN (
BREATHER TUBE
Qty
1
1
1
1
1
2
1
2
1
4
1
2
1
A
36
12000W
Dual-Fuel Generator
Cylinder barrel
A P A P a r t N o .
JD Part No.
APGG12000
-B-01-JD
APGG12000
-B-02-JD
APGG12000
-B-03-JD
APGG12000
-B-04-JD
APGG12000
-B-05-JD JF460.2.1-1
APGG12000
-B-06-JD
APGG12000
-B-07-JD
APGG12000
-B-08-JD
APGG12000
-B-09-JD
APGG12000
-B-10-JD
APGG12000
-B-11-JD
APGG12000
-B-12-JD
APGG12000
-B-13-JD
APGG12000
-B-14-JD
APGG12000
-B-15-JD 20.2-6202
D e s c r i p t i o n
HEX HEAD FLANGE BOLT (M6X 12)
CRANK CASE
BALL BEARING (6202)
1
1
1
1
1
1
1
Qty
2
1
1
1
1
1
1
1
B
37
12000W
Dual-Fuel Generator
Crankcase cover system assy.
APA Par t No.
APGG12000
-C-01-JD
APGG12000
-C-02-JD
APGG12000
-C-03-JD
APGG12000
-C-04-JD
APGG12000
-C-05-JD
APGG12000
-C-06-JD
APGG12000
-C-07-JD
APGG12000
-C-08-JD
APGG12000
-C-09-JD
APGG12000
-C-10-JD
APGG12000
-C-11-JD
APGG12000
-C-12-JD
APGG12000
-C-13-JD
APGG12000
-C-14-JD
APGG12000
-C-15-JD
APGG12000
-C-16-JD
JD Part No.
JF340.17.3
20.4-M8*35
JF240.15-3B
JF340.15-5
20.1-35*52*7
JF340.15-2
JF340.15-1B
JF340.11.1-3
JF340.11.1.1
JF340.11.1-1
JF168.11.1-2
JF340.11.1.2
20.2-6202
20.2-6207
JF340.2-2
JF168.15-4
Description
DUCT COVER
FLANGE BOLT (M8 X 35)
OIL SCALE
OIL SCALE SEAL RING
OIL SEAL
FLANGE BOLT (M8X35)
CRANKCASE COVER
GOVERNOR SLIDER
GOVERNOR GEAR
SLIDER WASHER (6 mm)
GOVERNOR GEAR WASHER
SLIDER SHAFT
BALL BEARING (6202)
BALL BEARING (6207)
CRANKCASE COVER PAD
DOWEL PIN (8X12)
38
6
1
1
1
1
1
1
Qty
1
1
1
1
1
1
1
1
2
C
12000W
Dual-Fuel Generator
Crankshaft system assy.
2
A P A P a r t N o .
APGG12000
-D-0 1-JD
APGG12000
-D-02-JD
JD Part No.
JF4
6
0.4.2
JF
46
0.4-2
Descript io n
CRANKSHAFT COMP.(Tapper shaft)
BALANCER WEIGHT
D
Qty
1
1
39
12000W
Dual-Fuel Generator
Piston & Connecting Rod Assy.
A P A P a r t N o .
APGG12000
-E-01-JD
APGG12000
-E-02-JD
APGG12000
-E-03-JD
APGG12000
-E-04-JD
APGG12000
-E-05-JD
APGG12000
-E-06-JD
APGG12000
-E-07-JD
APGG12000
-E-08-JD
APGG12000
-E-09-JD
APGG12000
-E-10-JD
JF4
4
0.3-1C
JF4
4
0.3-2C
JF4
4
0.3-3C-1
JF4
4
0.3-3C-2
JF340.3-6
JF4
4
0.3-5C
JF390.3-4
JF420.3.1-1
JF340.3.1-2
JF340.3.1-3
Descript io n
C O M P R E S S I O N R I N G A
C O M P R E S S I O N R I N G B
O I L R I N G A
O I L R I N G B
P I S T O N P I N C L I P ( 2 0 m m )
P I S T O N
P I S T O N P I N
C O N N E C T I N G R O D
C O N N E C T I N G C O V E R
C O N N E C T I N G R O D B O L T
1
1
1
1
1
2
Qty
E
1
1
1
1
40
12000W
Dual-Fuel Generator
Valve Train Assembly
A P A P a r t N o .
APGG12000
-F-01-JD
APGG12000
-F-02-JD
APGG12000
-F-03-JD
APGG12000
-F-04-JD
APGG12000
-F-05-JD
APGG12000
-F-06-JD
APGG12000
-F-07-JD
APGG12000
-F-08-JD
APGG12000
-F-09-JD
APGG12000
-F-10-JD
APGG12000
-F-11-JD
APGG12000
-F-12-JD
APGG12000
-F-13-JD
APGG12000
-F-14-JD
APGG12000
-F-15-JD
APGG12000
-F-16-JD
JD Part No.
JF168.1.2-17
JF340.1.2-8
JF340.1.2-9
JF340.1.2-7
JF340.1.2-16
JF340.1.2-14
JF340.1.2-15
JF340.5
JF340.1.2-13
JF340.1.2-11
JF420.1.2-10
JF340.1.2-12
JF340.1.2-19
JF420.1.2-3
JF340.1.2-4B
JF340.1.2.1
Descript io n
P I V O T A D J U S T I N G N U T
R O C K E R A R M P I V O T
R O C K E R A R M
P I V O T B O L T ( M 8 )
P U S H R O D G U I D E P L A T E
R O D P U S H
V A L V E L I F T E R
C A M S H A F T
EX. VALVE HELMET
V A L V E S P R I N G R E T A I N E R
V A L V E S P R I N G
VALVE SPILT COLLAR
VALVE SPRING SEAT
E X .
V A L V E
I N .
V A L V E
OIL SEAL
Qty
2
1
1
2
2
2
2
2
2
2
1
2
4
2
2
F
1
41
12000W
Dual-Fuel Generator
Recoil Starter Assy.
1
A P A P a r t N o .
APGG12000
-G-01-JD
APGG12000
-G-02-JD
APGG12000
-G-03-JD
APGG12000
-G-04-JD
APGG12000
-G-05-JD
APGG12000
-G-06-JD
APGG12000
-G-07-JD
APGG12000
-G-08-JD
APGG7500-G-09-JD
APGG12000
-G-10-JD
APGG12000
-G-11-JD
APGG12000
-G-12-JD
JF340.13.1
JF340.13.1-7
JF340.13.1-6
JF340.13.1-8
JF340.13.1-5
JF340.13.1-4
JF340.13.1-3
JF340.13.1-9
JF340.13.1.1
JF340.13.1-2
JF340.13.1-1
20.4-M6*8
Descript io n
R E C O I L S T A R T E R A S S Y .
S E T T I N G S C R E W
S P R I N G R E T A I N E R
P L A T E N S P R I N G
S T A R T E R D E T E N T
D E T E N T S P R I N G
R E C O I L S T A R T E R R E E L
S T A R T R E T U R N S P R I N G
R E C O I L S T A R T E R C A S E C O M P .
R E C O I L S T A R T E R R O P E
S T A R T E R K N O B
F L A N G E B O L T ( M 6 X 8 )
Qty
1
1
1
2
1
1
1
1
1
2
2
3
G
42
12000W
Dual-Fuel Generator
Fan Cover Assy.
A P A P a r t N o .
APGG12000
-H-01-JD
APGG12000
-H-02-JD
APGG12000
-H-03-JD
JD Part No.
JF420.12-1
20.4-M6*12
JF
4
40.13.2
Descript io n
S H R O U D
F L A N G E B O L T ( M 6 X 1 2 )
F A N C O V E R C O M P .
Qty
1
4
1
H
43
12000W
Dual-Fuel Generator
Carburetor Assy.
1
2
APA Par t No.
APG1
2
000GL-I-01-JD
APG1
2
000GL-I-02-JD
APG12000
-I-03-JD
APG12000
-I-04-JD
APG12000
-I-05-JD
JD Part No
JF420GL.9-4
JF460GL.9.2
JF340.9-3
JF340.9-1A
JF340.1-3
3
4
5
Description
PROPANE SUPPLY HOSE
CARBURETOR
CARBURETOR PAPER GASKET
CARBURETOR INSULATING PLATE
INTAKE PIPE GASKET
Qty
1
1
1
1
1
I
44
12000W
Dual-Fuel Generator
Flywheel Assy.
5
2
4
A P A P a r t N o .
APGG12000
-J-01-JD
APGG12000
-J-02-JD
APGG12000
-J-03-JD
APGG12000
-J-04-JD
APGG12000
-J-05-JD
JD Part No.
JF4
4
0.4.1
JF168.4.2-2
JF340.12-1
JF340.13-1
JF240.4-1
3
Descript io n
F L Y W H E E L
S P E C I A L W O O D R U F F K E Y
C O O L I N G F A N
S T A R T E R P U L L E Y
F L Y W H E E L N U T ( M 1 6 )
Qty
1
1
1
1
1
J
45
12000W
Dual-Fuel Generator
Ignition System Assy.
A P A P a r t N o .
APGG12000
-K-01-JD
APGG12000
-K-02-JD
APGG12000
-K-03-JD
APGG12000
-K-04-JD
APGG12000
-K-05-JD
APGG12000
-K-06-JD
JF340.10.2-1
JF340.10.2-2
JF340.10.2-3
JF340.10-3
20.4-M6*25
JF340.12-4
Descript io n
NOISE SUPPERSSOR CAP ASSY
IGNITION COIL ASSY
STOP SWITCH CORD
STOP SWITCH CORD HOLDER
FLANGE BOLT (M6 X 25)
CORD GROMMENT
Qty
1
1
1
1
1
K
46
12000W
Dual-Fuel Generator
Starter Motor Assy.
APA Par t No.
APGG12000
-L-01-JD
APGG12000
-L-02JD
APGG12000
-L-03-JD
JD Part No.
JF340.18-1
JF340.18-2
20.4-M8*35
Descript io n
S T A R T E R M O T O R
SOLENOID
FLANGE BOLT (M8×35)
Qty
1
1
2
L
47
12000W
Dual-Fuel Generator
Control Assy.
A P A P a r t N o .
APGG12000
-M-01-JD
APGG12000
-M-02-JD
APGG12000
-M-03-JD
APGG12000
-M-04-JD
APGG12000
-M-05-JD
APGG12000
-M-06-JD
APGG12000
-M-07-JD
APGG12000
-M-08-JD
APGG12000
-M-09-JD
APGG12000
-M-10-JD
APGG12000
-M-11-JD
JD Part No.
JF340.11.4
JF340.11.4-1
JF340.11.4-3
JF340.11.4-4
20.4-M6*12
JF340.11.2-5A
JF340.11.2-6
JF340.11.2-7
20.6-M6
JF168.11.2-3
JF340.11.2-4
Descript io n
C O N T R O L A S S Y .
C O N T R O L B A S E C O M P .
C O N T R O L A D J U S T I N G S P R I N G
P A N S C R E W ( M 5 X 3 4 )
F L A N G E B O L T ( M 6 X 1 2 )
T H R O T T L E R E T U R N S P R I N G
G O V E R N O R S P R I N G
G O V E R N O R R O D
F L A N G E N U T ( M 6 )
G O V E R N O R A R M B O L T ( M 6 )
C O N T R O L A R M
1
1
1
1
1
Qty
1
1
1
1
1
1
M
48
12000W
Dual-Fuel Generator
Muffler Assy.
3
4
APA Par t No.
APG12000
-N -01-JD
APG12000
-N -02-JD
APG12000
-N -03-JD
APG12000
-N -04-JD
APG12000
-N -05-JD
APG12000
-N -06-JD
APG12000
-N -07-JD
APG10000-N -08-JD
APG12000
-N -09-JD
APG12000
-N -10-JD
APG12000
-N -11-JD
APG12000
-N -12-JD
Descript io n
20.4-M8*16
20.4-M6*12
JD6500.17.10.1.5-1
JD6500.17.10.1.5-2
JD6500.17.10.1.5-3
JF340.7.2-3
JF340.7.2-1
JF240.7.2-2
JF240.7-1
JF290.7.2.1
20.4-M8*25
20.6-M8
Part No.
FLANGE BOLT (M8 X 16) 4
4 FLANGE BOLT (M6 X 12)
MUFFLER STAY COMP. 1
1
MUFFLER PROTECTOR SEAL
MUFFLER SIDE PROTECTOR
1
MUFF. INNER PROTECTOR COM 1
MUFFLER COMP 1
MUFF. OUTER PROTECTOR COM
EX. PIPE GASKET
1
1
EX PIPE COMP.
1
FLANGE BOLT (M8 X 25)
2
FLANGE NUT (M8) 2
N
49
12000W
Dual-Fuel Generator
Air Cleaner
APA Part No. JD Part No.
APGG12000
-O-01-JD
APGG12000
-O-02-JD
APGG12000
-O-03-JD
APGG12000
-O-04-JD
APGG12000
-O-05-JD
APGG12000
-O-06-JD
APGG12000
-O-07-JD
Description
AIR CLEANER COVER COMP
AIR CLEANER ELEMENT
FLANGE NUT (M5)
AIR CLEANER SEPARATOR
AIR CLEANER SEAL
AIR CLEANER CASE COMP
BREATHER GASKET
1
1
1
1
Qty
1
1
6
O
50
12000W
Dual-Fuel Generator
Fuel Tank Assy.
1
2
9
10
5
6
3
4
8
6
7
APA Par t No.
APGG1
2
000 -P-01-JD
APGG1
2
000 -P-02-JD
APGG1
2
000 -P-03-JD
APGG1
2
000 -P-04-JD
APGG1
2
000 -P-05-JD
APGG1
2
000 -P-06-JD
APGG12000
-P-07-JD
APGG1
2
000 -P-08-JD
APGG1
2
000 -P-09-JD
APGG1
2
000 -P-10-JD
JD Part No
JD6500W-U.1.5-1.2
JD6500W-U.1.5-1.1
JD10000W-U.1.5-1C
JF168.8-1A
JF168.8-5
JF168.8-3
JF168.8-6
JF168.8-7
20.4-M6*25
JF168.8.2.1-4
Descript io n
FUEL TANK CAP COMP.
FUEL FILTER
FUEL TANK COMP.
FUEL TUBE
FUEL SWITCH
CLAMP, FUEL TUBE
EVAPORATIVE TUBE
SPRING, EVAPORATIVE TUBE
FLANGE BOLT (M6x25)
RUBBER
2
1
2
1
1
Qty
1
1
1
4
4
P
APGG 7500-P- 10- JD FUEL TANK JOINT
APGG 7500-P- 11- JD TUBE CLI P
APGG 7500-P- 12- JD FUEL TUBE
51
JD3800- D- 10
JD3800- D- 11
JD3800- D- 12
12000W
Dual-Fuel Generator
Control Box Assy.
4
10
1
2
APA Part No.
APGG12000
-Q-01-JD
APGG12000 -Q-02-JD
APGG12000
-Q-03-JD
APGG12000 -Q-04-JD
APGG12000
-Q-05-JD
APGG12000
-Q-06-JD
APGG12000 -Q-07-JD
APGG12000
-Q-08-JD
APGG12000 -Q-09-JD
APGG12000
-Q-10-JD
APGG12000
-Q-11-JD
APGG12000 -Q-12-JD
APGG12000
-Q-13-JD
APGG12000 -Q-13-JD
13 14 3 11 6
JD Part No.
HC001-MB
21.3.1-13
21.3.4-15
21.3.16-2
21.3.4-5
21.3.7-7
21.3.4-6
21.3.4-7
21.3.24
21.3.25-11
21.3.11-4/10A
21.3.7-10
21.3.9-6
21.3.9-3
12 5 5 7 8 9
Description
CONTROL PANEL COMP.
ENGINE SWITCH ASSY.
DC 12V OUTPUT
HOURS METER
120V RECEPTACLE(Ru-22)
CIRCUIT BREAKER (SINGLE, 20A)
120V RECEPTACLE(L5-30)
120V/240V RECEPTACLE
EARTH TERMINAL SET
CONTROL PANEL CASE
DC CIRCUIT PROTECTOR(10A)
CIRCUIT BREAKER (DOUBLE, 30A)
POWER LAMP
OIL ALERT LAMP (RED,
Ф
12)P
1
1
1
1
1
1
1
1
1
1
Q
QTY
1
1
1
1
52
12000W
Dual-Fuel Generator
Frame Comp Assy.
2
1
APA Part No.
APGG12000
-R-01-JD
APGG12000 -R-02-JD
JD Part No.
JD6500.17.10.1-J109
Description
GENERATOR FRAME
CONTROL PANEL CASE
Qty
1
1
R
53
12000W
Dual-Fuel Generator
Generator
7 11
APA Part N o.
APGG12000
-S-01-JD
APGG12000
-S-02-JD
APGG12000
-S-03-JD
APGG12000
-S-04-JD
APGG12000
-S-05-JD
APGG12000
-S-06-JD
APGG12000
-S-07-JD
APGG12000
-S-08-JD
APGG12000
-S-09-JD
APGG12000
-S-10-JD
APGG12000
-S-11-JD
APGG12000
-S-12-JD
APGG12000
-S-13-JD
APGG12000
-S-14-JD
APGG10000 -S-15-JD
APGG12000
-S-16-JD
APGG12000
-S-17-JD
JD Part No
7KW.25.3A
7.5KW.25.02B
5KW.25.2-8A
5KW.25.4A
20.4-M5*16*0.75
JF240.22-1
20.9-M5
20.3-M6*187
AVR-7KW
JF240.22-3
20.9-M5
20.7-M5*12*0.75
7.5kW.25.02C
20.2-6204RS
20.9-M10
20.4-M10*273*1.25
20.3-M5*222*0.8
54
Description
STATOR COVER
STATORASSY
COOLING FAN
BRUSH ASSY
TAPPING SCREW
RR HOUSING
SPRING WASHER (5mm)
FLANGE BOLT (M6X 179)
AUTO VOLTAGE REG. ASSY
GENERATOR COVER
HEX.NUT (M5)
FLANGE BOLT
ROTOR COMP
BEARING ASSY
PLAIN WASHER
FLANGE BOLT (M10)
FLANGE BOLT (M5)
1
1
4
2
1
3
1
4
4
1
1
1
2
1
1
Qty.
1
1
S
12000W
Dual-Fuel Generator
Generator
APA Part No. JD Part No.
APGG12000
-S-18-JD 20.4-M5*16*0.75
APGG12000
-S-19-JD
APGG12000
-S-20-JD
2KW.25.5-1
20.9-M5
Description
HEX.BOLT (M5 X 20)
VOLT CHANGE TERMINAL BR-AC-W
PLAIN WASHER (5mm)
Qty
2
1
4
55
12000W
Dual-Fuel Generator
Wheel & Hand Assy.
3
7
7
14
14
16
15
1 2
12
2
6
4
6
12
7
7
15
16
5
4
6 6
2
14
14
13
9
9 9
9
13
APA Part N o
APGG1
2
000 -T-01-JD
APGG1
2
000 -T-02-JD
APGG1
2
000 -T-03-JD
APGG1
2
000 -T-04-JD
APGG1
2
000 -T-05-JD
APGG1
2
000 -T-06-JD
APGG1
2
000 -T-07-JD
APGG1
2
000 -T-08-JD
APGG1
2
000 -T-09-JD
APGG1
2
000 -T-10-JD
APGG1
2
000 -T-11-JD
APGG12000
-T-12-JD
APGG1
2
000 -T-13-JD
APGG1
2
000 -T-14-JD
APGG1
2
000 -T-15-JD
APGG1
2
000 -T-16-JD
11
10 11
8
8
JD Part No
JD6500.17.10.1-1
JD6500.17.10.1-2
8 inch wheel
JD6500.17.10.1-J109.1-1
JD6500.17.10.1-J109.1
20.4-M6*45
20.6-M6
JD6500.17-1
20.6-M8
JD6500.17.10.1-J109.3
20.3-M8*22
20.5-M8
JD6500.17.10.1-J109.2
20.4-M8*48 (square-head)
JD6500.17.10.1-J109.2-1
20.4-M8*45
56
3
2
1
Description
PIN SPLIT
WSHER PLAIN
WHEEL
BAFFLE
SHAFT
FLANGE BOLT (M6X 45)
FLANGE NUT (M6)
RUBBER BOLT
FLANGE NUT(M8)
STANDER
FLANGE BOLT (M8X 22)
FLANGE NUT (M8)
HANDLE
BOLT (M8X48 )
BRACKET WITH LOCK PIN
FLANGE BOLT(M8X45)
6
2
4
2
2
2
6
1
2
4
4
T
Qty.
2
4
2
2
1
Advertisement