Technical Specifications:
Operating Pressure:
Min: 100kPa/1bar
Max: 500kPa/5bar*
Optimum: 150kPa/1.5bar - 500kPa/5bar
Operating Temperature:
Hot: Max 70°C*
Cold: Min 5°C
Inlet Connections:
½ " BSP
* Regional specific regulations apply.
Please refer to your warranty statement at www.methven.com
www.methven.com
•
•
•
•
IMPORTANT: Please read all of the instructions before installation.
General:
• Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.
After installation all connections must be checked for leaks.
All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.
It is the responsibility of the installer to ensure a waterproof seal is achieved.
NOTE: Some showers may not provide an e ff ective shower when used with gravity fed heated water systems or where pressures are less than 150kPa/1.5bar at the outlet. Additionally showers with flow rates of less than 9L/min may not allow the following to function correctly:
- some instantaneous water heaters
- some tempering valves
- some thermostatic mixing valves
Care and Cleaning:
Never use abrasives or abrasive cleaning agents to clean this product. Clean regularly with contamination free warm soapy water and a damp soft cloth.
A filter washer should be installed in the hose cone on the water outlet and it should be cleaned periodically.
If shower performance is compromised by the build-up of lime-scale, soak in limescale remover for up to 10 minutes. Do not use products containing chlorine bleach or hydrochloric acid as these can damage the shower. Always rinse the shower thoroughly after cleaning to remove cleaning products that can damage the shower.
Never insert objects into the spray slot or attempt to remove limescale with sharp objects or abrasives.
Methven warrants this product against manufacturing defects and that it is suitable for use under the general operating conditions specified in this instruction sheet. However, regional regulations apply and may a ff ect your warranty. Please refer to www.methven.com
or call customer service for full details.
New Zealand
0800 804 222
439910
Australia
1300 638 483
UK
0800 195 1602
ISSUE B
Care and Cleaning:
Never use abrasives or abrasive cleaning agents to clean this product. Clean regularly with contamination free warm soapy water and a damp soft cloth.
Periodically the filter washer should be removed from the end of the shower hose and cleaned.
WALL OUTLET BRACKET
Installation Guide
Technical Specifications:
Operating Pressure:
Min: 35kPa/0.35bar
Max: 1000kPa/10bar*
Optimum: 150kPa/1.5bar - 500kPa/5bar
Operating Temperature:
Hot: Max 80°C*
Cold: Min 5°C
Inlet Connections:
All ½ " BSP
* Regional specific regulations apply.
Please refer to your warranty statement at www.methven.com
Methven warrants this product against manufacturing defects and that it is suitable for use under the general operating conditions specified in this instruction sheet. However, regional regulations apply and may a ff ect your warranty. Please refer to www.methven.com
or call customer service for full details.
New Zealand
0800 804 222
439911
Australia
1300 638 483
UK
0800 195 1602
ISSUE A
www.methven.com
•
•
IMPORTANT: Please read all of the instructions before installation.
General:
• Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.
After installation all connections must be checked for leaks.
All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.
• It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall using silicone to ensure a seal is achieved.
Outlet Bracket
Faceplate
Inlet Connector
O-ring
IMPORTANT: Before you begin, turn o
ff
the water supply.
•
•
Step 1
Wall lining hole should be cut or finished as per the dimension shown in the diagram on the right.
Cut o ff the threaded nipple 15±2mm from the wall lining and apply thread seal tape to ensure a good seal.
•
•
Step 2
Insert faceplate o-ring into the groove in the faceplate and slide the faceplate over the nipple.
Secure faceplate in place by screwing the inlet connector onto the nipple.
½ " BSP Nipple
(Not Supplied)
•
•
Step 3
Ensure outlet bracket o-ring is located on faceplate.
Firmly push the outlet bracket onto the inlet connector and secure in place by tightening the grub screw firmly using the hex key provided.
15±2mm
26mm max
Grub Screw
Hex Key
•
•
Step 4
Connect hose to outlet bracket and handset.
Ensure swivelling cone is connected to the handset.
Filter Washer
Non-Swivelling Cone
Handset
Flat
Washer
Swivelling
Cone