American Standard Serin Petite Monoblock Single Hole Single Handle Bathroom Faucet installation Guide

Add to My manuals
7 Pages

American Standard 2064.131.295 is a monobloc lavatory faucet featuring the innovative Speed Connect drain system, designed for quick and easy installation. The faucet's sleek design complements various bathroom styles, and its durable construction ensures longevity. The Speed Connect drain eliminates the need for adjustments, ensuring a proper seal every time.

advertisement

American Standard Serin Petite Monoblock Single Hole Single Handle Bathroom Faucet installation Guide | Manualzz

SERIN

PETITE

Installation

Instructions

2064.131

MONOBLOCK LAVATORY FAUCET with

Speed Connect™ Drain

Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on

American Standard faucets.

Speed Connect Drain*

• Fewer parts, installs in less time

• Never needs adjustment

• Guaranteed to seal properly the first time, every time.

Certified to comply with ANSI A112.18.1

*Your new American Standard faucet is designed to work only with the Speed Connect drain.

To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.

M 9 6 5 3 6 3

Recommended tools

CAUTION

Channel Locks

Turn off hot and cold water supplies before beginning.

Adjustable Wrench Screwdriver

1

INSTALL FAUCET

Installation with ESCUTCHEON PLATE #2064101P: Note; Escutcheon plate not included with fitting and must be ordered separately.

Apply a light bead of plumbers putty to underside of ESCUTCHEON PLATE (8) if mounting surface is uneven.

Place ESCUTCHEON PLATE (8) onto sink or mounting surface.

Seat

SEAL (1) into under side of FAUCET BASE (2) . Feed FAUCET SUPPLIES (3) ,

MOUNTING STUD (4) and DRAIN CABLE ASSEMBLY (8) through ESCUTCHEON

PLATE (9) and mounting hole of lavatory or mounting surface.

Fig. A.

Installation less ESCUTCHEON PLATE:

Seat SEAL (1) into under side of FAUCET BASE (2) .

Feed FAUCET SUPPLIES (3) , MOUNTING STUD (4) and

DRAIN CABLE ASSEMBLY (8) through the mounting hole of lavatory or mounting surface. Fig. B.

9

Fig.

A.

2

1

Tubing Cutter

GROOVE

(FAUCET

BASE)

4

Fig.

B.

COLLAR ON

MOUNTING NUT

7

5

6

4

Figure B

Fig.

C.

2

1

3

From below, push GASKET (7) and RETAINING WASHER (5) onto

MOUNTING STUD (4) . Secure Faucet with MOUNTING NUT (6) , pulling faucet to front of sink, so SUPPLIES (3) rests against mounting hole. Before final tightening, make sure collar on

MOUNTING NUT (6) is seated into RETAINING WASHER (5) .

Fig. C .

Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6) to complete faucet mounting.

1

5

GROOVE

(FAUCET

BASE)

4

3

MOUNTING

SURFACE

PUTTY

IF REQUIRED

8

2

POP-UP DRAIN

Remove CLEAR PLASTIC COVER (1) .

Remove CARDBOARD SPACER (2) from under

DRAIN POP-UP (3) .

Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig.

B.

Fig.

A.

1

3

2

3

REMOVE FLANGE

Thread FLANGE (1) counter-clockwise and remove

FLANGE (1) and FOAM GASKET (2) from drain body. Fig.

A.

Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against

LOCKNUT (3). Fig.

B.

Fig.

A.

1

2

4

3

Fig.

B.

Fig.

B.

DRAIN

BODY

4

4

INSTALL DRAIN FROM

BELOW FIXTURE

From under side of SINK install DRAIN BODY (1) up through drain outlet.

Note: No plumber’s putty or caulk is required.

The CABLE ATTACHMENT

POINT (2) must face towards the rear of the SINK.

Install FOAM GASKET (3) and

FLANGE (4) onto drain body from above SINK and tighten

FLANGE (4) firmly.

4

3

REAR OF SINK

DRAIN

OUTLET

1

2

6

FLANGE GASKET AND POP-UP KNOB

Check DRAIN FLANGE in SINK to ensure that

WHITE FOAM GASKET (3) is fully compressed and not visible. Fig.

A.

POP-UP KNOB (1) must be fully down. Fig.

B.

Fig.

A.

WHITE FOAM

GASKET

NOT VISIBLE

5

TIGHTEN LOCKNUT

Tighten LOCKNUT (1) firmly with Adjustable

Wrench or Channel Locks.

DRAIN

FLANGE

DOWN

1

1

M 9 6 5 3 6 3

2

7

ATTACH CABLE CONNECTOR

Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig.

A.

Your new POP-UP DRAIN installation is now complete. Fig.

B.

Note: Tailpeice on pop-up drain is 1-1/4” O.D.

Fig.

B.

Fig.

A.

1

Fig.

B.

2

1-1/4” O.D.

8

CHECK OPERATION OF POP-UP

Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.

Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.

1

2

9

MAKE WATER SUPPLY AND WASTE CONNECTIONS

Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.

Connection on fitting supplies are 3/8" compression. Connect left SUPPLY (1) to Hot (Marked with a Red Band) and right supply to COLD (2) wall supply.

Faucet supplies are 20" long from faucet base.

Note: If additional supply length is required, installer must purchase additional parts separately.

Important: If SUPPLY HOSES (1, 2) are to long, loop as illustrated to avoid kinking.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.

APPROX. 20 "

1

HOT

RED

BAND

2

BLUE

BAND

3/8" COMPRESSION

COLD

M 9 6 5 3 6 3

3

10

TEST INSTALLED FITTING

With HANDLE (1) in OFF position, turn on WATER

SUPPLIES (2) and check all connections for leaks.

Remove AERATOR (3) .

Operate HANDLE (1) to flush water lines thoroughly.

Replace AERATOR (3) .

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (4) and fill Bidet with water.

Check that DRAIN STOPPER (5) makes a good seal and retains water in Bidet. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.

Release POP-UP KNOB (4) down and check all drain connections and "P" trap for leaks. Tighten if necessary.

WASTE

OUTLET

4

5

ON

HOT

OFF

COLD

1

11

SERVICE CAUTION Turn off hot and cold water supplies before beginning.

To remove or replace cartidge:

Turn valve to OFF position.

Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2) .

Pull off HANDLE (3) and CAP (4) .

Unthread CARTRIDGE NUT (5) and remove.

Pull out CARTEIDGE (6) .

Inspect CARTRIDGE (6) and O-RINGS (7) for debris and clean if necessary.

Clean MANIFOLD (8) and rinse clean.

Reinstall CARTRIDGE (6) and O-RINGS (7) onto MANIFLOD (8) .

Reinstall CARTRIDGE NUT (5) , CAP (4) and HANDLE ASSEMBLY (3) .

If spout drips, operate handle several times from OFF to ON and

HOT to COLD position. Do not force - handle turns only 90˚.

2

“P” TRAP

2.5mm HEX KEY

3

1

2

REMOVE INSTALL

4

5

10

6

2

3

7

8

12

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

M 9 6 5 3 6 3

4

Speed Connect™ Drain

Troubleshooting Guide

If sink does not hold water even though Stopper is in the “down” position:

• Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

• Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

• Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:

• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode .

CABLE ADJUSTMENT PROCEDURE

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig.

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as

“Cam” in the illustration. Fig.

B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the

Stopper should be in the UP position. Fig.

B, C.

Push DOWN on the Lift-Knob to make sure it is fully down. Fig.

C.

Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the

Drain Body Connection (2) and hand-tighten. Fig.

A.

Fig.

A.

Fig.

B.

Fig.

C.

DOWN

CAM 1

RE-ATTACH

1

CAM CAP

DISCONNECT

2

STOPPER

STOPPER REMOVAL PROCEDURE

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig.

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig.

B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig.

D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig.

E.

The Stopper can now be removed by lifting it out of the Drain. Fig.

F.

Fig.

D.

Fig.

E.

REMOVE

CAM

Fig.

F.

REMOVE

CAM CAP

M 9 6 5 3 6 3

5

STOPPER INSTALLATION PROCEDURE

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).

Locked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig.

G.

To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the

Sink and the American Standard logo is facing front . Rotate

Stopper slightly if necessary so that the Stopper slides all the way down.

Fig.

G.

Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig.

J.

Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig.

K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.

LOGO

LOOP TOWARD

REAR OF SINK

DRAIN

Locked Mode

(Vandal Proof)

Fig.

G.

Unlocked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig.

H.

To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the

Sink and the American Standard logo is facing rear . Rotate Stopper slightly if necessary so that the Stopper slides all the way down.

Fig.

H.

Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig.

J.

Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig.

K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

“Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable .

LOGO

180˚

Fig.

LOOP TOWARD

FRONT OF SINK

DRAIN

Unlocked Mode

H.

Fig.

J.

INSTALL CAM

CAM

Fig.

K.

INSTALL

CAM CAP

M 9 6 5 3 6 3

6

M964233-YYY0A

POP-UP ROD

M962492-0070A

MOUNTING KIT

M918462-0070A

CABLE ADAPTER

M 9 6 5 3 6 3

SERIN ™ PETITE

MONOBLOCK

LAVATORY FITTING

MODEL NUMBER

2064.131

M964247-YYY0A

HANDLE KIT

607641-YYY0A

CARTRIDGE CAP

603275-0070A

CARTRIDGE NUT

Replace the "YYY" with appropriate finish code

CHROME

SATIN NICKEL

002

295

M954878-0070A

CARTRIDGE

M922881-YYY0A

AERATOR

M962421-YYY0A

ESCUTCHEON KIT

M952425-YYY0A

DRAIN ASSEMBLY

M962544-YYY0A

STOPPER

ASSEMBLY

M952430-0070A

CABLE ASSEMBLY

M962457-YYY0A

FLANGE

ASSEMBLY

M922872-0070A

CAM SEAT INSERT

M962552-0070A

CAM ASSEMBLY

M913207-0070A

TAILPIECE INSERT

A919661-0020A

TAILPIECE

M962458-0070A

DRAIN MOUNTING KIT

2064101P

ESCUTCHEON PLATE

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1 (800) 442-1902

Weekdays 8:00 a.m. to 6:00 p.m. EST

IN MEXICO 01-800-839-1200

IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

Product names listed herein are trademarks of American Standard Inc.

© AS America,Inc. 2012

7

advertisement

Related manuals

Download PDF

advertisement