Monte Carlo York 52 in. Matte Black Ceiling Fan Installation manual

Add to my manuals
8 Pages

advertisement

Monte Carlo York 52 in. Matte Black Ceiling Fan Installation manual | Manualzz

Owner’s Guide and Installation Manual

5YK52XXX Series Fan

CUL Model NO. : 5YK52XXX

Attach sales receipt to this card and retain as your proof of purchase

DATE OF PURCHASE:

MODEL NUMBER:

RETAILER NAME:

RETAILER ADDRESS:

To register your fixture, please visit our website www.montecarlofans.com

7.6 kgs

16.72 lbs

Total fan weight

Cautions and Warnings

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA

70) including fire-rated construction.

Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed carefully up into the outlet box.

WARNING: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

WARNING: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of

15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION : For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove

Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the building structure (or the ceiling joist).

WARNING: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING: To reduce the risk of fire or electric shock, do not use this fan with any unverified solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

Never place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the

American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit.

All set screws must be checked and tightened where necessary before installation.

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077 www.montecarlofans.com

2

© 2018 Monte Carlo Fan Company 10/2018

1 2 3

ON

ON

OFF

OFF

Mounting bracket

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

Use AC 120V/60HZ power supply only.

Before installing this fan make sure the outlet box is properly installed to the house structure. To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support.

(Mounting must support at least 35 lbs.)

Use metal outlet box suitable for fan support and use only the screws provided with the outlet box (must support 35 lbs).

Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member ( a loose box will cause the fan to wobble). Remove the two outlet box screws provided with the box, aligning the holes of the mounting bracket with the holes of the outlet box. Reinstall the 2 outlet box screws securely.

4

Downrod Mount Installation

5

Downrod

Cross pin

Keeper pin

Canopy

Canopy bottom disc

Downrod

Yoke cover

6

Cross pin

Keeper pin

Partially loosen downrod set screws from yoke at top of motor assembly.

Remove preassembled cross pin and keeper pin from downrod.

Place downrod over canopy, canopy bottom disc and yoke cover. Thread lead wires and safety cable from motor assembly through downrod.

Slip downrod into motor housing yoke, aligning holes and install cross pin and keeper pin.

Insert cross pin through yoke and downrod until point appears on the other side, and insert keeper pin on cross pin.

Pull the downrod up tight against the cross pin, and then evenly tighten the downrod set screws on motor housing yoke.

Place yoke cover on top housing of fan.

Warning : Cross pin and keeper pin must be installed securely, failure to install them will result in serious injury.

3

© 2018 Monte Carlo Fan Company 10/2018

7 8

SAFETY CABLE INSTALLATION

9

Tab

Slot

Lag screw

Safety cable switch

White

(Neutral)

Black

(Live)

Ground/Green

Black

Blue

White

Washer

Lock washer

Install ball end of downrod into mounting bracket opening. Align (engage) slot on ball with tab on mounting bracket.

Warning: Failure to align slot on ball with tab may result in serious injury.

Important : If using the angle mount, make sure open end of mounting bracket is installed facing the higher point of the ceiling and make sure the ceiling angle is not steeper than 30º.

For Canadian installation and for USA fan and light kit combinations over 35 lbs, in both flush and downrod modes the safety cable must be installed into the house structure beams using 3” lag screws, washers and lock washers provided.

Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires.

Note : If Installing The Secondary Support

Safety Cable in the U.S., Do Not Remove

Knockouts In The Outlet Box.

Make wiring connections using wire connectors provided as indicated above.

White from fan to White (Neutral) from house. Black and Blue from fan to Black

(Live) from house. Connect all green grounded wires to Grounded wire from

House. Make sure that no filaments are outside of the wire connectors.

10 11

Ungrounded wires

Stud

Go to step 19 to finish installation

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices after being made should be turned upward and pushed carefully up into the outlet box.

Lift Canopy allowing the 2 studs to protrude through the canopy.

Next lift the cover ring and install knurled nuts as shown. Tighten the knurled nuts securely. The canopy should adjust for any irregularity in the ceiling or Outlet box.

Make sure the studs protruding from the bottom of the Mounting bracket are installed with threads all the way through the bracket.

4

© 2018 Monte Carlo Fan Company 10/2018

12

Flush Mount Installation

13

Side cover

Rubber pad

14

Remove every other screws from yoke located on top of fan assembly. Keep screws.

Note : Flush mount is not available with vaulted ceiling.

Remove side covers from canopy exposing 4 holes. 2 closed holes and 2 open “L” shape holes.

Place rubber pad and canopy over lead wire and safety cable and align the larger holes in canopy and holes on rubber pad with the set screws on yoke.

Reinstall the 3 set screws remove in step

12. Tighten screws securely.

15 16

SAFETY CABLE INSTALLATION

17 White

(Natural) Wall switch

Hook

Black

(Live)

Black

Blue

White

Lag screw

Safety cable

To prepare the fan for wiring, hang fan onto mounting bracket by sliding the canopy over the mounting bracket hook

( Use one of non-slotted holes on the rim of the canopy ).

© 2018 Monte Carlo Fan Company

Washer

Lock washer

For Canadian installation and for USA fan and light kit combinations over 35 lbs, in both flush and downrod modes the safety cable must be installed into the house structure beams using 3” lag screws, washers and lock washers provided.

Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires.

Note : If Installing The Secondary Support

Safety Cable in the U.S., Do Not Remove

Knockouts In The Outlet Box.

Make wiring connections using wire connectors provided as indicated above.

White from fan to White (Neutral) from house. Black and Blue from fan to Black

(Live) from house. Connect all green grounded wires to Grounded wire from

House. Make sure that no filaments are outside of the wire connectors.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices after being made should be turned upward and pushed carefully up into the outlet box.

5

10/2018

18 19 20

Blade

Install 2 of the screws to the side panel of mounting bracket corresponding to the open slotted holes on the canopy upper rim, screws provided. Remove the thread studs from the lower part of the mounting bracket.

Lift fan to mounting bracket, aligning the

“L” shape holes on canopy with the screws on the mounting bracket. Turn the fan clockwise to lock in position. Install the other 2 canopy mounting set screws from the hardware pack and tighten all screws securely.

Blade bracket

Install blade bracket with blade by 3 blade screws and washers provided. Tighten screws securely. Repeat this process for remaining blades.

Shipping stabilizers

Remove shipping stabilizers from motor assembly.

Install the blade assembly to motor using the preinstalled screws. Tighten screws securely. Repeat this process for remaining blade assemblies.

21 22

Loosen 2 and remove 1 preassembled screw from top plate of switch housing.

Reverse switch

Connect the quick connectors from fan and switch housing. Make sure quick connectors are clasped firmly.

Install the switch housing onto the top plate, aligning the keyhole slots on the switch housing with the preassembled screws on top plate and twist it clockwise till lock. Reinstall the set screw removed in step 21 and tighten all screws securely.

Install fan pull chain to preassembled pull chain on fan. Pull chain provided.

Setting the reverse switch in the left hand side will result in downward airflow and setting the switch in the right hand side will result in upward airflow.

Note : Reverse switch must be set either way completely. If the reverse switch is set in the middle position, fan will not operate.

6

© 2018 Monte Carlo Fan Company 10/2018

Trouble Shooting

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, installation, please call our Customer Service Center at the number printed on your parts list insert sheet.

Warning means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Trouble Suggested Remedy

1. If fan does not start: 1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION either way. Fan will not operate when switch is in the middle.

4.If this fan uses remote controller, make sure dip switches are setting properly and make

2. If fan sounds noisy:

3. If fan wobbles:

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing.

CAUTION

4.Check to be sure light bulb is tight in socket and not touching the glass shade.

5.Some fan motors are sensitive to signals from Solid State variable speed controls.

6.Allow "break-in" period of 24 hours. Most noises associated with a new fan will disappear after this period.

1.If this is a downrod mount fan, make sure the ridge on mounting bracket engages the notch in the downrod ball.

2.Make sure that canopy, mounting bracket or mounting plate are tightened securely to

4.Check that all blade holders are tightened securely to motor.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the blades. Measure this distance from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is positioned for measurement. Repeat for each blade. If all blade levels are not equal, you can adjust blade levels by the following procedure. To adjust a blade tip down, insert a washer (not supplied) between the blade and blade holder at the screw closest to the motor. To adjust a blade tip up, insert washer (not supplied) between the blade and blade holder at the two screws farthest from the motor. Reverse the position of the washer if blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.

If the above steps do not eliminate the wobble problem, you will need to dynamic balance your fan with balancing kit provided.

4. If light does not work: 1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulb and make sure bulb is tight in socket.

5.Remove light kit and check the plug connections if they are present.

6.If this fan uses remote controller, make sure dip switches are setting properly and make

CAUTION : Make sure main power is turned off before entering switch housing and/or canopy.

7

© 2018 Monte Carlo Fan Company 10/2018

Nov.2018

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement