Rust-Oleum EpoxyShield 263999, 264001 Specification

Rust-Oleum EpoxyShield 263999, 264001 Specification
TECHNICAL DATA
®
ESH-19
EPOXYSHIELD®
STAIN ADDITIVE FOR LOW VOC
PREMIUM CLEAR
DESCRIPTION AND USES
PRODUCT APPLICATION (CONT.)
EPOXYSHIELD® Stain Additive kit is designed to be mixed
with the EPOXYSHIELD® 263997 Low VOC Premium Clear
Floor Coating kit to create a high performance finish with a
professional look. The Low VOC Premium Clear Floor Coating is
a two-component epoxy coating designed to provide excellent
wear, impact, and abrasion resistance to heavy foot and vehicle
traffic. The Stain Additives are NOT stand alone coatings and
must be mixed with EPOXYSHIELD® 263997 Low VOC Premium
Clear Floor Coating kit.
For use in covered areas only. Not intended for carports or
areas exposed to direct sunlight. Prolonged exposure to direct
sunlight will cause the coating to fade with age. These changes
are cosmetic in nature only, and the performance of the coating
will not be affected.
For best results when using the Concrete Etch, the concrete should
be damp, but free of puddles. Mix the entire contents of the
Concrete Etch granules with 2 gallons (3.79 l) of water. Do not
add Concrete Etch directly to paint. Use a plastic sprinkling can
to evenly distribute the Concrete Etch solution. Scrub the floor
with a stiff bristle brush and make sure the floor stays wet during
this process until you are ready to rinse. Pay special attention
to the area where the vehicle tires normally stand. Continue to
scrub while rinsing to ensure all contaminates are washed away.
Squeegee off excessive water or puddles and allow to dry.
For best results, clean 10x10 foot (3x3 meters) sections at a time.
Completely wash, rinse, and squeegee each section before moving
on to the next. When all the sections have been completed in this
manner, then re-rinse and squeegee the entire floor. When the
floor is dry, rub your fingers on the concrete and check for a white
film. If a white dust or powder is detected, then repeat the rinsing
process being sure to thoroughly scrub during the rinse. Once
the concrete is free of surface residue, you are ready to begin
application of the coating. All pilot lights or open flames in the area
must be extinguished due to the flammability of the solvents in the
coating. Pilot lights or open flames must remain extinguished for a
minimum of 24 hours following application of the EPOXYSHIELD®
Premium Clear coating.
PREVIOUSLY COATED FLOORS:
Make sure the floor is clean and dry. The EPOXYSHIELD®
Low VOC Premium Clear coating is designed for use over
the EPOXYSHIELD® Garage Floor finish or EPOXYSHIELD®
Professional finish. The EPOXYSHIELD® Low VOC Premium Clear
coating can be applied over the Garage Floor finish after 24 hours.
The EPOXYSHIELD® Low VOC Premium Clear coating can be
applied over the Professional Floor finish between 16 hours and
5 days. For other previous coatings, use a wire brush to remove
any loose or peeling paint or stain. If floor is sealed, the sealer will
have to be removed by grinding or shot blasting. To ensure proper
adhesion, scuff sand the entire surface.
WARNING! If you scrape, sand or remove old paint, you may
release lead dust. LEAD IS TOXIC. EXPOSURE TO LEAD DUST CAN
CAUSE SERIOUS ILLNESS SUCH AS BRAIN DAMAGE, ESPECIALLY
IN CHILDREN. PREGNANT WOMEN SHOULD ALSO AVOID
EXPOSURE. Wear a NIOSH-approved respirator to control lead
exposure. Clean up carefully with a HEPA vacuum and a wet mop.
Before you start, find out how to protect yourself and your family
by contacting the National Lead Information Hotline at 1-800-424LEAD or log on to www.epa.gov/lead.
PRODUCTS
263999 Charcoal
264001 Rustic Brown
264006 Black Walnut
APPEARANCE
Semi-transparent finish.
PACKAGING INCLUDES
Stain Additive
Application Tools
Instructional DVD
Instructional Sheet
Concrete Etch
PRODUCT APPLICATION
SURFACE PREPARATION
Allow new concrete to cure for a minimum of 28 days. Check
the garage floor for conditions that might interfere with proper
adhesion (see directions sheet). Remove any oil spots or spills
and wash the floor with EPOXYSHIELD® Heavy Duty Degreaser
or a suitable detergent or degreasing solution. Thoroughly
rinse with fresh water. Then etch the floor using Rust-Oleum®
Concrete Etch.
1
Form: CS983
Rev.: 071712
TECHNICAL DATA
®
EPOXYSHIELD® STAIN ADDITIVE FOR LOW VOC PREMIUM CLEAR
PRODUCT APPLICATION (CONT.)
PRODUCT APPLICATION (CONT.)
MIXING
Before you activate the coating, prepare the roller cover. For
this project, use a 3/8” nap roller cover. First insert the roller
cover into the plastic bag provided with the kit. Secure the
bottom of the bag to the roller cover with a rubber band.
While holding the roller cover in one hand, with the other
hand slightly twist the plastic bag around the roller cover. Use
another rubber band to secure the other end of the bag. Use a
third rubber band to secure the center of the bag to the roller
cover. None of the rubber bands should be secured too tightly,
twisting over only 2 or 3 times. If the bag is too tight, the
creases on the roller cover will be visible on the floor. Finally,
tuck the remaining part of the bag into the open end of the
roller cover and while holding the roller cover to keep the bag
from tightening, insert the roller frame.
Pour the entire stain additive (Part C) into the base (Part B) and
stir thoroughly for 2 minutes. To activate the mixture, pour the
entire activator (Part A) into the mixture and stir thoroughly
for 2 minutes. If using the anti-slip additive (recommended), it
should be added slowly and thoroughly mixed at this time. The
activated coating must be used within 90 minutes after mixing.
APPLICATION
Apply only when air, material, and surface temperatures are
between 60-85ºF (15-29ºC) and the surface temperature
is at least 5ºF (3ºC) above the dew point. The relative
humidity should not be greater than 85%. The minimum floor
temperature for painting is 55°F (13°C). Apply in the midafternoon or later when temperatures are declining and the
surface to be coated is not in direct sunlight. Pour a portion
of the admixed material into a lined paint pan. Immediately
begin to cut in the perimeter of the floor along the wall, or
other areas where a roller cannot reach, using a brush or
edger before beginning roller application. Use the prepared
3/8” nap roller cover on a 9” roller frame to apply an even coat
of EPOXYSHIELD® Low VOC Premium Clear Coating onto the
surface. Limit the application to 4x4 foot (1.2x1.2m) sections
at a time. Maintain a wet edge to prevent lap marks and gloss
variations. Make all final passes in the same direction to ensure
uniform appearance. If using the anti-slip additive, continue to
stir the admixed material periodically to ensure additive does
not settle in the pan. Only one coat is necessary under most
circumstances. EPOXYSHIELD® Low VOC Premium Clear must
be used within 90 minutes following initial mixing to ensure
even gloss.
CLEAN-UP
When finished, wash tools and equipment with xylene or
acetone. Clean up drips or spatters IMMEDIATELY with xylene
or acetone as dried paint is very difficult to remove. Properly
dispose of all soiled rags.
2
Form: CS983
Rev.: 071712
TECHNICAL DATA
®
EPOXYSHIELD® STAIN ADDITIVE FOR LOW VOC PREMIUM CLEAR
PHYSICAL PROPERTIES
STAIN ADDITIVE KIT
Resin Type
Amine cured epoxy
Solvents
Weight*
Solids*
Methyl Acetate
Per Gallon
9.1-9.4 lbs.
Per Liter
1.09-1.13 kg
By Weight
71.4-82.3%
By Volume
72.2-79.5%
Volatile Organic Compounds*
<50g/l (0.42 lbs/gal)
Mixing Ratio
8 oz. stain additive per 120 oz. clear base
Recommended Dry Film
Thickness (DFT) Per Coat
2.0-5.0 mils (50-125µ)
Wet Film to Achieve DFT
(Unthinned Material)
3.0-7.0 mils (75-175µ)
Theoretical Coverage at
1 mil DFT (25µ)
1158-1275 sq.ft./gal
(28.0-31.0 m2/l)
500 sq.ft./gal. (23 m2/l) painted surfaces
250 sq.ft./gal. (46 m2/l) bare concrete
Practical Coverage at Recommended
DFT (assumes 15% material loss)
Induction Period
None
Pot Life @ 70-80°F (21-27°C)
and 50% Rel. Hum.
Dry Times
at 70-80°F
(21-27°C) and
50% Rel. Hum.
90 minutes
Lt. Foot Traffic
10 hours
Hv. Foot Traffic
24 hours
Vehicle Traffic
4 days
Shelf Life
Safety
Information
2 years
Flash Point
32ºF (0ºC)
Safety
FOR ADDITIONAL INFORMATION, SEE MSDS.
Calculated values may vary slightly from the actual manufactured material.
*Activated material.
The technical data and suggestions for use contained herein are correct to the best of our knowledge, and offered in good faith. The statements of this literature do not constitute
a warranty, express, or implied, as to the performance of these products. As conditions and use of our materials are beyond our control, we can guarantee these products only
to conform to our standards of quality, and our liability, if any, will be limited to replacement of defective materials. All technical information is subject to change without notice.
Rust-Oleum Corporation
11 Hawthorn Parkway
Vernon Hills, Illinois 60061
An RPM Company
Phone: 877• 385•8155
www.rustoleum.com/industrial
Form: CS983
Rev.: 071712
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement