RIDGID RWCS50T 1/2 HP 120-Volt Sewage Pump Instructions

Add to my manuals
10 Pages

advertisement

RIDGID RWCS50T 1/2 HP 120-Volt Sewage Pump Instructions | Manualzz

Sewage Pumps

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Operating Instructions and Parts Manual RWCS50T

SPECIFICATIONS

POWER SUPPLY

REQUIREMENTS 120 V, 60 Hz

MOTOR

HORSEPOWER

LIQUID TEMPERATURE

CIRCUIT REQUIREMENTS

Single Phase, Dielectric Oil Filled

1/2 HP

40° F - 120° F

15 A (minimum)

DIMENSIONS 16-5/8 in. high x 9-5/8 in. base

ON LEVEL (FACTORY SET) Approximately 19 in.

OFF LEVEL (FACTORY SET) Approximately 10.5 in.

CONSTRUCTION

MOTOR HOUSING

VOLUTE

Cast Iron

Cast Iron

IMPELLER Glass Reinforced Thermoplastic

SHAFT

DISCHARGE

Steel

2 in. NPT

Model

RWCS50T

PERFORMANCE (Gal/hr)

HP

Discharge Head (Lift Distance)

0 ft 5 ft 10 ft 15 ft

1/2 10000 9900 8100 3600

© 2019, RIDGID TOOL COMPANY

Intended for Indoor Use Only

610001W-005 C 09/19

INSTALLATION MANUAL

SEWAGE PUMP DESCRIPTION

Sewage pumps are pumps used to remove waste water that contains solids up to 2 inches in diameter. The most common application is for draining bathroom waste water to a sewer or septic line.

Intended for indoor use only. Installation of this pump outdoors, unprotected from the weather, may cause hazardous conditions and will void warranty. If using outdoors, protect pump from direct weather elements such as sun, rain, sleet, snow, and extreme temperature changes. Water inside the pump may freeze, limiting its performance and damaging the pump and pipes.

UNPACKING

Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement, or call Customer Support (800-237-0987).

SAFETY SIGNAL WORDS

This manual contains information that is very important to know and understand. This information is provided for

SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe all safety information labeled danger, warning, caution, and notice.

IMPORTANT SAFETY INFORMATION

CONSIGNES DE SÉCURITÉ

IMPORTANTES

WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION

WHICH, IF NOT AVOIDED, COULD RESULT IN DEATH OR

SERIOUS INJURY.

LA MENTION AVERTISSEMENT INDIQUE UNE SITUATION

POTENTIELLEMENT DANGEREUSE QUI, SI ELLE N’EST PAS

ÉVITÉE, RISQUE D’ENTRAÎNER DES LÉSIONS CORPORELLES

GRAVES OU MÊME LA MORT.

RISK OF ELECTRIC SHOCK. TO REDUCE THIS RISK,

OBSERVE THE FOLLOWING WARNINGS:

RISQUE DE CHOC ÉLECTRIQUE. POUR RÉDUIRE CE

RISQUE, TENIR COMPTE DES AVERTISSEMENTS

SUIVANTS

MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE

AVAILABLE. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.

S’ASSURER QU’UNE PRISE DE MISE À LA TERRE EST DISPONIBLE.

Cette pompe est fournie avec un conducteur et une fiche de mise à la terre. Pour réduire le risque de choc électrique, s’assurer qu’elle est branchée seulement à une prise de courant correctement mise

à la terre.

FOR ADDED SAFETY the receptacle must be protected with a ground fault circuit interrupter (GFCI). All wiring must be performed by a qualified licensed electrician and comply with the National Electric

Code and all applicable local codes and ordinances.

POUR PLUS DE SÉCURITÉ, la prise de courant doit être protégée par un disjoncteur de fuite à la terre. Tout le câblage doit être effectué par un électricien qualifié et être conforme au Code électrique national et à tous les codes et règlements locaux applicables.

NEVER REMOVE THE GROUND PRONG from the plug or bypass the grounding wires.

NE JAMAIS RETIRER LE CONNECTEUR DE MISE À LA TERRE de la prise ou contourner les fils de mise à la terre.

MAKE SURE THE POWER SUPPLY HAS A FUSE OR CIRCUIT BREAKER rated to handle the current (amps) noted on the pump nameplate or cord tag.

S’ASSURER QUE L’ALIMENTATION ÉLECTRIQUE EST MUNIE D’UN

FUSIBLE OU D’UN DISJONCTEUR d’une valeur nominale appropriée pour supporter l’intensité du courant (ampérage) indiquée sur la plaque signalétique ou l’étiquette du cordon de la pompe.

2

Intended for Indoor Use Only

INSTALLATION MANUAL

ALWAYS DISCONNECT THE PUMP from power supply before installing, servicing or making any adjustments.

TOUJOURS METTRE LA POMPE HORS TENSION avant de procéder à l’installation, à l’entretien ou à des réglages.

DO NOT WALK on the floor when water is present until all power is turned off. If the electric panel is in the basement, call an electrician.

NE PAS MARCHER sur un sol mouillé avant que l’alimentation générale ne soit coupée. Si le tableau électrique est en sous-sol, appeler un électricien.

NEVER HANDLE A PUMP or motor with wet hands or when standing on a wet or damp floor while the pump is plugged into the power supply.

NE JAMAIS MANIPULER UNE POMPE ou un moteur de pompe avec les mains mouillées ou debout dans l’eau ou sur une surface humide.

RISK OF ELECTRIC SHOCK. This pump has not been investigated for use in swimming pool and marine areas.

RISQUE DE CHOC ÉLECTRIQUE. Cette pompe n’a pas fait l’objet de vérification pour une utilisation dans les piscines et les aires marines.

DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Pump should only be used to pump clear water. Personal injury and/or property damage will result and void warranty.

NE PAS UTILISER POUR POMPER DES FLUIDES INFLAMMABLES OU

EXPLOSIFS tels que l’essence, le mazout, le kérosène, etc. Ne pas utiliser dans un environnement inflammable et/ou explosif.

La pompe ne doit être utilisée que pour pomper de l’eau claire.

Des blessures corporelles et/ou des dégâts matériels pourraient en résulter.

PUMPS ARE NOT DESIGNED TO TRANSFER WATER INTENDED FOR

DRINKING. Do not use the pump for moving water that will be used for potable/drinking water. Pump should only be used in applications for which it is designed.

LES POMPES NE SONT PAS CONÇUES POUR L’ACHEMINEMENT

D’EAU DESTINÉE À LA CONSOMMATION. Ne pas utiliser la pompe pour transporter de l’eau qui sera utilisée comme de l’eau potable/destinée à la consommation. La pompe doit être utilisée uniquement dans les applications pour lesquelles elle est conçue.

DO NOT USE AN EXTENSION CORD OR SURGE PROTECTOR. Extension cords and/or surge protectors could present a safety hazard if not sized properly, become damaged or the connection falls into the sump. If receptacle is not within reach of the pump’s power cord, contact a qualified licensed electrician to install a new receptacle.

NE PAS UTILISER DE RALLONGE NI DE PROTECTEUR DE SURTENSION.

Les rallonges et/ou les protecteurs de surtension peuvent présenter un danger pour la sécurité s’ils ne sont pas correctement calibrés, s’ils sont endommagés ou si le raccordement tombe dans le puisard. Si la prise n’est pas à portée du cordon d’alimentation de la pompe, contacter un électricien qualifié pour installer une nouvelle prise.

CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION

WHICH, IF NOT AVOIDED, MAY RESULT IN MINOR OR

MODERATE INJURY.

MISE EN GARDE

LA MENTION MISE EN GARDE INDIQUE UNE SITUATION

POTENTIELLEMENT DANGEREUSE QUI, SI ELLE N’EST PAS

ÉVITÉE, POURRAIT ENTRAÎNER DES BLESSURES MINEURES

OU MODÉRÉES.

TO REDUCE THE RISK OF HAZARDS THAT CAN CAUSE

INJURY OR PROPERTY DAMAGE, OBSERVE THE FOLLOWING

WARNINGS:

POUR RÉDUIRE LE RISQUE DE DANGERS POUVANT CAUSER

DES BLESSURES OU DES DÉGÂTS MATÉRIELS, RESPECTER

LES MISES EN GARDE SUIVANTES :

IT IS THE INSTALLER’S RESPONSIBILITY TO MAKE SURE THE

PUMPS AUTOMATIC SWITCH IS ABLE TO OPERATE WITHOUT ANY

OBSTRUCTIONS WITHIN THE BASIN. It is recommended that the installer test and observe the pump’s operation for several cycles after installation.

IL EST DE LA RESPONSABILITÉ DE L’INSTALLATEUR DE S’ASSURER QUE

L’INTERRUPTEUR AUTOMATIQUE DE POMPE PEUT FONCTIONNER SANS

AUCUN BLOCAGE À L’INTÉRIEUR DU SYSTÈME. Il est recommandé que l’installateur teste et observe le fonctionnement de la pompe pendant plusieurs cycles après l’installation.

3

INSTALLATION MANUAL

IT IS REQUIRED TO USE RIGID PIPING AND FITTINGS to secure the pump in the basin and reduce pump movement. Pump movement can prevent the switch from operating correctly. Do not use flexible hosing.

IL EST NÉCESSAIRE D’UTILISER DES TUYAUX ET DES RACCORDS

RIGIDES pour fixer la pompe dans le système et réduire les mouvements de la pompe. Les mouvements de la pompe peuvent empêcher l’interrupteur de fonctionner correctement. Ne pas utiliser de tuyaux flexibles.

IT IS REQUIRED TO USE A CHECK VALVE with this pump to prevent the back-flow of water after each pump cycle.

Cette pompe NÉCESSITE L’UTILISATION D’UNE VANNE DE CONTRÔLE pour empêcher le reflux d’eau souterraine claire après chaque cycle de pompage.

DO NOT INSTALL OR OPERATE THE PUMP IF IT HAS BEEN DAMAGED

IN ANY WAY.

NE PAS INSTALLER OU FAIRE FONCTIONNER LA POMPE SI ELLE A ÉTÉ

ENDOMMAGÉE DE QUELQUE MANIÈRE QUE CE SOIT.

DO NOT LIFT OR CARRY THE PUMP BY THE POWER CORD. Use the pump’s handle or lift ring.

NE PAS SOULEVER OU PORTER LA POMPE PAR LE CORDON

D’ALIMENTATION. Utiliser la poignée ou la bague de levage de la pompe.

AN INDEPENDENT HIGH WATER ALARM OR BACK UP PUMP SHOULD BE

USED when risk of property damage from high water levels exists.

UNE ALARME AUTONOME DE? NIVEAU D’EAU ÉLEVÉ OU UNE POMPE DE

SAUVEGARDE DOIVENT ÊTRE UTILISÉES en cas de risque de dégâts matériels causés par des niveaux d’eau élevés.

REPLACE THE TETHER SWTICH EVERY TWO (2) YEARS. This required maintenance will reduce the risk of improper pump operation, switch failure and/or flooding.

REMPLACER LE COMMUTATEUR TOUS LES DEUX (2) ANS. Cet entretien réduira le risque d’utilisation incorrecte de la pompe, de défaillance de l’interrupteur ou d’inondation.

This product can expose you to chemicals, including DEHP, which is known to the State of California to cause cancer, birth defects and reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Ce produit peut vous exposer à des produits chimiques, notamment du DOP, reconnus par l’État de Californie comme

étant cancérigènes et à l’origine d’anomalies congénitales et de problèmes de l’appareil reproductif. Pour plus de renseignements, visiter le site www.P65Warnings.ca.gov.

TETHER FLOAT SWTICH This float should not be adjusted. Changing the length of the tether switch will effect on and off water levels, run time, and may result in the pump running continuously.

L’INTERRUPTEUR DU FLOTTEUR À AMARRE Ce flotteur ne devrait pas

être ajusté. Si vous modifiez la longueur de l’interrupteur d’attache, les niveaux d’eau et la durée de fonctionnement seront activés et désactivés. La pompe pourrait fonctionner en permanence.

4

TYPICAL SEWAGE INSTALLATION

1. This installation must be in accordance with the National

Electric Code and all applicable local codes and ordinances.

2. Use a basin (5) that is large enough to accommodate the pump. The basin diameter should be a minimum of 18 inches and the depth a minimum of 24 inches.

3. Clean the basin of all debris.

4. Set the pump (6) on a solid, level surface. Do not place pump directly on clay, earth, gravel, or sand. A brick or block may be installed under the pump to provide a solid base.

5. Position pump (6) in the basin (5) so the tether switch (7) is away from incoming water. Verify the tether float switch has at least 1 inch clearance to the side wall of the basin and is free of any possible obstructions.

6. Install discharge plumbing according to local, regional and state codes. Do not reduce the discharge pipe (3) size below that which is provided on the pump (6).

7. A union (2) should be installed above the basin to allow easy removal of the pump (6) for cleaning and service.

8. Install a check valve (1) (required) to prevent back-flow.

It should be installed above the union.

9. A gate valve or ball valve should be installed above the check valve if required by local, regional or state codes.

10. Connect remaining discharge pipe. Keep sections as short as possible with a minimum number of turns.

11. A vent pipe (11) is required. It removes gases and odors and should be installed as required by local, regional or state codes.

12. Secure power supply cord (8) to discharge pipe (3) using cable or zip ties to prevent possible switch entanglement.

13. Connect tether switch (7) piggyback cord to a ground fault circuit interrupter (GFCI) outlet (9) (required) then connect the pump power supply cord (8) into the piggyback cord.

14. Fill the basin with water. The pump will start when the water level has reached the switch-on level. Verify the pump is operating normally.

15. Install a basin cover and gasket (10) to prevent debris from falling into the basin, prevent personal injury, and to contain gases and odors.

1. Check Valve

2. Union

3. Discharge Pipe

4. Inlet Pipe

5. Basin

6. Pump

INSTALLATION MANUAL

7. Tether Switch

8. GFCI Outlet

9. Piggyback Plug

10. Pump Power Supply Cord

11. Vent Pipe

12. Gasket/Basin Lid

5

INSTALLATION MANUAL

TROUBLESHOOTING WARNINGS

ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY before installing or servicing.

TOUJOURS METTRE LA POMPE HORS TENSION avant de procéder à l’installation, à l’entretien.

1. Submersible pump models have permanently lubricated bearings and require no additional lubrication.

2. Submersible pumps contain dielectric oil for cooling.

Dielectric oil can be harmful to the environment. Follow state environmental laws when disposing of oil.

3. The pump motor is equipped with automatic resetting thermal protector and may restart unexpectedly. Protector tripping is an indication of motor overloading as a result of operating the pump at low heads, excessively high or low voltage, inadequate wiring, incorrect motor conditions, or that the motor is at the end of its product life.

LET PUMP COOL FOR A MINIMUM OF 2 HOURS BEFORE ATTEMPTING TO

SERVICE. Submersible pumps contain oil may become pressurized and hot under normal operating conditions.

LAISSER REFROIDIR LA POMPE PENDANT AU MOINS 2 HEURES AVANT

D’ESSAYER DE LA RÉPARER. Les pompes submersibles contiennent de l’huile qui devient pressurisée et chaude dans des conditions normales de fonctionnement.

TROUBLESHOOTING

Symptoms

Pump will not start or run

Pump starts and stops too often

Possible Cause(s)

1. Water level too low

2. Blown fuse or tripped circuit breaker

3. Low supply voltage

4. Motor

5. Switch

6. Inlet clogged

7. Switch obstruction

8. GFCI

1. Back-flow of water from discharge pipe

2. Switch

3. Check valve not functioning properly or leaking

Suggested Remedies

1. Water must be at the appropriate level to activate switch

2. If blown, determine cause and then either replace with proper sized fuse or reset breaker

3. Contact an electrician

4. Replace pump

5. Replace switch

6. Remove debris

7. Remove obstruction to verify free motion of switch

8. Reset GFCI outlet

1. Install check valve

2. Replace switch

3. Remove and examine check valve for prop er in stal la tion and free operation. Replace check valve if necessary.

Pump shuts off and turns on independently of switch (trips thermal overload protection)

1. Switch

2. Switch obstruction

3. Obstruction in discharge pipe

4. Low supply voltage

1. Replace tether switch

2. Remove obstruction to verify free motion of switch

3. Remove obstruction in discharge piping

4. Contact an electrician.

6

INSTALLATION MANUAL

TROUBLESHOOTING

(CONTINUED)

Symptoms Possible Cause(s) Suggested Remedies

Pump operates noisily or vibrates excessively

1. Worn bearings

2. Impeller broken

3. Piping attachments to building structure too rigid or too loose

Pump will not shut off

Pump operates but delivers little or no water

Pump trips GFCI

1. Switch

2. Switch obstructions

3. Restricted discharge (obstruction in piping)

4. Excessive inflow or pump not properly sized for application

1. Low supply voltage

2. Inlet clogged

3. Broken impeller

4. Pump not properly sized for application

5. Check valve stuck closed or installed backwards

6. Shut off valve closed

1. Bad GFCI

2. Bad pump

1. Replace pump

2. Replace pump

3. Install rubber coupling (available at local hardware stores) to isolate pump vibration from discharge plumbing

1. Replace switch

INSTALLATION MANUAL

3. Remove obstruction from discharge piping

4. Recheck all sizing calculations to determine proper pump size

1. Contact an electrician

2. Remove debris

3. Replace pump

4. Recheck all sizing calculations to determine proper pump size

5. Remove and examine check valve for proper installation and free operation

6. Open valve

1. Contact an electrician to verify GFCI operation

2. Replace pump

ROUTINE MAINTENANCE

The pump should be inspected monthly for pump movement or buildup of debris on the switch or float Reposition pump if it has moved. Remove any debris that could interfere with the operation of the switch. Lack of proper routine maintenance will void warranty.

• Make sure the pump is plugged in to a working ground fault circuit interrupter (GFCI) outlet and the cord is in good shape. In damp areas, GFCI breakers may trip, effectively shutting off the pump. Check in on your sewage pump and reset the GFCI if necessary.

• Ensure the pump is standing upright. Vibrations during operation can cause it to move or tilt onto one side. This can jam the tether float so it can’t activate the pump.

• Flush toilet or run sink to make sure the pump starts automatically and the water drains quickly once the pump is on. If the pump doesn’t start, have it serviced or replaced.

• Replace the tether switch every two (2) years. This maintence will reduce the risk of improper pump operation, switch failure and/or flooding.

7

WARRANTY & SERVICE PARTS SHEET - REPLACEMENT PARTS

2

REF. NO.

1

2

MODEL:

DESCRIPTION

TETHER SWITCH

10 FT. POWER CORD

REPAIR KITS

ALL MODELS

PART NUMBER

56835-WYN1

31006-WYN2

8

9

FOR REPLACEMENT

PARTS OR CUSTOMER SUPPORT,

CALL 1-877-9RIDGID

Please provide following information:

- Model number

- Serial number on cord tag (not to be removed)

- Part description and number as shown in parts list

INSTALLATION MANUAL

ADDRESS PARTS CORRESPONDENCE TO:

RIDGID Water Systems

101 Production Drive

Harrison, OH 45030 U.S.A.

Thank you for making RIDGID Pumps s a key part of your home maintenance program. If properly installed, maintained and operated in accordance with RIDGID Water Systems’ written instructions, your pump should provide you with approximately

( * ) years of service.

Product Warranty ( * ) Expected Life

3

5

1

2

6

6

3

3

LIMITED WARRANTY

For three years for RWCS50T model from the date of purchase, from an authorized dealer, RIDGID Water Systems will repair or replace, at its option for the original purchaser, any part or parts of its Sewage or Effluent Pumps or Water Pumps (“Product”) found upon examination by RIDGID Water Systems to be defective in materials or workmanship. Please call RIDGID Water Systems (1-877-9RIDGID) for warranty instructions. Be prepared to provide the model number and the serial number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. This Limited

Warranty is not transferrable.This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with RIDGID’s written instructions.

This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with RIDGID Water Systems’ written instructions.

THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, OBLIGATIONS OR AGREEMENTS, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED

WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE

UNIFORM COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT. THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY

ARE THE SOLE AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY WAY

CONNECTED WITH THE PRODUCT, REGARDLESS OF THE SOURCE OR PROVIDER OF SUCH GOODS. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT,

WARRANTY TORT (INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL RIDGID WATER SYSTEMS OR ANY AFFILIATE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR

CONSEQUENTIAL DAMAGES.

You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call RIDGID Water Systems (1-877-9RIDGID) for return authorization and instructions.

DO NOT MAIL THIS FORM TO RIDGID Water Systems.

Use this form only to maintain your records.

MODEL NO._____________________ SERIAL NO._________________________ INSTALLATION DATE __________________________

ATTACH YOUR RECEIPT HERE

NOTES

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

_____________________________________________________________________________________________

10

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement