Handy Home Products 18806-0 10 ft. Reverse Gable Kit-DISCONTINUED Instructions

Handy Home Products 18806-0 10 ft. Reverse Gable Kit-DISCONTINUED Instructions
10’ REVERSE GABLE
For 10’ Wide Gable Buildings
Made in the U.S.A
Part I.D.
1
GPL
GPR
EGL
EGR
EEL
EER
UB
EE
A
B
1-1/4"
(3.2cm)
EE
1-1/2"
(3.8cm)
1" (2.5cm) Screws
Qty.
1
1
1
1
1
1
1
1
2
2
Description
Size
Gable End Panel Left
Gable End Panel Right
Gable Trim Left
Gable Trim Right
Horizontal Gable Trim Left
Horizontal Gable Trim Right
Ridgeboard
Gable Connector
Large Roof Panel
Small Roof Panel
3/8” x 22-11/16” x 33-13/16”
3/8” x 22-11/16” x 33-13/16”
1” x 2-1/2” x 38-11/16”
1” x 2-1/2” x 38-11/16”
1” x 2-1/4” x 35-1/2”
1” x 2-1/4” x 35-1/2”
2” x 4” x 54-7/8”
1” x 3” x 17-7/8”
7/16” x 25” x 23-7/8” x 42-3/4”
7/16” x 25” x 33-11/16”
GPR
1.
Place EE under one Gable end panel with
Primer side up as shown keeping 1-1/4” in
from edge and up 1-1/2” from bottom.
Connect with two 1” screws through
Panels into EE. Butt second Gable End
up to first Gable End and attach in the
same manner.
2.
Position connected Gable Ends flush to top
of Ridge Board UB. Connect with four 1-1/
2” nails through Panels into Ridge Board.
3.
Position all trim parts on flat surface as
shown, keeping EGL and EGR Gable trim
flush at peak and to Horizontal Gable trim
EEL and EER. Center assembled Gable
panels on top of trim as shown and secure
with 1” screws through Gable panels into
Trim as shown. Trim will overhang bottom
as shown.
1" (2.5cm) Screws
GPL
03/29/2007
#16611
1-1/2"
(3.8cm)
Side View of Assembly
2
Gable End
1-1/2"
(3.8cm)
Nails
EER
3
EEL
EGR
UB
EGL
EEL
(12)-1"(2.5cm)
Screws
EGL
Sideview
UNDERSIDE VIEW
A
4.
Position Large Roof Panel flush at Peak and
Front Trim. Secure with four 1-1/2” nails into
Trim EGL and with two 1-1/2” nails into the
Ridge Board UB use nail pattern as shown.
5.
1-1/2"
(3.8cm)
Nails
Position second Large Roof Panel flush to first
Panel and Trim. Secure with four 1-1/2” nails
into Trim EGR and with two 1-1/2” nails into
Ridge Board UB use nail pattern as shown.
6.
Position Gable Assembly on building Roof
(usually centered over Door opening). Note:
Starter row of shingles should be applied
first. Secure Gable Assembly to Roof with
(8) 1-1/2” nails (four per side) through
Reverse Gable Roof Panels into building Roof
as shown.
7.
Place one H-Clip centered on the unattached
edge of the Left Large Roof Panel. Position
the same size side of Small Roof Panel as
rear of large panel into H-Clip. Align Small
Roof Panel flush with Large Roof Panel at
Ridge Board. Secure with (5) 1-1/2” nails,
three into Roof Panels and two into Ridge
Board, as shown.
5
4
38-1/8"
(97 cm)
Paint bottom edge
before installing
Small
Panel
7
Same
Size
1-1/2" nails
(3.8cm)
"H" Clip
B
6
Continue with opposite side in same fashion.
Finish Gable Ends and Trim using two coats
of Exterior Grade Acrylic Latex Paint.
Note: Follow shingle manufacture
recommendations for valley installation of
shingles.
Note: Starter row of shingles
h ld b
li d fi t
8
9
8-9. If building is not shingled, shingle building
roof first. Follow all manufacturers
instructions for shingling. Overlap reverse
gable by 6” or more as shown in figure 8.
If a shingle does not run up gable by 6”
cut tab off and run a full shingle up gable.
Once building roof is completed then
shingle reverse gable as shown in figure
9. Run reverse gable shingles all the way
to the valley where the roofs meet. Cut
the shingles on the reverse gable back by
2”.