MOTION

GUIDE

MOTION DETECTOR SENSOR

1] learn it in

Remove screw on bottom of

Sensor and remove backplate

Access the Home Screen on your tattletale Consumer Unit.

1] press Settings

2] enter Primary PIN

3] press Advanced

4] press Sensors

5] press Add Sensor

It will ask for your sensor to be placed in “learn mode”.

6] Press and hold on

tamper switch note: The Consumer Unit will sound to indicate sensor has been learned in successfully

2] set it up

[ Tamper Switch ]

Walk Test

Place supplied magnet over arrow on left side of sensor, then remove (LED light indicates detection)

Walk out coverage area making sure the LED flashes for every movement. Test lasts for 1 minute

NOTE: allow a 3 second delay between flashes.

Sensor is set to Interior Delay by default.

[

1] set Name: setting a specific name & location seperates sensors

2] set Type: instant or delay use instant only if sensor will not be tripped during

Entry/Exit to disarm system while in Away mode

]

3] allow Bypass: determines whether it can be bypassed during arming cycle

3] mount it

Standard Corner or Wall Mounting.

[

Refer to Figures on right for bracket mounting

]

1] avoid these Locations: direct sunlight, rapid temperature change, air ducts, metal wall

2] Corner Mounting:

Sensor can be mounted on

Remove Backplate from

Sensor. Use either 2 upper or

2 lower screw holes. Mount height at 7.5 ft. Attach

Sensor on Backplate

3] Wall Mounting: corner or wall, or ceiling using supplied brackets

Remove Backplate. Use 2 screw holes in center. Mount height at 7.5 ft. Attach

Sensor on Backplate

1 ]

2 ]

3 ]

4 ]

5 ]

Screw part A to part B using small screw.

part B insert

Select either the

Corner Mount [ D ] or

Wall Mount [ C ].

Mount selected bracket at a height of

7.5 ft. on the wall using supplied long screws with anchors.

Place the assembly of parts A and B on the shaft of the desired mounting bracket.

[ A ]

Backplate

[ B ]

Mounting Bracket

Wall Mount

Screw Holes

Place on part D or E’s

Mounting Shaft

Insert screw on top of shaft to hold bracket in place.

[ see figure to right ]

6 ]

Attach the sensor to mounted backplate with the screw at the bottom to secure.

[ C ]

Wall Mount

NOTE:

After the Sensor trips (sensing motion) it will not trip again for 3 minutes

During normal operation, the LED will never illuminate. The LED only illuminates in test mode

[ D ]

Corner Mount

Corner

Mount

Screw

Holes backplate insert screw here backplate insert

Screw on top of part C or D after part B has been inserted on top

MOTION DETECTOR SENSOR

1] learn it in

Remove screw on bottom of

Sensor and remove backplate

Access the Home Screen on your tattletale Consumer Unit.

1] press Settings

2] enter Primary PIN

3] press Advanced

4] press Sensors

5] press Add Sensor

It will ask for your sensor to be placed in “learn mode”.

6] Press and hold on

tamper switch note: The Consumer Unit will sound to indicate sensor has been learned in successfully

2] set it up

[ Tamper Switch ]

Walk Test

Place supplied magnet over arrow on left side of sensor, then remove (LED light indicates detection)

Walk out coverage area making sure the LED flashes for every movement. Test lasts for 1 minute

NOTE: allow a 3 second delay between flashes.

Sensor is set to Interior Delay by default.

[

1] set Name: setting a specific name & location seperates sensors

2] set Type: instant or delay use instant only if sensor will not be tripped during

Entry/Exit to disarm system while in Away mode

]

3] allow Bypass: determines whether it can be bypassed during arming cycle

3] mount it

Standard Corner or Wall Mounting.

[

Refer to Figures on right for bracket mounting

]

1] avoid these Locations: direct sunlight, rapid temperature change, air ducts, metal wall

2] Corner Mounting:

Sensor can be mounted on

Remove Backplate from

Sensor. Use either 2 upper or

2 lower screw holes. Mount height at 7.5 ft. Attach

Sensor on Backplate

3] Wall Mounting: corner or wall, or ceiling using supplied brackets

Remove Backplate. Use 2 screw holes in center. Mount height at 7.5 ft. Attach

Sensor on Backplate

1 ]

2 ]

3 ]

4 ]

5 ]

Screw part A to part B using small screw.

part B insert

Select either the

Corner Mount [ D ] or

Wall Mount [ C ].

Mount selected bracket at a height of

7.5 ft. on the wall using supplied long screws with anchors.

Place the assembly of parts A and B on the shaft of the desired mounting bracket.

[ A ]

Backplate

[ B ]

Mounting Bracket

Wall Mount

Screw Holes

Place on part D or E’s

Mounting Shaft

Insert screw on top of shaft to hold bracket in place.

[ see figure to right ]

6 ]

Attach the sensor to mounted backplate with the screw at the bottom to secure.

[ C ]

Wall Mount

NOTE:

After the Sensor trips (sensing motion) it will not trip again for 3 minutes

During normal operation, the LED will never illuminate. The LED only illuminates in test mode

[ D ]

Corner Mount

Corner

Mount

Screw

Holes backplate insert screw here backplate insert

Screw on top of part C or D after part B has been inserted on top

www.tattletale.com

6269 Frost Road. Westerville OH 43082

MOTION

GUIDE

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement