ProCom Heating PCS150T Ventless Fireplace Insert Thermostat Control Arched Door -15,000 BTU Manual
Add to my manuals32 Pages
advertisement
▼
Scroll to page 2
of 32
VENT-FREE GAS FIREPLACE INSERT OWNER’S OPERATION AND INSTALLATION MANUAL MODELS PCS100T AND PCS150T PFS ® US WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the v icinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency or the gas supplier. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-866-573-0674, 7:30 am - 4:15 pm CST, Monday through Friday or email [email protected] TABLE OF CONTENTS Safety......................................................... 3 Qualified Installing Agency......................... 4 Specifications............................................. 5 Product Features........................................ 5 Local Codes............................................... 5 Unpacking.................................................. 6 Product Identification.................................. 6 Water Vapor: A By-Product Of Unvented Room Heaters...................... 6 Air For Combustion and Ventilation............ 7 Installation.................................................. 9 Operation.................................................. 17 Inspecting Burners................................... 20 Care And Maintenance............................. 21 Troubleshooting........................................ 23 Replacement Parts................................... 27 Accessories.............................................. 27 Service Hints............................................ 27 Technical Service..................................... 27 Parts......................................................... 28 Warranty................................................... 32 SAVE THIS BOOK This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air For Combustion and Ventilation section on page 6 of this manual. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier. This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with propane or natural gas. This appliance is equipped with a simple means to switch between propane and natural gas. Field conversion by any other means including the use of a kit is not permitted. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. 2 www.usaprocom.com 200159-01A SAFETY IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning. Failure to follow these instructions will void the warranty. Only a qualified installer, service agent, or local gas supplier may install and service this product. WARNING: Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. WARNING: This appliance can be used with propane or natural gas. It is shipped from the factory adjusted for use with propane. DANGER: Carbon monoxide poisoning may lead to death! CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes. NATURAL AND PROPANE/LP GAS: Natural and Propane/LP gas are odorless. An odormaking agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. WARNING: Any change to this heater or its controls can be dangerous. 200159-01A WARNING: Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces. WARNING: Do not allow fans to blow directly into fireplace. Avoid any drafts that alter burner flame patterns. WARNING: Do not use a blower insert, heat exchange insert or other accessory not approved for use with this heater. WARNING: Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. WARNING: Clothing or other flammable material should not be placed on or near the appliance. Never place any objects in the heater. WARNING: Heater becomes very hot when running. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. www.usaprocom.com 3 SAFETY WARNING: You must operate this heater with screen in place. Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance. 1. Do not place Propane/LP supply tank(s) inside any structure. Propane/LP supply tank(s) must be placed outdoors. 2. Model PCS100T This heater shall not be installed in a bathroom. Model PCS150T This heater shall not be installed in a bedroom or bathroom. 3. This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 7 and 8. If heater keeps shutting off, see Troubleshooting, page 23. 4. Keep all air openings in front and bottom of heater clear and free of debris. This will ensure enough air for proper combustion. 5. If heater shuts off, do not relight until you have provided fresh, outside air. If heater keeps shutting off, have it serviced. 6. Do not run heater: • Where flammable liquids or vapors are used or stored. • Under dusty conditions. 7. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 8. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 9. Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater. 10. Operating heater above elevations of 4,500 feet could cause pilot outage. 11. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity. 12. Do not use this heater as a wood-burning heater. Use only the logs provided with the heater. 13. Do not operate heater if any log is broken. Do not operate heater if any log is chipped (dime-sized or larger). 14. To prevent sooting, follow the instructions in Care and Maintenance (see page 21). 15. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of heater. After servicing, always replace screen before operating heater. 16. This heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and the heater burning manufacturing residues. QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping, gas utilization equipment or accessories, and repair and equipment servicing. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for: 4 a) Installing, testing, or replacing gas piping or b) Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirement of the authority having jurisdiction. www.usaprocom.com 200159-01A SPECIFICATIONS Model PCS100T PCS150T Gas Type Natural Gas Propane Gas Natural Gas Propane Gas Maximum Input Rating 10,000 Btu/Hr 10,000 Btu/Hr 15,000 Btu/Hr 15,000 Btu/Hr Minimum Input Rating 5,000 Btu/Hr 8,000 Btu/Hr 7,000 Btu/Hr 11,000 Btu/Hr Pressure Regulator Setting 4" W.C. 9" W.C. 4" W.C. 9" W.C. Max. 9" Max. 14" Max. 9" Max. 14" Inlet Gas Pressure* (inches of water) Min. 5" Min. 11" Min. 5" Min. 11" Ignition Electronic Piezo Heater Dimensions (WxHxD) • 16" × 27.7" × 10.75" Carton Dimensions (WxHxD) • 18.9" × 30.79" × 13.25" Stove Weight • 38.5 lbs Shipping Weight • 49.5 lbs * For purposes of input adjustment. PRODUCT FEATURES SAFETY PILOT THERMOSTATIC CONTROL This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. The control automatically cycles the burner on and off to maintain a desired room temperature. PIEZO IGNITION SYSTEM This heater is equipped with an electronic piezo control system. This system requires one AAA battery (provided). 2 GAS OPTIONS AVAILABLE Your heater is equipped to operate on either Propane/LP or Natural gas. The heater is shipped from the factory ready for connecting to Propane/LP. The heater can easily be changed to Natural gas by having your qualified installer follow the instructions on page 10 and the markings on the heater. LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. 1 Batterymarch Park Quincy, MA 02269-9101 This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters. 200159-01A State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. In the State of Massachusetts the gas cock must be a T-handle type. The State of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length. www.usaprocom.com 5 UNPACKING 1. 2. 3. 4. 5 6. Remove top inner pack. Tilt carton so that heater is upright. Remove protective side packaging. Slide heater out of carton. Remove protective plastic wrap. Hold the screen, lift, and pull forward. 7. Remove log set by cutting plastic ties. 8. Carefully unwrap log. 9. Check for any shipping damage. If heater or log is damaged, promptly inform your dealer where you bought the heater. PRODUCT IDENTIFICATION Front Panel Hood Screen Heater Controls (Behind Panel) Figure 1 - Vent-Free Fireplace Insert WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30 mL) of water for every 1,000 BTUs (0.3 KWs) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather. 6 The following steps will help ensure that water vapor does not become a problem. 1. Be sure the heater is sized properly for the application, including ample combustion air and circulation air. 2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air. 3. Do not use an unvented room heater as the primary heat source. www.usaprocom.com 200159-01A AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances. 200159-01A WARNING: This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes. WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes. www.usaprocom.com 7 AIR FOR COMBUSTION AND VENTILATION VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts. 12" Ventilation Grills into Adjoining Room, Option 1 Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent. Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces. Ventilation Grills Into Adjoining Room, Option 2 Or Remove Door into Adjoining Room, Option 3 Outlet Air Outlet Air Ventilated Attic To Attic To Crawl Space 12" Inlet Air Inlet Air Figure 2 - Ventilation Air from Inside Building 8 Ventilated Crawl Space Figure 3 - Ventilation Air from Outdoors www.usaprocom.com 200159-01A INSTALLATION NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source. WARNING: A qualified service person must install heater. Follow all local codes. WARNING: Never install the heater • Model PCS100T in a bathroom. Never install model PCS150T in a bedroom or bathroom. • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 42" from the front, top, or sides of the heater • in high traffic areas • in windy or drafty areas CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may cause walls to discolor. 200159-01A IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form too much moisture. See Air for Combustion and Ventilation, pages 7 and 8. CHECK GAS TYPE Be sure your gas supply is right for your heater. Otherwise, call dealer where you bought the heater for proper type heater. CLEARANCES TO COMBUSTIBLES WARNING: You must maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall. Measure from outermost point of heater. Minimum Wall and Ceiling Clearances A. Clearances from outermost point of heater to any combustible side wall should not be less than 8". B. Clearances from the heater to the ceiling should not be less than 28". Note: When heater is installed directly on carpeting, tile or other combustible material, other than wood flooring, the heater must be installed on a metal or wood panel extending the full width and depth of the heater. Ceiling 28" Min. Side Wall 8" Min. 8" Min. Side Wall Front View Figure 4 - Minimum Clearances to Wall and Ceiling www.usaprocom.com 9 INSTALLATION GAS SELECTION This appliance is factory preset for propane/LP gas. No changes are required for connecting to propane/LP. Only a qualified installer or service technician can perform gas selection and connecting to gas supply. 4. Apply thread sealant to the threads on the connection fitting. While pushing in, rotate the fitting clockwise until the threads engage the regulator. After the fitting has been hand tightened into the regulator use a wrench to complete tightening of the fitting. Gas Connection CAUTION: Two gas line installations at the same time are prohibited. CAUTION: To avoid gas leakage for the gas not being used at the inlet of regulator, a qualified installer or service technician must use supplied plug. Figure 5 - Side of Heater Insert Gas Fitting for Propane/LP Gas Insert Gas Fitting for Natural Gas WARNING: Do not attempt to access or change the setting of the fuel selection means. 1. The inlet regulator is color coded for identification of the correct gas type. Blue is for propane (LP gas) and yellow is for natural gas. 2. The inlet regulator requires a 3/8" NPT threaded fitting. Apply a thread sealant that is rated for use with the type of gas that is being used. 3. Determine the type of gas that will be used by the appliance. If your gas type is Propane/LP remove the blue dust cover. If your gas type is Natural gas remove plug from natural gas inlet. Remove blue dust cover from propane/LP inlet and install plug. This will keep debris out of regulator. Note: After the outside plug on the bottom of the regulator has been removed, you will notice a color coded plunger on the inside of the regulator. This is normal. When the inlet connection fitting is inserted and tightened, this plunger will be pushed back by the fitting making all of the adjustments to the gas being supplied. 10 Blue Propane/LP Gas Plunger Underneath Dust Cover Yellow Natural Gas Plunger Underneath Plug Figure 6 - Gas Regulator Make sure the type of gas being used is correct. Check to make sure the connection fitting is in the correct inlet on the regulator. Refer to Connecting to Gas Supply, page 11. If you are using natural gas and the pilot will not light, see Troubleshooting, page 23. www.usaprocom.com 200159-01A INSTALLATION BUILT-IN FIREPLACE INSTALLATION WARNING: Do not allow any combustible materials to overlap the firebox front. WARNING: Do not allow combustible or noncombustible materials to cover any necessary openings like louvered slots. 1/4" Clearance to Facia 3/8" Clearance to Sides, Back and Top 15 5/8" 16" WARNING: Never modify or cover the louvered slots on the front of the firebox. 12" 1 3/4" Slope Factor 9" 6" 3" 5" 6" 8" 10" 12" To Ceiling 4" 1 1/2" Fireplace Hood Top Figure 8 - Fireplace Clearances 9 1/4" 26 1/8" 1. Frame in rough opening. Use dimensions shown in Figure 9 for the rough opening. If installing in a corner, use dimensions shown in Figure 10 (page 12) for the rough opening. The height is 19", which is the same as the wall opening above. 2. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening. Safe Zone 19 3/5" NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the fireplace may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual (see Figure 4, page 9 and Figure 8). Figure 7 - Clearance to Combustibles 28" Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of the fireplace flush with wall. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 7. 11" 15 5/8" Figure 9 - Rough Opening for Wall Installation 200159-01A www.usaprocom.com 11 19" 90° 25 3. Attach gas line to fireplace gas regulator. See Connecting to Gas Supply, page 13. 4. Check all gas connections for leaks. See Checking Gas Connections, page 15. IMPORTANT: When finishing your firebox, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc, must have 1/2" clearance to the sides and top of the firebox. Combustible materials should never overlap the firebox front facing. /18 " INSTALLATION 15 5/8" 36 1/2" Figure 10 - Rough Opening for Corner Installation CABINET MANTEL If using a cabinet mantel, assemble following the instructions included with the mantel at this time. Note: Some mantels are designed with physical and chemical distress to enhance the realistic appearance of the wood. 1. Carefully push the fireplace insert into the mantel from the front as shown in Figure 11. 2. Position the fireplace against the wall in the desired location. Figure 11 - Installing Fireplace Insert Into Mantel 12 www.usaprocom.com 200159-01A INSTALLATION CONNECTING TO GAS SUPPLY WARNING: A qualified service technician must connect heater to gas supply. Follow all local codes. CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting into gas piping and/or fittings. WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator. CAUTION: Use pipe joint sealant that is resistant to gas (Propane/LP or Natural Gas). WARNING: For natural gas, Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas. WARNING: Do not overtighten gas connections. CAUTION: Use only new, black iron or steel pipe. Internally tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur. CAUTION: For natural gas, check your gas line pressure before connecting heater to gas line. Gas line pressure must be no greater than 9" of water. If gas line pressure is higher, heater regulator damage could occur. CAUTION: For propane/ LP gas, never connect heater directly to the gas supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and gas supply. 200159-01A Before installing heater, make sure you have the items listed below: • external regulator for propane/LP unit only (supplied by installer) • piping (check local codes) • sealant (resistant to natural gas and propane/LP gas) • equipment shutoff valve* • test gauge connection* • sediment trap • tee joint • pipe wrench • flexible gas hose (check local codes) * A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design certified equipment shutoff valve from your dealer. Typical Inlet Pipe Diameters Use 3/8" black iron pipe or greater. Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 12, page 14). IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. For propane/LP installations, apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. www.usaprocom.com 13 INSTALLATION The installer must supply an external regula- Install sediment trap in supply line as shown tor. The external regulator will reduce incom- in Figure 12. Place sediment trap where it is ing gas pressure. You must reduce incoming within reach for cleaning. Place sediment trap gas pressure to between 11" and 14" of water. where trapped matter is not likely to freeze. If you do not reduce incoming gas pressure, A sediment trap traps moisture and contamiheater regulator damage could occur. Install nants. This keeps them from going into heater external regulator with the vent pointing down controls. If sediment trap is not installed or is as shown in Figure 13. Pointing the vent down installed wrong, heater may not run properly. protects it from freezing rain or sleet. 3/8" NPT Ground Pipe Nipple Joint Union External Equipment Regulator with Shutoff Valve Propane/LP Tee Joint Vent Pointing Supply Tank Down Reducer Natural Gas Bushing to Test Gauge From Gas Meter Connection* 1/8" NPT (5" W.C.** to 9" W.C. Pressure) 1/8" NPT Plug Tap Propane/LP From External Regulator Tee Joint (11" W.C.** Sediment to 14" W.C. Pipe Nipple 3" Minimum Pressure) Trap Gap Figure 12 - Gas Connection Figure 13 - External Regulator with Vent Pointing Down * Purchase the optional CSA design-certified equipment shutoff valve from your dealer. Gas Regulator Inlet Connector Figure 14 - Gas Regulator Location and Gas Line Access into Stove Cabinet 14 www.usaprocom.com 200159-01A INSTALLATION CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. If bubbles form, there is a leak. Correct all leaks at once. PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. If bubbles form, there may be a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Open Equipment Shutoff Valve Closed Figure 15 - Equipment Shutoff Valve 200159-01A Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 15). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air. 3. Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figure 16 or 17). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. 4. Correct all leaks at once. Propane/LP Supply Tank Equipment Shutoff Valve External Regulator with Control Valve Location Vent Pointing Down Figure 16 - Checking Gas Joints for Propane/LP Gas Gas Meter Equipment Shutoff Valve Control Valve Location Figure 17 - Checking Gas Joints for Natural Gas www.usaprocom.com 15 INSTALLATION PRESSURE TESTING HEATER GAS CONNECTIONS 1. Open equipment shutoff valve (see Figure 17, page 15). Apply a noncorrosive leak 15, page 16). detection fluid to all joints. Bubbles forming show a leak. 2. Open main gas valve located on or near gas meter for natural gas or open pro- 5. Correct all leaks at once. pane/LP supply tank valve. 6. Light heater (see Lighting Instructions on 3. Make sure control knob of heater is in the page 18). Check all other internal joints OFF position. for leaks. 4. Check all joints from equipment shutoff 7. Turn off heater (see To Turn Off Gas Appliance, page 19). valve to control valve (see Figure 16 or INSTALLING LOGS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. CAUTION: After installation, and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to high, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot. 1. Install log #1 on the rear plate as shown in Figure 19. 2. Install log #2 as shown in Figure 20. 3. Install log #3 and log #4 as shown in Figure 21. IMPORTANT: Make sure logs do not cover any burner ports. It is very important to install the logs exactly as instructed. Do not modify logs. Use only logs supplied with heater. Log #1 Figure 19 - Installing Log #1 Log #2 Figure 20 - Installing Log #2 Rear Plate Figure 18 - Stove Cabinet 16 Log #4 Log #3 Figure 21 - Installing Log #3 & #4 www.usaprocom.com 200159-01A INSTALLATION BATTERY INSTRUCTIONS CAUTION: Do not dispose of batteries in fire, batteries may explode or leak. • Battery is included. • Remove battery when depleted. • Be sure to observe proper polarity (+/-) when installing or replacing the battery. Damage due to improper battery installation may void the warranty on the product. • For long periods of non-operation, remove batteries from all components for safety. Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap. AAA Battery Positive UP Figure 22 - Installing Battery in Ignitor OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electric switch; do 200159-01A not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. www.usaprocom.com 17 OPERATION LIGHTING INSTRUCTIONS WARNING: You must operate this heater with the screen in place. Make sure screen is installed before running heater. NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours. 1. STOP! Read the safety information above. 2. Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap. 3. Make sure equipment shutoff valve is fully open. 4. Turn control knob clockwise to the OFF position. 5. Wait five (5) minutes to clear out any gas. Then smell for gas around heater and near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step. 6. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 23). Note: The first time that the heater is operated after connecting the gas supply,the control knob should be pressed for about thirty (30) seconds. This will allow air to bleed from the gas system. If pilot does not stay lit, refer to Troubleshooting, pages 23 though 26. Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match. • If control knob does not pop up when released, contact a qualified service technician or gas supplier for repairs. 7. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the rear of the front of burner. If needed, keep pressing ignitor button until pilot lights. 18 Note: If pilot does not stay lit, refer to Troubleshooting, pages 23 though 26. Also contact a qualified service technician or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 19. 8. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again. 9. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO (5 and 1). CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve. WARNING: If input gas type is NG, make sure NG pilot burner ignites. If input gas type is LP, make sure LP pilot burner ignites. Control Knob Ignitor Button Figure 23 - Control Knob in the OFF Position www.usaprocom.com 200159-01A OPERATION THERMOSTAT CONTROL OPERATION The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn the burner on and off. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level between HIGH (5) and LOW (1). Note: The thermostat sensing bulb measures the temperature depending on housing construction. TO TURN OFF GAS TO APPLIANCE Shutting Off Heater Turn control knob clockwise OFF position. to the Shutting Off Burner Only (pilot stays lit ) Turn control knob clockwise to the PILOT position. MANUAL LIGHTING PROCEDURE 1. Remove screen by lifting and pulling forward. 2. Follow steps 1 through 5 under Lighting Instructions, page 18. 3. With control knob in PILOT position, strike match, and hold near pilot. Press in control knob; pilot should light. 200159-01A 4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. 5. Make sure the heater screen is in place before operating heater. www.usaprocom.com 19 INSPECTING BURNERS IMPORTANT: Owner’s should check pilot flame pattern and burner flame pattern often. Incorrect flame patterns indicate the need for cleaning (see Care and Maintenance, page 21) or service. WARNING: Only a qualified service person should service and repair heater. This includes maintenance requiring replacement or alteration of components. PILOT FLAME PATTERN Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool, which shuts the heater off. If pilot flame pattern is incorrect, as shown in Figure 25 • turn heater off (see To Turn Off Gas to Appliance, page 19) • see Troubleshooting pages 23 through 26. Natural Gas Shown WARNING: If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If the burner flame pattern shows yellow tipping, follow instructions below. Notice: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame. Natural Gas Shown NG 3-3.5" WC LP 8-11" WC NG 3-3.5" WC LP 8-11" WC Approx. 3"-6" Above Top of Logs Figure 24 - Correct Pilot Flame Pattern (Natural Gas shown) Figure 25 - Incorrect Pilot Flame Pattern (Natural Gas shown) BURNER FLAME PATTERN Figure 26 shows a correct burner flame pattern. Figure 27 shows an incorrect burner flame pattern. If burner flame pattern is incorrect then: • turn heater off (see To Turn Off Gas to Appliance, page 19). • see Troubleshooting pages 23 through 26. More Than 8" Above Top of Logs Approx. 3"-6" Above Top of Logs Figure 26 - Correct Burner Flame Pattern with Control Knob Set to HI (5) More Than 8" Above Top ofBURNER Logs Figure 27 - Incorrect Burner Flame Pattern with Control Knob Set to HI (5) PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the entrance to the burner. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean as necessary. Blocked air holes will create soot. 20 www.usaprocom.com 200159-01A CARE AND MAINTENANCE WARNING: Turn off heater and let cool before servicing. CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service technician. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc. WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage. MAIN BURNER Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off the heater and let it cool, and remove blockage or replace burner. Blocked burner flame holes will create soot. CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit every 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSl. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot and primary air inlet holes on injector for dust and dirt (see Figure 28). 3. Blow air through the ports/slots and holes in the burner. Also clean the pilot assembly. 200159-01A 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner. Repeat steps 3 and 4. Burner Tube Primary Air Inlet Holes Injector Figure 28 - Burner and Injector Holder www.usaprocom.com 21 CARE AND MAINTENANCE ODS/PILOT CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. Natural Gas Burner Use a vacuum cleaner, pressurized air, or a small, soft bristled brush to clean. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about 2" from where the pilot flame comes out of the pilot assembly (see Figure 29). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available. Ignitor Electrode Thermocouple Propane/LP Gas Burner Pilot Air Inlet Hole Pilot Air Inlet Hole Figure 29 - Pilot Inlet Air Hole CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture. • Wipe the cabinet to remove dust. LOGS • If you remove logs for cleaning, refer to Installing Logs, page 16, to properly replace logs. • Replace log(s) if broken or chipped (dime-size or larger). 22 www.usaprocom.com 200159-01A TROUBLESHOOTING WARNING: If you smell gas: • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. WARNING: Only a qualified service technician should service and repair heater. Make sure that power is turned off before proceeding. Turn off and let cool before servicing. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. Note: All troubleshooting items are listed in order of operation. Using natural gas and pilot will not light. Possible Cause Corrective Action Inlet pressure exceeds 9" WC. Bypass pressure switch. See instructions below. Pressure Switch When using natural gas (NG), there is a pressure switch that acts to turn off the gas flow to the pilot if the inlet pressure exceeds 9" WC. This is to prevent the operation of the unit on the wrong gas (propane/LP). If your natural gas supply exceeds 9" WC the unit will not operate. Either contact your gas supplier to check and adjust the inlet pressure or a qualified service technician can bypass the pressure switch. Before attempting to bypass the pressure switch, make sure the type of gas being used is correct. Check to make sure the connection fitting is in the correct inlet on the regulator. Refer to Connecting to Gas Supply, page 13 Only a qualified installer should bypass the pressure switch. To bypass the pressure switch locate the set screw on the regulator. Use a small flat bladed screw driver to turn the set screw counterclockwise 2 turns. This will bypass the pressure switch function. The entire gas delivery piping including connections inside the heater should be leak tested by the qualified installer. After leak testing the qualified installer should light the appliance. Refer to the correct flame pattern as illustrated on page 20 All flame patterns should be safely inside the product. If for any reason they are not, stop use of the appliance and call for repairs. NG Problem Pressure Switch Set Screw Figure 30 - Gas Regulator Pressure Switch 200159-01A www.usaprocom.com 23 TROUBLESHOOTING Problem Possible Cause Corrective Action When ignitor button is 1. Ignitor electrode is posi- 1. Replace electrode. pressed in, there is no tioned wrong. Ignitor elecspark at ODS/pilot trode is broken. 2. Ignitor electrode is not con- 2. Replace ignitor cable nected to ignitor cable. 3. Ignitor cable is pinched or 3. Free ignitor cable if pinched wet. by any metal or tubing. Keep ignitor cable dry. 4 Broken ignitor cable. 4. Replace ignitor cable. 5. Bad piezo ignitor. 5. Replace piezo ignitor. 6. Low battery. 6. Replace battery. When ignitor button is 1. Gas supply is turned off or pressed in there is a equipment shutoff valve is spark at ODS/pilot but no closed. pilot flame present. 2. C o n t r o l k n o b n o t f u l l y pressed in while pressing ignitor button. 3. Air in gas lines (new installation or recent gas interruption). 4. ODS / pilot is clogged. 1. Turn on gas supply or open equipment shutoff valve. 2. Fully press in control knob while pressing ignitor button. 3. Continue holding down control knob. Repeat igniting operation until air is removed. 4. Clean ODS/pilot (see Care and Maintenance, page 21) or replace ODS/pilot assembly. 5. Incorrect inlet gas pressure 5. Check inlet gas pressure or or inlet regulator is damaged. replace inlet gas regulator. 6. Control knob not in PILOT 6. Turn control knob to PILOT position. position. 7. Depleted gas supply (pro- 7. Contact local propane/LP pane). gas company. ODS/pilot lights but flame 1. Control knob is not fully 1. Press in control knob fully. goes out when control pressed in. knob is released. 2. Control knob is not pressed 2. After ODS/pilot lights, keep in long enough. control knob pressed in 30 seconds. 3. Equipment shutoff valve is 3. Fully open equipment shutoff not fully open. valve. 4. Thermocouple connection is 4. Hand tighten until snug, and loose at control valve. then tighten 1/4 turn more. 5. Pilot flame not touching 5. A) Contact local natural or thermocouple, which allows propane/LP gas company thermocouple to cool, causing pilot flame to go out. This B) Clean ODS/pilot (see problem could be caused by Care and Maintenance, one or both of the following: page 21) or replace ODS/ A) Low gas pressure pilot assembly B) Dirty or partially clogged ODS/pilot 6. Thermocouple damaged. 6. Replace thermocouple. 7. Control valve damaged. 7. Contact customer service. 24 www.usaprocom.com 200159-01A TROUBLESHOOTING Problem Possible Cause Corrective Action Burner(s) does not light 1. Burner orifice is clogged. after ODS/pilot is lit 1. Clean burner orifice (see Care and Maintenance, page 21) or replace burner orifice. 2. Burner orifice diameter is too 2. Replace burner orifice. small. 3. Inlet gas pressure is too low. 3. Contact local gas supplier. Delayed ignition of 1. Manifold pressure is too low. 1. Contact local gas supplier. burner(s). 2. Burner orifice is clogged. 2. Clean burner (see Care and Maintenance, page 21) or replace burner orifice. Burner backfiring during 1. Burner orifice is clogged or 1. Clean burner orifice (see combustion damaged. Care and Maintenance, page 21) or replace burner orifice. 2. Burner is damaged. 2. Contact dealer or customer 3. Gas regulator is damaged. service. 3. Replace gas regulator. High yellow flame during 1. Not enough air. burner combustion 1. Check burner for dirt and debris. If found, clean burner (see Care and Maintenance, page 21). 2. Gas regulator is defective. 2. Replace gas regulator. 3. Inlet gas pressure is too low. 3. Contact local gas supplier. Gas odor during com- 1. Foreign matter between 1. Take apart gas tubing and bustion. control valve and burner. remove foreign matter. 2. Gas leak. (See Warning 2. Locate and correct all leaks Statement at top of page 23). (see Checking Gas Connections, page 15). Slight smoke or odor dur- 1. Residues from manufactur- 1. Problem will stop after a few ing initial operation ing process. hours of operation. Heater produces a whis- 1. Turning control knob to high 1. Turn control knob to low (1) tling noise when burner (5) position when burner is position and let warm up for is lit..0 cold. a minute. 2. Air in gas line. 2. Operate burner until air is removed from line. Have gas line checked by local gas supplier. 3. Air passageways on heater 3 Observe minimum installaare blocked. tion clearances (Figure 4, page 9) 4. Dirty or partially clogged 4 Clean burner (see Care and burner orifice. Maintenance, page 21) or replace burner orifice. 200159-01A www.usaprocom.com 25 TROUBLESHOOTING Problem Possible Cause Corrective Action Heater produces a click- 1. Metal is expanding while 1. This is common with most ing/ticking noise just after heating or contracting while heaters. If noise is excesburner is lit or shut off. cooling. sive, contact qualified service technician. White powder residue 1. When heated, the vapors 1. Turn heater off when using forming within burner from furniture polish, wax, furniture polish, wax, carpet box or on adjacent walls carpet cleaners, etc., turn cleaner or similar products. or furniture into white powder residue. Heater produces un- 1. Heater is burning vapors from 1. Ventilate room. Stop using odor causing products while wanted odors. paint, hair spray, glues, etc. See IMPORTANT statement, heater is running. page 23. 2. Gas leak. See Warning State- 2. Locate and correct all leaks (see Checking Gas Connecment at the top of page 23. tions, page 15). 3. Refill supply tank (Propane/ 3 Low fuel supply. LP models). Heater shuts off in use 1. Not enough fresh air is avail- 1. Open window and/or door for (ODS operates). able. ventilation. 2. Low line pressure. 2. Contact local gas supplier. 3. O D S / p i l o t i s p a r t i a l l y 3. Clean ODS/pilot (see Care clogged. and Maintenance, page 21). Gas odor exists even 1. Gas leak. See Warning 1. Locate and correct all leaks when control knob is in Statement at top of page 23. (see Checking Gas ConnecOFF position. tions, page 15). 2. Control valve is defective. 2. Contact customer service. Moisture/condensation noticed on windows. 26 1. Not enough combustion/ ventilation air. www.usaprocom.com 1. Refer to Air for Combustion and Ventilation requirements, page 7. 200159-01A REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement parts, call Customer Service toll free at 1-866-573-0674 for referral information. When calling Customer Service or your dealer, have ready: • Your name • Your address • Model and serial number of your heater • How heater was malfunctioning • Type of gas used (Propane/LP or Natural gas/NG) • Purchase date Usually, we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s) call Customer Service toll free at 1-866-573-0674 for referral information. When calling Customer Service have ready: • Model number of your heater • The replacement part number ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, contact ProCom Heating, Inc. at 1-866-573-0674 for information. EQUIPMENT SHUTOFF VALVE For all models. Equipment shutoff valve with 1/8" NPT tap. MANTELS PCS(100/150)T-A-(TA/W/AS), and HS150T-T-(AS/W) series. SERVICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • propane/LP gas supply might be low (propane/LP units only) You may feel your gas pressure is too low. If so, contact your local gas supplier. TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact ProCom Heating, Inc. at 1-866-573-0674. When calling, please have your model and serial numbers of your heater ready. 200159-01A www.usaprocom.com 27 PARTS MODEL PCS100T & PCS150T 1 2 4 3 5 14 10 13 6 9 12 11 8 15 7 17 18 16 28 www.usaprocom.com 200159-01A PARTS MODEL PCS100T & PCS150T This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 27 of this manual. ITEM PART # 1 **150PCS102B-01 Front Panel Assembly DESCRIPTION QTY 1 2 15PCS1014-01 Bottom Door Panel 1 3 150PCS102B-02 Screen Assembly 1 4 FB32A-155 Magnet 2 5 RVD88-4/9 Dual Fuel Regulator 1 6 ND0310A-400 ODS Pilot 1 7 PIMDN1-01 Ignitor 1 8 STL1001-250-B Thermostat Valve 1 9 ML073-01 Ignitor Cable 2 10 **15PCS1017-01 Regulator Bracket 1 11 **15PCS1019-01 Control Panel Door 1 12 **15PCS1016-01 Thermostat Valve Bracket 1 13 **15PCS2000B-01 Burner Assembly 1 14 **RVD88-YJ Connector Assembly 1 15 15PCS1022-01 Log #1 1 16 15PCS1023-01 Log #2 1 17 15PCS1024-01 Log #3 1 18 15PCS1025-01 Log #4 1 PART AVAILABLE - NOT SHOWN ML065-01 Thermostat Bulb Clip 2 ** Not a field replaceable part. 200159-01A www.usaprocom.com 29 NOTES ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ 30 www.usaprocom.com 200159-01A NOTES ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ 200159-01A www.usaprocom.com 31 WARRANTY KEEP THIS WARRANTY Model ________________________________ Serial No. _____________________________ Date Purchased ________________________ Keep receipt for warranty verification. REGISTER YOUR PRODUCT AT WWW.USAPROCOM.COM IMPORTANT: We urge you to register your product within 10 days of date of installation, complete with entire serial number which can be found on the rating plate. Please fill out the warranty information above for your personal records. Retain this manual for future reference. Always specify model and serial numbers when communicating with customer service. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY ProCom Heating, Inc. warrants this product to be free from defects in materials and components for ONE (1) year from the date of first purchase, provided that the product has been properly installed by a qualified installer in accordance with all local codes and instructions furnished with the unit, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty, the Bill of Sale or canceled check must be presented. RESPONSIBILITY OF OWNER This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through ProCom Heating, Inc. who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. IMPORTANT: The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit or the warranty is voided. WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner. TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT, THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES. INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE. PROCOM HEATING, INC.'S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND PROCOM HEATING, INC. SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of accidental or consequential damages, the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you. This warranty gives you specific legal right, and you may also have other rights that vary from state to state. ProCom Heating, Inc. Bowling Green, KY 42101 www.usaprocom.com 1-866-573-0674 200159-01 Rev. A 08/14
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project