Culligan Aqua-Cleer Drinking Water System Owner's Guide
Advertisement
Advertisement
Culligan
®
Aqua-Cleer
®
Advanced
Drinking
Water
Systems
Owners
Guide
i 01020485
THANK YOU
AND WELCOME TO YOUR NEW WORLD OF BETTER LIVING WITH CULLIGAN WATER.
Notice: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
For installations in Massachusetts: Massachusetts Plumbing Code 248 CMR shall be adhered to. Consult your licensed plumber for installation of this system. The use of saddle valves is not permitted in Massachusetts.
Check with your public works department for applicable local plumbing and sanitation codes. Follow your local codes if they differ from the standards used in this manual.
Operational, maintenance and replacement requirements are essential for this product to perform properly. Talk to you Culligan dealer about a service and maintenance program to ensure your filters are replaced in a timely manner and annual water tests are also recommended (especially on well water) to ensure the system is functioning properly.
Culligan International Company
9399 West Higgins Road
Rosemont, Il. 60018
1-800-Culligan www.culligan.com
Products manufactured and marketed by Culligan International Company (Culligan) and its affiliates are protected by patents issued or pending in the United States and other countries. Culligan reserves the right to change the specifications referred to in this literature at any time, without prior notice. Culligan,
Aqua Cleer, and Culligan Man are trademarks of Culligan International Company or its affiliates.
Table of
Contents
01020485 ii
About Your
System
1 01020485
Thank you for choosing a Culligan Aqua-Cleer advanced drinking water system. Your new system is designed to bring you years of deliciously crystal-clear Culligan water. The best part is it comes right from the tap. No more lugging around bottles or waiting for pitchers to slowly fill up. With your continuous supply of great tasting water, not only can you get your 8 glasses a day but you can easily use it for cooking, coffee, juice, baby formula, ice cubes, anything you use water with.
The important thing to remember is to change out your filters on a regular basis. The quality of your water is only as good as the quality of your filters. Each filter is designed to last for 1,000 gallons (roughly 12 months). Membranes will last longer if used with pre-filtration. A flow monitor is available with your system to let you know when you have consumed 1,000 gallons of water through your system. If you did not purchase one with your system, you may consider asking your Culligan man about having one installed.
Faucets with reminder lights are also available.
System Specifications:
Dimensions
Storage Tank
Capacity
Reverse Osmosis
Efficiency Rating
Reverse Osmosis
Recovery Rating
Filter Assembly
Standard Storage Tank
Medium Storage Tank
Large Storage Tank
Standard
Medium
Large
RO30
RO50
RO75
RO30
RO50
RO75
Filtration Options:
Sequence of Filtration Type of Filtration
13.8” wide x 4.2” deep x 15.5” high
9” diameter x 14” high
11” diameter x 14” high
15.5: diameter x 24” high
2 gallons
3 gallons
9 gallons
16.23%
15.79%
14.77%
30.41%
32.55%
28.58%
Pre-Filtration
Membrane
Advanced Filtration
Remineralization
Post-Filtration
Sediment
Carbon
Reverse Osmosis
Nano Filtration
Total Defense
Arsenic
Perchlorate*
Mineral Boost
Carbon
Specification
1
2
3
Block
Granulated Active Carbon
Granulated Active Carbon - Large
30 gpd
50 gpd
75 gpd
30 gpd
Speciality Carbon Block
Specialty Media 1
Specialty Media 1
Specialty Media
Granulated Activated Carbon Block
* Cartridges not for sale in California
1
Cartridges not for sale in California or Iowa.
Specialty media cartridges must be installed after the RO membrane and system must have a Performance Indicator Device (PID) installed to track gallon usage.
Purpose of each level of filtration:
Pre-Filtration:
Pre-filtration for this system is used to reducing large contaminants from the water before they reach either the reverse osmosis or nano filtration membrane. The use of pre-filtration cartridges helps extent the membrane’s life. There are two types of pre-filtration available with this system: sediment filtration and carbon filtration.
Sediment Filtration: Sediment is defined as sand, dirt, silt, fine sand and or coarse sand that can be found in many water supplies.
Carbon Filtration: Carbon is used to reduce chlorine taste and odor. Most people often describe this taste as being slightly chemical or they equate their drinking water to that of the local pool. Municipalities use chlorine to disinfect the water on the way to your home. This is a necessary step to delivering safe water to your home but depending on the level of chlorine by the time it reaches your home the taste of your water may be unpalatable.
Membrane Technologies:
The Aqua-Cleer system can utilize two different membrane technologies; reverse osmosis and nano filtration. Each one of these technologies use a tightly woven membrane that acts as a barrier to contaminants.
Water is pushed up against this membrane at pressure. Depending on the weave of the membrane only a certain percentage of contaminants can pass through. Reverse Osmosis can reduce up to 99% of contaminants. The reason you may choose nano filtration versus reverse osmosis is often a question of taste.
Some of the things that give water its taste are minerals such as calcium and magnesium. A nano filtration membrane will leave more of those minerals in the water.
Advanced Filtration:
The advanced filtration cartridges are specifically designed to reduce contaminants that reverse osmosis membranes are not efficient in removing.
Total Defense:
The Total Defense cartridge should be added to your system to deal with lead, mercury, aesthetic chloramines, aesthetic chlorine taste and odor, cysts, Volatile Organic Compounds (VOC) and MTBE.
• Chloramines have a stronger taste and are more difficult to remove than chlorine.
• Mercury is a toxin that can cause kidney damage.
• Lead is a toxin that can cause kidney problems or high blood pressure in adults and developmental problems in children.
• Cysts are a common cause of health issues. They can be found in some municipal water sources but more often found in wells under the influence of surface water.
• VOC is a name given to a wide range of organic contaminants, some are known to be carcinogenic.
• MTBE was used in gasoline to reduce emissions and is considered harmful.
Mineral Boost
The Mineral Boost cartridge adds healthy amounts of natural calcium minerals back into reverse osmosis water to create amazing tasting, optimally alkaline, pH balanced water. Benefits include:
• Raises RO water TDS by 20 ppm to 30 ppm
• Raises RO water pH by 1 to 2 pH
01020485 2
3 01020485
Perchlorate*:
Perchlorate is a by-product of munitions manufacturing (common in solid rocket fuel, road flares, etc) that can be found in some water sources.
Arsenic:
Arsenic (As) is found naturally in some well water. Arsenic in water has no color, taste or odor. It must be measured by a lab test. Public water utilities must have their water tested for arsenic. You can get the result from your water utility. If you have your own well, you can have the water tested by an accredited lab. The local health department or the state environmental health agency can provide a list of certified labs. Culligan International is one such lab. For more information please contact your local Culligan dealer. For additional information about the arsenic in water can be found through the EPA’s website at www.epa.gov/safewater/arsenic.html.
There are two forms of arsenic: pentavalent arsenic (As (V)) and trivalent arsenic
(As (III)). Special sampling procedures are needed for a lab to determine what type and how much of each type of arsenic is in the water. In well water, arsenic may be pentavalent, trivalent, or a combination of both. Reverse osmosis membranes are effective at reducing pentavalent arsenic but not trivalent arsenic. The Arsenic specific cartridge was specifically designed to reduce trivalent arsenic.
* Cartridges not for sale in California.
Aqua-Cleer Faucet
Installation
Monitor Sensor
Drain
Drain Line from Air Gap to Drain (3/8” Tubing)
Cold Water Supply
Drain Connection
Monitor
Post Filter
1/4” Drain Line to Air Gap in
Faucet
Feedline 1/4” Tubing
Aqua-Cleer Manifold
Ball Valve
3/8” Tubing to
Faucet Product Port
Tank
To Bottom Of RO Cartridge
Figure 1.
NOTE Install the drain line so that it runs downward with no loops or low spots.
Otherwise the unit will overflow at the air gap siphon break built into the faucet, or make irritating gurgling sounds. The 1/4” concentrate line that leads to the faucet should be installed in a straight vertical path to avoid making a gurgling noise. For installations in Massachusetts: Massachusetts
Plumbing Code 248 CMR shall be adhered to. Consult your licensed plumber for installation of this system. The use of saddle valves is not permitted in
Massachusetts.
This owner’s guide provides visual assembly reference only. Since specialized skills are required in the assembly of the drinking water system, we recommend that you contact your local independently operated Culligan dealer to complete this installation.
Select Component Installation Locations
Dispenser Faucet
The Culligan® faucet is designed to be mounted on the rear lip of the sink. It may be installed in an existing sprayer attachment hole or in a hole drilled at the time of installation. It may also be mounted to an adjacent counter top. It should be positioned so that water is dispensed over the sink. A minimum 1-1/4” diameter hole is required. When installing the Aqua-Cleer® water quality monitor, refer to the installation instructions packaged with the monitor. Make certain the TDS level and/or gallons setting correspond to the desired water supply.
01020485 4
5 01020485
Important considerations:
• Access to the bottom (under sink) of the faucet is required for attachment of product water line.
• The faucet can be installed for left- or right-handed operation.
• There should be no under sink obstructions which would prevent smooth tubing runs to the drain connection, carbon post-filter, or RO module assembly.
Filter System Assembly
The filter system assembly is designed to be mounted on any rigid vertical surface such as a cabinet sidewall, sheetrock or exposed stud. It should be positioned such that there is access to an inlet water source and drain. The installation should also allow convenient access for servicing.
Inlet Water Supply Connection
Once a location is chosen for installation of the filter system assembly, select a nearby cold water line to provide the water source for the system. For under sink installations, the cold water faucet line can usually be tapped.
The Reservoir Tank
Position the reservoir tank near the faucet for optimum customer convenience. The standard and medium reservoir tank will weigh about 28 pounds (13 kg) when full of water, so it must be positioned on a stand or held securely by the optional mounting bracket. The reservoir operates best in the vertical position, but it will operate on its side. However, air will not escape readily and foaming may occur at the faucet nozzle. This should be explained to the customer prior to installation.
Drain Connection
The most convenient entry to the drain is directly above the P-trap of the kitchen sink. However, the concentrate water from the system can be connected to adjacent sinks or a floor drain. Extra care should be taken when entering drains near dishwashers or food waste disposals as back flow may occur through the air gap and cause flooding. See plumbing diagram on page 7 for proper air gap installation to waste connection.
Installation of Filter System Assembly
The mounting bracket contains three mounting slots. The holes are sized to accept #10 round head wood screws (not supplied). Some types of surfaces such as particle board or drywall may require the use of plastic screw anchors or toggle bolts to provide adequate support for the unit.
Install Filter Cartridges
1. Lightly lubricate the cartridge O-ring with silicone lube and insert the sediment filter cartridge into the manifold.
2. Twist the cartridge to lock it into the manifold.
See Figure 2.
Locked
Position
Unlocked
Position
Figure 2.
3. Repeat steps 1-2 and install the flushed activated carbon filter cartridge into housing and the RO membrane element. Be sure the drain adapter is in place.
NOTE 1) The RO cartridge must be inserted into the 2nd, 3rd, or 4th position on the
RO manifold.
NOTE 2) If only three cartridges are to be inserted into the manifold, the bypass
plug cartridge must be inserted in the 4th position. See Figure 3.
NOTE The activated carbon, reverse osmosis, and polishing filter cartridges must be conditioned as follows prior to installation into the Aqua-Cleer system. Your
Culligan man will do these important procedures at the time of purchase.
• Activated Carbon Cartridge - 10 minute flush to remove carbon dust
• RO Membrane - Minimum 24 hour flush to remove preservative solution
• Polishing Filter - 10 minute flush to remove carbon dust
• Mineral Boost Cartridge - 10 minute flush to remove mineral particulates
Factors Which Affect Performance
Performance of the reverse osmosis membrane is affected by several factors which must be considered when judging the condition of the system. The main factors which affect system performance are pressure, temperature, total dissolved solids level, recovery and pH.
Pressure
Water pressure affects both the quantity and quality of the water produced by the RO membrane. Generally, the more water pressure, the better the performance of the system. Be careful not to exceed 120 psi, the maximum operating pressure of the Aqua-Cleer system.
Temperature
The reverse osmosis process slows with decreasing temperature. To compensate, a temperature correction factor is used to adjust the actual performance of the RO membrane filter to the standard temperature of 77°F (25°C).
This allows the performance of the unit to be accurately gauged against Culligan’s published standards. Temperature does not affect the concentrate flow rate.
Figure 3.
Total Dissolved Solids
The minimum driving force which is necessary to stop or reverse the natural osmosis process is termed osmotic pressure. As the total dissolved solids level of the feed water increases, the amount of osmotic pressure increases and acts as back pressure against the reverse osmosis process. Osmotic pressure becomes significant at TDS levels above 500 mg/L (ppm).
Hardness
Hardness is the most common membrane foulant. If ignored, this relatively harmless component of feed water will plug a membrane over time. Use of a softener will reduce the fouling effect on a membrane.
One way to detect too much hardness in the feed water is the weight of a membrane installed for a period of time. A fouled membrane (dried) will weigh significantly more than a new membrane. The increase in weight is a result of precipitated hardness inside the membrane.
01020485 6
7 01020485
Iron
Iron is another common membrane foulant. There are a variety of types of iron, some of which cannot be removed by an iron filter. Clear water iron can be removed more effectively by a softener. Particulate iron can be removed more effectively by a 1 micron filter. Organic-bound iron can be removed only by activated carbon or macroporous anion resin. If there is enough iron to exceed the EPA secondary drinking water standard and softening the water is not an option and the iron is soluble, then an iron filter is appropriate. If none of these are an option then regular replacement of membranes will have to be accepted.
Product Water Recovery
Product water recovery plays an important role in determining membrane and system performance. Recovery refers to the amount of water produced in relation to the amount of water sent to drain. The standard calculation is:
% Recovery = Product Water ÷ (Product Water + Waste Water) x 100
The Aqua-Cleer uses a flow control assembly to restrict the flow of waste water to the drain. This restriction helps maintain pressure against the membrane. The sizing of the flow control assembly determines the recovery rating of the system. The Aqua-Cleer is manufactured with a recovery rating designed to be around
30% -40%. Depending on temperature, pressure and tolerances the actual recovery value may be slightly different for each system.
To keep the Aqua-Cleer ® system operating properly, it is necessary to change the filters and sanitize the system periodically. Typically, this should be done on an annual basis. Service frequency may vary depending on local water conditions. High sediment, chlorine, turbidity, or hardness levels may require more frequent service. Use the following as a guide.
As needed:
Clean the faucet with a soft cloth, avoid abrasive cleaners
It is recommended that you do the following annually:
(Contact your local Culligan dealer for replacement cartidges and maintenance)
1. Sanitize the System
2. Replace:
• Sediment Filter
• Activated Carbon Filter
• Polishing Filter
• Any Advanced Filtration Cartridge
• Mineral Boost Cartridge
3. Check:
• RO Membrane
• Flow control assembly
• TDS Reduction Performance
• Flow Rates (including air gap)
• Drain tubing for back-up
Perform the following steps in the order shown to sanitize your system
It is recommended to have your local Culligan dealer perform the sanitization process. Your local Culligan man has been specifically trained to test the water quality and efficiency of the system in order to determine when the RO membrane should be replaced and ensure the system is working properly.
Preliminary Steps:
1. Check for any leaks that may exist from tubing connections or the faucet.
2. Check for flow to the drain. If flowing, close tank shut-off so you can check auto shut-off operation
3. Test and record product TDS from faucet. Also observe if faucet stem is stiff to move.
4. Test and record feed TDS, and then calculate rejection percentage.
5. If rejection is acceptable - Shut off storage tank, remove tank supply tubing to collect and record product flow, and water temperature.
6. Record feed pressure if needed by attaching a pressure gauge to feed line. Use the recorded feed pressure and water temperature to check product flow rate against the supplied chart.
Membrane okay? Low production could be the result of partially plugged prefilters. If so retest after filters are changed.
7. With feed line off begin draining tank.
The Aqua-Cleer RO manifold assembly may be sanitized with 5-1/4% liquid chlorine unscented bleach.
1. Shut off water supply then remove all filters. Put bypass plugs in ports 2, 3 and 4.
2. Pour two tablespoons liquid chlorine bleach into the sanitizer cartridge and place in port 1.
3. Turn on the water supply valve and the RO faucet to allow the system to fill with water. Allow the water to flow through until the entire system for about 10 minutes or until the sanitizing solution is through.
4. Install new filters, including the post carbon filter, and membrane if needed, or reuse existing membrane. Some filters require flushing before use to remove dust
and fines. If an in-plant flush was not performed, use the single head assembly to perform this using the feed line and drain lines available. Don’t flush using the RO manifold.
5. Replace the battery in the quality monitor if applicable.
6. Discard the first glass of water from the faucet.
7. Thoroughly check for leaks.
How to
Maintain Your
System
01020485 8
Parts List
6
9
11
10
3/8” Outlet
1/4” Inlet
1
9
7
01020485
Item
1
2
3
4
5
8
9
6
7
10
11
Description
Manifold Assembly
SED1 Filter
SED2 Filter
SED3 Filter
Carbon Block Filter
Granular Activated Carbon Filter
Granular Activated Carbon Filter - Large
30 GPD Reverse Osmosis Membrane
50 GPD Reverse Osmosis Membrane
75 GPD Reverse Osmosis Membrane
Nanofiltration Reverse Osmosis Membrane*
Arsenic Filter
Perchlorate Filter**
Carbon Block Filter (MTBE, VOC)
Mineral Boost
Post Carbon Filter
Flow Control
Automatic Shut-off Valve
Faucet
2 Gallon Storage Tank
3 Gallon Storage Tank
9 Gallon Storage Tank
Ball Valve
*Monitor (Not Shown) ** Cartridge not for sale in California
Cartridge not for sale in California or Iowa.
2
3
4
5
8
Important Notice: Read this Performance Data Sheet and compare the capabilities of this system with your actual water treatment needs. It is recommended that, before installing a water treatment system, you have your water supply tested to determine your actual water treatment needs.
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about its performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is providing this Performance Data Sheet to its customers.
Company: Culligan International Company
9399 West Higgins Road, Suite 1100
Rosemont, IL 60018 USA
(847) 430-2800
Product: Culligan Aqua-Cleer Advanced Drinking Water Systems
Use Guidelines:
• Working Pressure: 40 – 120 psig (280-827 kPa)
• Do not allow exposure to temperature below 33°F (1°C)
• Maximum operating temperature: 100°F (38°C)
• These systems must be installed according to local plumbing codes on the cold water line.
• This system requires regular replacement of all filters to maintain proper operation. Depending on usage and influent water quality, the carbon, Mineral Boost and particulate filters should be changed at least annually and the reverse osmosis membrane should be replaced every 3-5 years.
Varying chlorine, sediment or TDS levels may affect replacement frequency.
CAUTION! Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The Total Defense has been tested according to NSF/ANSI 42, 53, 401 and NSF Protocol P473 for the reduction of the substances listed below. The concentration of the indicated substances in the water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, 401 and NSF Protocol P473.
NSF/ANSI Standard 42
Substance
Influent
Challenge
Concentration
2.0 mg/L + 10%
Maximum
Permissible
Product water
Concentration
Reduction
Requirements
>50% Aesthetic
Chlorine
Aesthetic
Chloramines
Particulate
(0.5 - < um)
Class I
3.0 mg/L + 10%
At least 10,000 particles/mL
0.5 mg/L
>85%
Minimum
Reduction
Average
Reduction
96.0%
96.0%
99.9%
97.9%
97.9%
99.9%
Flow Rate = 0.5 gpm (1.89 Lpm)
Capacity = 1,000 gallons (3786 L)
Performance
Data Sheet
01020485 10
11 01020485
NSF/ANSI Standard 53
Substance
MTBE
Cyst t
Influent
Challenge
Concentration
0.015 + 20%
Minimum
50,000/L
11 mg/L + 1 NTU
0.15 mg/L + 10%
Maximum
Permissible
Product water
Concentration
Reduction
Requirements
0.005 mg/L
99.95%
0.5 NTU
0.010 mg/L
Turbidity
Lead
(pH 6.5)
Lead
(pH 8.5)
Mercury
(pH 6.5)
Mercury
(pH 8.5)
Chloroform
(VOC surrogate chemical)
0.15 mg/L + 10%
0.006 mg/L +
10%
0.006 mg/L +
10%
0.300 mg/L +
10%
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.015 mg/L
Minimum
Reduction
Average
Reduction
92.1%
99.99%
99.1%
98.7%
99.3%
96.7%
89.7%
97.5%
96.4%
99.99%
99.1%
99.3%
99.3%
96.7%
95.9%
99.6%
Flow Rate = 0.5 gpm (1.89 Lpm)
Capacity = 1,000 gallons (3786 L) t Based on the use of microspheres or Cryptospordium parvum oocysts
Testing was performed under standard laboratory conditions, actual performance may vary.
NSF/ANSI Standard 401
Substance
Phenytoin
Ibuprofen
Naproxen
Estrone
Bisphenol A
Nonylphenol
Common
Names
Dilantin 1
Motrin 1
Aleve 1
Estrogen
BPA
Surfactant
Influent
Challenge
Concentration
200 ng/L ± 20%
400 ± 20%
140 ± 20%
140 ± 20%
2,000 ± 20%
1,400 ± 20%
Maximum Permissible
Product water
Concentration
30 ng/L
60 ng/L
20 ng/L
20 ng/L
300 ng/L
200 ng/L
Average
Reduction
> 95.6%
> 95.4%
> 96.4%
> 96.5%
> 98.9%
> 97.5%
Flow Rate = 0.5 gpm (1.89 Lpm)
Capacity = 1,000 gallons (3786 L)
NSF/ANSI Standard 401 are considered incidental contaminants and emerging compounds.
1 Dilantin is a registered trademark of Pfizer Inc. Motrin is a registered trademark of Johnson & Johnson
Consumer Inc. Aleve is a registered trademark of Bayer.
Substance
Alachor
Atrazine
Benzene
Carbofuran
Carbon Tetrachloride
Chlorbenzene
Chlorpicrin
2,4-d
Dibromochloropropane (Dbcp)
O-Dichlorobenzene
P-Dichlorobenzene
1,2-Dichloroethane
1,1-Dichloroethylene
Cis-1,2-Dichloroethylene
Trans-1,2-Dichloroethylene
1,2-Dichloropropane
Cis-1,3-Dichloropropylene
Dinoseb
Endrin
Ethylbenzene
Ethylene Dibromide (Edb)
Haloacetonitriles (Han):
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloracetonitrile
Haloketones (Hk):
1,1-Dichloro-2-propane
1,1,1-Trichloro-2-propane
NSF Protocol P473
Substance
Influent
Challenge
Concentration
1.5 μg/L ± 10% Perfluooroctanoic acid (PFOA) and
Perfluorooctane sulfonate (PFOS)
Flow Rate = 0.5 gpm (1.89 Lpm)
Capacity = 1,000 gallons (3786 L)
Organic Chemicals Included in Surrogate Testing:
Applies to Total Defense (TD) only.
Maximum Permissible
Product Water
Concentration
0.07 μg/L
Average
Reduction
> 95.8%
Influent Challenge
Concentration mg/L
0.110
0.052
0.080
0.040
0.088
0.083
0.170
0.086
0.050
0.100
0.081
0.190
0.078
0.077
0.015
0.080
0.079
0.170
0.053
0.088
0.044
Maximum permissible product water concentration mg/L
0.002
0.000
0.001
0.001
0.005
0.001
0.001
0.001
0.001
0.003
0.001
0.001
0.002
0.001
0.000
0.001
0.001
0.000
0.001
0.001
0.000
0.022
0.024
0.001
0.015
0.007
0.008
0.001
0.001
0.000
0.000
0.000
0.000
01020485 12
13 01020485
Substance
Heptachlor
Heptachlor Epoxide
Hexachlorobutadiene
Hexachlorocyclopentadiene
Lindane
Methoxychlor
Pentachloophenol
Simazine
Styrene
1,1,2,2-Tetrachloroethane
Tetrachloroethylene
Toluene
2,4,5-tp (Silvex)
Tribromoacetic Acid
1,2,4-Trichlorobenzene
1,1,1-Trichloroethane
1,1,2-Trichloroethane
Trichloroethylene
Trihalomethanes (Includes):
Chloroform (Surrogate
Chemical)
Bromoform
Bromodichloromethane
Chlorodibromomethane
Xylenes (Total)
0.150
0.081
0.081
0.078
0.270
0.042
0.160
0.084
0.150
0.180
Influent Challenge
Concentration mg/L
0.250
0.011
0.044
0.060
0.055
0.050
0.096
0.120
0.001
0.001
0.001
0.001
0.002
0.001
0.001
0.005
0.001
0.001
Maximum permissible product water concentration mg/L
0.000
0.000
0.001
0.000
0.000
0.000
0.001
0.004
0.300
0.070
0.015
0.001
AS3
The AS3 has been tested according to NSF/ANSI 53 for the reduction of the substances listed below. The concentration of the indicated substances in the water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 53.
Conforms to NSF/ANSI Standard 53 for arsenic (trivalent and pentavalent) reduction. See Arsenic Fact section for an explanation of reduction performance.
Substance
Influent
Challenge
Concentration mg/L
Maximum
Permissible
Product water
Concentration mg/L
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 53
Trivalent Arsenic pH 6.5
Trivalent Arsenic pH 8.5
0.050 + 10%
0.050 + 10%
0.010
0.010
Pentavalent
Arsenic
0.050 + 10% 0.010
Flow Rate = 0.035 gpm (0.13 Lpm)
Capacity = 1000 gallons (3786 L)
1000 gallon capacity is only for use with PID
Testing was performed under standard laboratory conditions, actual performance may vary
94.9%
98.0%
97.4%
01020485 14
15 01020485
RO30
This system has been tested according to NSF/ANSI 58 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 58.
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater.
Substance Reduction 1
Contaminant Average Influent
Concentration mg/L
Average Effluent
Concentration mg/L
Average
Percent
Reduction
Maximum
Effluent
Concentration mg/L
0.003
Arsenic
(Pentavalent) 2
Barium
Cadmium
Hexavalent
Chromium
Trivalent
Chromium
Copper
Fluoride
Lead
0.053
11.0
0.031
0.31
0.31
0.001
0.37
0.0004
0.011
0.005
97.6%
96.6%
98.7%
96.4%
98.5%
0.49
0.0005
0.014
0.007
3.0
8.2
0.16
0.02
0.4
0.002
99.3%
94.5%
99.0%
0.033
0.7
0.002
Nitrate/
Nitrite (both as
N)
Nitrate 5
Nitrite
Radium
226/228 3
30 +/- 10%
27.0 +/- 10%
3.0 +/- 10%
25pCi/L
10.0
1.0
5pCi/L
79.1%
79.6%
72.6%
80.0% 5pCi/L
Selenium
Cyst 4
0.097
>50,000/mL
0.003
97.3%
99.99%
0.004
Turbidity 11 NTU 0.1 NTU 99.1% 0.1 NTU
1 While testing was performed under standard laboratory conditions, actual performance may vary depending on
2 water pressure, temperatures and other substances, which may be found in your water.
This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts Sheet for further information.
3 Based upon testing methods using Barium as a surrogate. All concentrations in pCi/L pico curie/L.
4 Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium.
5 Units are not certified on water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended.
RO50
This system has been tested according to NSF/ANSI 58 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 58.
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater.
Substance Reduction 1
Contaminant Average Influent
Concentration mg/L
Average Effluent
Concentration mg/L
Average
Percent
Reduction
Maximum
Effluent
Concentration mg/L
Arsenic
(Pentavalent) 2
Barium
Cadmium
Hexavalent
Chromium
Trivalent
Chromium
Copper
Fluoride
Lead
Nitrate/
Nitrite (both as
N)
Nitrate 5
Nitrite
Radium
226/228 3
Selenium
Cyst 4
0.053
11.0
0.031
0.31
0.31
3.0
8.2
0.16
30 +/- 10%
27.0 +/- 10%
3.0 +/- 10%
25pCi/L
0.001
0.37
0.0004
0.011
0.005
0.02
0.4
0.002
10.0
1.0
5pCi/L
97.6%
96.6%
98.7%
96.4%
98.5%
99.3%
94.5%
99.0%
83.5%
84.3%
74.6%
80.0%
0.003
0.49
0.0005
0.014
0.007
0.033
0.7
0.002
5pCi/L
0.097
>50,000/mL
0.003
97.3%
99.99%
0.004
Turbidity 11 NTU 0.1 NTU 99.1% 0.1 NTU
1 While testing was performed under standard laboratory conditions, actual performance may vary depending on
2 water pressure, temperatures and other substances, which may be found in your water.
This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts Sheet for further information.
3 Based upon testing methods using Barium as a surrogate. All concentrations in pCi/L pico curie/L.
4 Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium.
5 Units are not certified on water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended.
01020485 16
17 01020485
RO75
This system has been tested according to NSF/ANSI 58 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 58.
This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater.
Substance Reduction 1
Contaminant Average Influent
Concentration mg/L
Average Effluent
Concentration mg/L
Average
Percent
Reduction
Maximum
Effluent
Concentration mg/L
0.003
Arsenic
(Pentavalent) 2
Barium
Cadmium
Hexavalent
Chromium
Trivalent
Chromium
Copper
Fluoride
Lead
0.053
11.0
0.031
0.31
0.31
0.001
0.37
0.0004
0.011
0.005
97.6%
96.6%
98.7%
96.4%
98.5%
0.49
0.0005
0.014
0.007
3.0
8.2
0.16
0.02
0.4
0.002
99.3%
94.5%
99.0%
0.033
0.7
0.002
Nitrate/
Nitrite (both as
N)
Nitrate 5
Nitrite
Radium
226/228 3
30 +/- 10%
27.0 +/- 10%
3.0 +/- 10%
25pCi/L
10.0
1.0
5pCi/L
76.2%
76.7%
69.8%
80.0% 5pCi/L
Selenium
Cyst 4
0.097
>50,000/mL
0.003
97.3%
99.99%
0.004
Turbidity 11 NTU 0.1 NTU 99.1% 0.1 NTU
1 While testing was performed under standard laboratory conditions, actual performance may vary depending on
2 water pressure, temperatures and other substances, which may be found in your water.
This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5) or arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramines (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts Sheet for further information.
3 Based upon testing methods using Barium as a surrogate. All concentrations in pCi/L pico curie/L.
4 Includes Giardia lamblia, Entamoeba histolyca and Cryptosporidium.
5 Units are not certified on water supplies with a pressure less than 40 psi (280 kPa). A booster pump is strongly recommended.
Output (Total Dissolved Solids (TDS) Reduction and Output Production) 1 – RO30
Tank Size 2 gallon 3 gallon 9 gallon
Product System Daily Prod. Rate To Pressurized Storage Tank 11.27 gpd 11.27 gpd 11.27 gpd
Prod. Rate without Storage Tank To Atmosphere 36 gpd 36 gpd 36 gpd
Efficiency Rating 2 16.23% 16.23% 16.23%
Recovery Rating 3
Influent Challenge Concentration (Mg/L)
Max. Permissible Product Water Concentration (Mg/L)
Minimum Percent Removal
Average Percent Removal
30.41%
770
187
95.5%
96.0%
30.41%
770
187
95.5%
96.0%
30.41%
770
187
95.5%
96.0%
1 This is a factory specification for membrane production. Actual production rate and TDS rejection
2 will depend on temperature, water pressure, TDS level, membrane variation and usage pattern.
Efficiency rating means the percentage of the influent water to the system that is available to the user
3 are reverse osmosis treated water under operating conditions that approximate daily usage.
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
Output (Total Dissolved Solids (TDS) Reduction and Output Production) 1 – RO50
Tank Size 2 gallon 3 gallon 9 gallon
Product System Daily Prod. Rate To Pressurized Storage Tank 13.93 gpd 13.93 gpd 13.93 gpd
Prod. Rate without Storage Tank To Atmosphere 50 gpd 50 gpd 50 gpd
Efficiency Rating
Recovery Rating 3
2 15.79%
32.55%
15.79%
32.55%
15.79%
32.55%
Influent Challenge Concentration (Mg/L)
Max. Permissible Product Water Concentration (Mg/L)
Minimum Percent Removal
770
187
94.4%
770
187
94.4%
770
187
94.4%
Average Percent Removal 96.8% 96.8% 96.8%
1 This is a factory specification for membrane production. Actual production rate and TDS rejection
2 will depend on temperature, water pressure, TDS level, membrane variation and usage pattern.
Efficiency rating means the percentage of the influent water to the system that is available to the user
3 are reverse osmosis treated water under operating conditions that approximate daily usage.
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
01020485 18
19 01020485
Output (Total Dissolved Solids (TDS) Reduction and Output Production) 1 – RO75
Tank Size 2 gallon 3 gallon 9 gallon
Product System Daily Prod. Rate To Pressurized Storage Tank 20.28 gpd 20.28 gpd 20.28 gpd
Prod. Rate without Storage Tank To Atmosphere 75 gpd 75 gpd 75 gpd
Efficiency Rating
Recovery Rating 3
2 14.77%
28.58%
14.77%
28.58%
14.77%
28.58%
Influent Challenge Concentration (Mg/L)
Max. Permissible Product Water Concentration (Mg/L)
Minimum Percent Removal
Average Percent Removal
770
187
94.4%
95.5%
770
187
94.4%
95.5%
770
187
94.4%
95.5%
1 This is a factory specification for membrane production. Actual production rate and TDS rejection
2 will depend on temperature, water pressure, TDS level, membrane variation and usage pattern.
Efficiency rating means the percentage of the influent water to the system that is available to the user
3 are reverse osmosis treated water under operating conditions that approximate daily usage.
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
Temperature: 77º F + 2º F pH: 7.5 + 0.5
Pressure: 50 psi Turbidity: <1 NTU
This system has been tested and shown to operate at its calculated recovery rating under standard laboratory conditions.
This reverse osmosis system contains a replaceable component critical to the efficiency of the system.
Replacement of the reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure the same efficiency and contaminant reduction performance.
The Aqua-Cleer CB, GAC, or GAC-L cartridge has been tested and certified by NSF International against NSF/ANSI Standard 42 for the effective reduction of aesthetic Chlorine Taste and Odor, the TD cartridge for the effective reduction of aesthetic Chlorine Taste and Odor and Nominal Particulate
Class 1 and against CSA B483.1.
1
The Aqua-Cleer Advanced Drinking Water System with TD cartridge has been tested and certified by NSF International against NSF/ANSI Standard
53 for the effective reduction of Cyst, Lead, Mercury, VOC, MTBE and
Turbidity, against NSF/ANSI Standard 401 2 for the effective reduction of
Phenytoin, Ibuprofen, Naproxen, Estrone, Bisphenol A and Nonyl Phenol and against CSA B483.1. The Aqua-Cleer Advanced Drinking Water
System with TD cartridge has been tested by NSF International and conforms against NSF Protocol P473 for the effective reduction of Perfluooroctanoic acid (PFOA) and Perfluorooctane sulfonate (PFOS).
The Aqua-Cleer Advanced Drinking Water System with RO30, RO50 or RO75 has been tested and certified by NSF International against NSF/ANSI Standard 58 for the effective reduction of TDS, pentavalent arsenic, barium, cadmium, hexavalent and trivalent chromium, copper, lead, nitrate/nitrite, radium
226/228 and selenium and against CSA B483.1.
3
The Aqua-Cleer Advanced Drinking Water System with AS3 has been tested and certified by NSF International against NSF/ANSI Standard 53 for the effective reduction of arsenic (trivalent and pentavalent) when following an RO and against CSA B483.1.
The Aqua-Cleer Advanced Drinking Water System with Mineral Boost cartridge has been tested and certified by NSF International against NSF/ANSI 42, NSF 372 and CSA B483.1 for material safety and structural integrity only.
Refer to your Installation and Operating Instructions and printed limited Warranties for more specific product information. To avoid contamination from improper handling and installation, your system should only be installed and serviced by your Culligan Man. Performance will vary based on local water conditions.
The substances reduced by these systems are not necessarily in your water.
To maintain product certification and ensure uniform performance, the product is retested on a consistent basis.
1 Reduction claims and capacity not applicable when used as a prefilter to the Aqua-Cleer RO system.
2 NSF/ANSI Standard 401 are considered incidental contaminants and emerging compounds.
3 The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 58
The following Aqua-Cleer Advanced Drinking Water System models are registered for sale with the State of California and/or the State of Iowa.
Model
Aqua-Cleer Advanced Drinking Water System with RO30 with a
2 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30 with a
3 gallon tank
Registration Number
California Iowa
1954 20526
1928 20526
01020485 20
21 01020485
Model
Aqua-Cleer Advanced Drinking Water System with RO30 with a
9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30 and
TD catridge with a 2 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30 and
TD catridge with a 3 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30 and
TD catridge with a 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with TD catridge with a 2 gallon tank
Aqua-Cleer Advanced Drinking Water System with a TD catridge with a 3 gallon tank
Aqua-Cleer Advanced Drinking Water System with TD catridge with a 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30 and
AS3 catridge with a 2 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30 and
AS3 catridge with a 3 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30 and
AS3 catridge with a 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30, TD cartridge and AS3 catridge with a 2 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30, TD cartridge and AS3 catridge with a 3 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30, TD cartridge and AS3 catridge with a 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30 and
PER catridge with a 2, 3 or 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO30, TD cartridge and PER catridge with a 2, 3 or 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO50 with a
2, 3 or 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO50 and
TD catridge with a 2, 3 or 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO50 and
AS3 catridge with a 2, 3 or 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO50, TD cartridge and AS3 catridge with a 2, 3 or 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO50 and
PER catridge with a 2, 3 or 9 gallon tank
Aqua-Cleer Advanced Drinking Water System with RO50, TD cartridge and PER catridge with a 2, 3 or 9 gallon tank
Registration Number
California Iowa
1955
1958
1944
1959
1956
1947
1957
1960
1948
1961
1962
1949
1963
Not Available for
Sale
Not Available for
Sale
Not Available for
Sale
Not Available for
Sale
Not Available for
Sale
Not Available for
Sale
Not Available for
Sale
Not Available for
Sale
20526
20527
20527
20527
20530
20530
20530
20531
20531
20531
20532
20532
20532
20533
20534
20528
20529
20535
20536
20537
20538
Arsenic (abbreviated As) is found naturally in some well water. Arsenic in water has no color, taste or odor. It must be measured by a lab test. Public water utilities must have their water tested for arsenic. You can get the results from your water utility. If you have your own well, you can have the water tested. The local health department or the state environmental health agency can provide a list of certified labs. The cost is typically $15 - $30. Information about arsenic in water can be found on the internet at the US
Environmental Protection Agency website: www.epa.gov/safewater/arsenic.html.
There are two forms of arsenic: pentavalent arsenic (also called As (v), As (+5), and arsenate) and trivalent arsenic (also called As (III), As (+3), and arsenite). In well water, arsenic may be pentavalent, trivalent, or a combination of both. Special sampling procedures are needed for a lab to determine what type and how much of each type of arsenic is in the water. Check with the labs in your area to see if they can provide this type of service.
Reverse osmosis (RO) water treatment systems do not remove trivalent arsenic from water very well. RO systems are very effective at removing pentavalent arsenic. A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic. Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic. A combined chlorine residual
(also called chloramine) may not convert all the trivalent arsenic. If you get water from a public water utility, contact the utility to find out if free chlorine or combined chlorine is used in the water system.
The Aqua-Cleer system is designed to remove pentavalent arsenic. It will not convert trivalent arsenic to pentavalent arsenic. The system was tested in a lab. Under those conditions, the system reduced 0.050 mg/L (ppm) pentavalent arsenic to 0.010 mg/L (ppm) (the USEPA standard for drinking water) or less.
The performance of the system may be different at your installation. Have the treated water tested for arsenic to check if the system is working properly.
The RO component of the Aqua-Cleer system must be replaced every 3-5 years to ensure the system will continue to remove pentavalent arsenic. The component identification and locations where you can purchase the component are listed in the installation/operation manual.
The system has been tested for the treatment of water containing pentavalent arsenic (also known as As
(V), As (III), or arsenate) at concentrations of 0.050 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Fact section of the Performance data
Sheet for further information.
Arsenic (As) is a naturally occurring contaminant found in many ground waters. It generally occurs in two forms (valences or oxidation states): pentavalent arsenic (also known as As(V), As(+5), and arsenate) and trivalent arsenic (also known as As(III), As(+3), and arsenite). In natural ground water, arsenic may exist as trivalent arsenic, pentavalent arsenic, or a combination of both. More information about arsenic and its toxicity can be found at the Agency for Toxic Substances and Disease Registry Toxicological Profile on Arsenic website at http://www.atsdr.cdc.gov/toxprofiles/phs2.html, and at the U.S. Environmental
Protection Agency website at http://www.epa.gov/safewater/arsenic.html.
Arsenic does not generally impart color, taste, or smell to water; therefore, it can only be detected by a chemical analytical test. Public water supplies are required to monitor delivered water for arsenic (trivalent arsenic plus pentavalent arsenic) and the results are available to the public from the utility. Consumers using private water sources will need to make arrangements for testing. An arsenic test usually costs about
$15-30, and it is recommended that the test be conducted by a certified laboratory. Local health departments or environmental protection agencies can help provide consumers with a list of certified laboratories. Some laboratories may also be able to analyze specifically for (speciate) the form(s) of arsenic present in a water sample if requested.
The Aqua-Cleer system with AS3 following an RO is designed to reduce arsenic: both pentavalent and trivalent forms of arsenic. This treatment system was tested under laboratory condition as defined in NSF/
ANSI 53 Drinking Water Treatment Units - Health Effects and was found to reduce [influent arsenic challenge concentration 0.050 mg/L] arsenic consisting of either pentavalent or trivalent arsenic in the test
Arsenic
Fact Sheet
01020485 22
23 01020485 water to less than 0.010 mg/L, for [tested treatment capacity] gallons of delivered water, the life of the system under standard testing conditions. Actual performance of the system may vary depending on specific water quality conditions at the consumer’s installation. Following installation of this system, the consumer should have the treated water tested for arsenic to verify that arsenic reduction is being achieved and the system is functioning properly.
The arsenic removal component of this system must be replace at the end of its useful life of 1,000 gallons.
The replacement components, AS3, RO30, RO50, RO75 can be purchased from your local Culligan dealer.
Symptom
Water Volume and Quality
Condition
No product water Water supply is turned OFF
Catridge or bypass plug is not in place
Not enough product water Low water pressure
Action
Turn water ON
Make sure every cartridge position is filled
Check source water line pressure
System does not shut off
No drain water when system is on
Water has offensive taste and/or odor
Inlet water supply valve is blocked Clear restriction
Storage tank valve is closed Open storage tank valve
Storage tank is depleted
Clogged pre-filter cartridge(s)
Storage tank air pressure charge is low
Increase product water storage capacity and/or install membrane with higher output rating
Replace pre-filter cartridge(s)
Empty water from storage tank (product water faucet must remain open while adjusting pressure) and adjust pressure to 55 kPa (8 psig) shut-off valve is not closing
Clogged flow control
Carbon post-filter is depleted
Membrane depleted or fouled
Sanitizer not flushed out
Contact your Culligan ® dealer
Replace flow control (Item 6) in parts list and contact your Culligan ® dealer
Drain storage tank, sanitize system, and replace carbon post-filter cartridge
Quality Monitor reads yellow or if
TDS test is unsatisfactory, drain sotrage tank, sanitize system, and replace membrane
Drain storage tank and let it refill overnight
Symptom
Leak at fitting
Leakage
Probable Cause
Tubing not pushed completely into fitting
Defective tube
Solution
Push tube into fitting past O-ring seal
Tubing makes a too-tight bend near fitting
Leak at filter housings O-ring has not seated properly
Leak from air ap in faucet
O-ring has nicks or scratches
Restricted drain tube
Tubing from air gap to drain is routed incorrectly
Cut damaged area from tube or replace tube
Run the tubing to reduce the bend
Remove O-ring and inspect O-ring groove for debris. Clean groove, lubricate, and reset O-ring
Replace O-ring
Clear restriction
Reroute tubing so tubing run vertically with no sharp bends or loops
Troubleshooting
Guide
01020485 24
25 01020485
Quality Monitor Status Indications and Common Solutions
Indication
Green Light
Amber Light
No Monitor lights
Leakage
Condition
System operating manually
Action
None
Membrane exhausted Replace membrane
Light assembly is not connected Plug connector into phone jack
Battery voltage low
Battery is not connected
Replace battery
Connect battery
Model
Date Installed
For Service Call Culligan at:
Serial No.
Date
Serviced
Cartridge(s) Changed
Sediment
Filter
Activated
Pre-Carbon
Filter
RO
Membrane
Activated
Post-Carbon
Filter
Sanitized Specialty
Cartridge
Service Log
01020485 26
Culligan
Lifetime
Limited
Warranty
Culligan Aqua-Cleer Advanced Drinking Water System
You have just purchased one of the finest drinking water systems made. As an expression of our confidence in Culligan products, your drinking water system is warranted to the original end-user, when installed in accordance with Culligan International Company specifications, against defects in material and workmanship from the date of original installation, as follows:
For the LIFETIME of the original end-user
The entire reverse osmosis water conditioning unit, EXCLUDING THE
EXPENDABLE FILTER CARTRIDGES AND REVERSE OSMOSIS MEM-
BRANE FILTER USED IN THE UNIT.
For a period of ONE YEAR The Culligan brand reverse osmosis membrane filter.
If a part described above is found defective within the specified period, you should notify your independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the drinking water system on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. You pay only freight from our factory and local dealer charges.
Damage caused by accident, fire, flood, freezing, Act of God, misuse, misapplication, neglect, alteration, installation or operation contrary to our printed instructions, or by the use of accessories or components which do not meet Culligan specifications, is not covered by this warranty.
Our product performance specifications are furnished with each drinking water system. TO THE EX-
TENT PERMITTED BY LAW, CULLIGAN DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING, WITHOUT
LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE; TO THE
EXTENT REQUIRED BY LAW, ANY SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE
ONE-YEAR PERIOD SPECIFIED ABOVE FOR THE PARTS DESCRIBED IN THIS LIMITED WARRANTY. As manufacturer, we do not know the characteristics of your water supply or the purpose for which you are purchasing a drinking water system. Please understand that the quality of water supplies may vary seasonally or over a period of time, and that your water usage rate may vary as well. Water characteristics can also change considerably if your drinking water system is moved to a new location. For these reasons, we assume no liability for the determination of the proper equipment necessary to meet your requirements, and we do not authorize others to assume such obligations for us. Further, we assume no liability and extend no warranties, express or implied, for the use of this product on a non-potable water source.
OUR OBLIGATIONS UNDER THIS WARRANTY ARE LIMITED TO THE REPAIR OR REPLACEMENT OF THE
FAILED PARTS OF THE DRINKING WATER SYSTEM, AND WE ASSUME NO LIABILITY WHATSOEVER
FOR DIRECT, INCIDENTAL, CONSEQUENTIAL, SPECIAL, GENERAL, OR OTHER DAMAGES, WHETHER
FROM CORROSION OR OTHER CAUSES.
CONSUMERS:
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Similarly, some states do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Consult your telephone directory for your local independently-operated Culligan dealer, or write Culligan International Company, for warranty and service information.
Culligan International Company
9399 W. Higgins Road, Suite 1100
Rosemont, Illinois 60018 www.culligan.com
27 01020485