AEM 30-3437 Series 2 AEMnet Adapter Instructions
AEM 30-3437 is an adapter harness that allows you to connect your Series 2 EMS to the AEMnet network. AEMnet is an open architecture software and hardware interface based on the CAN 2.0 specification, which provides the ability for multiple AEMnet enabled devices to easily communicate with each other through a single cable.
With the AEM 30-3437 adapter harness installed, your Series 2 EMS will be able to send and receive data on the AEMnet network. This allows you to connect your Series 2 EMS to other AEMnet enabled devices, such as the AQ-1 Data Logger, the 4-Channel Wideband UEGO Controller, and the Dyno Shaft On-Vehicle Dynamometer.
Advertisement
Advertisement
Instruction Manual
P/N 30-3437 AEMnet Adapter Harness Installation for Series 2 EMS 30-6610 & 30-6611
AEMnet
AEMnet is an open architecture software and hardware interface based on the CAN 2.0 specification, which provides the ability for multiple AEMnet enabled devices to easily communicate with each other through a single cable. The hardware connection is made through a Deutsch 4P DTM connector.
Devices connected to the AEMnet transmit data through this one connection. Once the AEMnet adapter is installed, the Series 2 EMS will be able to send and receive data on the AEMnet.
Instructions for configuring the Series 2 EMS to output data are included in this manual. Instructions on configuring the Series 2 EMS to receive data from other AEMnet enabled products are contained in the individual product manuals. Upon completion of these instructions, the Series 2 EMS will be configured to output data to an AQ1 Data Logger or other data receiving device.
The following AEM products are currently AEMnet enabled:
Series 2 Engine Management System
EMS-4 Universal Standalone Engine Management System
4-Channel Wideband UEGO Controller
AQ-1 Data Logger
Dyno Shaft On-Vehicle Dynamometer
AEM Performance Electronics
2205 W 126 th
Street Unit A, Hawthorne, CA 90250
Phone: (310) 484-2322 Fax: (310) 484-0152 http://www.aemelectronics.com/
Instruction Part Number: 10-3437 Rev 1
2011 AEM Performance Electronics, Inc.
Page 1
AEMnet CONNECTORS
The AEMnet has four wires, two are for communication (white pin 1 and green pin 2) and two are for powering (red pin 3 and black pin 4) certain AEMnet devices. Only the two communication wires
(white pin 1 and green pin 2) are needed for the Series 2 EMS to send/receive data as the EMS is not powered by AEMnet. The red and black wires will need to be connected when using the Series 2
EMS with devices that are powered by AEMnet such as the Dyno-Shaft (see individual instructions for details). The AEMnet connectors are shown below in figure 1. See table 1 for the AEMnet connection pinout.
Figure 1: AEMnet connectors, wire entry view
AEMnet Connector
Pin 1
Pin 2
White
Green
Pin 3
Pin 4
Red
Black
Series 2 EMS Connector
CAN1H
CAN1L
AEMnet Power (switched 12 volts)
AEMnet Ground
Table 1: AEMnet connector pinout
Page 2
REMOVE EXISTING WIRES FROM ECU PLUG(S)
1. Locate a small screwdriver (a precision 1.5mm wide flathead screwdriver is recommended) and carefully pry gray plastic retainer using the three slots in the retainer so it disengages vertically about 1mm as shown in figures 2 and 3:
Figure 2: Pry in these areas
1mm
Figure 3: Lock that has to move up
Page 3
2. Next remove the pin from the plastic connector by lightly prying on the plastic tab that secure the pin in the plastic connector while gently pulling on the wire at the same time as shown in figures 4 and 5.
Figure 4: Pry this tab up with the screwdriver or paper clip to release pin
Figure 5: While prying tab, gently pull wire back
Page 4
3. If the screwdriver does not fit in the area of the plug, a ground paper clip can be used to release the tabs of the plug as shown in figure 6.
Figure 6: Grind a paper clip like this
INSTALL AEMNET ADAPTER HARNESS
4. Table 2 below lists the corresponding CAN1L and CAN1H pin locations for each Series 2
EMS.
CAN1L (Green wire) CAN1H (White wire)
EMS
Adapter p/n
LOCATION LOCATION
30-6610 30-3437 12 69
30-6611 30-3437 12 69
Table 2: CAN1L and CAN1H pin locations
Figure 7 shows the connector for the 6610 and 6611 EMSs.
Figure 7: Wire-side view of pinout for 6610 and 6611 EMS
Page 5
5. To install the harness into the ECU plug, align the CANL and CANH pins into the receptacle of the plug and push in until it clicks as shown in figure 8:
Figure 8: Pushing pin into ECU plug
6. Push the pin lock back into place until it is flush with the ECU plug as shown in figure 9:
Figure 9: Ensure pin lock is relocked
Page 6
CONFIGURING THE SERIES 2 EMS
The AEMnet data stream is compatible with version AEM25 01v23 firmware and later. To activate the AEMnet data stream, open AEMTuner and go to Wizards > Setup Wizard and select the AEMnet Data Stream. See figure 10 below.
Figure 10: Selecting the AEMnet Datastream
With the AEMnet enabled, the Series 2 EMS broadcasts information as shown below in figure
11.
Figure 11: AEMnet Data
Page 7
WARRANTY
12 MONTH LIMITED WARRANTY
Advanced Engine Management Inc. warrants to the consumer that all AEM High Performance products will be free from defects in material and workmanship for a period of twelve (12) months from date of the original purchase. Products that fail within this 12-month warranty period will be repaired or replaced at AEM’s option, when determined by AEM that the product failed due to defects in material or workmanship. This warranty is limited to the repair or replacement of the AEM part. In no event shall this warranty exceed the original purchase price of the AEM part nor shall AEM be responsible for special, incidental or consequential damages or cost incurred due to the failure of this product. Warranty claims to AEM must be transportation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is nontransferable. All implied warranties shall be limited in duration to the said 12 month warranty period. Improper use or installation, accident, abuse, unauthorized repairs or alterations voids this warranty. AEM disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by AEM. Warranty returns will only be accepted by AEM when accompanied by a valid Return Goods
Authorization (RGA) number. Product must be received by AEM within 30 days of the date the RGA is issued.
Please note that before AEM can issue an RGA for any product, it is first necessary for the installer or end user to contact the AEM Performance
Electronics tech line at 1-800-423-0046 to discuss the problem. Most issues can be resolved over the phone. Under no circumstances should a system be returned or a RGA requested before the above process transpires.
Need additional help? Contact the AEM Performance Electronics tech department at
1-800-423-0046 or [email protected], or visit the AEM Performance Electronics forum at http://forum.aempower.com/forum/
Page 8