Amana ANX13 Air Conditioner User manual

Add to my manuals
28 Pages

advertisement

Amana ANX13 Air Conditioner User manual | Manualzz
ANX13
Energy-Efficient
Split System Air Conditioner
Up to 14 SEER / 12 EER
Cooling Capacity: 17,800 - 56,500 BTU/h
Contents
Nomenclature......................................... 2
Product Specifications............................ 3
Expanded Cooling Data.......................... 4
Dimensions........................................... 24
Wiring Diagrams .................................. 25
Accessories........................................... 28
Standard Features
Cabinet Features
•
•
•
•
•
• Heavy-gauge galvanized-steel cabinet
with louvered sound control top
• Steel louver coil guard
• Attractive Architectural Gray powder-paint
finish with 500-hour salt-spray approval
• Top and side maintenance access
• Single-panel access to controls with space
provided for field-installed accessories
Energy-efficient compressor
Single-speed ECM condenser fan motor
Factory-installed filter drier
Copper tube/aluminum fin coil
Service valves with sweat connections
and easy-access gauge ports
• Contactor with lug connection
• Ground lug connection
• AHRI Certified; ETL Listed
* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the 2-Year Unit
Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60
days of installation. Online registration is not required in California or Quebec.
SS-ANX13
www.amana-hac.com
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.
2/20
Supersedes 12/19
.
Nomenclature
A
N
X
13
036
1
AA
1
2
3
4,5
6,7,8
9
10,11
Brand
A
Engineering *
Amana® Brand
Major/ Minor Revisions
* Not used for order or inventory control.
Product Category
S
Electrical
Split System
N Nominal Split System
1 - 208/230 V, 1 Phase, 60 Hz
Unit Type
Nominal Capacity
X
Condenser R-410A
018
1½ Tons
042 3½ Tons
Z
Heat Pump R-410A
024
2 Tons
048 4 Tons
030
2½ Tons
060 5 Tons
036
3 Tons
061 5 Tons
(high capacity)
Efficiency
2
13 13 SEER
16
16 SEER
14 14 SEER
18
18 SEER
www.amana-hac.com
SS-ANX13
Product Specifications
ANX13
0181A*
ANX13
0181B*
ANX13
0241A*
ANX13
0241B*
ANX13
0301A*
ANX13
0301B*
ANX13
0361A*
ANX13
0421A*
ANX13
0481A*
ANX13
0601A*
ANX13
0611A*
Nominal Cooling (BTU/h)
17,800
17,800
23,000
23,000
28,400
28,400
33,600
40,000
46,000
57,000
56,500
SEER / EER
13 / 11
13 / 11
13 / 11
13 / 11
13 / 11
13 / 11
13 / 11
13 / 11
13 / 11
13 / 11
13 / 11
75
72
71
75
73
74
74
75
76
77
77
Capacities
Decibels
Compressor
RLA
9.0
6.0
13.5
7.7
12.8
10.5
14.1
17.9
19.9
25
26.4
LRA
48
37.5
58.3
37
64
47
77
112
109
134
134
Horsepower
1/8
1/8
1/8
1/8
1/8
1/8
1/4
1/4
1/4
1/4
1/4
FLA
0.7
0.7
0.7
0.65
0.65
0.7
1.2
1.2
1.2
1.2
1.3
Liquid Line Size (“O.D.)
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
Suction Line Size (“O.D.)
¾"
¾"
¾"
¾"
¾"
¾"
⅞"
1⅛"
1⅛"
1⅛"
1⅛"
Liquid Valve Size (“O.D.)
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
⅜"
Suction Valve Size (“O.D.) ⁴ ⁵
¾"
¾"
¾"
¾"
¾"
¾"
¾" ³
⅞" ⁴
⅞" ⁴
⅞" ⁴
⅞" 4
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Condenser Fan Motor
Refrigeration System
Refrigerant Line Size ¹
Refrigerant Connection Size
Valve Type
Refrigerant Charge
Shipped with Orifice Size
69
63
63
60
60
68
62
80
91
94
111
0.051
0.052
0.057
0.055
0.065
0.067
0.071
0.074
0.078
0.088
0.086
Electrical Data
Voltage/ Phase (60 Hz)
Minimum Circuit Ampacity ²
208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1 208/230-60 208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1
12
8.2
17.8
10.3
16.7
13.8
18.8
23.6
26.1
32.5
34.3
Max. Overcurrent Protection ³
20 amps
15 amps
30 amps
15 amps
25 amps
20
30 amps
40 amps
45 amps
50 amps
60 amps
Min / Max Volts
197/253
197/253
197/253
197/253
197/253
197/253
197/253
197/253
197/253
197/253
197/253
Electrical Conduit Size
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
½" or ¾"
145
141
145
120
134
153
157
206
225
209
231
Ship Weight (lbs)
¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with AHRI Standard 210/240. For other line-set lengths or sizes, refer to the installation and
Operating instructions and/or the long line-set guidelines.
² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
⁴ Installer will need to supply ¾” to ⅞” adapters for suction line connections.
⁵ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
•
This product may not be installed in the Southeast (including Hawaii) or Southwest Regions as of Jan. 1, 2015.
SS-ANX13
www.amana-hac.com
3
4
www.amana-hac.com
675
600
525
675
600
525
16.1
0.77
22
1.27
4.7
216
103
17.4
0.79
21
1.30
4.9
222
106
17.9
0.83
20
1.31
4.9
225
107
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
59
15.8
0.67
19
1.26
4.7
214
101
17.1
0.70
18
1.29
4.8
220
105
17.6
0.73
18
1.30
4.9
222
106
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
Airflow
63
16.5
0.68
20
1.30
4.9
232
109
17.9
0.71
20
1.33
5.0
239
112
18.5
0.74
19
1.34
5.0
242
114
16.4
0.56
16
1.29
4.8
230
108
17.7
0.58
16
1.32
4.9
237
111
18.3
0.61
15
1.33
5.0
239
112
67
17.9
0.52
16
1.33
5.0
245
119
19.4
0.54
16
1.36
5.1
253
123
20.0
0.56
15
1.38
5.2
255
124
17.9
0.39
12
1.33
5.0
243
118
19.4
0.40
12
1.35
5.1
250
122
20.0
0.42
12
1.36
5.1
253
123
19.2
0.33
11
1.37
5.2
256
127
20.8
0.35
11
1.41
5.3
264
131
21.5
0.36
11
1.42
5.4
266
132
-
71
15.7
0.79
22
1.36
5.1
242
108
17.0
0.82
21
1.39
5.3
250
112
17.5
0.86
21
1.40
5.3
252
113
59
15.4
0.70
19
1.35
5.1
240
107
16.7
0.72
19
1.38
5.2
247
111
17.2
0.76
18
1.39
5.3
249
112
63
16.2
0.71
20
1.39
5.2
260
115
17.5
0.74
20
1.42
5.4
269
119
18.0
0.77
19
1.43
5.4
271
120
16.0
0.58
16
1.38
5.2
258
114
17.3
0.60
16
1.41
5.3
266
118
17.9
0.63
15
1.42
5.4
268
119
67
17.5
0.54
16
1.43
5.4
275
126
19.0
0.56
16
1.46
5.5
284
130
19.5
0.58
16
1.47
5.6
286
131
17.5
0.40
12
1.42
5.4
272
125
19.0
0.42
12
1.45
5.5
281
128
19.6
0.44
12
1.46
5.5
283
130
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
18.8
0.35
11
1.47
5.6
287
134
20.3
0.36
11
1.51
5.7
296
138
21.0
0.38
11
1.52
5.8
299
139
-
71
63
15.8
0.73
20
1.47
5.7
296
120
17.1
0.75
20
1.50
5.8
305
123
17.6
0.79
19
1.51
5.9
308
125
15.6
0.60
16
1.46
5.6
293
119
16.9
0.62
16
1.49
5.8
302
122
17.4
0.65
15
1.50
5.8
305
123
67
17.1
0.55
16
1.51
5.9
313
131
18.5
0.57
16
1.55
6.0
322
135
19.1
0.60
16
1.56
6.1
326
136
17.1
0.41
12
1.50
5.8
310
129
18.5
0.43
12
1.54
6.0
319
133
19.1
0.45
12
1.55
6.0
322
135
18.3
0.35
11
1.56
6.1
326
139
19.9
0.37
11
1.60
6.2
336
144
20.5
0.39
11
1.61
6.3
340
145
-
71
59
15.0
0.84
22
1.51
5.9
314
118
16.2
0.87
22
1.54
6.1
323
122
16.7
0.91
21
1.56
6.1
326
123
14.7
0.74
19
1.50
5.9
310
117
15.9
0.77
19
1.53
6.0
320
121
16.4
0.80
18
1.54
6.1
323
122
Shaded area reflects ACCA (TVA) conditions
15.3
0.81
22
1.44
5.5
275
113
16.6
0.84
21
1.47
5.7
284
116
17.1
0.88
21
1.48
5.7
287
117
59
15.1
0.72
19
1.43
5.5
272
111
16.3
0.74
19
1.46
5.6
281
115
16.8
0.78
18
1.47
5.7
284
116
63
15.4
0.75
20
1.54
6.1
337
126
16.7
0.78
20
1.58
6.2
348
130
17.2
0.82
19
1.59
6.3
351
131
15.2
0.62
16
1.53
6.0
334
125
16.5
0.64
16
1.56
6.2
344
128
17.0
0.67
16
1.58
6.2
348
130
67
16.7
0.57
17
1.59
6.2
356
137
18.1
0.59
16
1.62
6.4
367
142
18.6
0.62
16
1.64
6.5
371
143
16.7
0.43
12
1.57
6.2
353
136
18.1
0.44
12
1.61
6.4
364
140
18.6
0.46
12
1.62
6.4
367
142
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
17.9
0.37
11
1.63
6.5
372
146
19.4
0.38
11
1.67
6.7
383
151
20.0
0.40
11
1.69
6.7
387
152
-
71
14.2
0.87
22
1.57
6.3
353
124
15.4
0.90
21
1.60
6.5
364
128
15.9
0.95
20
1.62
6.5
367
129
59
14.0
0.77
19
1.55
6.2
349
123
15.1
0.80
18
1.59
6.4
360
126
15.6
0.83
18
1.60
6.5
364
128
14.6
0.78
20
1.60
6.4
380
132
15.8
0.81
20
1.64
6.6
391
136
16.3
0.85
19
1.65
6.7
395
137
63
14.5
0.64
16
1.59
6.4
376
130
15.7
0.66
16
1.62
6.6
387
135
16.2
0.70
15
1.64
6.6
391
136
15.8
0.59
16
1.65
6.6
401
144
17.2
0.61
16
1.69
6.8
413
148
17.7
0.64
15
1.70
6.9
417
150
67
15.9
0.44
12
1.64
6.6
397
142
17.2
0.46
12
1.67
6.8
409
147
17.7
0.48
12
1.69
6.8
413
148
105ºF
13.2
0.88
20
1.62
6.6
390
128
14.3
0.91
20
1.66
6.8
402
132
14.7
0.96
19
1.67
6.9
406
133
59
12.9
0.77
18
1.60
6.6
386
127
14.0
0.80
17
1.64
6.8
398
131
14.4
0.84
17
1.66
6.8
402
132
13.5
0.79
19
1.65
6.8
419
136
14.7
0.82
18
1.69
7.0
432
141
15.1
0.85
18
1.70
7.1
437
142
63
13.4
0.65
15
1.64
6.7
415
135
14.5
0.67
15
1.68
6.9
428
139
15.0
0.70
14
1.69
7.0
432
141
14.7
0.59
15
1.70
7.0
443
149
15.9
0.62
15
1.74
7.2
457
153
16.4
0.65
14
1.76
7.3
461
155
67
14.7
0.45
12
1.69
7.0
438
147
15.9
0.46
11
1.73
7.2
452
152
16.4
0.49
11
1.74
7.2
456
153
15.7
0.38
11
1.76
7.3
462
159
17.1
0.40
10
1.80
7.5
476
163
17.6
0.42
10
1.81
7.6
481
165
-
71
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
17.0
0.38
11
1.70
6.9
418
153
18.4
0.39
11
1.74
7.1
431
158
19.0
0.41
11
1.75
7.1
435
160
-
71
115ºF
Expanded Cooling Data — ANX130181A* / CA*F1824*D6*+EEP
SS-ANX13
SS-ANX13
www.amana-hac.com
675
600
525
675
600
525
16.6
0.88
26
1.29
4.8
220
105
18.0
0.91
25
1.32
5.0
227
108
18.6
0.96
24
1.33
5.0
229
109
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
59
16.4
0.84
24
1.28
4.8
218
104
17.7
0.87
24
1.31
4.9
225
107
18.3
0.91
23
1.32
5.0
227
108
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
Airflow
63
17.0
0.85
25
1.32
4.9
237
111
18.4
0.88
25
1.35
5.1
244
115
18.9
0.92
24
1.36
5.1
247
116
16.7
0.79
23
1.31
4.9
234
110
18.1
0.82
23
1.34
5.0
242
114
18.7
0.86
22
1.35
5.1
244
115
67
17.8
0.77
24
1.35
5.1
250
121
19.3
0.79
23
1.39
5.2
258
125
19.8
0.83
23
1.40
5.3
260
126
17.9
0.64
20
1.34
5.0
248
120
19.4
0.66
20
1.38
5.2
255
124
19.9
0.70
19
1.39
5.2
258
125
19.0
0.62
21
1.39
5.3
261
129
20.5
0.64
20
1.43
5.4
269
133
21.2
0.68
19
1.44
5.5
272
135
71
19.1
0.5
16
1.4
5.2
258.2
128.1
20.7
0.5
16
1.4
5.4
266.2
132.0
21.3
0.5
15
1.4
5.4
268.9
133.4
16.3
0.91
26
1.38
5.2
247
110
17.6
0.95
26
1.41
5.3
255
114
18.1
0.99
25
1.42
5.4
257
115
59
16.0
0.87
24
1.37
5.2
244
109
17.3
0.90
24
1.40
5.3
252
113
17.8
0.95
23
1.41
5.3
255
114
63
16.6
0.88
26
1.41
5.3
266
118
18.0
0.91
25
1.44
5.5
274
121
18.5
0.96
24
1.45
5.5
277
122
16.3
0.82
23
1.40
5.3
263
116
17.7
0.85
23
1.43
5.4
271
120
18.2
0.89
22
1.44
5.5
274
121
67
17.4
0.79
24
1.45
5.5
281
128
18.8
0.82
24
1.48
5.6
289
132
19.4
0.86
23
1.50
5.7
292
134
17.4
0.66
20
1.44
5.4
278
127
18.9
0.69
20
1.47
5.6
286
131
19.5
0.72
19
1.48
5.6
289
132
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
18.5
0.64
21
1.49
5.7
293
137
20.1
0.67
21
1.53
5.9
302
141
20.7
0.70
20
1.54
5.9
305
142
71
18.6
0.50
16
1.48
5.6
290
135
20.2
0.51
16
1.52
5.8
299
140
20.8
0.54
15
1.53
5.9
302
141
63
16.2
0.90
26
1.49
5.8
302
122
17.5
0.94
25
1.53
5.9
312
126
18.1
0.98
24
1.54
6.0
315
127
15.9
0.84
23
1.48
5.7
299
121
17.3
0.87
23
1.51
5.9
308
125
17.8
0.91
22
1.53
5.9
312
126
67
16.9
0.81
24
1.54
6.0
319
133
18.4
0.84
24
1.57
6.1
329
137
18.9
0.89
23
1.58
6.2
332
139
17.0
0.68
20
1.52
5.9
316
132
18.5
0.71
20
1.56
6.1
326
136
19.0
0.74
19
1.57
6.1
329
137
71
18.1
0.66
21
1.58
6.2
333
142
19.6
0.69
21
1.62
6.4
343
146
20.2
0.72
20
1.63
6.4
347
148
18.2
0.5
16
1.6
6.1
329.6
140.6
19.7
0.5
16
1.6
6.3
339.7
145.0
20.3
0.6
15
1.6
6.4
343.1
146.4
Shaded area reflects AHRI conditions
15.9
0.94
26
1.46
5.6
281
115
17.2
0.97
26
1.50
5.8
290
118
17.7
1.00
24
1.51
5.8
292
120
59
15.6
0.89
24
1.45
5.6
278
114
16.9
0.93
24
1.48
5.7
287
117
17.4
0.97
23
1.50
5.8
290
118
59
15.5
0.97
26
1.53
6.0
320
121
16.8
1.00
26
1.57
6.2
330
124
17.3
1.00
24
1.58
6.2
333
126
15.2
0.92
25
1.52
6.0
317
119
16.5
0.96
24
1.56
6.1
326
123
17.0
1.00
23
1.57
6.2
330
124
63
15.8
0.93
26
1.56
6.2
344
128
17.1
0.97
25
1.60
6.3
355
132
17.6
1.00
24
1.61
6.4
358
134
15.6
0.86
24
1.55
6.1
341
127
16.8
0.90
23
1.59
6.3
351
131
17.4
0.94
22
1.60
6.3
355
132
67
16.5
0.84
24
1.61
6.4
363
140
17.9
0.87
24
1.65
6.5
375
144
18.4
0.91
23
1.66
6.6
378
146
16.6
0.70
20
1.60
6.3
360
139
18.0
0.73
20
1.64
6.5
371
143
18.5
0.76
19
1.65
6.5
375
144
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
17.6
0.68
21
1.66
6.6
379
149
19.1
0.71
21
1.70
6.8
391
154
19.7
0.74
20
1.71
6.8
395
155
71
17.8
0.53
16
1.65
6.5
375
148
19.2
0.54
16
1.69
6.7
387
152
19.8
0.57
15
1.70
6.8
391
154
14.7
1.00
26
1.59
6.4
360
126
15.9
1.00
24
1.63
6.6
371
130
16.4
1.00
22
1.64
6.6
375
132
59
14.5
0.96
24
1.58
6.3
356
125
15.7
0.99
24
1.62
6.5
367
129
16.1
1.00
22
1.63
6.6
371
130
15.0
0.97
25
1.62
6.6
387
134
16.2
1.00
25
1.66
6.7
399
139
16.7
1.00
23
1.68
6.8
403
140
63
14.8
0.90
23
1.61
6.5
383
133
16.0
0.93
23
1.65
6.7
395
137
16.5
1.00
22
1.66
6.7
399
139
15.7
0.87
24
1.67
6.8
409
147
17.0
0.90
24
1.71
7.0
422
151
17.5
0.95
23
1.73
7.0
426
153
67
15.8
0.73
20
1.66
6.7
405
145
17.1
0.76
20
1.70
6.9
417
150
17.6
0.79
19
1.71
7.0
422
151
105ºF
13.6
1.00
24
1.64
6.8
398
131
14.8
1.00
23
1.68
7.0
410
135
15.2
1.00
21
1.70
7.0
414
136
59
13.4
0.96
23
1.63
6.7
394
129
14.5
1.00
22
1.67
6.9
406
133
14.9
1.00
20
1.68
7.0
410
135
13.9
0.97
24
1.68
6.9
428
139
15.0
1.00
23
1.72
7.1
441
143
15.5
1.00
21
1.73
7.2
445
145
63
13.7
0.90
22
1.66
6.9
424
138
14.8
0.94
21
1.70
7.1
437
142
15.3
1.00
21
1.72
7.1
441
143
14.5
0.88
22
1.73
7.2
452
152
15.8
0.91
22
1.77
7.4
466
157
16.2
0.96
21
1.79
7.4
470
158
67
14.6
0.74
19
1.72
7.1
447
150
15.8
0.76
19
1.76
7.3
461
155
16.3
0.80
18
1.77
7.4
466
157
15.5
0.71
19
1.78
7.4
471
162
16.8
0.74
19
1.83
7.6
486
167
17.3
0.78
18
1.84
7.7
491
168
71
15.6
0.55
15
1.77
7.4
467
160
16.9
0.57
15
1.81
7.6
481
165
17.4
0.60
14
1.83
7.6
486
167
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
16.8
0.71
21
1.73
7.0
426
156
18.2
0.73
20
1.77
7.2
440
161
18.7
0.77
20
1.78
7.3
444
163
71
16.9
0.5
16
1.7
7.0
422.3
154.8
18.3
0.6
16
1.8
7.2
435.3
159.6
18.8
0.6
15
1.8
7.2
439.7
161.2
115ºF
Expanded Cooling Data — ANX130181A* / CA*F1824*D6*+EEP (cont.)
5
6
www.amana-hac.com
650
600
525
650
600
525
16.4
0.74
21
1.02
4.1
226
112
17.2
0.76
20
1.03
4.1
229
113
17.7
0.77
19
1.04
4.2
233
115
15.9
0.83
23
0.99
4.0
210
105
16.7
0.84
22
1.00
4.0
213
106
17.2
0.86
21
1.02
4.1
216
108
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
63
16.2
0.61
17
1.01
4.0
224
111
17.0
0.62
16
1.02
4.1
227
112
17.6
0.63
16
1.03
4.2
231
114
59
15.6
0.73
20
0.98
3.9
208
104
16.4
0.74
19
1.00
4.0
211
105
16.9
0.76
18
1.01
4.0
214
107
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
Airflow
67
17.7
0.56
18
1.05
4.2
239
122
18.6
0.57
16
1.06
4.3
242
124
19.2
0.58
16
1.08
4.3
246
126
17.7
0.42
13
1.04
4.2
236
121
18.7
0.43
12
1.05
4.2
239
122
19.2
0.44
12
1.07
4.3
243
124
19.0
0.36
12
1.09
4.4
249
130
20.0
0.37
11
1.10
4.4
252
132
20.6
0.38
11
1.12
4.5
257
134
-
71
15.5
0.86
23
1.08
4.3
236
111
16.3
0.88
22
1.09
4.4
239
112
16.8
0.89
21
1.11
4.5
243
114
59
15.3
0.76
20
1.07
4.3
233
110
16.0
0.77
19
1.08
4.3
236
111
16.5
0.79
18
1.10
4.4
240
113
63
16.0
0.77
22
1.10
4.4
253
118
16.8
0.78
20
1.12
4.5
257
120
17.3
0.80
20
1.13
4.6
261
122
15.8
0.63
18
1.09
4.4
251
117
16.6
0.64
16
1.11
4.4
254
118
17.1
0.66
16
1.12
4.5
259
120
67
17.3
0.58
18
1.14
4.6
268
129
18.2
0.59
17
1.16
4.7
271
131
18.7
0.61
16
1.17
4.7
276
133
17.3
0.44
13
1.13
4.5
265
127
18.2
0.45
12
1.15
4.6
269
129
18.8
0.45
12
1.16
4.7
273
131
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
18.6
0.38
12
1.18
4.8
279
137
19.5
0.38
11
1.20
4.8
283
139
20.1
0.39
11
1.22
4.9
288
141
-
71
63
15.6
0.79
22
1.18
4.9
288
123
16.4
0.80
20
1.20
4.9
292
124
16.9
0.82
20
1.21
5.0
297
126
15.4
0.65
18
1.17
4.8
285
121
16.2
0.66
16
1.18
4.9
289
123
16.7
0.67
16
1.20
5.0
294
125
67
16.9
0.60
18
1.22
5.0
304
134
17.8
0.61
17
1.24
5.1
309
136
18.3
0.62
16
1.26
5.2
314
138
16.9
0.45
13
1.21
5.0
301
133
17.8
0.46
13
1.23
5.0
305
134
18.3
0.47
12
1.25
5.1
311
137
18.1
0.38
12
1.27
5.2
318
143
19.1
0.39
11
1.28
5.3
322
144
19.6
0.40
11
1.30
5.4
327
147
-
71
59
14.8
0.91
24
1.22
5.1
305
121
15.5
0.93
22
1.23
5.2
309
123
16.0
0.95
21
1.25
5.2
315
125
14.5
0.80
20
1.21
5.0
302
120
15.3
0.82
19
1.22
5.1
306
121
15.8
0.83
19
1.24
5.2
311
124
Shaded area reflects ACCA (TVA) conditions
15.2
0.88
24
1.15
4.7
268
115
15.9
0.90
22
1.17
4.8
271
117
16.4
0.92
21
1.19
4.9
276
119
59
14.9
0.78
20
1.14
4.7
265
114
15.7
0.79
19
1.16
4.7
269
116
16.1
0.81
18
1.17
4.8
273
118
16.5
0.62
18
1.29
5.4
347
141
17.3
0.63
17
1.31
5.5
351
142
17.9
0.64
16
1.33
5.6
357
145
15.2
0.82
22
1.25
5.2
328
129
16.0
0.83
20
1.26
5.3
333
131
16.5
0.85
20
1.28
5.4
339
133
67
16.5
0.46
13
1.28
5.4
343
139
17.4
0.47
13
1.30
5.4
348
141
17.9
0.48
12
1.32
5.5
354
143
63
15.1
0.67
18
1.24
5.2
325
127
15.8
0.68
17
1.25
5.2
329
129
16.3
0.70
16
1.27
5.3
335
131
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
17.7
0.40
12
1.34
5.6
362
150
18.6
0.40
12
1.36
5.7
366
152
19.2
0.41
11
1.38
5.8
373
154
-
71
14.0
0.95
23
1.28
5.4
343
127
14.8
0.96
22
1.29
5.5
348
129
15.2
0.98
21
1.31
5.6
354
131
59
13.8
0.83
20
1.26
5.4
340
126
14.5
0.85
19
1.28
5.5
344
127
15.0
0.86
18
1.30
5.5
350
129
14.5
0.85
21
1.31
5.6
369
135
15.2
0.86
20
1.32
5.7
374
137
15.7
0.88
20
1.34
5.8
381
139
63
14.3
0.70
17
1.30
5.5
366
134
15.0
0.71
16
1.31
5.6
371
135
15.5
0.72
16
1.33
5.7
377
138
15.7
0.64
18
1.35
5.8
390
147
16.5
0.65
16
1.37
5.9
395
149
17.0
0.66
16
1.39
6.0
402
152
67
15.7
0.48
13
1.34
5.7
386
146
16.5
0.49
12
1.36
5.8
391
148
17.0
0.50
12
1.38
5.9
398
150
105ºF
13.0
0.95
22
1.32
5.8
379
131
13.7
0.97
20
1.34
5.9
384
133
14.1
0.99
20
1.36
6.0
391
135
59
12.8
0.84
19
1.31
5.7
375
130
13.4
0.85
18
1.33
5.8
380
132
13.9
0.87
17
1.35
5.9
387
134
13.4
0.85
20
1.36
5.9
408
140
14.1
0.87
19
1.37
6.0
414
141
14.5
0.89
18
1.40
6.1
421
144
63
13.3
0.70
16
1.34
5.9
404
138
13.9
0.71
15
1.36
6.0
409
140
14.4
0.73
15
1.38
6.1
417
142
14.5
0.65
16
1.41
6.2
431
152
15.2
0.66
15
1.42
6.2
437
154
15.7
0.67
15
1.45
6.3
444
157
67
14.5
0.49
12
1.39
6.1
427
151
15.3
0.49
12
1.41
6.2
432
153
15.7
0.50
11
1.43
6.3
440
156
15.6
0.42
11
1.46
6.4
450
162
16.4
0.42
11
1.48
6.5
456
164
16.9
0.43
10
1.50
6.6
463
167
-
71
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
16.8
0.41
12
1.40
6.0
407
157
17.7
0.42
11
1.42
6.1
412
159
18.2
0.43
11
1.44
6.2
419
162
-
71
115ºF
Expanded Cooling Data — ANX130181B* / CA*F1824*D6*+EEP
SS-ANX13
SS-ANX13
www.amana-hac.com
650
600
525
650
600
525
16.8
0.92
27
1.03
4.2
230
114
17.6
0.94
25
1.05
4.2
234
115
18.2
0.96
25
1.06
4.3
238
117
16.5
0.96
28
1.01
4.0
214
107
17.3
0.97
26
1.02
4.1
217
109
17.8
0.99
25
1.04
4.2
221
110
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
63
16.5
0.86
25
1.02
4.1
228
113
17.4
0.87
23
1.04
4.2
231
114
17.9
0.89
23
1.05
4.2
235
116
59
16.2
0.91
26
1.00
4.0
212
106
17.0
0.93
24
1.01
4.1
215
107
17.5
0.95
24
1.03
4.1
219
109
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
Airflow
67
17.6
0.83
26
1.07
4.3
243
124
18.5
0.85
24
1.08
4.4
247
126
19.0
0.86
23
1.10
4.4
251
128
17.7
0.70
22
1.06
4.3
241
123
18.6
0.71
20
1.07
4.3
244
125
19.1
0.72
20
1.09
4.4
248
127
18.7
0.68
22
1.11
4.5
254
132
19.7
0.69
21
1.12
4.5
257
134
20.3
0.70
20
1.14
4.6
262
137
71
18.9
0.5
17
1.1
4.4
251.0
131.0
19.8
0.5
16
1.1
4.5
255.0
133.0
20.5
0.5
16
1.1
4.6
259.0
135.0
16.1
0.99
28
1.10
4.4
240
113
16.9
1.00
26
1.11
4.5
244
115
17.4
1.00
25
1.13
4.5
248
117
59
15.8
0.95
26
1.09
4.4
238
112
16.6
0.96
24
1.10
4.4
241
114
17.1
1.00
24
1.12
4.5
245
115
63
16.4
0.96
27
1.12
4.5
259
120
17.2
0.97
26
1.14
4.6
262
122
17.8
0.99
25
1.15
4.7
267
124
16.1
0.89
25
1.11
4.5
256
119
17.0
0.90
23
1.13
4.5
259
121
17.5
0.92
23
1.14
4.6
264
123
67
17.2
0.86
26
1.16
4.7
273
131
18.0
0.88
24
1.18
4.7
277
133
18.6
0.89
24
1.20
4.8
282
135
17.3
0.72
22
1.15
4.6
270
130
18.1
0.73
20
1.17
4.7
274
132
18.7
0.75
20
1.19
4.8
279
134
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
18.3
0.70
23
1.21
4.9
285
140
19.2
0.71
21
1.22
4.9
289
142
19.8
0.73
20
1.24
5.0
294
144
71
18.4
0.54
17
1.19
4.8
282
139
19.4
0.55
16
1.21
4.9
286
140
20.0
0.56
16
1.23
5.0
291
143
63
16.0
0.98
28
1.20
5.0
294
125
16.8
1.00
26
1.22
5.0
298
127
17.3
1.00
25
1.24
5.1
303
129
15.8
0.91
25
1.19
4.9
291
124
16.6
0.92
23
1.21
5.0
295
126
17.1
0.94
23
1.23
5.1
300
128
67
16.8
0.88
26
1.25
5.1
311
137
17.6
0.90
24
1.26
5.2
315
138
18.2
0.92
24
1.28
5.3
320
141
16.8
0.74
22
1.23
5.1
308
135
17.7
0.75
20
1.25
5.1
312
137
18.2
0.77
20
1.27
5.2
317
139
71
17.9
0.72
23
1.29
5.3
324
145
18.8
0.73
21
1.31
5.4
328
147
19.4
0.74
20
1.33
5.5
334
150
18.0
0.6
17
1.3
5.3
321.0
144.0
18.9
0.6
16
1.3
5.4
325.0
146.0
19.5
0.6
16
1.3
5.5
331.0
148.0
Shaded area reflects AHRI conditions
15.7
1.00
28
1.17
4.8
273
118
16.5
1.00
25
1.19
4.9
277
119
17.0
1.00
24
1.21
5.0
282
121
59
15.4
0.97
26
1.16
4.8
271
116
16.2
0.98
25
1.18
4.8
274
118
16.7
1.00
24
1.20
4.9
279
120
59
15.3
1.00
27
1.24
5.2
311
124
16.1
1.00
25
1.26
5.3
315
125
16.6
1.00
24
1.28
5.3
321
127
15.0
1.00
26
1.23
5.1
308
122
15.8
1.00
24
1.25
5.2
312
124
16.3
1.00
23
1.27
5.3
318
126
63
15.6
1.00
27
1.27
5.3
335
131
16.4
1.00
25
1.29
5.4
339
133
16.9
1.00
24
1.31
5.5
345
135
15.4
0.94
25
1.26
5.3
332
130
16.2
0.95
24
1.28
5.3
336
132
16.7
1.00
24
1.30
5.4
342
134
67
16.3
0.91
26
1.32
5.5
354
143
17.2
0.93
24
1.33
5.6
358
145
17.7
0.95
24
1.36
5.7
365
148
16.4
0.76
22
1.31
5.5
350
142
17.3
0.78
21
1.32
5.5
355
144
17.8
0.79
20
1.34
5.6
361
146
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
17.4
0.74
23
1.37
5.7
369
153
18.3
0.75
21
1.38
5.8
374
155
18.9
0.77
21
1.41
5.9
380
157
71
17.6
0.57
18
1.35
5.7
365
151
18.5
0.58
16
1.37
5.8
370
153
19.0
0.59
16
1.39
5.9
377
156
14.5
1.00
26
1.30
5.5
350
129
15.3
1.00
23
1.32
5.6
355
131
15.8
1.00
22
1.34
5.7
361
133
59
14.3
1.04
26
1.29
5.5
347
128
15.0
1.00
23
1.30
5.6
351
130
15.5
1.00
22
1.32
5.7
357
132
14.8
1.00
26
1.33
5.7
377
138
15.6
1.00
24
1.35
5.8
382
140
16.1
1.00
23
1.37
5.9
389
142
63
14.6
0.97
25
1.32
5.6
373
136
15.4
0.99
23
1.34
5.7
378
138
15.8
1.00
22
1.36
5.8
385
141
15.5
0.95
26
1.38
5.9
398
150
16.3
0.96
24
1.40
6.0
403
152
16.8
0.98
23
1.42
6.1
410
155
67
15.6
0.79
22
1.37
5.8
394
149
16.4
0.81
20
1.38
5.9
399
151
16.9
0.82
20
1.41
6.0
406
153
105ºF
13.5
1.00
24
1.35
5.9
387
134
14.2
1.00
22
1.37
6.0
392
136
14.6
1.00
21
1.39
6.1
399
138
59
13.2
1.05
24
1.34
5.8
383
133
13.9
1.00
21
1.35
5.9
388
134
14.3
1.00
20
1.37
6.0
395
137
13.7
1.00
24
1.38
6.1
416
142
14.4
1.00
22
1.40
6.1
422
144
14.9
1.00
21
1.42
6.2
429
147
63
13.5
0.98
23
1.37
6.0
412
141
14.2
1.00
22
1.39
6.1
418
143
14.7
1.00
21
1.41
6.2
425
145
14.4
0.96
24
1.43
6.3
440
155
15.1
0.97
23
1.45
6.4
446
158
15.6
0.99
22
1.47
6.5
453
160
67
14.5
0.80
20
1.42
6.2
435
154
15.2
0.81
19
1.44
6.3
441
156
15.7
0.83
18
1.46
6.4
449
159
15.3
0.78
21
1.49
6.5
459
166
16.1
0.79
20
1.50
6.6
465
168
16.6
0.80
19
1.53
6.7
473
171
71
15.5
0.60
16
1.47
6.5
454
164
16.2
0.61
15
1.49
6.6
460
166
16.7
0.62
15
1.51
6.7
468
169
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
16.6
0.77
22
1.43
6.1
415
160
17.4
0.78
21
1.45
6.2
421
162
18.0
0.80
20
1.47
6.3
428
165
71
16.7
0.6
17
1.4
6.1
411.0
159.0
17.5
0.6
16
1.4
6.2
416.0
161.0
18.1
0.6
16
1.5
6.3
424.0
163.0
115ºF
Expanded Cooling Data — ANX130181B* / CA*F1824*D6*+EEP (cont.)
7
8
www.amana-hac.com
900
800
700
900
800
700
20.5
0.78
21
1.62
6.0
225
101
22.3
0.81
21
1.65
6.1
232
104
22.9
0.85
20
1.67
6.2
234
105
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
59
20.2
0.68
18
1.60
5.9
222
100
21.9
0.71
18
1.64
6.1
229
103
22.5
0.74
17
1.65
6.1
231
104
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
Airflow
63
21.1
0.70
19
1.65
6.1
242
108
22.9
0.72
19
1.69
6.3
249
111
23.6
0.76
18
1.70
6.3
252
112
20.9
0.57
16
1.64
6.0
239
106
22.7
0.59
15
1.67
6.2
247
110
23.4
0.62
15
1.69
6.3
249
111
67
22.9
0.53
16
1.70
6.3
255
117
24.8
0.55
16
1.74
6.5
263
121
25.5
0.57
15
1.75
6.5
266
122
22.9
0.40
12
1.68
6.2
253
116
24.8
0.41
12
1.72
6.4
260
120
25.6
0.43
11
1.74
6.5
263
121
24.6
0.34
11
1.75
6.5
266
125
26.6
0.35
11
1.79
6.7
274
129
27.4
0.37
10
1.80
6.8
277
130
-
71
20.1
0.81
21
1.73
6.4
252
107
21.7
0.84
21
1.77
6.6
260
110
22.4
0.88
20
1.79
6.7
262
111
59
19.7
0.71
18
1.72
6.4
249
106
21.4
0.74
18
1.76
6.6
257
109
22.0
0.77
17
1.77
6.6
260
110
63
20.7
0.72
20
1.77
6.6
271
114
22.4
0.75
19
1.81
6.8
280
117
23.0
0.78
18
1.82
6.8
282
118
20.4
0.59
16
1.75
6.5
268
112
22.2
0.61
16
1.79
6.7
277
116
22.8
0.64
15
1.81
6.8
280
117
67
22.4
0.55
16
1.82
6.8
286
124
24.2
0.57
16
1.86
7.0
295
128
24.9
0.59
15
1.88
7.1
298
129
22.4
0.41
12
1.81
6.7
283
123
24.3
0.43
12
1.85
6.9
292
127
25.0
0.45
11
1.86
7.0
295
128
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
24.0
0.35
11
1.88
7.1
299
132
26.0
0.36
11
1.92
7.3
308
136
26.8
0.38
10
1.94
7.3
311
138
-
71
63
20.2
0.74
20
1.87
7.2
308
118
21.8
0.77
19
1.92
7.4
318
122
22.5
0.80
18
1.93
7.4
321
123
20.0
0.61
16
1.86
7.1
305
117
21.6
0.63
16
1.90
7.3
315
120
22.3
0.66
15
1.92
7.4
318
122
67
21.8
0.56
16
1.93
7.4
326
129
23.6
0.58
16
1.98
7.6
336
133
24.4
0.61
15
1.99
7.7
339
134
21.9
0.42
12
1.91
7.3
322
128
23.7
0.44
12
1.96
7.5
332
132
24.4
0.46
11
1.97
7.6
336
133
23.4
0.36
11
1.99
7.7
340
137
25.4
0.37
11
2.04
7.9
350
142
26.1
0.39
10
2.05
8.0
354
143
-
71
59
19.1
0.85
21
1.92
7.5
326
117
20.7
0.89
21
1.97
7.7
337
120
21.3
0.93
20
1.99
7.8
340
121
18.8
0.75
19
1.91
7.4
323
115
20.4
0.78
18
1.95
7.6
333
119
21.0
0.82
17
1.97
7.7
336
120
Shaded area reflects ACCA (TVA) conditions
19.6
0.83
21
1.83
7.0
287
111
21.2
0.86
21
1.88
7.2
295
114
21.9
0.90
20
1.89
7.3
298
116
59
19.3
0.73
18
1.82
6.9
284
110
20.9
0.75
18
1.86
7.1
293
113
21.5
0.79
17
1.88
7.2
295
114
63
19.7
0.76
20
1.96
7.7
351
124
21.3
0.79
19
2.01
7.9
362
128
22.0
0.83
19
2.03
8.0
366
129
19.5
0.63
16
1.95
7.6
348
123
21.1
0.65
16
2.00
7.8
359
127
21.7
0.68
15
2.01
7.9
362
128
67
21.3
0.58
16
2.02
7.9
371
135
23.1
0.60
16
2.07
8.2
382
140
23.8
0.63
15
2.09
8.2
386
141
21.3
0.43
12
2.01
7.8
367
134
23.1
0.45
12
2.06
8.1
379
138
23.8
0.47
11
2.07
8.2
382
140
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
22.9
0.37
11
2.09
8.2
387
144
24.8
0.39
11
2.14
8.5
399
149
25.5
0.40
11
2.16
8.5
403
150
-
71
18.2
0.89
21
2.00
8.0
367
122
19.7
0.92
21
2.05
8.2
379
126
20.3
0.96
20
2.07
8.3
382
127
59
17.8
0.78
18
1.98
7.9
364
121
19.3
0.81
18
2.03
8.1
375
125
19.9
0.85
17
2.05
8.2
379
126
18.7
0.79
19
2.04
8.2
395
130
20.2
0.82
19
2.09
8.4
407
134
20.9
0.86
18
2.11
8.5
412
135
63
18.5
0.65
16
2.03
8.1
391
129
20.0
0.67
16
2.08
8.3
403
133
20.6
0.71
15
2.09
8.4
407
134
20.2
0.60
16
2.11
8.4
417
142
21.9
0.62
16
2.16
8.7
430
146
22.6
0.65
15
2.18
8.8
435
148
67
20.3
0.45
12
2.09
8.4
413
140
22.0
0.47
12
2.14
8.6
426
145
22.6
0.49
11
2.16
8.7
430
146
105ºF
16.8
0.89
20
2.07
8.4
406
126
18.2
0.93
19
2.12
8.7
418
130
18.8
0.97
19
2.13
8.8
423
132
59
16.5
0.79
17
2.05
8.4
402
125
17.9
0.81
17
2.10
8.6
414
129
18.4
0.85
16
2.12
8.7
418
130
17.3
0.80
18
2.11
8.7
437
134
18.8
0.83
18
2.16
8.9
450
139
19.3
0.87
17
2.18
9.0
455
140
63
17.1
0.66
15
2.09
8.6
432
133
18.6
0.68
15
2.14
8.8
446
137
19.1
0.71
14
2.16
8.9
450
139
18.7
0.60
15
2.18
8.9
461
147
20.3
0.63
15
2.23
9.2
475
151
20.9
0.66
14
2.25
9.3
480
153
67
18.8
0.45
11
2.16
8.9
456
145
20.3
0.47
11
2.21
9.1
471
150
21.0
0.49
11
2.23
9.2
475
151
20.1
0.39
10
2.25
9.3
481
156
21.8
0.40
10
2.30
9.6
496
161
22.4
0.42
10
2.32
9.7
501
163
-
71
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
21.7
0.39
11
2.17
8.8
435
151
23.5
0.40
11
2.23
9.0
449
156
24.2
0.42
10
2.25
9.1
453
157
-
71
115ºF
Expanded Cooling Data — ANX130241A* / CA*F3030*6D*+EEP
SS-ANX13
SS-ANX13
www.amana-hac.com
900
800
700
900
800
700
21.3
0.89
25
1.64
6.1
229
103
23.0
0.93
25
1.68
6.2
236
106
23.7
0.97
24
1.69
6.3
239
107
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
59
20.9
0.85
23
1.63
6.0
227
102
22.6
0.88
23
1.67
6.2
234
105
23.3
0.93
22
1.68
6.2
236
106
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
Amps
HI PR
LO PR
Airflow
63
21.7
0.86
25
1.67
6.2
247
110
23.5
0.90
24
1.71
6.4
254
113
24.2
0.94
23
1.72
6.4
257
114
21.4
0.80
22
1.66
6.2
244
109
23.1
0.83
22
1.70
6.3
252
112
23.8
0.87
21
1.71
6.4
254
113
67
22.7
0.78
23
1.72
6.4
260
120
24.6
0.81
23
1.76
6.6
268
123
25.3
0.85
22
1.78
6.7
271
125
22.8
0.65
20
1.71
6.4
258
119
24.7
0.68
19
1.75
6.5
266
122
25.5
0.71
18
1.76
6.6
268
123
24.2
0.63
20
1.77
6.7
272
128
26.2
0.66
20
1.82
6.8
280
131
27.0
0.69
19
1.83
6.9
283
133
71
24.4
0.5
16
1.8
6.6
268.9
126.3
26.4
0.5
15
1.8
6.8
277.2
130.2
27.2
0.5
15
1.8
6.8
280.0
131.5
20.8
0.93
25
1.76
6.6
257
109
22.5
0.96
25
1.80
6.7
265
112
23.2
1.00
24
1.81
6.8
268
113
59
20.4
0.88
24
1.74
6.5
255
108
22.1
0.92
23
1.79
6.7
262
111
22.8
0.96
22
1.80
6.7
265
112
63
21.2
0.89
25
1.79
6.7
277
116
22.9
0.93
24
1.84
6.9
285
119
23.6
0.97
23
1.85
7.0
288
121
20.9
0.83
23
1.78
6.7
274
115
22.6
0.86
22
1.82
6.8
282
118
23.3
0.90
21
1.84
6.9
285
119
67
22.2
0.81
24
1.85
6.9
292
127
24.0
0.84
23
1.89
7.1
301
130
24.8
0.88
22
1.91
7.2
304
132
22.3
0.68
20
1.83
6.9
289
125
24.2
0.70
19
1.88
7.1
298
129
24.9
0.73
19
1.89
7.1
301
130
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
23.7
0.65
20
1.90
7.2
305
135
25.6
0.68
20
1.95
7.4
314
139
26.4
0.71
19
1.97
7.5
317
140
71
23.8
0.50
16
1.89
7.1
302
133
25.8
0.52
16
1.94
7.3
311
138
26.6
0.55
15
1.95
7.4
314
139
63
20.7
0.92
25
1.90
7.3
315
120
22.4
0.95
24
1.95
7.5
324
124
23.1
1.00
24
1.96
7.6
328
125
20.4
0.85
23
1.89
7.2
312
119
22.1
0.88
22
1.93
7.4
321
123
22.7
0.92
21
1.95
7.5
324
124
67
21.7
0.83
24
1.96
7.5
332
132
23.5
0.86
23
2.01
7.8
343
136
24.2
0.90
22
2.02
7.8
346
137
21.8
0.69
20
1.94
7.5
329
130
23.6
0.72
19
1.99
7.7
339
134
24.3
0.75
19
2.01
7.8
343
136
71
23.1
0.67
20
2.02
7.8
347
140
25.0
0.70
20
2.07
8.1
357
144
25.8
0.73
19
2.09
8.1
361
146
23.3
0.5
16
2.0
7.8
343.1
138.7
25.2
0.5
16
2.1
8.0
353.8
143.0
26.0
0.6
15
2.1
8.1
357.3
144.4
Shaded area reflects AHRI conditions
20.3
0.95
25
1.86
7.1
292
113
22.0
0.99
25
1.91
7.3
301
117
22.6
1.00
23
1.92
7.4
304
118
59
19.9
0.91
24
1.85
7.1
290
112
21.6
0.94
23
1.89
7.3
298
116
22.2
1.00
23
1.91
7.3
301
117
59
19.8
0.98
25
1.95
7.6
333
119
21.4
1.00
25
2.00
7.8
343
123
22.1
1.00
23
2.02
7.9
347
124
19.4
0.94
24
1.94
7.6
330
118
21.1
0.97
24
1.99
7.8
340
121
21.7
1.00
22
2.00
7.8
343
123
63
20.2
0.95
25
1.99
7.8
358
127
21.9
0.98
25
2.04
8.0
369
130
22.5
1.00
23
2.06
8.1
373
132
19.9
0.88
23
1.98
7.7
355
125
21.5
0.91
23
2.03
8.0
366
129
22.2
0.95
22
2.04
8.0
369
130
67
21.1
0.85
24
2.06
8.1
378
138
22.9
0.89
23
2.11
8.3
390
142
23.6
0.93
22
2.12
8.4
394
144
21.2
0.71
20
2.04
8.0
375
137
23.0
0.74
20
2.09
8.2
386
141
23.7
0.78
19
2.11
8.3
390
142
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
22.5
0.69
21
2.12
8.4
395
147
24.4
0.72
20
2.17
8.6
407
152
25.1
0.75
19
2.19
8.7
411
153
71
22.7
0.53
16
2.11
8.3
391
146
24.6
0.55
16
2.16
8.5
403
150
25.3
0.58
15
2.17
8.6
407
152
18.8
1.00
25
2.03
8.1
375
125
20.4
1.00
23
2.08
8.3
386
129
21.0
1.00
21
2.10
8.4
390
130
59
18.5
0.97
24
2.02
8.0
371
123
20.0
1.00
23
2.07
8.3
382
127
20.6
1.00
21
2.08
8.3
386
129
19.2
0.98
25
2.08
8.3
403
133
20.8
1.00
24
2.13
8.6
416
137
21.4
1.00
22
2.14
8.6
420
138
63
18.9
0.91
23
2.06
8.2
399
131
20.5
0.94
22
2.11
8.5
412
135
21.1
1.00
22
2.13
8.6
416
137
20.1
0.89
23
2.14
8.6
426
145
21.7
0.92
23
2.19
8.8
439
149
22.4
0.96
22
2.21
8.9
443
151
67
20.2
0.74
20
2.12
8.5
422
143
21.9
0.77
19
2.18
8.8
435
148
22.5
0.81
19
2.19
8.8
439
149
105ºF
17.4
1.00
23
2.10
8.6
414
129
18.9
1.00
22
2.15
8.9
427
133
19.4
1.00
20
2.17
8.9
431
134
59
17.1
0.98
22
2.08
8.5
410
128
18.5
1.00
21
2.13
8.8
423
132
19.1
1.00
20
2.15
8.9
427
133
17.7
0.99
23
2.14
8.8
445
137
19.2
1.00
22
2.20
9.1
459
141
19.8
1.00
20
2.22
9.2
464
143
63
17.5
0.92
21
2.13
8.7
441
136
18.9
0.95
21
2.18
9.0
455
140
19.5
1.00
20
2.20
9.1
459
141
18.6
0.89
22
2.21
9.1
470
150
20.1
0.93
21
2.27
9.4
485
154
20.7
0.97
21
2.29
9.5
490
156
67
18.7
0.75
18
2.19
9.0
466
148
20.2
0.78
18
2.25
9.3
480
153
20.8
0.81
17
2.27
9.4
485
154
19.8
0.73
19
2.28
9.5
491
159
21.5
0.75
19
2.34
9.7
506
164
22.1
0.79
18
2.36
9.8
511
166
71
20.0
0.56
15
2.27
9.4
486
158
21.6
0.58
14
2.32
9.7
501
163
22.3
0.61
14
2.34
9.7
506
164
kW = Total system power
Amps = outdoor unit amps (comp.+fan)
21.4
0.72
20
2.21
8.9
444
154
23.2
0.75
20
2.26
9.2
458
159
23.9
0.78
19
2.28
9.3
462
161
71
21.6
0.6
16
2.2
8.8
439.7
152.7
23.4
0.6
15
2.2
9.1
453.3
157.4
24.1
0.6
15
2.3
9.2
457.8
158.9
115ºF
Expanded Cooling Data — ANX130241A* / CA*F3030*6D*+EEP (cont.)
9
10
www.amana-hac.com
700
800
900
700
800
900
22.9
0.83
19
1.64
5.9
231
106
22.3
0.79
20
1.63
5.8
228
105
20.5
0.76
21
1.59
5.7
222
102
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
59
22.5
0.73
17
1.63
5.8
228
105
21.9
0.70
18
1.62
5.8
226
104
20.2
0.67
18
1.58
5.6
219
101
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
Airflow
63
23.6
0.74
18
1.67
6.0
248
113
22.9
0.71
19
1.66
6.0
246
112
21.1
0.68
19
1.62
5.8
238
108
23.4
0.61
15
1.66
6.0
246
112
22.7
0.58
15
1.65
5.9
243
111
20.9
0.56
15
1.61
5.7
236
107
67
25.5
0.56
15
1.72
6.2
262
123
24.8
0.54
15
1.71
6.2
260
122
22.9
0.52
16
1.67
6.0
252
118
25.6
0.42
11
1.71
6.2
259
122
24.8
0.40
12
1.70
6.1
257
121
22.9
0.39
12
1.66
5.9
249
117
27.4
0.36
10
1.77
6.4
273
131
26.6
0.34
11
1.76
6.4
271
130
24.6
0.33
11
1.72
6.2
263
126
-
71
22.4
0.86
20
1.76
6.3
259
112
21.7
0.82
20
1.75
6.3
256
111
20.1
0.79
21
1.71
6.1
249
108
59
22.0
0.76
17
1.75
6.3
256
111
21.4
0.72
18
1.73
6.2
254
110
19.7
0.70
18
1.69
6.1
246
106
63
23.0
0.77
18
1.79
6.5
279
119
22.4
0.73
19
1.78
6.4
276
118
20.7
0.71
19
1.74
6.3
267
114
22.8
0.63
15
1.78
6.4
276
118
22.2
0.60
15
1.77
6.4
273
117
20.4
0.58
16
1.73
6.2
265
113
67
24.9
0.58
15
1.85
6.7
294
130
24.2
0.56
15
1.84
6.7
291
129
22.4
0.54
16
1.79
6.5
282
125
25.0
0.44
11
1.83
6.7
291
129
24.3
0.42
12
1.82
6.6
288
127
22.4
0.40
12
1.78
6.4
280
124
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
26.8
0.37
10
1.91
7.0
307
139
26.0
0.36
11
1.89
6.9
304
137
24.0
0.34
11
1.85
6.7
295
133
-
71
24.4
0.60
15
1.96
7.3
334
135
23.6
0.57
15
1.95
7.2
331
134
21.8
0.55
16
1.90
7.0
321
130
22.5
0.79
18
1.90
7.1
317
124
21.8
0.75
19
1.89
7.0
314
123
20.2
0.73
19
1.84
6.8
304
119
67
24.4
0.45
11
1.95
7.2
331
134
23.7
0.43
12
1.93
7.2
328
132
21.9
0.41
12
1.89
7.0
318
129
63
22.3
0.65
15
1.89
7.0
314
123
21.6
0.62
15
1.87
6.9
310
121
20.0
0.60
16
1.83
6.7
301
118
26.1
0.38
10
2.02
7.6
349
144
25.4
0.37
11
2.01
7.5
345
143
23.4
0.35
11
1.96
7.3
335
138
-
71
59
21.3
0.91
20
1.96
7.4
335
122
20.7
0.87
21
1.94
7.3
332
121
19.1
0.84
21
1.90
7.1
322
117
21.0
0.80
17
1.94
7.3
332
121
20.4
0.76
18
1.93
7.2
329
120
18.8
0.74
18
1.88
7.0
319
116
Shaded area reflects ACCA (TVA) conditions
21.9
0.88
20
1.86
6.9
294
116
21.2
0.84
21
1.85
6.8
291
115
19.6
0.81
21
1.81
6.6
283
112
59
21.5
0.78
17
1.85
6.8
291
115
20.9
0.74
18
1.84
6.8
288
114
19.3
0.71
18
1.79
6.6
280
111
63
22.0
0.81
18
2.00
7.5
361
130
21.3
0.78
19
1.98
7.5
357
129
19.7
0.75
19
1.94
7.3
346
125
21.7
0.67
15
1.98
7.5
357
129
21.1
0.64
15
1.97
7.4
354
127
19.5
0.62
16
1.92
7.2
343
124
67
23.8
0.62
15
2.06
7.8
381
142
23.1
0.59
16
2.04
7.7
377
141
21.3
0.57
16
2.00
7.5
366
136
23.8
0.46
11
2.04
7.7
377
141
23.1
0.44
12
2.03
7.7
373
139
21.3
0.43
12
1.98
7.4
362
135
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
25.5
0.40
10
2.13
8.1
397
151
24.8
0.38
11
2.11
8.0
393
150
22.9
0.36
11
2.06
7.8
382
145
-
71
20.3
0.95
20
2.04
7.8
377
128
19.7
0.90
20
2.02
7.8
373
127
18.2
0.87
21
1.97
7.6
362
123
59
19.9
0.83
17
2.02
7.8
373
127
19.3
0.79
18
2.00
7.7
370
126
17.8
0.76
18
1.96
7.5
359
122
20.9
0.85
18
2.08
8.0
406
136
20.2
0.81
19
2.06
8.0
402
135
18.7
0.78
19
2.01
7.7
390
131
63
20.6
0.69
15
2.06
8.0
402
135
20.0
0.66
15
2.05
7.9
398
134
18.5
0.64
16
2.00
7.7
386
130
22.6
0.64
15
2.15
8.3
429
149
21.9
0.61
15
2.13
8.2
424
147
20.2
0.59
16
2.08
8.0
412
143
67
22.6
0.48
11
2.13
8.2
424
147
22.0
0.46
12
2.11
8.1
420
146
20.3
0.44
12
2.06
7.9
407
141
105ºF
18.8
0.95
18
2.10
8.3
417
133
18.2
0.91
19
2.09
8.2
413
131
16.8
0.88
19
2.04
8.0
400
127
59
18.4
0.84
16
2.09
8.2
413
131
17.9
0.80
16
2.07
8.2
408
130
16.5
0.77
17
2.02
7.9
396
126
19.3
0.85
17
2.15
8.5
448
141
18.8
0.81
18
2.13
8.4
444
140
17.3
0.78
18
2.08
8.2
431
135
63
19.1
0.70
14
2.13
8.4
444
140
18.6
0.67
14
2.11
8.4
440
138
17.1
0.64
14
2.06
8.1
426
134
20.9
0.65
14
2.22
8.8
474
154
20.3
0.62
14
2.20
8.7
469
152
18.7
0.59
15
2.15
8.5
455
148
67
21.0
0.49
10
2.20
8.7
469
152
20.3
0.46
11
2.18
8.6
464
151
18.8
0.45
11
2.13
8.4
450
146
22.4
0.42
10
2.29
9.1
494
164
21.8
0.40
10
2.27
9.1
489
162
20.1
0.38
10
2.22
8.8
474
157
-
71
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
24.2
0.41
10
2.21
8.6
447
158
23.5
0.39
11
2.20
8.5
443
157
21.7
0.38
11
2.14
8.3
429
152
-
71
115ºF
Expanded Cooling Data — ANX130241B* / CA*F3030*6D*
SS-ANX13
SS-ANX13
www.amana-hac.com
700
800
900
700
800
900
23.7
0.95
23
1.66
6.0
235
108
23.0
0.91
24
1.65
5.9
233
107
21.3
0.88
25
1.61
5.8
226
104
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
59
23.3
0.91
22
1.65
5.9
233
107
22.6
0.87
23
1.64
5.9
231
106
20.9
0.84
23
1.60
5.7
224
103
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
MBh
S/T
∆T
kW
Amps
Hi PR
Lo PR
Airflow
63
24.2
0.92
23
1.70
6.1
253
115
23.5
0.88
24
1.69
6.1
251
114
21.7
0.85
24
1.65
5.9
243
110
23.8
0.85
21
1.69
6.1
251
114
23.1
0.81
22
1.67
6.0
248
113
21.4
0.79
22
1.63
5.9
241
109
67
25.3
0.83
22
1.75
6.3
267
126
24.6
0.79
22
1.74
6.3
265
124
22.7
0.76
23
1.70
6.1
257
121
25.5
0.69
18
1.74
6.3
265
124
24.7
0.66
19
1.72
6.2
262
123
22.8
0.64
19
1.68
6.0
254
119
27.0
0.67
19
1.80
6.6
279
134
26.2
0.64
19
1.79
6.5
276
132
24.2
0.62
20
1.75
6.3
268
128
71
27.2
0.52
14
1.79
6.5
276
132
26.4
0.50
15
1.78
6.4
273
131
24.4
0.48
15
1.73
6.3
265
127
23.2
0.99
23
1.79
6.5
264
114
22.5
0.94
24
1.77
6.4
261
113
20.8
0.91
25
1.73
6.2
254
110
59
22.8
0.94
22
1.77
6.4
261
113
22.1
0.90
23
1.76
6.3
259
112
20.4
0.87
23
1.72
6.2
251
109
63
23.6
0.95
23
1.82
6.6
284
122
22.9
0.91
24
1.81
6.6
281
120
21.2
0.88
24
1.77
6.4
273
117
23.3
0.88
21
1.81
6.6
281
120
22.6
0.84
22
1.79
6.5
279
119
20.9
0.81
22
1.75
6.3
270
116
67
24.8
0.86
22
1.88
6.8
300
133
24.0
0.82
23
1.86
6.8
297
131
22.2
0.79
23
1.82
6.6
288
127
24.9
0.72
18
1.86
6.8
297
131
24.2
0.69
19
1.85
6.7
294
130
22.3
0.66
19
1.81
6.5
285
126
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
26.4
0.70
19
1.94
7.1
313
141
25.6
0.67
20
1.92
7.0
310
140
23.7
0.64
20
1.88
6.8
301
136
71
26.6
0.54
15
1.92
7.0
310
140
25.8
0.51
15
1.91
7.0
307
139
23.8
0.50
15
1.86
6.8
298
134
63
23.1
0.98
23
1.93
7.2
323
126
22.4
0.93
24
1.92
7.1
320
125
20.7
0.90
24
1.87
6.9
310
121
22.7
0.91
21
1.92
7.1
320
125
22.1
0.87
22
1.90
7.1
317
124
20.4
0.83
22
1.86
6.9
307
120
67
24.2
0.88
22
1.99
7.4
341
138
23.5
0.84
23
1.98
7.4
338
137
21.7
0.81
23
1.93
7.2
328
132
24.3
0.74
18
1.98
7.4
338
137
23.6
0.70
19
1.96
7.3
335
135
21.8
0.68
19
1.92
7.1
324
131
71
25.8
0.72
19
2.06
7.7
356
147
25.0
0.68
20
2.04
7.6
352
145
23.1
0.66
20
1.99
7.4
342
141
26.0
0.55
15
2.04
7.6
352
145
25.2
0.53
15
2.02
7.6
349
144
23.3
0.51
16
1.98
7.4
338
140
Shaded area reflects AHRI conditions
22.6
1.00
23
1.89
7.0
300
119
22.0
0.97
24
1.88
7.0
297
118
20.3
0.93
25
1.83
6.8
288
114
59
22.2
0.97
22
1.88
7.0
297
118
21.6
0.92
23
1.86
6.9
294
116
19.9
0.89
23
1.82
6.7
286
113
59
22.1
1.00
23
1.99
7.5
342
125
21.4
1.00
25
1.97
7.4
339
123
19.8
0.96
25
1.93
7.2
328
120
21.7
1.00
22
1.97
7.4
339
123
21.1
0.95
23
1.96
7.4
335
122
19.4
0.92
23
1.91
7.2
325
119
63
22.5
1.00
23
2.03
7.7
368
133
21.9
0.96
24
2.01
7.6
364
131
20.2
0.93
25
1.97
7.4
353
127
22.2
0.94
21
2.01
7.6
364
131
21.5
0.89
22
2.00
7.5
361
130
19.9
0.86
22
1.95
7.3
350
126
67
23.6
0.91
22
2.09
7.9
389
145
22.9
0.87
23
2.08
7.9
385
143
21.1
0.84
23
2.03
7.7
373
139
23.7
0.76
18
2.08
7.9
385
143
23.0
0.73
19
2.06
7.8
381
142
21.2
0.70
20
2.01
7.6
370
138
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
25.1
0.74
19
2.16
8.2
405
154
24.4
0.71
20
2.14
8.2
401
153
22.5
0.68
20
2.09
7.9
389
148
71
25.3
0.57
15
2.14
8.2
401
153
24.6
0.54
15
2.13
8.1
397
151
22.7
0.52
16
2.08
7.9
385
147
21.0
1.00
21
2.07
8.0
385
131
20.4
1.00
23
2.05
7.9
381
129
18.8
1.00
25
2.00
7.7
370
126
59
20.6
1.00
21
2.05
7.9
381
129
20.0
0.99
23
2.04
7.8
377
128
18.5
0.95
23
1.99
7.6
366
124
21.4
1.00
22
2.11
8.2
414
139
20.8
1.00
24
2.10
8.1
410
138
19.2
0.96
24
2.05
7.9
398
134
63
21.1
1.00
22
2.10
8.1
410
138
20.5
0.93
22
2.08
8.0
406
136
18.9
0.89
22
2.03
7.8
394
132
22.4
0.95
22
2.18
8.5
437
152
21.7
0.90
23
2.16
8.4
433
150
20.1
0.87
23
2.11
8.1
420
146
67
22.5
0.79
18
2.16
8.4
433
150
21.9
0.75
19
2.15
8.3
429
149
20.2
0.73
19
2.09
8.1
416
144
105ºF
19.4
1.00
20
2.14
8.5
425
135
18.9
1.00
22
2.12
8.4
421
134
17.4
1.00
23
2.07
8.2
408
130
59
19.1
1.00
20
2.12
8.4
421
134
18.5
1.00
21
2.10
8.3
417
133
17.1
0.96
22
2.05
8.1
404
129
19.8
1.00
20
2.18
8.7
457
144
19.2
1.00
22
2.17
8.6
453
142
17.7
0.97
23
2.11
8.4
439
138
63
19.5
1.00
20
2.17
8.6
453
142
18.9
0.93
20
2.15
8.5
448
141
17.5
0.90
21
2.10
8.3
435
137
20.7
0.95
20
2.25
9.0
483
157
20.1
0.91
21
2.24
8.9
478
155
18.6
0.88
21
2.18
8.6
464
151
67
20.8
0.80
17
2.24
8.9
478
155
20.2
0.76
18
2.22
8.8
474
154
18.7
0.73
18
2.16
8.6
459
149
22.1
0.77
17
2.33
9.3
504
167
21.5
0.74
18
2.31
9.2
499
166
19.8
0.71
19
2.25
9.0
484
161
71
22.3
0.60
14
2.31
9.2
499
166
21.6
0.57
14
2.29
9.1
494
164
20.0
0.55
14
2.23
8.9
479
159
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
23.9
0.77
19
2.25
8.8
456
162
23.2
0.73
20
2.23
8.7
452
160
21.4
0.71
20
2.18
8.5
438
155
71
24.1
0.59
15
2.23
8.7
452
160
23.4
0.56
15
2.21
8.6
447
158
21.6
0.54
15
2.16
8.4
434
154
115ºF
Expanded Cooling Data — ANX130241B* / CA*F3030*6D* (cont.)
11
12
www.amana-hac.com
25.4
0.82
22
1.62
6.7
211
104
27.5
0.85
20
1.66
6.9
217
107
27.8
0.86
20
1.67
6.9
218
107
MBh
S/T
∆T
875
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1050 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1125 kW
Amps
HI PR
LO PR
59
24.9
0.72
19
1.60
6.6
209
103
27.0
0.74
18
1.65
6.8
215
106
27.3
0.76
17
1.65
6.9
216
106
MBh
S/T
∆T
kW
875
Amps
HI PR
LO PR
MBh
S/T
∆T
1050 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1125 kW
Amps
HI PR
LO PR
Airflow
63
26.1
0.73
20
1.66
6.9
227
110
28.3
0.76
19
1.70
7.1
234
114
28.6
0.77
18
1.71
7.1
234
114
25.8
0.60
16
1.64
6.8
224
109
28.0
0.62
15
1.69
7.0
231
113
28.3
0.63
15
1.69
7.0
232
113
67
28.3
0.55
16
1.72
7.1
239
121
30.6
0.57
15
1.76
7.3
247
124
30.9
0.58
15
1.77
7.4
248
125
28.3
0.42
12
1.70
7.0
237
119
30.7
0.43
12
1.75
7.3
244
123
31.0
0.44
11
1.75
7.3
245
123
30.3
0.36
11
1.78
7.4
250
128
32.9
0.37
11
1.83
7.6
257
132
33.2
0.38
10
1.83
7.7
258
133
-
71
24.8
0.85
22
1.76
7.3
236
110
26.8
0.88
21
1.81
7.5
244
113
27.1
0.89
20
1.81
7.5
245
113
59
24.4
0.74
19
1.74
7.2
234
109
26.4
0.77
18
1.79
7.4
241
112
26.7
0.79
17
1.80
7.5
242
112
63
25.5
0.76
20
1.80
7.5
254
117
27.6
0.78
19
1.85
7.7
262
120
27.9
0.80
18
1.86
7.7
263
121
25.2
0.62
16
1.78
7.4
252
116
27.4
0.64
15
1.83
7.6
260
119
27.6
0.66
15
1.84
7.7
260
119
67
27.6
0.57
17
1.87
7.7
269
127
29.9
0.59
16
1.92
8.0
277
131
30.2
0.61
15
1.92
8.0
278
132
27.7
0.43
13
1.85
7.7
266
126
30.0
0.45
12
1.90
7.9
274
130
30.3
0.45
11
1.91
7.9
275
130
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
29.6
0.37
11
1.93
8.1
280
136
32.1
0.38
11
1.99
8.3
289
140
32.4
0.39
10
1.99
8.3
290
140
-
71
63
24.9
0.78
20
1.93
8.2
289
121
27.0
0.80
19
1.98
8.4
298
125
27.2
0.82
18
1.99
8.5
299
125
24.6
0.64
16
1.91
8.1
286
120
26.7
0.66
15
1.97
8.3
295
124
27.0
0.67
15
1.97
8.4
296
124
67
26.9
0.59
17
2.00
8.5
306
132
29.2
0.61
16
2.06
8.7
315
136
29.5
0.62
15
2.06
8.8
316
137
27.0
0.44
13
1.98
8.4
303
131
29.3
0.46
12
2.04
8.6
312
135
29.5
0.47
11
2.04
8.7
313
136
28.9
0.38
11
2.07
8.8
319
141
31.3
0.39
11
2.13
9.1
329
145
31.6
0.40
10
2.14
9.1
330
146
-
71
59
23.6
0.89
22
1.99
8.6
306
120
25.6
0.93
21
2.05
8.8
316
123
25.8
0.95
20
2.06
8.9
317
124
23.2
0.79
19
1.97
8.5
303
119
25.1
0.82
18
2.03
8.7
313
122
25.4
0.83
17
2.04
8.8
314
123
Shaded area reflects ACCA (TVA) conditions
24.2
0.87
22
1.88
8.0
269
114
26.2
0.90
21
1.94
8.2
277
118
26.5
0.92
20
1.94
8.2
278
118
59
23.8
0.76
19
1.87
7.9
266
113
25.8
0.79
18
1.92
8.1
274
116
26.0
0.81
17
1.92
8.2
275
117
63
24.3
0.80
20
2.04
8.8
330
127
26.3
0.83
19
2.10
9.1
340
131
26.6
0.85
18
2.11
9.1
341
132
24.0
0.66
17
2.02
8.7
326
126
26.1
0.68
16
2.08
9.0
336
130
26.3
0.70
15
2.09
9.0
337
130
67
26.3
0.61
17
2.12
9.1
348
139
28.5
0.63
16
2.18
9.4
359
143
28.8
0.64
15
2.18
9.4
360
144
26.3
0.46
13
2.10
9.0
345
138
28.5
0.47
12
2.16
9.3
355
142
28.8
0.48
11
2.16
9.3
356
142
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
28.2
0.39
12
2.19
9.5
363
148
30.6
0.40
11
2.26
9.8
374
153
30.9
0.41
10
2.26
9.8
375
153
-
71
22.4
0.93
22
2.09
9.2
345
125
24.3
0.96
20
2.15
9.4
355
129
24.5
0.98
20
2.15
9.5
356
130
59
22.0
0.82
19
2.07
9.1
341
124
23.9
0.85
18
2.13
9.3
352
128
24.1
0.86
17
2.13
9.4
353
128
23.1
0.83
20
2.14
9.4
371
134
25.0
0.86
19
2.20
9.7
382
138
25.3
0.88
18
2.21
9.7
383
138
63
22.8
0.68
16
2.12
9.3
367
132
24.7
0.71
15
2.18
9.6
378
136
25.0
0.72
15
2.18
9.6
380
137
25.0
0.63
16
2.22
9.7
392
146
27.1
0.65
15
2.28
10.0
404
150
27.3
0.66
15
2.29
10.1
405
151
67
25.0
0.47
12
2.20
9.6
388
144
27.1
0.49
12
2.26
9.9
400
149
27.4
0.50
11
2.26
10.0
401
149
105ºF
20.8
0.94
20
2.17
9.7
381
130
22.5
0.97
19
2.23
10.0
393
134
22.7
0.99
18
2.24
10.1
394
134
59
20.4
0.82
18
2.15
9.6
377
128
22.1
0.85
17
2.21
9.9
389
132
22.3
0.87
16
2.21
10.0
390
133
21.4
0.84
19
2.22
10.0
410
138
23.2
0.87
18
2.28
10.3
422
142
23.4
0.89
17
2.29
10.3
424
143
63
21.2
0.69
15
2.20
9.9
406
137
22.9
0.71
14
2.26
10.2
418
141
23.2
0.73
14
2.27
10.2
419
141
23.1
0.63
15
2.30
10.4
433
151
25.1
0.66
14
2.37
10.7
446
155
25.3
0.67
14
2.37
10.7
447
156
67
23.2
0.48
12
2.28
10.2
428
149
25.1
0.49
11
2.35
10.6
442
154
25.4
0.50
10
2.35
10.6
443
154
24.8
0.41
11
2.39
10.8
451
161
26.9
0.42
10
2.46
11.1
465
166
27.2
0.43
10
2.46
11.1
467
166
-
71
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
26.8
0.40
11
2.30
10.1
408
155
29.0
0.42
11
2.36
10.4
421
160
29.3
0.43
10
2.37
10.5
422
161
-
71
115ºF
Expanded Cooling Data — ANX130301B* / CA*F3030*6D*+EEP
SS-ANX13
SS-ANX13
www.amana-hac.com
26.3
0.94
26
1.65
6.8
215
106
28.5
0.97
24
1.69
7.0
222
109
28.7
0.99
23
1.70
7.1
222
110
MBh
S/T
∆T
875
kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1050 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1125 kW
Amps
HI PR
LO PR
59
25.8
0.89
24
1.63
6.8
213
105
28.0
0.93
23
1.68
7.0
219
108
28.2
0.95
22
1.68
7.0
220
108
MBh
S/T
∆T
kW
875
Amps
HI PR
LO PR
MBh
S/T
∆T
1050 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1125 kW
Amps
HI PR
LO PR
Airflow
63
26.8
0.90
25
1.69
7.0
231
113
29.0
0.94
24
1.73
7.2
239
116
29.3
0.96
23
1.74
7.2
239
117
26.4
0.84
23
1.67
6.9
229
112
28.6
0.87
22
1.72
7.2
236
115
28.9
0.89
21
1.72
7.2
237
115
67
28.0
0.82
24
1.75
7.3
244
123
30.4
0.85
23
1.80
7.5
252
127
30.7
0.86
22
1.80
7.5
253
127
28.2
0.68
20
1.73
7.2
242
122
30.5
0.71
19
1.78
7.4
249
126
30.8
0.72
18
1.78
7.4
250
126
29.9
0.66
21
1.81
7.6
255
131
32.4
0.69
19
1.86
7.8
263
135
32.7
0.70
19
1.87
7.8
263
135
71
30.1
0.5
16
1.8
7.5
252.3
129.7
32.6
0.5
15
1.8
7.7
260.1
133.7
33.0
0.5
15
1.8
7.7
260.9
134.1
25.7
0.97
26
1.79
7.4
241
112
27.8
1.00
24
1.84
7.7
249
115
28.1
1.00
23
1.85
7.7
249
116
59
25.2
0.93
25
1.77
7.4
239
111
27.3
0.96
23
1.82
7.6
246
114
27.6
0.98
22
1.83
7.6
247
115
63
26.1
0.94
26
1.83
7.6
260
119
28.3
0.97
24
1.89
7.9
268
123
28.6
0.99
23
1.89
7.9
268
123
25.8
0.87
24
1.82
7.6
257
118
27.9
0.90
22
1.87
7.8
265
122
28.2
0.92
21
1.87
7.8
266
122
67
27.4
0.85
24
1.90
7.9
274
130
29.7
0.88
23
1.95
8.1
283
134
30.0
0.90
22
1.96
8.2
283
134
27.5
0.71
20
1.88
7.8
271
129
29.8
0.73
19
1.94
8.1
280
133
30.1
0.75
18
1.94
8.1
281
133
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
29.2
0.69
21
1.97
8.2
286
138
31.7
0.71
20
2.03
8.5
295
143
32.0
0.73
19
2.03
8.5
296
143
71
29.4
0.53
16
1.95
8.1
283
137
31.9
0.55
15
2.01
8.4
292
141
32.2
0.56
15
2.01
8.4
293
142
63
25.5
0.96
26
1.96
8.3
295
124
27.7
1.00
24
2.02
8.6
304
128
27.9
1.00
23
2.03
8.6
305
128
25.1
0.89
24
1.95
8.3
292
123
27.2
0.92
22
2.00
8.5
301
126
27.5
0.94
21
2.01
8.5
302
127
67
26.7
0.87
24
2.04
8.6
312
135
29.0
0.90
23
2.09
8.9
321
139
29.3
0.92
22
2.10
8.9
322
140
26.9
0.73
20
2.02
8.6
309
134
29.1
0.75
19
2.07
8.8
318
138
29.4
0.77
18
2.08
8.8
319
138
71
28.5
0.70
21
2.11
9.0
325
144
30.9
0.73
20
2.17
9.3
335
148
31.2
0.74
19
2.18
9.3
336
149
28.7
0.5
16
2.1
8.9
322.0
142.4
31.1
0.6
15
2.2
9.2
331.9
146.8
31.4
0.6
15
2.2
9.2
332.9
147.3
Shaded area reflects AHRI conditions
25.0
1.00
26
1.92
8.1
274
116
27.1
1.00
24
1.97
8.4
283
120
27.4
1.00
22
1.98
8.4
284
120
59
24.6
0.95
25
1.90
8.1
272
115
26.7
0.99
23
1.95
8.3
280
119
26.9
1.00
22
1.96
8.3
281
119
59
24.4
1.00
26
2.03
8.7
312
122
26.5
1.00
23
2.09
9.0
322
126
26.7
1.00
22
2.09
9.0
323
126
24.0
0.98
25
2.01
8.7
309
121
26.0
1.00
23
2.07
8.9
319
125
26.3
1.00
21
2.07
8.9
320
125
63
24.9
0.99
26
2.08
9.0
336
130
27.0
1.00
24
2.14
9.2
347
134
27.3
1.00
22
2.15
9.3
348
134
24.5
0.92
24
2.06
8.9
333
129
26.6
0.95
22
2.12
9.1
343
133
26.8
0.97
21
2.13
9.2
344
133
67
26.1
0.90
25
2.16
9.3
355
142
28.3
0.93
23
2.22
9.6
366
146
28.5
0.95
22
2.22
9.6
367
147
26.2
0.75
21
2.14
9.2
352
140
28.4
0.78
19
2.20
9.5
362
145
28.7
0.79
19
2.20
9.5
364
145
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
27.8
0.73
21
2.24
9.7
370
151
30.1
0.75
20
2.30
10.0
382
156
30.4
0.77
19
2.31
10.0
383
156
71
28.0
0.56
16
2.21
9.6
367
150
30.4
0.58
15
2.28
9.9
378
154
30.7
0.59
15
2.28
9.9
379
155
23.2
1.00
24
2.13
9.3
352
128
25.1
1.00
22
2.19
9.6
362
132
25.4
1.00
21
2.19
9.7
364
132
59
22.8
1.02
24
2.11
9.2
348
127
24.7
1.00
22
2.17
9.5
359
131
25.0
1.00
20
2.17
9.6
360
131
23.7
1.00
25
2.18
9.6
378
136
25.6
1.00
22
2.24
9.9
390
140
25.9
1.00
21
2.25
9.9
391
141
63
23.3
0.96
23
2.16
9.5
375
135
25.3
0.99
22
2.22
9.8
386
139
25.5
1.00
21
2.23
9.8
387
139
24.8
0.93
24
2.26
9.9
399
149
26.8
0.96
23
2.32
10.2
412
153
27.1
0.98
22
2.33
10.3
413
154
67
24.9
0.78
20
2.24
9.8
396
147
27.0
0.81
19
2.30
10.1
408
152
27.2
0.82
18
2.31
10.2
409
152
105ºF
21.5
1.00
23
2.21
9.9
388
132
23.3
1.00
20
2.27
10.2
400
137
23.5
1.00
19
2.28
10.3
402
137
59
21.1
1.03
23
2.19
9.8
385
131
22.9
1.00
20
2.25
10.1
396
135
23.1
1.00
19
2.26
10.2
398
136
21.9
1.00
23
2.26
10.2
418
141
23.7
1.00
21
2.33
10.5
431
145
24.0
1.00
20
2.33
10.5
432
146
63
21.6
0.96
22
2.24
10.1
414
139
23.4
1.00
20
2.31
10.4
427
144
23.6
1.00
19
2.31
10.4
428
144
23.0
0.94
23
2.35
10.6
441
154
24.9
0.97
21
2.41
10.9
455
159
25.1
0.99
20
2.42
10.9
456
159
67
23.1
0.78
19
2.32
10.5
437
152
25.0
0.81
18
2.39
10.8
451
157
25.2
0.83
17
2.40
10.8
452
157
24.5
0.76
20
2.43
11.0
460
164
26.5
0.79
18
2.50
11.3
475
169
26.8
0.80
18
2.51
11.4
476
169
71
24.7
0.59
15
2.41
10.9
456
162
26.7
0.61
14
2.48
11.2
470
167
27.0
0.62
14
2.49
11.2
471
168
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
26.4
0.75
21
2.34
10.3
417
158
28.6
0.78
20
2.41
10.6
430
163
28.9
0.80
19
2.42
10.7
431
164
71
26.6
0.6
16
2.3
10.2
412.5
156.8
28.8
0.6
15
2.4
10.5
425.3
161.6
29.1
0.6
15
2.4
10.6
426.6
162.1
115ºF
Expanded Cooling Data — ANX130301B* / CA*F3030*6D*+EEP (cont.)
13
14
www.amana-hac.com
30.0
0.77
20
2.34
8.6
237
102
32.5
0.80
20
2.40
8.8
244
105
33.5
0.84
19
2.41
8.9
247
106
MBh
S/T
∆T
1050 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1200 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1350 kW
Amps
HI PR
LO PR
59
29.5
0.68
18
2.32
8.5
235
101
32.0
0.71
17
2.38
8.8
242
104
32.9
0.74
17
2.40
8.8
244
105
MBh
S/T
∆T
1050 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1200 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1350 kW
Amps
HI PR
LO PR
Airflow
63
30.9
0.69
19
2.39
8.8
255
108
33.5
0.72
18
2.45
9.1
263
112
34.5
0.75
18
2.46
9.2
266
113
30.6
0.57
15
2.37
8.7
252
107
33.1
0.59
15
2.43
9.0
260
111
34.1
0.62
14
2.45
9.1
263
112
67
33.4
0.52
15
2.46
9.1
269
118
36.2
0.54
15
2.52
9.4
278
122
37.3
0.57
14
2.54
9.5
280
123
33.5
0.39
12
2.44
9.0
267
117
36.3
0.41
11
2.50
9.3
275
121
37.4
0.43
11
2.52
9.4
278
122
35.9
0.34
11
2.54
9.5
281
126
38.9
0.35
10
2.60
9.7
290
130
40.0
0.37
10
2.62
9.8
292
131
-
71
29.3
0.80
21
2.51
9.3
266
108
31.8
0.83
20
2.58
9.6
274
111
32.7
0.87
19
2.60
9.7
277
112
59
28.8
0.70
18
2.49
9.2
263
107
31.2
0.73
17
2.56
9.5
271
110
32.2
0.77
17
2.58
9.6
274
111
63
30.2
0.72
19
2.57
9.6
286
114
32.7
0.74
19
2.63
9.8
295
118
33.7
0.78
18
2.65
9.9
298
119
29.9
0.59
15
2.55
9.5
283
113
32.4
0.61
15
2.61
9.7
292
117
33.3
0.64
15
2.63
9.8
295
118
67
32.7
0.54
16
2.65
9.9
302
125
35.4
0.56
15
2.71
10.2
312
129
36.4
0.59
15
2.73
10.3
315
130
32.7
0.41
12
2.63
9.8
299
124
35.5
0.42
11
2.69
10.1
308
128
36.5
0.44
11
2.71
10.2
311
129
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
35.1
0.35
11
2.73
10.3
315
133
38.0
0.36
11
2.80
10.6
325
137
39.1
0.38
10
2.82
10.7
328
139
-
71
63
29.5
0.73
19
2.72
10.4
325
119
31.9
0.76
19
2.79
10.7
336
123
32.9
0.80
18
2.81
10.8
339
124
29.2
0.60
15
2.70
10.3
322
118
31.6
0.63
15
2.77
10.6
332
121
32.5
0.66
15
2.79
10.7
335
123
67
31.9
0.56
16
2.81
10.8
344
130
34.5
0.58
15
2.88
11.1
354
134
35.6
0.60
15
2.90
11.2
358
135
31.9
0.42
12
2.79
10.7
340
129
34.6
0.43
11
2.86
11.0
351
133
35.7
0.45
11
2.88
11.1
354
134
34.2
0.36
11
2.90
11.2
358
138
37.1
0.37
11
2.97
11.5
370
143
38.2
0.39
10
3.00
11.6
373
144
-
71
59
27.9
0.85
21
2.80
10.9
344
117
30.2
0.88
20
2.87
11.2
355
121
31.1
0.92
20
2.90
11.3
359
122
27.4
0.75
18
2.78
10.8
341
116
29.7
0.77
18
2.85
11.1
352
120
30.6
0.81
17
2.87
11.2
355
121
Shaded area reflects ACCA (TVA) conditions
28.6
0.82
21
2.67
10.2
302
112
31.0
0.85
20
2.73
10.5
312
115
31.9
0.89
19
2.76
10.6
315
116
59
28.1
0.72
18
2.65
10.1
299
111
30.5
0.75
17
2.71
10.4
309
114
31.4
0.79
17
2.73
10.5
312
115
63
28.7
0.76
19
2.86
11.2
371
125
31.1
0.79
19
2.94
11.5
382
129
32.1
0.82
18
2.96
11.6
386
130
28.4
0.62
16
2.84
11.1
367
124
30.8
0.65
15
2.91
11.4
378
128
31.7
0.68
15
2.93
11.5
382
129
67
31.1
0.57
16
2.96
11.6
391
136
33.7
0.60
15
3.03
11.9
404
141
34.7
0.62
15
3.05
12.0
408
142
31.2
0.43
12
2.93
11.4
387
135
33.8
0.45
12
3.00
11.8
399
139
34.8
0.47
11
3.03
11.9
403
141
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
33.4
0.37
11
3.05
12.0
408
145
36.2
0.38
11
3.13
12.4
421
150
37.3
0.40
10
3.15
12.5
425
151
-
71
26.5
0.88
20
2.92
11.6
388
123
28.7
0.91
20
2.99
12.0
399
127
29.6
0.96
19
3.02
12.1
403
128
59
26.1
0.77
18
2.89
11.5
384
122
28.2
0.80
17
2.97
11.8
395
126
29.1
0.84
17
2.99
12.0
399
127
27.3
0.79
19
2.98
11.9
417
131
29.6
0.82
18
3.06
12.3
430
135
30.5
0.86
18
3.08
12.4
434
136
63
27.0
0.65
15
2.96
11.8
413
130
29.3
0.67
15
3.03
12.1
426
134
30.2
0.70
14
3.06
12.3
430
135
29.6
0.60
15
3.08
12.3
440
143
32.0
0.62
15
3.16
12.7
454
147
33.0
0.65
15
3.18
12.8
459
149
67
29.6
0.45
12
3.05
12.2
436
142
32.1
0.46
11
3.13
12.6
449
146
33.0
0.49
11
3.16
12.7
454
147
105ºF
24.6
0.89
19
3.02
12.3
428
127
26.6
0.92
19
3.09
12.7
441
131
27.4
0.96
18
3.12
12.8
446
133
59
24.2
0.78
17
2.99
12.2
424
126
26.2
0.81
16
3.07
12.6
437
130
27.0
0.85
16
3.09
12.7
441
131
25.3
0.79
18
3.08
12.6
461
135
27.4
0.82
17
3.16
13.0
475
140
28.2
0.86
17
3.19
13.2
480
141
63
25.0
0.65
14
3.06
12.5
456
134
27.1
0.68
14
3.14
12.9
470
138
27.9
0.71
13
3.16
13.0
475
140
27.4
0.60
14
3.18
13.1
487
148
29.7
0.62
14
3.27
13.5
502
152
30.5
0.65
14
3.29
13.6
507
154
67
27.4
0.45
11
3.16
13.0
482
146
29.7
0.47
11
3.24
13.3
497
151
30.6
0.49
10
3.26
13.5
501
152
29.4
0.39
10
3.29
13.6
507
158
31.8
0.40
10
3.37
14.0
523
162
32.8
0.42
9
3.40
14.1
528
164
-
71
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
31.7
0.38
11
3.18
12.8
459
152
34.4
0.40
10
3.26
13.2
473
157
35.4
0.42
10
3.29
13.3
478
159
-
71
115ºF
Expanded Cooling Data — ANX130361A* / CA*F3636*6D*+EEP
SS-ANX13
SS-ANX13
www.amana-hac.com
31.1
0.89
24
2.38
8.8
242
104
33.7
0.92
24
2.43
9.0
249
107
34.7
0.97
23
2.45
9.1
252
108
MBh
S/T
∆T
1050 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1200 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1350 kW
Amps
HI PR
LO PR
59
30.5
0.85
23
2.36
8.7
239
103
33.1
0.88
22
2.42
8.9
247
106
34.1
0.92
21
2.43
9.0
249
107
MBh
S/T
∆T
1050 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1200 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1350 kW
Amps
HI PR
LO PR
Airflow
63
31.7
0.86
24
2.43
9.0
260
111
34.3
0.89
23
2.48
9.2
268
114
35.3
0.93
22
2.50
9.3
271
115
31.2
0.79
22
2.41
8.9
258
109
33.8
0.82
21
2.46
9.2
266
113
34.8
0.86
20
2.48
9.2
268
114
67
33.2
0.77
22
2.50
9.3
275
121
35.9
0.80
22
2.56
9.6
283
124
37.0
0.84
21
2.58
9.7
286
126
33.3
0.65
19
2.48
9.2
272
120
36.1
0.67
19
2.54
9.5
280
123
37.2
0.70
18
2.56
9.6
283
124
35.4
0.63
19
2.58
9.6
287
129
38.3
0.65
19
2.64
9.9
295
133
39.5
0.68
18
2.66
10.0
298
134
71
35.6
0.5
15
2.6
9.6
283.7
127.3
38.6
0.5
15
2.6
9.8
292.5
131.2
39.8
0.5
14
2.6
9.9
295.4
132.5
30.3
0.92
24
2.55
9.5
271
110
32.9
0.95
24
2.62
9.8
280
113
33.9
1.00
23
2.64
9.9
282
114
59
29.8
0.88
23
2.53
9.4
269
109
32.3
0.91
23
2.60
9.7
277
112
33.3
0.96
22
2.62
9.8
280
113
63
30.9
0.89
24
2.61
9.7
292
117
33.5
0.92
24
2.67
10.0
301
120
34.5
0.97
23
2.69
10.1
304
122
30.5
0.82
22
2.59
9.7
289
116
33.0
0.85
22
2.65
9.9
298
119
34.0
0.90
21
2.67
10.0
301
120
67
32.4
0.80
23
2.69
10.1
308
128
35.1
0.83
22
2.76
10.4
318
131
36.2
0.87
21
2.78
10.5
321
133
32.6
0.67
19
2.67
10.0
305
126
35.3
0.70
19
2.73
10.3
315
130
36.3
0.73
18
2.76
10.4
318
131
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
34.6
0.65
20
2.77
10.5
322
136
37.5
0.67
19
2.84
10.8
331
140
38.6
0.71
19
2.87
10.9
335
141
71
34.8
0.50
15
2.75
10.4
318
134
37.7
0.52
15
2.82
10.7
328
139
38.8
0.54
14
2.84
10.8
331
140
63
30.2
0.91
24
2.77
10.6
332
121
32.7
0.94
24
2.84
10.9
342
125
33.7
0.99
23
2.86
11.0
346
126
29.8
0.84
22
2.75
10.5
329
120
32.2
0.88
22
2.81
10.8
339
124
33.2
0.92
21
2.84
10.9
342
125
67
31.6
0.82
23
2.86
11.0
351
133
34.3
0.85
22
2.93
11.3
361
137
35.3
0.89
21
2.95
11.4
365
138
31.8
0.69
19
2.83
10.9
347
131
34.4
0.71
19
2.90
11.2
358
135
35.5
0.75
18
2.93
11.3
361
137
71
33.7
0.67
20
2.95
11.4
366
141
36.6
0.69
19
3.02
11.8
377
146
37.7
0.73
19
3.05
11.9
381
147
34.0
0.5
15
2.9
11.3
362.1
139.8
36.8
0.5
15
3.0
11.6
373.3
144.1
37.9
0.6
14
3.0
11.8
377.0
145.5
Shaded area reflects AHRI conditions
29.6
0.94
24
2.71
10.4
309
114
32.1
0.98
24
2.78
10.7
318
118
33.1
1.00
23
2.80
10.8
321
119
59
29.1
0.90
23
2.69
10.3
305
113
31.5
0.93
23
2.76
10.6
315
116
32.5
1.00
22
2.78
10.7
318
118
28.9
0.97
25
2.85
11.1
351
120
31.3
1.00
24
2.92
11.4
362
124
32.3
1.00
22
2.94
11.5
366
125
28.4
0.93
23
2.83
11.0
348
119
30.8
0.96
23
2.90
11.3
359
122
31.7
1.00
22
2.92
11.4
362
124
59
29.5
0.94
24
2.91
11.4
378
128
31.9
0.98
24
2.98
11.7
390
131
32.9
1.00
22
3.01
11.8
394
133
29.0
0.87
22
2.89
11.3
374
126
31.4
0.90
22
2.96
11.6
386
130
32.4
0.95
21
2.98
11.7
390
131
63
30.9
0.85
23
3.00
11.8
399
139
33.4
0.88
23
3.08
12.1
412
144
34.4
0.92
22
3.10
12.2
416
145
31.0
0.71
19
2.98
11.7
395
138
33.6
0.74
19
3.05
12.0
408
142
34.6
0.77
18
3.08
12.1
412
144
67
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
32.9
0.69
20
3.10
12.2
416
148
35.7
0.71
20
3.18
12.6
429
153
36.7
0.75
19
3.21
12.7
434
154
71
33.2
0.53
15
3.08
12.1
412
147
35.9
0.55
15
3.15
12.5
425
151
37.0
0.58
15
3.18
12.6
429
153
27.5
1.00
24
2.97
11.8
395
126
29.7
1.00
23
3.04
12.2
408
130
30.6
1.00
21
3.07
12.3
412
131
59
27.0
0.96
23
2.94
11.7
391
124
29.2
1.00
22
3.02
12.1
404
128
30.1
1.00
21
3.04
12.2
408
130
28.0
0.98
24
3.03
12.1
425
134
30.3
1.00
23
3.11
12.5
439
138
31.2
1.00
21
3.13
12.6
443
139
63
27.6
0.90
22
3.01
12.0
421
132
29.9
0.94
21
3.08
12.4
434
136
30.8
1.00
21
3.11
12.5
439
138
29.3
0.88
23
3.13
12.6
449
146
31.8
0.91
22
3.21
12.9
463
150
32.7
0.96
21
3.24
13.1
468
152
67
29.5
0.74
19
3.10
12.4
445
144
31.9
0.76
19
3.18
12.8
459
149
32.9
0.80
18
3.21
12.9
463
150
105ºF
25.4
1.00
22
3.07
12.6
437
130
27.6
1.00
21
3.15
12.9
450
134
28.4
1.00
19
3.17
13.1
455
135
59
25.0
0.97
21
3.04
12.5
432
129
27.1
1.00
21
3.12
12.8
446
133
27.9
1.00
19
3.15
12.9
450
134
25.9
0.98
22
3.13
12.9
470
138
28.1
1.00
22
3.21
13.3
485
143
28.9
1.00
20
3.24
13.4
489
144
63
25.5
0.91
20
3.11
12.8
465
137
27.7
0.95
20
3.19
13.2
480
141
28.5
1.00
19
3.21
13.3
485
143
27.2
0.89
21
3.24
13.3
496
151
29.4
0.92
21
3.32
13.7
512
156
30.3
0.97
20
3.35
13.9
517
157
67
27.3
0.74
18
3.21
13.2
491
149
29.6
0.77
17
3.29
13.6
507
154
30.5
0.81
17
3.32
13.7
512
156
29.0
0.72
18
3.34
13.9
518
161
31.4
0.75
18
3.43
14.3
534
166
32.3
0.78
17
3.46
14.4
539
167
71
29.2
0.56
14
3.32
13.7
513
159
31.6
0.58
14
3.40
14.1
528
164
32.6
0.60
13
3.43
14.3
534
166
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
31.3
0.71
20
3.23
13.1
469
155
33.9
0.74
19
3.32
13.4
483
160
34.9
0.78
18
3.34
13.6
488
162
71
31.5
0.6
15
3.2
12.9
463.9
153.8
34.1
0.6
15
3.3
13.3
478.3
158.6
35.1
0.6
14
3.3
13.4
483.1
160.2
115ºF
Expanded Cooling Data — ANX130361A* / CA*F3636*6D*+EEP (cont.)
15
16
www.amana-hac.com
35.7
0.82
22
2.83
10.4
222
102
38.7
0.85
22
2.89
10.7
229
105
39.9
0.90
21
2.91
10.8
231
106
MBh
S/T
∆T
1225 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1400 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1575 kW
Amps
HI PR
LO PR
59
35.1
0.72
19
2.81
10.3
220
101
38.1
0.75
19
2.87
10.6
227
104
39.2
0.79
18
2.89
10.7
229
105
MBh
S/T
∆T
1225 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1400 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1575 kW
Amps
HI PR
LO PR
Airflow
63
36.8
0.74
20
2.88
10.7
239
108
39.8
0.76
20
2.95
11.0
247
112
41.0
0.80
19
2.97
11.1
249
113
36.4
0.60
17
2.86
10.6
237
107
39.4
0.63
16
2.92
10.9
244
111
40.6
0.66
16
2.94
11.0
247
112
67
39.8
0.56
17
2.96
11.0
253
118
43.1
0.58
16
3.03
11.3
260
122
44.4
0.61
16
3.05
11.4
263
123
39.9
0.42
13
2.94
10.9
250
117
43.2
0.43
12
3.01
11.2
258
121
44.5
0.46
12
3.03
11.3
260
122
42.7
0.36
11
3.05
11.4
263
126
46.3
0.37
11
3.12
11.7
272
130
47.7
0.39
11
3.14
11.8
274
131
-
71
34.9
0.85
22
3.02
11.2
249
108
37.8
0.88
22
3.09
11.6
257
111
38.9
0.93
21
3.12
11.7
260
112
59
34.3
0.75
19
3.00
11.1
247
107
37.2
0.78
19
3.07
11.5
255
110
38.3
0.82
18
3.09
11.6
257
111
63
35.9
0.76
21
3.08
11.5
268
115
38.9
0.79
20
3.15
11.8
277
118
40.1
0.83
19
3.18
11.9
279
119
35.6
0.63
17
3.06
11.4
266
113
38.5
0.65
16
3.13
11.7
274
117
39.7
0.68
16
3.15
11.8
277
118
67
38.9
0.58
17
3.17
11.9
283
125
42.1
0.60
17
3.25
12.2
292
129
43.4
0.63
16
3.27
12.3
295
130
39.0
0.43
13
3.15
11.8
281
124
42.2
0.45
12
3.22
12.1
289
128
43.5
0.47
12
3.25
12.2
292
129
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
41.7
0.37
12
3.27
12.3
296
133
45.2
0.39
11
3.35
12.7
305
137
46.6
0.40
11
3.37
12.8
308
139
-
71
63
35.1
0.78
21
3.26
12.5
305
119
38.0
0.81
20
3.34
12.8
315
123
39.1
0.85
19
3.36
13.0
318
124
34.7
0.64
17
3.24
12.4
302
118
37.6
0.67
16
3.31
12.7
312
122
38.7
0.70
16
3.34
12.8
315
123
67
38.0
0.59
17
3.36
12.9
322
130
41.1
0.61
17
3.44
13.3
332
134
42.4
0.64
16
3.47
13.4
336
135
38.0
0.45
13
3.33
12.8
319
129
41.2
0.46
12
3.41
13.1
329
133
42.4
0.48
12
3.44
13.3
332
134
40.7
0.38
12
3.46
13.4
336
138
44.1
0.40
11
3.54
13.8
347
143
45.5
0.41
11
3.57
13.9
350
144
-
71
59
33.2
0.90
23
3.35
13.0
323
118
36.0
0.94
22
3.43
13.4
333
121
37.1
0.98
21
3.46
13.5
336
122
32.7
0.79
19
3.33
12.9
320
116
35.4
0.82
19
3.40
13.3
330
120
36.5
0.86
18
3.43
13.4
333
121
Shaded area reflects ACCA (TVA) conditions
34.1
0.87
22
3.20
12.2
284
112
36.9
0.91
22
3.27
12.5
292
115
38.0
0.95
21
3.30
12.7
295
117
59
33.5
0.77
19
3.17
12.1
281
111
36.3
0.80
19
3.25
12.4
289
114
37.4
0.84
18
3.27
12.5
292
115
63
34.2
0.81
21
3.42
13.3
348
125
37.1
0.84
20
3.50
13.7
358
129
38.2
0.88
20
3.53
13.8
362
130
33.9
0.66
17
3.39
13.2
344
124
36.7
0.69
17
3.47
13.6
355
128
37.8
0.72
16
3.50
13.7
358
129
67
37.0
0.61
17
3.52
13.8
367
137
40.1
0.63
17
3.61
14.2
378
141
41.3
0.66
16
3.64
14.3
382
142
37.1
0.46
13
3.50
13.7
363
135
40.2
0.48
13
3.58
14.0
375
139
41.4
0.50
12
3.61
14.2
378
141
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
39.7
0.39
12
3.63
14.3
383
145
43.1
0.41
12
3.72
14.7
395
150
44.4
0.43
11
3.75
14.8
399
151
-
71
31.6
0.94
22
3.48
13.9
363
123
34.2
0.97
22
3.57
14.3
375
127
35.2
1.00
21
3.59
14.4
378
128
59
31.0
0.82
19
3.45
13.7
360
122
33.6
0.86
19
3.54
14.1
371
126
34.6
0.90
18
3.56
14.2
375
127
32.5
0.84
20
3.55
14.2
391
131
35.2
0.87
20
3.64
14.6
403
135
36.3
0.91
19
3.67
14.7
407
136
63
32.2
0.69
17
3.53
14.1
387
130
34.9
0.71
16
3.61
14.5
399
134
35.9
0.75
16
3.64
14.6
403
135
35.2
0.63
17
3.66
14.7
413
143
38.1
0.66
16
3.75
15.1
426
148
39.3
0.69
16
3.78
15.2
430
149
67
35.2
0.48
13
3.63
14.5
409
142
38.2
0.49
12
3.72
14.9
421
146
39.3
0.52
12
3.75
15.1
426
148
105ºF
29.2
0.95
21
3.59
14.7
402
127
31.7
0.98
20
3.68
15.1
414
131
32.6
1.00
19
3.71
15.2
418
133
59
28.8
0.83
18
3.57
14.5
398
126
31.2
0.86
18
3.65
15.0
410
130
32.1
0.90
17
3.68
15.1
414
131
30.1
0.85
19
3.67
15.0
432
136
32.6
0.88
19
3.76
15.5
446
140
33.6
0.92
18
3.79
15.6
450
141
63
29.8
0.69
16
3.64
14.9
428
134
32.3
0.72
15
3.73
15.3
441
138
33.3
0.76
15
3.76
15.5
445
140
32.6
0.64
16
3.78
15.5
456
148
35.3
0.66
15
3.88
16.0
470
153
36.4
0.70
15
3.91
16.1
475
154
67
32.7
0.48
12
3.75
15.4
452
147
35.4
0.50
12
3.84
15.8
466
151
36.4
0.52
11
3.87
16.0
470
153
35.0
0.41
11
3.90
16.1
476
158
37.9
0.43
11
4.00
16.6
491
163
39.0
0.45
10
4.03
16.7
496
164
-
71
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
37.8
0.41
12
3.78
15.2
431
152
40.9
0.42
11
3.87
15.7
444
157
42.1
0.44
11
3.90
15.8
449
159
-
71
115ºF
Expanded Cooling Data — ANX130421A* / CA*F3642*6D*+EEP
SS-ANX13
SS-ANX13
www.amana-hac.com
37.0
0.95
26
2.87
10.6
227
104
40.1
0.98
26
2.93
10.9
234
107
41.3
1.00
24
2.95
11.0
236
108
MBh
S/T
∆T
1225 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1400 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1575 kW
Amps
HI PR
LO PR
59
36.4
0.90
25
2.85
10.5
225
103
39.4
0.94
24
2.91
10.8
231
106
40.6
1.00
24
2.93
10.9
234
107
MBh
S/T
∆T
1225 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1400 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1575 kW
Amps
HI PR
LO PR
Airflow
63
37.7
0.91
26
2.92
10.9
244
111
40.9
0.95
25
2.99
11.2
252
114
42.1
0.99
24
3.01
11.3
254
115
37.1
0.85
24
2.90
10.8
242
110
40.2
0.88
23
2.97
11.1
249
113
41.5
0.92
22
2.99
11.2
252
114
67
39.5
0.82
24
3.01
11.2
258
121
42.8
0.85
24
3.08
11.5
266
125
44.1
0.90
23
3.10
11.6
268
126
39.7
0.69
21
2.98
11.1
255
120
43.0
0.71
20
3.05
11.4
263
123
44.3
0.75
19
3.08
11.5
266
125
42.1
0.67
21
3.10
11.6
269
129
45.6
0.69
21
3.17
11.9
277
133
47.0
0.73
20
3.19
12.0
280
134
71
42.4
0.5
16
3.1
11.5
266.1
127.4
46.0
0.5
16
3.1
11.8
274.3
131.3
47.3
0.6
15
3.2
11.9
277.1
132.6
36.1
0.98
27
3.07
11.5
254
110
39.1
1.00
26
3.14
11.8
262
113
40.3
1.00
24
3.16
11.9
265
114
59
35.5
0.94
25
3.05
11.4
252
109
38.5
0.97
25
3.12
11.7
260
112
39.6
1.00
23
3.14
11.8
262
113
63
36.8
0.95
26
3.13
11.7
274
117
39.9
0.98
26
3.20
12.0
282
121
41.1
1.00
24
3.23
12.2
285
122
36.3
0.88
24
3.11
11.6
271
116
39.3
0.91
23
3.18
11.9
279
119
40.5
0.95
23
3.20
12.0
282
121
67
38.6
0.85
25
3.22
12.1
289
128
41.8
0.89
24
3.30
12.4
298
132
43.0
0.93
23
3.32
12.6
301
133
38.8
0.71
21
3.20
12.0
286
126
42.0
0.74
20
3.27
12.3
295
130
43.3
0.78
20
3.30
12.4
298
132
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
41.2
0.69
21
3.32
12.6
302
136
44.6
0.72
21
3.40
12.9
311
140
45.9
0.75
20
3.42
13.0
314
142
71
41.4
0.53
17
3.29
12.4
299
135
44.9
0.55
16
3.37
12.8
308
139
46.2
0.58
16
3.40
12.9
311
140
63
36.0
0.97
26
3.31
12.7
311
121
39.0
1.00
26
3.39
13.1
321
125
40.1
1.00
23
3.42
13.2
324
126
35.4
0.90
24
3.29
12.6
308
120
38.4
0.93
24
3.36
13.0
318
124
39.5
1.00
23
3.39
13.1
321
125
67
37.7
0.88
25
3.41
13.1
329
133
40.8
0.91
24
3.49
13.5
339
137
42.0
0.95
23
3.52
13.6
342
138
37.8
0.73
21
3.39
13.0
326
131
41.0
0.76
20
3.47
13.4
336
135
42.2
0.80
20
3.49
13.5
339
137
71
40.2
0.71
21
3.52
13.6
343
141
43.5
0.74
21
3.60
14.0
354
146
44.8
0.77
20
3.63
14.1
357
147
40.5
0.5
17
3.5
13.5
339.6
139.8
43.8
0.6
16
3.6
13.9
350.1
144.2
45.1
0.6
16
3.6
14.0
353.6
145.6
Shaded area reflects AHRI conditions
35.3
1.00
26
3.25
12.4
289
114
38.2
1.00
25
3.32
12.8
298
118
39.4
1.00
23
3.35
12.9
301
119
59
34.7
0.96
25
3.22
12.3
287
113
37.6
1.00
25
3.30
12.7
295
117
38.7
1.00
23
3.32
12.8
298
118
59
34.4
1.00
26
3.40
13.3
330
120
37.3
1.00
24
3.48
13.6
340
124
38.4
1.00
22
3.51
13.8
343
125
33.8
0.99
25
3.38
13.2
326
119
36.6
1.00
24
3.46
13.5
336
122
37.7
1.00
22
3.48
13.6
340
124
63
35.1
1.00
26
3.47
13.6
355
128
38.0
1.00
25
3.56
14.0
366
132
39.1
1.00
23
3.58
14.1
369
133
34.6
0.93
24
3.45
13.5
351
126
37.4
0.96
24
3.53
13.9
362
130
38.6
1.00
23
3.56
14.0
366
132
67
36.7
0.90
25
3.58
14.0
375
139
39.8
0.94
25
3.66
14.4
386
144
41.0
0.98
24
3.69
14.6
390
145
36.9
0.76
21
3.55
13.9
371
138
40.0
0.78
21
3.64
14.3
382
142
41.2
0.82
20
3.66
14.4
386
144
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
39.2
0.73
22
3.69
14.6
391
148
42.5
0.76
21
3.78
15.0
403
153
43.7
0.80
20
3.81
15.1
407
154
71
39.5
0.57
17
3.66
14.4
387
147
42.8
0.59
16
3.75
14.8
399
151
44.0
0.61
16
3.78
15.0
403
153
32.7
1.00
25
3.54
14.1
371
126
35.4
1.00
23
3.62
14.5
382
130
36.5
1.00
21
3.65
14.6
386
131
59
32.1
1.03
25
3.51
14.0
367
124
34.8
1.00
23
3.59
14.4
378
128
35.9
1.00
21
3.62
14.5
382
130
33.3
1.00
25
3.61
14.5
399
134
36.1
1.00
24
3.70
14.9
411
138
37.2
1.00
22
3.73
15.0
415
139
63
32.8
0.96
24
3.58
14.3
395
132
35.6
1.00
23
3.67
14.7
407
137
36.6
1.00
21
3.70
14.9
411
138
34.9
0.94
25
3.72
14.9
421
146
37.8
0.97
24
3.81
15.4
434
151
38.9
1.00
23
3.84
15.5
439
152
67
35.1
0.78
21
3.69
14.8
417
145
38.0
0.81
20
3.78
15.2
430
149
39.1
0.85
19
3.81
15.4
434
151
105ºF
30.3
1.00
23
3.65
14.9
410
130
32.8
1.00
22
3.74
15.4
422
134
33.8
1.00
20
3.77
15.5
427
135
59
29.8
1.04
23
3.62
14.8
406
129
32.2
1.00
21
3.71
15.2
418
133
33.2
1.00
19
3.74
15.4
422
134
30.9
1.00
23
3.73
15.3
441
138
33.4
1.00
22
3.82
15.7
455
143
34.4
1.00
20
3.85
15.9
459
144
63
30.4
0.97
22
3.70
15.2
437
137
32.9
1.00
22
3.79
15.6
450
141
33.9
1.00
20
3.82
15.7
455
143
32.3
0.95
23
3.84
15.8
466
151
35.0
0.98
23
3.94
16.3
480
156
36.1
1.00
21
3.97
16.4
485
157
67
32.5
0.79
19
3.81
15.7
461
150
35.2
0.82
19
3.91
16.1
475
154
36.3
0.86
18
3.94
16.3
480
156
34.5
0.77
20
3.97
16.4
486
161
37.4
0.80
20
4.06
16.9
501
166
38.5
0.83
19
4.10
17.1
506
167
71
34.7
0.59
15
3.93
16.3
481
159
37.6
0.61
15
4.03
16.7
496
164
38.8
0.64
15
4.06
16.9
501
166
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
37.2
0.76
21
3.84
15.5
439
155
40.3
0.79
21
3.93
15.9
453
160
41.5
0.83
20
3.96
16.1
458
162
71
37.5
0.6
17
3.8
15.4
435.1
154.0
40.6
0.6
16
3.9
15.8
448.6
158.7
41.8
0.6
16
3.9
15.9
453.1
160.3
115ºF
Cooling Data — ANX130421A* / CA*F3642*6D*+EEP (cont.)
17
18
www.amana-hac.com
41.1
0.80
22
3.24
11.9
243
105
44.5
0.83
21
3.31
12.3
251
108
45.8
0.87
20
3.34
12.4
253
109
MBh
S/T
∆T
1400 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1600 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1800 kW
Amps
HI PR
LO PR
59
40.4
0.71
19
3.22
11.8
241
104
43.8
0.73
18
3.29
12.2
248
107
45.1
0.77
18
3.31
12.3
251
108
MBh
S/T
∆T
1400 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1600 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1800 kW
Amps
HI PR
LO PR
Airflow
63
42.3
0.72
20
3.30
12.2
262
111
45.8
0.75
20
3.38
12.6
270
115
47.2
0.78
19
3.40
12.7
273
116
41.9
0.59
16
3.28
12.1
259
110
45.4
0.61
16
3.35
12.5
267
114
46.7
0.64
15
3.38
12.6
270
115
67
45.8
0.54
16
3.40
12.6
276
122
49.6
0.56
16
3.48
13.0
285
125
51.1
0.59
15
3.50
13.1
288
127
45.9
0.41
12
3.37
12.5
274
120
49.7
0.42
12
3.45
12.9
282
124
51.2
0.44
12
3.48
13.0
285
125
49.1
0.35
11
3.50
13.1
288
130
53.2
0.36
11
3.58
13.5
297
134
54.8
0.38
11
3.61
13.6
300
135
-
71
40.1
0.83
22
3.47
12.9
273
111
43.5
0.86
22
3.55
13.3
281
114
44.8
0.91
21
3.58
13.4
284
115
59
39.5
0.73
19
3.44
12.8
270
110
42.7
0.76
19
3.52
13.1
279
113
44.0
0.80
18
3.55
13.3
281
114
63
41.3
0.74
20
3.54
13.2
294
118
44.8
0.77
20
3.62
13.6
303
121
46.1
0.81
19
3.65
13.7
306
123
40.9
0.61
16
3.51
13.1
291
117
44.3
0.63
16
3.59
13.5
300
120
45.6
0.67
16
3.62
13.6
303
121
67
44.7
0.56
17
3.64
13.7
310
129
48.4
0.58
16
3.73
14.0
320
132
49.9
0.61
16
3.76
14.2
323
134
44.8
0.42
12
3.62
13.5
307
127
48.5
0.44
12
3.70
13.9
317
131
50.0
0.46
12
3.73
14.0
320
132
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
48.0
0.36
11
3.75
14.2
324
137
52.0
0.38
11
3.84
14.6
334
141
53.6
0.39
11
3.87
14.7
337
143
-
71
63
40.3
0.76
20
3.75
14.4
334
122
43.7
0.79
20
3.83
14.8
344
126
45.0
0.83
19
3.86
14.9
348
127
39.9
0.63
16
3.72
14.2
331
121
43.2
0.65
16
3.80
14.6
341
125
44.5
0.68
16
3.83
14.8
344
126
67
43.7
0.58
17
3.86
14.8
353
134
47.3
0.60
16
3.95
15.3
364
138
48.7
0.63
16
3.98
15.4
367
139
43.7
0.43
12
3.83
14.7
349
132
47.4
0.45
12
3.92
15.1
360
136
48.8
0.47
12
3.95
15.3
364
138
46.8
0.37
11
3.98
15.4
368
142
50.8
0.39
11
4.08
15.8
379
147
52.3
0.40
11
4.11
16.0
383
148
-
71
59
38.2
0.88
22
3.85
15.0
354
121
41.4
0.91
22
3.94
15.4
365
125
42.6
0.96
21
3.97
15.6
368
126
37.6
0.78
19
3.82
14.8
350
120
40.7
0.80
19
3.91
15.3
361
123
41.9
0.84
18
3.94
15.4
365
125
Shaded area reflects ACCA (TVA) conditions
39.2
0.85
22
3.67
14.0
311
115
42.4
0.89
22
3.76
14.4
320
119
43.7
0.93
21
3.79
14.5
323
120
59
38.5
0.75
19
3.64
13.9
307
114
41.7
0.78
19
3.73
14.3
317
117
43.0
0.82
18
3.76
14.4
320
119
63
39.3
0.79
20
3.93
15.4
381
129
42.6
0.82
20
4.02
15.8
392
132
43.9
0.86
19
4.06
15.9
396
134
38.9
0.65
17
3.90
15.2
377
127
42.2
0.67
16
3.99
15.6
388
131
43.5
0.70
16
4.02
15.8
392
132
67
42.6
0.60
17
4.05
15.9
402
140
46.1
0.62
16
4.15
16.3
414
145
47.5
0.65
16
4.18
16.5
418
146
42.7
0.45
13
4.02
15.7
398
139
46.2
0.47
12
4.12
16.2
410
143
47.6
0.49
12
4.15
16.3
414
145
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
45.7
0.38
12
4.18
16.5
419
149
49.5
0.40
11
4.28
16.9
432
154
51.0
0.42
11
4.31
17.1
436
156
-
71
36.3
0.91
22
4.00
15.9
398
127
39.3
0.95
21
4.10
16.4
410
131
40.5
0.99
21
4.13
16.6
414
132
59
35.7
0.80
19
3.97
15.8
394
125
38.7
0.83
19
4.07
16.2
406
129
39.8
0.87
18
4.10
16.4
410
130
37.4
0.82
20
4.09
16.3
428
135
40.5
0.85
20
4.18
16.8
441
139
41.7
0.89
19
4.22
17.0
446
140
63
37.0
0.67
16
4.05
16.2
424
133
40.1
0.70
16
4.15
16.6
437
137
41.3
0.73
15
4.18
16.8
441
139
40.5
0.62
16
4.21
16.9
452
147
43.8
0.64
16
4.32
17.4
466
152
45.1
0.67
16
4.35
17.5
471
153
67
40.5
0.47
12
4.18
16.7
448
146
43.9
0.48
12
4.28
17.2
461
150
45.2
0.51
12
4.32
17.4
466
152
105ºF
33.6
0.92
20
4.13
16.9
440
131
36.4
0.96
20
4.23
17.4
453
135
37.5
1.00
19
4.27
17.5
458
136
59
33.1
0.81
18
4.10
16.7
435
130
35.8
0.84
17
4.20
17.2
449
134
36.9
0.88
17
4.23
17.4
453
135
34.6
0.82
19
4.22
17.3
473
139
37.5
0.86
18
4.32
17.8
488
144
38.6
0.90
18
4.36
18.0
493
145
63
34.3
0.68
15
4.19
17.1
468
138
37.1
0.70
15
4.29
17.6
483
142
38.2
0.74
14
4.32
17.8
488
144
37.5
0.62
15
4.35
17.9
500
152
40.6
0.65
15
4.46
18.4
515
157
41.8
0.68
14
4.50
18.6
520
158
67
37.5
0.47
12
4.32
17.7
494
151
40.7
0.49
11
4.42
18.2
510
155
41.9
0.51
11
4.46
18.4
515
157
40.2
0.40
11
4.49
18.6
521
162
43.6
0.42
10
4.60
19.1
537
167
44.9
0.44
10
4.64
19.3
543
169
-
71
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
43.4
0.40
11
4.35
17.5
472
157
47.0
0.41
11
4.45
18.0
486
161
48.5
0.43
11
4.49
18.2
491
163
-
71
115ºF
Cooling Data — ANX130481A* / CA*F4860*6D*+EEP
SS-ANX13
SS-ANX13
www.amana-hac.com
42.5
0.92
26
3.29
12.2
248
107
46.1
0.96
25
3.36
12.5
256
110
47.5
1.00
24
3.39
12.6
258
111
MBh
S/T
∆T
1400 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1600 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1800 kW
Amps
HI PR
LO PR
59
41.8
0.88
24
3.26
12.1
246
106
45.3
0.91
24
3.34
12.4
253
109
46.7
0.96
23
3.36
12.5
256
110
MBh
S/T
∆T
1400 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1600 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1800 kW
Amps
HI PR
LO PR
Airflow
63
43.4
0.89
25
3.35
12.5
267
114
47.0
0.92
25
3.43
12.8
275
117
48.4
0.97
24
3.45
12.9
278
118
42.7
0.83
23
3.33
12.3
264
113
46.3
0.86
23
3.40
12.7
273
116
47.7
0.90
22
3.43
12.8
275
117
67
45.4
0.80
24
3.45
12.9
282
124
49.2
0.83
24
3.53
13.2
291
128
50.7
0.87
23
3.56
13.3
294
129
45.6
0.67
20
3.42
12.7
279
123
49.5
0.70
20
3.50
13.1
288
127
50.9
0.73
19
3.53
13.2
291
128
48.5
0.65
21
3.55
13.3
294
132
52.5
0.68
20
3.64
13.7
303
136
54.1
0.71
20
3.66
13.8
306
138
71
48.8
0.5
16
3.5
13.2
291.3
130.9
52.9
0.5
16
3.6
13.6
300.3
134.9
54.4
0.5
15
3.6
13.7
303.3
136.3
41.5
0.96
26
3.52
13.1
279
113
45.0
0.99
26
3.60
13.5
287
116
46.4
1.00
24
3.63
13.6
290
118
59
40.8
0.91
24
3.49
13.0
276
112
44.2
0.95
24
3.58
13.4
284
115
45.6
1.00
23
3.60
13.5
287
116
63
42.4
0.92
26
3.59
13.5
300
120
45.9
0.96
25
3.68
13.8
309
124
47.3
1.00
24
3.70
14.0
312
125
41.7
0.86
23
3.56
13.3
297
119
45.2
0.89
23
3.65
13.7
306
123
46.6
0.93
22
3.68
13.8
309
124
67
44.4
0.83
24
3.70
13.9
317
131
48.1
0.86
24
3.79
14.3
326
135
49.5
0.91
23
3.82
14.4
330
137
44.6
0.70
20
3.67
13.8
313
130
48.3
0.72
20
3.76
14.2
323
134
49.7
0.76
19
3.79
14.3
326
135
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
47.3
0.68
21
3.81
14.4
330
140
51.3
0.70
21
3.90
14.8
340
144
52.8
0.74
20
3.93
15.0
344
145
71
47.7
0.52
16
3.78
14.3
327
138
51.6
0.54
16
3.87
14.7
337
143
53.2
0.57
15
3.90
14.8
340
144
63
41.3
0.95
26
3.80
14.6
341
125
44.8
0.98
25
3.89
15.0
351
129
46.1
1.00
24
3.93
15.2
355
130
40.7
0.88
23
3.77
14.5
338
124
44.1
0.91
23
3.86
14.9
348
127
45.5
0.95
22
3.89
15.0
351
129
67
43.3
0.85
24
3.92
15.1
360
136
46.9
0.89
24
4.01
15.5
371
140
48.3
0.93
23
4.05
15.7
375
142
43.5
0.71
20
3.89
15.0
356
135
47.2
0.74
20
3.98
15.4
367
139
48.6
0.78
19
4.01
15.5
371
140
71
46.2
0.69
21
4.04
15.7
375
145
50.1
0.72
21
4.14
16.1
387
150
51.6
0.75
20
4.17
16.3
391
151
46.5
0.5
16
4.0
15.5
371.7
143.7
50.4
0.6
16
4.1
16.0
383.2
148.1
51.9
0.6
15
4.1
16.1
387.1
149.6
Shaded area reflects AHRI conditions
40.6
0.98
26
3.73
14.3
317
117
43.9
1.00
25
3.82
14.7
327
121
45.3
1.00
23
3.85
14.8
330
122
59
39.9
0.94
25
3.70
14.2
314
116
43.2
0.97
24
3.79
14.6
323
120
44.5
1.00
23
3.82
14.7
327
121
59
39.6
1.00
26
3.91
15.3
361
123
42.9
1.00
25
4.00
15.7
372
127
44.2
1.00
23
4.04
15.8
376
128
38.9
0.97
25
3.88
15.1
357
122
42.1
1.00
24
3.97
15.6
368
126
43.4
1.00
22
4.00
15.7
372
127
63
40.3
0.98
26
3.99
15.6
388
131
43.7
1.00
25
4.09
16.1
400
135
45.0
1.00
23
4.12
16.2
404
137
39.7
0.91
24
3.96
15.5
384
130
43.1
0.94
23
4.06
15.9
396
134
44.3
1.00
23
4.09
16.1
400
135
67
42.2
0.88
24
4.11
16.2
410
143
45.8
0.91
24
4.21
16.6
423
148
47.1
0.96
23
4.25
16.8
427
149
42.5
0.74
21
4.08
16.0
406
142
46.0
0.77
20
4.18
16.5
419
146
47.4
0.80
19
4.21
16.6
423
148
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
45.1
0.72
21
4.24
16.8
428
152
48.8
0.74
21
4.35
17.2
441
157
50.3
0.78
20
4.38
17.4
445
159
71
45.4
0.55
16
4.21
16.6
423
151
49.2
0.57
16
4.31
17.1
436
156
50.6
0.60
16
4.35
17.2
441
157
37.6
1.00
25
4.07
16.2
406
129
40.7
1.00
23
4.16
16.7
418
133
42.0
1.00
21
4.20
16.9
423
134
59
36.9
1.00
24
4.03
16.1
402
128
40.0
1.00
23
4.13
16.6
414
132
41.2
1.00
21
4.16
16.7
418
133
38.3
1.00
25
4.15
16.6
437
137
41.5
1.00
24
4.25
17.1
450
142
42.8
1.00
22
4.29
17.3
455
143
63
37.8
0.94
23
4.12
16.5
432
136
40.9
0.98
23
4.22
17.0
446
140
42.1
1.00
22
4.25
17.1
450
142
40.1
0.92
24
4.28
17.2
461
150
43.5
0.95
24
4.39
17.7
476
155
44.8
1.00
23
4.42
17.9
480
156
67
40.3
0.77
20
4.25
17.0
457
149
43.7
0.79
20
4.35
17.5
471
153
45.0
0.83
19
4.39
17.7
476
155
105ºF
34.8
1.00
23
4.20
17.2
448
134
37.7
1.00
22
4.30
17.7
462
138
38.9
1.00
20
4.34
17.9
467
139
59
34.2
1.01
23
4.17
17.1
444
132
37.1
1.00
21
4.27
17.5
458
136
38.2
1.00
20
4.30
17.7
462
138
35.5
1.00
23
4.29
17.6
483
142
38.5
1.00
22
4.39
18.1
498
147
39.6
1.00
20
4.43
18.3
503
148
63
35.0
0.95
22
4.25
17.5
478
141
37.9
0.98
21
4.36
18.0
493
145
39.0
1.00
20
4.39
18.1
498
147
37.2
0.92
23
4.42
18.2
510
155
40.3
0.96
22
4.53
18.8
525
160
41.5
1.00
21
4.57
18.9
531
162
67
37.4
0.77
19
4.39
18.1
505
154
40.5
0.80
19
4.50
18.6
520
158
41.7
0.84
18
4.53
18.8
525
160
39.7
0.75
20
4.56
18.9
532
165
43.0
0.78
19
4.68
19.5
548
170
44.3
0.81
18
4.72
19.7
553
172
71
39.9
0.58
15
4.53
18.8
526
164
43.3
0.60
15
4.64
19.3
543
169
44.6
0.63
14
4.68
19.5
548
170
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
42.8
0.74
21
4.42
17.9
481
160
46.4
0.77
21
4.53
18.4
496
165
47.8
0.81
20
4.56
18.5
501
166
71
43.1
0.6
16
4.4
17.7
476.3
158.2
46.7
0.6
16
4.5
18.2
491.1
163.1
48.1
0.6
15
4.5
18.4
496.0
164.7
115ºF
Cooling Data — ANX130481A* / CA*F4860*6D*+EEP (cont.)
19
20
www.amana-hac.com
55.1
0.79
23
4.06
15.4
262
106
55.1
0.79
23
4.06
15.4
262
106
57.1
0.84
20
4.13
15.7
267
109
MBh
S/T
∆T
1750 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1750 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
2250 kW
Amps
HI PR
LO PR
59
54.2
0.69
20
4.03
15.2
259
105
54.2
0.69
20
4.03
15.2
259
105
56.1
0.74
17
4.09
15.5
264
107
MBh
S/T
∆T
1750 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1750 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
2250 kW
Amps
HI PR
LO PR
Airflow
63
56.8
0.71
21
4.15
15.8
282
113
56.8
0.71
21
4.15
15.8
282
113
58.8
0.75
18
4.21
16.1
287
115
56.2
0.58
17
4.11
15.6
279
112
56.2
0.58
17
4.11
15.6
279
112
58.2
0.62
15
4.18
15.9
284
114
67
61.5
0.53
17
4.27
16.3
297
124
61.5
0.53
17
4.27
16.3
297
124
63.6
0.57
15
4.34
16.6
303
126
61.6
0.40
13
4.24
16.1
294
122
61.6
0.40
13
4.24
16.1
294
122
63.7
0.43
11
4.31
16.4
300
125
66.0
0.34
12
4.41
16.9
310
132
66.0
0.34
12
4.41
16.9
310
132
68.3
0.36
10
4.48
17.2
316
134
-
71
53.9
0.82
23
4.37
16.7
294
112
53.9
0.82
23
4.37
16.7
294
112
55.8
0.87
20
4.44
17.0
299
115
59
53.0
0.72
20
4.33
16.5
291
111
53.0
0.72
20
4.33
16.5
291
111
54.8
0.76
17
4.40
16.8
296
114
63
55.5
0.73
21
4.46
17.1
316
120
55.5
0.73
21
4.46
17.1
316
120
57.4
0.78
18
4.53
17.4
322
122
54.9
0.60
17
4.42
16.9
313
118
54.9
0.60
17
4.42
16.9
313
118
56.8
0.64
15
4.49
17.2
319
121
67
60.0
0.55
17
4.60
17.6
334
131
60.0
0.55
17
4.60
17.6
334
131
62.1
0.59
15
4.67
18.0
340
133
60.1
0.42
13
4.56
17.5
330
129
60.1
0.42
13
4.56
17.5
330
129
62.3
0.44
11
4.63
17.8
337
132
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
64.4
0.36
12
4.75
18.3
348
139
64.4
0.36
12
4.75
18.3
348
139
66.7
0.38
10
4.82
18.7
355
142
-
71
63
54.1
0.75
21
4.74
18.6
359
124
54.1
0.75
21
4.74
18.6
359
124
56.0
0.80
18
4.81
18.9
366
127
53.6
0.62
17
4.70
18.4
356
123
53.6
0.62
17
4.70
18.4
356
123
55.5
0.65
15
4.77
18.8
363
126
67
58.6
0.57
17
4.89
19.2
379
136
58.6
0.57
17
4.89
19.2
379
136
60.7
0.60
15
4.97
19.6
387
138
58.7
0.43
13
4.85
19.0
376
134
58.7
0.43
13
4.85
19.0
376
134
60.8
0.45
11
4.92
19.4
383
137
62.9
0.36
12
5.04
20.0
396
145
62.9
0.36
12
5.04
20.0
396
145
65.1
0.39
10
5.13
20.3
404
147
-
71
59
51.3
0.86
23
4.87
19.4
380
123
51.3
0.86
23
4.87
19.4
380
123
53.1
0.92
20
4.95
19.8
388
125
50.4
0.76
20
4.83
19.2
376
122
50.4
0.76
20
4.83
19.2
376
122
52.2
0.81
17
4.91
19.6
384
124
Shaded area reflects ACCA (TVA) conditions
52.6
0.84
23
4.64
18.1
334
117
52.6
0.84
23
4.64
18.1
334
117
54.4
0.89
20
4.71
18.5
341
119
59
51.7
0.74
20
4.60
18.0
331
116
51.7
0.74
20
4.60
18.0
331
116
53.5
0.78
17
4.67
18.3
337
118
63
52.8
0.77
21
4.98
19.9
409
131
52.8
0.77
21
4.98
19.9
409
131
54.7
0.82
18
5.06
20.3
417
133
52.3
0.64
17
4.94
19.7
405
129
52.3
0.64
17
4.94
19.7
405
129
54.1
0.68
15
5.02
20.1
413
132
67
57.2
0.59
18
5.14
20.6
432
143
57.2
0.59
18
5.14
20.6
432
143
59.2
0.62
15
5.22
21.0
441
145
57.3
0.44
13
5.10
20.4
428
141
57.3
0.44
13
5.10
20.4
428
141
59.3
0.47
11
5.18
20.8
436
144
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
61.4
0.38
12
5.31
21.4
451
152
61.4
0.38
12
5.31
21.4
451
152
63.5
0.40
10
5.40
21.8
460
155
-
71
48.7
0.90
23
5.07
20.7
428
129
48.7
0.90
23
5.07
20.7
428
129
50.4
0.95
20
5.16
21.1
436
131
59
47.9
0.79
20
5.03
20.5
423
127
47.9
0.79
20
5.03
20.5
423
127
49.6
0.84
17
5.12
20.9
432
130
50.2
0.80
21
5.19
21.2
460
137
50.2
0.80
21
5.19
21.2
460
137
51.9
0.85
18
5.27
21.6
470
140
63
49.7
0.66
17
5.14
21.0
456
135
49.7
0.66
17
5.14
21.0
456
135
51.4
0.70
15
5.23
21.4
465
138
54.3
0.61
17
5.35
21.9
486
149
54.3
0.61
17
5.35
21.9
486
149
56.2
0.65
15
5.44
22.3
496
152
67
54.4
0.46
13
5.31
21.7
481
148
54.4
0.46
13
5.31
21.7
481
148
56.3
0.49
11
5.40
22.1
491
151
105ºF
45.1
0.91
21
5.25
21.9
473
133
45.1
0.91
21
5.25
21.9
473
133
46.7
0.96
18
5.34
22.4
482
136
59
44.4
0.80
19
5.21
21.7
468
132
44.4
0.80
19
5.21
21.7
468
132
45.9
0.85
16
5.29
22.1
477
134
46.5
0.81
20
5.36
22.5
509
142
46.5
0.81
20
5.36
22.5
509
142
48.1
0.86
17
5.45
22.9
519
144
63
46.0
0.66
16
5.32
22.3
504
140
46.0
0.66
16
5.32
22.3
504
140
47.6
0.71
14
5.41
22.7
514
143
50.3
0.61
16
5.54
23.3
537
155
50.3
0.61
16
5.54
23.3
537
155
52.1
0.65
14
5.63
23.7
548
158
67
50.4
0.46
12
5.49
23.0
532
153
50.4
0.46
12
5.49
23.0
532
153
52.2
0.49
10
5.58
23.5
542
156
54.0
0.39
11
5.72
24.2
560
165
54.0
0.39
11
5.72
24.2
560
165
55.9
0.42
10
5.82
24.6
571
168
-
71
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
58.3
0.39
12
5.53
22.8
507
159
58.3
0.39
12
5.53
22.8
507
159
60.3
0.42
10
5.62
23.2
517
162
-
71
115ºF
Cooling Data — ANX130601A* / CA*F4961*6D*+EEP
SS-ANX13
SS-ANX13
www.amana-hac.com
57.1
0.91
27
4.13
15.7
267
109
57.1
0.91
27
4.13
15.7
267
109
59.1
0.96
23
4.19
16.0
272
111
MBh
S/T
∆T
1750 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1750 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
2250 kW
Amps
HI PR
LO PR
59
56.1
0.86
25
4.09
15.5
264
107
56.1
0.86
25
4.09
15.5
264
107
58.1
0.92
22
4.16
15.8
270
110
MBh
S/T
∆T
kW
1750
Amps
HI PR
LO PR
MBh
S/T
∆T
kW
1750
Amps
HI PR
LO PR
MBh
S/T
∆T
2250 kW
Amps
HI PR
LO PR
Airflow
63
58.2
0.87
27
4.21
16.1
287
116
58.2
0.87
27
4.21
16.1
287
116
60.3
0.93
23
4.28
16.4
293
118
57.4
0.81
24
4.18
15.9
284
114
57.4
0.81
24
4.18
15.9
284
114
59.4
0.86
21
4.24
16.2
290
117
67
61.0
0.79
25
4.34
16.6
303
126
61.0
0.79
25
4.34
16.6
303
126
63.1
0.84
22
4.41
16.9
309
129
61.3
0.66
21
4.31
16.4
300
125
61.3
0.66
21
4.31
16.4
300
125
63.4
0.70
18
4.38
16.7
306
127
65.0
0.64
22
4.48
17.2
316
134
65.0
0.64
22
4.48
17.2
316
134
67.3
0.68
19
4.55
17.5
323
137
71
65.5
0.5
17
4.4
17.1
313.2
133.0
65.5
0.5
17
4.4
17.1
313.2
133.0
67.8
0.5
15
4.5
17.4
319.5
135.6
55.8
0.94
28
4.44
17.0
300
115
55.8
0.94
28
4.44
17.0
300
115
57.7
1.00
24
4.51
17.3
305
117
59
54.8
0.90
26
4.40
16.8
297
114
54.8
0.90
26
4.40
16.8
297
114
56.7
0.95
22
4.47
17.1
302
116
63
56.9
0.91
27
4.53
17.4
322
122
56.9
0.91
27
4.53
17.4
322
122
58.8
0.96
23
4.60
17.7
329
124
56.0
0.84
25
4.49
17.2
319
121
56.0
0.84
25
4.49
17.2
319
121
58.0
0.89
21
4.57
17.6
326
123
67
59.6
0.82
26
4.67
18.0
340
133
59.6
0.82
26
4.67
18.0
340
133
61.6
0.87
22
4.75
18.3
347
136
59.9
0.68
22
4.64
17.8
337
132
59.9
0.68
22
4.64
17.8
337
132
61.9
0.73
18
4.71
18.1
344
135
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
63.5
0.66
22
4.82
18.7
355
142
63.5
0.66
22
4.82
18.7
355
142
65.8
0.71
19
4.90
19.0
362
145
71
64.0
0.51
17
4.78
18.5
351
140
64.0
0.51
17
4.78
18.5
351
140
66.2
0.54
15
4.86
18.8
358
143
63
55.5
0.93
27
4.81
18.9
367
127
55.5
0.93
27
4.81
18.9
367
127
57.4
0.99
23
4.89
19.3
374
129
54.7
0.86
25
4.77
18.8
363
126
54.7
0.86
25
4.77
18.8
363
126
56.6
0.92
21
4.85
19.1
370
128
67
58.1
0.84
26
4.97
19.6
387
138
58.1
0.84
26
4.97
19.6
387
138
60.2
0.89
22
5.05
19.9
395
141
58.4
0.70
22
4.93
19.4
383
137
58.4
0.70
22
4.93
19.4
383
137
60.5
0.75
18
5.01
19.8
391
140
71
62.0
0.68
22
5.13
20.3
404
147
62.0
0.68
22
5.13
20.3
404
147
64.2
0.72
19
5.21
20.7
412
150
62.5
0.5
17
5.1
20.1
399.7
146.0
62.5
0.5
17
5.1
20.1
399.7
146.0
64.6
0.6
15
5.2
20.5
407.7
148.9
Shaded area reflects AHRI conditions
54.5
0.96
28
4.71
18.5
341
119
54.5
0.96
28
4.71
18.5
341
119
56.4
1.00
23
4.79
18.8
347
122
59
53.5
0.92
26
4.67
18.3
337
118
53.5
0.92
26
4.67
18.3
337
118
55.4
1.00
23
4.75
18.6
344
120
59
53.1
0.99
28
4.95
19.8
388
125
53.1
0.99
28
4.95
19.8
388
125
55.0
1.00
22
5.03
20.1
396
128
52.2
0.95
26
4.91
19.6
384
124
52.2
0.95
26
4.91
19.6
384
124
54.0
1.00
22
4.99
20.0
392
126
63
54.2
0.96
27
5.06
20.3
417
133
54.2
0.96
27
5.06
20.3
417
133
56.0
1.00
23
5.14
20.7
426
136
53.4
0.89
25
5.02
20.1
413
132
53.4
0.89
25
5.02
20.1
413
132
55.2
0.95
21
5.10
20.5
422
135
67
56.7
0.87
26
5.22
21.0
441
145
56.7
0.87
26
5.22
21.0
441
145
58.7
0.92
22
5.31
21.4
450
148
57.0
0.72
22
5.18
20.8
437
144
57.0
0.72
22
5.18
20.8
437
144
59.0
0.77
19
5.27
21.2
445
147
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
60.5
0.70
22
5.40
21.8
460
155
60.5
0.70
22
5.40
21.8
460
155
62.6
0.75
19
5.49
22.2
469
158
71
60.9
0.54
17
5.35
21.6
455
153
60.9
0.54
17
5.35
21.6
455
153
63.1
0.58
15
5.44
22.0
464
156
50.5
1.00
27
5.16
21.1
436
131
50.5
1.00
27
5.16
21.1
436
131
52.2
1.00
21
5.24
21.5
445
134
59
49.6
0.98
26
5.12
20.9
432
130
49.6
0.98
26
5.12
20.9
432
130
51.3
1.00
21
5.20
21.3
441
133
51.4
1.00
27
5.27
21.6
470
140
51.4
1.00
27
5.27
21.6
470
140
53.2
1.00
22
5.36
22.0
479
142
63
50.7
0.92
25
5.23
21.4
465
138
50.7
0.92
25
5.23
21.4
465
138
52.5
1.00
21
5.32
21.8
474
141
53.9
0.90
25
5.44
22.3
496
152
53.9
0.90
25
5.44
22.3
496
152
55.8
0.96
22
5.53
22.8
506
155
67
54.2
0.75
21
5.40
22.1
491
151
54.2
0.75
21
5.40
22.1
491
151
56.0
0.80
18
5.49
22.6
501
154
105ºF
46.7
1.00
25
5.34
22.4
482
136
46.7
1.00
25
5.34
22.4
482
136
48.4
1.00
20
5.42
22.8
492
138
59
45.9
0.99
24
5.29
22.2
477
134
45.9
0.99
24
5.29
22.2
477
134
47.6
1.00
19
5.38
22.6
487
137
47.7
1.00
25
5.45
22.9
519
144
47.7
1.00
25
5.45
22.9
519
144
49.3
1.00
20
5.55
23.4
529
147
63
46.9
0.93
23
5.41
22.7
514
143
46.9
0.93
23
5.41
22.7
514
143
48.6
1.00
20
5.50
23.1
524
146
49.9
0.91
24
5.63
23.7
548
158
49.9
0.91
24
5.63
23.7
548
158
51.7
0.96
20
5.73
24.2
559
161
67
50.2
0.76
20
5.59
23.5
543
156
50.2
0.76
20
5.59
23.5
543
156
51.9
0.81
17
5.68
23.9
553
159
53.2
0.74
21
5.82
24.6
572
168
53.2
0.74
21
5.82
24.6
572
168
55.1
0.78
18
5.92
25.1
583
171
71
53.6
0.57
16
5.77
24.4
566
166
53.6
0.57
16
5.77
24.4
566
166
55.5
0.60
14
5.87
24.9
577
170
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
57.5
0.73
22
5.63
23.2
517
162
57.5
0.73
22
5.63
23.2
517
162
59.5
0.77
19
5.72
23.7
528
166
71
57.9
0.6
17
5.6
23.0
512.2
160.7
57.9
0.6
17
5.6
23.0
512.2
160.7
59.9
0.6
15
5.7
23.4
522.4
163.9
115ºF
Cooling Data — ANX130601A* / CA*F4961*6D*+EEP (cont.)
21
22
www.amana-hac.com
56.3
0.78
23
4.03
15.7
252
101
54.7
0.74
25
4.00
15.5
249
100
56.6
0.79
18
4.06
15.8
254
102
MBh
S/T
∆T
1750 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1500 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
2250 kW
Amps
HI PR
LO PR
59
55.4
0.68
20
4.00
15.5
249
100
53.8
0.65
21
3.97
15.4
247
99
55.6
0.69
16
4.03
15.7
252
101
MBh
S/T
∆T
1750 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1500 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
2250 kW
Amps
HI PR
LO PR
Airflow
63
58.0
0.69
21
4.12
16.1
271
107
56.3
0.66
23
4.09
15.9
268
106
58.3
0.70
17
4.15
16.2
274
108
57.4
0.57
17
4.08
15.9
268
106
55.7
0.54
19
4.05
15.8
266
105
57.7
0.58
14
4.12
16.1
271
107
67
62.7
0.52
17
4.25
16.6
286
117
60.9
0.50
19
4.21
16.5
283
116
63.1
0.53
14
4.28
16.8
289
118
62.9
0.39
13
4.21
16.4
283
116
61.0
0.38
14
4.18
16.3
281
115
63.2
0.40
10
4.25
16.6
286
117
67.3
0.34
12
4.39
17.2
299
124
65.4
0.32
13
4.35
17.1
296
123
67.7
0.34
9
4.42
17.4
302
126
-
71
55.0
0.80
23
4.34
17.0
283
106
53.4
0.77
25
4.31
16.8
280
105
55.3
0.81
18
4.38
17.1
285
107
59
54.1
0.71
20
4.31
16.8
280
105
52.5
0.67
22
4.27
16.7
277
104
54.3
0.72
16
4.34
17.0
283
106
63
56.6
0.72
21
4.44
17.4
304
113
55.0
0.69
23
4.40
17.2
301
112
56.9
0.73
17
4.47
17.6
307
114
56.1
0.59
17
4.40
17.2
301
112
54.4
0.56
19
4.37
17.1
298
111
56.3
0.60
14
4.44
17.4
304
113
67
61.3
0.54
18
4.58
18.0
321
123
59.5
0.52
19
4.54
17.8
318
122
61.6
0.55
14
4.62
18.2
324
125
61.4
0.41
13
4.54
17.8
318
122
59.6
0.39
14
4.51
17.7
315
121
61.7
0.41
10
4.58
18.0
321
123
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
65.8
0.35
12
4.73
18.7
335
131
63.9
0.33
13
4.69
18.5
332
130
66.1
0.35
10
4.77
18.9
338
133
-
71
63
55.3
0.74
21
4.72
19.0
346
118
53.7
0.70
23
4.68
18.8
343
116
55.5
0.75
17
4.76
19.1
349
119
54.7
0.61
17
4.68
18.8
342
116
53.1
0.58
19
4.64
18.6
339
115
55.0
0.61
14
4.72
19.0
346
118
67
59.8
0.56
18
4.88
19.6
365
128
58.1
0.53
19
4.84
19.4
362
127
60.1
0.57
14
4.92
19.8
369
130
59.9
0.42
13
4.84
19.4
362
127
58.2
0.40
14
4.80
19.2
358
126
60.2
0.43
10
4.88
19.6
365
128
64.2
0.36
12
5.04
20.4
381
137
62.3
0.34
13
5.00
20.2
377
135
64.5
0.36
10
5.08
20.6
385
138
-
71
59
52.4
0.85
23
4.86
19.8
366
116
50.9
0.81
25
4.82
19.6
363
115
52.6
0.86
19
4.90
20.0
370
117
51.5
0.75
20
4.82
19.6
362
115
50.0
0.71
22
4.78
19.4
359
114
51.8
0.76
16
4.86
19.8
366
116
Shaded area reflects ACCA (TVA) conditions
53.7
0.82
23
4.62
18.5
321
110
52.1
0.79
25
4.58
18.3
318
109
53.9
0.84
18
4.66
18.7
325
112
59
52.8
0.72
20
4.58
18.3
318
109
51.3
0.69
22
4.54
18.1
315
108
53.0
0.73
16
4.62
18.5
321
110
63
53.9
0.76
22
4.97
20.3
394
123
52.4
0.73
23
4.93
20.1
390
122
54.2
0.77
17
5.01
20.5
398
125
53.4
0.62
18
4.93
20.1
390
122
51.8
0.60
19
4.89
19.9
386
121
53.6
0.63
14
4.97
20.3
394
123
67
58.4
0.58
18
5.14
21.0
416
135
56.7
0.55
19
5.09
20.8
412
133
58.7
0.58
14
5.18
21.2
420
136
58.5
0.43
13
5.09
20.8
412
133
56.8
0.41
14
5.05
20.6
408
132
58.8
0.44
11
5.13
21.0
416
135
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
62.6
0.37
12
5.31
21.8
434
144
60.8
0.35
13
5.26
21.6
430
142
63.0
0.38
10
5.35
22.0
438
145
-
71
49.8
0.88
23
5.07
21.1
412
122
48.3
0.84
25
5.03
20.9
408
120
50.0
0.89
18
5.11
21.3
416
123
59
48.9
0.78
20
5.03
20.9
408
120
47.5
0.74
22
4.99
20.7
404
119
49.2
0.79
16
5.07
21.1
412
122
51.2
0.79
21
5.18
21.6
443
129
49.7
0.75
23
5.14
21.4
439
128
51.5
0.80
17
5.23
21.8
448
131
63
50.7
0.65
17
5.14
21.4
439
128
49.2
0.62
19
5.10
21.2
434
127
51.0
0.66
14
5.18
21.6
443
129
55.5
0.60
17
5.36
22.4
468
141
53.8
0.57
19
5.31
22.2
463
140
55.7
0.61
14
5.40
22.6
473
143
67
55.6
0.45
13
5.31
22.2
463
140
53.9
0.43
14
5.27
22.0
459
138
55.8
0.46
10
5.36
22.4
468
141
105ºF
46.1
0.89
22
5.25
22.4
455
126
44.7
0.85
23
5.20
22.2
451
125
46.3
0.90
17
5.29
22.6
460
127
59
45.3
0.78
19
5.20
22.2
451
125
44.0
0.75
20
5.16
22.0
446
123
45.5
0.79
15
5.25
22.4
455
126
47.5
0.80
20
5.37
23.0
490
134
46.1
0.76
21
5.32
22.7
485
133
47.7
0.81
16
5.41
23.2
495
135
63
47.0
0.65
16
5.32
22.7
485
132
45.6
0.62
17
5.28
22.5
480
131
47.2
0.66
13
5.37
23.0
490
134
51.4
0.60
16
5.55
23.8
517
146
49.9
0.57
18
5.50
23.5
512
145
51.6
0.61
13
5.59
24.0
522
148
67
51.5
0.45
12
5.50
23.5
512
145
50.0
0.43
13
5.45
23.3
507
143
51.7
0.46
10
5.55
23.7
517
146
55.1
0.39
11
5.74
24.7
539
156
53.5
0.37
12
5.69
24.4
534
154
55.4
0.39
9
5.79
24.9
545
157
-
71
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
59.5
0.38
12
5.54
23.3
488
150
57.8
0.37
13
5.49
23.0
483
149
59.8
0.39
10
5.59
23.5
493
152
-
71
115ºF
Cooling Data — ANX130611A* / CA*F4961*6D*+EEP
SS-ANX13
SS-ANX13
www.amana-hac.com
58.3
0.89
27
4.10
16.0
257
103
56.6
0.85
29
4.06
15.8
254
102
58.6
0.90
22
4.13
16.1
260
104
MBh
S/T
∆T
1750 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1500 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
2250 kW
Amps
HI PR
LO PR
59
57.3
0.85
26
4.06
15.8
254
102
55.6
0.81
28
4.03
15.7
252
101
57.6
0.86
20
4.10
16.0
257
103
MBh
S/T
∆T
1750 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
1500 kW
Amps
HI PR
LO PR
MBh
S/T
∆T
2250 kW
Amps
HI PR
LO PR
Airflow
63
59.4
0.86
27
4.19
16.4
277
109
57.7
0.82
29
4.15
16.2
274
108
59.7
0.87
21
4.22
16.5
279
110
58.6
0.80
25
4.15
16.2
274
108
56.9
0.76
26
4.12
16.1
271
107
58.8
0.81
19
4.18
16.4
277
109
67
62.2
0.78
25
4.32
16.9
292
119
60.4
0.74
27
4.28
16.8
289
118
62.5
0.79
20
4.35
17.1
295
120
62.6
0.65
21
4.28
16.8
289
118
60.7
0.62
23
4.25
16.6
286
117
62.9
0.66
17
4.32
16.9
292
119
66.4
0.63
22
4.46
17.6
305
127
64.5
0.60
24
4.42
17.4
302
126
66.7
0.64
17
4.49
17.7
308
128
71
66.9
0.5
17
4.4
17.4
301.6
125.7
64.9
0.5
18
4.4
17.2
298.6
124.5
67.2
0.5
14
4.5
17.6
304.6
127.0
56.9
0.92
28
4.42
17.3
288
108
55.3
0.88
30
4.38
17.1
286
107
57.2
0.94
22
4.45
17.5
291
110
59
56.0
0.88
26
4.38
17.1
286
107
54.3
0.84
28
4.34
17.0
283
106
56.2
0.89
21
4.42
17.3
288
108
63
58.1
0.89
27
4.51
17.7
310
115
56.4
0.85
29
4.48
17.6
307
114
58.3
0.90
22
4.55
17.9
313
117
57.2
0.83
25
4.48
17.6
307
114
55.5
0.79
27
4.44
17.4
304
113
57.5
0.84
20
4.51
17.7
310
115
67
60.8
0.80
26
4.66
18.3
328
126
59.0
0.77
28
4.62
18.2
324
125
61.1
0.82
20
4.70
18.5
331
127
61.1
0.67
22
4.62
18.2
324
125
59.3
0.64
23
4.58
18.0
321
123
61.4
0.68
17
4.66
18.3
328
126
75ºF
IDB: Entering Indoor Dry Bulb Temperature
High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
64.9
0.65
22
4.81
19.0
342
134
63.0
0.62
24
4.77
18.9
338
133
65.2
0.66
18
4.85
19.2
345
135
71
65.3
0.50
17
4.77
18.9
338
133
63.4
0.48
19
4.73
18.7
335
132
65.6
0.51
14
4.81
19.0
342
134
63
56.7
0.91
27
4.80
19.3
353
120
55.0
0.87
29
4.76
19.1
349
119
56.9
0.93
22
4.84
19.5
356
121
55.8
0.85
25
4.76
19.1
349
119
54.2
0.81
27
4.72
19.0
346
118
56.1
0.86
20
4.80
19.3
353
120
67
59.4
0.82
26
4.96
20.0
373
131
57.6
0.79
28
4.92
19.8
369
130
59.6
0.84
20
5.00
20.2
376
132
59.6
0.69
22
4.92
19.8
369
130
57.9
0.66
23
4.88
19.6
365
128
59.9
0.70
17
4.96
20.0
373
131
71
63.3
0.67
22
5.12
20.7
389
139
61.5
0.64
24
5.08
20.6
385
138
63.6
0.68
18
5.17
20.9
393
141
63.8
0.5
17
5.1
20.6
384.9
138.0
61.9
0.5
19
5.0
20.4
381.0
136.7
64.1
0.5
14
5.1
20.7
388.7
139.4
Shaded area reflects AHRI conditions
55.6
0.95
28
4.70
18.8
328
113
54.0
0.90
30
4.66
18.7
325
112
55.9
0.96
22
4.74
19.0
331
114
59
54.6
0.90
26
4.66
18.7
325
112
53.0
0.86
28
4.62
18.5
321
110
54.9
0.92
21
4.70
18.8
328
113
59
54.2
0.98
28
4.95
20.2
374
118
52.7
0.93
30
4.90
20.0
370
117
54.5
0.99
22
4.99
20.4
377
120
53.3
0.93
26
4.90
20.0
370
117
51.8
0.89
28
4.86
19.8
366
116
53.6
0.95
21
4.94
20.2
373
118
63
55.3
0.94
27
5.06
20.7
402
126
53.7
0.90
30
5.01
20.5
398
125
55.6
0.96
22
5.10
20.9
406
127
54.5
0.87
25
5.01
20.5
398
125
52.9
0.83
27
4.97
20.3
394
123
54.7
0.89
20
5.06
20.7
402
126
67
57.9
0.85
26
5.22
21.4
424
138
56.2
0.81
28
5.18
21.2
420
136
58.2
0.86
21
5.27
21.6
429
139
58.2
0.71
22
5.18
21.2
420
136
56.5
0.68
24
5.14
21.0
416
135
58.5
0.72
17
5.22
21.4
424
137
Outdoor Ambient Temperature
85ºF
95ºF
Entering Indoor Wet Bulb Temperature
61.8
0.69
22
5.40
22.2
443
146
60.0
0.66
24
5.35
22.0
438
145
62.1
0.70
18
5.45
22.4
447
148
71
62.2
0.53
17
5.35
22.0
438
145
60.4
0.51
19
5.31
21.8
434
144
62.5
0.54
14
5.40
22.2
443
146
51.5
1.00
27
5.16
21.5
420
124
50.0
0.97
30
5.11
21.3
416
123
51.8
1.00
21
5.20
21.7
424
125
59
50.6
0.97
26
5.11
21.3
416
123
49.2
0.92
28
5.07
21.1
412
122
50.9
1.00
21
5.16
21.5
420
124
52.5
0.98
27
5.27
22.1
452
132
51.0
0.93
29
5.23
21.8
448
131
52.8
0.99
21
5.32
22.3
457
133
63
51.7
0.91
25
5.23
21.8
448
131
50.2
0.87
27
5.18
21.6
443
129
52.0
0.92
20
5.27
22.1
452
132
55.0
0.88
26
5.45
22.8
478
144
53.4
0.84
28
5.40
22.6
473
143
55.3
0.90
20
5.49
23.0
482
146
67
55.3
0.74
21
5.40
22.6
473
143
53.7
0.70
23
5.36
22.4
468
141
55.6
0.75
17
5.45
22.8
477
144
105ºF
47.7
1.00
25
5.34
22.8
464
128
46.3
0.98
28
5.29
22.6
460
127
48.0
1.00
20
5.38
23.0
469
130
59
46.9
1.00
25
5.29
22.6
460
127
45.5
0.93
26
5.25
22.4
455
126
47.1
1.00
19
5.34
22.8
464
128
48.7
0.99
25
5.46
23.4
500
137
47.2
0.94
27
5.41
23.2
495
135
48.9
1.00
20
5.51
23.6
505
138
63
47.9
0.92
23
5.41
23.2
495
135
46.5
0.87
25
5.37
23.0
490
134
48.2
0.93
18
5.46
23.4
500
137
51.0
0.89
24
5.64
24.2
528
149
49.5
0.85
26
5.59
24.0
522
148
51.2
0.90
19
5.69
24.4
533
151
67
51.2
0.75
20
5.59
24.0
522
148
49.7
0.71
22
5.55
23.8
517
146
51.5
0.76
16
5.64
24.2
528
149
54.4
0.72
21
5.84
25.2
550
159
52.8
0.69
22
5.79
24.9
545
157
54.6
0.73
16
5.89
25.4
556
160
71
54.7
0.56
16
5.79
24.9
545
157
53.2
0.53
17
5.74
24.7
539
156
55.0
0.56
13
5.84
25.2
550
159
Amps = outdoor unit amps (comp.+fan)
kW = Total system power
58.7
0.72
22
5.63
23.7
498
153
57.0
0.68
24
5.59
23.5
493
152
59.0
0.73
18
5.68
23.9
503
155
71
59.1
0.6
17
5.6
23.5
493.1
152.0
57.4
0.5
19
5.5
23.3
488.2
150.5
59.4
0.6
14
5.6
23.7
498.0
153.5
115ºF
Cooling Data — ANX130611A* / CA*F4961*6D*+EEP (cont.)
23
24
H
W
D
26
29
29
ANX130361A*
ANX130421A*
ANX130481A*
www.amana-hac.com
35½
29
29
29
26
26
26
26
26
D"
Dimensions
H"
38¼
40
36¼
36¼
27½
32½
27½
27½
27½
ANX13
Goodman Company, L.P.
29
26
ANX130301B*
35½
26
ANX130301A*
ANX130611A*
26
ANX130241**
ANX130601A*
26
W"
ANX130181A*
Model
Dimensions
SS-ANX13
SS-ANX13
www.amana-hac.com
L2
L1
1
SR
IO
CM
AUX
MAIN
BL
BK
YL
RD
IO
BK
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
BK
BR
PU
ALTERNATE DOUBLE
POLE CONTACTOR
T2
T1
YL
2
5
BK
CONTROL BOX
C
AUX
S
YL/PK
C
L2
T2
LPS
YL
PU
L1
T1
⚠ Warning
R
YL
COMP
MAIN
RD
BL
BK
BK
BK
SA
(IF USED)
NOTE 2
RD
YL
H
C
RD
F
RCCF
BL
YL
LVJB
NOTE 1
C
T1
C
IO
X
AU
SR
S
LPS
CM
IO
COMP
M
AI
N
R
5
2
C
M
AI
N
SC
C
(IF USED)
SA
RCCF
X
AU
F
H
1
OUTDOOR POWER SUPPLY
SEE RATING PLATE
T2
C
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
⚡
L2
0140R00331-A
COMPONENT CODE
Y
C
C --------------- CONTACTOR
NOTE 1
CSM -------- CORESENSE MODULE
CM ------------ OUTDOOR FAN MOTOR
NOTES:
COMP -------- COMPRESSOR
1) TO INDOOR UNIT LOW VOLTAGE
TERMINAL BLOCK & INDOOR
IO -------------- INTERNAL OVERLOAD
THERMOSTAT.
LVJB ---------- LOW VOLTAGE JUNCTION BOX
2) START ASSIST FACTORY
RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN
EQUIPPED WHEN REQUIRED.
SA ------------- START ASSIST
3) USE COPPER CONDUCTORS
ONLY.
SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
USE N.E.C.
SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
CLASS 2 WIRE
LPS ------------ LOW PRESSURE SWITCH
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
L1
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
YL/PK
EQUIPMENT GROUND
SEE
NOTE 3
RD
RD
RD
BR
YL
RD
RD
SC
C
BL
LVJB
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW
YL/PK ---------- YELLOW/PINK STRIPE
Y
ALTERNATE DOUBLE
POLE CONTACTOR ONLY
YL/PK
Wiring Diagram — ANX130181A*-301A*
25
26
www.amana-hac.com
YL
T2
L2
T1
L1
1
SR
BL
IO
CM
AUX
MAIN
ALTERNATE DOUBLE
POLE CONTACTOR
2
5
BK
BK
BR
PU
BK
IO
C
MAIN
R
AUX
BL
S
BL/PK
COMP
BL/PK
BL/PK
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
YL
RD
CONTROL BOX
L1
C
RD
RCCF
F
HERM
RD
SA
(IF USED)
NOTE 2
BR
RD
RD
YL
YL
YL
BL
YL
EQUIPMENT GROUND
RD
PU
RD
RD
⚠ Warning
C
L2
T2
BK
HPS
BK
T1
BK
SC
C
BL
NOTE 1
L1
C
M
AI
N
X
AU
HPS
CM
IO
IO
Y
SR
S
AI
N
R
COMP
X
AU
M
5
C
2
F
H
1
⚡
USE N.E.C. CLASS 2 WIRE
SC
C
C
(IF USED)
SA
RCCF
OUTDOOR POWER SUPPLY
SEE RATING PLATE
T2
0140R00258-B
NOTES:
1) TO INDOOR UNIT LOW VOLTAGE
TERMINAL BLOCK AND INDOOR
THERMOSTAT
2) START ASSIST FACTORY
EQUIPPED WHEN REQUIRED.
3) USE COPPER CONDUCTORS ONLY.
T1
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
COMPONENT CODE
C --------------- CONTACTOR
CM ------------ OUTDOOR FAN MOTOR
COMP -------- COMPRESSOR
HPS ----------- HIGH PRESSURE SWITCH
IO -------------- INTERNAL OVERLOAD
LVJB ---------- LOW VOLTAGE JUNCTION BOX
RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN
SA ------------- START ASSIST
SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BL/PK ---------- BLUE/PINK STRIPE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL ---------------- YELLOW
Y
BL/PK
ALTERNATE DOUBLE
POLE CONTACTOR ONLY
LVJB
C
L2
Wiring Diagram — ANX130181B*-0301B*
SS-ANX13
SS-ANX13
www.amana-hac.com
YL
T2
L2
T1
L1
1
SR
BL
IO
CM
AUX
MAIN
ALTERNATE DOUBLE
POLE CONTACTOR
2
5
BK
YL
BK
C
R
AUX
MAIN
BL
YL
COMP
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
BK
BR
PU
RD
CONTROL BOX
L1
C
L2
T2
BK
C
RD
F
RCCF
HERM
RD
SA
(IF USED)
NOTE 2
BR
RD
RD
YL
YL
YL
BL
YL
L1
C
T1
C
CM
IO
IO
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
COMPONENT CODE
C --------------- CONTACTOR
CM ------------ OUTDOOR FAN MOTOR
COMP -------- COMPRESSOR
IO -------------- INTERNAL OVERLOAD
LVJB ---------- LOW VOLTAGE JUNCTION BOX
RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN
SA ------------- START ASSIST
SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
NOTE 1
M
AI
N
X
AU
S
AI
N
R
C
2
F
1
C
SA
C
(IF USED)
RCCF
SC
H
T2
C
⚡
0140R00015P-A
USE N.E.C. CLASS 2 WIRE
NOTES:
1) TO INDOOR UNIT LOW VOLTAGE
TERMINAL BLOCK AND INDOOR
THERMOSTAT
2) START ASSIST FACTORY
EQUIPPED WHEN REQUIRED.
Y
SR
COMP
X
AU
M
5
OUTDOOR POWER SUPPLY
SEE RATING PLATE
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
EQUIPMENT GROUND
USE COPPER
CONDUCTORS ONLY
RD
PU
RD
RD
⚠ Warning
S
BK
T1
BK
SC
C
Y
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL ---------------- YELLOW
BL
YL
ALTERNATE DOUBLE
POLE CONTACTOR ONLY
LVJB
L2
Wiring Diagram — ANX130361**-0611**
27
Accessories
Model
Description
ANX13
018**
ABK-20
Anchor Bracket Kit ^
ABK-21
Anchor Bracket Kit ^
X
ANX13
024**
ANX13
030**
ANX13
036**
ANX13
042**
ANX13
048**
ANX13
060**
ANX13
061**
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
ASC-01
Anti-Short Cycle Kit
X
X
X
X
CSR-U-1
Hard-start Kit
X
X
X
X
CSR-U-2
Hard-start Kit
CSR-U-3
Hard-start Kit
X
X
X
FSK01A¹
Freeze Protection Kit
X
X
X
X
X
X
X
X
X
X
X
X
LSK02A²
Liquid Line Solenoid Kit
X
X
X
X
0130R00000S
Low-Pressure Switch Kit
X
X
X
X
X
X
X
X
LAKT01A
Low-Ambient Kit
X
X
X
X
X
X
X
X
TX2N4A²
TXV Kit
X
X
TX3N4²
TXV Kit
X
X
TX5N4²
TXV Kit
X
X
X
X
^
¹
²
Contains 20 brackets; four brackets needed to anchor unit to pad
Installed on indoor coil
Field-installed, non-bleed, expansion valve kit — Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit.
All AHRI system ratings are accessible in the System Configurator tool via PartnerLink.
28
www.amana-hac.com
SS-ANX13

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project