advertisement
▼
Scroll to page 2
of 28
ANX13 Energy-Efficient Split System Air Conditioner Up to 14 SEER / 12 EER Cooling Capacity: 17,800 - 56,500 BTU/h Contents Nomenclature......................................... 2 Product Specifications............................ 3 Expanded Cooling Data.......................... 4 Dimensions........................................... 24 Wiring Diagrams .................................. 25 Accessories........................................... 28 Standard Features Cabinet Features • • • • • • Heavy-gauge galvanized-steel cabinet with louvered sound control top • Steel louver coil guard • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval • Top and side maintenance access • Single-panel access to controls with space provided for field-installed accessories Energy-efficient compressor Single-speed ECM condenser fan motor Factory-installed filter drier Copper tube/aluminum fin coil Service valves with sweat connections and easy-access gauge ports • Contactor with lug connection • Ground lug connection • AHRI Certified; ETL Listed * Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the 2-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-ANX13 www.amana-hac.com Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. 2/20 Supersedes 12/19 . Nomenclature A N X 13 036 1 AA 1 2 3 4,5 6,7,8 9 10,11 Brand A Engineering * Amana® Brand Major/ Minor Revisions * Not used for order or inventory control. Product Category S Electrical Split System N Nominal Split System 1 - 208/230 V, 1 Phase, 60 Hz Unit Type Nominal Capacity X Condenser R-410A 018 1½ Tons 042 3½ Tons Z Heat Pump R-410A 024 2 Tons 048 4 Tons 030 2½ Tons 060 5 Tons 036 3 Tons 061 5 Tons (high capacity) Efficiency 2 13 13 SEER 16 16 SEER 14 14 SEER 18 18 SEER www.amana-hac.com SS-ANX13 Product Specifications ANX13 0181A* ANX13 0181B* ANX13 0241A* ANX13 0241B* ANX13 0301A* ANX13 0301B* ANX13 0361A* ANX13 0421A* ANX13 0481A* ANX13 0601A* ANX13 0611A* Nominal Cooling (BTU/h) 17,800 17,800 23,000 23,000 28,400 28,400 33,600 40,000 46,000 57,000 56,500 SEER / EER 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 13 / 11 75 72 71 75 73 74 74 75 76 77 77 Capacities Decibels Compressor RLA 9.0 6.0 13.5 7.7 12.8 10.5 14.1 17.9 19.9 25 26.4 LRA 48 37.5 58.3 37 64 47 77 112 109 134 134 Horsepower 1/8 1/8 1/8 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4 FLA 0.7 0.7 0.7 0.65 0.65 0.7 1.2 1.2 1.2 1.2 1.3 Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Line Size (“O.D.) ¾" ¾" ¾" ¾" ¾" ¾" ⅞" 1⅛" 1⅛" 1⅛" 1⅛" Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction Valve Size (“O.D.) ⁴ ⁵ ¾" ¾" ¾" ¾" ¾" ¾" ¾" ³ ⅞" ⁴ ⅞" ⁴ ⅞" ⁴ ⅞" 4 Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Condenser Fan Motor Refrigeration System Refrigerant Line Size ¹ Refrigerant Connection Size Valve Type Refrigerant Charge Shipped with Orifice Size 69 63 63 60 60 68 62 80 91 94 111 0.051 0.052 0.057 0.055 0.065 0.067 0.071 0.074 0.078 0.088 0.086 Electrical Data Voltage/ Phase (60 Hz) Minimum Circuit Ampacity ² 208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1 208/230-60 208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1 208-230/ 1 12 8.2 17.8 10.3 16.7 13.8 18.8 23.6 26.1 32.5 34.3 Max. Overcurrent Protection ³ 20 amps 15 amps 30 amps 15 amps 25 amps 20 30 amps 40 amps 45 amps 50 amps 60 amps Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" 145 141 145 120 134 153 157 206 225 209 231 Ship Weight (lbs) ¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with AHRI Standard 210/240. For other line-set lengths or sizes, refer to the installation and Operating instructions and/or the long line-set guidelines. ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. ⁴ Installer will need to supply ¾” to ⅞” adapters for suction line connections. ⁵ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. Notes • Always check the S&R plate for electrical data on the unit being installed. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • This product may not be installed in the Southeast (including Hawaii) or Southwest Regions as of Jan. 1, 2015. SS-ANX13 www.amana-hac.com 3 4 www.amana-hac.com 675 600 525 675 600 525 16.1 0.77 22 1.27 4.7 216 103 17.4 0.79 21 1.30 4.9 222 106 17.9 0.83 20 1.31 4.9 225 107 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 59 15.8 0.67 19 1.26 4.7 214 101 17.1 0.70 18 1.29 4.8 220 105 17.6 0.73 18 1.30 4.9 222 106 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR Airflow 63 16.5 0.68 20 1.30 4.9 232 109 17.9 0.71 20 1.33 5.0 239 112 18.5 0.74 19 1.34 5.0 242 114 16.4 0.56 16 1.29 4.8 230 108 17.7 0.58 16 1.32 4.9 237 111 18.3 0.61 15 1.33 5.0 239 112 67 17.9 0.52 16 1.33 5.0 245 119 19.4 0.54 16 1.36 5.1 253 123 20.0 0.56 15 1.38 5.2 255 124 17.9 0.39 12 1.33 5.0 243 118 19.4 0.40 12 1.35 5.1 250 122 20.0 0.42 12 1.36 5.1 253 123 19.2 0.33 11 1.37 5.2 256 127 20.8 0.35 11 1.41 5.3 264 131 21.5 0.36 11 1.42 5.4 266 132 - 71 15.7 0.79 22 1.36 5.1 242 108 17.0 0.82 21 1.39 5.3 250 112 17.5 0.86 21 1.40 5.3 252 113 59 15.4 0.70 19 1.35 5.1 240 107 16.7 0.72 19 1.38 5.2 247 111 17.2 0.76 18 1.39 5.3 249 112 63 16.2 0.71 20 1.39 5.2 260 115 17.5 0.74 20 1.42 5.4 269 119 18.0 0.77 19 1.43 5.4 271 120 16.0 0.58 16 1.38 5.2 258 114 17.3 0.60 16 1.41 5.3 266 118 17.9 0.63 15 1.42 5.4 268 119 67 17.5 0.54 16 1.43 5.4 275 126 19.0 0.56 16 1.46 5.5 284 130 19.5 0.58 16 1.47 5.6 286 131 17.5 0.40 12 1.42 5.4 272 125 19.0 0.42 12 1.45 5.5 281 128 19.6 0.44 12 1.46 5.5 283 130 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 18.8 0.35 11 1.47 5.6 287 134 20.3 0.36 11 1.51 5.7 296 138 21.0 0.38 11 1.52 5.8 299 139 - 71 63 15.8 0.73 20 1.47 5.7 296 120 17.1 0.75 20 1.50 5.8 305 123 17.6 0.79 19 1.51 5.9 308 125 15.6 0.60 16 1.46 5.6 293 119 16.9 0.62 16 1.49 5.8 302 122 17.4 0.65 15 1.50 5.8 305 123 67 17.1 0.55 16 1.51 5.9 313 131 18.5 0.57 16 1.55 6.0 322 135 19.1 0.60 16 1.56 6.1 326 136 17.1 0.41 12 1.50 5.8 310 129 18.5 0.43 12 1.54 6.0 319 133 19.1 0.45 12 1.55 6.0 322 135 18.3 0.35 11 1.56 6.1 326 139 19.9 0.37 11 1.60 6.2 336 144 20.5 0.39 11 1.61 6.3 340 145 - 71 59 15.0 0.84 22 1.51 5.9 314 118 16.2 0.87 22 1.54 6.1 323 122 16.7 0.91 21 1.56 6.1 326 123 14.7 0.74 19 1.50 5.9 310 117 15.9 0.77 19 1.53 6.0 320 121 16.4 0.80 18 1.54 6.1 323 122 Shaded area reflects ACCA (TVA) conditions 15.3 0.81 22 1.44 5.5 275 113 16.6 0.84 21 1.47 5.7 284 116 17.1 0.88 21 1.48 5.7 287 117 59 15.1 0.72 19 1.43 5.5 272 111 16.3 0.74 19 1.46 5.6 281 115 16.8 0.78 18 1.47 5.7 284 116 63 15.4 0.75 20 1.54 6.1 337 126 16.7 0.78 20 1.58 6.2 348 130 17.2 0.82 19 1.59 6.3 351 131 15.2 0.62 16 1.53 6.0 334 125 16.5 0.64 16 1.56 6.2 344 128 17.0 0.67 16 1.58 6.2 348 130 67 16.7 0.57 17 1.59 6.2 356 137 18.1 0.59 16 1.62 6.4 367 142 18.6 0.62 16 1.64 6.5 371 143 16.7 0.43 12 1.57 6.2 353 136 18.1 0.44 12 1.61 6.4 364 140 18.6 0.46 12 1.62 6.4 367 142 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 17.9 0.37 11 1.63 6.5 372 146 19.4 0.38 11 1.67 6.7 383 151 20.0 0.40 11 1.69 6.7 387 152 - 71 14.2 0.87 22 1.57 6.3 353 124 15.4 0.90 21 1.60 6.5 364 128 15.9 0.95 20 1.62 6.5 367 129 59 14.0 0.77 19 1.55 6.2 349 123 15.1 0.80 18 1.59 6.4 360 126 15.6 0.83 18 1.60 6.5 364 128 14.6 0.78 20 1.60 6.4 380 132 15.8 0.81 20 1.64 6.6 391 136 16.3 0.85 19 1.65 6.7 395 137 63 14.5 0.64 16 1.59 6.4 376 130 15.7 0.66 16 1.62 6.6 387 135 16.2 0.70 15 1.64 6.6 391 136 15.8 0.59 16 1.65 6.6 401 144 17.2 0.61 16 1.69 6.8 413 148 17.7 0.64 15 1.70 6.9 417 150 67 15.9 0.44 12 1.64 6.6 397 142 17.2 0.46 12 1.67 6.8 409 147 17.7 0.48 12 1.69 6.8 413 148 105ºF 13.2 0.88 20 1.62 6.6 390 128 14.3 0.91 20 1.66 6.8 402 132 14.7 0.96 19 1.67 6.9 406 133 59 12.9 0.77 18 1.60 6.6 386 127 14.0 0.80 17 1.64 6.8 398 131 14.4 0.84 17 1.66 6.8 402 132 13.5 0.79 19 1.65 6.8 419 136 14.7 0.82 18 1.69 7.0 432 141 15.1 0.85 18 1.70 7.1 437 142 63 13.4 0.65 15 1.64 6.7 415 135 14.5 0.67 15 1.68 6.9 428 139 15.0 0.70 14 1.69 7.0 432 141 14.7 0.59 15 1.70 7.0 443 149 15.9 0.62 15 1.74 7.2 457 153 16.4 0.65 14 1.76 7.3 461 155 67 14.7 0.45 12 1.69 7.0 438 147 15.9 0.46 11 1.73 7.2 452 152 16.4 0.49 11 1.74 7.2 456 153 15.7 0.38 11 1.76 7.3 462 159 17.1 0.40 10 1.80 7.5 476 163 17.6 0.42 10 1.81 7.6 481 165 - 71 kW = Total system power Amps = outdoor unit amps (comp.+fan) 17.0 0.38 11 1.70 6.9 418 153 18.4 0.39 11 1.74 7.1 431 158 19.0 0.41 11 1.75 7.1 435 160 - 71 115ºF Expanded Cooling Data — ANX130181A* / CA*F1824*D6*+EEP SS-ANX13 SS-ANX13 www.amana-hac.com 675 600 525 675 600 525 16.6 0.88 26 1.29 4.8 220 105 18.0 0.91 25 1.32 5.0 227 108 18.6 0.96 24 1.33 5.0 229 109 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 59 16.4 0.84 24 1.28 4.8 218 104 17.7 0.87 24 1.31 4.9 225 107 18.3 0.91 23 1.32 5.0 227 108 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR Airflow 63 17.0 0.85 25 1.32 4.9 237 111 18.4 0.88 25 1.35 5.1 244 115 18.9 0.92 24 1.36 5.1 247 116 16.7 0.79 23 1.31 4.9 234 110 18.1 0.82 23 1.34 5.0 242 114 18.7 0.86 22 1.35 5.1 244 115 67 17.8 0.77 24 1.35 5.1 250 121 19.3 0.79 23 1.39 5.2 258 125 19.8 0.83 23 1.40 5.3 260 126 17.9 0.64 20 1.34 5.0 248 120 19.4 0.66 20 1.38 5.2 255 124 19.9 0.70 19 1.39 5.2 258 125 19.0 0.62 21 1.39 5.3 261 129 20.5 0.64 20 1.43 5.4 269 133 21.2 0.68 19 1.44 5.5 272 135 71 19.1 0.5 16 1.4 5.2 258.2 128.1 20.7 0.5 16 1.4 5.4 266.2 132.0 21.3 0.5 15 1.4 5.4 268.9 133.4 16.3 0.91 26 1.38 5.2 247 110 17.6 0.95 26 1.41 5.3 255 114 18.1 0.99 25 1.42 5.4 257 115 59 16.0 0.87 24 1.37 5.2 244 109 17.3 0.90 24 1.40 5.3 252 113 17.8 0.95 23 1.41 5.3 255 114 63 16.6 0.88 26 1.41 5.3 266 118 18.0 0.91 25 1.44 5.5 274 121 18.5 0.96 24 1.45 5.5 277 122 16.3 0.82 23 1.40 5.3 263 116 17.7 0.85 23 1.43 5.4 271 120 18.2 0.89 22 1.44 5.5 274 121 67 17.4 0.79 24 1.45 5.5 281 128 18.8 0.82 24 1.48 5.6 289 132 19.4 0.86 23 1.50 5.7 292 134 17.4 0.66 20 1.44 5.4 278 127 18.9 0.69 20 1.47 5.6 286 131 19.5 0.72 19 1.48 5.6 289 132 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 18.5 0.64 21 1.49 5.7 293 137 20.1 0.67 21 1.53 5.9 302 141 20.7 0.70 20 1.54 5.9 305 142 71 18.6 0.50 16 1.48 5.6 290 135 20.2 0.51 16 1.52 5.8 299 140 20.8 0.54 15 1.53 5.9 302 141 63 16.2 0.90 26 1.49 5.8 302 122 17.5 0.94 25 1.53 5.9 312 126 18.1 0.98 24 1.54 6.0 315 127 15.9 0.84 23 1.48 5.7 299 121 17.3 0.87 23 1.51 5.9 308 125 17.8 0.91 22 1.53 5.9 312 126 67 16.9 0.81 24 1.54 6.0 319 133 18.4 0.84 24 1.57 6.1 329 137 18.9 0.89 23 1.58 6.2 332 139 17.0 0.68 20 1.52 5.9 316 132 18.5 0.71 20 1.56 6.1 326 136 19.0 0.74 19 1.57 6.1 329 137 71 18.1 0.66 21 1.58 6.2 333 142 19.6 0.69 21 1.62 6.4 343 146 20.2 0.72 20 1.63 6.4 347 148 18.2 0.5 16 1.6 6.1 329.6 140.6 19.7 0.5 16 1.6 6.3 339.7 145.0 20.3 0.6 15 1.6 6.4 343.1 146.4 Shaded area reflects AHRI conditions 15.9 0.94 26 1.46 5.6 281 115 17.2 0.97 26 1.50 5.8 290 118 17.7 1.00 24 1.51 5.8 292 120 59 15.6 0.89 24 1.45 5.6 278 114 16.9 0.93 24 1.48 5.7 287 117 17.4 0.97 23 1.50 5.8 290 118 59 15.5 0.97 26 1.53 6.0 320 121 16.8 1.00 26 1.57 6.2 330 124 17.3 1.00 24 1.58 6.2 333 126 15.2 0.92 25 1.52 6.0 317 119 16.5 0.96 24 1.56 6.1 326 123 17.0 1.00 23 1.57 6.2 330 124 63 15.8 0.93 26 1.56 6.2 344 128 17.1 0.97 25 1.60 6.3 355 132 17.6 1.00 24 1.61 6.4 358 134 15.6 0.86 24 1.55 6.1 341 127 16.8 0.90 23 1.59 6.3 351 131 17.4 0.94 22 1.60 6.3 355 132 67 16.5 0.84 24 1.61 6.4 363 140 17.9 0.87 24 1.65 6.5 375 144 18.4 0.91 23 1.66 6.6 378 146 16.6 0.70 20 1.60 6.3 360 139 18.0 0.73 20 1.64 6.5 371 143 18.5 0.76 19 1.65 6.5 375 144 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 17.6 0.68 21 1.66 6.6 379 149 19.1 0.71 21 1.70 6.8 391 154 19.7 0.74 20 1.71 6.8 395 155 71 17.8 0.53 16 1.65 6.5 375 148 19.2 0.54 16 1.69 6.7 387 152 19.8 0.57 15 1.70 6.8 391 154 14.7 1.00 26 1.59 6.4 360 126 15.9 1.00 24 1.63 6.6 371 130 16.4 1.00 22 1.64 6.6 375 132 59 14.5 0.96 24 1.58 6.3 356 125 15.7 0.99 24 1.62 6.5 367 129 16.1 1.00 22 1.63 6.6 371 130 15.0 0.97 25 1.62 6.6 387 134 16.2 1.00 25 1.66 6.7 399 139 16.7 1.00 23 1.68 6.8 403 140 63 14.8 0.90 23 1.61 6.5 383 133 16.0 0.93 23 1.65 6.7 395 137 16.5 1.00 22 1.66 6.7 399 139 15.7 0.87 24 1.67 6.8 409 147 17.0 0.90 24 1.71 7.0 422 151 17.5 0.95 23 1.73 7.0 426 153 67 15.8 0.73 20 1.66 6.7 405 145 17.1 0.76 20 1.70 6.9 417 150 17.6 0.79 19 1.71 7.0 422 151 105ºF 13.6 1.00 24 1.64 6.8 398 131 14.8 1.00 23 1.68 7.0 410 135 15.2 1.00 21 1.70 7.0 414 136 59 13.4 0.96 23 1.63 6.7 394 129 14.5 1.00 22 1.67 6.9 406 133 14.9 1.00 20 1.68 7.0 410 135 13.9 0.97 24 1.68 6.9 428 139 15.0 1.00 23 1.72 7.1 441 143 15.5 1.00 21 1.73 7.2 445 145 63 13.7 0.90 22 1.66 6.9 424 138 14.8 0.94 21 1.70 7.1 437 142 15.3 1.00 21 1.72 7.1 441 143 14.5 0.88 22 1.73 7.2 452 152 15.8 0.91 22 1.77 7.4 466 157 16.2 0.96 21 1.79 7.4 470 158 67 14.6 0.74 19 1.72 7.1 447 150 15.8 0.76 19 1.76 7.3 461 155 16.3 0.80 18 1.77 7.4 466 157 15.5 0.71 19 1.78 7.4 471 162 16.8 0.74 19 1.83 7.6 486 167 17.3 0.78 18 1.84 7.7 491 168 71 15.6 0.55 15 1.77 7.4 467 160 16.9 0.57 15 1.81 7.6 481 165 17.4 0.60 14 1.83 7.6 486 167 kW = Total system power Amps = outdoor unit amps (comp.+fan) 16.8 0.71 21 1.73 7.0 426 156 18.2 0.73 20 1.77 7.2 440 161 18.7 0.77 20 1.78 7.3 444 163 71 16.9 0.5 16 1.7 7.0 422.3 154.8 18.3 0.6 16 1.8 7.2 435.3 159.6 18.8 0.6 15 1.8 7.2 439.7 161.2 115ºF Expanded Cooling Data — ANX130181A* / CA*F1824*D6*+EEP (cont.) 5 6 www.amana-hac.com 650 600 525 650 600 525 16.4 0.74 21 1.02 4.1 226 112 17.2 0.76 20 1.03 4.1 229 113 17.7 0.77 19 1.04 4.2 233 115 15.9 0.83 23 0.99 4.0 210 105 16.7 0.84 22 1.00 4.0 213 106 17.2 0.86 21 1.02 4.1 216 108 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 63 16.2 0.61 17 1.01 4.0 224 111 17.0 0.62 16 1.02 4.1 227 112 17.6 0.63 16 1.03 4.2 231 114 59 15.6 0.73 20 0.98 3.9 208 104 16.4 0.74 19 1.00 4.0 211 105 16.9 0.76 18 1.01 4.0 214 107 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR Airflow 67 17.7 0.56 18 1.05 4.2 239 122 18.6 0.57 16 1.06 4.3 242 124 19.2 0.58 16 1.08 4.3 246 126 17.7 0.42 13 1.04 4.2 236 121 18.7 0.43 12 1.05 4.2 239 122 19.2 0.44 12 1.07 4.3 243 124 19.0 0.36 12 1.09 4.4 249 130 20.0 0.37 11 1.10 4.4 252 132 20.6 0.38 11 1.12 4.5 257 134 - 71 15.5 0.86 23 1.08 4.3 236 111 16.3 0.88 22 1.09 4.4 239 112 16.8 0.89 21 1.11 4.5 243 114 59 15.3 0.76 20 1.07 4.3 233 110 16.0 0.77 19 1.08 4.3 236 111 16.5 0.79 18 1.10 4.4 240 113 63 16.0 0.77 22 1.10 4.4 253 118 16.8 0.78 20 1.12 4.5 257 120 17.3 0.80 20 1.13 4.6 261 122 15.8 0.63 18 1.09 4.4 251 117 16.6 0.64 16 1.11 4.4 254 118 17.1 0.66 16 1.12 4.5 259 120 67 17.3 0.58 18 1.14 4.6 268 129 18.2 0.59 17 1.16 4.7 271 131 18.7 0.61 16 1.17 4.7 276 133 17.3 0.44 13 1.13 4.5 265 127 18.2 0.45 12 1.15 4.6 269 129 18.8 0.45 12 1.16 4.7 273 131 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 18.6 0.38 12 1.18 4.8 279 137 19.5 0.38 11 1.20 4.8 283 139 20.1 0.39 11 1.22 4.9 288 141 - 71 63 15.6 0.79 22 1.18 4.9 288 123 16.4 0.80 20 1.20 4.9 292 124 16.9 0.82 20 1.21 5.0 297 126 15.4 0.65 18 1.17 4.8 285 121 16.2 0.66 16 1.18 4.9 289 123 16.7 0.67 16 1.20 5.0 294 125 67 16.9 0.60 18 1.22 5.0 304 134 17.8 0.61 17 1.24 5.1 309 136 18.3 0.62 16 1.26 5.2 314 138 16.9 0.45 13 1.21 5.0 301 133 17.8 0.46 13 1.23 5.0 305 134 18.3 0.47 12 1.25 5.1 311 137 18.1 0.38 12 1.27 5.2 318 143 19.1 0.39 11 1.28 5.3 322 144 19.6 0.40 11 1.30 5.4 327 147 - 71 59 14.8 0.91 24 1.22 5.1 305 121 15.5 0.93 22 1.23 5.2 309 123 16.0 0.95 21 1.25 5.2 315 125 14.5 0.80 20 1.21 5.0 302 120 15.3 0.82 19 1.22 5.1 306 121 15.8 0.83 19 1.24 5.2 311 124 Shaded area reflects ACCA (TVA) conditions 15.2 0.88 24 1.15 4.7 268 115 15.9 0.90 22 1.17 4.8 271 117 16.4 0.92 21 1.19 4.9 276 119 59 14.9 0.78 20 1.14 4.7 265 114 15.7 0.79 19 1.16 4.7 269 116 16.1 0.81 18 1.17 4.8 273 118 16.5 0.62 18 1.29 5.4 347 141 17.3 0.63 17 1.31 5.5 351 142 17.9 0.64 16 1.33 5.6 357 145 15.2 0.82 22 1.25 5.2 328 129 16.0 0.83 20 1.26 5.3 333 131 16.5 0.85 20 1.28 5.4 339 133 67 16.5 0.46 13 1.28 5.4 343 139 17.4 0.47 13 1.30 5.4 348 141 17.9 0.48 12 1.32 5.5 354 143 63 15.1 0.67 18 1.24 5.2 325 127 15.8 0.68 17 1.25 5.2 329 129 16.3 0.70 16 1.27 5.3 335 131 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 17.7 0.40 12 1.34 5.6 362 150 18.6 0.40 12 1.36 5.7 366 152 19.2 0.41 11 1.38 5.8 373 154 - 71 14.0 0.95 23 1.28 5.4 343 127 14.8 0.96 22 1.29 5.5 348 129 15.2 0.98 21 1.31 5.6 354 131 59 13.8 0.83 20 1.26 5.4 340 126 14.5 0.85 19 1.28 5.5 344 127 15.0 0.86 18 1.30 5.5 350 129 14.5 0.85 21 1.31 5.6 369 135 15.2 0.86 20 1.32 5.7 374 137 15.7 0.88 20 1.34 5.8 381 139 63 14.3 0.70 17 1.30 5.5 366 134 15.0 0.71 16 1.31 5.6 371 135 15.5 0.72 16 1.33 5.7 377 138 15.7 0.64 18 1.35 5.8 390 147 16.5 0.65 16 1.37 5.9 395 149 17.0 0.66 16 1.39 6.0 402 152 67 15.7 0.48 13 1.34 5.7 386 146 16.5 0.49 12 1.36 5.8 391 148 17.0 0.50 12 1.38 5.9 398 150 105ºF 13.0 0.95 22 1.32 5.8 379 131 13.7 0.97 20 1.34 5.9 384 133 14.1 0.99 20 1.36 6.0 391 135 59 12.8 0.84 19 1.31 5.7 375 130 13.4 0.85 18 1.33 5.8 380 132 13.9 0.87 17 1.35 5.9 387 134 13.4 0.85 20 1.36 5.9 408 140 14.1 0.87 19 1.37 6.0 414 141 14.5 0.89 18 1.40 6.1 421 144 63 13.3 0.70 16 1.34 5.9 404 138 13.9 0.71 15 1.36 6.0 409 140 14.4 0.73 15 1.38 6.1 417 142 14.5 0.65 16 1.41 6.2 431 152 15.2 0.66 15 1.42 6.2 437 154 15.7 0.67 15 1.45 6.3 444 157 67 14.5 0.49 12 1.39 6.1 427 151 15.3 0.49 12 1.41 6.2 432 153 15.7 0.50 11 1.43 6.3 440 156 15.6 0.42 11 1.46 6.4 450 162 16.4 0.42 11 1.48 6.5 456 164 16.9 0.43 10 1.50 6.6 463 167 - 71 kW = Total system power Amps = outdoor unit amps (comp.+fan) 16.8 0.41 12 1.40 6.0 407 157 17.7 0.42 11 1.42 6.1 412 159 18.2 0.43 11 1.44 6.2 419 162 - 71 115ºF Expanded Cooling Data — ANX130181B* / CA*F1824*D6*+EEP SS-ANX13 SS-ANX13 www.amana-hac.com 650 600 525 650 600 525 16.8 0.92 27 1.03 4.2 230 114 17.6 0.94 25 1.05 4.2 234 115 18.2 0.96 25 1.06 4.3 238 117 16.5 0.96 28 1.01 4.0 214 107 17.3 0.97 26 1.02 4.1 217 109 17.8 0.99 25 1.04 4.2 221 110 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 63 16.5 0.86 25 1.02 4.1 228 113 17.4 0.87 23 1.04 4.2 231 114 17.9 0.89 23 1.05 4.2 235 116 59 16.2 0.91 26 1.00 4.0 212 106 17.0 0.93 24 1.01 4.1 215 107 17.5 0.95 24 1.03 4.1 219 109 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR Airflow 67 17.6 0.83 26 1.07 4.3 243 124 18.5 0.85 24 1.08 4.4 247 126 19.0 0.86 23 1.10 4.4 251 128 17.7 0.70 22 1.06 4.3 241 123 18.6 0.71 20 1.07 4.3 244 125 19.1 0.72 20 1.09 4.4 248 127 18.7 0.68 22 1.11 4.5 254 132 19.7 0.69 21 1.12 4.5 257 134 20.3 0.70 20 1.14 4.6 262 137 71 18.9 0.5 17 1.1 4.4 251.0 131.0 19.8 0.5 16 1.1 4.5 255.0 133.0 20.5 0.5 16 1.1 4.6 259.0 135.0 16.1 0.99 28 1.10 4.4 240 113 16.9 1.00 26 1.11 4.5 244 115 17.4 1.00 25 1.13 4.5 248 117 59 15.8 0.95 26 1.09 4.4 238 112 16.6 0.96 24 1.10 4.4 241 114 17.1 1.00 24 1.12 4.5 245 115 63 16.4 0.96 27 1.12 4.5 259 120 17.2 0.97 26 1.14 4.6 262 122 17.8 0.99 25 1.15 4.7 267 124 16.1 0.89 25 1.11 4.5 256 119 17.0 0.90 23 1.13 4.5 259 121 17.5 0.92 23 1.14 4.6 264 123 67 17.2 0.86 26 1.16 4.7 273 131 18.0 0.88 24 1.18 4.7 277 133 18.6 0.89 24 1.20 4.8 282 135 17.3 0.72 22 1.15 4.6 270 130 18.1 0.73 20 1.17 4.7 274 132 18.7 0.75 20 1.19 4.8 279 134 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 18.3 0.70 23 1.21 4.9 285 140 19.2 0.71 21 1.22 4.9 289 142 19.8 0.73 20 1.24 5.0 294 144 71 18.4 0.54 17 1.19 4.8 282 139 19.4 0.55 16 1.21 4.9 286 140 20.0 0.56 16 1.23 5.0 291 143 63 16.0 0.98 28 1.20 5.0 294 125 16.8 1.00 26 1.22 5.0 298 127 17.3 1.00 25 1.24 5.1 303 129 15.8 0.91 25 1.19 4.9 291 124 16.6 0.92 23 1.21 5.0 295 126 17.1 0.94 23 1.23 5.1 300 128 67 16.8 0.88 26 1.25 5.1 311 137 17.6 0.90 24 1.26 5.2 315 138 18.2 0.92 24 1.28 5.3 320 141 16.8 0.74 22 1.23 5.1 308 135 17.7 0.75 20 1.25 5.1 312 137 18.2 0.77 20 1.27 5.2 317 139 71 17.9 0.72 23 1.29 5.3 324 145 18.8 0.73 21 1.31 5.4 328 147 19.4 0.74 20 1.33 5.5 334 150 18.0 0.6 17 1.3 5.3 321.0 144.0 18.9 0.6 16 1.3 5.4 325.0 146.0 19.5 0.6 16 1.3 5.5 331.0 148.0 Shaded area reflects AHRI conditions 15.7 1.00 28 1.17 4.8 273 118 16.5 1.00 25 1.19 4.9 277 119 17.0 1.00 24 1.21 5.0 282 121 59 15.4 0.97 26 1.16 4.8 271 116 16.2 0.98 25 1.18 4.8 274 118 16.7 1.00 24 1.20 4.9 279 120 59 15.3 1.00 27 1.24 5.2 311 124 16.1 1.00 25 1.26 5.3 315 125 16.6 1.00 24 1.28 5.3 321 127 15.0 1.00 26 1.23 5.1 308 122 15.8 1.00 24 1.25 5.2 312 124 16.3 1.00 23 1.27 5.3 318 126 63 15.6 1.00 27 1.27 5.3 335 131 16.4 1.00 25 1.29 5.4 339 133 16.9 1.00 24 1.31 5.5 345 135 15.4 0.94 25 1.26 5.3 332 130 16.2 0.95 24 1.28 5.3 336 132 16.7 1.00 24 1.30 5.4 342 134 67 16.3 0.91 26 1.32 5.5 354 143 17.2 0.93 24 1.33 5.6 358 145 17.7 0.95 24 1.36 5.7 365 148 16.4 0.76 22 1.31 5.5 350 142 17.3 0.78 21 1.32 5.5 355 144 17.8 0.79 20 1.34 5.6 361 146 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 17.4 0.74 23 1.37 5.7 369 153 18.3 0.75 21 1.38 5.8 374 155 18.9 0.77 21 1.41 5.9 380 157 71 17.6 0.57 18 1.35 5.7 365 151 18.5 0.58 16 1.37 5.8 370 153 19.0 0.59 16 1.39 5.9 377 156 14.5 1.00 26 1.30 5.5 350 129 15.3 1.00 23 1.32 5.6 355 131 15.8 1.00 22 1.34 5.7 361 133 59 14.3 1.04 26 1.29 5.5 347 128 15.0 1.00 23 1.30 5.6 351 130 15.5 1.00 22 1.32 5.7 357 132 14.8 1.00 26 1.33 5.7 377 138 15.6 1.00 24 1.35 5.8 382 140 16.1 1.00 23 1.37 5.9 389 142 63 14.6 0.97 25 1.32 5.6 373 136 15.4 0.99 23 1.34 5.7 378 138 15.8 1.00 22 1.36 5.8 385 141 15.5 0.95 26 1.38 5.9 398 150 16.3 0.96 24 1.40 6.0 403 152 16.8 0.98 23 1.42 6.1 410 155 67 15.6 0.79 22 1.37 5.8 394 149 16.4 0.81 20 1.38 5.9 399 151 16.9 0.82 20 1.41 6.0 406 153 105ºF 13.5 1.00 24 1.35 5.9 387 134 14.2 1.00 22 1.37 6.0 392 136 14.6 1.00 21 1.39 6.1 399 138 59 13.2 1.05 24 1.34 5.8 383 133 13.9 1.00 21 1.35 5.9 388 134 14.3 1.00 20 1.37 6.0 395 137 13.7 1.00 24 1.38 6.1 416 142 14.4 1.00 22 1.40 6.1 422 144 14.9 1.00 21 1.42 6.2 429 147 63 13.5 0.98 23 1.37 6.0 412 141 14.2 1.00 22 1.39 6.1 418 143 14.7 1.00 21 1.41 6.2 425 145 14.4 0.96 24 1.43 6.3 440 155 15.1 0.97 23 1.45 6.4 446 158 15.6 0.99 22 1.47 6.5 453 160 67 14.5 0.80 20 1.42 6.2 435 154 15.2 0.81 19 1.44 6.3 441 156 15.7 0.83 18 1.46 6.4 449 159 15.3 0.78 21 1.49 6.5 459 166 16.1 0.79 20 1.50 6.6 465 168 16.6 0.80 19 1.53 6.7 473 171 71 15.5 0.60 16 1.47 6.5 454 164 16.2 0.61 15 1.49 6.6 460 166 16.7 0.62 15 1.51 6.7 468 169 kW = Total system power Amps = outdoor unit amps (comp.+fan) 16.6 0.77 22 1.43 6.1 415 160 17.4 0.78 21 1.45 6.2 421 162 18.0 0.80 20 1.47 6.3 428 165 71 16.7 0.6 17 1.4 6.1 411.0 159.0 17.5 0.6 16 1.4 6.2 416.0 161.0 18.1 0.6 16 1.5 6.3 424.0 163.0 115ºF Expanded Cooling Data — ANX130181B* / CA*F1824*D6*+EEP (cont.) 7 8 www.amana-hac.com 900 800 700 900 800 700 20.5 0.78 21 1.62 6.0 225 101 22.3 0.81 21 1.65 6.1 232 104 22.9 0.85 20 1.67 6.2 234 105 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 59 20.2 0.68 18 1.60 5.9 222 100 21.9 0.71 18 1.64 6.1 229 103 22.5 0.74 17 1.65 6.1 231 104 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR Airflow 63 21.1 0.70 19 1.65 6.1 242 108 22.9 0.72 19 1.69 6.3 249 111 23.6 0.76 18 1.70 6.3 252 112 20.9 0.57 16 1.64 6.0 239 106 22.7 0.59 15 1.67 6.2 247 110 23.4 0.62 15 1.69 6.3 249 111 67 22.9 0.53 16 1.70 6.3 255 117 24.8 0.55 16 1.74 6.5 263 121 25.5 0.57 15 1.75 6.5 266 122 22.9 0.40 12 1.68 6.2 253 116 24.8 0.41 12 1.72 6.4 260 120 25.6 0.43 11 1.74 6.5 263 121 24.6 0.34 11 1.75 6.5 266 125 26.6 0.35 11 1.79 6.7 274 129 27.4 0.37 10 1.80 6.8 277 130 - 71 20.1 0.81 21 1.73 6.4 252 107 21.7 0.84 21 1.77 6.6 260 110 22.4 0.88 20 1.79 6.7 262 111 59 19.7 0.71 18 1.72 6.4 249 106 21.4 0.74 18 1.76 6.6 257 109 22.0 0.77 17 1.77 6.6 260 110 63 20.7 0.72 20 1.77 6.6 271 114 22.4 0.75 19 1.81 6.8 280 117 23.0 0.78 18 1.82 6.8 282 118 20.4 0.59 16 1.75 6.5 268 112 22.2 0.61 16 1.79 6.7 277 116 22.8 0.64 15 1.81 6.8 280 117 67 22.4 0.55 16 1.82 6.8 286 124 24.2 0.57 16 1.86 7.0 295 128 24.9 0.59 15 1.88 7.1 298 129 22.4 0.41 12 1.81 6.7 283 123 24.3 0.43 12 1.85 6.9 292 127 25.0 0.45 11 1.86 7.0 295 128 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 24.0 0.35 11 1.88 7.1 299 132 26.0 0.36 11 1.92 7.3 308 136 26.8 0.38 10 1.94 7.3 311 138 - 71 63 20.2 0.74 20 1.87 7.2 308 118 21.8 0.77 19 1.92 7.4 318 122 22.5 0.80 18 1.93 7.4 321 123 20.0 0.61 16 1.86 7.1 305 117 21.6 0.63 16 1.90 7.3 315 120 22.3 0.66 15 1.92 7.4 318 122 67 21.8 0.56 16 1.93 7.4 326 129 23.6 0.58 16 1.98 7.6 336 133 24.4 0.61 15 1.99 7.7 339 134 21.9 0.42 12 1.91 7.3 322 128 23.7 0.44 12 1.96 7.5 332 132 24.4 0.46 11 1.97 7.6 336 133 23.4 0.36 11 1.99 7.7 340 137 25.4 0.37 11 2.04 7.9 350 142 26.1 0.39 10 2.05 8.0 354 143 - 71 59 19.1 0.85 21 1.92 7.5 326 117 20.7 0.89 21 1.97 7.7 337 120 21.3 0.93 20 1.99 7.8 340 121 18.8 0.75 19 1.91 7.4 323 115 20.4 0.78 18 1.95 7.6 333 119 21.0 0.82 17 1.97 7.7 336 120 Shaded area reflects ACCA (TVA) conditions 19.6 0.83 21 1.83 7.0 287 111 21.2 0.86 21 1.88 7.2 295 114 21.9 0.90 20 1.89 7.3 298 116 59 19.3 0.73 18 1.82 6.9 284 110 20.9 0.75 18 1.86 7.1 293 113 21.5 0.79 17 1.88 7.2 295 114 63 19.7 0.76 20 1.96 7.7 351 124 21.3 0.79 19 2.01 7.9 362 128 22.0 0.83 19 2.03 8.0 366 129 19.5 0.63 16 1.95 7.6 348 123 21.1 0.65 16 2.00 7.8 359 127 21.7 0.68 15 2.01 7.9 362 128 67 21.3 0.58 16 2.02 7.9 371 135 23.1 0.60 16 2.07 8.2 382 140 23.8 0.63 15 2.09 8.2 386 141 21.3 0.43 12 2.01 7.8 367 134 23.1 0.45 12 2.06 8.1 379 138 23.8 0.47 11 2.07 8.2 382 140 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 22.9 0.37 11 2.09 8.2 387 144 24.8 0.39 11 2.14 8.5 399 149 25.5 0.40 11 2.16 8.5 403 150 - 71 18.2 0.89 21 2.00 8.0 367 122 19.7 0.92 21 2.05 8.2 379 126 20.3 0.96 20 2.07 8.3 382 127 59 17.8 0.78 18 1.98 7.9 364 121 19.3 0.81 18 2.03 8.1 375 125 19.9 0.85 17 2.05 8.2 379 126 18.7 0.79 19 2.04 8.2 395 130 20.2 0.82 19 2.09 8.4 407 134 20.9 0.86 18 2.11 8.5 412 135 63 18.5 0.65 16 2.03 8.1 391 129 20.0 0.67 16 2.08 8.3 403 133 20.6 0.71 15 2.09 8.4 407 134 20.2 0.60 16 2.11 8.4 417 142 21.9 0.62 16 2.16 8.7 430 146 22.6 0.65 15 2.18 8.8 435 148 67 20.3 0.45 12 2.09 8.4 413 140 22.0 0.47 12 2.14 8.6 426 145 22.6 0.49 11 2.16 8.7 430 146 105ºF 16.8 0.89 20 2.07 8.4 406 126 18.2 0.93 19 2.12 8.7 418 130 18.8 0.97 19 2.13 8.8 423 132 59 16.5 0.79 17 2.05 8.4 402 125 17.9 0.81 17 2.10 8.6 414 129 18.4 0.85 16 2.12 8.7 418 130 17.3 0.80 18 2.11 8.7 437 134 18.8 0.83 18 2.16 8.9 450 139 19.3 0.87 17 2.18 9.0 455 140 63 17.1 0.66 15 2.09 8.6 432 133 18.6 0.68 15 2.14 8.8 446 137 19.1 0.71 14 2.16 8.9 450 139 18.7 0.60 15 2.18 8.9 461 147 20.3 0.63 15 2.23 9.2 475 151 20.9 0.66 14 2.25 9.3 480 153 67 18.8 0.45 11 2.16 8.9 456 145 20.3 0.47 11 2.21 9.1 471 150 21.0 0.49 11 2.23 9.2 475 151 20.1 0.39 10 2.25 9.3 481 156 21.8 0.40 10 2.30 9.6 496 161 22.4 0.42 10 2.32 9.7 501 163 - 71 kW = Total system power Amps = outdoor unit amps (comp.+fan) 21.7 0.39 11 2.17 8.8 435 151 23.5 0.40 11 2.23 9.0 449 156 24.2 0.42 10 2.25 9.1 453 157 - 71 115ºF Expanded Cooling Data — ANX130241A* / CA*F3030*6D*+EEP SS-ANX13 SS-ANX13 www.amana-hac.com 900 800 700 900 800 700 21.3 0.89 25 1.64 6.1 229 103 23.0 0.93 25 1.68 6.2 236 106 23.7 0.97 24 1.69 6.3 239 107 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR 59 20.9 0.85 23 1.63 6.0 227 102 22.6 0.88 23 1.67 6.2 234 105 23.3 0.93 22 1.68 6.2 236 106 MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR MBh S/T ∆T kW Amps HI PR LO PR Airflow 63 21.7 0.86 25 1.67 6.2 247 110 23.5 0.90 24 1.71 6.4 254 113 24.2 0.94 23 1.72 6.4 257 114 21.4 0.80 22 1.66 6.2 244 109 23.1 0.83 22 1.70 6.3 252 112 23.8 0.87 21 1.71 6.4 254 113 67 22.7 0.78 23 1.72 6.4 260 120 24.6 0.81 23 1.76 6.6 268 123 25.3 0.85 22 1.78 6.7 271 125 22.8 0.65 20 1.71 6.4 258 119 24.7 0.68 19 1.75 6.5 266 122 25.5 0.71 18 1.76 6.6 268 123 24.2 0.63 20 1.77 6.7 272 128 26.2 0.66 20 1.82 6.8 280 131 27.0 0.69 19 1.83 6.9 283 133 71 24.4 0.5 16 1.8 6.6 268.9 126.3 26.4 0.5 15 1.8 6.8 277.2 130.2 27.2 0.5 15 1.8 6.8 280.0 131.5 20.8 0.93 25 1.76 6.6 257 109 22.5 0.96 25 1.80 6.7 265 112 23.2 1.00 24 1.81 6.8 268 113 59 20.4 0.88 24 1.74 6.5 255 108 22.1 0.92 23 1.79 6.7 262 111 22.8 0.96 22 1.80 6.7 265 112 63 21.2 0.89 25 1.79 6.7 277 116 22.9 0.93 24 1.84 6.9 285 119 23.6 0.97 23 1.85 7.0 288 121 20.9 0.83 23 1.78 6.7 274 115 22.6 0.86 22 1.82 6.8 282 118 23.3 0.90 21 1.84 6.9 285 119 67 22.2 0.81 24 1.85 6.9 292 127 24.0 0.84 23 1.89 7.1 301 130 24.8 0.88 22 1.91 7.2 304 132 22.3 0.68 20 1.83 6.9 289 125 24.2 0.70 19 1.88 7.1 298 129 24.9 0.73 19 1.89 7.1 301 130 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 23.7 0.65 20 1.90 7.2 305 135 25.6 0.68 20 1.95 7.4 314 139 26.4 0.71 19 1.97 7.5 317 140 71 23.8 0.50 16 1.89 7.1 302 133 25.8 0.52 16 1.94 7.3 311 138 26.6 0.55 15 1.95 7.4 314 139 63 20.7 0.92 25 1.90 7.3 315 120 22.4 0.95 24 1.95 7.5 324 124 23.1 1.00 24 1.96 7.6 328 125 20.4 0.85 23 1.89 7.2 312 119 22.1 0.88 22 1.93 7.4 321 123 22.7 0.92 21 1.95 7.5 324 124 67 21.7 0.83 24 1.96 7.5 332 132 23.5 0.86 23 2.01 7.8 343 136 24.2 0.90 22 2.02 7.8 346 137 21.8 0.69 20 1.94 7.5 329 130 23.6 0.72 19 1.99 7.7 339 134 24.3 0.75 19 2.01 7.8 343 136 71 23.1 0.67 20 2.02 7.8 347 140 25.0 0.70 20 2.07 8.1 357 144 25.8 0.73 19 2.09 8.1 361 146 23.3 0.5 16 2.0 7.8 343.1 138.7 25.2 0.5 16 2.1 8.0 353.8 143.0 26.0 0.6 15 2.1 8.1 357.3 144.4 Shaded area reflects AHRI conditions 20.3 0.95 25 1.86 7.1 292 113 22.0 0.99 25 1.91 7.3 301 117 22.6 1.00 23 1.92 7.4 304 118 59 19.9 0.91 24 1.85 7.1 290 112 21.6 0.94 23 1.89 7.3 298 116 22.2 1.00 23 1.91 7.3 301 117 59 19.8 0.98 25 1.95 7.6 333 119 21.4 1.00 25 2.00 7.8 343 123 22.1 1.00 23 2.02 7.9 347 124 19.4 0.94 24 1.94 7.6 330 118 21.1 0.97 24 1.99 7.8 340 121 21.7 1.00 22 2.00 7.8 343 123 63 20.2 0.95 25 1.99 7.8 358 127 21.9 0.98 25 2.04 8.0 369 130 22.5 1.00 23 2.06 8.1 373 132 19.9 0.88 23 1.98 7.7 355 125 21.5 0.91 23 2.03 8.0 366 129 22.2 0.95 22 2.04 8.0 369 130 67 21.1 0.85 24 2.06 8.1 378 138 22.9 0.89 23 2.11 8.3 390 142 23.6 0.93 22 2.12 8.4 394 144 21.2 0.71 20 2.04 8.0 375 137 23.0 0.74 20 2.09 8.2 386 141 23.7 0.78 19 2.11 8.3 390 142 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 22.5 0.69 21 2.12 8.4 395 147 24.4 0.72 20 2.17 8.6 407 152 25.1 0.75 19 2.19 8.7 411 153 71 22.7 0.53 16 2.11 8.3 391 146 24.6 0.55 16 2.16 8.5 403 150 25.3 0.58 15 2.17 8.6 407 152 18.8 1.00 25 2.03 8.1 375 125 20.4 1.00 23 2.08 8.3 386 129 21.0 1.00 21 2.10 8.4 390 130 59 18.5 0.97 24 2.02 8.0 371 123 20.0 1.00 23 2.07 8.3 382 127 20.6 1.00 21 2.08 8.3 386 129 19.2 0.98 25 2.08 8.3 403 133 20.8 1.00 24 2.13 8.6 416 137 21.4 1.00 22 2.14 8.6 420 138 63 18.9 0.91 23 2.06 8.2 399 131 20.5 0.94 22 2.11 8.5 412 135 21.1 1.00 22 2.13 8.6 416 137 20.1 0.89 23 2.14 8.6 426 145 21.7 0.92 23 2.19 8.8 439 149 22.4 0.96 22 2.21 8.9 443 151 67 20.2 0.74 20 2.12 8.5 422 143 21.9 0.77 19 2.18 8.8 435 148 22.5 0.81 19 2.19 8.8 439 149 105ºF 17.4 1.00 23 2.10 8.6 414 129 18.9 1.00 22 2.15 8.9 427 133 19.4 1.00 20 2.17 8.9 431 134 59 17.1 0.98 22 2.08 8.5 410 128 18.5 1.00 21 2.13 8.8 423 132 19.1 1.00 20 2.15 8.9 427 133 17.7 0.99 23 2.14 8.8 445 137 19.2 1.00 22 2.20 9.1 459 141 19.8 1.00 20 2.22 9.2 464 143 63 17.5 0.92 21 2.13 8.7 441 136 18.9 0.95 21 2.18 9.0 455 140 19.5 1.00 20 2.20 9.1 459 141 18.6 0.89 22 2.21 9.1 470 150 20.1 0.93 21 2.27 9.4 485 154 20.7 0.97 21 2.29 9.5 490 156 67 18.7 0.75 18 2.19 9.0 466 148 20.2 0.78 18 2.25 9.3 480 153 20.8 0.81 17 2.27 9.4 485 154 19.8 0.73 19 2.28 9.5 491 159 21.5 0.75 19 2.34 9.7 506 164 22.1 0.79 18 2.36 9.8 511 166 71 20.0 0.56 15 2.27 9.4 486 158 21.6 0.58 14 2.32 9.7 501 163 22.3 0.61 14 2.34 9.7 506 164 kW = Total system power Amps = outdoor unit amps (comp.+fan) 21.4 0.72 20 2.21 8.9 444 154 23.2 0.75 20 2.26 9.2 458 159 23.9 0.78 19 2.28 9.3 462 161 71 21.6 0.6 16 2.2 8.8 439.7 152.7 23.4 0.6 15 2.2 9.1 453.3 157.4 24.1 0.6 15 2.3 9.2 457.8 158.9 115ºF Expanded Cooling Data — ANX130241A* / CA*F3030*6D*+EEP (cont.) 9 10 www.amana-hac.com 700 800 900 700 800 900 22.9 0.83 19 1.64 5.9 231 106 22.3 0.79 20 1.63 5.8 228 105 20.5 0.76 21 1.59 5.7 222 102 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 59 22.5 0.73 17 1.63 5.8 228 105 21.9 0.70 18 1.62 5.8 226 104 20.2 0.67 18 1.58 5.6 219 101 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR Airflow 63 23.6 0.74 18 1.67 6.0 248 113 22.9 0.71 19 1.66 6.0 246 112 21.1 0.68 19 1.62 5.8 238 108 23.4 0.61 15 1.66 6.0 246 112 22.7 0.58 15 1.65 5.9 243 111 20.9 0.56 15 1.61 5.7 236 107 67 25.5 0.56 15 1.72 6.2 262 123 24.8 0.54 15 1.71 6.2 260 122 22.9 0.52 16 1.67 6.0 252 118 25.6 0.42 11 1.71 6.2 259 122 24.8 0.40 12 1.70 6.1 257 121 22.9 0.39 12 1.66 5.9 249 117 27.4 0.36 10 1.77 6.4 273 131 26.6 0.34 11 1.76 6.4 271 130 24.6 0.33 11 1.72 6.2 263 126 - 71 22.4 0.86 20 1.76 6.3 259 112 21.7 0.82 20 1.75 6.3 256 111 20.1 0.79 21 1.71 6.1 249 108 59 22.0 0.76 17 1.75 6.3 256 111 21.4 0.72 18 1.73 6.2 254 110 19.7 0.70 18 1.69 6.1 246 106 63 23.0 0.77 18 1.79 6.5 279 119 22.4 0.73 19 1.78 6.4 276 118 20.7 0.71 19 1.74 6.3 267 114 22.8 0.63 15 1.78 6.4 276 118 22.2 0.60 15 1.77 6.4 273 117 20.4 0.58 16 1.73 6.2 265 113 67 24.9 0.58 15 1.85 6.7 294 130 24.2 0.56 15 1.84 6.7 291 129 22.4 0.54 16 1.79 6.5 282 125 25.0 0.44 11 1.83 6.7 291 129 24.3 0.42 12 1.82 6.6 288 127 22.4 0.40 12 1.78 6.4 280 124 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 26.8 0.37 10 1.91 7.0 307 139 26.0 0.36 11 1.89 6.9 304 137 24.0 0.34 11 1.85 6.7 295 133 - 71 24.4 0.60 15 1.96 7.3 334 135 23.6 0.57 15 1.95 7.2 331 134 21.8 0.55 16 1.90 7.0 321 130 22.5 0.79 18 1.90 7.1 317 124 21.8 0.75 19 1.89 7.0 314 123 20.2 0.73 19 1.84 6.8 304 119 67 24.4 0.45 11 1.95 7.2 331 134 23.7 0.43 12 1.93 7.2 328 132 21.9 0.41 12 1.89 7.0 318 129 63 22.3 0.65 15 1.89 7.0 314 123 21.6 0.62 15 1.87 6.9 310 121 20.0 0.60 16 1.83 6.7 301 118 26.1 0.38 10 2.02 7.6 349 144 25.4 0.37 11 2.01 7.5 345 143 23.4 0.35 11 1.96 7.3 335 138 - 71 59 21.3 0.91 20 1.96 7.4 335 122 20.7 0.87 21 1.94 7.3 332 121 19.1 0.84 21 1.90 7.1 322 117 21.0 0.80 17 1.94 7.3 332 121 20.4 0.76 18 1.93 7.2 329 120 18.8 0.74 18 1.88 7.0 319 116 Shaded area reflects ACCA (TVA) conditions 21.9 0.88 20 1.86 6.9 294 116 21.2 0.84 21 1.85 6.8 291 115 19.6 0.81 21 1.81 6.6 283 112 59 21.5 0.78 17 1.85 6.8 291 115 20.9 0.74 18 1.84 6.8 288 114 19.3 0.71 18 1.79 6.6 280 111 63 22.0 0.81 18 2.00 7.5 361 130 21.3 0.78 19 1.98 7.5 357 129 19.7 0.75 19 1.94 7.3 346 125 21.7 0.67 15 1.98 7.5 357 129 21.1 0.64 15 1.97 7.4 354 127 19.5 0.62 16 1.92 7.2 343 124 67 23.8 0.62 15 2.06 7.8 381 142 23.1 0.59 16 2.04 7.7 377 141 21.3 0.57 16 2.00 7.5 366 136 23.8 0.46 11 2.04 7.7 377 141 23.1 0.44 12 2.03 7.7 373 139 21.3 0.43 12 1.98 7.4 362 135 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 25.5 0.40 10 2.13 8.1 397 151 24.8 0.38 11 2.11 8.0 393 150 22.9 0.36 11 2.06 7.8 382 145 - 71 20.3 0.95 20 2.04 7.8 377 128 19.7 0.90 20 2.02 7.8 373 127 18.2 0.87 21 1.97 7.6 362 123 59 19.9 0.83 17 2.02 7.8 373 127 19.3 0.79 18 2.00 7.7 370 126 17.8 0.76 18 1.96 7.5 359 122 20.9 0.85 18 2.08 8.0 406 136 20.2 0.81 19 2.06 8.0 402 135 18.7 0.78 19 2.01 7.7 390 131 63 20.6 0.69 15 2.06 8.0 402 135 20.0 0.66 15 2.05 7.9 398 134 18.5 0.64 16 2.00 7.7 386 130 22.6 0.64 15 2.15 8.3 429 149 21.9 0.61 15 2.13 8.2 424 147 20.2 0.59 16 2.08 8.0 412 143 67 22.6 0.48 11 2.13 8.2 424 147 22.0 0.46 12 2.11 8.1 420 146 20.3 0.44 12 2.06 7.9 407 141 105ºF 18.8 0.95 18 2.10 8.3 417 133 18.2 0.91 19 2.09 8.2 413 131 16.8 0.88 19 2.04 8.0 400 127 59 18.4 0.84 16 2.09 8.2 413 131 17.9 0.80 16 2.07 8.2 408 130 16.5 0.77 17 2.02 7.9 396 126 19.3 0.85 17 2.15 8.5 448 141 18.8 0.81 18 2.13 8.4 444 140 17.3 0.78 18 2.08 8.2 431 135 63 19.1 0.70 14 2.13 8.4 444 140 18.6 0.67 14 2.11 8.4 440 138 17.1 0.64 14 2.06 8.1 426 134 20.9 0.65 14 2.22 8.8 474 154 20.3 0.62 14 2.20 8.7 469 152 18.7 0.59 15 2.15 8.5 455 148 67 21.0 0.49 10 2.20 8.7 469 152 20.3 0.46 11 2.18 8.6 464 151 18.8 0.45 11 2.13 8.4 450 146 22.4 0.42 10 2.29 9.1 494 164 21.8 0.40 10 2.27 9.1 489 162 20.1 0.38 10 2.22 8.8 474 157 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 24.2 0.41 10 2.21 8.6 447 158 23.5 0.39 11 2.20 8.5 443 157 21.7 0.38 11 2.14 8.3 429 152 - 71 115ºF Expanded Cooling Data — ANX130241B* / CA*F3030*6D* SS-ANX13 SS-ANX13 www.amana-hac.com 700 800 900 700 800 900 23.7 0.95 23 1.66 6.0 235 108 23.0 0.91 24 1.65 5.9 233 107 21.3 0.88 25 1.61 5.8 226 104 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR 59 23.3 0.91 22 1.65 5.9 233 107 22.6 0.87 23 1.64 5.9 231 106 20.9 0.84 23 1.60 5.7 224 103 MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR MBh S/T ∆T kW Amps Hi PR Lo PR Airflow 63 24.2 0.92 23 1.70 6.1 253 115 23.5 0.88 24 1.69 6.1 251 114 21.7 0.85 24 1.65 5.9 243 110 23.8 0.85 21 1.69 6.1 251 114 23.1 0.81 22 1.67 6.0 248 113 21.4 0.79 22 1.63 5.9 241 109 67 25.3 0.83 22 1.75 6.3 267 126 24.6 0.79 22 1.74 6.3 265 124 22.7 0.76 23 1.70 6.1 257 121 25.5 0.69 18 1.74 6.3 265 124 24.7 0.66 19 1.72 6.2 262 123 22.8 0.64 19 1.68 6.0 254 119 27.0 0.67 19 1.80 6.6 279 134 26.2 0.64 19 1.79 6.5 276 132 24.2 0.62 20 1.75 6.3 268 128 71 27.2 0.52 14 1.79 6.5 276 132 26.4 0.50 15 1.78 6.4 273 131 24.4 0.48 15 1.73 6.3 265 127 23.2 0.99 23 1.79 6.5 264 114 22.5 0.94 24 1.77 6.4 261 113 20.8 0.91 25 1.73 6.2 254 110 59 22.8 0.94 22 1.77 6.4 261 113 22.1 0.90 23 1.76 6.3 259 112 20.4 0.87 23 1.72 6.2 251 109 63 23.6 0.95 23 1.82 6.6 284 122 22.9 0.91 24 1.81 6.6 281 120 21.2 0.88 24 1.77 6.4 273 117 23.3 0.88 21 1.81 6.6 281 120 22.6 0.84 22 1.79 6.5 279 119 20.9 0.81 22 1.75 6.3 270 116 67 24.8 0.86 22 1.88 6.8 300 133 24.0 0.82 23 1.86 6.8 297 131 22.2 0.79 23 1.82 6.6 288 127 24.9 0.72 18 1.86 6.8 297 131 24.2 0.69 19 1.85 6.7 294 130 22.3 0.66 19 1.81 6.5 285 126 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 26.4 0.70 19 1.94 7.1 313 141 25.6 0.67 20 1.92 7.0 310 140 23.7 0.64 20 1.88 6.8 301 136 71 26.6 0.54 15 1.92 7.0 310 140 25.8 0.51 15 1.91 7.0 307 139 23.8 0.50 15 1.86 6.8 298 134 63 23.1 0.98 23 1.93 7.2 323 126 22.4 0.93 24 1.92 7.1 320 125 20.7 0.90 24 1.87 6.9 310 121 22.7 0.91 21 1.92 7.1 320 125 22.1 0.87 22 1.90 7.1 317 124 20.4 0.83 22 1.86 6.9 307 120 67 24.2 0.88 22 1.99 7.4 341 138 23.5 0.84 23 1.98 7.4 338 137 21.7 0.81 23 1.93 7.2 328 132 24.3 0.74 18 1.98 7.4 338 137 23.6 0.70 19 1.96 7.3 335 135 21.8 0.68 19 1.92 7.1 324 131 71 25.8 0.72 19 2.06 7.7 356 147 25.0 0.68 20 2.04 7.6 352 145 23.1 0.66 20 1.99 7.4 342 141 26.0 0.55 15 2.04 7.6 352 145 25.2 0.53 15 2.02 7.6 349 144 23.3 0.51 16 1.98 7.4 338 140 Shaded area reflects AHRI conditions 22.6 1.00 23 1.89 7.0 300 119 22.0 0.97 24 1.88 7.0 297 118 20.3 0.93 25 1.83 6.8 288 114 59 22.2 0.97 22 1.88 7.0 297 118 21.6 0.92 23 1.86 6.9 294 116 19.9 0.89 23 1.82 6.7 286 113 59 22.1 1.00 23 1.99 7.5 342 125 21.4 1.00 25 1.97 7.4 339 123 19.8 0.96 25 1.93 7.2 328 120 21.7 1.00 22 1.97 7.4 339 123 21.1 0.95 23 1.96 7.4 335 122 19.4 0.92 23 1.91 7.2 325 119 63 22.5 1.00 23 2.03 7.7 368 133 21.9 0.96 24 2.01 7.6 364 131 20.2 0.93 25 1.97 7.4 353 127 22.2 0.94 21 2.01 7.6 364 131 21.5 0.89 22 2.00 7.5 361 130 19.9 0.86 22 1.95 7.3 350 126 67 23.6 0.91 22 2.09 7.9 389 145 22.9 0.87 23 2.08 7.9 385 143 21.1 0.84 23 2.03 7.7 373 139 23.7 0.76 18 2.08 7.9 385 143 23.0 0.73 19 2.06 7.8 381 142 21.2 0.70 20 2.01 7.6 370 138 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 25.1 0.74 19 2.16 8.2 405 154 24.4 0.71 20 2.14 8.2 401 153 22.5 0.68 20 2.09 7.9 389 148 71 25.3 0.57 15 2.14 8.2 401 153 24.6 0.54 15 2.13 8.1 397 151 22.7 0.52 16 2.08 7.9 385 147 21.0 1.00 21 2.07 8.0 385 131 20.4 1.00 23 2.05 7.9 381 129 18.8 1.00 25 2.00 7.7 370 126 59 20.6 1.00 21 2.05 7.9 381 129 20.0 0.99 23 2.04 7.8 377 128 18.5 0.95 23 1.99 7.6 366 124 21.4 1.00 22 2.11 8.2 414 139 20.8 1.00 24 2.10 8.1 410 138 19.2 0.96 24 2.05 7.9 398 134 63 21.1 1.00 22 2.10 8.1 410 138 20.5 0.93 22 2.08 8.0 406 136 18.9 0.89 22 2.03 7.8 394 132 22.4 0.95 22 2.18 8.5 437 152 21.7 0.90 23 2.16 8.4 433 150 20.1 0.87 23 2.11 8.1 420 146 67 22.5 0.79 18 2.16 8.4 433 150 21.9 0.75 19 2.15 8.3 429 149 20.2 0.73 19 2.09 8.1 416 144 105ºF 19.4 1.00 20 2.14 8.5 425 135 18.9 1.00 22 2.12 8.4 421 134 17.4 1.00 23 2.07 8.2 408 130 59 19.1 1.00 20 2.12 8.4 421 134 18.5 1.00 21 2.10 8.3 417 133 17.1 0.96 22 2.05 8.1 404 129 19.8 1.00 20 2.18 8.7 457 144 19.2 1.00 22 2.17 8.6 453 142 17.7 0.97 23 2.11 8.4 439 138 63 19.5 1.00 20 2.17 8.6 453 142 18.9 0.93 20 2.15 8.5 448 141 17.5 0.90 21 2.10 8.3 435 137 20.7 0.95 20 2.25 9.0 483 157 20.1 0.91 21 2.24 8.9 478 155 18.6 0.88 21 2.18 8.6 464 151 67 20.8 0.80 17 2.24 8.9 478 155 20.2 0.76 18 2.22 8.8 474 154 18.7 0.73 18 2.16 8.6 459 149 22.1 0.77 17 2.33 9.3 504 167 21.5 0.74 18 2.31 9.2 499 166 19.8 0.71 19 2.25 9.0 484 161 71 22.3 0.60 14 2.31 9.2 499 166 21.6 0.57 14 2.29 9.1 494 164 20.0 0.55 14 2.23 8.9 479 159 Amps = outdoor unit amps (comp.+fan) kW = Total system power 23.9 0.77 19 2.25 8.8 456 162 23.2 0.73 20 2.23 8.7 452 160 21.4 0.71 20 2.18 8.5 438 155 71 24.1 0.59 15 2.23 8.7 452 160 23.4 0.56 15 2.21 8.6 447 158 21.6 0.54 15 2.16 8.4 434 154 115ºF Expanded Cooling Data — ANX130241B* / CA*F3030*6D* (cont.) 11 12 www.amana-hac.com 25.4 0.82 22 1.62 6.7 211 104 27.5 0.85 20 1.66 6.9 217 107 27.8 0.86 20 1.67 6.9 218 107 MBh S/T ∆T 875 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR 59 24.9 0.72 19 1.60 6.6 209 103 27.0 0.74 18 1.65 6.8 215 106 27.3 0.76 17 1.65 6.9 216 106 MBh S/T ∆T kW 875 Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR Airflow 63 26.1 0.73 20 1.66 6.9 227 110 28.3 0.76 19 1.70 7.1 234 114 28.6 0.77 18 1.71 7.1 234 114 25.8 0.60 16 1.64 6.8 224 109 28.0 0.62 15 1.69 7.0 231 113 28.3 0.63 15 1.69 7.0 232 113 67 28.3 0.55 16 1.72 7.1 239 121 30.6 0.57 15 1.76 7.3 247 124 30.9 0.58 15 1.77 7.4 248 125 28.3 0.42 12 1.70 7.0 237 119 30.7 0.43 12 1.75 7.3 244 123 31.0 0.44 11 1.75 7.3 245 123 30.3 0.36 11 1.78 7.4 250 128 32.9 0.37 11 1.83 7.6 257 132 33.2 0.38 10 1.83 7.7 258 133 - 71 24.8 0.85 22 1.76 7.3 236 110 26.8 0.88 21 1.81 7.5 244 113 27.1 0.89 20 1.81 7.5 245 113 59 24.4 0.74 19 1.74 7.2 234 109 26.4 0.77 18 1.79 7.4 241 112 26.7 0.79 17 1.80 7.5 242 112 63 25.5 0.76 20 1.80 7.5 254 117 27.6 0.78 19 1.85 7.7 262 120 27.9 0.80 18 1.86 7.7 263 121 25.2 0.62 16 1.78 7.4 252 116 27.4 0.64 15 1.83 7.6 260 119 27.6 0.66 15 1.84 7.7 260 119 67 27.6 0.57 17 1.87 7.7 269 127 29.9 0.59 16 1.92 8.0 277 131 30.2 0.61 15 1.92 8.0 278 132 27.7 0.43 13 1.85 7.7 266 126 30.0 0.45 12 1.90 7.9 274 130 30.3 0.45 11 1.91 7.9 275 130 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 29.6 0.37 11 1.93 8.1 280 136 32.1 0.38 11 1.99 8.3 289 140 32.4 0.39 10 1.99 8.3 290 140 - 71 63 24.9 0.78 20 1.93 8.2 289 121 27.0 0.80 19 1.98 8.4 298 125 27.2 0.82 18 1.99 8.5 299 125 24.6 0.64 16 1.91 8.1 286 120 26.7 0.66 15 1.97 8.3 295 124 27.0 0.67 15 1.97 8.4 296 124 67 26.9 0.59 17 2.00 8.5 306 132 29.2 0.61 16 2.06 8.7 315 136 29.5 0.62 15 2.06 8.8 316 137 27.0 0.44 13 1.98 8.4 303 131 29.3 0.46 12 2.04 8.6 312 135 29.5 0.47 11 2.04 8.7 313 136 28.9 0.38 11 2.07 8.8 319 141 31.3 0.39 11 2.13 9.1 329 145 31.6 0.40 10 2.14 9.1 330 146 - 71 59 23.6 0.89 22 1.99 8.6 306 120 25.6 0.93 21 2.05 8.8 316 123 25.8 0.95 20 2.06 8.9 317 124 23.2 0.79 19 1.97 8.5 303 119 25.1 0.82 18 2.03 8.7 313 122 25.4 0.83 17 2.04 8.8 314 123 Shaded area reflects ACCA (TVA) conditions 24.2 0.87 22 1.88 8.0 269 114 26.2 0.90 21 1.94 8.2 277 118 26.5 0.92 20 1.94 8.2 278 118 59 23.8 0.76 19 1.87 7.9 266 113 25.8 0.79 18 1.92 8.1 274 116 26.0 0.81 17 1.92 8.2 275 117 63 24.3 0.80 20 2.04 8.8 330 127 26.3 0.83 19 2.10 9.1 340 131 26.6 0.85 18 2.11 9.1 341 132 24.0 0.66 17 2.02 8.7 326 126 26.1 0.68 16 2.08 9.0 336 130 26.3 0.70 15 2.09 9.0 337 130 67 26.3 0.61 17 2.12 9.1 348 139 28.5 0.63 16 2.18 9.4 359 143 28.8 0.64 15 2.18 9.4 360 144 26.3 0.46 13 2.10 9.0 345 138 28.5 0.47 12 2.16 9.3 355 142 28.8 0.48 11 2.16 9.3 356 142 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 28.2 0.39 12 2.19 9.5 363 148 30.6 0.40 11 2.26 9.8 374 153 30.9 0.41 10 2.26 9.8 375 153 - 71 22.4 0.93 22 2.09 9.2 345 125 24.3 0.96 20 2.15 9.4 355 129 24.5 0.98 20 2.15 9.5 356 130 59 22.0 0.82 19 2.07 9.1 341 124 23.9 0.85 18 2.13 9.3 352 128 24.1 0.86 17 2.13 9.4 353 128 23.1 0.83 20 2.14 9.4 371 134 25.0 0.86 19 2.20 9.7 382 138 25.3 0.88 18 2.21 9.7 383 138 63 22.8 0.68 16 2.12 9.3 367 132 24.7 0.71 15 2.18 9.6 378 136 25.0 0.72 15 2.18 9.6 380 137 25.0 0.63 16 2.22 9.7 392 146 27.1 0.65 15 2.28 10.0 404 150 27.3 0.66 15 2.29 10.1 405 151 67 25.0 0.47 12 2.20 9.6 388 144 27.1 0.49 12 2.26 9.9 400 149 27.4 0.50 11 2.26 10.0 401 149 105ºF 20.8 0.94 20 2.17 9.7 381 130 22.5 0.97 19 2.23 10.0 393 134 22.7 0.99 18 2.24 10.1 394 134 59 20.4 0.82 18 2.15 9.6 377 128 22.1 0.85 17 2.21 9.9 389 132 22.3 0.87 16 2.21 10.0 390 133 21.4 0.84 19 2.22 10.0 410 138 23.2 0.87 18 2.28 10.3 422 142 23.4 0.89 17 2.29 10.3 424 143 63 21.2 0.69 15 2.20 9.9 406 137 22.9 0.71 14 2.26 10.2 418 141 23.2 0.73 14 2.27 10.2 419 141 23.1 0.63 15 2.30 10.4 433 151 25.1 0.66 14 2.37 10.7 446 155 25.3 0.67 14 2.37 10.7 447 156 67 23.2 0.48 12 2.28 10.2 428 149 25.1 0.49 11 2.35 10.6 442 154 25.4 0.50 10 2.35 10.6 443 154 24.8 0.41 11 2.39 10.8 451 161 26.9 0.42 10 2.46 11.1 465 166 27.2 0.43 10 2.46 11.1 467 166 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 26.8 0.40 11 2.30 10.1 408 155 29.0 0.42 11 2.36 10.4 421 160 29.3 0.43 10 2.37 10.5 422 161 - 71 115ºF Expanded Cooling Data — ANX130301B* / CA*F3030*6D*+EEP SS-ANX13 SS-ANX13 www.amana-hac.com 26.3 0.94 26 1.65 6.8 215 106 28.5 0.97 24 1.69 7.0 222 109 28.7 0.99 23 1.70 7.1 222 110 MBh S/T ∆T 875 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR 59 25.8 0.89 24 1.63 6.8 213 105 28.0 0.93 23 1.68 7.0 219 108 28.2 0.95 22 1.68 7.0 220 108 MBh S/T ∆T kW 875 Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR Airflow 63 26.8 0.90 25 1.69 7.0 231 113 29.0 0.94 24 1.73 7.2 239 116 29.3 0.96 23 1.74 7.2 239 117 26.4 0.84 23 1.67 6.9 229 112 28.6 0.87 22 1.72 7.2 236 115 28.9 0.89 21 1.72 7.2 237 115 67 28.0 0.82 24 1.75 7.3 244 123 30.4 0.85 23 1.80 7.5 252 127 30.7 0.86 22 1.80 7.5 253 127 28.2 0.68 20 1.73 7.2 242 122 30.5 0.71 19 1.78 7.4 249 126 30.8 0.72 18 1.78 7.4 250 126 29.9 0.66 21 1.81 7.6 255 131 32.4 0.69 19 1.86 7.8 263 135 32.7 0.70 19 1.87 7.8 263 135 71 30.1 0.5 16 1.8 7.5 252.3 129.7 32.6 0.5 15 1.8 7.7 260.1 133.7 33.0 0.5 15 1.8 7.7 260.9 134.1 25.7 0.97 26 1.79 7.4 241 112 27.8 1.00 24 1.84 7.7 249 115 28.1 1.00 23 1.85 7.7 249 116 59 25.2 0.93 25 1.77 7.4 239 111 27.3 0.96 23 1.82 7.6 246 114 27.6 0.98 22 1.83 7.6 247 115 63 26.1 0.94 26 1.83 7.6 260 119 28.3 0.97 24 1.89 7.9 268 123 28.6 0.99 23 1.89 7.9 268 123 25.8 0.87 24 1.82 7.6 257 118 27.9 0.90 22 1.87 7.8 265 122 28.2 0.92 21 1.87 7.8 266 122 67 27.4 0.85 24 1.90 7.9 274 130 29.7 0.88 23 1.95 8.1 283 134 30.0 0.90 22 1.96 8.2 283 134 27.5 0.71 20 1.88 7.8 271 129 29.8 0.73 19 1.94 8.1 280 133 30.1 0.75 18 1.94 8.1 281 133 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 29.2 0.69 21 1.97 8.2 286 138 31.7 0.71 20 2.03 8.5 295 143 32.0 0.73 19 2.03 8.5 296 143 71 29.4 0.53 16 1.95 8.1 283 137 31.9 0.55 15 2.01 8.4 292 141 32.2 0.56 15 2.01 8.4 293 142 63 25.5 0.96 26 1.96 8.3 295 124 27.7 1.00 24 2.02 8.6 304 128 27.9 1.00 23 2.03 8.6 305 128 25.1 0.89 24 1.95 8.3 292 123 27.2 0.92 22 2.00 8.5 301 126 27.5 0.94 21 2.01 8.5 302 127 67 26.7 0.87 24 2.04 8.6 312 135 29.0 0.90 23 2.09 8.9 321 139 29.3 0.92 22 2.10 8.9 322 140 26.9 0.73 20 2.02 8.6 309 134 29.1 0.75 19 2.07 8.8 318 138 29.4 0.77 18 2.08 8.8 319 138 71 28.5 0.70 21 2.11 9.0 325 144 30.9 0.73 20 2.17 9.3 335 148 31.2 0.74 19 2.18 9.3 336 149 28.7 0.5 16 2.1 8.9 322.0 142.4 31.1 0.6 15 2.2 9.2 331.9 146.8 31.4 0.6 15 2.2 9.2 332.9 147.3 Shaded area reflects AHRI conditions 25.0 1.00 26 1.92 8.1 274 116 27.1 1.00 24 1.97 8.4 283 120 27.4 1.00 22 1.98 8.4 284 120 59 24.6 0.95 25 1.90 8.1 272 115 26.7 0.99 23 1.95 8.3 280 119 26.9 1.00 22 1.96 8.3 281 119 59 24.4 1.00 26 2.03 8.7 312 122 26.5 1.00 23 2.09 9.0 322 126 26.7 1.00 22 2.09 9.0 323 126 24.0 0.98 25 2.01 8.7 309 121 26.0 1.00 23 2.07 8.9 319 125 26.3 1.00 21 2.07 8.9 320 125 63 24.9 0.99 26 2.08 9.0 336 130 27.0 1.00 24 2.14 9.2 347 134 27.3 1.00 22 2.15 9.3 348 134 24.5 0.92 24 2.06 8.9 333 129 26.6 0.95 22 2.12 9.1 343 133 26.8 0.97 21 2.13 9.2 344 133 67 26.1 0.90 25 2.16 9.3 355 142 28.3 0.93 23 2.22 9.6 366 146 28.5 0.95 22 2.22 9.6 367 147 26.2 0.75 21 2.14 9.2 352 140 28.4 0.78 19 2.20 9.5 362 145 28.7 0.79 19 2.20 9.5 364 145 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 27.8 0.73 21 2.24 9.7 370 151 30.1 0.75 20 2.30 10.0 382 156 30.4 0.77 19 2.31 10.0 383 156 71 28.0 0.56 16 2.21 9.6 367 150 30.4 0.58 15 2.28 9.9 378 154 30.7 0.59 15 2.28 9.9 379 155 23.2 1.00 24 2.13 9.3 352 128 25.1 1.00 22 2.19 9.6 362 132 25.4 1.00 21 2.19 9.7 364 132 59 22.8 1.02 24 2.11 9.2 348 127 24.7 1.00 22 2.17 9.5 359 131 25.0 1.00 20 2.17 9.6 360 131 23.7 1.00 25 2.18 9.6 378 136 25.6 1.00 22 2.24 9.9 390 140 25.9 1.00 21 2.25 9.9 391 141 63 23.3 0.96 23 2.16 9.5 375 135 25.3 0.99 22 2.22 9.8 386 139 25.5 1.00 21 2.23 9.8 387 139 24.8 0.93 24 2.26 9.9 399 149 26.8 0.96 23 2.32 10.2 412 153 27.1 0.98 22 2.33 10.3 413 154 67 24.9 0.78 20 2.24 9.8 396 147 27.0 0.81 19 2.30 10.1 408 152 27.2 0.82 18 2.31 10.2 409 152 105ºF 21.5 1.00 23 2.21 9.9 388 132 23.3 1.00 20 2.27 10.2 400 137 23.5 1.00 19 2.28 10.3 402 137 59 21.1 1.03 23 2.19 9.8 385 131 22.9 1.00 20 2.25 10.1 396 135 23.1 1.00 19 2.26 10.2 398 136 21.9 1.00 23 2.26 10.2 418 141 23.7 1.00 21 2.33 10.5 431 145 24.0 1.00 20 2.33 10.5 432 146 63 21.6 0.96 22 2.24 10.1 414 139 23.4 1.00 20 2.31 10.4 427 144 23.6 1.00 19 2.31 10.4 428 144 23.0 0.94 23 2.35 10.6 441 154 24.9 0.97 21 2.41 10.9 455 159 25.1 0.99 20 2.42 10.9 456 159 67 23.1 0.78 19 2.32 10.5 437 152 25.0 0.81 18 2.39 10.8 451 157 25.2 0.83 17 2.40 10.8 452 157 24.5 0.76 20 2.43 11.0 460 164 26.5 0.79 18 2.50 11.3 475 169 26.8 0.80 18 2.51 11.4 476 169 71 24.7 0.59 15 2.41 10.9 456 162 26.7 0.61 14 2.48 11.2 470 167 27.0 0.62 14 2.49 11.2 471 168 Amps = outdoor unit amps (comp.+fan) kW = Total system power 26.4 0.75 21 2.34 10.3 417 158 28.6 0.78 20 2.41 10.6 430 163 28.9 0.80 19 2.42 10.7 431 164 71 26.6 0.6 16 2.3 10.2 412.5 156.8 28.8 0.6 15 2.4 10.5 425.3 161.6 29.1 0.6 15 2.4 10.6 426.6 162.1 115ºF Expanded Cooling Data — ANX130301B* / CA*F3030*6D*+EEP (cont.) 13 14 www.amana-hac.com 30.0 0.77 20 2.34 8.6 237 102 32.5 0.80 20 2.40 8.8 244 105 33.5 0.84 19 2.41 8.9 247 106 MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1200 kW Amps HI PR LO PR MBh S/T ∆T 1350 kW Amps HI PR LO PR 59 29.5 0.68 18 2.32 8.5 235 101 32.0 0.71 17 2.38 8.8 242 104 32.9 0.74 17 2.40 8.8 244 105 MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1200 kW Amps HI PR LO PR MBh S/T ∆T 1350 kW Amps HI PR LO PR Airflow 63 30.9 0.69 19 2.39 8.8 255 108 33.5 0.72 18 2.45 9.1 263 112 34.5 0.75 18 2.46 9.2 266 113 30.6 0.57 15 2.37 8.7 252 107 33.1 0.59 15 2.43 9.0 260 111 34.1 0.62 14 2.45 9.1 263 112 67 33.4 0.52 15 2.46 9.1 269 118 36.2 0.54 15 2.52 9.4 278 122 37.3 0.57 14 2.54 9.5 280 123 33.5 0.39 12 2.44 9.0 267 117 36.3 0.41 11 2.50 9.3 275 121 37.4 0.43 11 2.52 9.4 278 122 35.9 0.34 11 2.54 9.5 281 126 38.9 0.35 10 2.60 9.7 290 130 40.0 0.37 10 2.62 9.8 292 131 - 71 29.3 0.80 21 2.51 9.3 266 108 31.8 0.83 20 2.58 9.6 274 111 32.7 0.87 19 2.60 9.7 277 112 59 28.8 0.70 18 2.49 9.2 263 107 31.2 0.73 17 2.56 9.5 271 110 32.2 0.77 17 2.58 9.6 274 111 63 30.2 0.72 19 2.57 9.6 286 114 32.7 0.74 19 2.63 9.8 295 118 33.7 0.78 18 2.65 9.9 298 119 29.9 0.59 15 2.55 9.5 283 113 32.4 0.61 15 2.61 9.7 292 117 33.3 0.64 15 2.63 9.8 295 118 67 32.7 0.54 16 2.65 9.9 302 125 35.4 0.56 15 2.71 10.2 312 129 36.4 0.59 15 2.73 10.3 315 130 32.7 0.41 12 2.63 9.8 299 124 35.5 0.42 11 2.69 10.1 308 128 36.5 0.44 11 2.71 10.2 311 129 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 35.1 0.35 11 2.73 10.3 315 133 38.0 0.36 11 2.80 10.6 325 137 39.1 0.38 10 2.82 10.7 328 139 - 71 63 29.5 0.73 19 2.72 10.4 325 119 31.9 0.76 19 2.79 10.7 336 123 32.9 0.80 18 2.81 10.8 339 124 29.2 0.60 15 2.70 10.3 322 118 31.6 0.63 15 2.77 10.6 332 121 32.5 0.66 15 2.79 10.7 335 123 67 31.9 0.56 16 2.81 10.8 344 130 34.5 0.58 15 2.88 11.1 354 134 35.6 0.60 15 2.90 11.2 358 135 31.9 0.42 12 2.79 10.7 340 129 34.6 0.43 11 2.86 11.0 351 133 35.7 0.45 11 2.88 11.1 354 134 34.2 0.36 11 2.90 11.2 358 138 37.1 0.37 11 2.97 11.5 370 143 38.2 0.39 10 3.00 11.6 373 144 - 71 59 27.9 0.85 21 2.80 10.9 344 117 30.2 0.88 20 2.87 11.2 355 121 31.1 0.92 20 2.90 11.3 359 122 27.4 0.75 18 2.78 10.8 341 116 29.7 0.77 18 2.85 11.1 352 120 30.6 0.81 17 2.87 11.2 355 121 Shaded area reflects ACCA (TVA) conditions 28.6 0.82 21 2.67 10.2 302 112 31.0 0.85 20 2.73 10.5 312 115 31.9 0.89 19 2.76 10.6 315 116 59 28.1 0.72 18 2.65 10.1 299 111 30.5 0.75 17 2.71 10.4 309 114 31.4 0.79 17 2.73 10.5 312 115 63 28.7 0.76 19 2.86 11.2 371 125 31.1 0.79 19 2.94 11.5 382 129 32.1 0.82 18 2.96 11.6 386 130 28.4 0.62 16 2.84 11.1 367 124 30.8 0.65 15 2.91 11.4 378 128 31.7 0.68 15 2.93 11.5 382 129 67 31.1 0.57 16 2.96 11.6 391 136 33.7 0.60 15 3.03 11.9 404 141 34.7 0.62 15 3.05 12.0 408 142 31.2 0.43 12 2.93 11.4 387 135 33.8 0.45 12 3.00 11.8 399 139 34.8 0.47 11 3.03 11.9 403 141 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 33.4 0.37 11 3.05 12.0 408 145 36.2 0.38 11 3.13 12.4 421 150 37.3 0.40 10 3.15 12.5 425 151 - 71 26.5 0.88 20 2.92 11.6 388 123 28.7 0.91 20 2.99 12.0 399 127 29.6 0.96 19 3.02 12.1 403 128 59 26.1 0.77 18 2.89 11.5 384 122 28.2 0.80 17 2.97 11.8 395 126 29.1 0.84 17 2.99 12.0 399 127 27.3 0.79 19 2.98 11.9 417 131 29.6 0.82 18 3.06 12.3 430 135 30.5 0.86 18 3.08 12.4 434 136 63 27.0 0.65 15 2.96 11.8 413 130 29.3 0.67 15 3.03 12.1 426 134 30.2 0.70 14 3.06 12.3 430 135 29.6 0.60 15 3.08 12.3 440 143 32.0 0.62 15 3.16 12.7 454 147 33.0 0.65 15 3.18 12.8 459 149 67 29.6 0.45 12 3.05 12.2 436 142 32.1 0.46 11 3.13 12.6 449 146 33.0 0.49 11 3.16 12.7 454 147 105ºF 24.6 0.89 19 3.02 12.3 428 127 26.6 0.92 19 3.09 12.7 441 131 27.4 0.96 18 3.12 12.8 446 133 59 24.2 0.78 17 2.99 12.2 424 126 26.2 0.81 16 3.07 12.6 437 130 27.0 0.85 16 3.09 12.7 441 131 25.3 0.79 18 3.08 12.6 461 135 27.4 0.82 17 3.16 13.0 475 140 28.2 0.86 17 3.19 13.2 480 141 63 25.0 0.65 14 3.06 12.5 456 134 27.1 0.68 14 3.14 12.9 470 138 27.9 0.71 13 3.16 13.0 475 140 27.4 0.60 14 3.18 13.1 487 148 29.7 0.62 14 3.27 13.5 502 152 30.5 0.65 14 3.29 13.6 507 154 67 27.4 0.45 11 3.16 13.0 482 146 29.7 0.47 11 3.24 13.3 497 151 30.6 0.49 10 3.26 13.5 501 152 29.4 0.39 10 3.29 13.6 507 158 31.8 0.40 10 3.37 14.0 523 162 32.8 0.42 9 3.40 14.1 528 164 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 31.7 0.38 11 3.18 12.8 459 152 34.4 0.40 10 3.26 13.2 473 157 35.4 0.42 10 3.29 13.3 478 159 - 71 115ºF Expanded Cooling Data — ANX130361A* / CA*F3636*6D*+EEP SS-ANX13 SS-ANX13 www.amana-hac.com 31.1 0.89 24 2.38 8.8 242 104 33.7 0.92 24 2.43 9.0 249 107 34.7 0.97 23 2.45 9.1 252 108 MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1200 kW Amps HI PR LO PR MBh S/T ∆T 1350 kW Amps HI PR LO PR 59 30.5 0.85 23 2.36 8.7 239 103 33.1 0.88 22 2.42 8.9 247 106 34.1 0.92 21 2.43 9.0 249 107 MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T 1200 kW Amps HI PR LO PR MBh S/T ∆T 1350 kW Amps HI PR LO PR Airflow 63 31.7 0.86 24 2.43 9.0 260 111 34.3 0.89 23 2.48 9.2 268 114 35.3 0.93 22 2.50 9.3 271 115 31.2 0.79 22 2.41 8.9 258 109 33.8 0.82 21 2.46 9.2 266 113 34.8 0.86 20 2.48 9.2 268 114 67 33.2 0.77 22 2.50 9.3 275 121 35.9 0.80 22 2.56 9.6 283 124 37.0 0.84 21 2.58 9.7 286 126 33.3 0.65 19 2.48 9.2 272 120 36.1 0.67 19 2.54 9.5 280 123 37.2 0.70 18 2.56 9.6 283 124 35.4 0.63 19 2.58 9.6 287 129 38.3 0.65 19 2.64 9.9 295 133 39.5 0.68 18 2.66 10.0 298 134 71 35.6 0.5 15 2.6 9.6 283.7 127.3 38.6 0.5 15 2.6 9.8 292.5 131.2 39.8 0.5 14 2.6 9.9 295.4 132.5 30.3 0.92 24 2.55 9.5 271 110 32.9 0.95 24 2.62 9.8 280 113 33.9 1.00 23 2.64 9.9 282 114 59 29.8 0.88 23 2.53 9.4 269 109 32.3 0.91 23 2.60 9.7 277 112 33.3 0.96 22 2.62 9.8 280 113 63 30.9 0.89 24 2.61 9.7 292 117 33.5 0.92 24 2.67 10.0 301 120 34.5 0.97 23 2.69 10.1 304 122 30.5 0.82 22 2.59 9.7 289 116 33.0 0.85 22 2.65 9.9 298 119 34.0 0.90 21 2.67 10.0 301 120 67 32.4 0.80 23 2.69 10.1 308 128 35.1 0.83 22 2.76 10.4 318 131 36.2 0.87 21 2.78 10.5 321 133 32.6 0.67 19 2.67 10.0 305 126 35.3 0.70 19 2.73 10.3 315 130 36.3 0.73 18 2.76 10.4 318 131 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 34.6 0.65 20 2.77 10.5 322 136 37.5 0.67 19 2.84 10.8 331 140 38.6 0.71 19 2.87 10.9 335 141 71 34.8 0.50 15 2.75 10.4 318 134 37.7 0.52 15 2.82 10.7 328 139 38.8 0.54 14 2.84 10.8 331 140 63 30.2 0.91 24 2.77 10.6 332 121 32.7 0.94 24 2.84 10.9 342 125 33.7 0.99 23 2.86 11.0 346 126 29.8 0.84 22 2.75 10.5 329 120 32.2 0.88 22 2.81 10.8 339 124 33.2 0.92 21 2.84 10.9 342 125 67 31.6 0.82 23 2.86 11.0 351 133 34.3 0.85 22 2.93 11.3 361 137 35.3 0.89 21 2.95 11.4 365 138 31.8 0.69 19 2.83 10.9 347 131 34.4 0.71 19 2.90 11.2 358 135 35.5 0.75 18 2.93 11.3 361 137 71 33.7 0.67 20 2.95 11.4 366 141 36.6 0.69 19 3.02 11.8 377 146 37.7 0.73 19 3.05 11.9 381 147 34.0 0.5 15 2.9 11.3 362.1 139.8 36.8 0.5 15 3.0 11.6 373.3 144.1 37.9 0.6 14 3.0 11.8 377.0 145.5 Shaded area reflects AHRI conditions 29.6 0.94 24 2.71 10.4 309 114 32.1 0.98 24 2.78 10.7 318 118 33.1 1.00 23 2.80 10.8 321 119 59 29.1 0.90 23 2.69 10.3 305 113 31.5 0.93 23 2.76 10.6 315 116 32.5 1.00 22 2.78 10.7 318 118 28.9 0.97 25 2.85 11.1 351 120 31.3 1.00 24 2.92 11.4 362 124 32.3 1.00 22 2.94 11.5 366 125 28.4 0.93 23 2.83 11.0 348 119 30.8 0.96 23 2.90 11.3 359 122 31.7 1.00 22 2.92 11.4 362 124 59 29.5 0.94 24 2.91 11.4 378 128 31.9 0.98 24 2.98 11.7 390 131 32.9 1.00 22 3.01 11.8 394 133 29.0 0.87 22 2.89 11.3 374 126 31.4 0.90 22 2.96 11.6 386 130 32.4 0.95 21 2.98 11.7 390 131 63 30.9 0.85 23 3.00 11.8 399 139 33.4 0.88 23 3.08 12.1 412 144 34.4 0.92 22 3.10 12.2 416 145 31.0 0.71 19 2.98 11.7 395 138 33.6 0.74 19 3.05 12.0 408 142 34.6 0.77 18 3.08 12.1 412 144 67 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 32.9 0.69 20 3.10 12.2 416 148 35.7 0.71 20 3.18 12.6 429 153 36.7 0.75 19 3.21 12.7 434 154 71 33.2 0.53 15 3.08 12.1 412 147 35.9 0.55 15 3.15 12.5 425 151 37.0 0.58 15 3.18 12.6 429 153 27.5 1.00 24 2.97 11.8 395 126 29.7 1.00 23 3.04 12.2 408 130 30.6 1.00 21 3.07 12.3 412 131 59 27.0 0.96 23 2.94 11.7 391 124 29.2 1.00 22 3.02 12.1 404 128 30.1 1.00 21 3.04 12.2 408 130 28.0 0.98 24 3.03 12.1 425 134 30.3 1.00 23 3.11 12.5 439 138 31.2 1.00 21 3.13 12.6 443 139 63 27.6 0.90 22 3.01 12.0 421 132 29.9 0.94 21 3.08 12.4 434 136 30.8 1.00 21 3.11 12.5 439 138 29.3 0.88 23 3.13 12.6 449 146 31.8 0.91 22 3.21 12.9 463 150 32.7 0.96 21 3.24 13.1 468 152 67 29.5 0.74 19 3.10 12.4 445 144 31.9 0.76 19 3.18 12.8 459 149 32.9 0.80 18 3.21 12.9 463 150 105ºF 25.4 1.00 22 3.07 12.6 437 130 27.6 1.00 21 3.15 12.9 450 134 28.4 1.00 19 3.17 13.1 455 135 59 25.0 0.97 21 3.04 12.5 432 129 27.1 1.00 21 3.12 12.8 446 133 27.9 1.00 19 3.15 12.9 450 134 25.9 0.98 22 3.13 12.9 470 138 28.1 1.00 22 3.21 13.3 485 143 28.9 1.00 20 3.24 13.4 489 144 63 25.5 0.91 20 3.11 12.8 465 137 27.7 0.95 20 3.19 13.2 480 141 28.5 1.00 19 3.21 13.3 485 143 27.2 0.89 21 3.24 13.3 496 151 29.4 0.92 21 3.32 13.7 512 156 30.3 0.97 20 3.35 13.9 517 157 67 27.3 0.74 18 3.21 13.2 491 149 29.6 0.77 17 3.29 13.6 507 154 30.5 0.81 17 3.32 13.7 512 156 29.0 0.72 18 3.34 13.9 518 161 31.4 0.75 18 3.43 14.3 534 166 32.3 0.78 17 3.46 14.4 539 167 71 29.2 0.56 14 3.32 13.7 513 159 31.6 0.58 14 3.40 14.1 528 164 32.6 0.60 13 3.43 14.3 534 166 Amps = outdoor unit amps (comp.+fan) kW = Total system power 31.3 0.71 20 3.23 13.1 469 155 33.9 0.74 19 3.32 13.4 483 160 34.9 0.78 18 3.34 13.6 488 162 71 31.5 0.6 15 3.2 12.9 463.9 153.8 34.1 0.6 15 3.3 13.3 478.3 158.6 35.1 0.6 14 3.3 13.4 483.1 160.2 115ºF Expanded Cooling Data — ANX130361A* / CA*F3636*6D*+EEP (cont.) 15 16 www.amana-hac.com 35.7 0.82 22 2.83 10.4 222 102 38.7 0.85 22 2.89 10.7 229 105 39.9 0.90 21 2.91 10.8 231 106 MBh S/T ∆T 1225 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR 59 35.1 0.72 19 2.81 10.3 220 101 38.1 0.75 19 2.87 10.6 227 104 39.2 0.79 18 2.89 10.7 229 105 MBh S/T ∆T 1225 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR Airflow 63 36.8 0.74 20 2.88 10.7 239 108 39.8 0.76 20 2.95 11.0 247 112 41.0 0.80 19 2.97 11.1 249 113 36.4 0.60 17 2.86 10.6 237 107 39.4 0.63 16 2.92 10.9 244 111 40.6 0.66 16 2.94 11.0 247 112 67 39.8 0.56 17 2.96 11.0 253 118 43.1 0.58 16 3.03 11.3 260 122 44.4 0.61 16 3.05 11.4 263 123 39.9 0.42 13 2.94 10.9 250 117 43.2 0.43 12 3.01 11.2 258 121 44.5 0.46 12 3.03 11.3 260 122 42.7 0.36 11 3.05 11.4 263 126 46.3 0.37 11 3.12 11.7 272 130 47.7 0.39 11 3.14 11.8 274 131 - 71 34.9 0.85 22 3.02 11.2 249 108 37.8 0.88 22 3.09 11.6 257 111 38.9 0.93 21 3.12 11.7 260 112 59 34.3 0.75 19 3.00 11.1 247 107 37.2 0.78 19 3.07 11.5 255 110 38.3 0.82 18 3.09 11.6 257 111 63 35.9 0.76 21 3.08 11.5 268 115 38.9 0.79 20 3.15 11.8 277 118 40.1 0.83 19 3.18 11.9 279 119 35.6 0.63 17 3.06 11.4 266 113 38.5 0.65 16 3.13 11.7 274 117 39.7 0.68 16 3.15 11.8 277 118 67 38.9 0.58 17 3.17 11.9 283 125 42.1 0.60 17 3.25 12.2 292 129 43.4 0.63 16 3.27 12.3 295 130 39.0 0.43 13 3.15 11.8 281 124 42.2 0.45 12 3.22 12.1 289 128 43.5 0.47 12 3.25 12.2 292 129 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 41.7 0.37 12 3.27 12.3 296 133 45.2 0.39 11 3.35 12.7 305 137 46.6 0.40 11 3.37 12.8 308 139 - 71 63 35.1 0.78 21 3.26 12.5 305 119 38.0 0.81 20 3.34 12.8 315 123 39.1 0.85 19 3.36 13.0 318 124 34.7 0.64 17 3.24 12.4 302 118 37.6 0.67 16 3.31 12.7 312 122 38.7 0.70 16 3.34 12.8 315 123 67 38.0 0.59 17 3.36 12.9 322 130 41.1 0.61 17 3.44 13.3 332 134 42.4 0.64 16 3.47 13.4 336 135 38.0 0.45 13 3.33 12.8 319 129 41.2 0.46 12 3.41 13.1 329 133 42.4 0.48 12 3.44 13.3 332 134 40.7 0.38 12 3.46 13.4 336 138 44.1 0.40 11 3.54 13.8 347 143 45.5 0.41 11 3.57 13.9 350 144 - 71 59 33.2 0.90 23 3.35 13.0 323 118 36.0 0.94 22 3.43 13.4 333 121 37.1 0.98 21 3.46 13.5 336 122 32.7 0.79 19 3.33 12.9 320 116 35.4 0.82 19 3.40 13.3 330 120 36.5 0.86 18 3.43 13.4 333 121 Shaded area reflects ACCA (TVA) conditions 34.1 0.87 22 3.20 12.2 284 112 36.9 0.91 22 3.27 12.5 292 115 38.0 0.95 21 3.30 12.7 295 117 59 33.5 0.77 19 3.17 12.1 281 111 36.3 0.80 19 3.25 12.4 289 114 37.4 0.84 18 3.27 12.5 292 115 63 34.2 0.81 21 3.42 13.3 348 125 37.1 0.84 20 3.50 13.7 358 129 38.2 0.88 20 3.53 13.8 362 130 33.9 0.66 17 3.39 13.2 344 124 36.7 0.69 17 3.47 13.6 355 128 37.8 0.72 16 3.50 13.7 358 129 67 37.0 0.61 17 3.52 13.8 367 137 40.1 0.63 17 3.61 14.2 378 141 41.3 0.66 16 3.64 14.3 382 142 37.1 0.46 13 3.50 13.7 363 135 40.2 0.48 13 3.58 14.0 375 139 41.4 0.50 12 3.61 14.2 378 141 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 39.7 0.39 12 3.63 14.3 383 145 43.1 0.41 12 3.72 14.7 395 150 44.4 0.43 11 3.75 14.8 399 151 - 71 31.6 0.94 22 3.48 13.9 363 123 34.2 0.97 22 3.57 14.3 375 127 35.2 1.00 21 3.59 14.4 378 128 59 31.0 0.82 19 3.45 13.7 360 122 33.6 0.86 19 3.54 14.1 371 126 34.6 0.90 18 3.56 14.2 375 127 32.5 0.84 20 3.55 14.2 391 131 35.2 0.87 20 3.64 14.6 403 135 36.3 0.91 19 3.67 14.7 407 136 63 32.2 0.69 17 3.53 14.1 387 130 34.9 0.71 16 3.61 14.5 399 134 35.9 0.75 16 3.64 14.6 403 135 35.2 0.63 17 3.66 14.7 413 143 38.1 0.66 16 3.75 15.1 426 148 39.3 0.69 16 3.78 15.2 430 149 67 35.2 0.48 13 3.63 14.5 409 142 38.2 0.49 12 3.72 14.9 421 146 39.3 0.52 12 3.75 15.1 426 148 105ºF 29.2 0.95 21 3.59 14.7 402 127 31.7 0.98 20 3.68 15.1 414 131 32.6 1.00 19 3.71 15.2 418 133 59 28.8 0.83 18 3.57 14.5 398 126 31.2 0.86 18 3.65 15.0 410 130 32.1 0.90 17 3.68 15.1 414 131 30.1 0.85 19 3.67 15.0 432 136 32.6 0.88 19 3.76 15.5 446 140 33.6 0.92 18 3.79 15.6 450 141 63 29.8 0.69 16 3.64 14.9 428 134 32.3 0.72 15 3.73 15.3 441 138 33.3 0.76 15 3.76 15.5 445 140 32.6 0.64 16 3.78 15.5 456 148 35.3 0.66 15 3.88 16.0 470 153 36.4 0.70 15 3.91 16.1 475 154 67 32.7 0.48 12 3.75 15.4 452 147 35.4 0.50 12 3.84 15.8 466 151 36.4 0.52 11 3.87 16.0 470 153 35.0 0.41 11 3.90 16.1 476 158 37.9 0.43 11 4.00 16.6 491 163 39.0 0.45 10 4.03 16.7 496 164 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 37.8 0.41 12 3.78 15.2 431 152 40.9 0.42 11 3.87 15.7 444 157 42.1 0.44 11 3.90 15.8 449 159 - 71 115ºF Expanded Cooling Data — ANX130421A* / CA*F3642*6D*+EEP SS-ANX13 SS-ANX13 www.amana-hac.com 37.0 0.95 26 2.87 10.6 227 104 40.1 0.98 26 2.93 10.9 234 107 41.3 1.00 24 2.95 11.0 236 108 MBh S/T ∆T 1225 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR 59 36.4 0.90 25 2.85 10.5 225 103 39.4 0.94 24 2.91 10.8 231 106 40.6 1.00 24 2.93 10.9 234 107 MBh S/T ∆T 1225 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR Airflow 63 37.7 0.91 26 2.92 10.9 244 111 40.9 0.95 25 2.99 11.2 252 114 42.1 0.99 24 3.01 11.3 254 115 37.1 0.85 24 2.90 10.8 242 110 40.2 0.88 23 2.97 11.1 249 113 41.5 0.92 22 2.99 11.2 252 114 67 39.5 0.82 24 3.01 11.2 258 121 42.8 0.85 24 3.08 11.5 266 125 44.1 0.90 23 3.10 11.6 268 126 39.7 0.69 21 2.98 11.1 255 120 43.0 0.71 20 3.05 11.4 263 123 44.3 0.75 19 3.08 11.5 266 125 42.1 0.67 21 3.10 11.6 269 129 45.6 0.69 21 3.17 11.9 277 133 47.0 0.73 20 3.19 12.0 280 134 71 42.4 0.5 16 3.1 11.5 266.1 127.4 46.0 0.5 16 3.1 11.8 274.3 131.3 47.3 0.6 15 3.2 11.9 277.1 132.6 36.1 0.98 27 3.07 11.5 254 110 39.1 1.00 26 3.14 11.8 262 113 40.3 1.00 24 3.16 11.9 265 114 59 35.5 0.94 25 3.05 11.4 252 109 38.5 0.97 25 3.12 11.7 260 112 39.6 1.00 23 3.14 11.8 262 113 63 36.8 0.95 26 3.13 11.7 274 117 39.9 0.98 26 3.20 12.0 282 121 41.1 1.00 24 3.23 12.2 285 122 36.3 0.88 24 3.11 11.6 271 116 39.3 0.91 23 3.18 11.9 279 119 40.5 0.95 23 3.20 12.0 282 121 67 38.6 0.85 25 3.22 12.1 289 128 41.8 0.89 24 3.30 12.4 298 132 43.0 0.93 23 3.32 12.6 301 133 38.8 0.71 21 3.20 12.0 286 126 42.0 0.74 20 3.27 12.3 295 130 43.3 0.78 20 3.30 12.4 298 132 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 41.2 0.69 21 3.32 12.6 302 136 44.6 0.72 21 3.40 12.9 311 140 45.9 0.75 20 3.42 13.0 314 142 71 41.4 0.53 17 3.29 12.4 299 135 44.9 0.55 16 3.37 12.8 308 139 46.2 0.58 16 3.40 12.9 311 140 63 36.0 0.97 26 3.31 12.7 311 121 39.0 1.00 26 3.39 13.1 321 125 40.1 1.00 23 3.42 13.2 324 126 35.4 0.90 24 3.29 12.6 308 120 38.4 0.93 24 3.36 13.0 318 124 39.5 1.00 23 3.39 13.1 321 125 67 37.7 0.88 25 3.41 13.1 329 133 40.8 0.91 24 3.49 13.5 339 137 42.0 0.95 23 3.52 13.6 342 138 37.8 0.73 21 3.39 13.0 326 131 41.0 0.76 20 3.47 13.4 336 135 42.2 0.80 20 3.49 13.5 339 137 71 40.2 0.71 21 3.52 13.6 343 141 43.5 0.74 21 3.60 14.0 354 146 44.8 0.77 20 3.63 14.1 357 147 40.5 0.5 17 3.5 13.5 339.6 139.8 43.8 0.6 16 3.6 13.9 350.1 144.2 45.1 0.6 16 3.6 14.0 353.6 145.6 Shaded area reflects AHRI conditions 35.3 1.00 26 3.25 12.4 289 114 38.2 1.00 25 3.32 12.8 298 118 39.4 1.00 23 3.35 12.9 301 119 59 34.7 0.96 25 3.22 12.3 287 113 37.6 1.00 25 3.30 12.7 295 117 38.7 1.00 23 3.32 12.8 298 118 59 34.4 1.00 26 3.40 13.3 330 120 37.3 1.00 24 3.48 13.6 340 124 38.4 1.00 22 3.51 13.8 343 125 33.8 0.99 25 3.38 13.2 326 119 36.6 1.00 24 3.46 13.5 336 122 37.7 1.00 22 3.48 13.6 340 124 63 35.1 1.00 26 3.47 13.6 355 128 38.0 1.00 25 3.56 14.0 366 132 39.1 1.00 23 3.58 14.1 369 133 34.6 0.93 24 3.45 13.5 351 126 37.4 0.96 24 3.53 13.9 362 130 38.6 1.00 23 3.56 14.0 366 132 67 36.7 0.90 25 3.58 14.0 375 139 39.8 0.94 25 3.66 14.4 386 144 41.0 0.98 24 3.69 14.6 390 145 36.9 0.76 21 3.55 13.9 371 138 40.0 0.78 21 3.64 14.3 382 142 41.2 0.82 20 3.66 14.4 386 144 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 39.2 0.73 22 3.69 14.6 391 148 42.5 0.76 21 3.78 15.0 403 153 43.7 0.80 20 3.81 15.1 407 154 71 39.5 0.57 17 3.66 14.4 387 147 42.8 0.59 16 3.75 14.8 399 151 44.0 0.61 16 3.78 15.0 403 153 32.7 1.00 25 3.54 14.1 371 126 35.4 1.00 23 3.62 14.5 382 130 36.5 1.00 21 3.65 14.6 386 131 59 32.1 1.03 25 3.51 14.0 367 124 34.8 1.00 23 3.59 14.4 378 128 35.9 1.00 21 3.62 14.5 382 130 33.3 1.00 25 3.61 14.5 399 134 36.1 1.00 24 3.70 14.9 411 138 37.2 1.00 22 3.73 15.0 415 139 63 32.8 0.96 24 3.58 14.3 395 132 35.6 1.00 23 3.67 14.7 407 137 36.6 1.00 21 3.70 14.9 411 138 34.9 0.94 25 3.72 14.9 421 146 37.8 0.97 24 3.81 15.4 434 151 38.9 1.00 23 3.84 15.5 439 152 67 35.1 0.78 21 3.69 14.8 417 145 38.0 0.81 20 3.78 15.2 430 149 39.1 0.85 19 3.81 15.4 434 151 105ºF 30.3 1.00 23 3.65 14.9 410 130 32.8 1.00 22 3.74 15.4 422 134 33.8 1.00 20 3.77 15.5 427 135 59 29.8 1.04 23 3.62 14.8 406 129 32.2 1.00 21 3.71 15.2 418 133 33.2 1.00 19 3.74 15.4 422 134 30.9 1.00 23 3.73 15.3 441 138 33.4 1.00 22 3.82 15.7 455 143 34.4 1.00 20 3.85 15.9 459 144 63 30.4 0.97 22 3.70 15.2 437 137 32.9 1.00 22 3.79 15.6 450 141 33.9 1.00 20 3.82 15.7 455 143 32.3 0.95 23 3.84 15.8 466 151 35.0 0.98 23 3.94 16.3 480 156 36.1 1.00 21 3.97 16.4 485 157 67 32.5 0.79 19 3.81 15.7 461 150 35.2 0.82 19 3.91 16.1 475 154 36.3 0.86 18 3.94 16.3 480 156 34.5 0.77 20 3.97 16.4 486 161 37.4 0.80 20 4.06 16.9 501 166 38.5 0.83 19 4.10 17.1 506 167 71 34.7 0.59 15 3.93 16.3 481 159 37.6 0.61 15 4.03 16.7 496 164 38.8 0.64 15 4.06 16.9 501 166 Amps = outdoor unit amps (comp.+fan) kW = Total system power 37.2 0.76 21 3.84 15.5 439 155 40.3 0.79 21 3.93 15.9 453 160 41.5 0.83 20 3.96 16.1 458 162 71 37.5 0.6 17 3.8 15.4 435.1 154.0 40.6 0.6 16 3.9 15.8 448.6 158.7 41.8 0.6 16 3.9 15.9 453.1 160.3 115ºF Cooling Data — ANX130421A* / CA*F3642*6D*+EEP (cont.) 17 18 www.amana-hac.com 41.1 0.80 22 3.24 11.9 243 105 44.5 0.83 21 3.31 12.3 251 108 45.8 0.87 20 3.34 12.4 253 109 MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR 59 40.4 0.71 19 3.22 11.8 241 104 43.8 0.73 18 3.29 12.2 248 107 45.1 0.77 18 3.31 12.3 251 108 MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR Airflow 63 42.3 0.72 20 3.30 12.2 262 111 45.8 0.75 20 3.38 12.6 270 115 47.2 0.78 19 3.40 12.7 273 116 41.9 0.59 16 3.28 12.1 259 110 45.4 0.61 16 3.35 12.5 267 114 46.7 0.64 15 3.38 12.6 270 115 67 45.8 0.54 16 3.40 12.6 276 122 49.6 0.56 16 3.48 13.0 285 125 51.1 0.59 15 3.50 13.1 288 127 45.9 0.41 12 3.37 12.5 274 120 49.7 0.42 12 3.45 12.9 282 124 51.2 0.44 12 3.48 13.0 285 125 49.1 0.35 11 3.50 13.1 288 130 53.2 0.36 11 3.58 13.5 297 134 54.8 0.38 11 3.61 13.6 300 135 - 71 40.1 0.83 22 3.47 12.9 273 111 43.5 0.86 22 3.55 13.3 281 114 44.8 0.91 21 3.58 13.4 284 115 59 39.5 0.73 19 3.44 12.8 270 110 42.7 0.76 19 3.52 13.1 279 113 44.0 0.80 18 3.55 13.3 281 114 63 41.3 0.74 20 3.54 13.2 294 118 44.8 0.77 20 3.62 13.6 303 121 46.1 0.81 19 3.65 13.7 306 123 40.9 0.61 16 3.51 13.1 291 117 44.3 0.63 16 3.59 13.5 300 120 45.6 0.67 16 3.62 13.6 303 121 67 44.7 0.56 17 3.64 13.7 310 129 48.4 0.58 16 3.73 14.0 320 132 49.9 0.61 16 3.76 14.2 323 134 44.8 0.42 12 3.62 13.5 307 127 48.5 0.44 12 3.70 13.9 317 131 50.0 0.46 12 3.73 14.0 320 132 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 48.0 0.36 11 3.75 14.2 324 137 52.0 0.38 11 3.84 14.6 334 141 53.6 0.39 11 3.87 14.7 337 143 - 71 63 40.3 0.76 20 3.75 14.4 334 122 43.7 0.79 20 3.83 14.8 344 126 45.0 0.83 19 3.86 14.9 348 127 39.9 0.63 16 3.72 14.2 331 121 43.2 0.65 16 3.80 14.6 341 125 44.5 0.68 16 3.83 14.8 344 126 67 43.7 0.58 17 3.86 14.8 353 134 47.3 0.60 16 3.95 15.3 364 138 48.7 0.63 16 3.98 15.4 367 139 43.7 0.43 12 3.83 14.7 349 132 47.4 0.45 12 3.92 15.1 360 136 48.8 0.47 12 3.95 15.3 364 138 46.8 0.37 11 3.98 15.4 368 142 50.8 0.39 11 4.08 15.8 379 147 52.3 0.40 11 4.11 16.0 383 148 - 71 59 38.2 0.88 22 3.85 15.0 354 121 41.4 0.91 22 3.94 15.4 365 125 42.6 0.96 21 3.97 15.6 368 126 37.6 0.78 19 3.82 14.8 350 120 40.7 0.80 19 3.91 15.3 361 123 41.9 0.84 18 3.94 15.4 365 125 Shaded area reflects ACCA (TVA) conditions 39.2 0.85 22 3.67 14.0 311 115 42.4 0.89 22 3.76 14.4 320 119 43.7 0.93 21 3.79 14.5 323 120 59 38.5 0.75 19 3.64 13.9 307 114 41.7 0.78 19 3.73 14.3 317 117 43.0 0.82 18 3.76 14.4 320 119 63 39.3 0.79 20 3.93 15.4 381 129 42.6 0.82 20 4.02 15.8 392 132 43.9 0.86 19 4.06 15.9 396 134 38.9 0.65 17 3.90 15.2 377 127 42.2 0.67 16 3.99 15.6 388 131 43.5 0.70 16 4.02 15.8 392 132 67 42.6 0.60 17 4.05 15.9 402 140 46.1 0.62 16 4.15 16.3 414 145 47.5 0.65 16 4.18 16.5 418 146 42.7 0.45 13 4.02 15.7 398 139 46.2 0.47 12 4.12 16.2 410 143 47.6 0.49 12 4.15 16.3 414 145 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 45.7 0.38 12 4.18 16.5 419 149 49.5 0.40 11 4.28 16.9 432 154 51.0 0.42 11 4.31 17.1 436 156 - 71 36.3 0.91 22 4.00 15.9 398 127 39.3 0.95 21 4.10 16.4 410 131 40.5 0.99 21 4.13 16.6 414 132 59 35.7 0.80 19 3.97 15.8 394 125 38.7 0.83 19 4.07 16.2 406 129 39.8 0.87 18 4.10 16.4 410 130 37.4 0.82 20 4.09 16.3 428 135 40.5 0.85 20 4.18 16.8 441 139 41.7 0.89 19 4.22 17.0 446 140 63 37.0 0.67 16 4.05 16.2 424 133 40.1 0.70 16 4.15 16.6 437 137 41.3 0.73 15 4.18 16.8 441 139 40.5 0.62 16 4.21 16.9 452 147 43.8 0.64 16 4.32 17.4 466 152 45.1 0.67 16 4.35 17.5 471 153 67 40.5 0.47 12 4.18 16.7 448 146 43.9 0.48 12 4.28 17.2 461 150 45.2 0.51 12 4.32 17.4 466 152 105ºF 33.6 0.92 20 4.13 16.9 440 131 36.4 0.96 20 4.23 17.4 453 135 37.5 1.00 19 4.27 17.5 458 136 59 33.1 0.81 18 4.10 16.7 435 130 35.8 0.84 17 4.20 17.2 449 134 36.9 0.88 17 4.23 17.4 453 135 34.6 0.82 19 4.22 17.3 473 139 37.5 0.86 18 4.32 17.8 488 144 38.6 0.90 18 4.36 18.0 493 145 63 34.3 0.68 15 4.19 17.1 468 138 37.1 0.70 15 4.29 17.6 483 142 38.2 0.74 14 4.32 17.8 488 144 37.5 0.62 15 4.35 17.9 500 152 40.6 0.65 15 4.46 18.4 515 157 41.8 0.68 14 4.50 18.6 520 158 67 37.5 0.47 12 4.32 17.7 494 151 40.7 0.49 11 4.42 18.2 510 155 41.9 0.51 11 4.46 18.4 515 157 40.2 0.40 11 4.49 18.6 521 162 43.6 0.42 10 4.60 19.1 537 167 44.9 0.44 10 4.64 19.3 543 169 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 43.4 0.40 11 4.35 17.5 472 157 47.0 0.41 11 4.45 18.0 486 161 48.5 0.43 11 4.49 18.2 491 163 - 71 115ºF Cooling Data — ANX130481A* / CA*F4860*6D*+EEP SS-ANX13 SS-ANX13 www.amana-hac.com 42.5 0.92 26 3.29 12.2 248 107 46.1 0.96 25 3.36 12.5 256 110 47.5 1.00 24 3.39 12.6 258 111 MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR 59 41.8 0.88 24 3.26 12.1 246 106 45.3 0.91 24 3.34 12.4 253 109 46.7 0.96 23 3.36 12.5 256 110 MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR Airflow 63 43.4 0.89 25 3.35 12.5 267 114 47.0 0.92 25 3.43 12.8 275 117 48.4 0.97 24 3.45 12.9 278 118 42.7 0.83 23 3.33 12.3 264 113 46.3 0.86 23 3.40 12.7 273 116 47.7 0.90 22 3.43 12.8 275 117 67 45.4 0.80 24 3.45 12.9 282 124 49.2 0.83 24 3.53 13.2 291 128 50.7 0.87 23 3.56 13.3 294 129 45.6 0.67 20 3.42 12.7 279 123 49.5 0.70 20 3.50 13.1 288 127 50.9 0.73 19 3.53 13.2 291 128 48.5 0.65 21 3.55 13.3 294 132 52.5 0.68 20 3.64 13.7 303 136 54.1 0.71 20 3.66 13.8 306 138 71 48.8 0.5 16 3.5 13.2 291.3 130.9 52.9 0.5 16 3.6 13.6 300.3 134.9 54.4 0.5 15 3.6 13.7 303.3 136.3 41.5 0.96 26 3.52 13.1 279 113 45.0 0.99 26 3.60 13.5 287 116 46.4 1.00 24 3.63 13.6 290 118 59 40.8 0.91 24 3.49 13.0 276 112 44.2 0.95 24 3.58 13.4 284 115 45.6 1.00 23 3.60 13.5 287 116 63 42.4 0.92 26 3.59 13.5 300 120 45.9 0.96 25 3.68 13.8 309 124 47.3 1.00 24 3.70 14.0 312 125 41.7 0.86 23 3.56 13.3 297 119 45.2 0.89 23 3.65 13.7 306 123 46.6 0.93 22 3.68 13.8 309 124 67 44.4 0.83 24 3.70 13.9 317 131 48.1 0.86 24 3.79 14.3 326 135 49.5 0.91 23 3.82 14.4 330 137 44.6 0.70 20 3.67 13.8 313 130 48.3 0.72 20 3.76 14.2 323 134 49.7 0.76 19 3.79 14.3 326 135 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 47.3 0.68 21 3.81 14.4 330 140 51.3 0.70 21 3.90 14.8 340 144 52.8 0.74 20 3.93 15.0 344 145 71 47.7 0.52 16 3.78 14.3 327 138 51.6 0.54 16 3.87 14.7 337 143 53.2 0.57 15 3.90 14.8 340 144 63 41.3 0.95 26 3.80 14.6 341 125 44.8 0.98 25 3.89 15.0 351 129 46.1 1.00 24 3.93 15.2 355 130 40.7 0.88 23 3.77 14.5 338 124 44.1 0.91 23 3.86 14.9 348 127 45.5 0.95 22 3.89 15.0 351 129 67 43.3 0.85 24 3.92 15.1 360 136 46.9 0.89 24 4.01 15.5 371 140 48.3 0.93 23 4.05 15.7 375 142 43.5 0.71 20 3.89 15.0 356 135 47.2 0.74 20 3.98 15.4 367 139 48.6 0.78 19 4.01 15.5 371 140 71 46.2 0.69 21 4.04 15.7 375 145 50.1 0.72 21 4.14 16.1 387 150 51.6 0.75 20 4.17 16.3 391 151 46.5 0.5 16 4.0 15.5 371.7 143.7 50.4 0.6 16 4.1 16.0 383.2 148.1 51.9 0.6 15 4.1 16.1 387.1 149.6 Shaded area reflects AHRI conditions 40.6 0.98 26 3.73 14.3 317 117 43.9 1.00 25 3.82 14.7 327 121 45.3 1.00 23 3.85 14.8 330 122 59 39.9 0.94 25 3.70 14.2 314 116 43.2 0.97 24 3.79 14.6 323 120 44.5 1.00 23 3.82 14.7 327 121 59 39.6 1.00 26 3.91 15.3 361 123 42.9 1.00 25 4.00 15.7 372 127 44.2 1.00 23 4.04 15.8 376 128 38.9 0.97 25 3.88 15.1 357 122 42.1 1.00 24 3.97 15.6 368 126 43.4 1.00 22 4.00 15.7 372 127 63 40.3 0.98 26 3.99 15.6 388 131 43.7 1.00 25 4.09 16.1 400 135 45.0 1.00 23 4.12 16.2 404 137 39.7 0.91 24 3.96 15.5 384 130 43.1 0.94 23 4.06 15.9 396 134 44.3 1.00 23 4.09 16.1 400 135 67 42.2 0.88 24 4.11 16.2 410 143 45.8 0.91 24 4.21 16.6 423 148 47.1 0.96 23 4.25 16.8 427 149 42.5 0.74 21 4.08 16.0 406 142 46.0 0.77 20 4.18 16.5 419 146 47.4 0.80 19 4.21 16.6 423 148 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 45.1 0.72 21 4.24 16.8 428 152 48.8 0.74 21 4.35 17.2 441 157 50.3 0.78 20 4.38 17.4 445 159 71 45.4 0.55 16 4.21 16.6 423 151 49.2 0.57 16 4.31 17.1 436 156 50.6 0.60 16 4.35 17.2 441 157 37.6 1.00 25 4.07 16.2 406 129 40.7 1.00 23 4.16 16.7 418 133 42.0 1.00 21 4.20 16.9 423 134 59 36.9 1.00 24 4.03 16.1 402 128 40.0 1.00 23 4.13 16.6 414 132 41.2 1.00 21 4.16 16.7 418 133 38.3 1.00 25 4.15 16.6 437 137 41.5 1.00 24 4.25 17.1 450 142 42.8 1.00 22 4.29 17.3 455 143 63 37.8 0.94 23 4.12 16.5 432 136 40.9 0.98 23 4.22 17.0 446 140 42.1 1.00 22 4.25 17.1 450 142 40.1 0.92 24 4.28 17.2 461 150 43.5 0.95 24 4.39 17.7 476 155 44.8 1.00 23 4.42 17.9 480 156 67 40.3 0.77 20 4.25 17.0 457 149 43.7 0.79 20 4.35 17.5 471 153 45.0 0.83 19 4.39 17.7 476 155 105ºF 34.8 1.00 23 4.20 17.2 448 134 37.7 1.00 22 4.30 17.7 462 138 38.9 1.00 20 4.34 17.9 467 139 59 34.2 1.01 23 4.17 17.1 444 132 37.1 1.00 21 4.27 17.5 458 136 38.2 1.00 20 4.30 17.7 462 138 35.5 1.00 23 4.29 17.6 483 142 38.5 1.00 22 4.39 18.1 498 147 39.6 1.00 20 4.43 18.3 503 148 63 35.0 0.95 22 4.25 17.5 478 141 37.9 0.98 21 4.36 18.0 493 145 39.0 1.00 20 4.39 18.1 498 147 37.2 0.92 23 4.42 18.2 510 155 40.3 0.96 22 4.53 18.8 525 160 41.5 1.00 21 4.57 18.9 531 162 67 37.4 0.77 19 4.39 18.1 505 154 40.5 0.80 19 4.50 18.6 520 158 41.7 0.84 18 4.53 18.8 525 160 39.7 0.75 20 4.56 18.9 532 165 43.0 0.78 19 4.68 19.5 548 170 44.3 0.81 18 4.72 19.7 553 172 71 39.9 0.58 15 4.53 18.8 526 164 43.3 0.60 15 4.64 19.3 543 169 44.6 0.63 14 4.68 19.5 548 170 Amps = outdoor unit amps (comp.+fan) kW = Total system power 42.8 0.74 21 4.42 17.9 481 160 46.4 0.77 21 4.53 18.4 496 165 47.8 0.81 20 4.56 18.5 501 166 71 43.1 0.6 16 4.4 17.7 476.3 158.2 46.7 0.6 16 4.5 18.2 491.1 163.1 48.1 0.6 15 4.5 18.4 496.0 164.7 115ºF Cooling Data — ANX130481A* / CA*F4860*6D*+EEP (cont.) 19 20 www.amana-hac.com 55.1 0.79 23 4.06 15.4 262 106 55.1 0.79 23 4.06 15.4 262 106 57.1 0.84 20 4.13 15.7 267 109 MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2250 kW Amps HI PR LO PR 59 54.2 0.69 20 4.03 15.2 259 105 54.2 0.69 20 4.03 15.2 259 105 56.1 0.74 17 4.09 15.5 264 107 MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2250 kW Amps HI PR LO PR Airflow 63 56.8 0.71 21 4.15 15.8 282 113 56.8 0.71 21 4.15 15.8 282 113 58.8 0.75 18 4.21 16.1 287 115 56.2 0.58 17 4.11 15.6 279 112 56.2 0.58 17 4.11 15.6 279 112 58.2 0.62 15 4.18 15.9 284 114 67 61.5 0.53 17 4.27 16.3 297 124 61.5 0.53 17 4.27 16.3 297 124 63.6 0.57 15 4.34 16.6 303 126 61.6 0.40 13 4.24 16.1 294 122 61.6 0.40 13 4.24 16.1 294 122 63.7 0.43 11 4.31 16.4 300 125 66.0 0.34 12 4.41 16.9 310 132 66.0 0.34 12 4.41 16.9 310 132 68.3 0.36 10 4.48 17.2 316 134 - 71 53.9 0.82 23 4.37 16.7 294 112 53.9 0.82 23 4.37 16.7 294 112 55.8 0.87 20 4.44 17.0 299 115 59 53.0 0.72 20 4.33 16.5 291 111 53.0 0.72 20 4.33 16.5 291 111 54.8 0.76 17 4.40 16.8 296 114 63 55.5 0.73 21 4.46 17.1 316 120 55.5 0.73 21 4.46 17.1 316 120 57.4 0.78 18 4.53 17.4 322 122 54.9 0.60 17 4.42 16.9 313 118 54.9 0.60 17 4.42 16.9 313 118 56.8 0.64 15 4.49 17.2 319 121 67 60.0 0.55 17 4.60 17.6 334 131 60.0 0.55 17 4.60 17.6 334 131 62.1 0.59 15 4.67 18.0 340 133 60.1 0.42 13 4.56 17.5 330 129 60.1 0.42 13 4.56 17.5 330 129 62.3 0.44 11 4.63 17.8 337 132 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 64.4 0.36 12 4.75 18.3 348 139 64.4 0.36 12 4.75 18.3 348 139 66.7 0.38 10 4.82 18.7 355 142 - 71 63 54.1 0.75 21 4.74 18.6 359 124 54.1 0.75 21 4.74 18.6 359 124 56.0 0.80 18 4.81 18.9 366 127 53.6 0.62 17 4.70 18.4 356 123 53.6 0.62 17 4.70 18.4 356 123 55.5 0.65 15 4.77 18.8 363 126 67 58.6 0.57 17 4.89 19.2 379 136 58.6 0.57 17 4.89 19.2 379 136 60.7 0.60 15 4.97 19.6 387 138 58.7 0.43 13 4.85 19.0 376 134 58.7 0.43 13 4.85 19.0 376 134 60.8 0.45 11 4.92 19.4 383 137 62.9 0.36 12 5.04 20.0 396 145 62.9 0.36 12 5.04 20.0 396 145 65.1 0.39 10 5.13 20.3 404 147 - 71 59 51.3 0.86 23 4.87 19.4 380 123 51.3 0.86 23 4.87 19.4 380 123 53.1 0.92 20 4.95 19.8 388 125 50.4 0.76 20 4.83 19.2 376 122 50.4 0.76 20 4.83 19.2 376 122 52.2 0.81 17 4.91 19.6 384 124 Shaded area reflects ACCA (TVA) conditions 52.6 0.84 23 4.64 18.1 334 117 52.6 0.84 23 4.64 18.1 334 117 54.4 0.89 20 4.71 18.5 341 119 59 51.7 0.74 20 4.60 18.0 331 116 51.7 0.74 20 4.60 18.0 331 116 53.5 0.78 17 4.67 18.3 337 118 63 52.8 0.77 21 4.98 19.9 409 131 52.8 0.77 21 4.98 19.9 409 131 54.7 0.82 18 5.06 20.3 417 133 52.3 0.64 17 4.94 19.7 405 129 52.3 0.64 17 4.94 19.7 405 129 54.1 0.68 15 5.02 20.1 413 132 67 57.2 0.59 18 5.14 20.6 432 143 57.2 0.59 18 5.14 20.6 432 143 59.2 0.62 15 5.22 21.0 441 145 57.3 0.44 13 5.10 20.4 428 141 57.3 0.44 13 5.10 20.4 428 141 59.3 0.47 11 5.18 20.8 436 144 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 61.4 0.38 12 5.31 21.4 451 152 61.4 0.38 12 5.31 21.4 451 152 63.5 0.40 10 5.40 21.8 460 155 - 71 48.7 0.90 23 5.07 20.7 428 129 48.7 0.90 23 5.07 20.7 428 129 50.4 0.95 20 5.16 21.1 436 131 59 47.9 0.79 20 5.03 20.5 423 127 47.9 0.79 20 5.03 20.5 423 127 49.6 0.84 17 5.12 20.9 432 130 50.2 0.80 21 5.19 21.2 460 137 50.2 0.80 21 5.19 21.2 460 137 51.9 0.85 18 5.27 21.6 470 140 63 49.7 0.66 17 5.14 21.0 456 135 49.7 0.66 17 5.14 21.0 456 135 51.4 0.70 15 5.23 21.4 465 138 54.3 0.61 17 5.35 21.9 486 149 54.3 0.61 17 5.35 21.9 486 149 56.2 0.65 15 5.44 22.3 496 152 67 54.4 0.46 13 5.31 21.7 481 148 54.4 0.46 13 5.31 21.7 481 148 56.3 0.49 11 5.40 22.1 491 151 105ºF 45.1 0.91 21 5.25 21.9 473 133 45.1 0.91 21 5.25 21.9 473 133 46.7 0.96 18 5.34 22.4 482 136 59 44.4 0.80 19 5.21 21.7 468 132 44.4 0.80 19 5.21 21.7 468 132 45.9 0.85 16 5.29 22.1 477 134 46.5 0.81 20 5.36 22.5 509 142 46.5 0.81 20 5.36 22.5 509 142 48.1 0.86 17 5.45 22.9 519 144 63 46.0 0.66 16 5.32 22.3 504 140 46.0 0.66 16 5.32 22.3 504 140 47.6 0.71 14 5.41 22.7 514 143 50.3 0.61 16 5.54 23.3 537 155 50.3 0.61 16 5.54 23.3 537 155 52.1 0.65 14 5.63 23.7 548 158 67 50.4 0.46 12 5.49 23.0 532 153 50.4 0.46 12 5.49 23.0 532 153 52.2 0.49 10 5.58 23.5 542 156 54.0 0.39 11 5.72 24.2 560 165 54.0 0.39 11 5.72 24.2 560 165 55.9 0.42 10 5.82 24.6 571 168 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 58.3 0.39 12 5.53 22.8 507 159 58.3 0.39 12 5.53 22.8 507 159 60.3 0.42 10 5.62 23.2 517 162 - 71 115ºF Cooling Data — ANX130601A* / CA*F4961*6D*+EEP SS-ANX13 SS-ANX13 www.amana-hac.com 57.1 0.91 27 4.13 15.7 267 109 57.1 0.91 27 4.13 15.7 267 109 59.1 0.96 23 4.19 16.0 272 111 MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 2250 kW Amps HI PR LO PR 59 56.1 0.86 25 4.09 15.5 264 107 56.1 0.86 25 4.09 15.5 264 107 58.1 0.92 22 4.16 15.8 270 110 MBh S/T ∆T kW 1750 Amps HI PR LO PR MBh S/T ∆T kW 1750 Amps HI PR LO PR MBh S/T ∆T 2250 kW Amps HI PR LO PR Airflow 63 58.2 0.87 27 4.21 16.1 287 116 58.2 0.87 27 4.21 16.1 287 116 60.3 0.93 23 4.28 16.4 293 118 57.4 0.81 24 4.18 15.9 284 114 57.4 0.81 24 4.18 15.9 284 114 59.4 0.86 21 4.24 16.2 290 117 67 61.0 0.79 25 4.34 16.6 303 126 61.0 0.79 25 4.34 16.6 303 126 63.1 0.84 22 4.41 16.9 309 129 61.3 0.66 21 4.31 16.4 300 125 61.3 0.66 21 4.31 16.4 300 125 63.4 0.70 18 4.38 16.7 306 127 65.0 0.64 22 4.48 17.2 316 134 65.0 0.64 22 4.48 17.2 316 134 67.3 0.68 19 4.55 17.5 323 137 71 65.5 0.5 17 4.4 17.1 313.2 133.0 65.5 0.5 17 4.4 17.1 313.2 133.0 67.8 0.5 15 4.5 17.4 319.5 135.6 55.8 0.94 28 4.44 17.0 300 115 55.8 0.94 28 4.44 17.0 300 115 57.7 1.00 24 4.51 17.3 305 117 59 54.8 0.90 26 4.40 16.8 297 114 54.8 0.90 26 4.40 16.8 297 114 56.7 0.95 22 4.47 17.1 302 116 63 56.9 0.91 27 4.53 17.4 322 122 56.9 0.91 27 4.53 17.4 322 122 58.8 0.96 23 4.60 17.7 329 124 56.0 0.84 25 4.49 17.2 319 121 56.0 0.84 25 4.49 17.2 319 121 58.0 0.89 21 4.57 17.6 326 123 67 59.6 0.82 26 4.67 18.0 340 133 59.6 0.82 26 4.67 18.0 340 133 61.6 0.87 22 4.75 18.3 347 136 59.9 0.68 22 4.64 17.8 337 132 59.9 0.68 22 4.64 17.8 337 132 61.9 0.73 18 4.71 18.1 344 135 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 63.5 0.66 22 4.82 18.7 355 142 63.5 0.66 22 4.82 18.7 355 142 65.8 0.71 19 4.90 19.0 362 145 71 64.0 0.51 17 4.78 18.5 351 140 64.0 0.51 17 4.78 18.5 351 140 66.2 0.54 15 4.86 18.8 358 143 63 55.5 0.93 27 4.81 18.9 367 127 55.5 0.93 27 4.81 18.9 367 127 57.4 0.99 23 4.89 19.3 374 129 54.7 0.86 25 4.77 18.8 363 126 54.7 0.86 25 4.77 18.8 363 126 56.6 0.92 21 4.85 19.1 370 128 67 58.1 0.84 26 4.97 19.6 387 138 58.1 0.84 26 4.97 19.6 387 138 60.2 0.89 22 5.05 19.9 395 141 58.4 0.70 22 4.93 19.4 383 137 58.4 0.70 22 4.93 19.4 383 137 60.5 0.75 18 5.01 19.8 391 140 71 62.0 0.68 22 5.13 20.3 404 147 62.0 0.68 22 5.13 20.3 404 147 64.2 0.72 19 5.21 20.7 412 150 62.5 0.5 17 5.1 20.1 399.7 146.0 62.5 0.5 17 5.1 20.1 399.7 146.0 64.6 0.6 15 5.2 20.5 407.7 148.9 Shaded area reflects AHRI conditions 54.5 0.96 28 4.71 18.5 341 119 54.5 0.96 28 4.71 18.5 341 119 56.4 1.00 23 4.79 18.8 347 122 59 53.5 0.92 26 4.67 18.3 337 118 53.5 0.92 26 4.67 18.3 337 118 55.4 1.00 23 4.75 18.6 344 120 59 53.1 0.99 28 4.95 19.8 388 125 53.1 0.99 28 4.95 19.8 388 125 55.0 1.00 22 5.03 20.1 396 128 52.2 0.95 26 4.91 19.6 384 124 52.2 0.95 26 4.91 19.6 384 124 54.0 1.00 22 4.99 20.0 392 126 63 54.2 0.96 27 5.06 20.3 417 133 54.2 0.96 27 5.06 20.3 417 133 56.0 1.00 23 5.14 20.7 426 136 53.4 0.89 25 5.02 20.1 413 132 53.4 0.89 25 5.02 20.1 413 132 55.2 0.95 21 5.10 20.5 422 135 67 56.7 0.87 26 5.22 21.0 441 145 56.7 0.87 26 5.22 21.0 441 145 58.7 0.92 22 5.31 21.4 450 148 57.0 0.72 22 5.18 20.8 437 144 57.0 0.72 22 5.18 20.8 437 144 59.0 0.77 19 5.27 21.2 445 147 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 60.5 0.70 22 5.40 21.8 460 155 60.5 0.70 22 5.40 21.8 460 155 62.6 0.75 19 5.49 22.2 469 158 71 60.9 0.54 17 5.35 21.6 455 153 60.9 0.54 17 5.35 21.6 455 153 63.1 0.58 15 5.44 22.0 464 156 50.5 1.00 27 5.16 21.1 436 131 50.5 1.00 27 5.16 21.1 436 131 52.2 1.00 21 5.24 21.5 445 134 59 49.6 0.98 26 5.12 20.9 432 130 49.6 0.98 26 5.12 20.9 432 130 51.3 1.00 21 5.20 21.3 441 133 51.4 1.00 27 5.27 21.6 470 140 51.4 1.00 27 5.27 21.6 470 140 53.2 1.00 22 5.36 22.0 479 142 63 50.7 0.92 25 5.23 21.4 465 138 50.7 0.92 25 5.23 21.4 465 138 52.5 1.00 21 5.32 21.8 474 141 53.9 0.90 25 5.44 22.3 496 152 53.9 0.90 25 5.44 22.3 496 152 55.8 0.96 22 5.53 22.8 506 155 67 54.2 0.75 21 5.40 22.1 491 151 54.2 0.75 21 5.40 22.1 491 151 56.0 0.80 18 5.49 22.6 501 154 105ºF 46.7 1.00 25 5.34 22.4 482 136 46.7 1.00 25 5.34 22.4 482 136 48.4 1.00 20 5.42 22.8 492 138 59 45.9 0.99 24 5.29 22.2 477 134 45.9 0.99 24 5.29 22.2 477 134 47.6 1.00 19 5.38 22.6 487 137 47.7 1.00 25 5.45 22.9 519 144 47.7 1.00 25 5.45 22.9 519 144 49.3 1.00 20 5.55 23.4 529 147 63 46.9 0.93 23 5.41 22.7 514 143 46.9 0.93 23 5.41 22.7 514 143 48.6 1.00 20 5.50 23.1 524 146 49.9 0.91 24 5.63 23.7 548 158 49.9 0.91 24 5.63 23.7 548 158 51.7 0.96 20 5.73 24.2 559 161 67 50.2 0.76 20 5.59 23.5 543 156 50.2 0.76 20 5.59 23.5 543 156 51.9 0.81 17 5.68 23.9 553 159 53.2 0.74 21 5.82 24.6 572 168 53.2 0.74 21 5.82 24.6 572 168 55.1 0.78 18 5.92 25.1 583 171 71 53.6 0.57 16 5.77 24.4 566 166 53.6 0.57 16 5.77 24.4 566 166 55.5 0.60 14 5.87 24.9 577 170 Amps = outdoor unit amps (comp.+fan) kW = Total system power 57.5 0.73 22 5.63 23.2 517 162 57.5 0.73 22 5.63 23.2 517 162 59.5 0.77 19 5.72 23.7 528 166 71 57.9 0.6 17 5.6 23.0 512.2 160.7 57.9 0.6 17 5.6 23.0 512.2 160.7 59.9 0.6 15 5.7 23.4 522.4 163.9 115ºF Cooling Data — ANX130601A* / CA*F4961*6D*+EEP (cont.) 21 22 www.amana-hac.com 56.3 0.78 23 4.03 15.7 252 101 54.7 0.74 25 4.00 15.5 249 100 56.6 0.79 18 4.06 15.8 254 102 MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 2250 kW Amps HI PR LO PR 59 55.4 0.68 20 4.00 15.5 249 100 53.8 0.65 21 3.97 15.4 247 99 55.6 0.69 16 4.03 15.7 252 101 MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 2250 kW Amps HI PR LO PR Airflow 63 58.0 0.69 21 4.12 16.1 271 107 56.3 0.66 23 4.09 15.9 268 106 58.3 0.70 17 4.15 16.2 274 108 57.4 0.57 17 4.08 15.9 268 106 55.7 0.54 19 4.05 15.8 266 105 57.7 0.58 14 4.12 16.1 271 107 67 62.7 0.52 17 4.25 16.6 286 117 60.9 0.50 19 4.21 16.5 283 116 63.1 0.53 14 4.28 16.8 289 118 62.9 0.39 13 4.21 16.4 283 116 61.0 0.38 14 4.18 16.3 281 115 63.2 0.40 10 4.25 16.6 286 117 67.3 0.34 12 4.39 17.2 299 124 65.4 0.32 13 4.35 17.1 296 123 67.7 0.34 9 4.42 17.4 302 126 - 71 55.0 0.80 23 4.34 17.0 283 106 53.4 0.77 25 4.31 16.8 280 105 55.3 0.81 18 4.38 17.1 285 107 59 54.1 0.71 20 4.31 16.8 280 105 52.5 0.67 22 4.27 16.7 277 104 54.3 0.72 16 4.34 17.0 283 106 63 56.6 0.72 21 4.44 17.4 304 113 55.0 0.69 23 4.40 17.2 301 112 56.9 0.73 17 4.47 17.6 307 114 56.1 0.59 17 4.40 17.2 301 112 54.4 0.56 19 4.37 17.1 298 111 56.3 0.60 14 4.44 17.4 304 113 67 61.3 0.54 18 4.58 18.0 321 123 59.5 0.52 19 4.54 17.8 318 122 61.6 0.55 14 4.62 18.2 324 125 61.4 0.41 13 4.54 17.8 318 122 59.6 0.39 14 4.51 17.7 315 121 61.7 0.41 10 4.58 18.0 321 123 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 65.8 0.35 12 4.73 18.7 335 131 63.9 0.33 13 4.69 18.5 332 130 66.1 0.35 10 4.77 18.9 338 133 - 71 63 55.3 0.74 21 4.72 19.0 346 118 53.7 0.70 23 4.68 18.8 343 116 55.5 0.75 17 4.76 19.1 349 119 54.7 0.61 17 4.68 18.8 342 116 53.1 0.58 19 4.64 18.6 339 115 55.0 0.61 14 4.72 19.0 346 118 67 59.8 0.56 18 4.88 19.6 365 128 58.1 0.53 19 4.84 19.4 362 127 60.1 0.57 14 4.92 19.8 369 130 59.9 0.42 13 4.84 19.4 362 127 58.2 0.40 14 4.80 19.2 358 126 60.2 0.43 10 4.88 19.6 365 128 64.2 0.36 12 5.04 20.4 381 137 62.3 0.34 13 5.00 20.2 377 135 64.5 0.36 10 5.08 20.6 385 138 - 71 59 52.4 0.85 23 4.86 19.8 366 116 50.9 0.81 25 4.82 19.6 363 115 52.6 0.86 19 4.90 20.0 370 117 51.5 0.75 20 4.82 19.6 362 115 50.0 0.71 22 4.78 19.4 359 114 51.8 0.76 16 4.86 19.8 366 116 Shaded area reflects ACCA (TVA) conditions 53.7 0.82 23 4.62 18.5 321 110 52.1 0.79 25 4.58 18.3 318 109 53.9 0.84 18 4.66 18.7 325 112 59 52.8 0.72 20 4.58 18.3 318 109 51.3 0.69 22 4.54 18.1 315 108 53.0 0.73 16 4.62 18.5 321 110 63 53.9 0.76 22 4.97 20.3 394 123 52.4 0.73 23 4.93 20.1 390 122 54.2 0.77 17 5.01 20.5 398 125 53.4 0.62 18 4.93 20.1 390 122 51.8 0.60 19 4.89 19.9 386 121 53.6 0.63 14 4.97 20.3 394 123 67 58.4 0.58 18 5.14 21.0 416 135 56.7 0.55 19 5.09 20.8 412 133 58.7 0.58 14 5.18 21.2 420 136 58.5 0.43 13 5.09 20.8 412 133 56.8 0.41 14 5.05 20.6 408 132 58.8 0.44 11 5.13 21.0 416 135 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 62.6 0.37 12 5.31 21.8 434 144 60.8 0.35 13 5.26 21.6 430 142 63.0 0.38 10 5.35 22.0 438 145 - 71 49.8 0.88 23 5.07 21.1 412 122 48.3 0.84 25 5.03 20.9 408 120 50.0 0.89 18 5.11 21.3 416 123 59 48.9 0.78 20 5.03 20.9 408 120 47.5 0.74 22 4.99 20.7 404 119 49.2 0.79 16 5.07 21.1 412 122 51.2 0.79 21 5.18 21.6 443 129 49.7 0.75 23 5.14 21.4 439 128 51.5 0.80 17 5.23 21.8 448 131 63 50.7 0.65 17 5.14 21.4 439 128 49.2 0.62 19 5.10 21.2 434 127 51.0 0.66 14 5.18 21.6 443 129 55.5 0.60 17 5.36 22.4 468 141 53.8 0.57 19 5.31 22.2 463 140 55.7 0.61 14 5.40 22.6 473 143 67 55.6 0.45 13 5.31 22.2 463 140 53.9 0.43 14 5.27 22.0 459 138 55.8 0.46 10 5.36 22.4 468 141 105ºF 46.1 0.89 22 5.25 22.4 455 126 44.7 0.85 23 5.20 22.2 451 125 46.3 0.90 17 5.29 22.6 460 127 59 45.3 0.78 19 5.20 22.2 451 125 44.0 0.75 20 5.16 22.0 446 123 45.5 0.79 15 5.25 22.4 455 126 47.5 0.80 20 5.37 23.0 490 134 46.1 0.76 21 5.32 22.7 485 133 47.7 0.81 16 5.41 23.2 495 135 63 47.0 0.65 16 5.32 22.7 485 132 45.6 0.62 17 5.28 22.5 480 131 47.2 0.66 13 5.37 23.0 490 134 51.4 0.60 16 5.55 23.8 517 146 49.9 0.57 18 5.50 23.5 512 145 51.6 0.61 13 5.59 24.0 522 148 67 51.5 0.45 12 5.50 23.5 512 145 50.0 0.43 13 5.45 23.3 507 143 51.7 0.46 10 5.55 23.7 517 146 55.1 0.39 11 5.74 24.7 539 156 53.5 0.37 12 5.69 24.4 534 154 55.4 0.39 9 5.79 24.9 545 157 - 71 Amps = outdoor unit amps (comp.+fan) kW = Total system power 59.5 0.38 12 5.54 23.3 488 150 57.8 0.37 13 5.49 23.0 483 149 59.8 0.39 10 5.59 23.5 493 152 - 71 115ºF Cooling Data — ANX130611A* / CA*F4961*6D*+EEP SS-ANX13 SS-ANX13 www.amana-hac.com 58.3 0.89 27 4.10 16.0 257 103 56.6 0.85 29 4.06 15.8 254 102 58.6 0.90 22 4.13 16.1 260 104 MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 2250 kW Amps HI PR LO PR 59 57.3 0.85 26 4.06 15.8 254 102 55.6 0.81 28 4.03 15.7 252 101 57.6 0.86 20 4.10 16.0 257 103 MBh S/T ∆T 1750 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 2250 kW Amps HI PR LO PR Airflow 63 59.4 0.86 27 4.19 16.4 277 109 57.7 0.82 29 4.15 16.2 274 108 59.7 0.87 21 4.22 16.5 279 110 58.6 0.80 25 4.15 16.2 274 108 56.9 0.76 26 4.12 16.1 271 107 58.8 0.81 19 4.18 16.4 277 109 67 62.2 0.78 25 4.32 16.9 292 119 60.4 0.74 27 4.28 16.8 289 118 62.5 0.79 20 4.35 17.1 295 120 62.6 0.65 21 4.28 16.8 289 118 60.7 0.62 23 4.25 16.6 286 117 62.9 0.66 17 4.32 16.9 292 119 66.4 0.63 22 4.46 17.6 305 127 64.5 0.60 24 4.42 17.4 302 126 66.7 0.64 17 4.49 17.7 308 128 71 66.9 0.5 17 4.4 17.4 301.6 125.7 64.9 0.5 18 4.4 17.2 298.6 124.5 67.2 0.5 14 4.5 17.6 304.6 127.0 56.9 0.92 28 4.42 17.3 288 108 55.3 0.88 30 4.38 17.1 286 107 57.2 0.94 22 4.45 17.5 291 110 59 56.0 0.88 26 4.38 17.1 286 107 54.3 0.84 28 4.34 17.0 283 106 56.2 0.89 21 4.42 17.3 288 108 63 58.1 0.89 27 4.51 17.7 310 115 56.4 0.85 29 4.48 17.6 307 114 58.3 0.90 22 4.55 17.9 313 117 57.2 0.83 25 4.48 17.6 307 114 55.5 0.79 27 4.44 17.4 304 113 57.5 0.84 20 4.51 17.7 310 115 67 60.8 0.80 26 4.66 18.3 328 126 59.0 0.77 28 4.62 18.2 324 125 61.1 0.82 20 4.70 18.5 331 127 61.1 0.67 22 4.62 18.2 324 125 59.3 0.64 23 4.58 18.0 321 123 61.4 0.68 17 4.66 18.3 328 126 75ºF IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 64.9 0.65 22 4.81 19.0 342 134 63.0 0.62 24 4.77 18.9 338 133 65.2 0.66 18 4.85 19.2 345 135 71 65.3 0.50 17 4.77 18.9 338 133 63.4 0.48 19 4.73 18.7 335 132 65.6 0.51 14 4.81 19.0 342 134 63 56.7 0.91 27 4.80 19.3 353 120 55.0 0.87 29 4.76 19.1 349 119 56.9 0.93 22 4.84 19.5 356 121 55.8 0.85 25 4.76 19.1 349 119 54.2 0.81 27 4.72 19.0 346 118 56.1 0.86 20 4.80 19.3 353 120 67 59.4 0.82 26 4.96 20.0 373 131 57.6 0.79 28 4.92 19.8 369 130 59.6 0.84 20 5.00 20.2 376 132 59.6 0.69 22 4.92 19.8 369 130 57.9 0.66 23 4.88 19.6 365 128 59.9 0.70 17 4.96 20.0 373 131 71 63.3 0.67 22 5.12 20.7 389 139 61.5 0.64 24 5.08 20.6 385 138 63.6 0.68 18 5.17 20.9 393 141 63.8 0.5 17 5.1 20.6 384.9 138.0 61.9 0.5 19 5.0 20.4 381.0 136.7 64.1 0.5 14 5.1 20.7 388.7 139.4 Shaded area reflects AHRI conditions 55.6 0.95 28 4.70 18.8 328 113 54.0 0.90 30 4.66 18.7 325 112 55.9 0.96 22 4.74 19.0 331 114 59 54.6 0.90 26 4.66 18.7 325 112 53.0 0.86 28 4.62 18.5 321 110 54.9 0.92 21 4.70 18.8 328 113 59 54.2 0.98 28 4.95 20.2 374 118 52.7 0.93 30 4.90 20.0 370 117 54.5 0.99 22 4.99 20.4 377 120 53.3 0.93 26 4.90 20.0 370 117 51.8 0.89 28 4.86 19.8 366 116 53.6 0.95 21 4.94 20.2 373 118 63 55.3 0.94 27 5.06 20.7 402 126 53.7 0.90 30 5.01 20.5 398 125 55.6 0.96 22 5.10 20.9 406 127 54.5 0.87 25 5.01 20.5 398 125 52.9 0.83 27 4.97 20.3 394 123 54.7 0.89 20 5.06 20.7 402 126 67 57.9 0.85 26 5.22 21.4 424 138 56.2 0.81 28 5.18 21.2 420 136 58.2 0.86 21 5.27 21.6 429 139 58.2 0.71 22 5.18 21.2 420 136 56.5 0.68 24 5.14 21.0 416 135 58.5 0.72 17 5.22 21.4 424 137 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 61.8 0.69 22 5.40 22.2 443 146 60.0 0.66 24 5.35 22.0 438 145 62.1 0.70 18 5.45 22.4 447 148 71 62.2 0.53 17 5.35 22.0 438 145 60.4 0.51 19 5.31 21.8 434 144 62.5 0.54 14 5.40 22.2 443 146 51.5 1.00 27 5.16 21.5 420 124 50.0 0.97 30 5.11 21.3 416 123 51.8 1.00 21 5.20 21.7 424 125 59 50.6 0.97 26 5.11 21.3 416 123 49.2 0.92 28 5.07 21.1 412 122 50.9 1.00 21 5.16 21.5 420 124 52.5 0.98 27 5.27 22.1 452 132 51.0 0.93 29 5.23 21.8 448 131 52.8 0.99 21 5.32 22.3 457 133 63 51.7 0.91 25 5.23 21.8 448 131 50.2 0.87 27 5.18 21.6 443 129 52.0 0.92 20 5.27 22.1 452 132 55.0 0.88 26 5.45 22.8 478 144 53.4 0.84 28 5.40 22.6 473 143 55.3 0.90 20 5.49 23.0 482 146 67 55.3 0.74 21 5.40 22.6 473 143 53.7 0.70 23 5.36 22.4 468 141 55.6 0.75 17 5.45 22.8 477 144 105ºF 47.7 1.00 25 5.34 22.8 464 128 46.3 0.98 28 5.29 22.6 460 127 48.0 1.00 20 5.38 23.0 469 130 59 46.9 1.00 25 5.29 22.6 460 127 45.5 0.93 26 5.25 22.4 455 126 47.1 1.00 19 5.34 22.8 464 128 48.7 0.99 25 5.46 23.4 500 137 47.2 0.94 27 5.41 23.2 495 135 48.9 1.00 20 5.51 23.6 505 138 63 47.9 0.92 23 5.41 23.2 495 135 46.5 0.87 25 5.37 23.0 490 134 48.2 0.93 18 5.46 23.4 500 137 51.0 0.89 24 5.64 24.2 528 149 49.5 0.85 26 5.59 24.0 522 148 51.2 0.90 19 5.69 24.4 533 151 67 51.2 0.75 20 5.59 24.0 522 148 49.7 0.71 22 5.55 23.8 517 146 51.5 0.76 16 5.64 24.2 528 149 54.4 0.72 21 5.84 25.2 550 159 52.8 0.69 22 5.79 24.9 545 157 54.6 0.73 16 5.89 25.4 556 160 71 54.7 0.56 16 5.79 24.9 545 157 53.2 0.53 17 5.74 24.7 539 156 55.0 0.56 13 5.84 25.2 550 159 Amps = outdoor unit amps (comp.+fan) kW = Total system power 58.7 0.72 22 5.63 23.7 498 153 57.0 0.68 24 5.59 23.5 493 152 59.0 0.73 18 5.68 23.9 503 155 71 59.1 0.6 17 5.6 23.5 493.1 152.0 57.4 0.5 19 5.5 23.3 488.2 150.5 59.4 0.6 14 5.6 23.7 498.0 153.5 115ºF Cooling Data — ANX130611A* / CA*F4961*6D*+EEP (cont.) 23 24 H W D 26 29 29 ANX130361A* ANX130421A* ANX130481A* www.amana-hac.com 35½ 29 29 29 26 26 26 26 26 D" Dimensions H" 38¼ 40 36¼ 36¼ 27½ 32½ 27½ 27½ 27½ ANX13 Goodman Company, L.P. 29 26 ANX130301B* 35½ 26 ANX130301A* ANX130611A* 26 ANX130241** ANX130601A* 26 W" ANX130181A* Model Dimensions SS-ANX13 SS-ANX13 www.amana-hac.com L2 L1 1 SR IO CM AUX MAIN BL BK YL RD IO BK Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. BK BR PU ALTERNATE DOUBLE POLE CONTACTOR T2 T1 YL 2 5 BK CONTROL BOX C AUX S YL/PK C L2 T2 LPS YL PU L1 T1 ⚠ Warning R YL COMP MAIN RD BL BK BK BK SA (IF USED) NOTE 2 RD YL H C RD F RCCF BL YL LVJB NOTE 1 C T1 C IO X AU SR S LPS CM IO COMP M AI N R 5 2 C M AI N SC C (IF USED) SA RCCF X AU F H 1 OUTDOOR POWER SUPPLY SEE RATING PLATE T2 C CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. ⚡ L2 0140R00331-A COMPONENT CODE Y C C --------------- CONTACTOR NOTE 1 CSM -------- CORESENSE MODULE CM ------------ OUTDOOR FAN MOTOR NOTES: COMP -------- COMPRESSOR 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR IO -------------- INTERNAL OVERLOAD THERMOSTAT. LVJB ---------- LOW VOLTAGE JUNCTION BOX 2) START ASSIST FACTORY RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN EQUIPPED WHEN REQUIRED. SA ------------- START ASSIST 3) USE COPPER CONDUCTORS ONLY. SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) USE N.E.C. SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) CLASS 2 WIRE LPS ------------ LOW PRESSURE SWITCH FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE L1 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. YL/PK EQUIPMENT GROUND SEE NOTE 3 RD RD RD BR YL RD RD SC C BL LVJB COLOR CODE BK --------------- BLACK BL --------------- BLUE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL --------------- YELLOW YL/PK ---------- YELLOW/PINK STRIPE Y ALTERNATE DOUBLE POLE CONTACTOR ONLY YL/PK Wiring Diagram — ANX130181A*-301A* 25 26 www.amana-hac.com YL T2 L2 T1 L1 1 SR BL IO CM AUX MAIN ALTERNATE DOUBLE POLE CONTACTOR 2 5 BK BK BR PU BK IO C MAIN R AUX BL S BL/PK COMP BL/PK BL/PK Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. YL RD CONTROL BOX L1 C RD RCCF F HERM RD SA (IF USED) NOTE 2 BR RD RD YL YL YL BL YL EQUIPMENT GROUND RD PU RD RD ⚠ Warning C L2 T2 BK HPS BK T1 BK SC C BL NOTE 1 L1 C M AI N X AU HPS CM IO IO Y SR S AI N R COMP X AU M 5 C 2 F H 1 ⚡ USE N.E.C. CLASS 2 WIRE SC C C (IF USED) SA RCCF OUTDOOR POWER SUPPLY SEE RATING PLATE T2 0140R00258-B NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR THERMOSTAT 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTORS ONLY. T1 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. COMPONENT CODE C --------------- CONTACTOR CM ------------ OUTDOOR FAN MOTOR COMP -------- COMPRESSOR HPS ----------- HIGH PRESSURE SWITCH IO -------------- INTERNAL OVERLOAD LVJB ---------- LOW VOLTAGE JUNCTION BOX RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE COLOR CODE BK --------------- BLACK BL --------------- BLUE BL/PK ---------- BLUE/PINK STRIPE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL ---------------- YELLOW Y BL/PK ALTERNATE DOUBLE POLE CONTACTOR ONLY LVJB C L2 Wiring Diagram — ANX130181B*-0301B* SS-ANX13 SS-ANX13 www.amana-hac.com YL T2 L2 T1 L1 1 SR BL IO CM AUX MAIN ALTERNATE DOUBLE POLE CONTACTOR 2 5 BK YL BK C R AUX MAIN BL YL COMP Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. BK BR PU RD CONTROL BOX L1 C L2 T2 BK C RD F RCCF HERM RD SA (IF USED) NOTE 2 BR RD RD YL YL YL BL YL L1 C T1 C CM IO IO CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. COMPONENT CODE C --------------- CONTACTOR CM ------------ OUTDOOR FAN MOTOR COMP -------- COMPRESSOR IO -------------- INTERNAL OVERLOAD LVJB ---------- LOW VOLTAGE JUNCTION BOX RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN SA ------------- START ASSIST SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE NOTE 1 M AI N X AU S AI N R C 2 F 1 C SA C (IF USED) RCCF SC H T2 C ⚡ 0140R00015P-A USE N.E.C. CLASS 2 WIRE NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR THERMOSTAT 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. Y SR COMP X AU M 5 OUTDOOR POWER SUPPLY SEE RATING PLATE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. EQUIPMENT GROUND USE COPPER CONDUCTORS ONLY RD PU RD RD ⚠ Warning S BK T1 BK SC C Y COLOR CODE BK --------------- BLACK BL --------------- BLUE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL ---------------- YELLOW BL YL ALTERNATE DOUBLE POLE CONTACTOR ONLY LVJB L2 Wiring Diagram — ANX130361**-0611** 27 Accessories Model Description ANX13 018** ABK-20 Anchor Bracket Kit ^ ABK-21 Anchor Bracket Kit ^ X ANX13 024** ANX13 030** ANX13 036** ANX13 042** ANX13 048** ANX13 060** ANX13 061** X X X X X X X X X X X X X X X ASC-01 Anti-Short Cycle Kit X X X X CSR-U-1 Hard-start Kit X X X X CSR-U-2 Hard-start Kit CSR-U-3 Hard-start Kit X X X FSK01A¹ Freeze Protection Kit X X X X X X X X X X X X LSK02A² Liquid Line Solenoid Kit X X X X 0130R00000S Low-Pressure Switch Kit X X X X X X X X LAKT01A Low-Ambient Kit X X X X X X X X TX2N4A² TXV Kit X X TX3N4² TXV Kit X X TX5N4² TXV Kit X X X X ^ ¹ ² Contains 20 brackets; four brackets needed to anchor unit to pad Installed on indoor coil Field-installed, non-bleed, expansion valve kit — Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. All AHRI system ratings are accessible in the System Configurator tool via PartnerLink. 28 www.amana-hac.com SS-ANX13
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project