Rosslare AYC-E60 Backlit goPROX® & PIN Reader – Convertible Series Manual
Show HTML Add to My manuals65 Pages
advertisement
AYC-E60
Backlit goPROX & PIN Reader –
Convertible with Genuine HID
Technology™
Installation and User Manual
AYC-E60B AYC-E60N
Copyright © 2019 by Rosslare. All rights reserved.
This manual and the information contained herein are proprietary to
ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN
THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT
LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE,
REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT
EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
Table of Contents
Table of Contents
Introduction ........................................................................... 9
Box Content ............................................................................... 9
Ancillary Equipment ................................................................. 10
Installation .......................................................................... 11
Mounting .................................................................................. 11
Wiring ....................................................................................... 12
Wiring the Unit as a Reader .............................................................12
Wiring the Unit as a Controller.........................................................13
Reader Operation ................................................................ 16
General ..................................................................................... 16
Programming as a Reader ....................................................... 17
Entering Programming Mode ..........................................................18
Exiting Programming Mode ............................................................19
Selecting Keypad Transmission Format ........................................19
Selecting HID Prox Card Transmission Format ............................24
Selecting Rosslare Proximity Card Transmission Format ...........25
Changing the Programming Code ..................................................27
Changing the Facility Code..............................................................27
Setting the Backlight Behavior ........................................................28
Setting the Credential Format .........................................................29
Return to Factory Default Settings .................................................29
Replacing a Lost Programming Code ............................................30
Controller Operation ............................................................ 31
Normal, Secure, and Master Users .......................................... 31
AYC-E60 Installation and Programming Manual iii
Table of Contents
Modes of Operation ................................................................. 32
Normal Mode ....................................................................................32
Bypass Mode ....................................................................................33
Secure Mode .....................................................................................33
Changing the Modes of Operation .................................................33
Auxiliary Input and Output ....................................................... 35
Door Alarms ............................................................................. 35
Internal Case and Back Tamper .............................................. 35
Lockout Feature (Keypad/Card Tamper) ................................ 35
REX Function ........................................................................... 36
Secured Intelligent Power Supply ............................................ 36
Programming as a Controller .................................................. 37
Entering Programming Mode ..........................................................38
Exiting Programming Mode ............................................................38
Changing Lock Strike Code .............................................................39
Changing Auxiliary Code..................................................................39
Changing the Programming Code ..................................................40
Changing the Normal/Secure Code ...............................................41
Changing the Normal/Bypass Code and Door Chime Settings ...41
Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike
Release Time ....................................................................................42
Defining the Auxiliary Input and Output .........................................43
Setting the Lockout Feature ............................................................49
Setting the Backlight Behavior ........................................................50
Selecting the Credential Format .....................................................50
Enrolling Primary and Secondary Codes........................................51
Deleting Primary and Secondary Codes ........................................54
Relay Codes Assignment.................................................................57
iv AYC-E60 Installation and Programming Manual
Table of Contents
PIN Code Length/Factory Default Settings ...................................59
Replacing a Lost Programming Code ............................................60
Replacing a Lost Normal/Secure Code ..........................................60
Technical Specifications ..................................................... 61
Declaration of Conformity ................................................... 63
Limited Warranty ................................................................. 64
AYC-E60 Installation and Programming Manual v
List of Figures
List of Figures
Figure 1: Drilling and Mounting Template..........................................................11
Figure 2: Controller Application Wiring Diagram ...............................................14
Figure 3: Controller Wiring – Using the Internal Power ....................................15
Figure 4: Controller Wiring – Using the External Power ...................................15
vi AYC-E60 Installation and Programming Manual
List of Tables
List of Tables
Table 1: Wiring the Reader to the Controller......................................................12
Table 3: Reader Programming Menu .................................................................17
Table 4: Controller Programming Menu.............................................................37
Table 5: Quick Reference Guide for Auxiliary Mode Setting ............................44
AYC-E60 Installation and Programming Manual vii
Notice and Disclaimer
Notice and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein.
Before attempting to install and/or use the system, the installer and the user must read this manual and become familiar with all safety requirements and operating procedures.
The system must not be used for purposes other than those for which it was designed.
The use of the software associated with the system and/or product, if applicable, is subject to the terms of the license provided as part of the purchase documents.
ROSSLARE exclusive warranty and liability is limited to the warranty and liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with the maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury.
The text, images and graphics contained in the manual are for the purpose of illustration and reference only.
All data contained herein subject to change without prior notice.
In no event shall manufacturer be liable for any special, direct, indirect, incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury).
All wiring diagrams are intended for reference only, the photograph or graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s).
8 AYC-E60 Installation and Programming Manual
Introduction
1.
Introduction
The AYC-E60 is a Rosslare go PROX and PIN reader with Genuine
HID Technology ™ , as well as Rosslare's Convertible technology. The unit automatically determines whether to function as a reader or as a secured standalone controller. If the unit is connected to a standard access control unit, then it functions as a reader. If the unit is connected to a Rosslare secured intelligent power supply, it functions as a 500 user secured standalone controller.
As a reader, the unit can read all HID Prox cards/tags (125 kHz
FSK) using Genuine HID Technology and outputs HID Prox card data in Wiegand according to the number of bits of data stored on the card. The unit also reads Rosslare proximity cards (125 kHz) and can output Rosslare proximity card data as Wiegand 26-Bit,
Clock & Data, and Wiegand + PIN.
As a controller, the unit accepts up to 500 users, and allows entry via a personal identification number (PIN) and/or by presenting a proximity card. The PIN code length for the controller has several options. The PIN code length can be a set number of 4, 5, or 6 digits or it can be flexible from 4 to 8 digits.
1.1
Box Content
Before beginning, verify that all of the following is in the box. If anything is missing, please report the discrepancy to your nearest
Rosslare office.
One AYC-E60 unit
Installation kit
Installation and operating instructions
AYC-E60 Installation and Programming Manual 9
Introduction
1.2
Ancillary Equipment
The following equipment is required to complete your installation:
When functioning as a reader:
Compatible host controller (not supplied)
When functioning as a controller:
A secured intelligent power supply – such as the PC-25T, PS-
A25T, PS-C25T, or PS-C25TU secure controllers
This unit connects to the following:
Electric lock strike mechanism or a magnetic lock device, which implements fail safe (power to lock) or fail secure
(power to open) functions
Request-to-Exit (REX) button – normally open type. Switch is closed when pressed
Door monitor switch
Rosslare accessories can be found on www.rosslaresecurity.com
.
10 AYC-E60 Installation and Programming Manual
Installation
2.
Installation
Installation of an RFID reader adjacent to metallic surfaces might alter the reader’s specifications. To diminish this interference, use a plastic spacer when mounting the reader.
2.1
Mounting
Before starting, select the location to mount the unit. This location should be at shoulder height.
To mount the AYC-E60:
1.
For wall mounting, use the included mounting template as a
guide for drilling holes for mounting screws and wiring (Figure
1). For US Gang Box mounting, no drilling is necessary.
Figure 1: Drilling and Mounting Template
AYC-E60 Installation and Programming Manual 11
Installation
2.
At the bottom of the unit’s case, remove the screw.
3.
Insert the unit’s cable wire into the cable hole and wire the unit
4.
Screw the unit to its mounting location.
5.
Carefully re-attach the front cover of the unit.
6.
Secure the front cover by using the supplied security Torx screw. A Torx security screw tool is provided to tighten the security Torx screw.
2.2
Wiring
The unit is supplied with a 6-conductor 56-cm (22-in.) pigtail with exposed wires coated with solder.
2.2.1
Wiring the Unit as a Reader
If you connect the unit to a standard access control unit, it automatically functions as a reader.
To connect the unit as a reader (to a controller):
1.
Select the appropriate connections according to Table 1.
Table 1: Wiring the Reader to the Controller
Wire Color Function
Black/Shield Ground (-)
Red Vin (+)
Green Data 0/Data (D0)
White
Brown
Purple
Data 1/Clock (D1)
LED control
Tamper
2.
Prepare the controller cable by cutting the cable jacket back 3.2 cm (1¼”) and strip the wire 1.3 cm (½”).
3.
Splice the reader’s pigtail wires to the corresponding controller wires and cover each joint with insulating tape.
12 AYC-E60 Installation and Programming Manual
Installation
4.
If the tamper output is being utilized, connect the purple wire to the correct input on the controller.
5.
Trim and cover all conductors that are not used.
• The individual wires extending from the reader are color-coded according to the required Wiegand standard.
• When using a separate power supply for the reader, this supply and the controller’s power supply must have a common ground. A linear power supply is recommended.
• Attach the cable shield wire on the reader to an earth ground (best), or to a signal ground connection at the panel or power supply end of the cable. This configuration is best for shielding the reader cable from external interference.
2.2.2
Wiring the Unit as a Controller
If you connect the unit to a Rosslare secured power supply, it automatically functions as a controller.
To connect the unit as a controller:
1.
Select the appropriate connections according to Table 2.
Table 2: Wiring the Unit as a Controller
Controller Wire Color Function
+
-
C 1
C 2
AUX. IN
N/A
Red
Black
White
Green
Brown
Purple
Note
+DC Input
Ground
Wired to the PS-x25x
Wired to the PS-x25x
Communication Wired to the PS-x25x
Communication Wired to the PS-x25x
Auxiliary Input
Not in use
Wired to input
N/A
Attach the cable shield wire on the unit to an earth ground (best).
You can also attach it to a signal ground connection at the panel or power supply end of the cable. This configuration is best for shielding the controller cable from external interference.
2.
Prepare the secured power supply’s cable by cutting the cable jacket back 3.2 cm (1¼”) and strip the wire 1.3 cm (½”).
AYC-E60 Installation and Programming Manual 13
Installation
3.
Splice the controller pigtail wires to the corresponding secured power supply’s wires and cover each joint with insulating tape.
4.
Trim and cover all conductors not used.
5.
To connect the unit to the desired power supply option, refer to the relevant wiring diagrams that follow.
Figure 2 shows the wiring for the controller application using a dual
relay secured intelligent power supply.
Figure 2: Controller Application Wiring Diagram
14 AYC-E60 Installation and Programming Manual
Installation
Figure 3 shows the auxiliary output connection using the internal
power.
Figure 3: Controller Wiring – Using the Internal Power
Figure 4 shows the auxiliary output connection using the external
power.
Figure 4: Controller Wiring – Using the External Power
AYC-E60 Installation and Programming Manual 15
Reader Operation
3.
Reader Operation
The AYC-E60 can function both as a reader and as a controller. If the unit is connected to standard access controller, it functions as a reader, indicated by one beep immediately after power-on reset.
3.1
General
The default mode of the reader is Standby mode. In Standby mode, the unit is ready to receive data from a presented proximity card or an entered PIN code.
Programming the reader is done via the unit's keypad driven
programming menu system (Section 3.2).
Keypad data can be sent via one of eight keypad transmission
formats. For more information, see Section 3.2.3.
HID Prox card data is output in Wiegand according to the number of
bits of data stored on the card. See Section 3.2.4 for more
information.
Rosslare proximity cards presented to the reader can output card data as Wiegand 26-Bit, Clock & Data, and Wiegand + PIN. See
Section 3.2.5 for more information.
When the reader is in Standby mode, the left LED is red and the right LED is off.
Red
When the reader is in Programming mode, the left LED is off and the right LED is green.
When a proximity card is presented or a keypad entry is being transmitted, the left LED flashes green.
Green
Green
16 AYC-E60 Installation and Programming Manual
Reader Operation
3.2
Programming as a Reader
Programming is done solely via the unit's keypad driven
Programming Menu System. During the manufacturing process, certain codes and settings are pre-programmed. These settings are called the default factory settings.
Table 3 shows the names of all the reader programming menus.
Default factory settings are marked by *.
Table 3: Reader Programming Menu
Menu Description Default
1 Selecting Keypad Transmission Format
Single Key, Wiegand 6-Bit (Rosslare Format)
Single Key, Wiegand 6-Bit with Nibble + Parity Bits
Single Key, Wiegand 8-Bit, Nibbles Complemented
4 Keys Binary + Facility code, Wiegand 26-Bit
1 to 5 Keys + Facility code, Wiegand 26-Bit
6 Keys Binary-Coded Decimal (BCD) and Parity Bits,
Wiegand 26-Bit
Single Key, 3x4 Matrix Keypad
1 to 8 Keys BCD, Clock & Data
Single key, Wiegand 4-Bit
2 Selecting Rosslare Proximity Card Transmission Format
Wiegand 26-Bit
Clock & Data
Wiegand Card + PIN
3 Changing the Programming code
4 Changing the Facility code
6 Setting the Backlight
Always off
Always on
10 sec. backlight after key press, otherwise off
10 sec. backlight after key press, otherwise dimmed
*
*
1234
0
*
AYC-E60 Installation and Programming Manual 17
Reader Operation
Menu Description Default
6 Setting Credential Format
Rosslare Proximity
HID Prox
Rosslare Proximity + HID Prox
0 Return to Factory Default Settings
3.2.1
Entering Programming Mode
To reach the Programming Menu System, the unit must first be placed into Programming mode.
*
• The factory 4-digit Programming code is 1234.
• If a Programming code is not entered within 30 seconds, the unit returns to Standby mode.
To enter Programming mode:
1.
Press # four times.
The left LED turns off and the right LED turns red.
Red
2.
Enter your 4-digit Programming code.
If the Programming code is valid, the right
LED turns green.
Green
If the Programming code is invalid, you hear a long beep and the reader returns to Standby mode.
If no key is pressed for 30 seconds while in Programming mode, the unit returns to Standby mode
18 AYC-E60 Installation and Programming Manual
Reader Operation
3.2.2
Exiting Programming Mode
To exit Programming mode:
1.
Press # to exit Programming mode at any time.
You hear a beep.
The left LED turns red and the right LED turns off.
Red
This indicates that the unit has returned to Standby mode.
3.2.3
Selecting Keypad Transmission Format
There are eight keypad transmission formats.
More information on each of the keypad transmission formats is
Only one keypad transmission format can be active at any one time.
To select the keypad transmission format:
1.
Enter Programming mode.
2.
Press 1 to enter Menu 1.
Green
The left LED turns red.
Red Green
AYC-E60 Installation and Programming Manual 19
Reader Operation
3.
Enter one of the following options:
1 – Single Key, Wiegand 6-Bit (Rosslare Format) (default)
2 – Single Key, Wiegand 6-Bit with Nibble + Parity Bits
3 – Single Key, Wiegand 8-Bit, Nibbles Complemented
4 – 4 Keys Binary + Facility Code, Wiegand 26-Bit
5 – 1 to 5 Keys + Facility Code, Wiegand 26-Bit
6 – 6 Keys BCD and Parity Bits, Wiegand 26-Bit
8 – 1 to 8 Keys BCD, Clock & Data Single Key
9 – Single Key, Wiegand 4-Bit
When selecting Option 8, the right LED turns orange and an additional input is required to specify the number of keys in the PIN code.
You hear three beeps.
The system returns to Standby mode.
Red
If an incorrect option number is entered, the reader returns to
Standby mode and the keypad transmission format remains unchanged.
3.2.3.1
Keypad Transmission Formats
Option 1: Single Key, Wiegand 6-Bit (Rosslare Format)
Each key press immediately sends 4 bits with 2 parity bits added – even parity for the first 3 bits and odd parity for the last 3 bits.
0 = 1 1010 0 ="A" in Hexadecimal
1 = 0 0001 0
2 = 0 0010 0
3 = 0 0011 1
4 = 1 0100 1
5 = 1 0101 0
6 = 1 0110 0
7 = 1 0111 1
8 = 1 1000 1
9 = 1 1001 0
* = 1 1011 1 = "B" in Hexadecimal
# = 0 1100 1 = "C" in Hexadecimal
20 AYC-E60 Installation and Programming Manual
Reader Operation
Option 2: Single Key, Wiegand 6-Bit Nibble and Parities
Each key press immediately sends 4 bits with 2 parity bits added – even parity for the first 3 bits and odd parity for the last 3 bits.
0 = 0 0000 1
1 = 0 0001 0
2 = 0 0010 0
3 = 0 0011 1
6 = 1 0110 0
7 = 1 0111 1
8 = 1 1000 1
9 = 1 1001 0
4 = 1 0100 1
5 = 1 0101 0
* = 1 1010 0 = "A" in Hexadecimal
# = 1 1011 1 = "B" in Hexadecimal
Option 3: Single Key, Wiegand 8-Bit Nibbles Complemented
This option inverts the most significant bits in the message leaving the least 4 significant bits as BCD representation of the key. The host system receives an 8-bit message.
0 = 11110000
1 = 11100001
2 = 11010010
3 = 11000011
4 = 10110100
5 = 10100101
6 = 10010110
7 = 10000111
8 = 01111000
9 = 01101001
* = 01011010 = "A" in Hexadecimal
# = 01001011 = "B" in Hexadecimal
Option 4: 4 Keys Binary + Facility Code, Wiegand 26-Bit
This option buffers 4 keys and outputs keypad data with a 3-digit
Facility code like a standard 26-bit card output.
The Facility code is set in Programming Menu 4 and can be in the range 000 to 255. The factory default setting for the Facility code is
000 (see Section 3.2.7 for more information).
The keypad PIN code is 4 digits in length and can range between
0000 and 9999. On the fourth key press of the 4-digit PIN code, the data is sent across the Wiegand Data lines as binary data in the same format as a 26-bit card.
AYC-E60 Installation and Programming Manual 21
Reader Operation
If * or # are pressed during PIN code entry, the keypad clears the
PIN code entry buffer, generates a beep, and is ready to receive a new 4-digit keypad PIN code.
If the entry of the 4-digit keypad PIN code is disrupted and no number key is pressed within 5 seconds, the keypad clears the PIN code entry buffer, generates a beep, and is ready to receive a new
4-digit keypad PIN code:
(EP) FFFF FFFF AAAA AAAA AAAA AAAA (OP)
Where:
EP = Even parity for first 12 bits
OP = Odd parity for last 12 bits
F = 8-Bit Facility code
A = 16-Bit code generated from keypad
Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit
Option 5 buffers up to 5 keys and outputs keypad data with a
Facility code like a 26-bit card output.
The Facility code is set in Programming Menu 4 and can be in the range 000 to 255. The factory default setting for the Facility code is
000 (see Section 3.2.7 for more information). The keypad PIN code
can be one to five digits in length and can range between 1 and
65,535. When entering a keypad PIN code that is less than 5 digits in length, # must be pressed to signify the end of PIN code entry.
For keypad PIN codes that are 5 digits in length, on the fifth key press of the 5-digit PIN code, the data is sent across the Wiegand
Data lines as binary data in the same format as a 26-bit card.
If * is pressed during PIN code entry or a PIN code greater than
65,535 is entered, the keypad clears the PIN code entry buffer, generates a beep and is ready to receive a new 5-digit keypad PIN code.
22 AYC-E60 Installation and Programming Manual
Reader Operation
If the entry of the 1- to 5-digit keypad PIN code is disrupted and a number key or # is not pressed within 5 seconds, the keypad clears the PIN code entry buffer, generates a medium length beep, and is ready to receive a new 1- to 5-digit keypad PIN code:
(EP) FFFF FFFF AAAA AAAA AAAA AAAA (OP)
Where:
EP = Even parity for first 12 bits
OP = Odd parity for last 12 bits
F = 8-Bit Facility code
A = 16-Bit code generated from keypad
Option 6: 6 Keys BCD and Parity Bits, Wiegand 26-Bit
This option sends buffer of 6 keys, adds parity, and sends a 26-bit
BCD message. Each key is a four bit equivalent of the decimal number.
The keypad PIN code must be 6 key presses in length. On the sixth key press of the 6-digit PIN code, the data is sent across the
Wiegand Data lines as a BCD message.
If the entry of the 6-digit keypad PIN code is disrupted and a number key or # is not pressed within 5 seconds, the keypad clears the PIN code entry buffer, generates a medium length beep, and is ready to receive a new 6-digit keypad PIN code:
(EP) AAAA BBBB CCCC DDDD EEEE FFFF (OP)
Where:
EP = Even parity for first 12 bits
OP = Odd parity for last 12 bits
A = The first key entered
B = Second key entered
C = Third key entered
D = Fourth key entered
E = Fifth key entered
F = Sixth key entered
AYC-E60 Installation and Programming Manual 23
Reader Operation
Option 8: 1 to 8 Keys BCD, Clock & Data
Option 8 buffers up to 8 keys and outputs keypad data without a
Facility code like standard Clock and Data card output.
The keypad PIN code can be one to eight digits in length. The PIN code length is selected while programming the reader for Option 8.
The reader transmits the data when it receives the last key press of the PIN code. The data is sent across the two data output lines as binary data in Clock & Data format.
If * or # is pressed during PIN code entry, the keypad clears the PIN code entry buffer, generates a beep, and is ready to receive a new keypad PIN code.
If the entry of the keypad PIN code is disrupted and a number key or # is not pressed within 5 seconds, the keypad clears the PIN code entry buffer, generates a medium length beep, and is ready to receive a new keypad PIN code.
Option 9: Single Key, Wiegand 4-Bit
With this option, each key press immediately sends 4 bits of data, with no parity bits added.
0 = 0000
1 = 0001
2 = 0010
3 = 0011
4 = 0100
5 = 0101
6 = 0110
7 = 0111
8 = 1000
9 = 1001
*= 1010 ="A" in Hexadecimal
#=1011 ="B" in Hexadecimal
3.2.4
Selecting HID Prox Card Transmission Format
The AYC-E60 can read all HID Prox cards/tags (125 kHz) using
Genuine HID Technology and outputs HID Prox card data in
Wiegand format according to the number of bits of data stored on the card.
24 AYC-E60 Installation and Programming Manual
Reader Operation
3.2.5
Selecting Rosslare Proximity Card Transmission
Format
The AYC-E60 can read Rosslare proximity cards (125 kHz) and can output Rosslare proximity card data as Wiegand 26-Bit, Clock &
Data, and Wiegand + PIN.
More information on each of the Rosslare proximity card
transmission formats is presented in Section 3.2.5.1.
To select the Rosslare proximity card transmission format:
1.
Enter Programming mode.
2.
Press 2 to enter Menu 2.
Green
The left LED turns red.
Red Green
3.
Enter one of the following options:
1 – Wiegand 26-Bit
2 – Clock & Data
3 – Wiegand Card + PIN
You hear three beeps.
The system returns to Standby mode. Red
If an incorrect option is entered, the reader returns to Standby mode and the keypad transmission format remains unchanged.
3.2.5.1
Rosslare Proximity Card Transmission Formats
Option 1: Wiegand 26-Bit
In this mode, 3 LSB bytes from the card serial number (UID) are transmitted in Wiegand 26-Bit format. Two parity bits are added. An even parity bit is sent first, followed by three bytes of card data, and by an odd parity bit.
(EP) AAAA AAAA AAAA AAAA AAAA AAAA (OP)
AYC-E60 Installation and Programming Manual 25
Reader Operation
Where: EP = Even parity for first 12 bits
OP = Odd parity for last 12 bits
A = 3 bytes code generated from card data
Option 2: Clock and Data
In this mode, up to 6 bytes of the card serial number are transmitted in Clock & Data format.
Option 3: Wiegand Card + PIN
This unique mode is intended to let host controllers get card and keypad data simultaneously. This option overrules the selected
Keypad Transmission Format and sends the keypad data as described below.
After a card is presented to the unit, the program LED starts to flash in green and indicates that the unit is waiting for the PIN code. If the entry of 1- to 5-digit keypad PIN code is disturbed and a number key or # is not pressed within 5 seconds, the keypad clears the card buffer and the PIN code entry buffer, generates a medium length beep, and is ready to receive a new card.
The keypad PIN code can be one to five digits in length in the range of 0 to 99,999. When entering a keypad PIN code, # must be pressed to signify the end of the PIN entry. When pressing # , the data is sent by the Wiegand data lines. If * is pressed, the keypad clears the card buffer and the PIN code entry buffer, generates a medium length beep, and is ready to receive a new card.
The AYC-E60 outputs card data is in Wiegand 26-Bit with the following keypad data in Wiegand 26-Bit format.
Card Data: (EP) AAAA AAAA AAAA BBBB BBBB BBBB (OP)
Where:
EP = Even parity for first 12 A bits
OP = Odd parity for last B 12 bits
PIN Data: (EP) 0000 AAAA BBBB CCCC DDDD EEEE (OP)
26 AYC-E60 Installation and Programming Manual
Reader Operation
Where:
A = The first key entered
B = Second key entered
D = Fourth key entered
E = Fifth key entered
C = Third key entered
EP = Even parity for first 12 bits OP = Odd parity for last 12 bits
If the PIN code is less than 5 digits, all the most significant nibbles are filled with 0.
Example: (EP) 0000 0000 0000 0000 AAAA BBBB (OP)
Where:
A = The first key entered B = Second key entered
EP = Even parity for first 12 bits OP = Odd parity for last 12 bits
3.2.6
Changing the Programming Code
• The Programming code cannot be erased; the code 0000 is invalid and does not erase the Programming code.
• The factory default 4-digit Programming code is 1234.
To change the Programming code:
1.
Enter Programming mode.
2.
Press 3 to enter Menu 3.
Green
The left LED turns red.
3.
Enter the new 4-digit code you wish to set as the Programming code.
You hear three beeps.
The system returns to Standby mode.
3.2.7
Changing the Facility Code
Red Green
Red
AYC-E60 Installation and Programming Manual 27
Reader Operation
• The Facility code can be in the range of 000 to 255.
• The default Facility code is 0.
To change the Facility code:
1.
Enter Programming mode.
2.
Press 4 to enter Menu 4.
Green
The left LED turns red.
Red Green
3.
Enter the new 3-digit code you wish to set as the Facility code.
You hear three beeps.
The system returns to Standby mode. Red
3.2.8
Setting the Backlight Behavior
To set the backlight behavior:
1.
Enter Programming mode.
Green
2.
Press 6 to enter Menu 6.
The left LED turns red.
Red Green
3.
Enter one of the following codes:
10 – Always off
11 – Always on
12 – Backlight is off, activates for 10 seconds when a key is pressed (left LED also goes on), after which it dims until off (left LED also goes off)
13 – Backlight is dimmed, activates for 10 seconds when a key is pressed (left LED also goes on), after which it returns to a dimmed level
28 AYC-E60 Installation and Programming Manual
Reader Operation
You hear three beeps.
The system returns to Standby mode.
3.2.9
Setting the Credential Format
To set the credential format:
Red
1.
Enter Programming mode.
Green
2.
Press 6 to enter Menu 6.
The left LED turns red.
Red Green
3.
Enter one of the following codes:
61 for Rosslare Proximity
62 for HID Prox
63 for Rosslare Proximity and HID Prox (default)
You hear three beeps.
The system returns to Standby mode. Red
3.2.10
Return to Factory Default Settings
You must be very careful before using this command! This erases the entire memory and returns all codes to their factory default setting.
To return to factory default settings:
1.
Enter Programming mode.
2.
Press 0 to enter Menu 0.
Green
Both LEDs flash red.
3.
Enter your 4-digit Programming code.
Red Red
AYC-E60 Installation and Programming Manual 29
Reader Operation
If the Programming code is valid, all memory is erased. You hear three beeps and the reader returns to Standby mode.
If the Programming code is invalid, you hear a long beep and the reader returns to Standby mode without erasing the memory of the reader
3.2.11
Replacing a Lost Programming Code
In the event that the Programming code is forgotten, the unit can be reprogrammed in the field.
To replace a lost Programming code:
1.
Remove power from the reader.
2.
Activate the tamper by removing the reader from the wall or removing the reader's case.
3.
Apply power to the reader.
4.
You now have 10 seconds to enter Programming mode using the factory default Programming code 1234.
30 AYC-E60 Installation and Programming Manual
Controller Operation
4.
Controller Operation
The AYC-E60 can function both as a reader and as a controller. If the unit is connected to a Rosslare secured intelligent power supply, it functions as a controller indicated by two beeps immediately after power-on reset.
The Lock Strike Output and REX input are not located on the unit, eliminating the possibility of unauthorized entry to the restricted area.
4.1
Normal, Secure, and Master Users
The unit accepts up to 500 users and provides entry via the use of
PIN codes and/or proximity cards. Each user is provided with two code memory slots: Memory Slot 1 (Primary code) and Memory
Slot 2 (Secondary code).
The PIN code length has several options. The PIN code length can be a set number of 4, 5 or 6 digits or it can be a 4–8 digits option.
When choosing the 4–8 digit option, please note that you should either enter zeros before the code, or press # at the end (for example if your code is 12345, enter either 00012345 or 12345#) .
Entering a code refers to either PIN or card depending on the model you have.
The way in which the two memory slots are programmed determines a user’s access level and also determines the way in which the unit grants access in its three modes of operation. There are three user levels:
Normal
A Normal user only has a Primary code and is only granted access when the unit is in Normal or Bypass mode.
AYC-E60 Installation and Programming Manual 31
Controller Operation
Secure
A Secure user must have a Primary and Secondary code programmed; the two codes cannot be the same. The Secure
User can gain access when the unit is in any of its three modes of operation. In Normal mode, the Secure user must use the
Primary code to gain entry. In Secure mode, the Secure user must present both the Primary and Secondary codes to gain entry.
Master
A Master user must have both Primary and Secondary codes programmed with the same code. The Master user can gain access during any mode of operation by presenting the PIN code and/or proximity card one time to the controller. (The
Master user is convenient but is less secure than a Secure user.)
4.2
Modes of Operation
There are three modes of operation:
4.2.1
Normal Mode
The left LED is green.
Green
Normal mode is the default mode. In Normal mode, the door is locked until a Primary code is presented to the controller. Special codes such as Lock Strike code and Auxiliary code are active in
Normal mode. (See Sections 4.9.3 and 4.9.4 for more information.)
32 AYC-E60 Installation and Programming Manual
Controller Operation
4.2.2
Bypass Mode
The left LED is orange.
Orange
In Bypass mode, access to the premises is dependent on whether the controller's Lock Strike Relay is programmed for Fail Safe
Operation or Fail Secure Operation. When the Lock Strike is programmed for Fail Secure Operation, the door is locked until * is pressed. When the Lock Strike is programmed for Fail Safe
Operation, the door is constantly unlocked.
4.2.3
Secure Mode
The left LED is red.
Only Secure and Master users can access the premises in Secured mode.
Red
A Secure user must enter the Primary and Secondary codes to gain entry. After entering the Primary code, the right LED flashes green for 10 seconds, during which the Secondary code must be entered.
A Master user only needs to present the code once to gain entry.
4.2.4
Changing the Modes of Operation
4.2.4.1
Changing from Normal Mode to Secure Mode
The default factory setting for the Normal/Secure code is 3838.
To change from Normal to Secure mode:
1.
Enter the Normal/Secure code.
Green
The left LED flashes red.
Red
2.
Press # to confirm the mode change.
The left LED stops flashing.
Red
AYC-E60 Installation and Programming Manual 33
Controller Operation
4.2.4.2
Changing from Secure Mode to Normal Mode
The default factory setting for the Normal/Secure code is 3838.
To change from Secure to Normal mode:
1.
Enter the Normal/Secure code.
The left LED flashes green.
Red
Green
2.
Press # to confirm the mode change.
The left LED stops flashing.
4.2.4.3
Changing from Normal Mode to Bypass Mode
See Section 4.9.7 to create/modify the Normal/Bypass code.
To change from Normal to Bypass mode:
Green
1.
Enter the 4-digit Normal/Bypass code.
Green
The left LED flashes orange.
Orange
2.
Press # to confirm the mode change.
The left LED stops flashing.
4.2.4.4
Changing from Bypass Mode to Normal Mode
See Section 4.9.7 to create/modify the Normal/Bypass code.
To change from Bypass to Normal mode:
Orange
1.
Enter the 4-digit Normal/Bypass code.
Orange
The left LED flashes green.
Green
2.
Press # to confirm the mode change.
The left LED stops flashing.
Green
34 AYC-E60 Installation and Programming Manual
Controller Operation
4.3
Auxiliary Input and Output
For optimum usability in different applications, the controller’s auxiliary input and output can be configured in 10 different modes
of operation (see Section 4.9.9).
4.4
Door Alarms
Door alarms can be generated by connecting the Auxiliary Input to a
Door Position Switch. Either Door-Forced or Door-Ajar conditions are supported, as well as a configurable delay timer for each alarm type. Only one door-alarm is enabled at any one time. Door alarms may activate auxiliary output and siren depending on the auxiliary settings.
4.5
Internal Case and Back Tamper
If the unit is forcibly opened or it is removed from the wall, a tamper event is triggered. A tamper output opens sending a signal to the connected alarm system (purple wire); the event closes when the tamper is closed (case is re-closed or re-attached to the wall).
The tamper event can also activate the auxiliary output if the
controller is in Auxiliary Mode 3 (see Table 5).
4.6
Lockout Feature (Keypad/Card Tamper)
If the controller is presented with wrong codes (PIN or card) consecutively several times, the unit goes into Lockout mode.
When a lockout occurs, the controller’s reader and keypad are deactivated so no codes can be entered until the set lockout period expires.
During Lockout mode, the left LED is Off, the right LED flashes red, and the controller beeps every two seconds.
AYC-E60 Installation and Programming Manual 35
Controller Operation
4.7
REX Function
The REX button is connected to a Rosslare secured intelligent power supply. The REX button must be located inside the premises to be secured and is used to open the door without the use of a PIN code. It is usually located in a convenient location, such as inside the door or at a receptionist's desk. The function of the REX button depends on whether the Lock Strike Relay is programmed for Fail
Safe Operation or Fail Secure Operation.
Fail Secure Operation
From the moment the REX button is pressed, the door is unlocked until the Lock Strike Release Time passes. After this time, the door is locked even if the REX button is not released.
Fail Safe Operation
From the moment the REX button is pressed, the door is unlocked until the REX button is released, plus the Lock Strike
Release Time. In this case, the Lock Strike Relay only begins its count down once the REX button is released.
4.8
Secured Intelligent Power Supply
Rosslare’s secured intelligent power supplies are designed for use with Rosslare's secured standalone access control units, including the AYC-E60. The unit is designed to operate indoors and is installed within the secured premises. The unit must be used with one of Rosslare’s secured intelligent power supplies, which provides Lock Strike output and REX input. The AYC-E60 and the power supply communicate through a proprietary Rosslare protocol, which provides a secure link between them. This in turn activates the door lock.
Each power supply unit contains a speaker connection for all sounder abilities.
For more information, see the PS-x25x Installation Manual .
36 AYC-E60 Installation and Programming Manual
Controller Operation
4.9
Programming as a Controller
Programming is performed solely via the unit's keypad driven
Programming Menu System. To reach the Programming Menu
System, the unit must first be placed into Programming mode. See
Section 4.9.1 for more information.
During the manufacturing process, certain codes and settings are pre-programmed. These settings are the called the default factory settings.
Table 4 shows the names of all the controller programming menus.
It also shows of all the default factory codes and settings.
Table 4: Controller Programming Menu
Menu
No.
Menu Description Default
4 digits
5 digits
6 digits 4–8 digits
1 Changing Lock Strike Code
2 Changing Auxiliary Code
2580 25802 258025 25802580
0852 08520 085208 08520852
3 Changing Program Code 1234 12341 123412 12341234
4 Changing Normal/Secure Code 3838 38383 383838 38383838
5 Changing Normal/Bypass Code
6 Changing Door Release Time
N/A
0004
7
8
Defining auxiliary inputs/outputs
Set Lockout
Backlight Behavior
Credential Format
Enrolling PIN Code
Deleting PIN Code
9 Code Assignment with
Strike/Auxiliary
0 Return to Factory
Defaults/Change PIN Code
Length
2004
4000
5100
6300
N/A
N/A
N/A
N/A
AYC-E60 Installation and Programming Manual 37
Controller Operation
You will find instructions for each of the above menu items in the following subsections.
4.9.1
Entering Programming Mode
• The unit must be in Normal mode to enter Programming mode.
• The factory 4-digit Programming code is 1234.
• If a Programming code is not entered within five seconds, the unit returns to Normal mode.
To enter Programming mode:
1.
Press # twice.
The left LED turns off and the right LED turns red.
2.
Enter your 4-digit Programming code.
Red
The right LED turns green.
Green
4.9.2
Exiting Programming Mode
To exit Programming mode:
1.
Press # twice to exit Programming mode at any time.
You hear 3 beeps.
The left LED turns green and the right LED turns off.
Green
Wrong entries reset the controller back to Normal mode.
While in Programming mode, if no key is pressed for one minute, the unit returns to Normal mode.
38 AYC-E60 Installation and Programming Manual
Controller Operation
4.9.3
Changing Lock Strike Code
The Lock Strike code is mainly used as a method to quickly test the
Lock Strike Relay during installation.
When the first user is added to the controller, the default Lock
Strike code is automatically deleted. Once the code is programmed again, it is not deleted with the entry of additional user codes.
• Lock Strike code does not work in the Secure mode.
• Wrong entries return the controller to Normal mode.
• Code 0000 erases the Lock Strike code.
• The factory default 4-digit Lock Strike code is 2580.
To change the Lock Strike code:
1.
Enter Programming mode.
2.
Press 1 to enter Menu 1.
Green
The left LED turns red.
Red Green
3.
Enter the new code you wish to set as the
Lock Strike code.
You hear three beeps.
The system returns to Normal mode. Green
4.9.4
Changing Auxiliary Code
The Auxiliary code is mainly used as a method to quickly test the
Auxiliary Relay during installation.
• Auxiliary code does not work in the Secure mode.
• Wrong entries return the controller to Normal mode.
• Code 0000 erases the Auxiliary code.
• The factory default 4-digit Auxiliary code is 0852.
AYC-E60 Installation and Programming Manual 39
Controller Operation
To change the Auxiliary code:
1.
Enter Programming mode.
2.
Press 2 to enter Menu 2.
The left LED turns orange.
Green
Orange Green
3.
Enter the new Auxiliary code.
You hear three beeps.
The system returns to Normal mode.
4.9.5
Changing the Programming Code
Green
• The Programming code cannot be erased; the code 0000 is invalid and does not erase the Programming code.
• The factory default 4-digit Programming code is 1234.
To change the Programming code:
1.
Enter Programming mode.
2.
Press 3 to enter Menu 3.
Green
The left LED turns green.
3.
Enter the new 4-digit Programming code.
You hear three beeps.
The system returns to Normal mode.
Green Green
Green
40 AYC-E60 Installation and Programming Manual
Controller Operation
4.9.6
Changing the Normal/Secure Code
• Code 0000 erases the Normal/Secure code.
• This code is disabled if the Auxiliary Input is set to toggle between
Normal and Secure access modes.
• The default Normal/Secure code is 3838.
To change the Normal/Secure code:
1.
Enter Programming mode.
2.
Press 4 to enter Menu 4.
Green
The left LED flashes red.
Red Green
3.
Enter the new Normal/Secure code.
You hear three beeps.
The system returns to Normal mode. Green
4.9.7
Changing the Normal/Bypass Code and Door
Chime Settings
To change the Normal/Bypass code and door chime settings:
1.
Enter Programming mode.
Green
2.
Press 5 to enter Menu 5.
The left LED flashes orange.
Orange Green
3.
There are four different ways to program the Normal/Bypass code and door chime:
Disable both Bypass code and the door chime. Enter the code 0000 .
Disable Bypass code and enable the door chime. Enter the code 0001 .
AYC-E60 Installation and Programming Manual 41
Controller Operation
Enable Bypass code and disable the door chime. Enter any code ending with 0.
Enable Bypass code and enable the door chime. Enter a code not ending with 0.
You hear three beeps.
The system returns to Normal mode. Green
4.9.8
Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
The default value is 0004, which corresponds to Fail Secure operation, no siren, and 4-seconds Lock Strike release time.
To set the Fail Safe/Secure Operation, Tamper Siren and Lock
Strike Release Time:
1.
Enter Programming mode.
2.
Press 6 to enter Menu 6.
Green
The left LED flashes green.
Green Green
3.
Construct a code using the following instructions:
First digit
For Fail Secure Operation, the first digit should be 0 .
For Fail Safe Operation the first digit should be 1 .
Second digit
Siren Time in minutes (1–9, 0 – disabled)
Third and fourth digits
Enter the number of seconds (from 1 to 99) that you want the Lock Strike to be released.
42 AYC-E60 Installation and Programming Manual
Controller Operation
For example, 0312 means a Fail Secure Operation consisting of a 3-minute siren and a 12-second Lock Strike release time.
You hear three beeps.
The system returns to Normal mode. Green
4.9.9
Defining the Auxiliary Input and Output
The default auxiliary setting is 2004.
To define the auxiliary input and output:
1.
Enter Programming mode.
2.
Press 6 to enter Menu 6.
Green
The left LED flashes green.
Green Green
3.
Construct a code using the following instructions:
Second digit (Auxiliary Mode)
In addition to the Lock Strike Relay and Lock Strike REX, the unit features an Auxiliary Input. The Auxiliary mode defines the function of the Auxiliary Input.
Third and fourth digits (Auxiliary Setting)
Each of the Auxiliary modes has a 2-digit setting that
affects how the Auxiliary mode functions (Table 5).
You hear three beeps.
The system returns to Normal mode. Green
AYC-E60 Installation and Programming Manual 43
Controller Operation
7
8
Auxiliary
Mode
0
1
2
3
Table 5: Quick Reference Guide for Auxiliary Mode Setting
Auxiliary
Input
Function
AUX REX
Auxiliary
Output
Activated by
Valid code or
AUX REX
Normal/Secure switch
Valid code
Normal/Secure switch
Star button
( )
Auxiliary
Relay
N.O.
N.O.
N.O.
Normal/Secure switch
Tamper event N.C.
Auxiliary Settings
(in seconds)
01 to 99 Aux. relay release time
00 Aux. relay toggle
01 to 99 Aux. relay release time
00 Aux. relay toggle
01 to 99 Aux. relay release time
00 Aux. relay toggle
01 to 99 Aux. relay release time
00 Aux. relay tamper activated
4
5
Normal/Secure switch
Direct shunt N.O.
Door Monitor Shunt N.C.
01 to 99 Shunt time
6
9
Door Monitor Forced door N.C.
Door Monitor Door ajar
LED control –
Green
Valid code
LED control –
Red
Valid code
N.C.
N.O.
N.O.
01 to 99 Maximum shunt time
01 to 99 Forced delay
01 to 99 Ajar delay
01 to 99 Aux. relay release time
00 Aux. relay toggle
01 to 99 Aux. relay release time
00 Aux. relay toggle
44 AYC-E60 Installation and Programming Manual
Controller Operation
The following subsections describe each Auxiliary mode.
4.9.9.1
Auxiliary Mode 0
Auxiliary input function: Activates the auxiliary output
Auxiliary output activated by: Valid user code, Auxiliary code,
Auxiliary input
For example, in Auxiliary Mode 0, the controller can function as a two-door controller. The auxiliary relay is to be attached to the lock on the second door. The auxiliary setting defines the door open time for the second door. The auxiliary input is to be attached to the
REX pushbutton for the second door. The Door Monitor input feature for the second door is not enabled when using this mode.
4.9.9.2
Auxiliary Mode 1
Auxiliary input function: Toggles Normal/Secure modes
Auxiliary output activated by: Valid user code, Auxiliary code
For example, in Auxiliary Mode 1, the controller can function as a two-door controller. The auxiliary relay is to be attached to the lock on the second door. REX feature for the second door is not enabled when using this mode.
The auxiliary setting defines the door open time for the second door. The auxiliary input can switch the mode of operation of the controller between Normal and Secure mode. By connecting a switch timer or alarm system output to the auxiliary input, the controller can be automatically switched from Normal mode
(during office hours) to Secure mode (after office hours).
4.9.9.3
Auxiliary Mode 2
Auxiliary input function: Toggles normal/secure modes
Auxiliary output activated by: Asterisk Button (*)
For example, in Auxiliary Mode 2, the auxiliary relay can function as a general purpose time switch that can be activated when the asterisk button (*) is depressed. The auxiliary setting establishes for how long the auxiliary relay is to be activated. The auxiliary input can switch the mode of operation of the controller between Normal
AYC-E60 Installation and Programming Manual 45
Controller Operation and Secure modes. By connecting a switch timer or alarm system output to the auxiliary input, the controller can be automatically switched from Normal mode (during office hours) to Secure mode
(after office hours).
4.9.9.4
Auxiliary Mode 3
Auxiliary input function: Toggles Normal/Secure modes
Auxiliary output activated by: Alarms
For example, in Auxiliary Mode 3, the auxiliary output is activated if the controller is tampered; that is, if the case is forcibly opened or removed from the wall. The auxiliary input can switch the mode of operation of the controller between Normal and Secure modes. By connecting a switch timer or alarm system output to the auxiliary input, the controller can be automatically switched from Normal mode (during office hours) to Secure mode (after office hours).
4.9.9.5
Auxiliary Mode 4
Auxiliary input function: Toggles Normal/Secure modes
Auxiliary output activated by: Direct shunt (explanation below)
For example, in Auxiliary Mode 4, the controller is capable of bypassing an alarm zone by shunting an alarm system’s door sensor. The auxiliary output is to be wired in parallel to the door sensor output. When in use, the auxiliary output is normally open and the door sensor functions normally. When a valid code is entered, the auxiliary relay shunts the door sensor for the duration of the shunt time, as defined by the auxiliary setting. If the door is left open longer than the shunt time, an alarm is triggered.
46 AYC-E60 Installation and Programming Manual
Controller Operation
4.9.9.6
Auxiliary Mode 5
Auxiliary input function : Door Monitor
Auxiliary output activated by: Shunt (explanation below)
For example, in Auxiliary Mode 5, the controller is capable of shunting an alarm system. In this mode, the auxiliary input is to be wired to the magnetic contact switch on the door. The auxiliary relay is wired to the alarm system. Without a valid code entered, the auxiliary relay matches the condition of the magnetic contact switch; if the door opens, the auxiliary relay opens; if the door closes, the auxiliary relay closes. When a valid code is entered, a countdown for maximum shunt time, as defined by the auxiliary setting, begins; if the door is not closed before the maximum shunt time, the alarm is triggered.
4.9.9.7
Auxiliary Mode 6
Auxiliary input function: Door Monitor
Auxiliary output activated by: Forced entry
For example, in Auxiliary Mode 6, the controller can trigger the auxiliary relay if the door has been forced. If the siren settings are enabled, the siren is activated.
In this mode, the auxiliary input functions as a door monitor switch and is wired to the magnetic contact switch on the door. The auxiliary relay is to be wired to the alarm system. If the door is forced open, the controller waits for the period of the forced door delay time to elapse and then it activates the auxiliary relay. The auxiliary setting sets the forced door delay period.
4.9.9.8
Auxiliary Mode 7
Auxiliary input function: Door Monitor
Auxiliary output activated by: Door Ajar (door held open)
For example, in Auxiliary Mode 7, the controller can trigger the auxiliary relay, if it detects that the door has been held open (ajar) too long. In this mode, the auxiliary input functions as a door monitor switch and is wired to the magnetic contact switch on the
AYC-E60 Installation and Programming Manual 47
Controller Operation door. The auxiliary relay is to be wired to the alarm system. If the door is opened, the controller waits for the Door Ajar Delay time to elapse and if the door does not close prior to the end of this period, the controller activates the auxiliary relay. The auxiliary setting defines the door-ajar time.
4.9.9.9
Auxiliary Mode 8
This mode controls the door indicator (right LED).
The right LED is not lit when:
• A valid code is entered
• While in Secure mode when waiting for Secondary code.
Auxiliary input function: Green LED control
Auxiliary output activated by: Valid user code, Auxiliary code
For example, in Auxiliary Mode 8, the controller can function as a
2-door controller and also provide LED indicator functionality control. The auxiliary relay is connected to the lock on the second door. The auxiliary setting defines the Door Open time for the second door. The auxiliary input is used to control the door indicator (right LED). If the auxiliary input is open, the right LED flashes green; if the auxiliary input is closed, the right LED flashes red.
4.9.9.10
Auxiliary Mode 9
This mode controls the door indicator (right LED).
The right LED is not lit when:
• A valid code is entered
• While in Secure mode when waiting for Secondary code.
Auxiliary input function: Red LED control
Auxiliary output activated by: Valid user code, Auxiliary code
For example, in Auxiliary Mode 9, the controller can function as a
2-door controller and also provide LED indicator functionality control. The auxiliary relay is connected to the lock on the second door. The auxiliary setting defines the Door Open time for the
48 AYC-E60 Installation and Programming Manual
Controller Operation second door. The auxiliary input is used to control the door indicator (right LED). If the auxiliary input is open, the right LED flashes red; if the auxiliary input is closed the right LED flashes green.
4.9.10
Setting the Lockout Feature
If the controller is presented with wrong codes (PIN or card) consecutively several times, the unit goes into Lockout mode.
When a lockout occurs, the controller keypad and reader are locked so no codes can be entered until the set lockout period expires.
During Lockout, the left LED is Off, the right LED flashes red, and the controller beeps every two seconds. The default setting for the
Lockout Feature is 4000 (Lockout Disabled).
Using the lockout feature is highly recommended, especially when using a short PIN code length (4 or 5 digits).
To set the lockout feature:
1.
Enter Programming mode.
2.
Press 6 to enter Menu 6.
Green
The left LED flashes green.
Green Green
3.
Construct a code using the following instructions:
Second digit
Set the number of wrong code attempts, which causes a
Lockout between 0 and 9 attempts.
Third and fourth digits
Sets the Duration of the lockout, between 00 and 99; the value is multiplied by ten, resulting in 0 to 990 seconds.
AYC-E60 Installation and Programming Manual 49
Controller Operation
4.9.11
Setting the Backlight Behavior
The controller allows you to define the way the unit’s backlight works.
To set the backlight behavior:
1.
Enter Programming mode.
Green
2.
Press 6 to enter Menu 6.
The left LED flashes green.
Green Green
3.
Enter one of the following codes:
5000 – Backlight off
5100 – Backlight on (default)
5200 – Backlight is off, activates for 10 seconds when a key is pressed, after which it dims until off
5300 – Backlight is dimmed, activates for 10 seconds when a key is pressed, after which it returns to a dimmed level
4.9.12
Selecting the Credential Format
To select the credential format:
1.
Enter Programming mode.
Green
2.
Press 6 to enter Menu 6.
The left LED flashes green.
Green Green
3.
Enter one of the following codes:
6100 – Rosslare Proximity
6200 – HID Prox
6300 – Rosslare Proximity + HID Prox (default)
50 AYC-E60 Installation and Programming Manual
Controller Operation
4.9.13
Enrolling Primary and Secondary Codes
4.9.13.1
Primary Codes
Primary codes can only be enrolled to an empty user slot, meaning a slot where there is no existing Primary code.
Primary codes must be unique, meaning one user’s Primary code may not be the same as other user’s Primary code.
Primary codes cannot be the same as any system codes, such as the Normal/Secure code or Lock Strike code.
Users who hold a Primary code can gain entry only during
Normal mode.
4.9.13.2
Secondary Codes
Secondary codes can only be enrolled to user slot that already has a Primary code enrolled but no Secondary code.
Secondary codes do not have to be unique, meaning multiple users can all hold the same Secondary code.
Secondary codes cannot be the same as any system codes, such as the Normal/Secure code or Lock Strike codes.
Users who hold Secondary codes can gain entry in any mode of operation.
4.9.13.3
Enrolling Methods
There are two methods to enroll Primary and Secondary codes:
Standard Method
The Standard Method is mainly used when the user slot number for the user you wish to program is known. You can program both Primary and Secondary codes using the Standard
Method (see Section 4.9.13.4).
AYC-E60 Installation and Programming Manual 51
Controller Operation
Code Search Method
The Code Search Method is mainly used when enrolling a user’s Secondary code and the User Slot code is unknown.
The Code Search method only works if a user’s Primary code is already enrolled but the Secondary code is not (see Section
4.9.13.4
Enrolling Primary and Secondary Codes using the
Standard Method
To enroll Primary and Secondary codes using the Standard method:
1.
Enter Programming mode.
2.
Press 7 to enter Menu 7.
Green
The right LED turns orange.
Orange
3.
Enter the 3-digit user slot number between
001and 500 for the slot to which you wish to enroll a Primary or Secondary code.
For example, User Slot 003 represents User #3.
If the selected slot has no Primary code, the left LED flashes green, indicating that the controller is ready to accept a Primary code.
If the selected slot already has a Primary code but no Secondary code, the left LED flashes red, indicating that the controller is ready to accept a Secondary code.
If the selected slot already has a Primary and
Secondary code, you hear a long beep and the controller returns to Normal mode.
Gree Orange
Red Orange
Green
52 AYC-E60 Installation and Programming Manual
Controller Operation
4.
Perform one of the following:
Enter the PIN code that you want to assign as the Primary or Secondary code for this slot number.
Present your user card that you want to assign as the
Primary or Secondary code for this slot number.
If the PIN or user card presented is valid, the left LED stops flashing and the controller is ready for you to enter the next
3-digit slot number (refer to Step 3) for the slot to which you
want to assign a code.
5.
Do one of the following:
Press # to move to the next available user slot number.
Enter another 3-digit user slot number.
If you do not wish to continue enrolling codes, press # twice and the controller returns to Normal mode.
4.9.13.5
Enrolling Secondary Codes using the Code Search
Method
The Code Search feature enables you to quickly enroll a Secondary code to a user who already has a Primary code.
To enroll secondary codes using the Code Search method:
1.
Enter Programming mode.
2.
Press 7 to enter Menu 7.
Green
The right LED turns orange.
3.
Enter 000 as the 3-digit user slot number.
Orange
The right LED flashes orange.
Orange
AYC-E60 Installation and Programming Manual 53
Controller Operation
4.
Perform one of the following:
Enter the PIN code belonging to the user for whom you wish to add a Secondary code.
Present the user card belonging to the user for whom you wish to add a Secondary code.
The left LED flashes red.
Red Orange
If the Primary code entered is not valid, you hear a long beep and the unit continues to wait for a valid Primary code.
5.
Perform one of the following:
Enter the PIN code to be used as the
Secondary code.
Present the user card to be used as the Secondary code.
If the Secondary code is valid, the controller beeps three times and returns to Normal mode.
If the Secondary code is invalid, the controller sounds a long beep, and the unit continues to wait for a valid Secondary code to be entered.
4.9.14
Deleting Primary and Secondary Codes
There are two methods to delete Primary and Secondary codes: the
Standard Method and the Code Search Method.
When deleting a user slot, both the Primary code and the Secondary code are erased.
It is recommended that a record be kept of added and deleted users so that it is easier to keep track of which user slots are empty and which user slots are not.
54 AYC-E60 Installation and Programming Manual
Controller Operation
4.9.14.1
Deleting Primary and Secondary Codes using the
Standard Method
To delete the Primary and Secondary codes using the Standard
Method:
1.
Enter Programming mode.
2.
Press 8 to enter Menu 8.
Green
The left LED turns red and the right LED turns orange.
3.
Enter the 3-digit User Slot code you wish to delete.
The left LED flashes red indicating the controller is waiting for the Programming code to confirm the deletion.
Red Orange
Red Orange
If the user slot is empty, you hear a long beep and the unit returns to Normal mode.
4.
Enter your 4-digit Programming code to confirm the deletion.
If the Programming code is valid, three beeps are heard and the controller returns to Normal mode.
If the Programming code is invalid, a long beep is heard and the controller returns to Normal mode.
AYC-E60 Installation and Programming Manual 55
Controller Operation
4.9.14.2
Deleting Primary and Secondary Codes using the Code
Search Method
To delete the Primary and Secondary codes using the Code Search
Method:
1.
Enter Programming mode.
2.
Press 8 to enter Menu 8.
Green
The left LED turns red and the right LED turns orange.
3.
Enter 000 as the 3-digit user slot number.
Red Orange
The right LED flashes orange.
4.
Perform one of the following:
Red Orange
Enter the PIN code of the Primary code belonging to the user you want to delete.
Present the user card of the Primary code belonging to the user you want to delete.
The left LED flashes red.
5.
Red Orange
Enter your 4-digit Programming code to confirm the deletion.
If the Programming code is valid, you hear three beeps and the unit returns to Normal mode.
If the Programming code is invalid, you hear a long beep and the unit returns to Normal mode.
56 AYC-E60 Installation and Programming Manual
Controller Operation
4.9.15
Relay Codes Assignment
When a Primary code is enrolled for any user, the user is authorized to activate the Lock Strike relay. However, different user codes may be set to operate the auxiliary relay instead or operate both the
Lock strike and auxiliary relay. Assigning such codes is possible for any valid user code entered in the controller. There are two methods to assign relay codes to users: a standard method and a search method.
4.9.15.1
Relay Code Assignment using the Standard Method
To assign relay code using the Standard method:
1.
Enter Programming mode.
Green
2.
Press 9 to enter Menu 9.
The left LED turns green and the right LED turns orange.
Green Orange
3.
Enter the 3-digit user slot for code assignment.
The left LED flashes green.
Green Orange
4.
Enter the assignment digit for the current user slot:
1 activates the Lock Strike relay only default
2 activates the Auxiliary relay only
3 activates the Lock Strike and Auxiliary relays
If the assignment code is valid, the left LED stops flashing.
The controller is now waiting for another slot number.
AYC-E60 Installation and Programming Manual 57
Controller Operation
5.
Do one of the following:
Press # to move to the next available user slot number.
Enter another 3-digit user slot number.
If you do not wish to continue enrolling codes, press # twice and the controller returns to Normal mode.
4.9.15.2
Relay Code Assignment using the Search Method
To assign relay code using the Search method:
1.
Enter Programming mode.
2.
Press 9 to enter Menu 9.
Green
The left LED turns green and the right LED turns orange.
3.
Enter 000 for user slot access.
The right LED flashes orange.
4.
Do one of the following:
Green Orange
Green Orange
Enter the PIN code of the Primary code belonging to the user you want to delete.
Present the user card of the Primary code belonging to the user you want to delete.
5.
Green Orange
Enter the assignment digit for the current user slot:
The left LED flashes green.
1 activates the Lock Strike relay only default
2 activates the Auxiliary relay only
3 activates the Lock Strike and Auxiliary relays
58 AYC-E60 Installation and Programming Manual
Controller Operation
If the assignment digit is valid, three beeps are heard and the controller returns to Normal mode.
If the assignment digit is invalid, a long beep sounds and the controller waits for another assignment digit to be entered.
4.9.16
PIN Code Length/Factory Default Settings
You must be very careful before using this command!
Changing the PIN code length also erases the entire memory contents, including all user and special codes, and returns all codes to their factory default settings.
To change the PIN code length:
1.
Enter Programming mode.
Green
2.
Select the desired PIN code length as follows:
00 – Returns to factory defaults and sets a 4-digit code
05 – Returns to factory defaults and sets a 5-digit code
06 – Returns to factory defaults and sets a 6-digit code
08 – Returns to factory defaults and sets a 4–8 digit code
When choosing the 4–8 option, please note that you should either enter zeros before the code, or press # at the end (for example if your code is 12345, enter either 00012345 or
12345# ).
Both LEDs flash red.
3.
Enter your 4-digit Programming code.
Red Red
If the Programming code is valid, all memory is erased. You hear three beeps and the controller returns to Normal mode.
If the Programming code is invalid, you hear a long beep and the controller returns to Normal mode without erasing the memory contents.
AYC-E60 Installation and Programming Manual 59
Controller Operation
4.9.17
Replacing a Lost Programming Code
The unit must be in Normal mode; otherwise, this does not work. Make sure that the left LED is green before proceeding.
To replace a lost Programming code:
1.
Remove power from the power supply unit.
2.
Press the REX button on the power supply unit.
3.
Apply power to the unit with REX button pressed.
4.
Release the REX button.
5.
You now have 15 seconds to program a new Programming code into the access control unit using the default code based
on the PIN code length you chose (see Table 4) before the
controller reverts to the existing code.
4.9.18
Replacing a Lost Normal/Secure Code
The unit must be in Secure mode; otherwise, this does not work. Make sure that the left LED is red before proceeding.
To replace a lost Normal/Secure code:
1.
Remove power from the power supply unit.
2.
Press the REX button on the power supply unit.
3.
Apply power to the unit with the REX button pressed.
4.
Release the REX button.
5.
You now have 15 seconds to program a new Normal/Secure code into the access control unit using the default code based
on the PIN code length you chose (see Table 4) before the
controller reverts to the existing code.
60 AYC-E60 Installation and Programming Manual
Technical Specifications
5.
Technical Specifications
Electrical Characteristics
Power Supply Type
Operating Voltage Range
Linear (recommended)
6–16 VDC
(when used as a controller, provided by the secured intelligent power supply)
Input Current Standby (12 VDC) 110 mA
Input Current Max (16 VDC) 130 mA
LED Control Input
Tamper Output
Dry contact N.O.
Open collector, active low, 32 mA max sink current
Cable Distance to Host Controller Up to 150 m (500 ft) using an 18-AWG cable
Max. Proximity Card Read
Range*
Rosslare proximity: 40 mm (1.6)
HID Prox: 40 mm (1.6 in.)
Proximity Card Modulation
Proximity Card Compatibility
Rosslare proximity/HID Prox at 125 kHz
Rosslare proximity/HID Prox cards
Card Transmit Format (Reader) Rosslare proximity cards: Wiegand 26-bit, or Clock & Data
HID cards: According to card type
Programmable PIN code formats Keypad Transmit Format
(Reader)
LED Indicators
Communication
Two tri-colored LEDs
Data1/C1, Data0/C2–open collector,
5 V termination
* Measured using a Rosslare proximity card or equivalent. Range also depends on electrical environment and proximity to metal.
AYC-E60 Installation and Programming Manual 61
Technical Specifications
Environmental Characteristics
Operating Temp. Range
Operating Humidity Range
Outdoor Usage
-22°F to 150°F (-30°C to 65°C)
0 to 95% (non-condensing)
Weather-resistant, meets IP-65, epoxy potted, suitable for indoor and outdoor use
Physical Characteristics
Size
(Height x Width x Depth)
Weight
155 x 44 x 9 mm (6.1 x 1.7 x 0.4 in.)
143 g (5.0 oz)
62 AYC-E60 Installation and Programming Manual
Declaration of Conformity
A.
Declaration of Conformity
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
AYC-E60 Installation and Programming Manual 63
Limited Warranty
B.
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the
Quick Links section on the ROSSLARE website at www.rosslaresecurity.com
.
Rosslare considers any use of this product as agreement to the
Warranty Terms even if you do not review them.
64 AYC-E60 Installation and Programming Manual
Asia Pacific, Middle East,
Africa
Rosslare Enterprises Ltd.
Kowloon Bay, Hong Kong
Tel: +852-2795-5630
Fax: +852-2795-1508 [email protected]
United States and
Canada
Rosslare Security Products, Inc.
Southlake, TX, USA
Toll Free: +1-866-632-1101
Local: +1-817-305-0006
Fax: +1-817-305-0069 [email protected]
Europe
Rosslare Israel Ltd.
22 Ha'Melacha St., P.O.B. 11407
Rosh HaAyin, Israel
Tel: +972-3-938-6838
Fax: +972-3-938-6830 [email protected]
CERT
ISO 9001
ISO 14001
0706-0960684+01
AYC-E60
Latin America
Rosslare Latin America
Buenos Aires, Argentina [email protected]
China
Rosslare Electronics (Shenzhen) Ltd.
Shenzhen, China
Tel: +86-755-8610 6842
Fax: +86-755-8610 6101 [email protected]
India
Rosslare Electronics India Pvt Ltd.
Tel/Fax: +91-20-40147830
Mobile: +91-9975768824 [email protected]
advertisement
Related manuals
advertisement
Table of contents
- 9 Introduction
- 9 Box Content
- 10 Ancillary Equipment
- 11 Installation
- 11 Mounting
- 12 Wiring
- 12 Wiring the Unit as a Reader
- 13 Wiring the Unit as a Controller
- 16 Reader Operation
- 16 General
- 17 Programming as a Reader
- 18 Entering Programming Mode
- 19 Exiting Programming Mode
- 19 Selecting Keypad Transmission Format
- 24 Selecting HID Prox Card Transmission Format
- 25 Selecting Rosslare Proximity Card Transmission Format
- 27 Changing the Programming Code
- 27 Changing the Facility Code
- 28 Setting the Backlight Behavior
- 29 Setting the Credential Format
- 29 Return to Factory Default Settings
- 30 Replacing a Lost Programming Code
- 31 Controller Operation
- 31 Normal, Secure, and Master Users
- 32 Modes of Operation
- 32 Normal Mode
- 33 Bypass Mode
- 33 Secure Mode
- 33 Changing the Modes of Operation
- 35 Auxiliary Input and Output
- 35 Door Alarms
- 35 Internal Case and Back Tamper
- 35 Lockout Feature (Keypad/Card Tamper)
- 36 REX Function
- 36 Secured Intelligent Power Supply
- 37 Programming as a Controller
- 38 Entering Programming Mode
- 38 Exiting Programming Mode
- 39 Changing Lock Strike Code
- 39 Changing Auxiliary Code
- 40 Changing the Programming Code
- 41 Changing the Normal/Secure Code
- 42 Release Time
- 43 Defining the Auxiliary Input and Output
- 49 Setting the Lockout Feature
- 50 Setting the Backlight Behavior
- 50 Selecting the Credential Format
- 51 Enrolling Primary and Secondary Codes
- 54 Deleting Primary and Secondary Codes
- 57 Relay Codes Assignment
- 59 PIN Code Length/Factory Default Settings
- 60 Replacing a Lost Programming Code
- 60 Replacing a Lost Normal/Secure Code
- 61 Technical Specifications
- 63 Declaration of Conformity
- 64 Limited Warranty