Content
Operation Notices
Precautions............................................................................................................1
Maintenance
Emergency operation ............................................................................................6
Clean and maintenance.........................................................................................6
Installation Notice
Installation dimension diagram ..............................................................................9
Safety precautions for installing and relocating the unit ................................... 10
Tools for installation .............................................................................................11
Selection of installation location ..........................................................................11
Requirements for electric connection ..................................................................12
Installation
Installation of indoor unit......................................................................................13
Check after installation ........................................................................................18
Test and operation
Test operation ......................................................................................................18
Screen Operation Guide
Parts Name ......................................................................................................... 19
Buttons on remote controller ...............................................................................21
Introduction for icons on display screen.......... ....................................................21
Introduction for buttons on remote controller .......................................................22
Introduction for special function ...........................................................................28
Operation guide ...................................................................................................30
Replacement of batteries in remote controller .....................................................30
Malfunction
Malfunction analysis ............................................................................................31
Attachment
.........................................................................35
Pipe expanding method .......................................................................................37
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If it needs to install, move or maintain the air conditioner, please contact dealer or local service center to conduct it at first. Air conditioner must be installed, moved or maintained by appointed unit. Otherwise, it may cause serious damage or personal injury or death.
Explanation of Symbols
DANGER
WARNING
CAUTION
NOTICE
Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.
Indicates important but not hazard-related information, used to indicate risk of property damage.
Indicates a hazard that would be assigned a signal word
WARNING or CAUTION.
Exception Clauses
Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
1.Damage the product due to improper use or misuse of the product;
2.Alter, change, maintain or use the product with other equipment without abiding by the instruction manual of manufacturer;
3.After verification, the defect of product is directly caused by corrosive gas;
4.After verification, defects are due to improper operation during transportation of product;
5.Operate, repair, maintain the unit without abiding by instruction manual or related regulations;
6.After verification, the problem or dispute is caused by the quality specification or performance of parts and components that produced by other manufacturers;
7.The damage is caused by natural calamities, bad using environment or force majeure.
Precautions
WARNING
Operation and Maintenance
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid electric shock.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
1
Precautions
WARNING
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause malfunction.
Do not spill water on the remote controller, otherwise the remote controller may be broken.
When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service.
●
●
●
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
●
●
Indoor unit is leaking.
If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
Do not step on top panel of outdoor unit, or put heavy objects. It may cause damage or personal injury.
2
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing the unit.
According to the local safety regulations, use qualified power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.
Including an circuit break with suitable capacity, please note the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring may result in electric shock, fire hazard or malfunction.
Please install proper power supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and grounding wire of power socket.
Be sure to cut off the power supply before proceeding any work related to electricity and safety.
3
Precautions
WARNING
Do not put through the power before finishing installation.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
The appliance shall be installed in accordance with national wiring regulations.
Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only.
The air conditioner is the first class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The appliance must be positioned so that the plug is accessible.
All wires of indoor unit and outdoor unit should be connected by a professional.
If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
4
Precautions
WARNING
For the air conditioner with plug, the plug should be reachable after finishing installation.
For the air conditioner without plug, an circuit break must be installed in the line.
If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Instructions for installation and use of this product are provided by the manufacturer.
Working temperature range
For some models:
Maximum cooling
Maximum heating
Indoor side DB/WB( ℃ )
32/23
27/-
Outdoor side DB/WB( ℃ )
50/26
24/18
NOTICE:
● The operating temperature range (outdoor temperature) for heat pump unit is
-15 ℃ ~ 50 ℃ .
5
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.
panel aux. button
WARNING:
Use insulated object to press the auto button
Clean and maintenance
WARNING
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditione r.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it.
NOTICE:
● Do not remove the panel when cleaning it.
6
Clean and maintenance
1
Open panel
Pull out the panel to a certain 3 ● Use dust catcher or water to
the water (below 45 ℃ ) to clean
it, and then put it in a shady
and cool place to dry .
2
4 panel cover tightl y .
WARNING
operation environment, clean frequency can be increased.
7
Clean and
m
aintenance
NOTICE: Checking before use-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether circuit break, plug and socket are in good condition.
4. Check whether drainage pipe is damaged.
NOTICE: Checking after use-season
1. Disconnect power supply.
Notice for recovery
1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.
8
Installation dimension diagram
Space to the wall
At least 15cm
At least 15cm
Space to the wall
At least 300cm
Space to the obstruction
9
Safety precautions for installing and relocating the unit
To ensure safety, please be mindful of the following precautions.
Warning
When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.
When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or even series safety accident.
When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running in cooling mode.Then, fully close the valve at high pressure side (liquid valve).About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant recovery should not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury.
During refrigerant recovery, make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe.
If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury.
When installing the unit, make sure that connection pipe is securely connected before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury.
Prohibit installing the unit at the place where there may be leaked corrosive gas or flammable gas.
If there leaked gas around the unit, it may cause explosion and other accidents.
Do not use extension cords for electrical connections. If the electric wire is not long enough, please contact a local service center authorized and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the wires so that their terminals receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure wire terminals may cause electric shock or fire.
10
Tools for installation
1 Level meter
4 Drill head
7 Open-end wrench
10 Vacuum pump
2 Screw driver
5 Pipe expander
8 Pipe cutter
11 Pressure meter
3 Impact drill
6 Torque wrench
9 Leakage detector
12 Universal meter
13 Inner hexagon spanner
Note:
14 Measuring tape
● Please contact the local agent for installation.
Selection of installation location
Basic requirement
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local dealer:
1. The place with strong heat sources, vapors, flammable or explosive gas, or
volatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical
equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. The appliance shall nost be installed in the laundry.
8. It’s not allowed to be installed on the unstable or motive base structure (such
as truck) or in the corrosive environment (such as chemical factory).
Indoor unit
1. There should be no obstruction near air inlet .
2. Select a location where the condensation water can be dispersed easily and won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the power socket.
4. Select a location which is out of reach for children.
5. The location should be able to withstand the weight of indoor unit and won't increase noise and vibration.
6. The appliance must be installed 2.5m above floor.
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from fluorescent lamp.
11
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
air switch.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnec-
tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
Grounding requirement
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
all poles should be connected in fixed wiring. For models with a power plug, make
sure the plug is within reach after installation
12
Installation of indoor unit
Step one: choosing installation location rm it with the client.
Step two: install wall-mounting frame
1 . Hang the wallmo unting fra m e o n the wall; a d just it in h o riz o ntal p o siti o n with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wal l with tapping screws (ST4.
2X 25 T A) and
.
Step three: open piping hole
1. Choose the position of piping hole acc ording to the direction of outlet pip e .
The
position of piping hole should be a li ttle lower than the wall-mounted frame,
shown as belo w .
QC:
Wall
Space to the wall above
150mm
Mark in the middle of it
Left
Φ55mm
Rear piping hole
Level meter
Space to the wall above
150mm
Wall
Right
Φ55mm
Rear piping hole
QD:
Wall
Space to the wall above
150mm
Mark in the middle of it
Left
Φ55mm
Rear piping hole
Level meter
Space to the wall above
150mm
Wall
Right
Φ55mm
Rear piping hole
QE:
Wall
Space to the wall above
150mm
Mark in the middle of it
Left
Φ70mm
Rear piping hole
Level meter
Space to the wall above
150mm
Wall
Right
Φ70mm
Rear piping hole
2. Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe position. In order to drain smoothly , slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5-10°.
13
Installation of indoor unit
Note:
● Pay attention to dust prevention and
take relevant safety measures when
opening the hole.
● The plastic expansion particles are
not provided and should be bought
locally.
5-10°
Indoor outdoor
Φ55 /
Φ70
Step four: outlet pipe
1. The pipe can be led out in the
direction of right, rear right, left or
rear left.
right left rear right rear left
2. When select leading out the pipe
from left or right, please cut off the
corresponding hole on the bottom
case.
left right cut off the hole
1. Aim the pipe joint at the corresponding
bellmouth.
2. Pretightening the union nut with hand.
pipe joint union nut pipe
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
14
Installation of indoor unit
torque wrench open-end wrench union nut pipe indoor pipe
4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it with tape.
Hex nut diameter Tightening torque (N.m)
Φ 6 15~20
Φ 9.52
Φ 12
Φ 16
Φ 19
30~40
4 5 ~55
60~65
70~75 insulating pipe
Step six: install drain hose
1. Connect the drain hose to the outlet pipe of indoor unit.
drain hose outlet pipe
2. Bind the joint with tape.
tape
Note:
● Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
● The plastic expansion particles are
not provided.
drain hose drain hose insulating pipe
Step seven: connect wire of indoor unit panel
1. Open the panel, remove the screw on the wiring cover and then take down the cover.
screw wiring cover
15
Installation of indoor unit
2. Make the power connection wire go through the cable-cross hole at the back of indoor unit and then pull it out from the front side.
cable-cross hole power connection wire
3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw with wire clip.
blue black brown
3 yellowgreen
Outdoor unit connection
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should be more than 3mm.
16
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
indoor unit gas pipe indoor and outdoor power cord connection pipe band liquid pipe drain hose
2. Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.
drain hose band indoor power cord
3. Bind them evenly.
4. The liquid pipe and gas pipe should be bound separately at the end.
Note:
● The power cord and control wire
can't be crossed or winding.
● The drain hose should be bound
at the bottom.
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
indoor outdoor upper hook wall pipe sealing gum lower hook of wall-mounting frame
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
17
Check after installation
Items to be checked Possible malfunction
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test?
Is water drained well?
(heating) capacity.
It may cause condensation and water dripping.
It may cause condensation and water dripping.
Is the voltage of power supply according to the voltage marked on the nameplate?
Is electric wiring and pipeline installed correctly?
It may cause malfunction or damaging the parts.
It may cause malfunction or damaging the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the speciIt may cause malfunction or damaging the parts.
Is there any obstruction in the air inlet and outlet?
The dust and sundries caused during installation are removed?
(heating) capacity.
It may cause malfunction or damaging the parts.
The gas valve and liquid valve of connection pipe are open completely?
(heating) capacit y.
Is the inlet and outlet of piping hole been covered?
It may cause insufficient cooling
(heating) capacity or waster eletricity.
Test operation
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the powe r, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, F AN and HE AT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16 ℃ , the air conditioner can’t
start cooling.
18
Parts Name
Indoor Unit air inlet panel aux.button
horizontal louver air outlet
(Display content or position may be different from above graphics, please refer to actual products) remote control
NOTICE:
Actual product may be different from above graphics, please refer to actual products.
19
Parts
N
ame
Display
For some model: cooling indicator power indicator heating indicator heating indicator cooling indicator temp.
indicator
For some model: receiver window drying indicator display drying indicator temp.
indicator power indicator receiver window
For some model: temp.
indicator heating indicator cooling indicator power indicator drying indicator
For some model: temp.
indicator display receiver window
Power indicatior display
For some model: display receiver window
For some model: temp.
indicator receiver window display
W R G
Power LED color indicator:
Green-status-ON.
Red -status-OFF.
Mode LED color indicator:
White-W-Cool Mode-
Red-R-Heat Mode-
R
W
(only for heating model)
Green-G-Dry Mode-
G temp.
indicator receiver window
W R O
Power LED color indicator:
Green-status-ON.
Red -status-OFF.
Mode LED color indicator:
White-W-Cool Mode-
Red-R-Heat Mode-
R
Orange-O-Dry Mode-
W
(only for heating model)
O
Display content or position may be different from above graphics, please refer to actual products.
2 0
Buttons on remote controller
2
4
3
1
11
9
13
10
14
4
8
2
5
WiFi
6
3
12
16
7
1
15
5
6
7
1
2
3
4
8
9
ON/OFF button
FAN button
MODE button
+/- button
TURBO button button button
CLOCK button
TIMER ON/
TIMER OFF button
TEMP button 10
11 / button
(before opening cover (after opening cover
12 I FEEL button
1 ON/OFF button
2
3
4
FAN button
MODE button
+/- button
13
14
15
16
LIGHT button
WiFi button
QUIET button
SLEEP button
Introduction for icons on display screen
Auto mode
Cool mode
Dry mode
Fan mode
Heat mode
I feel
Quiet
Operation mode
Set fan speed
Turbo mode
Send signal
Healthy mode
Scavenging function
8 ℃ heating function
Set temperature
This is a general remote controller. Some models have this function while some do not. Please refer to the actual models.
X-FAN function
Set time
TIMER ON /TIMER OFF
Clock
Sleep mode
Light
: Set temp.
Temp. display type
: Indoor ambient temp.
Child lock
Up & down swing
Left & right swing
: Outdoor ambient temp.
2 1
Introduction for buttons on remote controller
Note:
●This is a general use remote controller , it could be used for the air conditioners
with multifunction; For some function, which the model don't have, if press the
corresponding button on the remote controller that the unit will keep the original
running status.
● After putting through the power, the air conditioner will give out a sound.
Operation indicator " " is ON (red indicator, the colour is different for different
models). After that, you can operate the airconditioner by using remote controller.
● Under on status, pressing the button on the remote controller, the signal icon " "
on the display of remote controller will blink once and the air conditioner will give
out a “di” sound, which means the signal has been sent to the air conditioner.
● Under off status, set temperature and clock icon will be displayed on the display
of remote controller (If timer on, timer off and light functions are set, the corre-
sponding icons will be displayed on t h e display of remote controller at the same
time); Under on status, the display will show the corresponding set function icons.
● As for the models with functions of WiFi or wired controller, the indoor unit must
has been controlled by standard remote controller under auto mode first, and then
the function of adjustable temperature under auto mode can be realized by APP
or the wired controller.
●This remote controller can adjust the temperature under auto mode. When matching
with the unit which is without the function of adjustable temperature under auto
mode, the set temperature under auto mode may be invalid, or the displayed set
temperature on the unit is not same as that on the remote controller under auto
mode.
1
ON/OFF button
Press this button to turn on the unit. Press this button again to turn off the unit.
2
FAN button
Press this button, Auto, Low, Medium-low, Medium, Medium-high, High speed can be circularly selected. After powered on , A uto fan speed is default. Under DRY mode, Low fan speed only can be set up.
A TUO Low fan Medium-low fan Medium fan
Note:
● It’s Low fan speed under Dry mode.
●
Medium-high fan High fan
X-FAN funct i on : H old fan speed button for 2 s i n COO L or D RY mode , t h e i con “ ” i s d i splayed and t h e i ndoor fan w i ll cont i nue operat i on for a few m i nutes i n order to dry t h e i ndoor un i t e v en though you have turned off the unit. After energization, X-FAN
OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
This function indicates that moisture on e v aporator of indoor unit will be blowed after the unit is stopped to avoid mould.
22
Introduction for buttons on remote controller
● Having set X-FAN function on: After turning off the unit by pressing ON/OFF
button indoor fan will continue running for a few minutes. at low speed. In this
period, Hold fan speed button for 2s to stop indoor fan directly.
● Having set X-FAN function off: After turning off the unit by pressing ON/OFF
button, the complete unit will be off directly.
3 MODE button
Press this button, Auto, Cool, Dry, Fan, Heat mode can be selected circularly. Auto mode is default while power on. Under Heat mode, the initial value is 28
℃ ℉
Under other modes, the initial value is 25 ℃ (77 ℉ ).
AUTO COOL DRY
FAN HEAT
(only for cooling and heating unit. As for cooling only unit, it won’t have any action when it receives the signal of heating operation.)
Note: Under auto mode, temperature can be displayed;Under auto mode, set
temperature can be adjusted.
4 +/- button
Press " + " or " - " button once increase or decrease set temperature 1°C(°F).
Holding " + " or " - " button, set temperature on remote controller will change
quickly . On releasing button after setting is finished, temperature indicator
on indoor unit will change accordingly.
When setting TIMER ON, TIMER OFF or CLOCK, press " + " or " - " button to
adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons).
Note : Under auto mode, temperature can be adjusted and displayed.
5
TURBO button
Under Cool or Heat mode, press this button can turn on or turn off the Turbo function.
After the Turbo function turned on, the signal of Turbo will display. The signal will be automatically cancelled if changing the mode or fan speed.
6 button
Press this button to set left & right swing angle cycling as below:
7 button
OFF
Press this button to set swing angle, which circularly changes as below:
OFF
23
Introduction for buttons on remote controller
This remote controller is universal. If it receives threes kinds of following status, the swing angle will remain original.
If guide louver is stopped when it is swinging up and down, it will remian its present position.
indicates guide louver swings back and forth in the five places, as shown in the figure.
8 CLOCK button
Press this button, the clock can be set up, signal blink and display. Within 5 seconds, the value can be adjusted by pressing + or - button, if continuously press this button for 2 seconds above, in every 0.5 seconds, the value on ten place ofMinutewill be increased 1.
During blinking, repress the Clock button or Confirm button, signal will be constantly displayed and it denotes the setting succeeded. After powered on, 12:00 is defaulted to display and signal will be displayed. If there is signal be displayed that denotes the current time value is Clock value, otherwise is Timer value.
9
TIMER ON/TIMER OFF button
Timer On setting: Signal “ON” will blink and display, signal will conceal, the numerical section will become the timer on setting status. During 5 seconds blink, by pressing + or - button to adjust the time value of numerical section, every press of that button, the value will be increased or decreased 1 minute. Hold pressing + or button, 2 seconds later, it quickly change, the way of change is: During the initial
2.5 seconds, ten numbers change in the one place of minute, then the one place is constant, ten numbers change in the tens place of minu te at 2.5 seconds speed and carry. During 5s blink, press the Timer button, the timer setting succeeds. The
Timer On has been set up, repress the timer button, the Timer On will be canceled.
Before sett ing the Timer, please adjust the Clock to the current actual time.
One press this key to enter into TIMER OFF setup, in which case the TIMER OFF icon will blink. The method of setting is the sameas for TIMER ON.
10
TEMP button
Press this button, you can see indoor set temperature, indoor ambient temperature or outdoor ambient temperature on indoor unit’s display. The setting on remote controller is selected circularly as below: no display
When selecting " " with remote controller or no display, temperature indicator on indoor unit displays set temperature; When selecting " " with remote controller, temperature indicator on indoor unit displays indoor ambient temperature; When selecting " " with remote controller, temperature indicator on indoor unit displays outdoor ambient temperature. 3s later it will return to the setting temprature or it depends on the other received signal within 3s.
24
Introduction for buttons on remote controller
Attention: When displaying the outdoor ambient, the displaying range is 0-60 ℃
When it goes beyond the range, it keeps the threshold data (the smallest—0 ℃ and the largest 60 ℃ ).
Warm tips: When operating buttons on the cover please make sure the cover is closed completely.
Note: Outdoor temperature display is not available for some models. At that time,
indoor unit receives " " signal, while it displays indoor set temperature.
11
/ button
Press this button to achieve the on and off of healthy and scavenging functions in operation status. Press this button for the first time to start scavenging function;
LCD displays " " . Press the button for the second time to start healthy and scavenging functions simultaneously; LCD displays " " and " ". Press this button for the third time to quit healthy and scavenging functions simultaneously. Press the button for the fourth time to start healthy function; LCD display " " . Press this button again to repeat the operation above.
NOTE: This function is applicable to partial of models.
12
I FEEL button
Press this button once, to turn on the I FEEL function, then the figure of "I FEEL" will be displayed, after every press of other function button, every 200ms to send
I FEEL once, after this function started, the remote controller will send temperature to the main un it in every 10 minutes. When repress this button, this function will be turned off. When I FEEL function is turned on, the remote controller should be put within the area where indoor unit can receive the signal sent by the remote controller.
13
LIGHT button
Press this button at unit On or Off status, Light On and Light Off can be set up.
After powered on, Light On is defaulted.
14
WiFi button
Press " WiFi " button to turn on or turn off WiFi function. When WiFi function is turned on, the " WiFi " icon will be displayed on remote controller; Under status of remote controller off, press "MODE" and " WiFi " buttons simultaneously for 1s,
WiFi module will restore to factory default setting.
● This function is only available for some models.
2 5
Introduction for buttons on remote controller
15
QUIET button
Press this button, the Quiet status is under the Auto Quiet mode (display " " and "Auto" signal) and Quiet mode (display " " signal) and Quiet OFF (there is no signal of " " displayed), after powered on, the Quiet OFF is defaulted.
Under the Quiet mode (Display " " signal).
The Quiet function is only available for some models.
16
SLEEP button
Press this button, can select Sleep 1 ( ), Sleep 2 ( ), Sleep 3 ( ) and cancel the Sleep, circulate between these, after electrified, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool modes: sleep status after run for one hour, the main unit setting temperature will increase 1 ℃ , 2 hours, setting temperature increased 2 ℃ , the unit will run at this setting temperature; In Heat mode:sleep status after run for one hour, the setting temperature will decrease 1 ℃ , 2 hours, setting temperature will decrease 2 ℃ , then the unit will run at this setting temperature.
Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.
In Cool mode:
(1) When setting the initial temperature 16 ℃ -23 ℃ , after turned on Sleep function, the temperature will be increased 1 ℃ in every hour, after 3 ℃ the temperature will be maintained, after 7hours, the temperature will be decreased 1 ℃ , after that the unit will keep on running under this temperature;
(2) When setting the initial temperature 24 ℃ -27 ℃ , after turned on Sleep function, the temperature will be increased 1 ℃ in every hour, after 2 ℃ the temperature will be maintained, after 7hours, the temperature will be decreased 1 ℃ , after that the unit will keep on running under this temperature;
(3) When setting the initial temperature 28 ℃ -29 ℃ , after turned on Sleep function, the temperature will be increased 1 ℃ in every hour, after 1 ℃ the temperature will be maintained, after 7hours, the temperature will be decreased 1 ℃ , after that the unit will keep on running under this temperature;
(4) When setting the initial temperature 30 ℃ , under this temperature setting, after
7hours, the temperature will be decreased 1 ℃ , after that the unit will keep on running under this temperature;
In Heat mode:
(1) Under the initial presetting temperature 16 ℃ , it will run under this setting temperature all along.
2 6
Introduction for buttons on remote controller
(2) Under the initial presetting temperature17 ℃ -20 ℃ , after Sleep function started up, the temperature will decrease 1 ℃ in every hour, after 1 ℃ decreased, this temperature will be maintained.
(3) Under the initial presetting temperature 21 ℃ -27 ℃ , after Sleep function started up, the temperature will decrease 1 ℃ in every hour, after 2 ℃ decreased, this temperature will be maintained.
(4) Under the initial presetting temperature 28 ℃ -30 ℃ , after Sleep function started up, the temperature will decrease 1 ℃ in every hour, after 3 ℃ decreased, this temperature will be maintained.
Sleep 3 - the sleep curve setting under Sleep mode by DIY:
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote controller enters into user individuation sleep setting status, at this time, the time of remote controller will display "1hour", the setting temperature "88" will display the corresponding temperature of last setting sleep curve and blink (The first entering will display according to the initial curve setting value of original factory);
(2) Adjust "+" and "-" button, could change the corresponding setting temperature, after adjusted, press "Trubo" button for confirmation;
(3) At this time, 1hour will be automatically increased at the timer postion on the remote controller, (that are "2hours" or "3hours" or "8hours"), the place of setting temperature "88" will display the corresponding temperature of last setting sleep curve and blink;
(4) Repeat the above step (2)~(3) operation, until 8hours temperature setting finished, sleep curve setting finished, at this time, the remote controller will resume the original timer display; temperature display will resume to original setting temperature.
Sleep3 - the sleep curve setting under Sleep mode by DIY could be inquired:
The user could accord to sleep curve setting method to inquire the presetting sleep curve, enter into user individuation sleep setting status, but do not change the temperature, press "Turbo" button directly for confirmation.
Note: In the above presetting or enquiry procedure, if continuously within10s, there is no button pressed, the sleep curve setting status will be automatically quit and resume to display the original displaying. In the presetting or enquiry procedure, press "ON/OFF" button, "Mode" button, "Timer" button or "Sleep" button, the sleep curve setting or enquiry status will quit similarly.
2 7
Introduction for special function
About AUTO RUN
When AUTO RUN mode is selected, the unit will be in accordance with the room temp. automatically to select the suitable running method and to make ambient comfortable.
About turbo function
If start this function, the unit will run at super-high fan speed to cool or heat quickly so that the ambient temp. approachs the preset temp. as soon as possible.
About lock
Press + and - buttons simultaneously to lock or unlock the keyboard. If the remote controller is locked, the icon will be displayed on it, in which case, press any button, the mark will flicker for three times. If the keyboard is unlocked, the mark will disappear.
About swing up and down
1. Press swing up and down button continuously more than 2s, the m ain unit will swing backand forth from up to down , and then loosen the button, the unit will stop swing and present position of guide louver will be kept immediately.
2. Under swing up and down mode, when the status is switched from off to , if press this button again 2s later, status will switch to off status directly; If press this button again within 2s, the change of swing status will also depend on the circulation sequence stated above.
About swing left and right
1. Press swing left and right button continuously more than 2s, the main unit will swing back and forth from left to right, and then loosen the button, the unit will stop swing and present position of guide louver will be kept immediately.
2. Under swing left and right mode, when the status is switched from off to , if press this button again 2s later, status will switch to off status directly; if press this button again within 2s, the change of swing status will also depend on the circulation sequence stated above.
2 8
Introduction for special function
About switch between Fahrenheit and Centigrade
Under status of unit off, press MODE and - buttons simultaneously to switch ℃ and ℉ .
Combination of "TEMP" and "CLOCK" buttons:
About Energy - saving Function
Press “TEMP” and “CLOCK” simultaneously in COOL mode to start energy-saving function. Nixie tube on the remote controller displays “SE”. Repeat the operation to quit the function.
Combination of "TEMP" and "CLOCK" buttons:
About 8 ℃ Heating Function
Press “TEMP” and “CLOCK” simultaneously in HEAT mode to start 8 ℃ Heating Function
Nixie tube on the remote controller displays “ ” and a sele cted temperature of “8 ℃ ”.
(46 ℉ if Fahrenheit is adopted). Repeat the operation to quit the function.
About Quiet function
When quiet function is selected:
1. Under cooling mode: indoor fan operates at notch 4 speed. 10 minutes later or when indoor ambient temperature≤28 ℃ , indoor fan will operate at notch 2 speed or quiet mode according to the comparison between indoor ambinet temperature and set temperature.
2. Under heating mode: indoor fan operates at notch 3 speed or quiet mode according to the comparison between indoor ambient temperature and set temperature.
3. Under dry, fan mode: indoor fan operates at quiet mode.
4. Under auto mode: the indoor fan operates at the auto quiet mode according to actual cooling, heating or fan mode.
About Sleep function
Under the Fan 、 Dry and Auto mode, the Sleep function cannot be set up, Select and enter into any kind of Sleep mode, the Quiet function will be attached and stared, different Quiet status could be optional and turned off.
2 9
Operation guide
General operation
1. After powered on, press ON/OFF button, the unit will start to run. (Note: When it is powered on, the guide louver of main unit will close automatically.)
2. Press MODE button, select desired running mode.
3. Pressing + or - button, to set the desired temperature.
4. Pressing FAN button, set fan speed, can select AUTO FAN,
LOW, MEDIUM-LOW, MEDIUM, MEDIUM-HIGH and HIGH.
5. Pressing and button, to select the swing.
3
2
1
WiFi
4
Optional operation
1. Press SLEEP button, to set sleep.
2. Press TIMER ON and TIMER OFF button, can set the scheduled timer on or timer off.
3. Press LIGHT button, to control the on and off of the displaying part of the unit (This function may be not available for some units).
4. Press TURBO button, can realize the ON and OFF of
TURBO function.
4
3 WiFi
Replacement of batteries in remote controller
1. Press the back side of remote controller marked the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
reinstall battery remove
Cover of battery box
NOTICE
● During operation, point the remote co ntrol signal sender at the receiving window on indoor unit.
● The distance between signal sender and receiving window should be no
● Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone; remote controller should be close to indoor unit during operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the batteries.
● If the display on remote controller is fu z zy or there’s no display, please replace batteries.
30
2
1
5
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
Phenomenon Check items Solution
Indoor unit can’t receive remote controller’s signal or remote controller has no action.
● Whether it's interfered severely
(such as static electricit y , stable
voltage)?
● Whether remote controller is
within the signal receiving
range?
● Pull out the plug. Reinsert
the plug after about 3min, and
then turn on the unit again.
● Signal receiving range is 8m.
● Whether there are obstacles?
● Whether remote controller is
pointing at the receiving
window?
● Is sensitivity of remote contro-
ller low; fuzzy display and no
display?
● No display when operating
remote controller?
● Fluorescent lamp in room?
● Remove obstacles.
● Select proper angle and point
the remote controller at the re-
ceiving window on indoor unit.
● Check the batteries. If the
power of batteries is too low,
please replace them.
● Check whether remote cont-
roller appears to be damaged.
If yes, replace it.
● Take the remote controller
close to indoor unit.
No air emitted from indoor unit
and then try it again.
● Air inlet or air outlet of indoor
unit is blocked?
● Under heating mode, indoor
temperature is reached to set
temperature?
● Heating mode is turned on just
now?
● Eliminate obstacles.
● After reaching to set temper-
ature, indoor unit will stop bl-
owing out air.
● In order to prevent blowing
out cold air, indoor unit will be
started after delaying for sev-
eral minutes, which is a nor-
mal phenomenon.
3 1
Malfunction analysis
Phenomenon
Air conditioner can’t operate
Check items
● Whether the function setting
for remote controller is
correct?
Solution
● Power failure?
● Is plug loose?
● Wait until power recovery.
● Reinsert the plug.
● Air switch trips off or fuse is
burnt out?
● Wiring has malfunction?
● Ask professional to replace
air switch or fuse.
● Ask professional to replace it.
● Unit has restarted immediately
after stopping operation?
● Wait for 3min, and then turn
on the unit again.
● Reset the function.
Mist is emitted from indoor unit’s air outlet
● Indoor temperature and hum-
idity is high?
● Because indoor air is cooled
rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will
disappear.
Set temperature can’t be adjusted
● Y our required temperature
exceeds the set temperature
range?
● Set temperature range:
16 ℃ ~30 ℃ .
Cooling
(heating) effect is not good.
● V oltage is too low?
● Wait until the voltage
resumes normal.
● Filter is dirty?
● Set temperature is in proper
range?
● A djust temperature to proper
range.
● Door and window are open?
● Close door and window.
3 2
Malfunction analysis
Phenomenon Check items Solution
Odours are emitted
● Whether there ’s odour source,
such as furniture and cigarette,
etc.
● Eliminate the odour source.
Air conditioner operates abno rmally
● Whether there ’s interference,
such as thunder, wireless
devices, etc.
“ W ater noise
● Disconnect powe r, put back
power, and then turn on the
unit again.
● Air conditioner is turned on or
turned off just now?
● The noise is the sound of
the unit, which is a normal
phenomenon.
Cracking noise
● Air conditioner is turned on or
turned off just now?
● This is the sound of friction
caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.
3 3
Malfunction analysis
Error Code
● When air conditioner status is abnorm al, temperature indica tor on indoor unit will
ation of error code.
Error code
E1
Troubleshooting
It can be eliminated after restarting the unit. If not, please
E5
It can be eliminated after restarting the unit. If not, please
E6
It can be eliminated after restarting the unit. If not, please
E8
It can be eliminated after restarting the unit. If not, please
H3
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
H6
C5
F1
F2
F0
Note: If there're other error codes, please contact qualified professionals for service.
WARNING
■ When below phenomenon occurs, pl ease turn off air conditioner and discon-
for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Air switch trips o ff frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ If the air conditioner operates under a bnormal conditions, it may cause
3 4
Configuration of connection pipe
1. Standard length of connection pipe
● 5m, 7.5m, 8m.
2.Min. length of connection pipe is 3m.
3.Max. length of connection pipe.
Max length of connection pipe
Cooling capacity
Max length of connection pipe
Cooling capacity
Unit: m
Max length of connection pipe
5000Btu/h
(1465W)
7000Btu/h
(2051W)
9000Btu/h
(2637W)
12000Btu/h
(3516W)
15
15
15
20
24000Btu/h
(7032W)
28000Btu/h
(8204W)
36000Btu/h
(10548W)
42000Btu/h
(12306W)
25
30
30
30
18000Btu/h
(5274W)
25
48000Btu/h
(14064W)
30
4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each additional 5m of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe ×
additional refrigerant charging amount per meter
● Basing on the length of standard pipe, add refrigerant according to the
requirement as shown in the table. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See the
following sheet.
3 5
Configuration of connection pipe
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Diameter of connection pipe
Liquid pipe(mm) Gas pipe(mm)
Outdoor unit throttle
Cooling only(g/m) Cooling and heating(g/m)
Φ6
Φ6 or Φ9.52
Φ12
Φ16
Φ19
Φ22.2
Φ9.52 or Φ12
Φ16 or Φ19
Φ19 or Φ22.2
Φ25.4 or Φ31.8
_
_
15
15
30
60
250
350
20
50
120
120
250
350
3 6
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:
A: Cut the pipe
● Confirm the pipe length according to
the distance of indoor unit and
outdoor unit.
● Cut the required pipe with pipe cutte r .
pipe
E: Expand the port
● Expand the port with expande r .
expander hard mold pipe pipe cutter leaning
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into
the pipe.
pipe shaper downwards uneven burr
C: Put on suitable insulating pipe
D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve;
install the union nut on the pipe.
union pip e
Note:
● "A" is different according to the
diamete r , please refer to the sheet
below:
Outer diameter
(mm)
Φ6 - 6.35(1/4")
Φ9.52(3/8")
Φ12-12.7(1/2")
Φ15.8-16(5/8")
Max
A(mm)
Min
1.
3
1.
6
1.8
2.4
0.7
1.0
1.0
2.2
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the
port again according to the steps
above.
smooth surface improper expanding pipe leaning damaged surface the length is equal crack
3 7
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI
Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070
Tel: (+86-756) 8522218
Fax: (+86-756) 8669426
E-mail: [email protected]
Web: www.gree.com
600005060396