(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

109

IMPORTANT

SAFETY RULES

Read, understand, and follow all instructions carefully before installing and using this product.

Krystal Clear™

Model 633T

Filter Pump

For illustrative purposes only.

Don’t forget to try these other fine Intex products: pools, pool accessories, inflatable pools and in-home toys, airbeds and boats available at fine retailers or visit our website.

Due to a policy of continuous product improvement, Intex reserves the right to change specifications and appearance, which may result in updates to the instruction manual without notice.

IMPORTANT!

DO NOT RETURN PRODUCT TO STORE

To purchase parts and accessories or to obtain non-technical assistance, Visit

www.intexcorp.com

For technical assistance and missing parts call us toll-free (for U.S. and Canadian Residents):

1-800-234-6839

Monday through Friday, 8:30am to 5:00pm Pacific Time

109-***-R0-2005

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English 109

TABLE OF CONTENTS

Warnings

..........................................................................

3

Parts Reference

..............................................................

4-5

Setup Instructions

..........................................................

6-9

Operating Instructions

...................................................

10

Operating Time Table

......................................................

11

Pool Care and Chemicals

...............................................

12-13

Long Term Storage

.........................................................

13

Troubleshooting Guide

...................................................

14

Common Pool Problems

................................................

15

General Aquatic Safety

..................................................

16

Limited Warranty

.............................................................

17

SAVE THESE INSTRUCTIONS

Page 2

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

IMPORTANT SAFETY RULES

Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.

READ AND FOLLOW ALL INSTRUCTIONS

WARNING

• To reduce the risk of injury, do not permit children to use this product. Always supervise

children and those with disabilities.

• Children must stay away from this product and electrical cord(s).

• Assembly and disassembly by adults only.

• Risk of electric shock. Connect only to a grounding type receptacle, this product is provided

with a ground-fault circuit interrupter. If replacement of the plug or cord is needed, use only

identical replacement parts.

• Always unplug this product from the electrical outlet before removing, cleaning, servicing or

making any adjustment to the product.

• The unit is provided with a ground-fault circuit interrupter (GFCI). To test the GFCI, push the

test button. The GFCI should interrupt power. Push the reset button, power should be restored.

If the GFCI fails to operate in this manner. The GFCI is defective. If the GFCI interrupts power

to the pump without the test button being pushed, a ground current is flowing, indicating the

possibility of an electric shock. Do not use this pump. Disconnect the pump and have the

problem corrected by a qualified service representative before using.

• Do not bury the electrical cord. Locate the cord where it will not be damaged by lawn mowers,

hedge trimmers and other equipment.

• To reduce the risk of electric shock, replace damaged cord immediately. Use a qualified

electrician to replace the cord.

• To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or

converter plugs to connect unit to electric supply; provide a properly located outlet.

• Do not attempt to plug in or unplug this product while standing in water or when your hands are

wet.

• Do not use an appliance leakage current interrupter (ALCI) in place of a GFCI since the ALCI

will not protect people.

• Position this product away from pool, so as to prevent children from climbing on it and access

the pool.

• Make sure the electrical parameters indicated on the product correspond to the local mains

voltage before you connect the unit.

• This product is intended to be used only for the purposes described in the manual!

FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN PROPERTY

DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR OTHER SERIOUS

INJURY OR DEATH.

CAUTION

This product is for use with storable pools only. Do not use with permanently-installed pools. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.

To reduce the risk of electric shock the pool must be installed no closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer than 5 feet (1.5 m) from the pool.

These product warnings, instructions and safety rules provided with the product represent some common risks of water recreation devices and do not cover all instances of risk and danger. Please use common sense and good judgement when enjoying any water activity.

109

SAVE THESE INSTRUCTIONS

Page 3

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

PARTS REFERENCE

Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts.

109

1

4

5

2

3

6

7

8

17

3 2

17

NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale.

REF. NO.

1

DESCRIPTION

THREADED FILTER HOUSING COLLAR

2

3

AIR RELEASE VALVE/SEDIMENT RELEASE VALVE

VALVE O-RING

6

7

4

5

8

FILTER HOUSING COVER

FILTER HOUSING O-RING

FILTER CARTRIDGE

AIR RELEASE VALVE B (WITH O-RING)

PUMP HOSE WITH NUTS

1

1

1

1

2

QTY.

1

2

2

SPARE PART NO.

10491

10460

10264

10490

11330

29005

10725

11009

When ordering parts, be sure to quote the model number and part numbers.

No tools are required for the assembly.

SAVE THESE INSTRUCTIONS

Page 4

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

PARTS REFERENCE (continued)

Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts.

Parts shown on this page are supplied with the pool package and are shown here for assembly purposes only.

*

18

INLET

11

12 13 19 15

109

9

*

10

13 14

16

OUTLET

11 12

9

10

NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale.

REF. NO.

9*

10*

11*

12*

13*

14*

15*

16*

17

18*

19*

20*

DESCRIPTION

PLUNGER VALVE (#10 & #11 INCLUDED)

HOSE O-RING

STEP WASHER

STRAINER NUT

FLAT STRAINER RUBBER WASHER

THREADED STRAINER CONNECTOR

ADJUSTABLE POOL INLET JET NOZZLE

STRAINER GRID

HOSE O-RING

AIR JET VALVE

INLET THREADED AIR CONNECTOR

AIR JET VALVE CAP (NOT SHOWN)

1

1

1

2

1

1

1

2

2

QTY. SPARE PART NO.

2 10747

10262

10745

10256

10255

10744

12369

10253

10712

12363

12371

12373

*

If this pump was not purchased as part of a pool set, the above parts can be ordered at www.intexcorp.com if needed.

When ordering parts, be sure to quote the model number and part numbers.

SAVE THESE INSTRUCTIONS

Page 5

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English 109

POOL OUTLET - STRAINER & PLUNGER VALVE SETUP (optional)

The strainer grid prevents large objects from jamming and/or damaging the filter pump.

The plunger valve assembly prevents water from flowing into the filter pump while the filter cartridge is being placed or cleaned. If your pool has an inflatable top ring, install the strainer, nozzle and plunger valve before inflating the pool liner top ring. The parts numbers here onward, refer to the parts depicted in the Parts List section of this manual.

To install, do the following:

1. In a counter-clockwise motion unscrew plunger valve union from the threaded connector (see drawing 1) .

Be careful not to lose the step rubber

washer . Place the plunger valve on the ground in a safe place.

2. In a counter-clockwise motion unscrew the strainer nut (12) from the threaded

connector . Leave the flat

washer on the connector (14) .

3. Install the strainer and plunger valve at the lower position of pool outlet (marked "+").

From the inside of the pool liner insert connector into one of the pre-cut holes with the washer remaining on the connector to be placed against the inside of the liner wall.

4. Before assembly, lubricate the threads with a petroleum jelly. Then, with the flat side of the strainer nut (12) facing the outside wall of the liner in a clockwise motion screw the strainer nut (12) back onto the threaded connector (14) (see

5. Finger tighten the strainer nut (12) onto the threaded connector (14) .

6. Grasp the plunger valve assembly. Make sure the step washer (11) is in place.

7. In a clockwise motion screw the plunger

valve back onto the threaded

connector .

8. In a clockwise motion turn the plunger valve handle to close position. Ensure the plunger valve is securely closed. This will prevent water from flowing out during filling of the pool (see drawing 4) .

12

2

2

13 14

1

INSIDE

LINER WALL

1

16

1

2

3

4

INSIDE

LINER WALL

SAVE THESE INSTRUCTIONS

Page 6

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

POOL INLET - NOZZLE & PLUNGER VALVE SETUP (optional)

109

1. In a counter-clockwise motion unscrew plunger valve union from the inlet threaded air

connector (see drawing 5) . Be careful not to lose the step rubber washer (11) . Place the plunger valve on the ground in a safe place.

2. In a counter-clockwise motion unscrew the nut from the inlet threaded air

connector Leave the flat washer (13) on connector .

3.

Install the nozzle and plunger valve at the upper position of the pool inlet. From the inside of the pool liner insert the nozzle union

(15 & 19) into one of the pre-cut holes with the washer remaining on the connector to be placed against the inside of the liner wall.

4. Before assembly, lubricate the threads with a petroleum jelly. Then, with the flat side of the nut facing the outside wall of the liner in a clockwise motion screw the strainer

nut back onto the inlet threaded air

connector .

5. Finger tighten the adjustable pool inlet jet

nozzle and the strainer nut (12) onto the inlet threaded air connector (19) .

6. Grasp the plunger valve assembly. Make sure the step washer (11) is in place.

7. Screw the air jet valve (18) over the inlet threaded air connector (19). NOTE: Make sure the air jet valve is securely tighten and facing up. In a clockwise motion screw the plunger valve union back onto the inlet threaded air connector (19) (see drawing 7) .

8. In a clockwise motion turn the plunger valve handle to close position. Ensure the plunger valve is securely closed. This will prevent water from flowing out during filling of the pool

(see drawing 8) .

9.

Adjust the direction of the nozzle head pointing away from the pool outlet for a better result .

10. The pool liner is now ready to be filled with water. Consult the above-ground-pool owner’s manual for the filling instructions.

12

2

5

1

INSIDE LINER

WALL

6

13 19 15

18

1

7

2

8

INSIDE

LINER WALL

9

POOL

WATER

FLOW

SAVE THESE INSTRUCTIONS

Page 7

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

FILTER PUMP HOSE CONNECTION SETUP

1. Remove the Krystal Clear™ filter pump and hoses from the packaging.

2. Place the filter pump in such a manner, that you can easily assemble the hose (8) connections to the plunger valve.

Note: Some regional regulations may require the filter pump to be mounted on a stationary platform. There are two mounting holes located in the pump base for this reason. Consult your local authorities for filter-pump mounting requirements.

3. Grasp the two pump hoses (8) and connect the hose nuts to the filter pump.

4. In a counter-clockwise motion unscrew the threaded filter housing collar (1) from the filter housing. Place it in a safe place.

5. The Filter Pump is an airtight system. In a counter-clockwise motion turn both air release

valves 1 - 2 turns to open.

DO NOT remove air release valves as water will expel with force if the motor is turned on and injury may occur.

6. Grasp and remove the filter housing cover (4) . Check to see if a cartridge is inside the housing. If yes, replace the cover, finger tighten the housing collar (1) back onto the filter

housing.

7. Gently finger tighten the sediment release valve located at the bottom of the housing to be sure that water does not leak out.

8. When the pool is filled connect the hose from the bottom of the filter housing to the highest strainer assembly. You will find the hose connection at the bottom of the plunger valve assembly. Use the hose nut to attach the hose.

9. Connect the second hose which is fixed to the middle of the motor housing to the remaining liner connection.

AIR RELEASE

VALVE

MOTOR

HOUSING

FILTER HOUSING

COVER

INLET THREADED AIR

CONNECTOR

AIR JET VALVE

WATER LEVEL

PLUNGER VALVE

ASSEMBLY

HOSE NUT

ADJUSTABLE POOL

INLET JET NOZZLE

OUTLET HOSE

FILTER HOUSING

COLLAR

FILTER CARTRIDGE

INSIDE

HOSE O-RING

W A T ER F

L OW

A

W

E

T

R

F

L

O

W

THREADED

STRAINER

CONNECTOR

INSIDE LINER

WALL

109

HOSE O-RING

INLET HOSE

POWER CORD

OUTSIDE

LINER WALL

(ILLUSTRATION NOT TO SCALE)

SAVE THESE INSTRUCTIONS

Page 8

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

FILTER PUMP HOSE CONNECTION SETUP (continued)

109

For Pools with Dual Suction Outlets Configuration:

In order to comply with the requirement of the Virginia Graeme Baker Act (for USA and Canada), your pool is designed with dual suction outlets and one inlet fittings. Parts in grey highlight on this page are supplied with the pool set package and are shown here for assembly purposes only. If this pump was purchased as part of a pool set, refer to the pool owner’s manual for more details.

(ILLUSTRATION NOT TO SCALE)

WARNING

Position this product away from the pool, so as to prevent children from climbing on it and accessing the pool.

SAVE THESE INSTRUCTIONS

Page 9

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

OPERATING INSTRUCTIONS

1. Make sure the filter pump is switched off. The switch is located on the motor housing.

2.

Connect the power cord to a GFCI protected electrical outlet.

WARNING

Risk of electric shock. Connect this product only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI.

IMPORTANT

To prevent air lock, open the lower plunger valve (connected inlet hose) first and then the upper plunger valve (connected outlet hose). Open the air release valve, wait until water starts to flow out of the air release valve, close air release valve.

3 .

Turn both plunger valve handles fully counter-clockwise until they stop. This opens the valve, allowing water to flow into the filter pump.

4 . With water flowing into filter pump, the water pressure will allow the air trapped inside to escape from the air release valves (2 & 7).

When all the air has escaped water will flow out of the valves (2 & 7).

When this occurs gently finger tighten the valves (2 & 7) in a clockwise direction.

5. To operate the filter pump on “TIMER” mode:

A. Plug the power cord into the electrical outlet and set the timer dial to the desired operating hours (see Fig. 10) . See the “Operating Time Table” for the required operating hours related to each pool size.

B. The filter pump is now filtering the water and will stop after the operating hours are completed. The built-in timer will now operate for the number of hours selected at the same time each day.

C. Operating hours can be re-adjusted if necessary. Follow step A – B.

To operate the filter pump manually (without the “TIMER” mode):

A. Turn on the pump by setting the dial to “ ” position, the filter pump is now filtering the water.

B. To turn off the pump, set the dial to “ ” position.

109

: OFF

: ON (without the Timer)

2 / 4 / 6 / 8 / 12 : Timer operating time (hours)

FIG 10

6 .

Never put pool chemicals directly into the filter pump. This may damage the pump and void

SAVE THESE INSTRUCTIONS

Page 10

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

OPERATING TIME TABLE

This table shows the required operating time for average use of the filter pump with AGP's.

The filter pump running time should be 1 hour longer than the required operating time of the

Saltwater System.

Pool Size

Water Capacity (Calculated at 90% for Frame

Pool and 80% for Easy Set & Oval Pool)

(Gals) (Liters)

Recommend operating hours per day

(Hours)

INTEX ABOVE GROUND P OOLS (AGP’s)

18’ x 42” (549cm x 107cm)

EASY SET®

POOL

18’ x 48” (549cm x 122cm)

4,786 18,115 4

5,455 20,647 4

CIRCULAR

METAL FRAME

POOL

ULTRA/XTR

FRAME

POOL

18’ x 48” (549cm x 122cm)

24’ x 52” (732cm x 132cm)

16' x 48" (488cm x 122cm)

18’ x 48” (549cm x 122cm)

18’ x 52” (549cm x 132cm)

20’ x 48”

22’ x 52” (671cm x 132cm)

24'x52"

GRAPHITE GRAY

PANEL POOL

SET™

OVAL FRAME

POOL

26’ x 52” (792cm x 132cm)

15’8” x 49”

16'8" x 49" (508cm x 124cm)

18'8" x 53" (569cm x 135cm)

20’ x 12’ x 48” (610cm x 366cm x 122cm)

15’ x 9’ x 48”

RECT. ULTRA

FRAME POOL

18’ x 9’ x 52” (549cm x 274cm x 132cm)

20’ x 10 x 52”

24’ x 12’ x 52” (732cm x 366cm x 132cm)

32’ x 16’ x 52” (975cm x 488cm x 132cm)

6,423 24,311 4

12,481 47,241 6

5,061 19,156 4

6,423 24,311 4

6,981 26,423 4

7,947 30,079 4

10,472 39,637 6

12,481 47,241 6

14,667 55,515 8

4,440 16,805 4

5,061 19,156 4

6,981 26,423 4

4,393 16,628 4

3,484 13,187 2

4,545 17,203 4

5,611 21,238 4

8,403 31,805 4

14,364 54,368 8

109

SAVE THESE INSTRUCTIONS

Page 11

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

POOL CARE AND CHEMICALS

• All pools require care to keep the water clear and hygienically clean. With proper chemical control, your filter will help attain this objective. Consult your pool supply dealer for instructions regarding the proper use of chlorine, algaecide and other chemical agents required for sparkling clear water.

• Keep pool chemicals away from children.

• Do not replenish chemicals in pool while pool is occupied. Skin or eye irritations could

occur.

• Daily pH checking and chemical treatment of the water is very important and can not be overemphasized. Chlorine, algaecide and maintenance of proper pH levels are required when filling the pool as well as during the season. Consult your local swimming pool supply store for instructions.

• The season's first filling of the pool may have brackish water requiring extra water additives and extra filter changes. Do not allow swimming in pool until the pH level is balanced. Consult your local swimming pool supply store for instructions.

• Keep spare filter cartridges on hand. Replace cartridges every two weeks.

• Chlorinated water may damage lawns, gardens or shrubbery as children play in the pool and splash water outside the pool. Lawn areas underneath the pool liner will be destroyed.

Note that some types of grass may grow through the liner.

• Filter run time depends on pool size, weather and usage level. Experiment with various run times so as to produce clean clear water.

CAUTION

Concentrated chlorine solutions may damage the pool liner. Always follow the chemical manufacturer’s directions, and the health and hazard warnings.

109

CLEANING OR REPLACING FILTER CARTRIDGES

It is recommended that the filter cartridge be replaced at least every 2 weeks.

1.

Make sure the filter pump is turned off, then disconnect the power cord from the electrical

outlet.

2 . Turn both plunger valve handles fully clockwise until they stop. This closes the valve, prevents the water from flowing out of the pool.

3.

Gently turn the top air release valve once or twice in a counter-clockwise direction. The housing cover can now be easily removed.

4. In a counter-clockwise direction remove the filter housing collar (1). Place it in a safe

location.

5. Remove the housing cover (4).

6.

Now remove the used filter cartridge.

SAVE THESE INSTRUCTIONS

Page 12

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

CLEANING OR REPLACING FILTER CARTRIDGES (continued)

7. Examine the inside of the filter housing.

8. If dirt or sediment is located on the bottom of the housing then:

A.

In a counter-clockwise motion gently unscrew and remove the sediment valve (2)

located at the bottom of the housing. Place it in a safe place.

B.

With a bucket of water or a garden hose pour water into the housing flushing out the

sediment.

C.

Screw back the sediment valve (2) in a gentle clockwise motion. Do not over-tighten.

9. Place a new cartridge filter in the housing.

10. Return the housing cover (4) to its position and in a clockwise direction rescrew the housing

collar onto the filter housing.

11. Turn both plunger valve handles fully counter-clockwise until they stop. This opens the valve, allowing water to flow into the filter pump.

12.

When the trapped air has escaped through the air release valve gently retighten the valve (2) in a clockwise direction.

13. Reconnect the power cord.

14. Turn on the pump.

LONG TERM STORAGE

1. Before emptying your pool for long term storage, or relocation, be sure the water is directed towards an acceptable drain water receptacle away from the house. Check local regulations for specific directions regarding disposal of swimming pool water.

2.

Disconnect power cord from electrical outlet.

3 . Now, drain the pool.

4.

When the pool is empty, disconnect all hoses from pump and plunger valves and remove the strainers from the pool wall.

5.

Drain all water from the filter pump.

6.

Leave filter pump pieces & hoses outside to thoroughly air dry.

7 . Remove both plunger valves from the connectors (14 & 19) . Be careful not to lose the step washer .

8.

Coat the following O-rings and washers with petroleum jelly for long term storage:

• Air release valve & sediment O-rings (3) .

• Filter housing cover O-ring (5).

• Pump hose O-rings (10) .

• Strainer valve assembly step washers (11) .

• Flat strainer rubber washers (13) .

9.

Discard the used filter cartridge. Put aside 1 or 2 new cartridges for next season’s use.

10.

It is best to place all dry pieces in the original packaging for storage or placethem in an airtight plastic bag.

11. Store the unit and accessories in a dry place. The storage's temperature should be controlled, between 32 degrees Fahrenheit (0 degrees Celsius) and 104 degrees

Fahrenheit (40 degrees Celsius) storage location.

IMPORTANT

It is best to store away your poolsystem in its original packaging.

109

SAVE THESE INSTRUCTIONS

Page 13

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English 109

TROUBLESHOOTING GUIDE

TROUBLE CAUSE SOLUTION

FILTER MOTOR

FAILS TO START

FILTER DOESN’T

CLEAN POOL

FILTER DOESN’T

PUMP WATER OR

THE WATER FLOW IS

VERY SLOW

PUMP DOESN’T

WORK

TOP COVER

LEAKING

HOSE LEAKING

AIR LOCK

INLET TREADED

AIR CONNECTOR /

AIR JET VALVE

LEAKING

• The motor is not plugged in.

• The GFCI circuit breaker

• Motor too hot and overload

protection shut motor off.

• Improper chlorine or pH levels.

• Filter cartridge is dirty.

• Damaged cartridge.

• Excessively dirty pool.

• The strainer screen is restricting

the water flow.

• Clogged inlet or discharge.

• An air leak on the intake line.

• Scale or buildup on cartridge.

• Excessively dirty pool.

• Dirty filter cartridge.

• The nozzle and strainer

connection are reversed.

• Inlet threaded air connector

connected to the wrong hole on

• Low water level.

• Strainer screen plugged up.

• An air leak on the intake hose.

• Faulty motor or the impeller is

jammed.

• An air lock inside the cartridge

chamber.

• Hose nuts are not well-fitted.

• Hose o-ring dislodged when

connecting the hose.

• Hose broken.

• There’s air trapped in the

pump housing and inlet hose.

• The inlet and outlet hoses

connection are reversed.

• Plunger valve not well-fitted.

• Air jet valve is not tight and

• Air jet valve internal seal blocked.

• Air jet valve internal seal dirty.

• Air jet valve broken.

• Filter cord must be plugged into a 3 wire

outlet that is protected by a Class A

Ground Fault Circuit Interrupter.

• Reset circuit breaker. If circuit breaker trips

repeatedly, your electrical system may

have a defect. Turn off circuit breaker and

call an electrician to correct the problem.

• Let motor cool down.

• Adjust the chlorine and pH level. Consult your

local swimming pool supply stores.

• Clean or replace cartridge.

• Check the cartridge for holes. Replace if damaged.

• Operate the filter for longer periods.

• Clean the strainer screen at the inlet.

• Clear any obstructions in the intake hose by

discharging it inside pool wall.

• Tighten hose nuts, check hoses for damage,

check pool water level.

• Clean cartridge more often.

• Clean inside the plunger valve.

• Pull valve handle to full upright position.

• Install the nozzle at the upper position of pool

inlet, and the strainer at the lower position of

• Make sure the inlet threaded air connector is

connected to the pool inlet upper hole.

• Fill pool to correct water level.

• Clean strainer screens at pool inlet.

• Tighten hose nuts, check hose for damage.

• Clear any sticks or leaves in the intake hose.

• Turn and pull valve handle to full upright position.

• O-ring missing.

• Cover or air release valve are not tight.

• Remove cover & check for O-ring.

• Tighten cover or valve (Manually).

• Tighten or reinstall hose nut.

• Put the o-ring back into the groove.

• Replace a new hose.

• Open air release valve, wait until water starts to

flow out of the valves, then close it.

• The lower position of pool outlet connects to filter

pump water inlet. The upper position of pool inlet

connects to filter pump water outlet.

• Tighten or reinstall plunger valve.

• Tighten air jet valve and make sure it’s

• Turn pump ON and run for few seconds, then turn

OFF, repeat 3 times.

• Remove air jet valve, flush dirt out with water and

replace valve back.

• Replace a new air jet valve.

SAVE THESE INSTRUCTIONS

Page 14

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English 109

COMMON POOL PROBLEMS

PROBLEM DESCRIPTION CAUSE SOLUTION

ALGAE • Greenish water.

• Green or black

spots on pool liner.

• Pool liner is

slippery and/or has

a bad odor.

• Chlorine and pH levels

need adjustment.

• Super chlorinate with shock

treatment. Correct pH to your

pool store's recommended

level.

• Vacuum pool bottom.

• Maintain proper chlorine

level.

COLORED

WATER

• Water turns blue,

brown, or black

when first treated

with chlorine.

• Copper, iron or maganese

in water being oxidized by

the added chlorine.

This is common.

• Adjust pH level to the

• Run filter until water is clear.

• Clean cartridge frequently.

FLOATING

MATTER IN

WATER

• Water is cloudy or

milky.

CHRONIC LOW

WATER LEVEL

• Level is lower than

on previous day.

SEDIMENT

ON POOL

BOTTOM

SURFACE

DEBRIS

• Dirt or sand on

pool floor.

• Leaves, insects etc.

• "Hard water" caused

by a too high pH level.

• Chlorine content is low.

• Foreign matter in

water.

• Rip or hole in pool

liner or hoses.

• The drain valves are

loose.

• Heavy use, getting in

and out of pool.

• Correct the pH level. Check

with your pool dealer for

advice.

• Adjust the chlorine level.

• Clean or replace your filter.

• Repair with a patch kit.

• Finger tighten all caps.

• Use Intex pool vacuum to

clean bottom of pool.

• Pool too close to trees. • Use Intex pool skimmer.

IMPORTANT

If you continue to experience difficulty, please contact our Consumer Service

Department for assistance. See separate “Authorized Service Centers” sheet.

SAVE THESE INSTRUCTIONS

Page 15

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English

GENERAL AQUATIC SAFETY

Water recreation is both fun and therapeutic. However, it involves inherent risks of injury and death. To reduce your risk of injury, read and follow all product, package and package insert warnings and instructions. Remember, however, that product warnings, instructions and safety guidelines cover some common risks of water recreation, but do not cover all instances or risk and or danger.

For additional safeguards, also familiarize yourself with the following general guidelines as well as guidelines provided by nationally recognized Safety Organizations:

• Demand constant supervision.

• Learn to swim.

• Take the time to learn CPR and first aid.

• Instruct anyone who is watching your children about potential pool hazards and about the use of

protective devices such as locked doors, barriers, etc.

• Teach children what to do in case of an emergency.

• Always use common sense and good judgement when enjoying any water activity.

• Supervise, supervise, supervise.

For additional information on safety, please visit

• The Association of Pool and Spa Professionals: The Sensible Way to Enjoy Your

Aboveground/Onground Swimming Pool www.nspi.org

• American Academy of Pediatrics: Pool Safety for Children www.aap.org

• Red Cross www.redcross.org

• Safe Kids www.safekids.org

• Home Safety Council: Safety Guide www.homesafetycouncil.org

• Toy Industry Association: Toy Safety www.toy-tia.org

109

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and the receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

SAVE THESE INSTRUCTIONS

Page 16

(109) MODEL 633T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/13/2019

English 109

LIMITED WARRANTY

Your Krystal Clear™ Filter-Pump has been manufactured using the highest quality materials and workmanship. All Intex products have been inspected and found free of defects prior to leaving the factory. This Limited Warranty applies only to the Krystal

Clear™ Filter-Pump and accessories listed below.

The provisions of this Limited Warranty apply only to the original purchaser and is not transferable. This Limited Warranty is valid for the period noted below from the date of the initial retail purchase. Keep your original sales receipt with this manual, as proof of purchase will be required and must accompany warranty claims or the Limited Warranty is invalid.

Krystal Clear™ Filter-Pump Warranty – 2 Years

Hoses, Plunger Valves & Fittings Warranty – 180 days

If a manufacturing defect is found within the periods noted above, please contact the appropriate Intex Service Center listed in the separate “Authorized Service Centers” sheet. The Service Center will determine the validity of the claim. If the Service Center directs you to return the product, please carefully package the product and send with shipping and insurance prepaid to the Service Center. Upon receipt of the returned product, the Intex Service Center will inspect the item and determine the validity of the claim. If the provisions of this warranty cover the item, the item will be repaired or replaced at no charge.

Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth, no civil action may be instituted. The methods and procedures of this settlement board shall be subject to the rules and regulations set forth by the Federal Trade Commission (F.T.C.). IMPLIED WARRANTIES ARE LIMITED

TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INTEX, THEIR

AUTHORIZED AGENTS OR EMPLOYEES BE LIABLE TO THE BUYER OR ANY

OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES OR LIABILITIES.

Some states, or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This Limited Warranty does not apply if the products are subject to negligence, abnormal use or operation, accident, improper operation, improper voltage or current contrary to operating instructions, or to damage by circumstances beyond Intex’s control, including but not limited to, ordinary wear and tear and damage caused by exposure to fire, flood, freezing, rain, or other external environmental forces. This Limited Warranty applies only to those parts and components sold by Intex. The Limited Warranty does not cover unauthorized alterations, repairs or disassembly by anyone other than Intex Service

Center personnel.

DO NOT GO BACK TO THE PLACE OF PURCHASE FOR RETURN

OR REPLACEMENT. IF YOU ARE MISSING PARTS OR NEED

ASSISTANCE, PLEASE CALL US TOLL-FREE (FOR U.S. AND

CANADIAN RESIDENTS): 1-800-234-6839 OR VISIT OUR WEBSITE:

WWW.INTEXCORP.COM.

Proof of Purchase must accompany all returns or the warranty claim will be invalid.

SAVE THESE INSTRUCTIONS

Page 17

advertisement

Key Features

  • Timer function
  • Plunger valves
  • Strainer grid
  • Sediment release valve
  • Cartridge filter
  • Air release valves
  • GFCI protection
  • Easy setup

Related manuals

Frequently Answers and Questions

How often should I replace the filter cartridge?
It is recommended to replace the filter cartridge at least every 2 weeks.
How do I clean the filter pump?
Turn off the pump, disconnect the power cord, close the plunger valves, remove the housing cover, and remove the cartridge. Flush the housing with water and replace the cartridge. Then, reinstall the cover, open the valves, and reconnect the power cord.
What should I do if the filter pump is not working?
Check if the motor is plugged in, if the GFCI is tripped, and if the motor is overheated. If the pump still doesn't work, there might be an issue with the impeller or motor.
How do I store the filter pump for the off-season?
Disconnect the power cord, drain the pump, remove the hoses, disconnect the strainers, and remove the plunger valves. Coat the O-rings with petroleum jelly and store the pump in a dry place.