Cross Technologies 2017-03 Up+Downconverter, 70 MHz 950-1525 MHz Instruction manual
Advertisement
Advertisement
Instruction Manual
Model 2017-03
Up/Downconverter
March 2018, Rev. N
DOWNCONVERTER UPCONVERTER
MUTE ALARM
U F=1525 G=10.0
D F=1525 G=25.0
MENU
EXECUTE
MODEL 2017
UP/DOWNCONVERTER
C
ROSS
T
ECHNOLOGIES INC.
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
C ROSS T ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL [email protected]
INSTRUCTION MANUAL
MODEL 2017-03 Up/Downconverter
TABLE OF CONTENTS PAGE
Warranty
1.0 General
1.1 Equipment Description
1.2 Technical Characteristics
1.3 Monitor & Control Interface
2
3
3
4
5
1.4 Environmental Use Information 8
2.0 Installation
2.1 Mechanical
2.2 Rear I/O’s
2.3 Front Panel Controls, Indicators
2.4 Operation
2.5 Menu Settings
9
9
10
12
13
15
WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.
All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein.
2017-03 Manual, Rev. N
C ROSS T ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL [email protected]
Page 2 03/22/18
MODEL 2017-03 Up/Downconverter
1.0 General
1.1 Equipment Description
The 2017-03 L-band Up/Downconverter converts 70 MHz to 950-1525 MHz (Up) and 950-1525 MHz to 70
MHz (Down) in 1 MHz steps with low group delay and flat frequency response. Synthesized local oscillators
(LO) provide frequency selection. Multi-function push button switches select the RF frequency, gain, and other parameters. Front panel LEDs provide indication of DC power (green), PLL alarm for up and downconverters
(red), remote operation (yellow), and Upconverter mute (yellow). Gain can be manually controlled over a -10 to
+30 dB range for the Upconverter and over a 0 to +50 dB range for the Downconverter as adjusted by the front panel multi-function push-button switches. Remote operation allows selection of frequency and gain. Parameter selection and frequency and gain settings appear on the LCD display. Connectors are BNC female for IF and the optional external reference input and output, and Type F female for RF. LNB or SSPB +24 VDC and 10
MHz reference can be inserted on the RF lines as added options. A high stability (±0.01ppm) option is also available. It is powered by a 100-240 ± 10% VAC power supply and housed in a 1.75” X 19” X 16” 1RU chassis.
DOWNCONVERTER
AC
GND
UPCONVERTER
MUTE ALARM
U F=1525 G=10.0
D F=1525 G=25.0
MENU
EXECUTE
FRONT PANEL
RF IN
DOWNCONVERTER
LNB FUSE
F1
IF OUT 10 MHZ REF
OUTPUT
J2 DS8
VDC on RF
J1 J18
MONITOR
AND
CONTROL
5
9
4
8
3
7
2
6
1
J10
REAR PANEL
MODEL 2017
UP/DOWNCONVERTER
C
ROSS
T
ECHNOLOGIES INC.
10 MHZ
EXT REF
INPUT
IF IN
J3 J4 J20
UPCONVERTER
F2
RF OUT
SSPB FUSE
+24 VDC
DS7 J5
Figure 1.1 Model 2017-03 Front and Rear Panels
.95
to
1.525
GHz
IN
10MHz*
+24VDC*
.95 to 1.525
GHz
BP var atten
2.7
to
3.3
GHz
*OPTIONAL
1750 MHz
BP
CONTROLLER
1680 or
1820
MHz
70
MHz
IN var atten
1820
MHz
REF
2.7
to
3.3
GHz
1750 MHz
BP
120 MHz
LP
70
MHz
OUT
EXT
10MHz*
INT
10MHz
REF TO
UP
VCOS
U F=1525 G=+00.0
D F=1450 G=+25.0
REF
..95 to 1.525
GHz var atten
10MHz*
+24VDC*
.95 to
1.525
GHz
OUT
Figure 1.2 Model 2017-03 Up/Downconverter Block Diagram
2017-03 Manual, Rev. N Page 3 03/22/18
1.2 Technical Characteristics
TABLE 1.0 2017-03 Up/Downconverter Specifications*
--------UPCONVERTER--------
Input Characteristics (IF)
Impedance/Return Loss
Frequency
Input Level
Output Characteristics (RF)
Impedance/Return Loss
Frequency
Output level
Output 1 dB compression
Channel Characteristics
Gain range (adjustable)
Frequency Sense
75
70 ± 18 MHZ
-40 to -10 dBm
75
Ω
Ω
/18 dB
/12 dB
950 to 1525 MHz
-20 to 0 dBm
+5 dBm
-10 dB to +30 dB
Non-inverting
--------DOWNCONVERTER--------
Input Characteristics (RF)
Impedance/Return Loss
Frequency
Noise Figure (max.)
Input Level
Input 1 dB compression
Output Characteristics (IF)
75 Ω /12 dB
950 to 1525 MHz
15 dB @ max. gain
-70 to -20 dBm
-15 dBm @ 0 dB gain
Impedance/Return Loss
Frequency
Output level/max. linear
Output 1 dB compression
Channel Characteristics
75 Ω /18 dB
70 ± 18 MHz
-20 dBm/-10 dBm
-5 dBm
Gain range (adjustable)
Image Rejection
Freq Sense (selectable)
0 dB to +50 dB
> 50 dB, min.
Inverting/Non-inverting
--------UP AND DOWNCONVERTER--------
Channel Characteristics
Frequency Response
Spurious Response
±1.5 dB, 950 - 1525 MHz; ± 0.5 dB, 36 MHz BW
<-50 dBC in band
0.01 ns/MHz2 parabolic; 0.03 ns/MHz linear; 1 ns ripple Group Delay (max.)
Synthesizer Characteristics
Frequency Accuracy
Frequency Step
Phase Noise @ Freq
± 1.0 ppm max. over temp (±0.01 ppm, option -H) internal reference
1 MHz (125 kHz, option X)
100 Hz 1kHz 10kHz 100kHz 1MHz
dBC/Hz -75 -75 -85 -100 -120
10 MHz Level (In or Out)
Controls, Indicators
Frequency Selection
Gain Selection
Power
Down/Up Alarm
Up Mute
Remote
3 dBm ± 3 dB, 75 ohms (option -E)
Direct readout LCD; manual or remote selection
Direct readout LCD; manual or remote selection
Green LED
Red LED
Yellow LED
Yellow LED; RS232C, 9600 baud
(RS485, option -Q, Ethernet M&C Remote Interface, option-W8)
Other
RF Connectors
IF Connectors
10 MHz Connectors
Alarm/Remote Connector
Size
Power
Options
-E
-H
-L
-V
-T
-X
-Z
Comm. Interface/Standard RS232
-Q
-W8
-W18
-W28
Connectors/Impedance
Type F (female) (see Table 2.2 for connector options)
BNC (female) (see Table 2.2 for connector options)
BNC (female) (option -E)
DB9 (female) - NO or NC contact closure on alarm
19 inch, 1RU standard chassis 1.75”H X 16.0”D
100-240 ±10% VAC, 47-63 Hz, 45 watts max.
External 10 MHz reference input & output w/ RF insertion
High Stability (±0.01ppm) internal reference
LNB Voltage, +24VDC, 0.5 amps
SSPB Voltage, +24VDC, 2.5 amps
Temperature Sensor
125 kHz frequency step
Upconverter Attenuator, 0.1 dB
RS485 Remote Interface
Ethernet; with Web Browser
Ethernet; with Web Browser & SNMP
Ethernet; with TCP/IP, Telnet ®
See Table 2.2
*+10˚C to +40˚C; Specifications subject to change without notice.
2017-03 Manual, Rev. N Page 4 03/22/18
1.3 Monitor and Control Interface
A) Remote serial interface
Protocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit.
(RS-232C, RS-422, or RS-485 - option -Q)
M&C Cable Diagram - Cross Technologies Frequency Converters
Female DB-9
PC Com Port
Male DB-9
2015/16/17 M&C Port
7
8
5
6
9
3
4
1
2
RX
TX
DTR
SG
DSR
RTS
CTS
RX
TX
SG
7
8
5
6
9
3
4
1
2
Connector: Rear panel, DB-9 male
6
7
4
5
Pin
1
2
3
8
9
Function
Rx-
Rx+ (RS-232C)
Tx+ (RS-232C)
Tx-
GND
Alarm Relay: Common
Alarm Relay: Normally Open
Not Used
Alarm Relay: Normally Closed
2017-03 Manual, Rev. N Page 5 03/22/18
B) Status Requests
Table 1.1 lists the status requests for the 2017-03 and briefly describes them.
* PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when RS-485, (OPTION-Q), is selected.
Command
Command Status
External 10 MHz (option -E)
SSPB Current (option -V)
Unit Temperature (option -T)
Syntax*
{aaS1}
{aaS2}
{aaS4}
{aaST}
Description
Returns {aaS1bbbbccccdddeeffLMNOP} where:
• bbbb = Tx frequency
4 characters - standard (7 characters - Option-X)
• cccc = Rx frequency
4 characters - standard (7 characters - Option-X)
• ddd = Tx gain (-10 to 30) (4 characters - Option-Z)
• ee = Rx gain (00 to 50)
• ff = Tx input level (10 to 40 => -10 to -40 dBm)
• L = 0 - non-inverted Receiver; L = 1 - inverted
• M = 0 - Receiver synth alarm
• N = 0 - Transmitter synth alarm
• O = 0 - Summary alarm
• P = 0 - Transmit signal disabled (muted)
Returns {aaS2bcd} } where:
• b = 10 MHz Selected (0=Internal; 1=External]
• c = Upconverter 10 MHz insertion RF [J5]
(0 = not inserted; 1=inserted)
• d = Downconverter 10 MHz insertion RF [J2]
(0 = not inserted; 1=inserted)
Returns {aaS4bbb} where:
• bbb = SSPB current, range 000 to 250 (0 to 2500 ma)
Returns {aaSTbbb} where:
• bbb = Unit Temperature in degrees C
2017-03 Manual, Rev. N Page 6 03/22/18
C) Commands
Table 1.2 lists the commands for the 2017-03 and briefly describes them. After a command is sent the 2017-03 sends a return “>” indicating the command has been received and executed.
General Command Format - The general command format is {aaCND...}, where:
{ = start byte aa = address (RS-485 only option -Q)
C = 1 character, either C (command) or S (status)
N = 1 character command or status request
D = 1 character or more of data (depends on command)
} = stop byte
* PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when RS-485, (OPTION-Q), is selected.
Table 1.2 2017-03 Commands
Command
Set Transmitter Frequency
Set Transmitter Input Level
Set Receiver Frequency
Set Transmit Gain
Set Receiver Gain
Enable Tx
External 10MHz (option -E)
Insert 10MHz on UP RF (option -E)
Insert 10MHz on DOWN RF (option -E)
Downconverter Spectrum
Enable Remote
Disable Remote
Syntax* Description
{aaC1xxxx} where:
• xxxx = 4 characters standard (7 characters -Option-X)
{aaCIxx}
• Range: 0950 to 1525 MHz where:
• xx = 2 characters
• Range: 10 to 40 (-10 to -40 dBm)
{aaC2xxxx} where:
• xxxx = 4 characters standard (7 characters -Option-X)
• Range: 0950 to 1525 MHz
{aaC3xxxx} where:
• xxxx = 2 or 3 characters
{aaC4xx}
{aaCAx}
{aaCEx}
{aaC5x}
• Range: -10 to 30 (-10 dB to 30 dB, in 1 dB steps) where:
• xx = 2 characters
• Range: 00 to 50 (00 dB to 50 dB, in 1 dB steps) where x =:
• 0 to disable Tx signal
• 1 to enable Tx signal where x =:
• 0 to disable External 10MHz ref signal
• 1 to enable External 10MHz ref signal where x =:
Upconverter
{aaC6x}
{aaC7x}
#
{aaCR0}*
Upconverter where x =:
Downconverter
Downconverter where x =:
• 0 for non-inverted
• 1 for inverted
Just # sign
{CR and zero}
2017-03 Manual, Rev. N Page 7 03/22/18
1.4 Environmental Use Information
A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack.
B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution.
C. Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature.
Therefore, consideration should be given to Tmra.
D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between units may be required.
E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring.
Appropriate consideration of equipment name plate rating should be used when addressing this concern.
F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connection to the
Branch (use of power strips).
G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed.
If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems.
2017-03 Manual, Rev. N Page 8 03/22/18
2.0 Installation
2.1 Mechanical
The 2017-03 consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switching, ± 12, +5, +24 VDC power supply provides power for the assemblies. The 2017-03 can be secured to a rack using the 4 holes on the front panel. Figure 2.0 shows how the 2017-03 is assembled.
POWER
SUPPLY
Figure 2.0 Model 2017-03 Mechanical Assembly
2017-03 Manual, Rev. N Page 9 03/22/18
2.2 Rear Panel Input/Output Signals and Control -
Figure 2.2 shows the input and output connectors on the rear panel.
AC1 - POWER IN
AC input for switching power supply.
100-240 ±10% VAC,
47-63 Hz.
AC
J2 - RF IN
950-1525 MHz input, -70 to -
20 dBm, see Table 2.2.
F1 - LNB FUSE (option -L)
0.5A, Fast Blo, 1/4” Fuse; installing fuse places +24 VDC, 0.4 Amps, max on the RF IN (J2 center pin).
J1 - IF OUT
70 MHz output, -20 to -10 dBm, see Table 2.2.
J10 - MONITOR AND CONTROL
DB9 female connector. see Table 2.1.
GND
RF IN
DOWNCONVERTER
LNB FUSE
F1
DS8
VDC on RF
IF OUT 10 MHZ REF
OUTPUT
MONITOR
AND
CONTROL
5 4 3
9 8
2
7 6
1
J10
J2 J1 J18
DS8 - LNB ALARM LED (option -L)
Lights yellow when +24 VDC LNB voltage is present on RF IN, J2, center pin.
J3 - 10 MHz EXT REF INPUT (Option -E)
10 MHz external reference input, 0 ± 3 dBm,
75 ohms, BNC female connector.
J20 - Ethernet Connection
RJ45 Ethernet Connector
UPCONVERTER
10 MHZ
EXT REF
INPUT
IF IN
J3 J4 J20
J18 - 10 MHz REF OUTPUT (option -E)
10 MHz reference output.
75 Ω BNC female connector.
F2 - SSPB FUSE (option -V)
2.5A, Fast Blo, 1/4” Fuse; installing fuse places +24 VDC,
2.5 amp, max on the RF OUT (J5 center pin).
F2
SSPB FUSE
+24 VDC
DS7
RF OUT
J5
J4 - IF IN
70 MHz input, -10 to -40 dBm in, see Table 2.2.
DS7 - SSPB ALARM LED (option -V)
Lights yellow when +24 VDC SSPB voltage is present on RF OUT, J5, center pin.
J5 - RF OUT
950-1525 MHz output, 0 to -20 dBm out, see Table 2.2.
Figure 2.1 Model 2017-03 Rear Panel I/O’s
2017-03 Manual, Rev. N Page 10 03/22/18
Tables 2.1 & 2.2 shows the input and output connectors on the rear panel.
6
7
8
9
3
4
5
Pin
1
2
Function
Rx-
Rx+ (RS-232C)
Tx+ (RS-232C)
Tx-
GND
Alarm Relay: Common
Alarm Relay: Normally Open
Not Used
Alarm Relay: Normally Closed
*Remote Serial Interface
Interface: DB-9 Male -- Protocol: RS-232C (RS-232C/422/485 option -Q),
9600 baud rate, no parity, 8 data bits, 1 start bit, 1 stop bit.
Option
STD
-B
-C
-D
-J
-N
-M
-S
IF
BNC, 75 Ω
BNC, 75 Ω
BNC, 75 Ω
BNC, 50 Ω
BNC, 50 Ω
BNC, 75 Ω
BNC, 50 Ω
BNC, 50 Ω
RF
Type F, 75 Ω
BNC, 75 Ω
BNC, 50 Ω
BNC, 50 Ω
Type F, 75 Ω
Type N, 50 Ω
Type N, 50 Ω
SMA, 50 Ω
2017-03 Manual, Rev. N Page 11 03/22/18
2.3 Front Panel Controls and Indicators -
The following are the front panel controls and indicators.
DS3 - DOWN ALARM LED
Red LED indicates
Downconverter alarm.
DS1 - REMOTE LED
Yellow LED indicates remote operation.
LCD DISPLAY
Display shows Up and
Downconverter frequency in MHz and Gain in dB
S1 - MENU/EXECUTE BUTTON
Press this to get into Program mode and to execute any changes.
DOWNCONVERTER UPCONVERTER
U F=1525 G=+10.0
D F=1450 G=+25.0
MENU
EXECUTE
MUTE ALARM
DS6 - POWER LED
Green LED indicates presence of DC power.
DS5 - UP MUTE LED
Yellow LED indicates
Upconverter mute.
DS2 - UP ALARM LED
Red LED indicates
Upconverter alarm.
S2 - VERT. TOGGLE
Vertical toggle switch that controls values in the Menu items when in program mode. Does not function in the normal display mode
Figure 2.2 Model 2017-03 Front Panel Controls and Indicators
2017-03 Manual, Rev. N Page 12 03/22/18
2.4 Installation / Operation
2.4.1 Installing and Operating the 2017-03, Upconverter Section
1.) Connect a -40 dBm to -10 dBm signal to IF In, J4 (Figure 2.1).
2.) Connect the RF OUT, J5, to the external equipment.
3.) Connect 100-240 ±10% VAC, 47 - 63 Hz to AC on the back panel.
4.) Set the desired output frequency (See Section 2.5 Menu Settings).
5.) Set the input level (See Section 2.5 Menu Settings).
6.) Set the gain (See Section 2.5 Menu Settings).
7.) (option -V) To power the SSPB (+24 VDC, 2.5 amps max.) from the 2017-03 install a
2.5 amp 1/4” fuse in F2.
CAUTION!!! INSTALLING A FUSE IN F2 PUTS +24 VDC, 2.5 AMP POWER ON THE CENTER PIN
AND MAY DAMAGE EQUIPMENT IF IMPROPERLY CONNECTED TO EQUIPMENT THAT
CANNOT HANDLE THIS VOLTAGE OR HAS A DC PATH TO GROUND.
8.) Be sure DS6 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.2).
2.4.2
Installing and Operating the 2017-03, Downconverter Section
1.) Connect a -70 dBm to -20 dBm signal to RF In, J2 (Figure 2.1).
2.) Connect the IF OUT, J1, to the external equipment.
3.) Connect 100-240 ±10% VAC, 47 - 63 Hz to AC on the back panel.
4.) Set the desired input frequency (See Section 2.5 Menu Settings).
5.) Set the gain to get an output level in the 0 to -20 dBm range (See Section 2.5 Menu Settings).
6.) (option -L) To power the LNB (+24 VDC, 0.5 amps, max.) from the 2017-03 install a 0.5 amp 1/4” fuse in F1.
CAUTION!!! INSTALLING A FUSE IN F1 PUTS +24 VDC, 0.5 AMP POWER ON THE CENTER PIN
AND MAY DAMAGE EQUIPMENT IF IMPROPERLY CONNECTED TO EQUIPMENT THAT
CANNOT HANDLE THIS VOLTAGE OR HAS A DC PATH TO GROUND.
7.) Be sure DS6 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.2).
8.) AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the drawer below the AC input as shown in Figure 2.3. There is a spare fuse in the near slot.
If a fuse continues to open, the power supply is most likely defective.
2017-03 Manual, Rev. N Page 13 03/22/18
FUSE DRAWER
SPARE FUSE
AC Fuse - 2 amp slow blow (Type T),
5 mm X 20 mm
INPUT
~
100-240± 10%VAC
47-63 Hz
2A MAX
FUSE
TYPE T 2A GDC
250 VOLT
FOR 100 - 240 V~
Figure 2.3 Fuse Location and Spare Fuse
2017-03 Manual, Rev. N Page 14 03/22/18
2.5 Menu Settings
2.5.1 Functions - This section describes operation of the front panel controls. There are three operator switches, the LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these components. The functions are (See Figure 2.2):
Power Up
Normal Display
Menu 1
Menu 2
Menu 3
Menu 4
Menu 5
Up Frequency in MHz
Up Input Lvl (Set from -40 to -10)
Up Gain (-10 to +30)
Down Frequency in MHz
Down Gain (set 0 to +50 for -20 to 0 dBm out range)
Menu 7
Menu 8
Set Unit to Remote Operation
Set Downconverter Spectrum Sense
Menu 9 Select External 10 MHz Ref (option -E)
Menu 10 Upconverter Reference Out (option -E)
Menu 11 Downconverter Reference Out (option -E)
Menu 12 Set RS-485 mode (option -Q)
Menu 13 Set RS-485 address (option -Q)
Menu 14 View PCB Temperature (option -T)
Menu 15 View LNB and/or SSPB Current (options -L and/or -V)
Save Menu At the end or when “R” is selected from any of the above menus
Alarm indications appear on the LEDs (see figure 2.2).
All program changes must start with the operation of the Menu/Execute switch and must also end with the operation of the Menu/Execute switch verified by the “Save Settings?” Menu. If this sequence is not followed, none of the changes will take effect. If programming is initiated and no operator action takes place for approximately 12 seconds (before the final press of the Menu/Execute switch) the display will revert to its previous status and you will need to start over.
2017-03 Manual, Rev. N Page 15 03/22/18
2.5.2 Power-On Settings
NOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED.
WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO IT'S PREVIOUS SETTINGS.
When power is first applied, the LCD display goes through three steps.
1. The LCD goes black to show all segments are functioning.
2. The software version will be displayed.
R E V 1 . 0 0
3. The present frequency and gain of the up and Downconverter is shown.
U F=1525 G=+10.0
D F=1450 G=+25.0
The unit is now operational and ready for any changes the operator may desire.
2.5.3 Control Switches
1. Menu/Execute - Any change to the programming of the unit must be initiated by pressing the
Menu/Execute switch and completed by pressing the Menu/Execute switch.
2. Horizontal Switch - This switch is mounted so its movement is horizontal and moves the cursor left or right.
3. Vertical Switch - This switch is mounted so its movement is vertical and has two functions: a. During frequency , gain, input level changes, the vertical movement will raise or lower the number in the direction of the arrows.
b. For other functions such Mute on/off, the vertical switch will alternately turn the function on or off regardless of the direction operated.
2.5.4 Frequency Changes
At any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, do not press the Menu/Execute switch; simply do nothing for approximately 12 seconds, and the system will return to the normal operating mode or scroll to “R” and push the menu/Execute switch and select “NO” in the “SAVE SETTINGS?” window.
2017-03 Manual, Rev. N Page 16 03/22/18
To change the FREQUENCY:
Operate the Menu/Execute switch until you get to the menu item you want to change (see Figure 2.4 for the sequence of menu options). The following display is for changing the Upconverter frequency:
UP F = 1350 R
Pressing the Up/Down switch down will toggle the display to:
UP F = 1450 R
By using the horizontal rocker switch the cursor can be moved left or right.
UP F = 1450 R
NOTE: CHANGES DO NOT TAKE PLACE ON FREQUENCY UNTIL YOU GO TO THE SAVE
MENU AND INDICATE YOU WANT TO SAVE THE CHANGES.
When the display indicates the value desired you can push the Menu/Execute switch to the next item:
UP INLVL = -20 R
NOTE: CHANGES TAKE PLACE ON LEVEL AND GAIN IMMEDIATELY BUT DO NOT GET
SAVED UNTIL YOU GO TO THE SAVE MENU AND INDICATE YOU WANT TO SAVE THE
CHANGES.
OR you can scroll to “R”, push the Menu/Execute switch to get to:
SAVE SETTINGS?
Y N
Selecting Y will save the new settings. Selecting N will revert to the previous settings.
Pushing the Menu/Execute switch then takes you to the :
U F=1450 G=+10.0
D F=1250 G=+20.0
Figure 2.4 shows all the menu items and how to make changes.
2.5.5 Gain Changes
When you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes you have made, scroll to “R” and push the menu/Execute switch and select “NO” in the
“SAVE SETTINGS?” window or do not press the Menu/Execute switch; simply do nothing for approximately 12 seconds, and the system will return to the normal operating mode.
2017-03 Manual, Rev. N Page 17 03/22/18
2.5.5.1 Upconverter Gain
To set the Upconverter gain, first push the Menu/Execute switch to get to the gain setting:
Operate the Menu/Execute switch until you get to the menu item you want to change see Figure 2.4 for the sequence of menu options.
The following display is for changing the Upconverter input level. This is an important setting to optimize spurious and should be made as accurately as possible:
UP INLVL = -20 R
Pressing the Up/Down switch to change the level in 1 dB steps and then push the Menu/Execute switch to get to the Gain setting:
UP G = +20.0
R
By using the horizontal rocker switch the cursor can be moved left or right .
Pressing the Up/Down switch down will toggle the display digit selected until you have the desired gain.
NOTE: THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS. HOWEVER, THE
VALUE WILL NOT BE STORED UNTIL YOU INDICATE YES IN THE SAVE SETTINGS
WINDOW. DO NOT SET A GAIN THAT WOULD EXCEED A 0 dBm OUTPUT LEVEL.
When the display indicates the value desired you can push the Menu/Execute switch to the next item
OR you can scroll to “R”, push the Menu/Execute switch to get to:
SAVE SETTINGS?
Y N
Selecting Y will save the new settings. Selecting N will revert to the previous settings.
Pushing the Menu/Execute switch then takes you to the :
U F=1450 G=+20.0
D F=1350 G=+20.0
Figure 2.4 shows all the menu items and how to make changes.
2017-03 Manual, Rev. N Page 18 03/22/18
2.5.5.2 Downconverter Gain
To set the Downconverter gain, first push the Menu/Execute switch to get to the gain setting:
Operate the Menu/Execute switch until you get to the menu item you want to change see Figure 2.4 for the sequence of menu options.
The following display is for changing the Downconverter gain. This is an important setting to optimize spurious and should be made as accurately as possible to provide an output in the -20 to 0 dBm level range:
DN G = +30.0
R
Pressing the Up/Down switch to change the level in 1 or 10 dB steps. By using the horizontal rocker switch the cursor can be moved left or right. Pressing the Up/Down switch down will toggle the display digit selected until you have the desired gain.
NOTE: THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS. HOWEVER, THE
VALUE WILL NOT BE STORED UNTIL YOU INDICATE YES IN THE SAVE SETTINGS
WINDOW.
When the display indicates the value desired you can push the Menu/Execute switch to the next item
OR you can scroll to “R”, push the Menu/Execute switch to get to:
SAVE SETTINGS?
Y N
Selecting Y will save the new settings. Selecting N will revert to the previous settings.
Pushing the Menu/Execute switch then takes you to the :
U F=1450 G=+20.0
D F=1350 G=+30.0
Figure 2.4 shows all the menu items and how to make changes.
2.5.5.3 Alarm Indications
An alarm condition for will occur if any local oscillator phase lock loop (PLL) comes out of lock.
2017-03 Manual, Rev. N Page 19 03/22/18
ON POWER UP
REV 1.00
Power Up
Normal Display
Menu 1 Up Frequency
Menu 2 Up Input Level (Set from
-40 to -10)
Menu 3 Up Gain (-10 to +30)
Menu 4 Down Frequency
Menu 5 Down Gain (set 0 to +50 for -20 to 0 dBm out level)
Menu 6 Up Mute
Menu 7 Set Unit to Remote
Operation
Menu 8 Set Downconverter
Spectrum Sense
Menu 9 Select External 10 MHz
Reference (option -E)
Menu 10 Select Upconverter
Reference Out (option -E)
Menu 11 Select Downconverter
Reference Out (option -E)
Menu 12 Set Remote Mode
(option -Q)
Menu 13 Set RS-485 Address
(option -Q)
Menu 14 View PCB Temperature
(option -T)
Menu 15 View LNB current and
SSPB current (options -L, -V)
Save Settings? At the end or when “R” is selected from any of the above menus
NORMAL DISPLAY
U F = 1450 G = +10.0
D F = 1350 G = +25.0
PUSHING MENU/EXECUTE SEQUENCE
UP F = 1450 R
UP INLVL = -20
UP G = +10.0
DN F = 1350
DN G = +25.0
UP MUTE OFF
REMOTE OFF
DNSPECTRUM NON
EXT REF OFF
UP REF OUT OFF
DN REF OUT OFF
RS 485 OFF
ADDRESS = 00
R
R
R
R
R
R
R
R
R
R
R
R
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
SCROLL <>
SCROLL
TEMP = 35 DEG R
SCROLL <>
SSB DC = 1.86 A
SCROLL <>
SAVE SETTINGS? Y N
SCROLL <>
Figure 2.4 Menu Display and Sequence
2017-03 Manual, Rev. N Page 20
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
PUSH BUTTON
03/22/18
C ROSS T ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL [email protected]
Printed in USA
2017-03 Manual, Rev. N Page 21 03/22/18