AN-510-AP-I-AC
AN-810-AP-I-AC
Araknis Networks Wireless Access Point
Quick Start Guide
2
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This device is designed for indoor use only.
IMPORTANT NOTE:
FCC Radiation Exposure Statement :
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
In the North American market, only channels 1–11 can be operated. Other channels cannot be selected.
Support: 866.838.5052
Araknis Networks Wireless Access Point
Quick Start Guide
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Caution:
(i) The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
(ii) For product available in the USA/Canada market, only channel 1–11 can be operated. Selection of other channels is not possible.
Avertissement:
(i) Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux;
(ii) Pour les produits disponibles aux États-Unis / Canada du marché, seul le canal 1 à 11 peuvent être exploités.
Sélection d’autres canaux n’est pas possible.
© 2020 Araknis Networks® 3
Araknis Networks Wireless Access Point
Quick Start Guide
4
Radiation Exposure Statement:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Déclaration d’exposition aux radiations:
Cet équipement est conforme aux limites d’exposition aux rayonnements ISED établies pour un environnement on contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
This product meets the applicable Innovation, Science and Economic Development Canada technical specifications.
Ce produit repond aux specifications techniques applicables a l'innovation, Science et Développement economique
Canada
This is a product with CE certification. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
These products are intended to be powered by either PoE/PoE+ or a 12V/2A power supply.
These products use PoE/PoE+ IN(48V/0.53A) for both the AN-510-AP-I-AC and AN-810-AP-I-AC.
Support: 866.838.5052
Araknis Networks Wireless Access Point
Quick Start Guide
This equipment complies with EU radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.
All operational modes:
2.4GHz: 802.11b, 802.11g, 802.11n (HT20), 802.11n (HT40), 802.11ac (VHT20), 802.11ac (VHT40)
5GHz: 802.11a, 802.11n (HT20), 802.11n (HT40), 802.11ac (VHT20), 802.11ac (VHT40), 802.11ac (VHT80)
The frequency and the maximum transmitted power in EU are listed below:
AN-510-AP-I-AC
2412-2472MHz: 14.7 dBm
5180-5240MHz: 17.4 dBm
AN-810-AP-I-AC
2412-2472MHz: 17dBm
5180-5240MHz: 18dBm
The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range..
AT
EE
IT
PT
BE
FI
LV
RO
BG
FR
LT
SK
HR
DE
LU
SI
CY
EL
MT
ES
CZ
HU
NL
SE
DK
IE
PL
UK
© 2020 Araknis Networks® 5
6
Araknis Networks Wireless Access Point
Quick Start Guide
Thank you for choosing an Araknis™ WAVE 2 AC Wireless Access Point (WAP). With newly designed circular housing, an ingeniously easy new mounting system, convenient PoE power, and the latest WAVE 2 AC wireless technologies, these products are ideal as staples in both residential and commercial applications.
• Sleek Circular Design
• Unobtrusive Recessed Lighting
• 1 x Gigabit LAN Port (w/802.3at PoE-IN)
• 1 x Gigabit LAN Port (data only)
• 1 x USB 2.0 (power only)
• Multi-User MIMO
• AN-510-AP-I-AC: 2x2 Dual-Band Wave 2-AC 1300Mbps
• AN-810-AP-I-AC: 4x4 Dual-Band Wave 2-AC 2600Mbps
• OvrC Enabled
AN-510-AP-I-AC
AN-810-AP-I-AC
Support: 866.838.5052
Araknis Networks Wireless Access Point
Quick Start Guide
Wireless Access Point
(WAP)*
Mounting Bracket Tile Ceiling Backing Plate Quick Start Guide
Male-to-Female
Category Jumper Cable
Tile Ceiling
Mounting Hardware
Drywall
Mounting Hardware
*This manual uses the 810 WAP for illustrative purposes throughout.
© 2020 Araknis Networks®
Wood Surface
Mounting Hardware
(510 has 2 screws)
7
Araknis Networks Wireless Access Point
Quick Start Guide
A
B
8
NOTE: Use the ceiling back plate on top of acoustic ceiling tiles to prevent the mounting nuts from pulling through.
Support: 866.838.5052
Araknis Networks Wireless Access Point
Quick Start Guide
Ceiling Tiles
WAP
Center
Line*
Position 1
Ceiling Mount
Center
Line*
Position 2
* Center line of the bracket is not necessarily the center line of the WAP when installed. Please use the guide above to understand the center line of the WAP when installing the bracket.
© 2020 Araknis Networks® 9
10
Araknis Networks Wireless Access Point
Quick Start Guide
You can mount your access point to the electrical box in one of two positions, shown below. These options are provided to provide cable bend relief for cables of different lengths and thicknesses. Illustrations do not reflect pre-install steps—please run the wire or jumper prior to connecting the access point.
Double Gang
Box (not included)
Single Gang
Box (not included)
Cat 6A
Cat 5e
NOTE: Jumper is needed when using Cat 6A in Position B.
Jumper
Support: 866.838.5052
Araknis Networks Wireless Access Point
Quick Start Guide
Internet
LAN WAN
Router
Internet
LAN WAN
Router
Internet
© 2020 Araknis Networks®
LAN WAN
Router
PoE Switch
AN-310-SW-F-8-POE
WAP
Switch
AN-310-SW-F-8-POE
OUT) POWER + D
AN-ACC-INJ-30W
DC 48V Input Power DATA (IN)
PoE Injector
(not included)
WAP
Switch
AN-310-SW-F-8-POE
WAP DC Power Supply
(not included)
11
Araknis Networks Wireless Access Point
Quick Start Guide
LED* LED*
12
*NOTE: The LED is located on the side of the device.
• Blinking: WAP is not working correctly. Contact Araknis technical support.
• Solid White: WAP is booting up (810 only).
• Solid Blue: WAP is operating correctly.
Support: 866.838.5052
A Log in using the default credentials:
Username
Password araknis araknis
Araknis Networks Wireless Access Point
Quick Start Guide
NOTE: If you can’t connect to the WAP using this method, or need to configure the device before connecting it to the network, try these options for accessing your device:
• DHCP IP address – Page 15
• Default IP Address – Page 16
• OvrC – Page 19
© 2020 Araknis Networks® 13
Araknis Networks Wireless Access Point
Quick Start Guide
After making changes to settings on a menu page, click the “Save” button on the menu to hold the new settings in the
Apply Changes field.
14
After all desired changes have been made, click “Apply Changes” to review the new settings if any. Click "Apply" to make the changes or "Revert" to cancel the changes.
NOTE: Settings will take affect after the progress bar completes 100%.
Support: 866.838.5052
Araknis Networks Wireless Access Point
Quick Start Guide
The WAP is configured to DHCP by default so that the DHCP server can assign an IP address when the WAP is connected to the network (the DHCP server is usually the router). This address can be used for accessing the web interface.
Use one of these methods to find the IP address of the WAP:
• Check the client table on your router
• Use a network scanner (e.g. Fing) to sniff the network. The
Araknis WAP manufacturer field will display “Snap AV”
See the highlighted field in the "Fing" screenshot to the right for an example of an Araknis device being identified.
© 2020 Araknis Networks® 15
16
Araknis Networks Wireless Access Point
Quick Start Guide
If the WAP is not issued an IP address on the network, or needs to be accessed while not connected to a network, you can configure your computer's network connection to allow access using the default IP address,
“ 192.168.20.253
”.
Windows 7 screenshots shown for reference.
A Connect your PC to the WAP using a network patch cable.
B On your PC, open the Control
Panel and left-click “Network and Internet”.
C Left-click “Network and Sharing
Center”.
Computer WAP
Support: 866.838.5052
Araknis Networks Wireless Access Point
Quick Start Guide
Windows 7 screenshots shown for reference.
D In the left bar, left-click “Change adapter settings”.
E Right-click the icon for the wired network connection and left-click "Properties".
F Left-click to highlight “Internet
Protocol Version 4 (TCP/IPv4), then left-click “Properties”.
© 2020 Araknis Networks® 17
18
Araknis Networks Wireless Access Point
Quick Start Guide
Windows 7 screenshots shown for reference.
G In the “General” tab, left-click
"Use the following IP address:" and enter the IP address and subnet mask.
IP Address 192.168.20.2
Subnet Mask 255.255.255.0
H Left-click “OK” to close Internet
Protocol Version 4 (TCP/IPv4)
Properties, then left-click "OK" to close wireless network connection properties.
I Open a browser and navigate to http://192.168.20.253/ . Log in using the default credentials:
Username
Password araknis araknis
Support: 866.838.5052
Araknis Networks Wireless Access Point
Quick Start Guide
OvrC gives you remote device management, real-time notifications, and intuitive customer management, right from your computer or mobile device. Setup is plug-and-play, with no port forwarding or DDNS address required.
To add this device to your OvrC account:
A Connect the WAP to the Internet
B Log Into OvrC (www.ovrc.com)
C Add the Device (MAC address and Service Tag numbers needed for authentication)
© 2020 Araknis Networks®
Mobile
Apps
Web Browser
Access
Internet
OvrC Server
LAN WAN
3 4 5 6 8
1 Gbps
Link/Act
AN-110-SW-R-8
19
Araknis Networks Wireless Access Point
Quick Start Guide
20
Diameter
Weight
Antenna
Wireless Mode(s)
RJ-45 1000BASE-T
Ports
PoE Features
PoE Consumption
Antennas
Transmit Power
Receiver Sensitivity
Antenna MIMO
PHY Data Rate
Operating Frequencies
Channel Bonding
AN-510-AP-I-AC
7.25' X 1.53"
0.9 lbs
2x2
802.11 a/b/g/n/ac Wave 2
2
AN-810-AP-I-AC
9.25' X 1.91"
1.6 lbs
4x4
802.11 a/b/g/n/ac Wave 2
2
PoE 802.3af Compliant PSE
Power On: 2.79W
Full Load (Without USB 2.0): 6.8W
Full Load (with USB 2.0): 9.8W
PoE 802.3at Compliant PSE
Power On: 7.30W
Full Load (Without USB 2.0): 19.1W
Full Load (with USB 2.0): 21.9W
Embedded Antenna, Omni-Directional Embedded Antenna, Omni-Directional
Refer to the MCS Table Refer to the MCS Table
Refer to the MCS Table
2x2:2 MU-MIMO
Up to 400Mbps @ 2.4GHz
Up to 867Mbps @ 5GHz
2.4 GHz & 5 GHz
Yes (20 MHz, 40 MHz, and 80MHz)
Refer to the MCS Table
4x4:4 MU-MIMO
Up to 800Mbps @ 2.4GHz
Up to 1733Mbps @ 5GHz
2.4 GHz & 5 GHz
Yes (20 MHz, 40 MHz, and 80MHz)
Support: 866.838.5052
Araknis Networks Wireless Access Point
Quick Start Guide
Max TX Power
Wireless Features
VLAN Features
QoS Features
RJ45 Auto Sensing
RJ45 Auto Negotiation
AN-510-AP-I-AC
25dBm @ 2.4GHz
26dBm @ 5GHz
Auto Channel Selection
Operation Modes: Access Point,
Repeater
Multiple SSIDs: up to 8 per radio
Wireless Security: WPA2-PSK (AES +
TKIP), WPA-Enterprise
MAC Address Filtering
Hide SSID
Guest Network
Beamforming
Yes, 802.1Q
Yes, WME 802.11e
Yes
Yes
AN-810-AP-I-AC
22dBm @ 2.4GHz
24dBm @ 5GHz
Auto Channel Selection
Operation Modes: Access Point,
Repeater
Multiple SSIDs: up to 8 per radio
Wireless Security: WPA2-PSK (AES +
TKIP), WPA-Enterprise
MAC Address Filtering
Hide SSID
Guest Network
Beamforming
Yes, 802.1Q
Yes, WME 802.11e
Yes
Yes
© 2020 Araknis Networks® 21
22
Araknis Networks Wireless Access Point
Quick Start Guide
Management Features
Spanning Tree
Line Voltage
Operating Temperature
Storage Temperature
Operating Humidity
Certifications
AN-510-AP-I-AC
Web Management
Telnet
SNMP v1, v2c, v3
DHCP Client
System Log
Bonjour
UPnP
Remote Config File Download/Upload
OvrC Services
Wi-Fi Scheduler
Site Survey
LED Control
Auto Reboot
Yes, 802.1d
12V 2A DC
32-122°F
-4-140°F
90% or less
CE, FCC, IC, Wi-Fi
AN-810-AP-I-AC
Web Management
Telnet
SNMP v1, v2c, v3
DHCP Client
System Log
Bonjour
UPnP
Remote Config File Download/Upload
OvrC Services
Wi-Fi Scheduler
Site Survey
LED Control
Auto Reboot
Yes, 802.1d
12V 2A DC
32-122°F
-4-140°F
90% or less
CE, FCC, IC, Wi-Fi
Support: 866.838.5052
Management Features
Spanning Tree
Line Voltage
Operating Temperature
Storage Temperature
Operating Humidity
Certifications
AN-510-AP-I-AC
Web Management
Telnet
SNMP v1, v2c, v3
DHCP Client
System Log
Bonjour
UPnP
Remote Config File Download/Upload
OvrC Services
Wi-Fi Scheduler
Site Survey
LED Control
Auto Reboot
Yes, 802.1d
12V 2A DC
32-122°F
-4-140°F
90% or less
CE, FCC, IC, Wi-Fi
AN-810-AP-I-AC
Web Management
Telnet
SNMP v1, v2c, v3
DHCP Client
System Log
Bonjour
UPnP
Remote Config File Download/Upload
OvrC Services
Wi-Fi Scheduler
Site Survey
LED Control
Auto Reboot
Yes, 802.1d
12V 2A DC
32-122°F
-4-140°F
90% or less
CE, FCC, IC, Wi-Fi
Araknis Networks Wireless Access Point
Quick Start Guide
This product can expose you to chemicals including lead and lead compounds, which are known to the State of
California to cause cancer. For more information go to www.P65Warnings.ca.gov.
P (866) 838-5052 E [email protected]
Araknis Networks® products have a 2-Year Limited Warranty. This warranty includes parts and labor repairs on all components found to be defective in material or workmanship under normal conditions of use. This warranty shall not apply to products that have been abused, modified, or disassembled. Products to be repaired under this warranty must be returned to SnapAV or a designated service center with prior notification and an assigned return authorization (RA) number.
US local representative information:
Company: Araknis Networks
Address: 1800 Continental Blvd. Suite 300,
Charlotte, NC 28273
USA
Tel: 704.927.7620
Fax: 800.782.2410
© 2020 Araknis Networks®
200427-1716 23
Advertisement
How to access a WAP's web interface if the configuration address is unresponsive?
Check if the WAP has a DHCP IP address. If not, manually configure your computer's network connection to use IP address 192.168.20.253.
How to change a computer's default IP address?
In the Network and Sharing Center, change adapter settings, access wired network connection properties, and modify the IP address and subnet mask under Internet Protocol Version 4 (TCP/IPv4) to 192.168.20.2 and 255.255.255.0, respectively. Consult your operating system's documentation for specific instructions if not using Windows 7.
Login to continue