Danfoss AVQM-2 Data Sheet

Data sheet AVQM-2 Flow controller with integrated control valve Description / Application Combined with an electric actuator the AVQM-2 controller is a self-acting flow controller with integrated control valve. The pressure difference across the control valve is kept constantly at 0.2 bar. The controller is primarily used in district heating systems for circulation water with a max. temperature of 150 oC. AVQM-2 is used together with following actuators: - AMV(E) 23 / AMV(E) 33 with valve closing safety function, type tested acc. to DIN 32 730 - AMV(E) 20 / AMV(E) 30 Nominal diameter DN 40 and DN 50 Nominal pressure PN 25 Connection Flange Flow and return mounting Ordering Technical data Type DN AVQM-2 40 50 kvs m3/h 16 20 2) Because of the higher valve opening factor (Y), the noise level can be insignificantly higher, depending on the pressure ratio (XF) Reference: 0.75 x max. flow 003H1740 003H1741 Valve Nominal diameter kvs value Min. flow rate Nominal flow Max. flow rate 1) Nominal pressure Max. pressure difference z value acc. to VDMA 24 422 1) Code No. (DN) (m3/h) (PN) (bar) 2) Flow medium Medium temperature Type of connection Approx. valve weight Valve body material Seat material Cone material Cone seal material (oC) (kg) 40 16 0,8 10 12 50 20 1,0 12 15 25 16 0.6 Circulation water / Glycolic water up to 30 % 2 - 150 Flange, PN 25 DIN 2501 9 10 Ductile iron EN-GJS-400-18-LT (GGG 40.3) Stainless steel M. No. 1.4571 Brass, stainless steel M. No. 1.4404 EPDM Actuator Effective surface Nominal pressure Diff. pressure across control valve Max pressure difference between (+) chamber and (-) chamber Material (cm 2) (PN) (bar) (bar) 54 25 0.2 Body Stainless steel M. No. 1.4301 CuZn36Pb2As* EPDM Copper tube Ø 5x1 1.5 Diaphragm Impulse tubes Approx. weight (kg) 14 * Dezincing free brass DEBC-SC VD.DA.U1.02 Danfoss 01/03 1 Data sheet AVQM-2, flow controller with integrated control valve Application examples Flow mounting Return mounting Design and operation 1 2 1 2 3 4 5 6 Electric actuator Stroke adjustment Cone, control valve Seat Cone Pressure actuator 3 4 5 6 2 VD.DA.U1.02 Danfoss 01/03 This controller acts as flow limiter as well as control valve. The pressure actuator keeps a constant differential pressure across the control valve of 0.2 bar. The flow limitation is set by adjusting the stroke of the control valve's cone. DEBC-SC Data sheet AVQM-2, flow controller with integrated control valve Sizing diagram Pressure temperature diagram according to DIN 4747 and DIN 2401 pmax. (bar) 26 PN 25 25 24 23 22 21 20 0 100 110 120 130 140 150 t (°C) Maximum allowed operating pressure as a function of medium temperature. Installation The controller AVQM-2 can be installed in the flow and return of the system. The installation position can be freely chosen. If the controller is installed on the horizontal pipe, the electric actuator should be placed in an upward position. Adjustment The set-point for the flow limitation can be adjusted with the aid of adjustment characteristic curves (see the AVQM-2 instruction) or by a flow meter. If insulating against heat loss, ensure that only the valve is insulated. The electric actuator and the pressure actuator must not be insulated! Possible combinations (ordering on request) AMV(E)2(3). / AVPQM-2 - flow controller - differential pressure controller - control valve DEBC-SC VD.DA.U1.02 Danfoss 01/03 AMV(E)2(3). / AIT / AVQTM-2 - flow controller - temperature controller - control valve 3 Data sheet AVQM-2, flow controller with integrated control valve Dimensions H1 H2 155 DN L H1 (mm) H2 40 200 50 230 160 220 Flange: PN 25, DIN 2501 L2 AMV(E) 2(3). / AVQM-2 4 VD.DA.U1.02 Danfoss 01/03 DEBC-SC
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement