MAKING MODERN LIVING POSSIBLE

Danfoss Heat Pump

DHP-AL

Air/water heat pump that provides heating and hot water.

TWS

DANFOSS HEAT PUMPS

TWS

VDBMH602

Danfoss DHP-AL is an air/water heat pump that uses new innovative technology to operate at the highest possible annual efficiency. This means you can get

75% of your energy consumption for free – using renewable energy stored in the outdoor air. This provides a sustainable and environmentally friendly heating solution.

DHP-AL has a separate hot water tank, ideal if you have a low ceiling. The tank incorporates our patented TWS* technology, which produces hot water faster and at higher temperatures than with traditional technologies.

Defrosting is done automatically only on demand which further boosts efficiency.

DHP-AL operates at a low sound level and can be controlled and monitored via the Internet. The controller is advanced but very user friendly.

* Tap Water Stratificator, our patented technology developed to stratify hot

water in a tank to ensure that heat is used optimally.

910

1

2

300

DANFOSS DHP-AL

Connection

The brine lines can be connected on either the left or right-hand sides of the heat pump.

1 Brine in, 28 Cu

2 Brine out, 28 Cu

1

4 3

1175

2 1

1

2

1

2

455

690

1

40±10

2

455

690

4

6

3

5

7

40±10

2 2

2

1 1

6

5

7

Heat pump

1 Brine in, 28 Cu

2 Brine out, during normal

operation, 28 Cu

3 Brine out, during defrosting

to hwh pos 8, 28 Cu

4 Return pipe from water heater

pos 9, 28 Cu

5 Heating system supply line,

22 Cu: 6-10 kW, 28 Cu: 12 kW

6 Heating system return line,

22 Cu: 6-10 kW, 28 Cu: 12 kW

7 Lead-in power and sensor lead

15

17

11

Heat pump

9 8

455

690

1

4

40±10

3 455

690

1

9

40±10

4

8

2

14

16

13

12

10 11

7

15

17

6

455

690

455

690

2

6

14

16

13

12

10

7

5

15

11

14

16

13

12

15

17

10 11

3

9 8 9 8

8 Connection for brine

out when defrosting

from pos 3

455

690

9 Water heater, return

pipe to pos 4

10 Bleed valve, at stainless

steel water heater

11 Brine out during

defrosting, 28 Cu

12 Domestic hot

water, 22 Brass

13 Cold water, 22 Brass

14 Supply to water heater

coil

40±10

455

690

40±10

15 Brine, expansion outlet

when outdoor unit is

positioned at high level

16 Lead-in sensor lead

17 Temperature and

pressure valve

14

16

13

12

10

DHP-AL

Refrigerant

Compressor

Electrical data

3-N ~50Hz

Type

Amount

Type

Main supply

Rated power compressor

Rated power, circulation pumps/fan

Auxiliary heater, 5 steps

Start current

Circuit breaker

Electrical data

1-N ~50Hz

Performance

Main supply

Rated power compressor

Rated power, circulation pumps/fan

Auxiliary heater, 3 steps

Start current

Circuit breaker

COP 1

COP 2

Heating capacity 2

Power input 2

Lowest outdoor temperature allowed for compressor start

Max/min temperature Cooling circuit

Heating circuit

Water volume Water heater

Anti freeze media 10

Indoor unit

Water heater unit

Dimensions LxWxH

Weight

Sound power level 11

Dimensions LxWxH

Weight empty

Weight filled

Outdoor unit Dimensions LxWxH

Weight

Sound power level, low/high 12

Max. pipe length (Cu pipe Ø 28 mm between heat pump and outdoor unit)

The measurements are performed on a limited number of heat pumps which can cause variations in the results. Tolerances in the measuring methods can also cause variations.

kg

Volt kW

W kW

A

A

Volt kW

W kW

A

A kW kW

°C

°C

°C l mm kg dB(A) mm kg kg mm kg dB(A) m

6

R404A

0.95

Scroll

400

2.0

0.4

3/6/9/12/15

12

10 3 /16 4 /20 5 /20 6 /

25 7 /25 8 /30 9

230

3.3

0.4

1.5/3/4.5

11

25 3 /32 4 /40 5

3.88

3.26

5.90

1.8

–20

20/–25

55/20

180

690x596x1538

154

42.5

690x596x1538

172

352

630x1175x1245

94

53/63

60 (30+30) 60 (30+30)

1) At A7W35 Δ10 warm side (excluding circulation pumps and outdoor unit).

2) At A7W35 according to EN 14511 (including circulation pumps and outdoor unit).

3) Heat pump with 3 kW auxiliary heater (1-N 1.5 kW).

4) Heat pump with 6 kW auxiliary heater (1-N 3 kW).

5) Heat pump with 9 kW auxiliary heater (1-N 4.5 kW).

6) 12 kW auxiliary heater (compressor off).

8

R404A

1.45

Scroll

400

2.3

0.6

10

R404A

1.50

Scroll

400

3.6

0.6

3/6/9/12/15

100

16 3 /16 4 /20 5 /20 6 /

25 7 /25 8 /30 9

230

4.2

0.6

3/6/9/12/15

18

16 3 /16 4 /20 5 /20 6 /

25 7 /30 8 /35 9

230

5.4

0.6

1.5/3/4.5

21

25 3 /32 4 /40 5

4.06

3.45

7.96

2.3

–20

1.5/3/4.5

26

32 3 /40 4 /50 5

4.21

3.29

9.85

3.0

–20

20/–25

55/20

20/–25

55/20

180 180

Ethylene glycol + Water solution with a freezing point below –30°C

690x596x1538

154

47.7

690x596x1538

172

352

690x596x1538

154

45.5

690x596x1538

172

352

630x1175x1245

94

53/63

630x1175x1245

94

54/67

60 (30+30)

690x596x1538

162

48.1

690x596x1538

172

352

630x1175x1245

94

54/67

60 (30+30)

7) 15 kW auxiliary heater (compressor off).

8) Heat pump with 12 kW auxiliary heater.

9) Heat pump with 15 kW auxiliary heater.

10) Propylene glycol or ethanol may not be used.

11) Sound power level measured according to EN ISO 3741 at A7W45 (EN 12102).

12) Sound power level measured according to EN ISO 3741.

12

R404A

1.60

Scroll

400

4.4

0.6

3/6/9/12/15

17

16 3 /20 4 /25 5 /25 6 /

25 7 /30 8 /35 9

230

5.7

0.6

1.5/3/4.5

28

32 3 /40 4 /50 5

4.06

3.35

11.3

3.4

–20

20/–25

55/20

180

Danfoss assumes no responsibility for any errors found in the catalogues, brochures and any other printed material. Danfoss retains the right to make changes to their products, including products that have already been ordered, without prior notice, as long as these changes can be carried out without changing predetermined specifications. All trademarks in this material belong to respective companies. Danfoss and the

Danfoss logo are trademarks that belong to Danfoss A/S. All rights reserved. DHP-AL/March 2010

VDBMH602

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement