MAKING MODERN LIVING POSSIBLE

Danfoss Heat Pump

DHP-A

Air/water heat pump that provides heating and hot water.

DANFOSS HEAT PUMPS

VDBMA802

Danfoss DHP-A is an air/water heat pump that uses new innovative technology to operate at the highest possible annual efficiency. This means you can get

75% of your energy consumption for free – using renewable energy stored in the outdoor air. This provides a sustainable and environmentally friendly heating solution.

The integrated hot water tank incorporates our patented

TWS* technology, producing hot water faster and at higher temperatures than with traditional technology.

Defrosting is done automatically only on demand which further boosts efficiency.

DHP-A operates at a low sound level and can be controlled and monitored via the Internet. The controller is advanced but very user friendly.

* Tap Water Stratificator, our patented technology developed to stratify hot

water in a tank to ensure that heat is used optimally.

910

1

2

300

DANFOSS DHP-A

Connection

1 Brine in, 28 Cu

2 Brine out, 28 Cu

910

2 1

1

2

300

Connection

The brine pipes can be connected on either the left or right-hand sides of the heat pump.

2 1

2 Brine out, 28 Cu

3 Lead-in for incoming power supply,

sensors and communication cable

4 Heating system supply line,

22 Cu: 6-10 kW, 28 Cu: 12 kW

5 Heating system return line,

22 Cu: 6-10 kW, 28 Cu: 12 kW

6 Expansion pipe, 22 Cu

7 Hot water pipe, 22 Brass

8 Cold water pipe, 22 Brass

9 Expansion outlet brine circuit,

DN25 int.

10 Temperature and pressure valve

1175

5

7 8

10

6

3

9

4

300

250

2

1

455

596

40±10

DHP-A

Refrigerant

Compressor

Electrical data

3-N ~50Hz

Type

Amount

Type

Main supply

Rated power compressor

Rated power, circulationpumps/fan

Auxiliary heater, 5 steps

Start current

Circuit breaker

Electrical data

1-N ~50Hz

Main supply

Rated power compressor

Rated power, circulationpumps/fan

Auxiliary heater, 3 steps

Start current

Circuit breaker

Performance COP 1

COP 2

Heating capacity 2

Power input 2

Lowest outdoor temperature allowed for compressor start

Max/min temperature Cooling circuit

Heating circuit

Water heater Water volume

Anti freeze media 10

Indoor unit

Outdoor unit

Dimensions LxWxH

Weight empty

Weight filled

Sound power level 11

Dimensions LxWxH

Weight

Sound power level, low/high 12

Max. pipe length (Cu pipe Ø 28 mm between heat pump and outdoor unit)

The measurements are performed on a limited number of heat pumps which can cause variations in the results. Tolerances in the measuring methods can also cause variations.

kg

Volt kW

W kW

A

A

Volt kW

W kW

A

A

°C

°C l kW kW

°C mm kg kg dB(A) mm kg dB(A) m

6

R404A

0.95

Scroll

400

2.0

0.4

3/6/9/12/15

14

10 3 /16 4 /20 5 /20

25 7 /25 8 /30 9

6 /

230

3.3

0.4

1.5/3/4.5

58

25 3 /32 4 /40 5

3.88

3.26

5.90

1.8

–20

20/–25

55/20

180

690x596x1845

260

440

42.5

630x1175x1245

94

53/63

210 (105+105)

1) At A7W35 Δ10 warm side (excluding circulation pumps and outdoor unit).

2) At A7W35 according to EN 14511 (including circulation pumps and outdoor unit).

3) Heat pump with 3 kW auxiliary heater (1-N 1.5 kW).

4) Heat pump with 6 kW auxiliary heater (1-N 3 kW).

5) Heat pump with 9 kW auxiliary heater (1-N 4.5 kW).

6) 12 kW auxiliary heater (compressor off).

8

R404A

1.45

Scroll

400

2.3

0.6

3/6/9/12/15

25

16 3 /16 4 /20 5 /20

25 7 /25 8 /30 9

6 /

230

4.2

0.6

1.5/3/4.5

76

25 3 /32 4 /40 5

4.06

3.45

7.96

2.3

–20

10

R404A

1.50

Scroll

400

3.6

0.6

16

3/6/9/12/15

29

3 /16 4 /20 5 /20 6 /

25 7 /30 8 /35 9

230

5.4

0.6

1.5/3/4.5

97

32 3 /40 4 /50 5

4.21

3.29

9.85

3.0

–20

20/–25

55/20

20/–25

55/20

180 180

Ethylene glycol + Water solution with a freezing point below –30°C

690x596x1845

260

440

47.7

630x1175x1245

94

53/63

690x596x1845

260

440

45.5

630x1175x1245

94

54/67

131 (65+65) 70 (35+35)

690x596x1845

268

448

48.1

630x1175x1245

94

54/67

76 (38+38)

7) 15 kW auxiliary heater (compressor off).

8) Heat pump with 12 kW auxiliary heater.

9) Heat pump with 15 kW auxiliary heater.

10) Propylene glycol or ethanol may not be used.

11) Sound power level measured according to EN ISO 3741 at A7W45 (EN 12102).

12) Sound power level measured according to EN ISO 3741.

12

R404A

1.60

Scroll

400

4.4

0.6

16

3/6/9/12/15

32

3 /20 4 /25 5 /25 6 /

25 7 /30 8 /35 9

230

5.7

0.6

1.5/3/4.5

108

32 3 /40 4 /50 5

4.06

3.35

11.3

3.4

–20

20/–25

55/20

180

Danfoss assumes no responsibility for any errors found in the catalogues, brochures and any other printed material. Danfoss retains the right to make changes to their products, including products that have already been ordered, without prior notice, as long as these changes can be carried out without changing predetermined specifications. All trademarks in this material belong to respective companies. Danfoss and the

Danfoss logo are trademarks that belong to Danfoss A/S. All rights reserved. DHP-A/September 2009

VDBMA802

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement