BD350GH Direct Current Compressor R134a 24V 102Z BD350GH Application R134a SUCTION CONNECTOR Blue stripe Code number (without electronic units) 8634 Barcode on white background General MADE IN GERMANY Grey background 102Z3016 Electronic unit 3016 serial number N 1297 Approvals single: 101N0710, 36 pcs: 101N0711 Approvals e4, CE, C-Tick Compressors on pallet 125 Application Application S = Static cooling normally sufficient O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufficent – = not applicable in this area LBP/MBP/HBP Evaporating temperature Voltage range °C -25 to 15 VDC 19.6-31.5 Max. condensing temperature continuous (short) °C 60 (70) Max. winding temperature continuous (short) °C 125 (135) Cooling requirements Application LBP MBP HBP 32°C S S S 38°C S S S 43°C S S S Remarks on application: Motor Motor type Variable speed Resistance, all 3 windings (25°C) Ω 0.1 Displacement cm3 5.08 Oil quantity (type) cm3 280 (polyolester) Design Maximum refrigerant charge Free gas volume in compressor Weight - Compressor/Electronic unit g 400 cm3 1690 kg 7.9/0.3 35 70 100 ø16 ø9 Battery protection settings Voltage Min. value Default Max. value Cut out (0.1 steps) VDC 19.0 21.1 27.0 Cut in diff. (0.1 steps) VDC 0.5 3.9 10.0 170 178 186 204 C D 215 178 E Dimensions B 169 B1 – – location/I.D. mm | angle C 6.2 | 90° Process connector location/I.D. mm | angle D 6.2 | 31.5° Discharge connector location/I.D. mm | angle E 5.0 | 28° 78 June 2007 73 30 51 20° ° 8630 66 ±0.09, on 5.0 +0.12/+0.20 45° Remarks I.D. mm 128 Connector tolerance 157 B2 Suction connector A B 105 108 173 123 mm A ° 31.5 28° Height 95 117 DEHC.ED.100.O1.02/2 Capacity (EN 12900 Household/CECOMAF) rpm \ °C -25 -23.3 -20 -15 -10 2,500 84.7 93.7 113 147 188 3,000 101 112 136 176 225 3,500 114 126 152 198 254 4,000 126 139 169 220 282 -6.7 219 262 296 329 -5 236 283 319 355 0 292 351 396 440 24V DC, fan cooling F1 5 7.2 10 358 390 434 430 468 521 485 528 588 540 588 654 watt 15 520 625 706 786 Capacity (ASHRAE LBP) rpm \ °C -25 -23.3 2,500 105 116 3,000 126 139 3,500 141 156 4,000 156 173 -6.7 271 325 366 407 -5 292 351 395 440 0 363 435 491 546 24V DC, fan cooling F1 5 7.2 10 445 485 539 534 582 648 602 656 731 670 731 814 watt 15 648 779 879 979 0 152 186 217 248 24V DC, fan cooling F1 5 7.2 10 168 175 184 206 215 226 241 251 264 276 288 303 watt 15 200 245 288 330 -20 140 168 188 209 -15 182 219 246 273 -10 233 279 314 349 Power consumption rpm \ °C -25 -23.3 2,500 77.4 81.8 3,000 95.5 101 3,500 109 115 4,000 122 129 -20 90.8 112 128 144 -15 105 129 149 169 -10 120 148 171 194 -6.7 130 160 186 212 -5 136 167 194 221 Current consumption rpm \ °C -25 -23.3 2,500 3.23 3.41 3,000 3.98 4.20 3,500 4.52 4.79 4,000 5.07 5.38 -20 3.78 4.66 5.34 6.02 -15 4.38 5.39 6.21 7.03 -10 5.01 6.15 7.12 8.10 -6.7 5.43 6.67 7.75 8.82 -5 5.66 6.95 8.08 9.20 24V DC, fan cooling F1 A 0 5 7.2 10 15 6.32 7.00 7.29 7.67 8.33 7.76 8.58 8.94 9.40 10.21 9.05 10.03 10.46 11.01 11.98 10.34 11.48 11.99 12.63 13.75 W/W 15 2.60 2.55 2.45 2.38 W/W 15 3.27 3.20 3.08 2.99 COP (EN 12900 Household/CECOMAF) rpm \ °C -25 -23.3 -20 -15 2,500 1.09 1.15 1.25 1.40 3,000 1.06 1.11 1.21 1.37 3,500 1.05 1.09 1.19 1.33 4,000 1.03 1.08 1.17 1.31 -10 1.56 1.53 1.48 1.45 -6.7 1.68 1.64 1.59 1.55 -5 1.74 1.70 1.65 1.61 0 1.93 1.88 1.82 1.77 24V DC, fan cooling F1 5 7.2 10 2.13 2.23 2.36 2.09 2.18 2.31 2.01 2.10 2.22 1.96 2.05 2.16 COP (ASHRAE LBP) rpm \ °C -25 -23.3 2,500 1.36 1.42 3,000 1.32 1.38 3,500 1.30 1.36 4,000 1.28 1.34 -10 1.95 1.90 1.85 1.81 -6.7 2.09 2.04 1.98 1.93 -5 2.17 2.12 2.05 2.00 0 2.40 2.35 2.27 2.22 24V DC, fan cooling F1 5 7.2 10 2.67 2.79 2.95 2.61 2.73 2.89 2.52 2.63 2.79 2.45 2.56 2.71 -20 1.55 1.51 1.48 1.45 -15 1.74 1.70 1.66 1.62 Operational errors Error code 6 Error type Can be read out in the software Tool 4 Cool™. Thermostat failure (If the NTC thermistor is short-circuit or has no connection, the electronic unit will enter manual mode). 5 Thermal cut-out of electronic unit (If the refrigeration system has been too hea vily loaded, or if the ambient temperature is high, the electronic unit will run too hot). 4 Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,850 rpm). 3 Motor start error (The rotor is blocked or the differential pressure in the refrigeration system is too high. 2 Fan over-current cut-out (The fan loads the electronic unit with more than 1.8Apeak). 1 Battery protection cut-out (The voltage is outside the cut-out setting). Wire Dimensions Size Cross AWG section Max. length* 24V operation [mm2] [Gauge] [m] [ft.] 2x4 2x6 2 x 10 1.5 2 4 4.92 6.60 13.12 11 9 7 *Length between battery and electronic unit DC line cord Communication gateway module 900 ±20 mm / 2000 ±20 mm / 5000 ±20 mm mech. Thermostat - option 2 8626-2 Fan – t° + optional - option 1 Fan + optional 2 x 6 mm2 / AWG 10 Terminal plug Power supply Temperature sensor NTC sensor type M800/5k/2% Main switch Fuse 2 x 0.325 mm2 / AWG 22 ø 5.0 mm max. NTC resistor 8633 18 ±3 mm 470 ±10 mm / 1000 ±10 mm / 1500 ±10 mm Accessories for BD350GH DC line cord, 900 mm DC line cord, 2000 mm DC line cord, 5000 mm Temperature sensor 470 mm Temperature sensor 1000 mm Temperature sensor 1500 mm Communication cable 1500 mm Communication cable 3000 mm Communication gateway module Note: each fan max. 40W Single pack 105N9542 105N9540 105N9538 105N9612 105N9614 105N9616 – – 105N9501 I - Pack 105N9543, 36 pcs 105N9541, 36 pcs 105N9539, 36 pcs 105N9613, 200 pcs. 105N9615, 100 pcs. 105N9617, 100 pcs. 105N9545, 100 pcs. 105N9547, 50 pcs. – Test conditions Condensing temperature Ambient temperature Suction gas temperature Liquid temperature Accessories for Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities Standard automoblie fuse DIN 7258 Main switch 8637 EN 12900/CECOMAF 55°C 32°C 32°C no subcooling BD350GH Ø: 16 mm Ø: 16 mm Ø: 16 mm 24V: 30A rated to min. 50A ASHRAE 54.4°C 32°C 32°C 32°C Code number 118-1917 118-1918 118-1919 Not deliverable from Danfoss Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. /2 DEHC.ED.100.O1.02 June 2007
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement