PART I - GENERAL
1.01 DESCRIPTION
The Contractor shall furnish materials, equipment and labor to furnish, install and test the pumping system complete with the pumps, motors, mounting bases, piping, valves and appurtenances, as indicated on the contract drawings and as herein specified.
1.02 INSTALLATION
The Contractor shall insure that the pumps and motors are properly installed with no pipe strain transmitted to the pump casing.
1.03 RESPONSIBILITY
To assure a properly integrated and compatible system, all equipment described in this section shall be furnished by the Pump
Manufacturer, who shall assume full responsibility for the proper operation of the pumps and associated equipment.
1.04 SUPERVISION
The Contractor shall arrange for the Pump Manufacturer to provide a factory-trained representative as required for the purpose of supervising installation, start-up, final field acceptance testing, and providing instruction to the owner's operating personnel in the proper operation and maintenance of the equipment in this section.
The work in this section is subject to the requirements of applicable portions of the following standards:
Hydraulic Institute Standards
OSHA Rules and Regulations
PART II - PRODUCTS
The pump shall be a centrifugal vertical close-coupled end suction pump, Aurora Pump Model 323 or pre-approved equal. Pre-approval must be obtained a minimum of ten days before bid date.
2.02 MATERIALS OF CONSTRUCTION
Casing........................Cast Iron (ASTM A48)
Impeller......................Bronze (ASTM B584)
Shaft.........................Stainless Steel (AISI 416)
Case Wear Ring................Bronze (ASTM B62)
Suction Flange Adaptor........Cast Iron (ASTM A48)
2.03 CASING
The casing will be of the end suction design with threaded suction inlet and threaded centerline discharge outlet. The casing shall have tapped and plugged holes for priming and draining. The casing bore shall be large enough to allow "back pullout" of the impeller without disturbing the casing or suction and discharge piping.(ACD) The casing shall be supported by
2.04 IMPELLER
The impeller shall be of the enclosed type, vacuum cast in one piece. It shall be finished all over, the exterior being turned and the interior being finished smooth and cleaned of all burrs, trimmings, and irregularities. The impeller shall be dynamically balanced. The impeller will be keyed to the shaft, and fastened with a washer, gasket and capscrew.
2.05 CASE WEARING RING
The pump casing shall be fitted with a case wear ring to minimize abrasive and corrosive wear to the casing. The wear ring shall be of the radial type, pressed fitted into the casing.
The stuffing box shall be integrally cast with a motor mounting bracket, and shall provide an adequate area for internal recirculation of the pumped fluid around the sealing medium. A tapped and plugged hole shall be provided for external flushing as required.
Shaft sealing shall be accomplished by means of a mechanical seal with a Ni-Resist seat, carbon washer, Buna-N elastomers, and stainless steel metal parts.
2.08 SHAFT
The impeller shall be direct-coupled to the motor shaft. The motor shaft shall be machined to provide a keyway, and drilled and tapped to accept the impeller fastener. Stub shafts are not acceptable.
2.09 SUCTION FLANGE ADAPTOR
The casing shall be fitted with a suction flange adaptor which will allow vertical alignment of the pump and motor. The suction flange adaptor will be gasketed for mounting to a tank or receiver.
2.10 MOTOR
The motor shall conform to the latest NEMA standards, and shall have the following characteristics:
Enclosure..................Open Drip Proof/TEFC/X-Proof
Number of Phases...........Three
Horsepower.................? hp
Each motor shall have a sufficient horsepower rating to operate the pump at any point on the pump's head-capacity curve without overloading the nameplate horsepower rating of the motor regardless of service factor. The motor shall have a service factor of 1.15. The service factor is reserved for variations in voltage and frequency.
PART III - PERFORMANCE
3.01 CONDITIONS OF SERVICE to:
The following conditions of service shall be strictly adhered constant)
Number of Units........................?
Type of Drive..........................? (variable or
Discharge Size.........................1 in, minimum
Suction Size...........................1.25 in, minimum
Design Capacity........................ US gpm
Design Head............................ ft
Efficiency at Design................... %, minimum
Rotative Speed.........................3500 RPM, maximum
Shut-off Head..........................52.3 ft, minimum
Driver Horsepower......................0.764 hp, minimum
NPSHR at Design........................ ft, maximum
3.02 INSPECTION AND FACTORY TESTS
Each centrifugal pump furnished under these specifications shall be tested at the factory to verify individual performance (VIP).
Certified copies of all test reports shall be submitted to the Engineer for approval prior to shipment. Each unit shall be hydrostatically tested in accordance with the Hydraulic Institute Standards.
3.03 INSTALLATION AND ACCEPTANCE TESTS
A. The pumping units shall be installed in accordance with the instructions of the manufacturer and as shown on the drawings by the
Contractor.
B. Installation shall include furnishing the required oil and grease for initial operation. The grades of oil and grease shall be in accordance with the manufacturer's recommendations.
NOTES: Teflon is a registered trademark of E.I. DuPont.
Additional information is available from any Aurora Pump authorized distributor.