CAS CCB Series Crane Scale - Tension Meter Owner's Manual
CAS CCB Series is an advanced digital weight indicator with a wide range of capabilities, making it suitable for various weighing applications. It features:
-
Programmable Functions: Allows customization to meet specific weighing needs.
-
Data Storage: Stores up to 2,500 weight measurements, providing a history of weighing data.
-
Automatic Storage: Automatically captures and stores weight data based on configurable settings.
-
Hold Function: Freezes the displayed weight for easy reading and recording, even when the weight is unstable.
-
Tare Function: Subtracts the weight of containers or packaging, ensuring accurate net weight measurements.
Advertisement
Advertisement
2
NOTE
(1) The unauthorized copying of some or all of this manual is prohibited.
(2) The information contained herein is subject to change without notice.
(3) If there are any questions such as wrong or missing parts of the contents listed in this manual, please contact us.
(4) To improve the product performance, functions can be changed with no notice.
(5) Please understand that CAS does not have responsibility for a demand related to loss, lost profit etc. caused by operating the product, regardless of the third clause.
This is warning & caution mark
This is hazard alert mark
This is useful information mark
3
CONTENTS
1. Precautions....................................................5
3. How to Use a Rechargeable Battery .........6
4. Description of Panels and Symbols ...........7
5. General Functions and Description ..........9
7. Calling the Stored Data .............................12
8. Setting Mode ...............................................14
9. Real Time Clock .........................................17
11. RS-232C Interface....................................19
13. Code Management...................................21
4
1. Precautions
Please be informed that we’re not responsible for any incident or mishap caused by partial modification of this product. To avoid such situation, customers need to contact our customer service team or system installation staff in advance, and any modification should be conducted under our surveillance.
Use only approved enhancements and batteries. Do not connect incompatible products. Use only batteries, chargers, adaptor, and enhancements approved by
CAS for use with this particular model.
The use of any other types may invalidate any approval or warranty, and may be dangerous. For availability of approved enhancements, please check with your dealer.
Do not install the product in strong direct sunlight and dust.
Please confirm that the local voltage is correct for the power adapter.
Do not use inflammable substances for cleaning.
Avoid sudden changes of temperature if possible
Do not use the product in a place with a high-voltage current or severe electronic noise.
Do not use the product in a place with severe vibration.
Do not put too much pressure to keys.
Avoid from the shock of excessive weight.
2. Introduction
ZigBee wireless communication
Long battery lifetime by one time charging
Weight storage: 2,500
Item & client management: each 70
Standard RS232C
Automatic storage function
5
3. How to Use a Rechargeable Battery
Use only approved power adaptor and batteries.
Do not connect incompatible products.
Use only batteries, chargers, adaptor, and enhancements approved by
CAS for use with this particular model.
The use of any other types may invalidate any approval or warranty, and may be dangerous. For availability of approved enhancements, please check with your dealer.
Step1. Check the power adaptor voltage is (DC 5V, 1A).
Step2. Connect the charging jack to the port from adaptor.
Step3. If adaptor is still being charged, the RED lamp is on.
Step4. If a charging is completed, the GREEN lamp is on.
Step5. The battery charging time takes about 6~8 hr.
(Charging time is subject to be changed according to battery condition.)
6
4. Description of Panels and Symbols
SUM
HOLD
DISPLAY
Indicates weight and status
Displayed when the weight is stable
Displayed when the weight is minus
Displayed when a battery has to be recharged
Displayed when you press SUM key
Displayed when you press HOLD key to weight moving or alive
TARE
ZERO
CHARGE
Displayed when tare weight is stored
Displayed when the weight is zero
Indicates the weighing unit
Light up when power adaptor is connected
7
KEYBOARD
Turn on and off the scale.
Use confirm weight storage
Used to turn on and off the backlight / hold function
Return the display to zero
Used to weigh an item by using the container
Used to change unit
Designated printing form is printed
Used to print overall total weight
Used to accumulate the weight
Used to register ID code
Used to register Client code
Used to enter the setting mode
Used to initialize the accumulated weights
Used to save weighing data by manual
Used to save current condition and exit in Test, Setting mode
8
5. General Functions and Descriptions
5.1. Zero function
Use to correct drifted zero value when the scale is unloaded, and motion is not detected.
This function works when ZERO KEY is pressed, and the ZERO mark turns on.
5.2. Tare function (Refer to setting mode F12)
The function is used to display a net value with the container weight subtracted from the total weight, if you place an object into a container to weigh it.
Step1.
Place the tare on the weighing tray.
Step2.
Press the TARE key to store the tare weight after the STABLE mark turns on and then the display changes to net.
To escape this function, remove everything from the scale, and press the TARE key.
Then the TARE lamp will turn off and this function is terminated.
The sum weight of the tare and any item on a scale cannot exceed maximum capacity.
When zeroing with the ZERO key, tare is cleared.
5.3. Preset tare function (Refer to setting mode F12)
When you already know the tare weight, press TARE key and input tare weight using by numeric keys and memorize it by pressing ENTER key.
5.4. Hold function (F13 of setting mode must be set to 1)
■ Manual hold function
Step1. Press F(hold) key after loading a thing.
Step2. Sequentially the message of is shown with appearing the average weight.
Step3. To escape the manual hold mode, remove everything from a weighing tray, or press the F(hold) key. Then, HOLD mark will be turns off and the scale changes from a hold mode to a normal mode.
■ Automatic hold function
Step1. Press F(hold) key when the scale is empty. (Initial zero state)
Step2. The display will indicate and HOLD mark will be turns on.
Step3. After loading a thing, a display shows automatically and average weight
will appear.
Releasing the data when a displayed value smaller than initialization hold weight.
Step4. To escape the automatic hold mode, when zero point is on, press F(hold) key
Then the message of is displayed and HOLD mark will be turns off and normal weighing mode is reverted.
9
5.5. Print function
If PRINT key is pressed, the print format you chose in set mode (Refer to setting mode F03) is to be printed.
5.6. Overall total print function
If TOTAL key is pressed, “ ” is displayed and will be printed as shown below.
After printing is done, the total weight and count are reset.
- - - - - - - - - - - - - - - - - - - - - - - - - -
OVERALL-TOTAL
- - - - - - - - - - - - - - - - - - - - - - - - - -
DATE : 2008.11.25
TIME : 9:55
COUNT: 50
TOTAL: 760.0 lb
5.7. Item code registration
Step1. Press ITEM key.
Step2. Input the item code. The code range is from 0 to 69.
Step3. To escape from this mode, Press the ENTER key.
Refer to “8. Management of the Item & Client”
5.8. Item code registration
Step1. Press CLIENT key.
Step2. Input the client code. The code range is from 0 to 69.
Step3. To escape from this mode, Press the ENTER key.
Refer to “8. Management of the Item & Client”
5.9. Storage data clear
In weighing mode, you can clear storage data with press CLEAR key for 3 seconds.
Also, you can clear storage data using F09-1 of setting mode
5.10. Weight accumulation
Press SUM key to accumulate weight data when the STABLE mark is on.
And then the accumulated data is displayed.
After that, about 2 sec later, a weighing mode is reverted.
If you press CLEAR key, accumulated weights are cleared.
10
6. Weight Storage
6.1. Automatic storage – Peak data
Step1. Set the setting mode F10-1
Step2. Set the setting mode F11 (1d~9d) you set F11-5, the weight of 5division or less will not be automatically stored.
Step3. Input the client and item code.
If you don’t use client and item code, you can ignore this step.
Step4. Measure the weight and CRC-100 store the weight of the peak .
Data can be stored after the weight data enters the zero band range of F12.
6.2. Automatic storage – Hold data
Step1. Set the setting mode F10-2
Step2. Input the client and item code .
If you don’t use client and item code, you can ignore this step.
Step3. If you measure with Hold function, holding data is stored in the memory.
6.3. Manual storage
Step1. Set the Setting mode F10-0.
Step2. Input the client and item code.
If you don’t use client and item code, you can ignore this step.
Step3. Measure the weight.
Step4. Press * key when the STABLE mark is on.
Step5. The serial number and code (client & item) are displayed alternately.
(Serial number: client & item : )
Step6. Press * key to store and then is displayed and the weight is stored.
The capacity of memory is 25K. is displayed if it arrives at the capacity.
In this case, take backup memory to PC and execute a memory initialization.
6.4. Stored data check
Step1. Press CALL key and then is displayed. Enter your client code.
Step2. Storage value and sequence number are displayed .
Step3. Press ENTER key to check the stored value.
Step4 If you check the last data, is displayed. And then return to weighing mode after total weight of its client is displayed. if you press CLEAR key, return to weighing mode.
11
7. Calling the Stored Data
Step1. Press CALL key and then is displayed.
Step2. Press CALL key again and then is displayed.
Step3. Refer to the call method of the downside and press 1 to 6 key.
(1) By date
1 Press ENTER key after input to a year
2 Press ENTER key after input to a date (10:month 13:data)
3 If you press PRINT key, data is transmitted
(2) By serial number
1 Press ENTER key after input to the serial number
2 If you press PRINT key, data is transmitted
(3) By item code
1 Press ENTER key after input to item code
2 If you press PRINT key, data is transmitted
(4) By client code
1
2
Press the ENTER key after input to client code
If you press PRINT key, data is transmitted
(5) whole storage data
1 If you press PRINT key, data is transmitted
(6) By client, item code and date
1
2
3
4
5
Press the ENTER key after input to client code
Press ENTER key after input to item code
Press ENTER key after input to a year
Press ENTER key after input to a date (10:month 13:data)
If you press PRINT key, data is transmitted
12
(1)~(5) Print format (F06-1) (6) Print format (F06-1)
2014.10.13 12:30
S/N 0101 50.0 lb
CLIENT: CAS
ITEM : Weighing scale
2014.10.13 15:35
S/N 0119 30.5 lb
CLIENT: Samsung
ITEM : IC
-------------------------------------
CAS
Weighing scale
-------------------------------------
2007.10.13 09:51
S/N 0038 35.8 lb
2008.01.01 12:30
S/N 0101 50.0 lb
-------------------------------------
ITEM TOTAL 85.8 lb
CONFIRM :
-------------------------------------
(1)~(6) PC format (F06-2)
Start code Year, month, day, time
S S 1 4 1 0 1 3 1 2 0 0 blank
Serial number
0 0 0 1 blank
Item
ASCII 20 byte blank
Client
ASCII 20 byte blank
Weighing data
0 0 0 1 2 . 0 blank CR LF
13
8. Setting Mode
8.1. How to enter
Press the SETUP key. Then it turns into the setting mode.
8.2. Function menu
■ F01: Sending data to PC or printer (0~6) ▶ Initial value: 0
Value Description
1
2
3
4
Command mode
If the device ID is received from PC, it transmits the weighing value
Transmission in an state of stable and unstable
Transmission only in stable state
Manual print (With PRINT key)
6 Automatic hold value print
Refer to data format of “9. RS232C Interface”
■ F02: Device ID (0~9) ▶ Initial value: 0
Value Description
0 Device ID 0
5 Device ID 5
9 Device ID 9
■ F03: Printing format (0,1) ▶ Initial value: 0
Value
0
Description
Form 0 (Date, weigh No., Item, Client, Weight)
1 Form 1 (Date, weigh No., Weight)
[FORM 0] [FORM 1]
2014.10.13 12:30
NUMBER: 001 50.0 lb
CLIENT: CAS
ITEM : Weighing scale
2014.10.13 12:30
NUMBER: 001 50.0 lb
2014.10.13 12:31
NUMBER: 002 30.5 lb
1 4
■ F04: Number of copies (0,1) ▶ Initial value: 0
Value Description
0 A sheet of paper
1 Two sheet of paper
■ F05: Printer type (0,1) ▶ Initial value: 0
Value Description
■ F06: Method sending of storage data (0,1) ▶ Initial value: 0
Value Description
Refer to data format of “9. RS232C Interface”
■ F07: Initialization of item code (0,1) ▶ Initial value: 0
Value Description
0 Maintain current item code
1 Initialization
■ F08: Initialization of client code (0,1) ▶ Initial value: 0
Value Description
0 Maintain current client code
1 Initialization
■ F09: Storage data clear (0,1) ▶ Initial value: 0
Value Description
0 Maintain current storage data
1 Clear weighing data storage data
In weighing mode, you can clear storage data with press CLEAR key for 3 seconds.
15
■ F10: Automatic storage (0~2) ▶ Initial value: 0
Value Description
0 Not used (By manual)
1
2
Store the peak weight data by automatic
Store the average hold data by automatic
■ F11: Zero band (0~9) ▶ Initial value: 0
Value
0 0d
Description
5
9 less than or equal to 5d less than or equal to 9d
Data can be stored after the weight data enters the zero band range.
■ F12: Preset tare function (0,1) ▶ Initial value: 0
Value Description
■ F13: F key function (0,1) ▶ Initial value: 0
Value
0 Backlight ON/OFF key
Description
■ F14: Backlight conditions (0~2) ▶ Initial value: 0
Value Description
1 Automatic ON/OFF (Weighing: ON / Zero: OFF)
16
9. Real Time Clock
When the controller is power off press ON/OFF key while pressing PRINT key, Then this mode is started.
Display Description
Year input readiness.
Modify the year by pressing the numerical keys and press ENTER key
Month & date input readiness.
Modify the date by pressing the numerical keys and press ENTER key
Time input readiness.
Modify the time by pressing the numerical keys and press ENTER key
The end
1 7
10. Test Mode
When the controller is power off press ON/OFF key while pressing ZERO key,
Then this mode is started.
■ TEST 1: Display test
Display Description Key
ENTER :
To next menu
TEST 1 runs automatically.
■ TEST 2: Keyboard test
Display Key
ENTER :
To next menu
Other key :
Perform test
Key number
Key Number
13
01
04
07
11
Key
Description
Press the key to be test and the No. and code corresponding to the key is displayed.
Number Key Number
14
02
05
08
10
03
06
09
12
1 8
11. RS-232C Interface
11.1. Specifications
■ Method: Full-duplex, asynchronous transmission format
■ Baud rate: 9600 bps
■ Data bit: 8 bits
■ Parity bit: Non parity
■ Start bit: 1bit / Stop bit: 1bit
■ Adaptable connector (D-SUB 9P FEMALE)
2P 3P 5P
TXD RXD GND
11.2. Data format
When data is sent to computer? Set in setting mode (F01)
Header 1 Header 2 ID Data Unit Terminator
S T , G S , , 0 . 0 l b C
R
Lamp status
Header 1
Header 2
ID
Lamp status
ST
US
OL
HD
Stable weight data (0x53) (0x54)
Unstable weight data (0x55) (0x53)
Overload (0x4F) (0x4C)
Hold weight data (0x48) (0x44)
GS
NT
Gross data (0x47) (0x53)
Net data (0x4E) (0x54)
Command address ID is selected in F02 (If ID is 1, 0x31 is sent)
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
1 Stable 1 Hold 1 Net Tare Zero
L
F
Data
Unit
Terminator
Example 3) -13.5 lb ‘-’, ‘ ’, ‘ ’, ‘ ’, ‘1’, ‘3’, ‘5’, ‘ ’
Kg g
(0x6B) (0x67)
(0x20) (0x67) lb
C
R
L
F
(0x6C) (0x62)
(0x0D) (0x0A)
19
12. Wireless Pairing
Step Operation & Description
1
How to enter the pairing mode
1) CCB crane scale
When the display is off, press ON/OFF key while pressing * key.
When “ = ”(Firmware version) is displayed, press kg/lb key.
Then, “ ” is displayed.
2) CRD-F wireless display
Press the ON/OFF key to power on and immediately press kg/lb key.
And press the kg/lb key again.
Then, “ ” is displayed.
3) CRC-100 controller
When the display is off, press ON/OFF key while pressing ENTER key.
When “ = ”(Firmware version) is displayed, press3 key.
Then, “ ” is displayed.
4) CRC-200 wireless dongle
Press the SET KEY for the 5 seconds with the power on that connected.
Then, the green light is blinking.
2
Pairing
When “ ” is displayed at both products, if you press * key of CCB crane scale, pairing will finish.
Please check “ ” message at both products.
If ending message is not appear, please repeat the pairing.
20
13. Code Management
13.1. Using PC
1) Connect the CRC-100 and PC with a serial cable.
2) When the display is off, press ON/OFF key while pressing * key then “ is displayed.
3) Start the CRC-100 PC Sync.
4) Confirm the PC port and click the CONNECT
”
5) Input the company name (Company name to be printed at first line)
6) Input the client name and click the INSERT (Code range: 0~69)
21
Delete the client: Input client code and click DELETE
Change the client: Input client code, name and click INSERT
7) Item and client management method are the same
Initialization: Click CLEAR
22
8) PC → CRC-100: Click SYNC
Current list stored in Excel file: Click File Save
Open the Excel file: Click File Open
9) CRC-100 → PC: Press SETUP key of CRC-100
23
13.2. Using itself function
No Display Description
1
Item text input:
When the display is off, press ON/OFF key while pressing ITEM key.
Client text input:
When the display is off, press ON/OFF key while pressing CLIENT key
► Input the item or client code and press ENTER key.
Company text input:
When the display is off, press ON/OFF key while pressing SETUP key.
► Press ENTER key.
Designate as follows if you want to add item name “IRON" on item code.
2 00 Data start (032 is start code) ► Press CALL key
3 01 ASCII Character : ‘I’(073) ► Press CALL key
4 02 ASCII Character : ‘R’(082) ► Press CALL key
5 03 ASCII Character : ‘O’(079) ► Press CALL key
6 04 ASCII Character : ‘N’(078) ► Press CALL key
7 05 Data end (255 is end code)
8 Press ENTER key
► Press CALL key
The range of item & client coordinate is from 0 to 21. (Company: 0 to 71)
2 4
ASCII CODE
ASCII CODE ASCII CODE ASCII CODE ASCII CODE ASCII CODE ASCII CODE
SP 32
! 33
“ 34
# 35
$ 36
% 37
& 38
‘ 39
(
)
40
41
* 42
+ 43
,
-
44
45
. 46
/ 47
0
1
2
3
4
5
6
7
8
9
:
;
<
=
>
?
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
@ 64
A
B
C
D
E
F
G
H
I
65
66
67
68
69
70
71
72
73
J 74
K 75
L 76
M 77
N 78
O 79
P 80
Q 81
R
S
T
U
V
82
83
84
85
86
W 87
X
Y
Z
[
\
]
88
89
90
91
92
93
^ 94
_ 95
`
a
b
c
d
e
f
g
h
i
j
96
97
98
99
100
101
102
103
104
105
p
q
r
s
t
u
v
w
x
y
106 z
k 107 {
112
113
114
115
116
117
118
119
120
121
122
123
l 108 |
m 109 }
124
125
n 110 ~ 126
o 111 END 255
25
14. Specifications
■ General specification
Display 5 digit LCD (Height: 15mm) & Backlight
Enclosure Engineering plastic
Keyboard
Battery life
Operating temperature
Operating humidity
Product weight
Power
Charging adapter
■ Wireless specification
Wireless method
RF frequency range
15 Tact switch
Approx. 90hr
-20 ℃ ~ 60 ℃
85% R.H. (No condensation)
Approx. 450g
3.7V 4A Lithium polymer battery
AC/DC Adapter 5V 1A
Output power
Channel width
Frequency offset
Transmit data rate
Receiver sensitivity
Maximum input level
RF In/out impedance
Spurious(2nd harmonics)
Radio link effective range
ZigBee
2400 ~ 2483.5 MHz
Max. 4dBm
2 MHz
< ±30ppm
250Kbps,500Kbps
-99dBm (PER <1%)
0dBm
50 ohm (TXRF, RXRF)
< -30dBm
Approx. 100M (Open space)
26
■ Dimensions [mm]
15. Check Message
Code Description
The gross weight of scale is over maximum capacity.
Don’t load the article at scale whose weight is heavier than the maximum capacity
When the scale and CRC-100 doesn’t communicate, this is displayed.
Check the radio link effective range.
When memory capacity is exceeded, this is displayed.
Take backup to PC and execute a memory initialization.