2
NOTE
(1) The unauthorized copying of some or all of this manual is prohibited.
(2) The information contained herein is subject to change without notice.
(3) If there are any questions such as wrong or missing parts of the contents listed in this manual, please contact us.
(4) To improve the product performance, functions can be changed with no notice.
(5) Please understand that CAS does not have responsibility for a demand related to loss, lost profit etc. caused by operating the product, regardless of the third clause.
This is warning & caution mark
This is hazard alert mark
This is useful information mark
3
CONTENTS
1. Precautions....................................................5
2. Main Features...............................................5
4. Description of Panels and Symbols ...........7
6. General Functions......................................11
8. Setting Mode ...............................................13
9.
Infrared Remote Controller .....................16
11. RS-232C Interface....................................17
12. Real Time Clock.......................................18
4
1. Precautions
Please be informed that we’re not responsible for any incident or mishap caused by partial modification of this product.
To avoid such situation, customers need to contact our customer service team or system installation staff in advance, and any modification should be conducted under our surveillance.
Do not connect incompatible adaptor.
Use only adaptor approved by CAS for use with this particular model.
The use of any other types may invalidate any approval or warranty, and may be dangerous.
For availability of approved enhancements, please check with your dealer.
Don’t install the CRD-F series in direct sunlight.
Avoid sudden temperature changes, vibration, wind, water or dirt.
Avoid from the shock of excessive weight.
Place the scale away from water.
Use away from heavy R.F noise.
Do not disassemble or modify this product.
2. Main Features
Water proof: IP65
ZigBee w ireless communication
Interface with crane scale & wheel load scale & indicator
Standard remote control
Tilt and swivel mount bracket
Touch key
5
3. Technical Specifications
◆ General specifications
Display 2300F: FND (2.3 inch) / 3000F: FND (3 inch)
Display lamp Zero, Tare, Hold, Stable, Power
Touch key
Case material
Zero, Tare, Hold, Power
Engineering plastic
Temperature range -20 ℃ ~ 60 ℃
Product weight 2300F: Approx. 1.5kg / 3000F: Approx. 2.2kg
Adaptor
Option 1 (OP-01)
12V 1A
RS232C, RTC(Real time clock), 2solid state relays and 4inputs
Use the vehicle power (12~24V ) Option 2 (OP-02)
◆ Product size
1) CRD-2300F
2) CRD-3000F
6
4. Description of Panels and Symbols
DISPLAY
Displays weight or messages
Indicates that the weight to be in stable condition
ZERO lamp Indicates that scale is stable and at zero
Kg/lb lamp Unit conversion operating lamp
TARE lamp Indicates that scale is currently using a tare
Power lamp Power lamp kg lb Indicates the weighing unit
KEYBOARD
Turn on and off the product
Return the display to zero
Used to change unit
Used to weigh an item by using the container
7
5. Installation
12V
GND
TX3
RX3
GND
Power adaptor + (RED)
Power adaptor – (BLACK)
Not used (Extra RS232C TXD)
Not used (Extra RS232C RXD)
Not used (Extra RS232C GND)
8
POWER
ZERO
TARE
HOLD
GND
EVCC+
OUT1
EVCC+
OUT2
RX1
GND
Not used
TX2 RS232C TXD (OP-01)
RX2
GND
EX+
RS232C RXD (OP-01)
RS232C GND (OP-01)
EX-
SIG+
SIG-
GNG
Not used
External key 4 contact / 4inputs (OP-01)
“HOLD” mark is the same as “kg/lb”
2 solid state relays contact (OP-01)
9
1) External input circuit
External inputs are interlocked with the touch keys.
2) Solid state relay circuit
Maximum load (AC, DC 350V /130mA)
Output conditions
Output
OUT2 ON (low limit)
OUT1 ON (high limit)
OUT1,2 OFF
Conditions
Low limit< Measured value ≤ High limit
High limit < Measured value
Measured value ≤ Low limit
10
6. General Function
6.1. Zero function
Use to correct drifted zero value when the scale is unloaded, and motion is not detected.
This function works when ZERO KEY is pressed, and the ZERO LAMP is on.
6.2. Setting Tare Weight Function
Press the TARE KEY. Then, the scale will memorize the weight of the tare and will display zero value “0”kg. The TARE LAMP will be on.
To escape this function, remove everything from the scale, and press the TARE KEY.
Then, the TARE LAMP will be off and this function is terminated.
6.3. Hold Function
This function will only work with IR remote control.
Also, F08 of CCB setting mode must be set to 4.
■
Automatic hold
- Press * KEY when the scale is empty (Initial zero state).
- The weight display will indicate . HOLD LAMP is on.
- After loading a thing, if the weight turns stable then, a display shows and
average weight will appear.
- The weight of a loaded thing is displayed.
- To escape the automatic hold mode, when zero point is on, press
*
KEY.
Then, the message of is displayed and HOLD LAMP is off and normal weighing
mode is reverted.
■ Manual hold
- Press
*
KEY loading a thing.
- This message of is displayed and sequentially the message of is shown with appearing the average weight.
- The weight of a loaded thing is displayed.
- To escape the manual hold mode, remove everything from a hook, or press the
*
KEY.
Then, HOLD LAMP will be off and the scale changes from a hold mode to a normal mode.
11
7. Test Mode
(1) How to enter this mode
Press the
ON KEY
to power on and immediately press
ZERO KEY
to enter test mode.
(2) Testing Menu (TEST 1- TEST 2)
■
TEST 1 : Keyboard Test
Key
Remote
Control
Display Description
Press a keyboard that you want to test, and then the display message will be shown.
If press a TARE KEY, move on TEST 2.
■ TEST 2 : Display Test
Display Description
TEST 2 runs off automatically and a display is on.
If press the TARE KEY, move on normal mode
12
8. Setting Mode
8.1. How to enter this mode
Press the ON KEY to power on and immediately press TARE KEY.
And press the TARE KEY again.
8.2. Keyboard
■ : Use to set up an initial zero value (0).
(F12, F13: Used to move the input value to the left or right by one place)
■ : Use to add a value of “1” from existing value.
■ : Use to save an inputting value and to move on next menu.
8.3. Menus
■ F01: PC / Printer connection (0~2)
Description Setting Menu
F01-0 Wireless
F01-1 RS232C
F01-2 Wireless & RS232C
In case of F01-0/2, you used the CRC-200 (Wireless dongle)
Weighing data will be sent by according to set in F02.
■ F02: Function * key (Remote controller) (0~2)
Setting Menu
F02-0
Description
Operation is equal to the * key of the master
F02-1
F02-2
Send data command key (Print format)
Send data command key (22bytes format)
■ F03: Item number (Identification number of each item) (0~9)
Setting Menu Description
13
■ F04: Print line feed (0~9)
Setting Menu
F04-0
F04-5
F04-9
1 line feed
6 line feed
10 line feed
Description
■ F05: Print form (0,1)
Setting Menu
F05-0
F05-1
Description
Form 0 (weigh No., Item No., weight)
Form 1 (Serial No., Item No., weight)
When the F02-1 is selected, this form is printed.
The weigh No. is not saved.
[FORM 0] [FORM 1]
2014.10.13 12:00
001, ID_9, 25 lb
■ F06: Initialization of serial number (0,1)
2014.10.13 12:00
SN_02, ID_9, 25 lb
Setting Menu Description
F06-0 Maintain number
F06-1 Initialization (starting from No.1)
■ F07: Auto transmit at stable (0~2)
Setting Menu Description
F07-1
F07-2
Send data at stable (Print format)
Send data at stable (22bytes format)
■ F08: Auto transmit at data hold (0,1)
Setting Menu Description
F08-1 used
The hold data will be sent by according to set in F07.
1 4
■ F09: Wireless connection of other company’s product (0~2)
Setting Menu Description
F09-1
F09-2
Product with 22bytes RS232C format
Product with 18bytes RS232C format
If you select F09-1 or F09-2, you must use the CRC-200 dongle at the scale.
■ F10: RS232C Stream mode (0,1)
Setting Menu Description
■ F11: High limit (not included weighing points)
Setting Menu
200
Description
20.0 lb (In case of one decimal point)
■ F12: Low limit (not included weighing points)
Setting Menu
100
Description
10.0 lb (In case of one decimal point)
15
9. Infrared Remote Controller
9.1. How to use
■ : Use to power on/off the CRD-F series
■ : Same as keyboard of CRD-F series
■ : Same as keyboard of CRD-F series
■ : Same as keyboard of CRD-F series
■ : Same as keyboard of CCB crane scale
■ : Used to add weights.
If press a
SUM KEY,
the sum of weights is displayed.
After that, about 2 sec later, a weighing mode is reverted.
Weight of less than 5 digits is not summed.
Maximum of sum weights is 99999, and if it exceeds the weights is initialized to zero.
9.2. Specification
List Description
Available Distance 6 m ~ 10 m
Available Angle 60°
Power 3V (1.5V AA 2 EA)
10. Wireless Specification
RF frequency range
Output power
Channel width
Frequency offset
2400 ~ 2483.5 MHz
Max. 4dBm
2 MHz
< ±30ppm
Transmit data rate
Receiver sensitivity
Maximum input level
RF In/out impedance
250Kbps,500Kbps
-99dBm (PER <1%)
0dBm
50 ohm (TXRF, RXRF)
Spurious(2nd harmonics) < -30dBm
Radio link effective range Approx. 100M (Open space)
16
11. RS-232C Interface
1) Type : EIA-RS-232C
2) Method : Full-duplex, asynchronous transmission Format
① Baud rate: 9600 bps
② Data bit: 8 bits
③ Code : ASCII
3) Format (22bytes)
Header 1 Header 2 ID Data Unit Terminator
S T , G S , , 0 . 0 l b C
R
L
F
Lamp status
Header 1
Header 2
ID
Lamp status
ST
US
OL
HD
GS
Stable weight data (0x53) (0x54)
Unstable weight data (0x55) (0x53)
Overload (0x4F) (0x4C)
Hold weight data (0x48) (0x44)
Gross data (0x47) (0x53)
NT Net data (0x4E) (0x54)
Command address ID is selected in F02 (If ID is 1, 0x31 is sent)
Bit7
1
Bit6
Stable
Bit5
1
Bit4
Hold
Bit3
1
Bit2
Net
Bit1
Tare
Bit0
Zero
Data
Unit
Terminator
Example 3) -13.5 lb
Kg
‘-’, ‘ ’, ‘ ’, ‘ ’, ‘1’, ‘3’, ‘5’, ‘ ’
(0x6B) (0x67) g lb
C
R
L
F
(0x20) (0x67)
(0x6C) (0x62)
(0x0D) (0x0A)
1 7
12. Real Time Clock
1) How to enter this mode
Press the ON KEY to power on and immediately press kg/lb KEY.
And press the TARE KEY.
2) Keyboard
: Used to increase the setting constant one by one.
: Used to move the input value to the left or right by one place.
: Used to save the value and to move next menu.
Display Description
Year input readiness.
Modify the year by pressing the numerical keys and press TARE KEY
Month & date input readiness.
Modify the date by pressing the numerical keys and press
TARE KEY
Time input readiness.
Modify the time by pressing the numerical keys and press TARE KEY
The end
1 8
13. Wireless Pairing
Step Operation & Description
1
How to enter the pairing mode
1) CCB crane scale
When the display is off, press ON/OFF key while pressing * key.
When “ = ”(Firmware version) is displayed, press kg/lb key.
Then, “ ” is displayed.
2) CRD-F wireless display
Press the ON/OFF key to power on and immediately press kg/lb key.
And press the kg/lb key again.
Then, “ ” is displayed.
3) CRC-100 controller
When the display is off, press ON/OFF key while pressing ENTER key.
When “ = ”(Firmware version) is displayed, press3 key.
Then, “ ” is displayed.
4) CRC-200 wireless dongle
Press the SET KEY for the 5 seconds with the power on that connected.
Then, the green light is blinking.
2
Pairing
When “ ” is displayed at both products, if you press * key of CCB crane scale, pairing will finish.
Please check “ ” message at both products.
If ending message is not appear, please repeat the pairing.
19
14. Check Message
When a thing is over-weighed within the maximum weight value, the error message is displayed.
Do not weigh the thing whose the limit of a maximum weight value is exceeded.
If a load cell is broken, then the load cell has to be replaced.
Something wrong in a Load cell connection or in an A/D conversion.
Please contact us to resolve this technical problem.
☞ ☞ ☞ ☞
When the scale and CRD-F series does not communicate, this is displayed.
Confirm radio link effective range.
20
MEMO
21
MEMO
22
23