Multiplex Beer System Pressure Choker Calculator Installation Guide

Multiplex Beer System Pressure Choker Calculator Installation Guide
Beer system pressure and choker
calculator
For Blended Gas
Manitowoc Beverage Division
Manitowoc Foodservice Group
Line run length
0.00 Feet
X 0.07 # per foot
PLUS Rise from bottom of
keg to outlet of faucet
MINUS Fall from bottom of
keg to outlet of faucet
PLUS minimum 24” choker
If using Kyees tower
If using Kyees Chill Pak
If using bent tube assembly
in tower
0.00 Feet
X 0.5 # per foot
0.00 Feet
X 0.5 # per foot
0.00
+
0.00
-
0.00
+ 6.0
-- Choose One --- Choose One --
ADD
ADD
+ 4.8
+ 4.0
-- Choose One --
ADD
+ 3.0
Total initial resistance
=
6.00
If total initial resistance is 20 # or greater *, you have the Applied Keg Pressure and length of choker
tube. If initial resistance is less than 20 #, add additional choker as below. Yes
20.00
Minimum Pressure * 20 #
6.00
Minus Total initial resistance as calculated above
=
Equals initial additional resistance to add
Times 4
14.00
x4
=
56.00
Round up the number of initial inches choker tube to
add to the next 1” segment
Plus minimum choker length
Total amount of choker hose to use in the run with
=
20 # Applied Keg Pressure
* If your altitude is above 2,000 feet, add 1 # per 2000 feet or portion
thereof to the minimum pressure stated above.
0.00
56
Equals initial number of inches choker tube to add
RESET
+ 24"
80
PRINT
2100 Future Drive
P.O. Box 1868
Sellersburg, IN 47122-1868
Tel: 812-246-7000
Fax: 812-246-7026
www.manitowocbeverage.com
September 2005
Page 1 of 1