Multiplex CEV Metal Bonnet Installation Guide

Add to my manuals
4 Pages

advertisement

Multiplex CEV Metal Bonnet Installation Guide | Manualzz

Part Number 5031540

CEV Metal Bonnet Installation Instructions

CEV30

Parts Included in Kit No.: 5031536

Description

8-32 Self Tapping Countersink Screw

8-32 Self Tapping Screw

No.8 Course Thread Screw

115 Volt 60Hz Wiring Diagram Label

208-230 Volt 60Hz Wiring Diagram Label

220-240 Volt 50Hz Wiring Diagram Label

Key Switch Bracket

Metal Bonnet Assembly

Splash Panel

Condenser Bracket Assembly

Installation Instructions

Beverage Configuration Label (STD)

Beverage Configuration Label (Juice)

Beverage Configuration Label (5 VLV)

Beverage Configuration Label (Var VLV)

Part Number Qty

0900504

5011940

5013485

5029625

5029626

5029627

5031050

5031537

5031538

5031539

5031540

5012519

5013734

5027794

020001226

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1 of 4

CEV40

Parts Included in Kit No.: 020002844

Description

8-32 Self Tapping Countersink Screw

8-32 Self Tapping Screw

No.8 Course Thread Screw

115 Volt 60Hz Wiring Diagram Label

208-230 Volt 60Hz Wiring Diagram Label

220-240 Volt 50Hz Wiring Diagram Label

Key Switch Bracket

Metal Bonnet Assembly

Splash Panel

Condenser Bracket Assembly

Installation Instructions

Beverage Configuration Label (STD)

Beverage Configuration Label (Var VLV)

Part Number Qty

0900504

5011940

5013485

5029625

5029626

5029627

5031050

20002778

020002829

5031539

5031540

5013361

020002740

1

1

1

1

1

1

1

1

1

1

1

1

1

Revision-1

1A

1B

2A

2B

3A

3B

1C

CEV Metal Bonnet Installation Instructions

Figure 1

Figure 2

Figure 3

Part Number 5031540

3D

1D

2C

3C

2 of 4

Instructions

1) Disconnect or shut off power supply to

CEV unit. Failure to do so may cause electrical shock or injury .

2) Remove existing plastic merchandiser, light kit, bonnet wrap and rear panel assembly from existing unit. Remove existing condenser air filter from rear panel assembly. Clean air filter thoroughly and retain for reuse. Review service and install manual for further removal details

3) Disconnect wires from valve key switch.

Remove both L-shape brackets on each side of the valve mount cap ( 1A ) by removing the four 8-32 mounting screws

(two each side). Retain screws for reuse.

Remove existing key switch assembly from L-shaped bracket by removing the retaining nut. Retain key switch assembly for reuse. Reinstall two of the four 8-32 mounting screws ( 1B ) in bottom mounting slots on left and right sides of valve mount cap ( See Figure 1 ).

4) Remove drain pan ( 1D ) and the existing splash panel ( 1C ). Keep drain pan for reuse and discard splash panel ( See

Figure 1 ).

5) The new splash panel ( 2A ) will require the correct wiring diagram installed on back upper left side ( 2B ) and plumbing diagram on back upper right side ( 2C ) of panel. All voltage option wiring diagrams are provided along with all plumbing diagrams. Review unit serial tag to determine correct voltage wiring diagram to be applied on new splash panel ( See

Figure 2 ).

Revision-1

5B

5C

6B

6A

4B

CEV Metal Bonnet Installation Instructions

Figure 4

Figure 5

Figure 6

Part Number 5031540

3 of 4

4A

5A

4C

Instructions

6) Install new splash panel ( 1A ) by reinstalling the two 8-32 mounting screws. Reinstall drain pan ( 1D ) and attach any drain lines that were disconnected ( See Figure 1 ).

7) Mount the key switch assembly ( 3A ) to new key switch bracket ( 3B ) as shown.

Mount the key switch and bracket to smaller deck plate ( 3C ) located on top right side of plastic tub. Use the existing hole on smaller deck plate ( 3C ) to mount key switch and bracket with the provided

8-32 self tapping screw ( 3D ). Connect wires previously disconnected to the key switch ( See Figure 3 ).

8) Remove clear film on the adhesive tape located on the back left side ( 4B ) and back right side ( 4C ) of condenser bracket assembly ( 4A ) ( See Figure 4 ).

9) Center condenser bracket assembly ( 5A ) onto air cooled condenser ( 5B ). The bracket should be flush to the bottom side of condenser bracket assembly ( 5A ) to top of air cooled condenser ( 5B ). Press condenser bracket assembly ( 5A ) firmly against air cooled condenser ( 5B ) to adhere adhesive tape. Install the provided

8-32 self tapping countersink screw ( 5C ) through slot in lower left corner of condenser bracket assembly ( 5A ) and into hole in air cooled condenser ( 5B )

( See Figure 5 ).

10) Reinstall the condenser air filter ( 6A ) into the condenser bracket assembly ( 6B ) as shown ( See Figure 6 ).

Revision-1

7B

7C

7D

CEV Metal Bonnet Installation Instructions

Figure 7

4 of 4

7A

Instructions

11) Assemble the metal bonnet assembly

( 7A ) onto CEV unit. The metal bonnet assembly ( 7A ) needs to sit flush on the top cosmetic trim area ( 7B ) of plastic tub and over top of valve mount cap. Align the mounting slots located on front bottom left and right side of metal bonnet assembly ( 7A ) with top mounting slots of valve mount cap. Reinstall the two 8-32 mounting screws ( 7C ) through slots of the metal bonnet assembly and valve mount cap. Install the provided No.8 course thread screw through slot located on top left side ( 7D ) of metal bonnet assembly ( 7A ) and into speed-clip on top of condenser bracket assembly ( See

Figure 7 ).

12) Turn on or reconnect power supply to

CEV unit. Dispense drinks from unit to ensure proper operation before placing unit back into general service.

Part Number 5031540 Revision-1