Midea KJR-120G2 is a wired remote controller for high wall, duct, cassette, and floor ceiling models. It offers precise control over your air conditioning system, allowing you to adjust temperature, fan speed, and other settings from the comfort of your own space. With its intuitive interface and user-friendly design, the Midea KJR-120G2 makes it easy to maintain a comfortable indoor environment, ensuring optimal comfort and energy efficiency.
Advertisement
Advertisement
WIRED REMOTE CONTROLLER
Installation and Owner’s Manual
MODEL:
KJR-120G1/TFBG-E(5V) ( For high wall models )
KJR-120G2/TFBG-E(12V) (For Duct/Cassette/Floor ceiling models)
IMPORTANT NOTE:
Read this manual carefully before installing or operating your wired remote controller. Make sure to save this manual for future reference.
● This manual gives detailed description of the precautions that should
be brought to your attention during operation.
● To ensure the correct service of the wired controller, read this manual
carefully before using the unit.
● Keep this manual after reading for future reference.
CONTENTS
1. SAFETY PRECAUTION....................................................................... 1
2. INSTALLATION ACCESSORY.............................................................. 2
3. INSTALLATION METHOD....................................................................4
4. APPENDIX INSTALL THE WIRE CONTROLLER KIT...............................10
5. SPECIFICATION...............................................................................16
6. WIRED CONTROLLER FEATURES AND FUNCTIONS...........................17
7. WIRED CONTROLLER DISPLAY.........................................................18
8. WIRED CONTROLLER BUTTONS.......................................................19
9. PREPARATORY OPERATION..............................................................20
10. OPERATION...................................................................................21
11. TIMER FUNCTIONS........................................................................27
12. WEEKLY TIMER.............................................................................30
13. FAULT ALARM HANDING..............................................................37
14.TECHNICAL INDICATION AND REQUIREMENT ...............................37
1. SAFETY PRECAUTION
Read the safety precautions carefully before installing the unit.
Stated below are important safety issues that must be obeyed.
WARNING Means improper handling may lead to personal death or severe injury.
CAUTION Means improper handling may lead to personal injury or property loss.
WARNING
Please entrust the distributor or professionals to install the unit.
Installation by other persons may lead to imperfect installation, electric shock or fire.
Adhere to this installation manual.
Imporper installation may lead to electric shock or fire.
Reinstallation must be performed by professionals.
Do not uninstall the unit randomly.
Random uninstalling may lead to abnormal operation, heating or fire of the air condition.
NOTE
1
2
3
4
Do not install the unit in a place vulnerable to leakage of flammable gases.Once flammable gases are leaked and left around the wire controller, fire may occure.
Do not operate with wet hands or let water enter the wire controller. Otherwise, electric shock may occur.
The wiring should adapt to the wire controller current. Otherwise, electric leakage or heating may occur and result in fire.
The specified cables shall be applied in the wiring. No external force may be applied to the terminal. Otherwise, wire cut and heating may occur and result in fire.
1
2. INSTALLATION ACCESSORY
Select the installation location
Don’t install at the place where cover with heavy oil, vapor or sulfureted gas, otherwise, this product would be deformed that would lead to system malfunction.
Preparation before installation
1. Please confirm that all the following parts you have been supply.
No.
1
6
7
4
5
2
3
8
Name
Wire controller
Installation and owner’s manual
Screws
Wall plugs
Screws
Plastic screw bars
Battery
The connection cable
Qty.
1
1
3
3
2
2
1
1
Remarks
M4X20 (For Mounting on the Wall)
For Mounting on the Wall
M4X25 (For Mounting on switch box)
For fixing on switch box
(Optional)
2. Prepare the following assemblies on the site.
No.
1
Name
Qty.(embeded into wall)
Specification
(only for reference)
1
2
Switch box
Wiring Tube(Insulating
Sleeve and Tightening
Screw)
1
Remarks
2
2. INSTALLATION ACCESSORY
WIRED CONTROLLER INSTALLATION PRECAUTION
1. This manual provides the wired controller installation method. Refer
to the wiring diagram in this installation manual to wire the wired
controller with the indoor unit.
2. The wired controller works in a low voltage loop circuit. Do not
connect directly to 208/230V and 460V. Do not wire this kind of wire
into a loop. Wiring clearance between the configured tubes should
range 11.81−19.69 inches (30−50 cm) or above.
3. The shielded wire of the wired controller must be properly grounded.
4. Upon finish the wire controller connection, do not employed
tramegger to detect the insulation.
3
3. INSTALLATION METHOD
1.Wired Remote Controller Dimensions
120mm
(4.7”)
18.5mm
(0.7”)
46mm
(1.8”)
123mm
(4.8”)
83.5mm
(3.3”)
62mm
(2.4”)
Fig 3-1
4
2.Wiring Connection Diagram red black yellow brown
Wire controller
-----------------------------------
-----------------------------------
-----------------------------------
-----------------------------------
4-Core Shield Cable, the length is decided by installation
Fig 3-2
Insert of the mainboard CN40 red black yellow brown
Indoor unit mainboard
3. INSTALLATION METHOD
3.Wiring figure
Mainboard
4-core shielding wire
The connection cable
CN40
Model A: KJR-120G2/TFBG-E(12V)
Fig 3-3(A)
Connect the female joint of the wires group from the mainboard
with the male joint of the connective wires group. (See Fig.3-3(A))
Connect the other side of the connective wires group with the male
joint of the wires group leads from the wire controller.(See Fig.3-3(A))
Display board
Adapter board
The connection cable
CN101
4-core shielding wire
Model B: KJR-120G1/TFBG-E(5V) Fig 3-3(B)
5
3. INSTALLATION METHOD
Install the Adapter Board and the Display Board on the High Wall
(See the Appendix for instructions).
Connect the female joint of the wires group from the adapter board with the male joint of theconnective wires group. Next, connect the other side of the adapter board with the displayboard. (See Fig.3-3(B))
Connect the other side of the connective wires group with the male joint of the wires group leads from the wire controller. (See Fig.3-3(B))
4.Wire controller upper part Remove
Insert a flat screwdriver into the slots in the lower part of the wire controller (2 places).
Remove the upper part of the wire controller
(Fig.3-4)
NOTE: The PCB is mounted in the upper part of the wired controller. Be careful not to damage the board with the screwdriver.
Slots
Fig 3-4
5. Fasten the wire controller back plate
For surface mounting, fasten the back plate on the wall with the 3 screws (M4x20) and plugs. (Fig.3-5)
Back plate
Screws (M4×20)
Fig 3-5
6
3. INSTALLATION METHOD
For switch box mounting, fasten the back plate on the switch box with
2 screws (M4x25) and fasten it on the wall with 1 screw (M4x20).
(Fig.3-6)
Back plate Switch box
Screw (M4×20)
Screws (M4×25)
Fig 3-6
NOTE: Place on a flat surface. Be careful not to distort the wire controller’s back plate by over−tightening the mounting screws.
6. Battery installation
Fig 3-7
Place the battery in the unit and ensure the positive side of the battery is in accordance with the polarity markings.(See Fig.3-7)
Set the correct time before operating. Batteries in the wired controller can maintain the correct time during a power failure. When the power is restored and the displayed time is not correct, replace the battery.
7
3. INSTALLATION METHOD
7. Wire the indoor unit
There are three methods:
1 from the rear;
2 from the bottom;
3 from the top;
1
PCB
3
PCB
2
PCB
1
1
8
4. Notch the part for the wiring to pass through with a nipper tool.
3. INSTALLATION METHOD
NOTE: DO NOT allow water to enter the remote control.
Use the trap and putty to seal the wires.
Putty
Trap
Putty
Putty
Trap
Trap
Fig 3-8
8. Reattach the wire controller’s upper part
While adjusting and mounting the upper case, avoid clamping the wiring during installation. (Fig 3-9)
Fig 3-9
IMPORTANT: All the pictures in this manual are for illustration purposes only.
Your wire controller may differ slightly.
9
4. APPENDIX
INSTALL THE WIRE CONTROLLER KIT
1. Open the front panel.
2. Disconnect the wire from the main controller board.
10
4. APPENDIX
INSTALL THE WIRE CONTROLLER KIT
3. Identify the components. From left to right, the wired controller,
convert board and the display board.
4. Identify connections on the Display Board.
CN201 is the display board connection to the main board wire
(on the display board).
11
4. APPENDIX
INSTALL THE WIRE CONTROLLER KIT
CN101 is the display board connection to the convert board wire
(on the display board).
5. Uninstall the display board from the front panel. Keep the display
board holder.
12
4. APPENDIX
INSTALL THE WIRE CONTROLLER KIT
6. Carefully bend and break off the rectangular section (upper left
section with two diagonal holes) from the display board.
NOTE: Break off the upper left hand rectangle (section with the two holes marked with a red rectangle).
7. Replace the old display board (for the New Display board provided)
and secure with the clips. To uninstall the clips, push the clips inward.
NOTE: There are 4 clips just above the numeric display (88) which run the length of the holder.
13
4. APPENDIX
INSTALL THE WIRE CONTROLLER KIT
8. Before assembling mounting back on the Front Panel, remove the
display board’s screen cover.
9. Connect the Wires to the Adaptor Board.
a. Connect the wire coming from the Display board to the Convert
Board (this connection consists of 5 wires).
14
4. APPENDIX
INSTALL THE WIRE CONTROLLER KIT b. Connect the wire coming from the Wired Remote Controller to
the Convert Board (this connection consists of 4 wires).
10. Once the ports are connected, install the cover.
11. Mount the new display board and convert board to the Front Panel.
12. Connect the wired remote controller to the display board and the
convert board.
13. Connect the wire from the main controller board (see Fig 3-2).
15
5. SPECIFICATION
Input voltage
Ambient temperature
Ambient humidity
DC 5V/DC 12V
23~110 ℉( -5~43 ℃)
RH40%~RH90%
Wiring specifications
Wiring type
Shielded vinyl cord or cable
Size
0.029 in-0.74mm
Total length
<66 ft (20m)
<164 ft (50m)
16
6. FEATURE AND FUNCTION OF THE WIRED
CONTROLLER
Swing Timer
-
Day off/Del Confirm Back/Turbo
℃
Copy/
Follow me
℉
Mode
+
Fan speed
(Lock)
Feature:
LCD display.
Malfunction code display: displays the error code (helpful for servicing)
4-way wire layout design.
Room temperature display.
Weekly Timer
MODEL: KJR-120G2/TFBG-E(12V)
Swing Timer Day off/Del Confirm Back/Turbo
℃
Copy/
Follow me
℉
Mode
+
Fan speed
(Lock)
MODEL: KJR-120G1/TFBG-E(5V)
Function:
Mode: choose Auto-Cool-Dry-Heat-Fan
Fan speed: Auto-Low-Med-High
Swing(on some models)
Timer ON/OFF
Temp setting
Weekly Timer
Follow me
Child Lock
LCD Display
Clock
Panel function (on some models)
17
7. WIRED CONTROLLER DISPLAY
1 2 3 4 5 6 7 8
15
1. Operation mode indicator
2. Fan speed indicator
3. Left-right swing indicator
4. Up-down swing indicator
5. Faceplate function indicator
6. Main unit and secondary unit
indicator
7. Follow me function indicator
18
14
8. Turbo/Auxiliary Heat function indicator
9. °C / °F indicator
10. Temperature display
11. Lock indicator
12. Room temperature indicator
13. Clock display
14. On/Off timer
15. Timer display
9
10
11
12
13
8. WIRED CONTROLLER BUTTONS
5
6
7
3
1. Mode
2. Power
3. Adjust
4. Fan Speed
5. Swing
Swing Timer Day off/Del Confirm Back/Turbo
Copy/
Follow me
Mode
+
Fan speed
(Lock)
6. Timer
7. Day Off/Del
8. Copy/Follow me
9. Back/Turbo
10. Confirm
2
3
8
9
10
1
4
19
9. PREPARATORY OPERATION
Set the current day and time
1
Timer
Press TIMER for 3s or more. The timer displays flashes.
2
+
Press + or − to set the date. The selected date flashes.
3
Timer
4
-
Date setting is complete and the time setting is ready after pressing TIMER or if nothing is pressed in 10 seconds.
+
Press + or − to set the current time. Press repeatedly to adjust the current time in 1 minute increments.
Press and hold to adjust the current time.
5
20
Timer ex.Monday AM 11:20
The setting is complete after pressing TIMER or if no button is pressed for 10 seconds.
10. OPERATION
To start/stop operation
Press the Power button.
To set the operation mode
Operation mode setting
Mode
Press MODE to set the operation mode.
(Heat function is invalid for cool only type unit)
Room temperature setting
+
Press + or − to set the room temperature. Indoor
Setting Temperature Range:
62~86 ℉ (17~30 ℃ )/62~88 ℉ (17~31 ℃ (depending on models)).
Lower Raise
21
10. OPERATION
Fan speed setting
Press FAN SPEED to set the fan speed
NOTE: This function is unavailable in the AUTO or DRY
modes.
Fan speed
(Lock)
Room temperature sensor selection
Press FOLLOW ME to select whether the room temperature is detected at the indoor unit or at the wired controller.
Copy/
Follow me
Indoor Unit
22
NOTE: When the FOLLOW ME function indication appears, the room temperature is detected at the wire remote controller.
10. OPERATION
Child lock function
Fan speed
(Lock)
Press LOCK for 3 seconds to activate the
CHILD LOCK feature and lock all buttons on the wired controller. Press again for 3 seconds to deactivate.
NOTE: When the child lock function is activated, the lock image appears.
keypad tone setting
Swing Timer
Press SWING and TIMER simultaneously for 3 seconds to disable the keypad tone. Press the buttons again for 3 seconds to enable the keypad tone.
°C & °F scale selection (on some models)
Back/Turbo
℃
Copy/
Follow me
℉
Press BACK and COPY simultaneously for 3 seconds to alternate the temperature display between the ℉ & ℃ scale.
23
10. OPERATION
Turbo/Auxiliary Heat function (on some models)
Back/Turbo
•
•
•
Press TURBO to activate/deactivate the Turbo/Auxiliary
Heat function. The turbo function sets the unit to reach the user’s present temperature in the shortest amount of time possible.
When the user presses TURBO in the COOL mode, the unit sets to the highest fan speed setting to jump−start the cooling process.
When the user presses TURBO in the HEAT mode, for units with AUX. HEAT, the AUX. HEAT activates and jump−starts the heating process.
Lift panel function (only for some cassette specific panel)
Mode
1.When the unit is off , Press the Mode button long to
activate the lift panel function.The mark will flash.
The F2 mark appears when the panel is adjusted.
2. Press the button + and to control the lift and drop of the panel.
Pressing the + button can stop the panel,while it is dropping.
Pressing the button can stop the panel,while it is lifting.
24
10. OPERATION
Swing function
(For the unit with left & right auto swing function only)
1 Up-Down swing
Swing
Press the Swing button to start up-down swing function.
Press it again to stop.
When the Up-Down swing function is activated,the mark appears.
2 Left-Right swing
Swing
Press the Swing button long to start Left-Right swing function.
Press it again to stop.
When the Left-Right swing function is activated, the mark appears.
25
10. OPERATION
Swing function
(For the unit without left & right auto swing function models)
Up-Down airflow direction and swing
Swing
Use SWING to adjust the up and down airflow direction.
1.Every time the user presses SWING , the louver swings six degrees.
2.Press and hold SWING for 2 seconds, it changes to the
UP−DOWN SWING mode. Press SWING again to stop.
When the Up-Down swing function is activated,the mark appears.
(Not applicable to all the models)
The operation can refer to the following instructions for the unit with four Up-Down louvers can be operated individually.
1.Press the Swing button to activate the Up-Down
adjusting louver function.
The mark will flash.(Not applicable to all the models)
Swing
2.Pressing the button “ + ” or“ ” can select the movement
of four louvers.Each time you push the button,the wire
controller select in a sequence that goes from:(the icon
+
-0 -1 -2 -3 -4
26
3. And then use Swing button to adjust the Up-Down airflow direction
of the selected louver.
11. TIMER FUNCTIONS
WEEKLY timer
Use to set the operating times for each day of the week.
On timer
Use to start the air conditioner operation. The timer operates and the air conditioner operation starts after the time has passed.
Off timer
Use to stop the air conditioner operation. The timer operates and the air conditioner operation stops after the time has passed.
On and Off timer
Use to start and stop the air conditioner operation. The timer operates and the air conditioner operation starts and stops after the time has passed.
27
11. TIMER FUNCTIONS
To set the On or Off TIMER
1
Timer
Press Timer to select the or .
No display
2
Confirm
Press Confirm and the Clock display flashes
3
-
4
Confirm
+ ex.Off timer set at PM 6:00
Press + or − to set the time. After the time is set, the timer starts or stops automatically.
Press Confirm again to finish the settings.
28
11. TIMER FUNCTIONS
To set the On and Off TIMER
1
Timer
Press Timer to select the .
2
Confirm Press Confirm and the Clock display flashes.
3
-
4
-
Confirm
+
Press the button + or to set the On timer and then press Confirm .
Press + or - to set the Off timer .
+
5
Confirm
Press Confirm to finish the setting.
29
12. WEEKLY TIMER
1
Weekly timer setting
Press Timer to select the and press Confirm .
Timer Confirm
2
Day of the week setting
Press + or − to select the day of the week and then press CONFIRM .
+
Confirm
3
ON timer setting of timer setting 1
+
Confirm Press + and − to select the setting time.
The setting time, mode, temperature and fan speed appear on the LCD. Press
CONFIRM to enter the setting time process.
30
12. WEEKLY TIMER
IMPORTANT: Up to 8 scheduled events can be set on one day. Various events can be scheduled in either MODE,
TEMPERATURE and FAN speeds.
4
Time setting
Confirm
+ ex.Tuesday time scale 1
Press + and − to set the time then press
CONFIRM .
5
Operation mode setting
+
Confirm
Press + and − to set the operation mode then press CONFIRM .
6
Room temperature setting
+
Confirm
Press + and − to set the room temperature then press CONFIRM .
NOTE: This setting is unavailable in the FAN or OFF modes.
31
12. WEEKLY TIMER
7
Fan speed setting
Press + and − to set the fan speed then press
Confirm
CONFIRM .
+
NOTE: This setting is unavailable in the AUTO,
DRY or OFF modes.
8
9
Different scheduled events can be set by repeating steps 3 through 7.
Additional days, in a one week period, can be set by repeating steps 3 through 8.
32
NOTE: The weekly timer setting can be returned to the previous step by pressing BACK . The current setting is restored. The controller will not save the weekly timer settings if there is no operation within 30 seconds.
12. WEEKLY TIMER
WEEKLY timer operation
To start
Press Timer to select the , and then the timer
Timer starts automatically.
ex.
To cancel
Press Power to cancel the timer mode.
Timer
The timer mode can also be canceled by changing the timer mode using Timer .
To set the DAY OFF (for a holiday)
1
Confirm
After setting the weekly timer, press CONFIRM .
2
+
Press + or − to select the day of the week.
33
12. WEEKLY TIMER
Press DAY OFF to create an off day.
3
Day off/Del
The mark is hidden
4
5
Back/Turbo ex.The DAY OFF is set for Wednesday
Set the DAY OFF for other days by repeating the steps
2 and 3.
Press BACK to revert to the weekly timer.
● To cancel, follow the same procedures used for setup.
● NOTE: The DAY OFF setting is cancelled automatically after the set
day has passed.
Copy out the setting in one day into the other day.
● A scheduled event, made once, can be copied to another day of the
week. The scheduled events of the selected day of the week will be
copied. The effective use of the copy mode ensures the ease of
reservation making.
1 Confirm
In the weekly timer, press CONFIRM .
2
34
+
Press + or − to select the day to copy from.
12. WEEKLY TIMER
3 Copy/
Follow me
Press COPY , the letters CY appear on the LCD.
4
+
Press + or − to select the day to copy to.
5 Copy/
Follow me
Press COPY to confirm.
The mark flashes quickly
6
7
Confirm ex. Copy the setting of Monday to Wednesday
Other days can be copied by repeating steps 4 and 5.
Press CONFIRM to confirm the settings.
8
Back/Turbo
Press BACK to revert to the weekly timer.
35
12. WEEKLY TIMER
Delete the time scale in one day.
1
Confirm
During the weekly timer setting, press CONFIRM.
2
Confirm
Press + and − to select the day of the week and then press CONFIRM .
+
3
+
Day off/Del
Press + and − to select the setting time want to delete. The setting time, mode, temperature and fan speed appear on the LCD. The setting time, mode, temperature and fan speed can be deleted by pressing the DEL
(day off).
ex. Delet the time scale 1 in saturday
36
13. FAULT ALARM HANDING
If the system does not properly operate except in the aforementioned cases or the aforementioned malfunctions are evident, investigate the system according to the following procedures.
NO.
MALFUNCTION AND PROTECTION DEFINITION
1
Communication error between wired controller and indoor unit
2 The faceplate is abnormal
DISPLAY
DIGITAL TUBE
F0
F1
Please check the indoor unit’s error display and review the owner’s manual if other error codes appear.
14.TECHNICAL INDICATION AND REQUIREMENT
EMC and EMI comply with the CE certification requirements.
37
QSXUI-009AEN
The design and specifications are subject to change without prior notice for product improvement.Consult with the sales agency or manufacturer for details.
16117100A02776
20160312

Download
Advertisement
Key features
- Precise temperature control for optimal comfort
- Versatile compatibility with various air conditioning models
- User-friendly interface for easy operation
- Weekly timer for automated climate control
- Fault alarm handling for timely troubleshooting