SCS30

Solar Powered

Hanging Scale

Operation Manual

Cardinal Scale Manufacturing Co.

8551-0967-0M Rev E 203 E. Daugherty, Webb City, MO 64870 USA

04/18 Ph: 417-673-4631

Fax: 417-673-2153 www.detecto.com

8551-0967-0M Rev E  SCS30 Operation

SPECIFICATIONS

Power: Solar Cell (min. 400 LUX)

Operating Temperature: 32 to 104º F (0 to 40 º C)

Display:

Annunciators:

Five digit, seven segment, 1.0 inch (25 mm) high LCD lb, kg,  (Zero), (Solar Charge Status)

Capacity: 30lb x 0.01 lb (15kg x 0.005kg)

NTEP:

UNPACKING

Class III , Certificate of Conformance Number 15-009

Before beginning installation of your scale, make certain it has been received in good condition. When removing the scale from its packing, inspect it for signs of damage, such as exterior dents and scratches. Keep the carton and packing material for return shipment if it should become necessary. It is the responsibility of the purchaser to file all claims for any damages or loss incurred during transit. You should have the following items:

(1) SCS30 Scale

(2) Carabiners

(1) Bow Assembly

(1) Ring Assembly

(2) Pan Bow Nuts

(2) Wing Nut 5/16-18

(1) Pan

SETUP

1. Insure that the light available is adequate to power the scale (typically an average lighted room is 400

LUX. This is adequate to power the scale.

NOTE: Make sure nothing is shading the solar cell from the available light. Low lighting will result in the scale display showing Lo .

2. Referring to Figure No. 1, install a carabiner on top loop of scale.

3. Hang scale from a support that is strong enough to support the scale PLUS the weight of the item to be weighed.

4. Follow the Hanging Assembly instructions to compete the required assembly.

5. The scale has been calibrated with the enclosed hanging assembly. In order to display zero, the hanging assembly must be attached.

6. Scale is now ready to use.

Figure No. 1

WARNING! Failure to attach the scale to a support of sufficient strength using a connector to hold the scale PLUS the weight of the item to be weighed can result in the scale coming loose and damaging the scale and/or injuring the operator and persons nearby.

1 8551-0967-0M Rev E  SCS30 Operation

HANGING ASSEMBLY

The SCS30 is shipped with a bow and pan hanging assembly. The hanging assembly is made up of four (4) main components.

Carabiner

Bow

Ring and bow attachment hardware (Pan Bow

Nuts and 5/16-18 Wing Nuts)

Pan

Bow

Carabiner

Assemble the hanging assembly as illustrated in

Figure No. 2. The hanging assembly is then attached to the lower loop on the scale. Place pan in Ring.

Pan Bow Nut

OPERATION

5/16-18 Wing Nut

Ring

1. Hang scale from a secure position with minimum 400 LUX lighting level. Make sure nothing is shading the solar cell from the available light.

Calibration

Seal

Figure No. 2

Pan

Zero

Button

2. Referring to Figure No. 3, press Zero Button to zero scale.

3. To change between units (lb to kg or kg to lb), press and hold Zero Button for approximately

5 seconds.

4. Place item to be weighed in pan.

Figure No. 3

5. Display will show weight of item.

6. Remove product and press Zero Button if required before weighing next item.

NOTE: If scale is not weighing full capacity and ERR is displayed, with hanging assembly and pan to be used with scale, press and hold Zero Button for 10 seconds to reset scale.

DO’S AND DON’TS

DO hang scale from a support that is strong enough to support the weight of the scale

PLUS the weight of the material to be weighed. The more rigid the support the better.

DO ensure that the scale is not shaded from the available light.

DO avoid shock loading the scale, i.e. do not drop heavy loads in the pan.

DO check the hanging assembly wing nuts on a regular basis to ensure they are tight.

DO check on a regular basis the scale’s supporting hardware to ensure that it continues to provide the strength necessary to support the weight of the scale PLUS the item to be weighed.

DO NOT spray; water directly on the scale.

DO clean scale using a damp, soft cloth and mild detergent.

DO NOT use acetone, alcohol, or other volatile solvents for cleaning.

8551-0967-0M Rev E  SCS30 Operation 2

CALIBRATION

NOTE: Calibration must be performed under plenty of light with hanging assembly and pan to be used with scale.

1. Remove the calibration seal to expose the Test Pins.

See Figure No. 3 on previous page for seal location.

2. Referring to Figure No. 4, short Test Pins 3-4 to enter calibration mode. The display will show the internal count (zero count) when in the calibration mode.

(Ple ase note “kg” or “lb” unit for selecting the calibration weight).

3. Press Zero Button to set calibration ZERO.

4. Place 15kg or 30lb test weight in pan and wait for scale weight to stable.

5. Press Zero Button to set calibration SPAN.

6.  will be displayed for approximately 3-5 seconds.

7. After calibration is finished, scale will automatically return to Normal Mode and display will show

15kg/30lb.

Figure No. 4

1.

From Normal Mode Display, short Test Pins 3-4

Zero Count Displayed

Normal Mode Display

2.

Press Zero Button to set calibration ZERO

3.

Place test weight on scale

4.

Press Zero Button to set calibration SPAN

5.

CAL will be displayed

(Wait 3~5 seconds)

3

6.

Scale will return to Normal

Mode and display calibration test weight.